Dell PowerEdge R7615 Rack Server | Configurable

 

READ ME

  • Some options may not be displayed until the compatible parent option is chosen ie. Chassis – Drives, Processor – RAM etc.
  • “Quote” items can be added to your cart and sent to us via the cart page
  • Click the blue bar to close/open a section from view after choosing your options

Select Chassis

The reason you don’t see a 16SFF Chassis is because both 8SFF Chassis support extra backplanes being installed. Both chassis will support either the Universal or the NVMe 8SFF Backplanes. It's okay to Mix and Match. Up to 16 or 24 total drives.
Check Cable Routing for more detailed information in the manual below.

Select Processor

Supports up to 1 Processor

AMD 4th Gen 9004

Supports up to 1 Processor

Drive cage (Optional)

Rear drive chages only supported by 2 chassis.

Backplanes (Optional)

Only supported on the 8SFF Chassis.
Backplanes to expand the drives on the chassis.

Heat sinks / Fans / Cooling Modules (Optional)

If any GPUs are installed the Fan, and Heat Sink will need to be upgraded.
Depending on the TDP of the CPU, you might need to upgrade the Cooling from Air-cooled to DLC.
For all thermal-related inquiries please refer to the "Thermal Matrix" in the manuals below.

Memory

Supports up to 12 DIMMs

Storage Devices (Optional)

LFF SATA Drives (Optional)

Supports up to 8 or 12 Drives

LFF SATA Drives (Optional)

Supports up to 8 or 12 Drives

SFF SAS Drives (Optional)

Supports up to 24 drives or 2 Rear drive depending on the configuration.

SFF SATA Drives (Optional)

Supports up to 24 drives or 2 Rear drive depending on the configuration.

NVMe Drives (Optional)

Supports up to 24 Front drives or up to 4 Rear drives

EDSFF E3.S Drives (Optional)

Supports up to 32 Drives

PCIe Riser Configurations

Please Choose one option below.

OCP NIC (Optional)

The system allows either LOM card or an OCP card or both to be installed in the system.
Supported OCP PCIe width is x8 on system board, OCP downgrades x16 to x8 when OCP R1KTR/3Y64D/W5HC8 is installed.

GPU (Optional)

Supports up to 3 x 300 W (DW) or 6 x 75 W (SW)
GPU is not supported on 12 x 3.5-inch, 8 x 3.5-inch, 32 x E3.S configs and system configs with rear module installed.

BOSS (Optional)

Rail Kit (Optional)

Bezel (Optional)

TPM (Optional)

iDRAC9 (Optional)

Default iDRAC 9 Express

Power Supply Units (PSU)

Supports up to 2 PSU
Mixing of PSUs is not supported.

ECS Warranty

Helpful Tip: Once desired configuration is selected click "Add to Cart".
From the cart page you can submit a submit a quote request for best pricing

Quick Specs
Form Factor:

2U rack server

Processor | Max: 128 Cores

1x Gen 4 AMD EPYC 9004 Series

Memory | Max: 3TB

12 ECC DDR5 RDIMM 4800Mhz

Storage | Max: 368.64TB

Front bays:
Up to 8x 3.5" SAS/SATA (HDD/SSD) Max: 160 TB
Up to 12x 3.5" SAS/SATA (HDD/SSD) Max: 240 TB
Up to 8x 2.5" SAS/SATA/NVMe (HDD/SSD) Max: 122.88 TB
Up to 16x 2.5" SAS/SATA/NVMe (HDD/SSD) Max: 245.76 TB
Up to 24x 2.5" SAS/SATA/NVMe (HDD/SSD) Max: 368.64 TB
Up to 8x EDSFF E3.S Gen5 NVMe (SSD) Max: 61.44 TB
Up to 16x EDSFF E3.S Gen5 NVMe (SSD) Max: 122.88 TB
Up to 32x EDSFF E3.S Gen5 NVMe (SSD) Max: 245.76 TB
Rear bays:
Up to 2 x 2.5" SAS/SATA/NVMe (HDD/SSD) Max: 30.72 TB
Up to 4 x 2.5" SAS/SATA/NVMe (HDD/SSD) Max: 61.44 TB
Supported in the 12LFF and the 24SFF Backplane

Boot Options

Boot Optimized Server Storage (BOSS-N1) Hot-Swap
USB

RAID Controller: (Adapter PERC)

S160 (SATA/NVMe SW RAID)
H355, H755, H755N, H965i, HBA355i, HBA355e, HBA465e

LOM

2 x 1GbE LOM card with BCM5720 LAN controller

Networking Options | Max Speed: 4x 25GbE Ports

OCP 3.0 x8 Mezz 3.0

Remote Management:

iDRAC9 with Lifecycle Controller

PCIe Slots Max: 8

4 x PCIe Gen5 slots
4 x PCIe Gen4 slots

GPU:

Up to 3 x 300 W DW
or 6 x 75 W SW


Ideal for:
  • Data Analytics
  • High-Performance Computing (HPC)
  • Virtual Desktop Interface (VDI)
  • Virtualization

The new Dell PowerEdge R7615 is a 2U, single-socket rack server. Designed to be the best investment per dollar for your data center, this server provides performance and flexible, low-latency storage options in an air or Direct Liquid Cooling (DLC) configuration.

The Dell PowerEdge R7615 Rack Server is a highly scalable Single-socket 2U rack server that delivers performance and outstanding TCO. It is ideal for the following workloads and applications


Stay ahead of the curve

Delivering breakthrough innovation for traditional and emerging workloads, including software-defined storage, data analytics, and virtualization using the latest performance and density with optional acceleration.


Invest wisely in a platform that grows with your business
  • Using AMD EPYC 4th generation processor to deliver up to 50% more core count per single socket platform in an innovative air-cooled chassis.
  • Enables DDR5 at 4800 MT/s memory and PCIe Gen5 with double the speed of previous Gen4 for faster access and transport of data optimizing application output.
  • Optional DLC is available to more efficiently cool high-performance processors.

Experience more virtual machine density to support the most demanding applications
  • Deliver more virtual machines per physical host using increased core count and higher memory footprint than previous generations.
  • Improve responsiveness or reduce app load time for power users with up to 6 x single-wide full-length GPUs or 3 x double-wide full-length GPUs.

Expect increased expandability by storing more data in one server, saving space in your data center
  • Deliver more memory density with DDR5 (up to 3 TB of RAM) providing greater memory capacity per socket.
  • Support lower latency higher performance NVMe SSD in a hardware RAID solution helps maximize compute performance.

Cyber Resilient Architecture for Zero Trust IT environment & operations Security is integrated into every phase of the PowerEdge lifecycle, including a protected supply chain and factory-to-site integrity assurance. Silicon-based root of trust anchors end-to-end boot resilience while Multi-Factor Authentication (MFA) and role-based access controls ensure trusted operations.


Dell PowerEdge R7615 Base Knowledge

2U rack server 12 DDR5 DIMM slots, supports RDIMM 3 TB max, speeds up to 4800 MT/s. With so many chassis to choose from. You can really mix and match this system to however you need it to be. For more details about configurations please view the “Cable Routing” section of the manual below.

Drive Options | Front & Rear
Drive Configuration Options:

There are a few chassis options.

  • Up to 8x 3.5" SAS/SATA (HDD/SSD) Max: 160 TB
  • Up to 12x 3.5" SAS/SATA (HDD/SSD) Max: 240 TB
  • Up to 8x 2.5" SAS/SATA/NVMe Universal Max: 122.88 TB
  • Up to 8x 2.5" NVMe
  • Up to 16x 2.5" (8 Universal + 8 Universal)
  • Up to 24x 2.5" SAS/SATA/NVMe Universal Max: 368.64 TB
  • Up to 24x 2.5" NVMe Passive
  • Up to 8x EDSFF E3.S Gen5 NVMe (SSD) Max: 61.44 TB
  • Up to 16x EDSFF E3.S Gen5 NVMe (SSD) Max: 122.88 TB
  • Up to 32x EDSFF E3.S Gen5 NVMe (SSD) Max: 245.76 TB

Read Drive Options Image of the read drive options in the Dell R7615 Rack Server.

The R7615 has two rear drive options that are only supported in the 12LFF and the 24SFF Backplane Chassis Configurations. There is a Stacked Side-by-Side 4xSFF drive cage and a Side-by-Side 2xSFF Drive cage. These will take over the PCIe slots that use up the same space. The Table below will show you all the configurations possible for this Dell PowerEdge R7615 Rack Server.

AMD Processor & Heatsink

The Dell PowerEdge R7615 supports One 4th Generation AMD EPYC 9004 Series processor with up to 128 cores per processor.

Heatsink & Fans

The PowerEdge R7615 requires various cooling components based on CPU TDP, storage modules, rear drives, GPU, and persistent memory to maintain optimum thermal performance. If a GPU is installed you will need to install the L-Type Heat Sink. Air cooling or Optional Direct Liquid Cooling (DLC) are the two options for cooling the system. Required for certain CPU SKUs and/or configuration. DLC cooling is not a self-contained solution, it requires rack-level product support (see DLC 3000 or DLC 7000 products).

The PowerEdgeR7615system system supports up to six high-performance silver grade (HPR SLVR) or high-performance gold (HPR Gold) cooling fans.

For all the details about the cooling specs of this server, please view the “Thermal restriction matrix” on the Dell R7615 Installation and Service Manual.

Image of the 4th Gen AMD Processor for Dells R7615 Rack Server

Memory Options

With only 1 Processor in the Dell PowerEdge R7615 Rack Server. It can only hold 12 DDR5 DIMM slots and supports RDIMM up to 3 TB max, speeds up to 4800 MT/s. The R7615 only supports registered ECC DDR5 DIMMs.

Unbuffered DIMMs (UDIMMs) are not supported.
DIMM type DIMM rank DIMM capacity Single processor Data Width DIMM Volts (V)
Minimum system capacity Maximum system capacity
DDR5 RDIMM Single rank 16 GB 16 GB 196 GB x8 1.1
DDR5 RDIMM Dual rank 32 GB 32 GB 384 GB x8 1.1
DDR5 RDIMM Dual rank 64 GB 64 GB 768 GB x4 1.1
DDR5 RDIMM Quad rank 128 GB 128 GB 1536 GB x4 1.1
DDR5 RDIMM Octa rank 256 GB 256 GB 3072 GB x4 1.1
Note: Do not mix x4 and x8 DIMMs with a memory channel.
Note: Unbuffered DIMMs (UDIMMs) are not supported.
Networking Adapters Options

The PowerEdge R7615 system supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports embedded on the LAN on Motherboard (LOM) and integrated on the Open Compute Project (OCP) cards.

Feature Specifications
(Optional) LOM card 1 Gb x 2
(Optional) OCP card (OCP 3.0) 1GbE x 4, 10 GbE x 2, 10 GbE x 4, 25 GbE x 2, 25 GbE x 4
Note: The system allows either LOM card or an OCP card or both to be installed in the system
Note: On the system board, the supported OCP PCIe width is x8; when x16 PCIe width is installed, it is downgraded to x8.
Storage Controllers Options

The Dell R7615 supports PERC 11 and PERC 12 cards for both RAID and Networking purposes. There are a few configurations where you can install both NVME and SAS/SATA drives in the same Chassis. This is done in two ways. Select the 24 Bay Universal Chassis that has Direct Connect NVMe ports for up to 8 drives. Or you can choose the 8 SFF NVMe Chassis and install an extra 8 SFF Universal backplane for a total of 16 drives. The 8 SFF NVMe Backplane is not a direct connect so you will need to install a fPERC.

There are a few more configurations worth looking into. You can find them in the cabling section of the manual below.


Supported storage controller card
Software RAID
  • S160
Internal controllers
  • PERC H965i
  • PERC H755
  • PERC H755N
  • PERC H355
Internal Boot
  • Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 2 x M.2 SSDs
External controllers
  • HBA355e
  • HBA465e
SAS Host Bus Adapters
  • HBA355i
Expansion Slots

Up to eight PCIe slots, 4 x PCIe Gen5 slots, and 4 x PCIe Gen4 slots.


PCIe Riser Configurations

Click to view more details about each configuration.

Config # RSR Configuration # of CPUs PERC type supported Rear Storage Possible
0 NO RSR 1 Front PERC No
1 R2a + R3a + R4p (HL) 1 Front PERC/ PERC Adapter No
2 R1u + R2a + R3b + R4q 1 Front PERC/ PERC Adapter No
3-1 R1t + R2t + R3b + R4p (HL) 1 Front PERC/ PERC Adapter No
3-2 R1t + R2t + R3b + R4p (FL) 1 Front PERC No
4-2 R1t + R2t + R3a + R4p (HL) 1 Front PERC No
4-2 R1t + R2t + R3a + R4p (FL) 1 Front PERC No
5-1 R1t + R2t + R3a + R4s (HL) 1 Front PERC No
5-2 R1t + R2t + R3a + R4s (FL) 1 Front PERC/ PERC Adapter No
6 R2t + R4q 1 Front PERC/ PERC Adapter Yes
7 R1u + R2t + R4q 1 Front PERC/ PERC Adapter Yes
8 R2a + R4a (HL) 1 Front PERC/ PERC Adapter No
9 R2a + R3a + R4p (HL) 1 PERC Adapter Yes
10 R1u+R3b+4q (HL) 1 Front PERC/ PERC Adapter Yes
GPU

The Dell R7615 Rack Server Supports up to 3 x 300 W DW or 6 x 75 W SW. Below is a parts reference to understand what goes into installing a GPU and the parts needed. If you want more detail into this please read the manuals below.

Components GPU FL kit
Details Quantity
Risers Riser configuration (RC) 3-2, 5-2*, or, 10-2* RC 3-2: R1P^ (FL) + R2A (HL) + R3B (HL) + R4P^ (FL)
RC 5-2: R1R (FL) + R2A (HL) + R3A (FL) + R4P^ (FL)
RC 10-2: R1P^ (FL) + R2A (HL) + R4R (FL)
Shroud GPU shroud 1
Fans HPR GOLD fan 6
Heat sinks L-type heat sink for processor 1 and processor 2 RC 3-2, 5-2: 2
RC 10-2: 1
Cables Power cable 2 x 4 (8-position) or 2 x 6 + 1 x 4 (12-position + 4-sideband)
FL - Full Length, HL - Half Length, HPR - High Performance, RC - Riser configuration
GPU is not supported on 12 x 3.5-inch configs and system configs with rear module installed.
“High-Performance GOLD Fan” to be supported on all GPU configs
R1P and R4P supports Double Width (DW) GPU.
The configuration 5-2 supports DW GPU only on slots 7 and configuration 10 supports DW GPU only on slot 2.
All GPU cards require L-type heat sink and GPU shroud, irrespective of the length. However, the cooling fan and foam are dependent on different configurations
Power, Dimensions, and Weight
Power

Dual hot-swap redundant Power Supplies. Do not mix power supplies.

  • 2400W Platinum 100—240 VAC or 240 HVDC
  • 1800W Titanium 200—240 VAC or 240 HVDC
  • 1400W Platinum 100—240 VAC or 240 HVDC
  • 1100W Titanium 100—240 VAC or 240 HVDC
  • 1100W LVDC -48 — -60 VDC
  • 800W Platinum 100—240 VAC or 240 HVDC
  • 700W Titanium 200—240 VAC or 240 HVDC

Dimensions & Weight:
Width: 482 mm (18.97")
Height: 86.8 mm (3.41")
Length: 772.13 mm (30.39") with bezel
------------- 758.29 mm (29.85") without bezel

Weight
A server with fully populated drives 34.5 kg (76.05 pounds)
A server without drives and PSU installed 25.7 kg (56.65 pounds

Base Standard Capabilities

FeatureTechnical Specifications
ProcessorOne 4th Generation AMD EPYC 9004 Series processor with up to 128 cores per processor
Memory• 12 DDR5 DIMM slots, supports RDIMM 3 TB max, speeds up to 4800 MT/s
• Supports registered ECC DDR5 DIMMs only
Storage controllers• Internal Controllers: PERC H965i, PERC H755, PERC H755N, PERC H355, HBA355i
• Internal Boot: Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSDs or USB
• External HBA (non-RAID): HBA355e
• Software RAID: S160
Drive BaysFront bays:
• Up to 8 x 3.5-inch SAS/SATA (HDD/SSD) max 160 TB
• Up to 12 x 3.5-inch SAS/SATA (HDD/SSD) max 240 TB
• Up to 8 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 122.88 TB
• Up to 16 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 245.76 TB
• Up to 24 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 368.64 TB
• Up to 8 x EDSFF E3.S Gen5 NVMe (SSD) max 61.44 TB
• Up to 16 x EDSFF E3.S Gen5 NVMe (SSD) max 122.88 TB
• Up to 32 x EDSFF E3.S Gen5 NVMe (SSD) max 245.76 TB
Rear bays:
• Up to 2 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 30.72 TB
• Up to 4 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 61.44 TB
Power Supplies• 2400 W Platinum 100—240 VAC or 240 HVDC, hot swap redundant
• 1800 W Titanium 200—240 VAC or 240 HVDC, hot swap redundant
• 1400 W Platinum 100—240 VAC or 240 HVDC, hot swap redundant
• 1100 W Titanium 100—240 VAC or 240 HVDC, hot swap redundant
• 1100 W LVDC -48 — -60 VDC, hot swap redundant
• 800 W Platinum 100—240 VAC or 240 HVDC, hot swap redundant
• 700 W Titanium 200—240 VAC or 240 HVDC, hot swap redundant
Cooling Options• Air cooling
• Optional Direct Liquid Cooling (DLC)
Note: DLC is a rack solution and requires rack manifolds and a cooling distribution unit (CDU) to operate.
Fans• High performance Silver (HPR) fans/ High performance Gold (VHP) fans
• Up to 6 hot plug fans
Dimensions• Height – 86.8 mm (3.41 inches)
• Width – 482 mm (18.97 inches)
• Depth – 772.13 mm (30.39 inches) with bezel
758.29 mm (29.85 inches) without bezel
Form Factor2U rack server
Embedded Management• iDRAC9
• iDRAC Direct
• iDRAC RESTful API with Redfish
• iDRAC Service Module
• Quick Sync 2 wireless module
BezelOptional LCD bezel or security bezel
OpenManage Software• CloudIQ for PowerEdge plug in
• OpenManage Enterprise
• OpenManage Enterprise Integration for VMware vCenter
• OpenManage Integration for Microsoft System Center
• OpenManage Integration with Windows Admin Center
• OpenManage Power Manager plugin
• OpenManage Service plugin
• OpenManage Update Manager plugin
MobilityOpenManage Mobile
OpenManage Integrations• BMC Truesight
• Microsoft System Center
• OpenManage Integration with ServiceNow
• Red Hat Ansible Modules
• Terraform Providers
• VMware vCenter and vRealize Operations Manager
Security• AMD Secure Memory Encryption (SME)
• AMD Secure Encrypted Virtualization (SEV)
• Cryptographically signed firmware
• Data at Rest Encryption (SEDs with local or external key mgmt)
• Secure Boot
• Secure Erase
• Secured Component Verification (Hardware integrity check)
• Silicon Root of Trust
• System Lockdown (requires iDRAC9 Enterprise or Datacenter)
• TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ
Embedded NIC2 x 1 GbE LOM card (optional)
Network options1 x OCP card 3.0 (optional)
Note: The system allows either LOM card or an OCP card or both to be installed in the system.
GPU OptionsUp to 3 x 300 W DW or 6 x 75 W SW
PortsFront Ports
• 1 x iDRAC Direct (Micro-AB USB) port
• 1 x USB 2.0
• 1 x VGA
Rear Ports
• 1 x Dedicated iDRAC Ethernet port
• 1 x USB 2.0
• 1 x USB 3.0
• 1 x VGA
• 1 x Serial (optional)
• 1 x VGA (optional for Direct Liquid Cooling configuration)
Internal Ports • 1 x USB 3.0 (optional)
PCIeUp to eight PCIe slots:
• Slot 1: 1 x8 Gen5 Full height, Half length
• Slot 2: 1 x8/1 x16 Gen5 Full height, Half length or 1 x16 Gen5 Full height, Full length
• Slot 3: 1 x16 Gen5 or 1 x8/1 x16 Gen4 Low profile, Half length
• Slot 4: 1 x8 Gen4 Full height, half length
• Slot 5: 1 x8/1 x16 Gen4 Full height, Half length or 1 x16 Gen4 Full height, Full length
• Slot 6: 1 x8/1 x16 Gen4 Low Profile, Half length
• Slot 7: 1 x8/1 x16 Gen5 or 1 x16 Gen4 Full height, Half length or 1 x16 Gen5 Full height, Full length
• Slot 8: 1 x8/1 x16 Gen5 Full height, Half length
Operating System and Hypervisors• Canonical Ubuntu Server LTS
• Microsoft Windows Server with Hyper-V
• Red Hat Enterprise Linux
• SUSE Linux Enterprise Server
• VMware ESXi

Spec Sheet 4

Rack Server R760 R660 R7625 R6625 R7615 R6615
Key attributes Provides performance and versatility for demanding applications Provides performance and versatility for demanding applications Breakthrough performance Breakthrough performance Powerful performance and scalability Peak performance and excellent TCO
Target workloads Mixed Workload Standardization Database and Analytics Virtual Desktop Infrastructure High Density Virtualization, Dense Database Analytics, Mixed Workload Standardization High Performance Computing (HPC), Virtual Desktop Infrastructure (VDI), Virtualization High Performance Computing (HPC), Virtual Desktop Infrastructure (VDI), Virtualization Software-Defined Storage (SDS), Virtualization, Data Analytics Virtualization, Hyper-Converged Infrastructure (HCI), Network Functions Virtualization (NFV)
Type of processor 2 x 4th Generation Intel® Xeon® Scalable processors; up to 56 cores per processor 2 x AMD EPYC™ 4th Generation 9004 Series Processor, up to 96 cores per processor 1 x AMD EPYC™ 4th Generation 9004 series processor; up to 96 cores
Memory (DDR5 DIMM slots & max) 32 (8 TB) 24 (1.5 TB*) 12 (768 GB*)
Disk drives up to: 12 x 3.5”
8 x 2.5”
16 x 2.5”
24 x 2.5”
2 x 2.5” or 4 x 2.5” (rear)
8 x 2.5”
10 x 2.5”
2 x 2.5” (rear)
8 x 3.5”
12 x 3.5”
8 x 2.5”
16 x 2.5”
24 x 2.5”
2 x 2.5” or 4 x 2.5”(rear)
4 x 3.5”
8 x 2.5”
10 x 2.5”
2 x 2.5” (rear)
8 x 3.5”
12 x 3.5”
8 x 2.5”
16 x 2.5”
24 x 2.5”
2 x 2.5” or 4 x 2.5”(rear)
4 x 3.5”
8 x 2.5”
10 x 2.5”
2 x 2.5” (rear)
NVMe drives up to: 24 10 24 10 24 10
Gen5 PCIe slots up to: 4 2 4 2 4 2
Gen4 PCIe slots up to: 8 3 8 3 4 3
Accelerator support up to: 2 x 350 W DW or 6 x 75 W SW 2** x 75 W SW 2 x 300 W DW or 6 x 75 W SW 3 x 75 W SW 3 x 300 W DW or 6 x 75 W SW 3 x 75 W SW
Rack height (U) 2 1 2 1 2 1
Integrated security TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ, Cryptographically Signed Firmware, Chassis Intrusion Alert, Secure Boot being standard security, Silicon Root of Trust, System Lockdown (requires iDRAC9 Enterprise or Datacenter), Data at Rest Encryption (SEDs with local or external key mgmt) Secured Component Verification (Hardware integrity check) and System Erase on all racks. TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ, Cryptographically Signed Firmware, Secure Boot, Secure Erase, Silicon Root of Trust, System Lockdown (requires iDRAC9 Enterprise or Datacenter), AMD Secure Memory Encryption (SME) and AMD Secure Encrypted Virtualization (SEV)
* Future releases will include additional system capacity for DDR5 memory in R7625, R6625, R7615 and R6615.
** Future releases will include additional GPU slots in R660.