-PLEASE CONTACT FOR CUSTOM CONFIGURATIONS. DISK SHELVES, COMPLETE CONFIGURATIONS & TURN KEY SYSTEMS AVAILABLE.
-SPARE PARTS AVAILABLE FOR EACH MODEL. PLEASE ASK FOR PRICING ON SPARE DISK, CONTROLLERS, POWER SUPPLIES, NICs, HBAs, SFPs, Cables, etc.
- (4) Intel Xeon E7-4800/8800 v2
- (96) DDR3 RDIMM & LRDIMM slots
- (9) PCIe Gen3.0 slots
- Supports up to (10) Drives
- Supports up to (4) PSUs
- Supports up to (5) GPUs
- Supports 12Gbps SAS
- Embedded HPE Smart Array 12Gb P830i Controller with FBWC
- New flexible network technology - FlexibleLOMs
The refurbished HPE ProLiant DL580 Gen8 Server is an Enterprise-Grade four socket (4S) x86 server offering break through performance, Rock-Solid reliability, and compelling consolidation and manageability efficiencies. It is ideal for Mission-Critical enterprise, business intelligence, and database applications.
Featuring Intel Xeon E7-4800/8800 v2 processors, the DL580 Gen8 offers blazing fast results with enhanced processor performance, more memory slots (96 DIMMs), greater IO bandwidth (9 PCIe Gen3.0 slots), and increased storage performance (12 Gbps SAS).
- Cloud Servers
- Corporate IT
- Database
Configure your DL580 — drives, RAID, rails, and warranty.
Talk to a sales expert today.
Build Your Refurbished DL580 →
Specs 1
Software overview
Feature | Description |
|---|---|
OS and virtualization software support for ProLiant servers |
|
Softwares |
|
Physical specifications
Specifications | Description |
|---|---|
Dimensions (H x W x D) (with bezel) | 17.6 x 48.3 x 70.0 cm (6.94 x 19.0 x 27.55 in) |
Weight (approximate) |
|
Electrical specifications
Specifications | Description |
|---|---|
Input requirements (per power supply) | |
Rated line voltage |
|
Rated input current |
|
Rated input frequency | 50 to 60 Hz |
Rated input power |
|
BTU rating | |
Maximum |
|
Power supply output (per power supply) | |
Rated steady-state power |
|
Maximum peak power |
|
Environmental specifications
Specifications | Description |
|---|---|
System inlet temperature | |
Operating | 10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 304.8 m (1.8°F per every 1000 ft) above sea level to a maximum of 3048 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). |
Non-operating | -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). |
Relative humidity (non-condensing) | |
Operating | 10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing. |
Non-operating | 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing. |
Altitude | |
Operating | 3048 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). |
Non-operating | 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). |
Acoustic noise 1 | |
Idle |
|
Operating |
|
NOTE: 1.Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements. | |
Safety certifications
Certifications | Description |
|---|---|
Emissions Classification (EMC) | |
FCC rating | Class A |
Normative standards | CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 |