Base Standard Capabilities
Product features
Feature | Description | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Processor (One or more of the following depending on model) | Fifteen-Core processors 1
Twelve-Core processors 2
Ten-Core processors 3
Eight-Core processors Intel Xeon E7-4820v2 (2.0 GHz/8-core/16MB/105 W) processor Six-Core processors 3
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cache memory (One of the following depending on model) |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Chipset 4 |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Upgradeability 5 |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Memory 6 (One of the following depending on model) |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
System fault management and diagnostics |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
FlexibleLOM 7 |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Expansion slots 8 |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Storage controller 9 (One of the following depending on model) | HPE Smart Array P830i/2G Flash Backed Write Cache (FBWC) Controller The FBWC increases cache data retention capabilities from two days of existing Battery Backed Write Cache (BBWC) to infinite data retention.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Internal storage devices |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Maximum internal storage |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Interfaces |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Common slot power supply 10 (One of the following depending on power requirements) |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
System fans | 4 Hot-Plug fans (Eight rotors with N+1 redundancy) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Graphics | Integrated Matrox G200 video standard
HPE iLO 4 On system management memory
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Form factor | 4U rack | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Security |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Industry standard compliance 11 |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
HPE Server Unified Extensible Firmware Interface (UEFI) ROM 12 | UEFI enables numerous new capabilities, including both industry standard functionality and features specific to HPE ProLiant servers. Following are some of the features that UEFI enables and that the HPE ProLiant DL580Gen8 can support when configured for UEFI boot operation:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
More Specs
Software overview
Feature | Description |
---|---|
OS and virtualization software support for ProLiant servers |
|
Softwares |
|
Physical specifications
Specifications | Description |
---|---|
Dimensions (H x W x D) (with bezel) | 17.6 x 48.3 x 70.0 cm (6.94 x 19.0 x 27.55 in) |
Weight (approximate) |
|
Electrical specifications
Specifications | Description |
---|---|
Input requirements (per power supply) | |
Rated line voltage |
|
Rated input current |
|
Rated input frequency | 50 to 60 Hz |
Rated input power |
|
BTU rating | |
Maximum |
|
Power supply output (per power supply) | |
Rated steady-state power |
|
Maximum peak power |
|
Environmental specifications
Specifications | Description |
---|---|
System inlet temperature | |
Operating | 10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 304.8 m (1.8°F per every 1000 ft) above sea level to a maximum of 3048 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). |
Non-operating | -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). |
Relative humidity (non-condensing) | |
Operating | 10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing. |
Non-operating | 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing. |
Altitude | |
Operating | 3048 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). |
Non-operating | 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). |
Acoustic noise 1 | |
Idle |
|
Operating |
|
NOTE: 1.Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements. |
Safety certifications
Certifications | Description |
---|---|
Emissions Classification (EMC) | |
FCC rating | Class A |
Normative standards | CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 |