Current Configuration
(List below serves as quick links to each section)
Server Chassis
Processors
Bezel
Memory
Extra Drive Options
HDD 3.5" Drives
HDD 2.5" Drives
SSD 2.5" Drives
SSD U.2 NVMe Drives Gen 4
SSD 1.8" EDSFF E3.S NVMe Drives
Network Daughter Card (NDC) LOM
PCIe Riser Options
RAID Controllers
Internal Dual SD Module (IDSDM)
Rail Kits
Trusted Platform Module (TPM)
iDRAC Remote Options
Power Supplies
ECS Warranty
The request has been sent.
Thank you.
Price as Configured:
$0
Price as Configured:
$0
2U rack server
Processor | Max: 22 Cores2 x Intel Xeon E5-2600v3 or v4
Memory | Max: 768GB24 ECC DDR4 RDIMM/LRDIMM 2133Mhz
Storage | Max: 99.6TB LFF | 31.9TB 1.8" SFF | 43.2TB SFF12x LFF Chassis Drive Options
- 12x 3.5” + 2x 2.5” (Rear)
- 12x 3.5” + 4x 3.5" (Internal) + 2x 2.5” (Rear)
- 18x 1.8" SFF + 8x 3.5" + 2x 2.5" (Rear)
- 20x 2.5" + 4x PCIe NVMe + 2x 2.5" (Rear)
- 24x 2.5" + 2x 2.5" (Rear)
The R730xd supports up to 4x Express Flash drives in the 24 2.5" Chassis.
RAID Controller:H330, H730, H730P, H830, 12Gbps SAS HBA
S130 (software RAID; R730 only)
4 x 1GbE, 2x10+2GbE, 4 x 10GbE NDC
(Many Options to choose from)
iDRAC8 Express (default) with Lifecycle Controller
PCIe Slots:Up to 6 x PCIe 3.0 + dedicated PERC slot
-Three x8 full-length, full-height
-Three x8 half-length, half-height
Not Supported
The R730 and R730xd cannot connect to the PowerEdge C410x
- Dell PowerEdge R710
- Dell PowerEdge R720
- Dell PowerEdge R720XD
- Dell PowerEdge R730
- Dell PowerEdge R730XD
- Dell PowerEdge R740
- Dell PowerEdge R740XD
- Dell PowerEdge R740XD2
- Dell PowerEdge R7415
- Dell PowerEdge R7425
- Dell PowerEdge R750
- Dell PowerEdge R750XA
- Dell PowerEdge R750XS
- Dell PowerEdge R7515
- Dell PowerEdge R7525
- Dell PowerEdge R760
- Dell PowerEdge R760XA
- Dell PowerEdge R760XS
- Dell PowerEdge R760XD2
- Dell PowerEdge R7615
- Dell PowerEdge R7625
- Database
- High-Performance Computing (HPC)
- Retail Servers
- Virtual Desktop Interface (VDI)
The server has up to 6 PCIe 3.0 expansion slots, supports up to 4 Express Flash NVMe PCIe SSDs, and offers up to 26 x 2.5” SAS, SATA, nearline SAS, SSD, PCIe SSD drives, making it an excellent resource-rich virtualization environment. It has a 24-drive capacity with dual-PERC capability that drives storage performance, and it features Dell caching technologies that boost application performance.
Drive peak performance
One of the unique features of the R730xd is its incredible range of configurability, which allows for the mixing of high-speed 1.8” SSDs and low-cost, high-capacity 3.5” hard drives in a single hybrid chassis, enabling accelerated data access through in-server storage tiering. This hybrid storage configuration can support tiering and capacity for up to 28 drives in a 2S/2U system, including up to 18 x 1.8" SATA SSDs.
Discover greater versatility
The R730xd is an excellent database server that can deliver more than one million IOPS performance, and it is ideal for Microsoft SharePoint and Exchange server for unified communications and collaboration (UC&C). The server is suitable for XaaS providers, Hadoop/big data users, and colocation hosting.
The PowerEdge R730xd is also designed to enhance database performance by using flash drives to cache "hot" data while simultaneously having up to 48TB of server-based storage with NL-SAS/SATA HDDs. It can increase concurrent usage and system response for OLTP applications by combining NVMe drives and Dell caching solutions. Additionally, the server is compatible with software-defined storage (SDS) solutions, making it an ideal choice for storage virtualization.
The R730xd supports up to 24 x 2.5”, 12 x 3.5”, or 8 x 3.5” plus 18 x 1.8” front-accessible, hot-plug drives that are secured by a removable front bezel. Other front-panel features include an LED control panel, USB management port/iDRAC Direct and video connector.
The R730xd includes 2 optional 2.5” hot-plug drives in the back of the system.
The R730xd supports up to 24 DIMMs, 2 processors hot-plug redundant fans, and many other components and features.
- (8 Drive System) 8x 3.5"
- (10 Drive System) 8x 3.5" + 2x Rear 2.5"
- (12 Drive System) 12x 3.5"
- (14 Drive System) 12x 3.5" + 2x Rear 2.5"
- (18 Drive System) 12x 3.5" + 4x Mid Tray 3.5" + 2x Rear 2.5"
- (26 Drive System) 18x 1.8" Top + 8x 3.5" Bottom + 2x Rear 2.5"
- (26 Drive System) 24x 2.5" + 2x Rear 2.5"
- (26 Drive System) 20x 2.5" + 4x PCIe SSD NVMe + 2 Rear 2.5"
Mid TrayThe Mid Tray is only supported on the 12 Bay Chassis.
1.8" SFF E3.S DrivesThe 3.5" Chassis has the option to install the 18-bay 1.8" SFF backplane on the top section of the server.
NVMe PCIe SSD DrivesOnly on the 24 Bay Chassis will the R730xd support up to (4) NVMe drives.
Rear Drive CageEvery Chassis option supports the rear drive cage. The rear-drive cages can hold HDD or SSD drives.
Features such as Express Flash PCIe SSDs and DAS Cache provide vastly accelerated performance over previous technologies. Dell Express Flash drives use PCIe lanes to connect directly to the processor and chipset and are easily accessible through a hot-plug drive bay (R730xd only; R730 does not support Express Flash drives).
This feature is only supported on the 24 Bay 2.5" SSD Chassis and is only allowed in drive slots 20 - 24. To get this to work, you must install the PCIe Bridge into one of the 6 PCIe slots in the back. This PCIe Bridge will port extra PCIe lanes to the front drive bays.
| DIMM capacity | DIMM speed | DIMM type | Ranks per DIMM | Data width | SDDC support | Voltage |
|---|---|---|---|---|---|---|
| 4 | 2133 | RDIMM | 1 | x8 | Advanced ECC | 1.2 |
| 8 | 2133 | RDIMM | 2 | x8 | Advanced ECC | 1.2 |
| 16 | 2133 | RDIMM | 3 | x4 | All modes | 1.2 |
| 32 | 2133 | LRDIMM | 4 | x4 | All modes | 1.2 |
The Dell PowerEdge R730xd offers balanced, scalable I/O capabilities, including integrated PCIe 3.0-capable expansion slots. Dell Select Network Adapters, Dell’s network daughter cards, let you choose the right network fabric without using up a valuable PCI slot.
The R730xd supports NDC options including a selection of 1GbE and 10GbE port cards, such as 1000BASE-T, 10GBASE-T and 10Gb SFP+.

The base RAID controller in the R730 and R730xd is the miniPERC, which provides a base RAID hardware controller without consuming a PCIe slot by using a small form factor and high-density connector to the base planar. The secondary RAID controller is limited to the H730P low-profile PCIe controller. In two-controller systems, both controllers must be the H730P.

| Controller | Features | RAID modes supported | Form factor | Solution |
|---|---|---|---|---|
| PERC H830 |
|
0, 1, 10, 5, 50, 6, 60 | Adapter | Performance hungry external storage environments |
| PERC H730P |
|
0, 1, 10, 5, 50, 6, 60 | Mini and Adapter | Premium performance for significant performance gains |
| PERC H730 |
|
0, 1, 10, 5, 50, 6, 60 | Mini and Adapter | Value/performance RAID and non RAID for high density servers and workstations |
| PERC H330 |
|
0, 1, 10, 5, 50 | Mini and Adapter | Low cost, entry RAID and non RAID for high density servers and workstations |
| PERC S130 |
|
0, 1, 5, 10 | System board embedded SATA | Software |
The R730xd provides greatly expanded PCIe slot capability over their predecessor servers. This is made possible by the 40 PCIe lanes available from each processor in the system. Two processors are required in the system to enable all PCIe slots. The Dell PowerEdge R730xd has been designed to be PCIe 3.0 compliant in order to take full advantage of the processor's capabilities.
NOTE: In a single-processor configuration, slots 1–4 are not usable.
- Three x8 full-length, full-height
- Three x8 half-length, half-height
| Riser | Slot number | Form factor | Controlling CPU | Slot electrical bandwidth and physical connector | Power |
|---|---|---|---|---|---|
| Right riser 1 | 1 | Low profile | CPU2 | PCIe 3.0 x8 (x16 connector) | 25W |
| Right riser 1 | 2 | Low profile | CPU2 | PCIe 3.0 x8 (x16 connector) | 25W |
| Right riser 1 | 3 | Low profile | CPU2 | PCIe 3.0 x8 (x16 connector) | 25W |
| Center riser 2 | 4 | Full height | CPU2 | PCIe 3.0 x16 (x16 connector) | 75W |
| Center riser 2 | 5 | Full height | CPU1 | PCIe 3.0 x8 (x16 connector) | 75W |
| Left riser 3 | 6 | Full height | CPU1 | PCIe 3.0 x8 (x16 connector) | 75W |
| Left riser 3 | 7 | Full height | CPU1 | PCIe 3.0 x8 (x16 connector) | 75W |
| Left riser 3 alternative | 6 | Full height | CPU1 | PCIe 3.0 x16 (x16 connector) * Rear Drives are installed under this card. | 75W |
Right Riser 13x Low Profile
PCIe 3.0 x8 (x16 connector)
Power: 25W
Center Riser 22x Full height
Slot 4: PCIe 3.0 x16 (x16 connector)
Slot 5: PCIe 3.0 x8 (x16 connector)
Power: 75W
Left Riser 32x Full Height
PCIe 3.0 x8 (x16 connector)
Power: 75W
Left Riser 3 (Alternative)1x Full Height
PCIe 3.0 x16 (x16 connector) *For DW GPUs
Power: 75W
| Form factor | Output | Class |
|---|---|---|
| Redundant 86mm | 495W AC | Platinum |
| 750W AC | Titanium | |
| 750W AC | Platinum | |
| 1100W AC | Platinum | |
| 1100W DC | N/A |
- Height: 87.3mm (3.43")
- Depth: 716.0mm (28.01")
- Width: 482.4mm (18.97")
- Weight: 29.5kg (64.9lb)
Current Configuration
(List below serves as quick links to each section)
Server Chassis
Processors
Bezel
Memory
Extra Drive Options
HDD 3.5" Drives
HDD 2.5" Drives
SSD 2.5" Drives
SSD U.2 NVMe Drives Gen 4
SSD 1.8" EDSFF E3.S NVMe Drives
Network Daughter Card (NDC) LOM
PCIe Riser Options
RAID Controllers
Internal Dual SD Module (IDSDM)
Rail Kits
Trusted Platform Module (TPM)
iDRAC Remote Options
Power Supplies
ECS Warranty
The request has been sent.
Thank you.
Price as Configured:
$0
Base Standard Capabilities
| Feature | PowerEdge R730xd Technical Specification | |
|---|---|---|
| Form factor | 2U rack server | |
| Processor | Intel® Xeon® processor E5-2600 v3 product family | |
| Processor sockets | 2 | |
| Dimensions and weight | H: 8.73 cm (3.44 in.) x W: 44.40 cm (17.49 in.) x D: 68.40 cm (26.92 in.) | |
| Cache | 2.5MB per core; core options: 4, 6, 8, 10, 12, 14, 16, 18 | |
| Chipset | Intel C610 series chipset | |
| Memory | Up to 768GB (24 DIMM slots): 4GB/8GB/16GB/32GB DDR4 up to 2133MT/s | |
| I/O slots | Up to 6 x PCIe 3.0 slots plus dedicated RAID card slot | |
| RAID controllers | Internal controllers: PERC H330, PERC H730, PERC H730P External HBAs (RAID): PERC H830 External HBAs (non-RAID): 12Gbps SAS HBA | |
| Drive bays | Internal hard drive bay and hot-plug backplane:
| |
| Maximum internal storage | SAS, SATA, nearline SAS, SSD, PCIe SSD:
| |
| Embedded NIC | 4 x 1GbE, 2x10+2GbE, 4 x 10GbE NDC | |
| Power supplies | Titanium efficiency 750W AC power supply; 1100W DC power supply; Platinum efficiency 495W, 750W, 1100W AC power supply; | |
| Availability | ECC memory, hot-plug hard drives, hot-plug redundant cooling, hot-plug redundant power, internal dual SD module, single device data correction (SDDC), spare rank, tool-less chassis, support for high availability clustering and virtualization, proactive systems management alerts, iDRAC8 with Lifecycle Controller | |
| Remote management | iDRAC8 with Lifecycle Controller iDRAC8 Express (default) iDRAC8 Enterprise (upgrade) 8GB vFlash media (upgrade) 16GB vFlash media (upgrade) | |
| Systems management |
| |
| Operating system | Microsoft Windows Server® 2008/2012 SP2, x86/x64 (x64 includes Hyper-V®) Microsoft Windows Server 2008/2012 R2, x64 (includes Hyper-V) Microsoft Windows HPC Server 2008 Novell® SUSE® Linux Enterprise Server Red Hat® Enterprise Linux | |
| Rack support | ReadyRails™ II sliding rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded hole racks, with support for optional tool-less cable management arm. | |
Spec Sheet 4
| Feature | PowerEdge R720/R720xd | PowerEdge R730/R730xd |
|---|---|---|
| Chassis | 2U rack | 2U rack |
| Processors | Intel Xeon processor E5-2600 v2 product family | Intel Xeon processor E5-2600 v3 product family |
| Internal interconnect | Intel QuickPath Interconnect (QPI) | Intel QPI |
| Memory | 24 x DDR3 RDIMM, UDIMM, and LRDIMM Up to 768GB | 24 x DDR4 RDIMM and LRDIMM Up to 768GB |
| Disk drives | R720:
Up to 16 x 2.5“ or 8 x 3.5” 6Gb SAS, 3Gb SATA R720xd: Up to 26 x 2.5” SAS SSD, SATA SSD, SAS, NLSAS, SATA, SAS 512n or 12 x 3.5” SAS, NL-SAS, SATA + 2 x 2.5” drives |
R730:
Up to 16 x 2.5” HDD: SAS, SATA, NL-SAS; SSD: 12Gb SAS, 6Gb SATA Up to 8 x 3.5” HDD: SATA, NL-SAS; SSD: 12Gb SAS, 6Gb SATA R730xd: Up to 24 x 2.5” + 2 x 2.5” HDD: SAS, SATA, NL-SAS; SSD: 12Gb SAS, 6Gb SATA, up to 4 NVMe Express Flash PCIe Up to 16 x 3.5” + 2 x 2.5” HDD: SAS, SATA, NL-SAS; SSD: 12Gb SAS, 6Gb SATA |
| RAID controller | PERC S110 (software RAID), H310, H710,
H710P, H810 (external); support for 2 internal RAID controllers |
PERC S130 (software RAID), H330,
H730, H730P, H830 (external); support for 2 internal RAID controllers |
| PCI slots | Max 7 + 1 x PCIe 3.0/6 + 1 x PCIe 3.0 | Max 7 + 1 x PCIe 3.0/6 + 1 x PCIe 3.0 option to eliminate Riser 1 |
| Embedded NICs | Select Network Adapter NDC 4 x 1GbE, 2 x 10GbE |
Select Network Adapter NDC 4 x 1GbE, 2 x 10GbE, 4 x 10GbE |
| USB | USB 2.0 | USB 3.0 (back and internal ports only) |
| Power supplies | Hot-plug, redundant power supply units:
>95W AC, 750W AC, 750W AC/DC mixed mode, 1100W AC, 1100W DC |
Hot-plug, redundant power supply units:
495W AC, 750W AC, 750W AC/DC mixed mode2, 1100W AC, 1100W DC |
| Power efficiency 80 PLUS® certification | Titanium and Platinum | Titanium and Platinum |
| Dell OpenManage Systems Management | OpenManage Essentials
Dell Management Console IT Assistant OMSA Agent OpenManage Power Center (requires iDRAC7 Enterprise with Lifecycle Controller) OpenManage Integrations and Connections iDRAC7 Express with Lifecycle Controller (standard option) |
OpenManage Essentials
Dell Management Console OMSA Agent OpenManage Power Center (requires iDRAC8 Enterprise with Lifecycle Controller) OpenManage Integrations and Connections iDRAC8 Express with Lifecycle Controller (standard option) |
| Internal GPU | 2 x 300W (double-wide) or
4 x 150W (single-wide) Not supported on R720xd |
2 x 300W (double-wide) or
4 x 150W (single-wide) Not supported on R730xd |
| Availability | Hot-plug drives
Hot-plug redundant cooling Hot-plug redundant PSUs IDSDM support |
Hot-plug drives