2U rack server
Processor | Max: 32 Cores2x Gen 4 Intel Xeon Scalable
Memory | Max: 1TB16 ECC DDR5 RDIMM 4800Mhz
Storage | Max: 244.48TBFront bays:
0 drive bay
Up to 8 x 3.5" SAS/SATA (HDD/SSD) Max: 160 TB
Up to 12 x 3.5" SAS/SATA (HDD/SSD) Max: 240 TB
Up to 8 x 2.5" SAS/SATA/NVMe (HDD/SSD) Max: 122.88 TB
Up to 16 x 2.5" SAS/SATA (HDD/SSD) Max: 121.6 TB
Up to 16 x 2.5" (SAS/SATA) + 8 x 2.5" (NVMe) Max: 244.48 TB
Rear bays:
Up to 2 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) Max: 30.72 TB
(supported only with 12 x 3.5" SAS/SATA HDD/SSD configuration)
Boot Optimized Server Storage (BOSS-N1) Hot-Swap
USB
S160 (SATA/NVMe SW RAID)
H355, H755, H755N, H965i, HBA355i, HBA355e, H965e
2 x 1GbE LOM card with BCM5720 LAN controller
Networking Options | Max Speed: 4x 25GbE PortsOCP 3.0 x8 Mezz 3.0
Remote Management:iDRAC9 with Lifecycle Controller
PCIe Slots:1 CPU Config: Up to 4 PCIe slots (2 x8 Gen5, 1 x16 Gen4, 1 x8 Gen4)
2 CPU config: Up to 6 PCIe slots (2 x16 Gen5, 3 x16 Gen4, 1 x8 Gen4)
2 x 75 W SW, LP
- Dell PowerEdge R710
- Dell PowerEdge R720
- Dell PowerEdge R720XD
- Dell PowerEdge R730
- Dell PowerEdge R730XD
- Dell PowerEdge R740
- Dell PowerEdge R740XD
- Dell PowerEdge R740XD2
- Dell PowerEdge R7415
- Dell PowerEdge R7425
- Dell PowerEdge R750
- Dell PowerEdge R750XA
- Dell PowerEdge R750XS
- Dell PowerEdge R7515
- Dell PowerEdge R7525
- Dell PowerEdge R760
- Dell PowerEdge R760XA
- Dell PowerEdge R760XS
- Dell PowerEdge R760XD2
- Dell PowerEdge R7615
- Dell PowerEdge R7625
(Click to View)
- Database
- Virtual Desktop Interface (VDI)
- Virtualization
- Virtual Machines (VM)
The new Dell PowerEdge R760xs is a 2U, two-socket rack server. Buy the best fit in scalable performance and large storage capability with this purpose-built 2U system. Focused on delivering the latest technology to power the most popular applications and workloads used by businesses today, including virtual desktop infrastructure (VDI), virtual machines (VMs), and software-defined storage (SDS). All delivered in a thoughtfully crafted platform that will provide balanced compute that fits in your current infrastructure.
Maximize your workload performance and boost outcomes with scale as you grow to compute, flexibly supporting a wide range of GPUs in a dual-socket/2U air-cooled server, accelerating applications from AI training and inferencing to Digital Twins to performance graphics and dense power-user collaboration environments.
- Add up to two 4th generation Intel® Xeon® Scalable processors with up to 32 cores per socket for faster performance
- Accelerate in-memory workloads with up to 16 DDR5 RDIMMS up to 4800 MT/sec
- Improve data throughput and reduce latency with support up to 8 I/O device (up to available 6 PCIe slots, 1 OCP 3.0 networking slot, and 1 dedicated PERC slot)
- Storage options include up to 12x 3.5” HDDs/SSDs, or up to 16x 2.5” HDD/SSDs, plus up to 8x NVMe drives
A breeze to cool
The 6 hot swappable fans come in 3 different types. Standard (STD) fans or the High performance Silver (HPR) fans or the High performance Gold (VHP) fans. Most configurations have the Standard Fan kit, If you install the BOSS-N1, GPU, or Rear Drives, Fan 1 will be upgraded to a GOLD fan. Below is a table outlining each config.
- Thoughtfully designed to fit in your current air-cooled infrastructure
- Alleviate the worry about expensive liquid cooling retrofitting to your data center
- Synchronize your workload needs with a tailored performance configuration that is air cooled
- Minimize the carbon footprint of your data center by better matching the system power consumption with anticipated workload requirements
The Dell OpenManage™ systems management portfolio delivers a secure, efficient, and comprehensive solution for PowerEdge servers. Simplify, automate and centralize one-to-many management with the OpenManage Enterprise console and iDRAC.
Security is integrated into every phase of the PowerEdge lifecycle, including protected supply chain and factory-to-site integrity assurance. Silicon-based root of trust anchors end-to-end boot resilience while Multi-Factor Authentication (MFA) and role-based access controls ensure trusted operations
Dell PowerEdge R760XS Base Knowledge
Strike the right balance between performance and flexibility with this air-cooled solution designed for the most popular IT applications.
- Add up to two 4th generation Intel® Xeon® Scalable processors with up to 32 cores per socket for faster performance
- Accelerate in-memory workloads with up to 16 DDR5 RDIMMS up to 4800 MT/sec
- Improve data throughput and reduce latency with support up to 8 I/O devices
- Up to 6 PCIe slots, 1 OCP 3.0 networking slot, and 1 dedicated PERC slot
- Storage options include up to 12 x 3.5” HDDs/SSDs; or up to 16 x 2.5” HDD/SSDs, plus up to 8 x NVMe drives
All models support the BOSS option, with the exception of the 12 Bay Chassis. All other options support up to 2 GPUs if both CPUs are installed. The 12 Bay is the only config to support the rear bay option.
Drives Configurations:- 0 drive bay
- 8x 3.5" SAS/SATA
- 12x 3.5" SAS/SATA + 2x 2.5" SAS/SATA/NVMe
- 8x 2.5" SAS/SATA
- 8x 2.5" NVMe
- 16x 2.5" SAS/SATA
- 16x 2.5" SAS/SATA + 8x 2.5" NVMe
Rear Bay Drive Options:
Only Supported on the 12 Bay Chassis. The rear-drive module doesn't support Kioxia CM6 series, Samsung PM1735 series, Hynix PE8010 7.68TB, Samsung PM1733a > 1.92TB, Samsung PM1735a > 1.6TB and Redtail NVMe drive.
Drives Supported in Rear- SAS (HDD/SSD)
- SATA (HDD/SSD)
- NVME (SSD)
- Max Drive Capacity: 30.72TB
NOTE:
The 16x 2.5" SAS/SATA backplane configuration is a combination of two 8x 2.5" SAS/SATA backplanes. (8 + 8)
Limitations with the 12 LFF Chassis
The 12 Bay Chassis has some major restrictions with Thermal and what gear can be installed.
- Cannot support PCIe card with the cooling requirement of more than 300LFM at 55C.
- Cannot support OCP card with a cooling requirement of more than 250LFM at 55C
(3Y64D / 4TRD3 / GGGDF / R1KTR / Y4VV5) . - Solarflare Melrose DP 25 GBE SFP28 (TTKWY) not supported.
- 100 Gb network adapter or 100 Gb OCP is not supported.
- The 12 Bay Chassis requires the optical transceiver with higher temperature spec (≥ 85°C) to support (M14MK / N8TDR).
- The 12 Bay Chassis is the only one to support the rear drive cage.

The following lists the features and functions that are in the upcoming 4th Generation Intel® Xeon Scalable Processor offering:
- Faster UPI with up to four Intel Ultra Path Interconnect (Intel UPI) at up to 16 GT/s, increasing multi-socket bandwidth.
- More, faster I/O with PCI Express 5 and up to 80 lanes (per socket)
- Enhanced Memory Performance with DDR5 support and memory speed up to 4800 MT/s in one DIMM per channel (1DPC) and 4400 MT/s in two DIMM per channel (2DPC)
- New built-in accelerators for data analytics, networking, storage, crypto, and data compression

The Dell R760XS Rack Server has 2 Heatsinks options that will change based on the TDP of the Processors. The Dell R760xs also has 3 different types of Fans; Standard, Silver, and Gold Fans. These fans will be changed based on other components installed. Below is a table outlining those changes.
Heatsink (HSK) TDP Rules
If the processor's TDP is below 185W an STD HSK will be installed otherwise the Highperformance HSK will be installed.
Except the 12 Bay Chassis with a Processor that has a TDP below 125W supports the Standard Heatsink.
Fan Config Rules
Optional fan zone 1 has to be populated with HPR Gold fan for BOSS, GPU, or rear drive module populations. A fan blank is required on fan zone 1 when no fan is populated
Fan population rule for Dell PowerEdge R760xs
| Configuration | No backplane | 8x 3.5" SAS | 12x 3.5" SAS | 8x 2.5" SAS | 8x 2.5" NVMe | 16x 2.5" SAS | 24x 2.5" (16x 2.5" + 8x 2.5" NVMe) |
|---|---|---|---|---|---|---|---|
| Default | Fan 2 to Fan 6 with STD fan | Fan 2 to Fan 6 with STD fan | Fan 2 to Fan 6 with HPR Silver fan | Fan 2 to Fan 6 with STD fan | Fan 2 to Fan 6 with HPR Silver fan | Fan 2 to Fan 6 with STD fan | Fan 2 to Fan 6 with HPR Silver fan |
| Rear Module | Not Supported | Not Supported | Fan 2 to Fan 6 with HPR Silver fan | Not Supported | Not Supported | Not Supported | Not Supported |
| BOSS-N1 | Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan | Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan | Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan | Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan | Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan | Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan | Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
| GPU | Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan | Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan | Not Supported | Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan | Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan | Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan | Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
The Dell R760XS Rack Server on a two-socket configuration supports 16 DDR5 DIMM slots. Up to 1TB of RDIMM with speeds up to 4800 MT/s and supports registered ECC DDR5 DIMMs only.
- All DIMMs must be DDR5
- Memory mixing is not supported for different DIMM capacities.
- A minimum of 1 DIMM must be populated for each installed processor.
| DIMM type | Rank | Capacity | Single processor | Dual processors | DIMM rated voltage and speed | Operating Speed | ||
|---|---|---|---|---|---|---|---|---|
| Minimum memory capacity | Maximum memory capacity | Minimum memory capacity | Maximum memory capacity | 1 DIMM per channel (DPC) | ||||
| RDIMM | Single Rank | 16 GB | 16 GB | 128 GB | 32 GB | 256 GB | DDR5 (1.1 V), 4800 MT/s | 4800 MT/s |
| Dual Rank | 32 GB | 32 GB | 256 GB | 64 GB | 512 GB | DDR5 (1.1 V), 4800 MT/s | 4800 MT/s | |
| 64 GB | 64 GB | 512 GB | 128 GB | 1 TB | DDR5 (1.1 V), 4800 MT/s | 4800 MT/s | ||
The LOM and OCP are great ways to expand the networkability of the server. The LOM is built into the system board and supports 2x 1GbE ports. While the Optional OCP 3.0 supports 4 ports up to speeds of 25Gb/s. If the OCP card is installed without the rear riser, The OCP air shroud must be installed.
These networking slots don’t take up a PCIe lane which allows you more flexibility and freedom to configure your server how you see fit. If you have any concerns about the right card for your build. Please reach out to us via email or chat.
LOM Ports:
1 GB x 2
OCP Ports:1 GbE x 4, 10 GbE x 2, 10 GbE x 4, 25 GbE x 2, 25 GbE x 4

This system can support Single or Dual processors configurations. Based on the Socket configuration the sytem can hold from 2 LP Gen 4 slots. Up to 6 PCIe slots rangeing from x8 Gen4 to x16 Gen5. Only one cable riser can be installed at a time in any given configuration.
Slots 1, 2, 5, and 6 are Gen4 slots, slots 3 and 4 located on risers are Gen5 slots.
| Configurations | Expansion card risers | PCIe Slots | Controlling processor | Height | Length | Slot width | Power |
|---|---|---|---|---|---|---|---|
| Config 0-1. | No riser | 1, 2 | Processor 1 | Low profile | Half length | x16, x8 | 75 W |
| Config 0-2. | No riser | 1, 2 | Processor 1 | Low profile | Half length | x16, x8 | 75 W |
| No riser | 5, 6 | Processor 2 | Low profile | Half length | x16, x16 | 75 W | |
| Config 1. | R1C | 1, 2, 3 | Processor 1 | Low profile | Half length | x16, x8, x16 | 75 W |
| 4, 5, 6 | Processor 2 | Low profile | Half length | x16, x16, x16 | 75 W | ||
| Config 2. | R1D | 1, 2, 3, 4 | Processor 1 | Low profile | Half length | x16, x8, x8, x8 | 75 W |
NOTE: The Adapter PERC is only available with 12 x 3.5-inch SAS/SATA backplane configuration. All the other Chassis will have an fPERC , Rear Mounted installed for RAID and SAS control.
| Performance Level | Controller and Description |
|---|---|
| Software | NA (No SW RAID) |
| Internal | H355, H755, H965i |
| External | H965e, |
| SAS Host Bust Adapters (HBA) | HBA355i, HBA355e |
Storage Controller Specs
| Model & Form Factors | Interface Support | PCI Support | SAS Connection | Cache Memory Size | Write Back Cache | RAID Levels | Max Drive Support | RAID Support |
|---|---|---|---|---|---|---|---|---|
| PowerEdge Server-Storage Controllers (PERC) Series 12 | ||||||||
| H965i Front | 24Gb/s SAS 6Gb/s SAS/SATA Gen3 (8 GT/s) NVMe Gen4 (16 GT/s) NVMe |
PCIe Gen 4 | 16 ports/lanes - 2x8 Internal | 8GB NV | Flash Backed Cache | 0,1,5,6,10,50,60 | 16 | Hardware |
| H965i Adapter | 24Gb/s SAS 6Gb/s SAS/SATA Gen3 (8 GT/s) NVMe Gen4 (16 GT/s) NVMe |
PCIe Gen 4 | 16 ports/lanes - 2x8 Internal | 8GB NV | Flash Backed Cache | 0,1,5,6,10,50,60 | 16 | Hardware |
| S160 Software RAID | Gen4 (16 GT/s) NVMe | PCIe Gen 4 | N/A | No Cache | No Cache | 0,1,5,10 | 8 | Software RAID - Windows Only |
| PowerEdge Server-Storage Controllers (PERC & SAS HBA) Series 11 | ||||||||
| H755 Adapter | 12Gb/s SAS 6Gb/s SAS/SATA 3Gb/s SAS/SATA Gen3 (8 GT/s) NVMe Gen4 (16 GT/s) NVMe |
PCIe Gen 4 | 16 ports- 2x8 Internal | 8GB NV | Flash Backed Cache | 0,1,5,6,10,50,60 | 16 Per Controller / 50 with SAS Expander | Hardware |
| H755N Front (NVMe Only) |
Gen3 (8 GT/s) NVMe Gen4 (16 GT/s) NVMe | PCIe Gen 4 | 16 ports- 2x8 Internal | 8GB NV | Flash Backed Cache | 0,1,5,6,10,50,60 | 8 Per Controller | Hardware |
| H755 Front (SAS/SATA only) |
12Gb/s SAS 6Gb/s SAS/SATA 3Gb/s SAS/SATA |
PCIe Gen 4 | 16 ports- 2x8 Internal | 8GB NV | Flash Backed Cache | 0,1,5,6,10,50,60 | 16 Per Controller / 50 with SAS Expander | Hardware |
| HBA355i Adapter | 12Gb/s SAS 6Gb/s SAS/SATA 3Gb/s SAS/SATA |
PCIe Gen 4 | 16 ports- 2x8 Internal | N/A | N/A | N/A | 16 Per Controller / 50 with SAS Expander | N/A |
| HBA355i Front | 12Gb/s SAS 6Gb/s SAS/SATA 3Gb/s SAS/SATA |
PCIe Gen 4 | 16 ports- 2x8 Internal | N/A | N/A | N/A | 16 Per Controller / 50 with SAS Expander | N/A |
| HBA355e Adapter | 12Gb/s SAS 6Gb/s SAS/SATA 3Gb/s SAS/SATA |
PCIe Gen 4 | 16 ports- 4x4 external | N/A | N/A | N/A | 240 | N/A |
| H355 Adapter | 12Gb/s SAS 6Gb/s SAS/SATA |
PCIe Gen 4 | 16 ports- 2x8 Internal | No Cache | No Cache | 0,1, 10 | Up to 32 RAID, or 32 Non- RAID |
Hardware |
| H355 Front | 12Gb/s SAS 6Gb/s SAS/SATA |
PCIe Gen 4 | 16 ports- 2x8 Internal | No Cache | No Cache | 0,1, 10 | Up to 32 RAID, or 32 Non- RAID |
Hardware |
Up to 2 60MM Hot-swap Redundant Power Supplies
- 1800 W Titanium 200—240 VAC or 240 HVDC
- 1400 W Platinum 100—240 VAC or 240 HVDC
- 1100 W Titanium 100—240 VAC or 240 HVDC
- 1100 W LVDC -48 — (-60) VDC
- 800 W Platinum 100—240 VAC or 240 HVDC
- 700 W Titanium 200—240 VAC or 240 HVDC
- 600 W Platinum 100—240 VAC or 240 HVDC
Width: 482 mm (18.97 inches)
Height: 86.8 mm (3.41 inches)
Length: 707.78 mm (27.85 inches) – without bezel
Length: 721.62 mm (28.4 inches) – with bezel
Weight Per Chassis:
16+8 x 2.5-inch - 25.92 kg (57.14 lb)
16 x 2.5-inch - 24.58 kg (54.18 lb)
12 x 3.5-inch - 28.82 kg (63.53 lb)
8 x 3.5-inch - 25.84 kg (54.96 lb)
8 x 2.5-inch - 21.56 kg (47.53 lb)
Driveless - 19.40 kg (42.76 lb)
Current Configuration
(List below serves as quick links to each section)
Select Chassis
Select Processor
Bezel
Memory
Storage Devices
Rear Drive cages
LFF SAS Drives
LFF SATA Drives
SFF SAS Drives
SFF SATA Drives
2.5" U.2 Gen4 NVMe
Riser Card
OCP NIC
GPU
TPM
Rail Kit
iDRAC 9
Power Supply Unit
ECS Warranty
The request has been sent.
Thank you.
Price as Configured:
$0
Base Standard Capabilities
| Feature | Technical Specifications | |
|---|---|---|
| Processor | Up to two 4th Generation Intel Xeon Scalable processor with up to 32 cores per processor | |
| Memory | • 16 DDR5 DIMM slots, supports RDIMM 1 TB max, speeds up to 4800 MT/s, supports registered ECC DDR5 DIMMs only | |
| Storage controllers | • Internal Controllers: PERC H965i, PERC H755, PERC H755N, PERC H355, HBA355i • Internal Boot: Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 1, 2 x M.2 NVMe SSDs or USB • External HBA (non-RAID): HBA355e; Software RAID: S160 | |
| GPU Options | 2 x 75 W SW, LP | |
| Drive Bays | Front bays: • 0 drive bay • Up to 8 x 3.5-inch SAS/SATA (HDD/SSD) max 160 TB • Up to 12 x 3.5-inch SAS/SATA (HDD/SSD) max 240 TB • Up to 8 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 122.88 TB • Up to 16 x 2.5-inch SAS/SATA (HDD/SSD) max 121.6 TB • Up to 16 x 2.5-inch (SAS/SATA) + 8 x 2.5-inch (NVMe) (HDD/ SSD) max 244.48 TB | Rear bays: • Up to 2 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 30.72 TB (supported only with 12 x 3.5-inch SAS/SATA HDD/SSD configuration) |
| Hot swap Redundant Power Supplies | • 1800 W Titanium 200—240 VAC or 240 HVDC • 1400 W Platinum 100—240 VAC or 240 HVDC • 1100 W Titanium 100—240 VAC or 240 HVDC • 1100 W LVDC -48 — (-60) VDC • 800 W Platinum 100—240 VAC or 240 HVDC, • 700 W Titanium 200—240 VAC or 240 HVDC • 600 W Platinum 100—240 VAC or 240 HVDC | |
| Cooling Options | • Air cooling | |
| Fans | • Standard (STD) fans/High performance Silver (HPR) fans/ High performance Gold (VHP) fans, Up to 6 hot swappable fans | |
| Dimensions and Weight | • Height – 86.8 mm (3.41 inches) • Width – 482 mm (18.97 inches) • Depth – 707.78 mm (27.85 inches) – without bezel 721.62 mm (28.4 inches) – with bezel • Weight – Max 28.6 kg (63.0 lbs.) | |
| Form Factor | 2U rack server | |
| Embedded Management | • iDRAC9 • iDRAC Direct • iDRAC RESTful API with Redfish • iDRAC Service Module • Quick Sync 2 wireless module | |
| Bezel | Optional LCD bezel or security bezel | |
| OpenManage Software | • CloudIQ for PowerEdge plug in • OpenManage Enterprise • OpenManage Enterprise Integration for VMware vCenter • OpenManage Integration for Microsoft System Center • OpenManage Integration with Windows Admin Center • OpenManage Power Manager plugin • OpenManage Service plugin • OpenManage Update Manager plugin | |
| Mobility | OpenManage Mobile | |
| OpenManage Integrations | • BMC Truesight • Microsoft System Center • OpenManage Integration with ServiceNow • Red Hat Ansible Modules • Terraform Providers • VMware vCenter and vRealize Operations Manager | |
| Security | • Cryptographically signed firmware • Data at Rest Encryption (SEDs with local or external key mgmt) • Secure Boot • Secure Erase • Secured Component Verification (Hardware integrity check) • Silicon Root of Trust • System Lockdown (requires iDRAC9 Enterprise or Datacenter) • TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ | |
| Embedded NIC | 2 x 1 GbE LOM | |
| Network options | 1 x OCP card 3.0 (optional) | |
| Ports | Front Ports: • 1 x iDRAC Direct (Micro-AB USB) port, 1 x USB 2.0, 1 x VGA Internal Ports: 1 x USB 3.0 (optional) | Rear Ports • 1 x Dedicated iDRAC Ethernet port, 1 x USB 2.0, 1 x USB 3.0, 1 x VGA, 1 x Serial (optional) |
| PCIe | • 1 CPU Configuration: Up to 4 PCIe slots (2 x8 Gen5, 1 x16 Gen4, 1 x8 Gen4) • 2 CPU configuration: Up to 6 PCIe slots (2 x16 Gen5, 3 x16 Gen4, 1 x8 Gen4) | |
| Operating System and Hypervisors | • Microsoft Windows Server with Hyper-V • Red Hat Enterprise Linux • SUSE Linux Enterprise Server • VMware ESXi • Canonical Ubuntu Server LTS | |
Spec Sheet 4
| Feature | PowerEdge R760xs | PowerEdge R750xs |
|---|---|---|
| Processor | Maximum two 4th Generation Intel® Xeon® Scalable processors with maximum 32 cores per processor | Maximum two 3rd Generation Intel® Xeon® Scalable processors with maximum 32 cores per processor |
| Processor Interconnect | Intel Ultra Path Interconnect (UPI) , up to 3 links per CPU | Intel Ultra Path Interconnect (UPI) |
| Memory | 16 DDR5 DIMM slots Supports RDIMM 1TB max Speed maximum 4800 MT/s Supports registered ECC DDR5 DIMMs only NVDIMM : No |
16 DDR4 DIMM slots Supports RDIMM 1 TB max Speed maximum 3200 MT/s Supports registered ECC DDR4 DIMMs only Apache Pass : No NVDIMM : No |
| Storage Drives | Front bays: â— 0 drive bay â— Maximum 8x 3.5-inch SAS/SATA (HDD/ SSD) max 160 TB â— Maximum 12x 3.5-inch SAS/SATA (HDD/ SSD) max 240 TB â— Maximum 8x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 122.88 TB â— Maximum 16x 2.5-inch SAS/SATA (HDD/ SSD) max 121.6 TB â— Maximum 16x 2.5-inch (SAS/SATA) + 8x 2.5- inch (NVMe) (HDD/SSD) max 244.48 TB |
Front bays: â— 0 drive bay â— Maximum 8x 3.5-inch SAS/SATA (HDD/SSD) max 128 TB â— Maximum 12x 3.5-inch SAS/SATA (HDD/SSD) maximum 192 TB â— Maximum 8x 2.5-inch SAS/SATA/NVMe (HDD/ SSD) maximum 61.44 TB â— Maximum 16x 2.5-inch SAS/SATA (HDD/SSD) maximum 122.88 TB â— Maximum 16x 2.5-inch (SAS/SATA) + 8x 2.5- inch (NVMe) (HDD/SSD) maximum 184.32 TB |
| Rear bays: â— Maximum 2x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 30.72 TB |
Rear bays: â— Maximum 2x 2.5-inch SAS/SATA/NVMe (HDD/ SSD) maximum 15.36 TB |
|
| Storage Controllers | Internal controllers: H965i, HBA465i ( post RTS),
H755, H755N, H355, HBA355i Internal Boot: Internal Dual SD Module or Boot Optimized Storage Subsystem (BOSS N1): HWRAID 2x M.2 SSDs and Internal USB External: 965e (post RTS), HBA 355e Software RAID: S160 |
Internal controllers: PERC H345, PERC H355,
PERC H745, PERC H755, PERC H755N, HBA355i Internal Boot: Internal Dual SD Module or Boot Optimized Storage Subsystem (BOSS S2): HWRAID 2x M.2 SSDs or Internal USB External PERC (RAID): PERC H840, HBA355e Software RAID: S150 |
| PCIe SSD | Front: Maximum 16 x 2.5-inch (NVMe drives) | Maximum 16 x 2.5-inch (NVMe drives) |
| Rear: Up to 2 x 2.5-inch NVMe | ||
| PCIe Slots | Up to 6 PCIe slots (2 x Gen5, 4 x Gen4) | Up to 6 PCIe slots (5 x Gen4, 1 x Gen5) |
| Embedded NIC (LOM) | 2x 1GbE LOM | 2x 1GbE LOM |
| Networking Options (OCP 3.0) | Rear: 1 x OCP 3.0 (x8 PCIe lanes) | Maximum 1 OCP 3.0 |
| GPU | Nvidia A2 (60 W, LP) | Not supported |
| USB Ports | Front ports â— 1x Dedicated iDRAC micro-USB â— 1x USB 2.0 â— 1x VGA |
Front ports â— 1x Dedicated iDRAC micro-USB â— 1x USB 2.0 â— 1x VGA |
| Rear ports: â— 1x USB 2.0 â— 1x Serial (optional) â— 1x USB 3.0 â— 2x Ethernet â— 1x VGA |
Rear ports: â— 1x USB 2.0 â— 1x Serial (optional) â— 1x USB 3.0 â— 2x Ethernet â— 1x VGA |
|
| Internal port: â— 1x USB 3.0 (optional) |
Internal port: â— 1x USB 3.0 (optional) |
|
| Rack Height | 2U rack server | 2U rack server |
| Power Supplies | ◠1800 W Platinum 100–240 VAC/ 240 VDC ◠1400 W Platinum 100–240 VAC/ 240 VDC ◠1100 W Titanium 100–240 VAC/ 240 VDC ◠1100 W DC/-48–(-60) V ◠800 W Platinum 100–240 VAC/ 240 VDC ◠700 W Titanium 200–240 VAC/240 VDC ◠600 W Platinum 100–240 VAC/ 240 VDC |
◠1800 W Platinum 100–240 VAC/ 240 VDC ◠1400 W Platinum 100–240 VAC/ 240 VDC ◠1100 W Titanium 100–240 VAC/ 240 VDC ◠1100 W DC/-48–(-60) V ◠800 W Platinum 100–240 VAC/ 240 VDC ◠700 W Titanium 200–240 VAC/240 VDC ◠600 W Platinum 100–240 VAC/ 240 VDC |
| System Management | â— Lifecycle Controller 3.x â— OpenManage â— QuickSync 2.0 â— OpenManage Enterprise Power Manager â— Digital License Key â— iDRAC Direct (dedicated micro-USB port) â— Easy Restore |
â— Lifecycle Controller 3.x â— OpenManage â— QuickSync 2.0 â— OpenManage Enterprise Power Manager â— Digital License Key â— iDRAC Direct (dedicated micro-USB port) â— Easy Restore |
| Availability | Hot-plug drives Hot-plug redundant cooling Hot-plug redundant power supplies BOSS-N1 |
Hot-plug drives Hot-plug redundant cooling Hot-plug redundant power supplies IDSDM BOSS S2 |