Base Standard Capabilities
Product features
Feature | Description | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Processor | One of the following depending on model: E5-4600 v4 Series processors
E5-4600 v3 Series processors
| |||||||||||||||
Cache memory | One of the following depending on model:
| |||||||||||||||
NOTE:
| ||||||||||||||||
Upgradeability | Upgradeable to four (4) processors | |||||||||||||||
Chipset |
| |||||||||||||||
On system management chipset | HPE iLO (Firmware HPE iLO4 2.0), 4GB NAND with 1GB USB user space configurable VIA UEFI and accessible VIA iLO | |||||||||||||||
Memory protection |
| |||||||||||||||
Memory |
| |||||||||||||||
Network controller |
Standard iLO network controller: One (1) 10/100 Mb/s port for the HPE iLO 4 to onboard administrator link. The onboard administrator (With 10/100/1000 Mb/s) to BladeSystem link is 1 Gb/s. | |||||||||||||||
NOTE:
| ||||||||||||||||
Expansion slots | Three (3) I/O expansion mezzanine slots:
Mezzanine card options include:
| |||||||||||||||
NOTE:
| ||||||||||||||||
Server ROM | The HPE ProLiant ROM is used to configure:
| |||||||||||||||
Server UEFI/Legacy ROM | UEFI Is an industry standard that provides better manageability andmore secured configuration while interacting with users server at boot time. HPE ProLiant Gen9 platform defaults to UEFI and can be factory or field configured for legacy BIOS boot mode. UEFI Enables numerous new capabilities specific to HPE ProLiant servers
| |||||||||||||||
NOTE:
| ||||||||||||||||
Storage controller (All BTO models) | One (1) HPE Smart Array P246br Controller with 1GB Flash Backed Write Cache (FBWC) supporting RAID 0, 1, and 5 | |||||||||||||||
NOTE: The HPE Smart Array P246br and the HPE B140i (Chipset SATA). Support four (4) Small Form Factor (SFF) hot plug drive bays. | ||||||||||||||||
Maximum internal storage | One of the following depending on model:
NOTE:
| |||||||||||||||
Interfaces |
| |||||||||||||||
Industry standard compliance |
| |||||||||||||||
Enclosures | Hewlett Packard Enterprise offers two different c-Class server blade enclosures to meet users individual needs:
Server blades, interconnect modules, power supplies, fans and redundant onboard administrator modules are all designed to fit into the c3000 and c7000 enclosures. | |||||||||||||||
Graphics | Integrated Matrox G200eh video controller
HPE iLO Management on system management memory
| |||||||||||||||
Form factor | HPE ProLiant BL660c Gen9 is a full-height server blade that plugs into the HPE BladeSystem c3000 and c7000 enclosures | |||||||||||||||
Embedded management |
| |||||||||||||||
Server utilities |
| |||||||||||||||
Security |
| |||||||||||||||
Fibre channel support | Up to three (3) optional fibre channel mezzanine HBAs are supported on the HPE ProLiant BL660c Gen9 | |||||||||||||||
Compatible SAN |
| |||||||||||||||
Server management |
| |||||||||||||||
High performance clusters |
|
Specs 1
Software overview
Feature | Description |
---|---|
Operating systems and virtualization software support for ProLiant servers |
|
Physical specifications
Specification | Description |
---|---|
Dimensions (H x W x D) | With bezel: 366.27 x 56.54 x 516.67 mm (14.42 x 2.23 x 20.34 in) |
Weight (Approximate) |
|
Environmental specifications
Specification | Description |
---|---|
System inlet temperature | Operating: 10° to 35°C (50° to 95°F) At sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1,000 ft) above sea level to a maximum of 3,050 m (10,000 ft), no direct sustained sunlight Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed System performance may be reduced if operating with a fan fault or above 30°C (86°F). |
Non-operating: -30° to 60°C (-22° to 140°F) Maximum rate of change is 20°C/hr (36°F/hr) | |
Relative Humidity (Non-Condensing) | Operating: 10 to 90% Relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature |
Non-operating: 5 to 95% Relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature | |
Extended ambient operating support | For Approved hardware configurations, the supported system inlet range is extended to be: 5° to 10°C (41° to 50°F) and 35° to 40°C (95° to 104°F) At sea level with an altitude derating of 1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3050 m (10,000 ft) |
Altitude | Operating: 3,050 m (10,000 ft) This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1,500 ft/min) |
Non-operating: 9,144 m (30,000 ft) Maximum allowable altitude change rate is 457 m/min (1,500 ft/min) |