Current Configuration
(List below serves as quick links to each section)
HPE Chassis
HPE Processors
Cable Kit
Memory E5-2600v3
Memory E5-2600v4
Drive Options
HPE LFF Drives SAS (3.5in)
HPE LFF Drives SATA (3.5in)
HPE SFF Drives SAS (2.5in)
HPE SFF Drives SATA (2.5in)
HPE M.2 Drives and Micro SD
PCI Riser Options
Network Adapters
FlexibleLOM Adapter
InfiniBand Adapter
Controller State
Storage Controller
Host Bus Adapters (HBAs)
Workload Accelerators
iLO Server Management
Rail Kit
Power Supply Unit (PSU)
Select Warranty
The request has been sent.
Thank you.
Price as Configured:
$0
Price as Configured:
$0
-PLEASE CONTACT FOR CUSTOM CONFIGURATIONS. DISK SHELVES, COMPLETE CONFIGURATIONS & TURN KEY SYSTEMS AVAILABLE.
-SPARE PARTS AVAILABLE FOR EACH MODEL. PLEASE ASK FOR PRICING ON SPARE DISK, CONTROLLERS, POWER SUPPLIES, NICs, HBAs, SFPs, Cables, etc.
- (3) 4U Chassis Options
- D6000 DAS Support
- XL450 Node server (786593-B21)
- (2) Intel Xeon E5-2600 v3 and v4
- (16) 2400MT/s DDR4 DIMMs Per Node
- (4) PCIe Slots per 2Socket Node
- HPE Ethernet 1Gb 2-port 361i Adapter standard
- HPE iLO 4
- Big Data Analytics
- Cloud Servers
- Data Analytics
- Database
- High-Performance Computing (HPC)
- Hyper-Converged infrastructure (HCI)
- Virtualization
With the HPE Apollo 4500 Systems, HPE challenges the notion that one-size-fits all for Big Data infrastructure by creating purpose-built systems that specifically address storage and analytics workloads.
For object storage, the ultra-dense Apollo 4510 includes 1 server and up to 68 Large Form Factor (LFF) drives in a 4U chassis for a maximum of 680 TB per system.. For Hadoop® and other Big Data solutions, the Apollo 4530 uniquely offers 3 servers per chassis, ideal for housing 3 copies of data in a single system.
CTO Configuration Support
Need help with the configuration? Contact us today!

- (2) Intel Xeon E5-2600 v3 and v4
- (16) 2400MT/s DDR4 DIMMs Per Node
- (2) SFF SAS/SATA HDD/SSD
- (4) PCIe Slots per 2 Socket Node
- Up to (2) M.2 Drives
- HPE Dynamic Smart Array B140i SATA RAID
- HPE Ethernet 1Gb 2-port 361i Adapter standard
SFF SAS drives are selected, H244br or P244br is required.
-
HPE Apollo XL450 Service Guide
-
HPE Apollo XL450 User Guide
Apollo 4510 Chassis (799581-B21)- (1) XL450 Node | 786593-B21
- (68) LFF SAS/SATA Drives
- (4) PCIe Slots
- (8) LFF Rear Drive | 799377-B21
Chassis Manuals
-
Apollo 4510 Service Guide
-
Apollo 4510 Installation Guide
Apollo 4520 Chassis (799581-B22)- (2) XL450 Node | 786594-B22
- 2 SAS EXP for Failover
- (46) LFF SAS Drives
- (8) PCIe Slots
- SAS ONLY
Chassis Manuals
-
Apollo 4520 Service Guide
-
Apollo 4520 Installation Guide
Apollo 4530 Chassis (799581-B23)- (3) XL450 Node | 786595-B23
- (45) LFF SAS/SATA Drives
- (12) PCIe Slots
Chassis Manuals
-
Apollo 4530 Service Guide
-
Apollo 4530 Installation Guide
The HPE Smart Storage Battery supports up to two Smart Array Controllers per node. This dual controller configuration is only supported in the 4510 and 4520 Node.
Below is a table outlining the Controller QTY per Chassis. If you need 4 PCIe slots, 2 Processors are required.

- HPE Smart Array P440/4G Controller
- HPE Smart Array P840/4G Controller
- HPE H240 Smart HBA
For hardware RAID/HBA with LFF drives, one of the Controllers is required.
- HPE H241 Smart HBA
- HPE Smart Array P441/4G Controller
- HPE Smart Array P841/4G Controller
SA/HBA that end in 1 refer to external controllers for storage outside of the system. 0 refers to internal storage
| 1xH240 | 2xH240 | 1xP440 | 2xP440 | 1xP840 | |
|---|---|---|---|---|---|
| Apollo 4510 | x | x | x | x | x |
| Apollo 4520 | x | x | |||
| Apollo 4530 | x | x |
Apollo 4510 (4) PCIe Slots
Apollo 4520 (8) PCIe Slots
Apollo 4530 (12) PCIe Slots
The total PCIe slots available depend on the number of processors selected. One processor provides support for 2 PCIe slots (slots 1 and 2) and Two processors provide support for 4 PCIe slots per XL450 Node Server. Each riser has 1 FlexibleLOM slot and 4 PCIe slots.
The Apollo 4520 System offers an extra PCIe Riser options. The HPE Apollo 4500 x16 I/O Module Kit (855128-B21). Which contains one x16 bus width slot and three x8 PCIe slots.
| Expansion Slots # | Technology | Bus Width | Connector Width | Form Factor | Notes |
|---|---|---|---|---|---|
| 0 | PCIe 3.0 | x8 | x16 | Low Profile | CPU0; FlexibleLOM |
| 1 | PCIe 3.0 | x8 | x16 | Low Profile | CPU0; SA/HBA |
| 2 | PCIe 3.0 | x8 | x16 | Low Profile | |
| 3 | PCIe 3.0 | x8 | x16 | Low Profile | |
| 4 | PCIe 3.0 | x8 | x16 | Low Profile |
The HPE Apollo 4500 Gen9 systems are designed to support up to four hot-plug power supply units (PSUs), ensuring high availability and redundancy. These servers typically require a minimum of two power supplies for standard operation to provide redundancy and meet power requirements for workloads.

Current Configuration
(List below serves as quick links to each section)
HPE Chassis
HPE Processors
Cable Kit
Memory E5-2600v3
Memory E5-2600v4
Drive Options
HPE LFF Drives SAS (3.5in)
HPE LFF Drives SATA (3.5in)
HPE SFF Drives SAS (2.5in)
HPE SFF Drives SATA (2.5in)
HPE M.2 Drives and Micro SD
PCI Riser Options
Network Adapters
FlexibleLOM Adapter
InfiniBand Adapter
Controller State
Storage Controller
Host Bus Adapters (HBAs)
Workload Accelerators
iLO Server Management
Rail Kit
Power Supply Unit (PSU)
Select Warranty
The request has been sent.
Thank you.
Price as Configured:
$0
Base Standard Capabilities
Product features
Feature | Description | ||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Processor (One of the following depending on model) | E5-2600 v4 Series Twenty-Two Core Processors Intel Xeon E5 2699 v4 (2.2 GHz/22 core/55MB/145 W) Processor Twenty Core Processors Intel Xeon E5 2698 v4 (2.2 GHz/20 core/50MB/135 W) Processor Eighteen Core Processors
Sixteen Core Processors
Fourteen Core Processors
Twelve Core Processors Intel Xeon E5 2650 v4 (2.2 GHz/12-core/30MB/105 W) Processor Ten Core Processors
Eight Core Processors Intel Xeon E5 2620 v4 (2.1 GHz/8-core/20MB/85 W) Processor Six Core Processors Intel Xeon E5 2603 v4 (1.7 GHz/6-core/15MB/85 W) Processor E5-2600 v3 Series Sixteen Core Processors Intel Xeon E5-2698 v3 (2.3 GHz/16 core/40MB/135 W) Processor Fourteen Core Processors
Twelve Core Processors
Ten Core Processors
Eight Core Processors
Six Core Processors
| ||||||||||||||||||||||||||||||||||||
Chipset |
| ||||||||||||||||||||||||||||||||||||
Cache memory | E5-2600v4 Processors
E5-2600v3 Processors
| ||||||||||||||||||||||||||||||||||||
Legacy mode | HPE Legacy mode (FIO only - P/N 758959-B22) NOTE: UEFI is the default mode for CTO SKUs. Can change default to legacy VIA CTO. | ||||||||||||||||||||||||||||||||||||
On system management chipset | HPE Integrated Lights-Out (iLO) (Firmware: HPE iLO4) | ||||||||||||||||||||||||||||||||||||
Memory protection |
| ||||||||||||||||||||||||||||||||||||
Memory |
| ||||||||||||||||||||||||||||||||||||
Network controller | HPE Ethernet 1Gb 2-port 361i Adapter | ||||||||||||||||||||||||||||||||||||
Expansion slots dedicated to each server node |
| ||||||||||||||||||||||||||||||||||||
Storage controller (Dedicated to each server node) | Software RAID
SAS Controllers for external bulk drives
| ||||||||||||||||||||||||||||||||||||
Smart storage battery | HPE DL/ML/SL 96 W 145 mm smart stor battery | ||||||||||||||||||||||||||||||||||||
Internal bulk storage controller options by model | The following table shows supported controller choices for each model, per I/O module
| ||||||||||||||||||||||||||||||||||||
Internal storage devices |
| ||||||||||||||||||||||||||||||||||||
Internal storage | Apollo 4510: 1x68 Model - 68 LFF Drives per node
| ||||||||||||||||||||||||||||||||||||
Apollo 4520: 23 LFF Drives per node, 2 nodes total for a total of 46 LFF Drives per chassis
| |||||||||||||||||||||||||||||||||||||
Interfaces |
| ||||||||||||||||||||||||||||||||||||
Industry standard compliance |
| ||||||||||||||||||||||||||||||||||||
Server power cords | 6 Highline (IEC-IEC) power cord ships standard | ||||||||||||||||||||||||||||||||||||
System fans | System ships standard with 5 hot-plug fan modules | ||||||||||||||||||||||||||||||||||||
Graphics | Integrated Matrox G200 video standard
| ||||||||||||||||||||||||||||||||||||
Form factor | 4U form factor | ||||||||||||||||||||||||||||||||||||
Security |
| ||||||||||||||||||||||||||||||||||||
Insightmanagement |
| ||||||||||||||||||||||||||||||||||||
High performanceClusters (HPC) |
|
Specs 2
Software overview
Feature | Description |
|---|---|
Operating systems and virtualization software support for ProLiant servers |
|
Physical specifications
Specification | Description |
|---|---|
Dimensions (H x W x D) | 17.48 x 44.33 x 88.9 cm (6.88 x 17.45 x 35 in) |
Weight (Approximate): |
|
Technical specifications
Specification | Description | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Network interface | 10Base-T/100Base-TX/1000Base-TX | |||||||||||
Compatibility |
| |||||||||||
Data transfer method | PCI express v 3.0, 8.0 GT/s, 5.0 GT/s and 2.5 GT/s bus speeds for a x1link | |||||||||||
Controller | I350 powerville | |||||||||||
Network transfer rate |
| |||||||||||
Connector | RJ-45 | |||||||||||
Cable support |
| |||||||||||
Electrical specifications
Specification | Description |
|---|---|
Rated line voltage |
|
Rated input current |
|
Rated input frequency | 50 to 60 Hz |
Power supply output (Per power supply) | Maximum power
|
Environmental specifications
Specification | Description |
|---|---|
Operating temperature | 10° to 35°C (50° to 95°F) |
Non-operating temperature | -30° to 60°C (-22° to 140°F) |
Operating relative humidity | 10% to 90% non-condensing |
Non-operating relative humidity | 5% to 95% non-condensing |
Operating altitude | 3048 m (10,000 ft) |
Non-operating altitude | 9144 m (30,000 ft) |
Safety certifications
Specification | Description |
|---|---|
Emissions Classification (EMC) | |
FCC rating | Class A |
Normative standards | CISPR 22; EN55022; EN55024; FCC CFR 47,Pt 15; ICES-003; CNS13438; K22;K24; EN61000-3-2; EN 61000-3-3; EN 60950-1; IEC60950-1 |