VCV6T - Dell PERC 11 H355i FH RAID Controller

Quick Specs
Models

PCIe Adapter PERC

Drive Types

12 Gb/s SAS
6 Gb/s SAS/SATA

PCI Support

PCI-e 4.0

SAS Connectors

16 ports-2x8 Internal

Cache Memory

No Cache

Write Back Cache

No Cache

RAID Levels

0,1,10

Max Drive Support

Up To 32 RAID, or 32 Non-RAID

RAID Support

Hardware

Part Numbers:
  • VCV6T
H355 PERC Series 11 Options

H355 Adapter
View PERC

Enclosures per port

0

Cache:

N/A

RAID Level:

0, 1, 10

PCIe:

Gen 4

Supported Drives:
  • 12 Gb/s SAS
  • 6 Gb/s SAS/SATA
Max SAS/SATA disks:
  • Up To 32 RAID
  • or 32 Non-RAID
Max NVMe drives:
  • Not Supported
Max physical disks:
  • N/A

H355 Front
View PERC

Enclosures per port

0

Cache:

N/A

RAID Level:

0, 1, 10

PCIe:

Gen 4

Supported Drives:
  • 12 Gb/s SAS
  • 6 Gb/s SAS/SATA
Max SAS/SATA disks:
  • Up To 32 RAID
  • or 32 Non-RAID
Max NVMe drives:
  • Not Supported
Max physical disks:
  • N/A
Summary of RAID levels
Summary of RAID levels Following is a list of the RAID levels supported by the PERC 12 series of cards:
  • RAID 0 Uses disk striping to provide high data throughput, especially for large files in an environment that requires no data redundancy.
  • RAID 1 Uses disk mirroring so that data written to one physical disk is simultaneously written to another physical disk. RAID 1 is good for small databases or other applications that require small capacity and complete data redundancy.
  • RAID 5 Uses disk striping and parity data across all physical disks (distributed parity) to provide high data throughput and data redundancy, especially for small random access.
  • RAID 6 Is an extension of RAID 5 and uses an additional parity block. RAID 6 uses block-level striping with two parity blocks distributed across all member disks. RAID 6 provides protection against double disk failures, and failures while a single disk is rebuilding. If you are using only one array, deploying RAID 6 is more effective than deploying a hot spare disk.
  • RAID 10 Is a combination of RAID 0 and RAID 1, uses disk striping across mirrored disks. It provides high data throughput and complete data redundancy.
  • RAID 50 Is a combination of RAID 0 and RAID 5 where a RAID 0 array is striped across RAID 5 elements. RAID 50 requires at least six disks.
  • RAID 60 Is a combination of RAID 0 and RAID 6 where a RAID 0 array is striped across RAID 6 elements. RAID 60 requires at least eight disks.
Compatible With:
  • Dell R250
  • Dell R350
  • Dell R660
  • Dell R660xs
  • Dell R6615
  • Dell R6625
  • Dell R760
  • Dell R760xa
  • Dell R760xd2
  • Dell R760xs
  • Dell R7615
  • Dell R7625
  • Dell R860
  • Dell R960
  • Dell T150
  • Dell T350
  • Dell XR12
  • Dell XR5610

(Click to View)