Dell PERC 11 H755 SAS 12Gb FH RAID Controller | 29XMF

Quick Specs
  • Models: PCIe Adapter PERC
  • Drive Types: Gen3 (8 GT/s) NVMe, Gen4 (16 GT/s) NVMe, 12 Gb/s SAS, 6 Gb/s SAS/SATA, 3Gb/s SAS/SATA
  • PCI Support: PCI-e 4.0
  • SAS Connectors: 16 Port 2x8 Internal
  • Cache Memory: 8GB NV
  • Write Back Cache: Flash Backed Cache
  • Max Drive Support: 16/controller, 50 with SAS Expander (Platform limit)
  • RAID Levels: 0, 1, 5, 6, 10, 50, 60
  • RAID Support: Hardware
Part Number:
  • LP: 51P7W
  • FH: 29XMF
  • fPERC: 3KDWX
  • MX: XYHRD
The Dell PERC 11 H755 SAS 12Gb RAID Controller FH provides high-performance storage management for servers utilizing NVMe and SAS/SATA drives. With PCI-e 4.0 support and a 16-port 2x8 internal connector, it delivers robust data throughput and flexibility for large enterprise deployments.

Featuring 8GB of non-volatile cache and flash-backed cache protection, the H755 supports a broad range of RAID levels including 0, 1, 5, 6, 10, 50, and 60. With scalable drive support and high-speed Gen3 and Gen4 NVMe compatibility, it meets the demands of performance-intensive storage environments.
Summary of RAID levels
Summary of RAID levels Following is a list of the RAID levels supported by the PERC 12 series of cards:
  • RAID 0

    Uses disk striping to provide high data throughput, especially for large files in an environment that requires no data redundancy.

  • RAID 1

    Uses disk mirroring so that data written to one physical disk is simultaneously written to another physical disk. RAID 1 is good for small databases or other applications that require small capacity and complete data redundancy.

  • RAID 5

    Uses disk striping and parity data across all physical disks (distributed parity) to provide high data throughput and data redundancy, especially for small random access.

  • RAID 6

    Is an extension of RAID 5 and uses an additional parity block. RAID 6 uses block-level striping with two parity blocks distributed across all member disks. RAID 6 provides protection against double disk failures, and failures while a single disk is rebuilding. If you are using only one array, deploying RAID 6 is more effective than deploying a hot spare disk.

  • RAID 10

    Is a combination of RAID 0 and RAID 1, uses disk striping across mirrored disks. It provides high data throughput and complete data redundancy.

  • RAID 50

    Is a combination of RAID 0 and RAID 5 where a RAID 0 array is striped across RAID 5 elements. RAID 50 requires at least six disks.

  • RAID 60

    Is a combination of RAID 0 and RAID 6 where a RAID 0 array is striped across RAID 6 elements. RAID 60 requires at least eight disks.

Compatible With:
  • Dell R350
  • Dell R660
  • Dell R660xs
  • Dell R6615
  • Dell R6625
  • Dell R750
  • Dell R750xs
  • Dell R7525
  • Dell R760
  • Dell R760xa
  • Dell R760xd2
  • Dell R760xs
  • Dell R7615
  • Dell R7625
  • Dell R860
  • Dell R960
  • Dell T150
  • Dell T350
  • Dell XR12
  • Dell XR5610

(Click to View)