Spec Sheet 4
| Feature | Technical Specifications | |
|---|---|---|
| Processor | Two Intel Xeon 6 Processors with up to 144 E-cores or 86 P-cores per processor | |
| Memory |
• 32 DDR5 DIMM slots, supports RDIMM 8 TB max, speeds up to 6400 MT/s • Supports registered ECC DDR5 DIMMs only |
|
| Storage controllers |
• Internal Boot: (BOSS-N1): HWRAID 1, 2 x M.2 NVMe SSDs • (BOSS-N1 DC-MHS): M.2 Interposer board (DC-MHS): 2 x M.2 NVMe SSDs • USB • Internal controllers: Front PERC H965i, Front PERC H975i, Front PERC H365i |
|
| Front Bays |
• No backplane configuration • Up to 8 x EDSFF E3.S Gen5 NVMe max 122.88 TB also comes with FIO configuration • Up to 16 x EDSFF E3.S Gen5 NVMe max 245.76 TB also comes with FIO configuration • Up to 32 x EDSFF E3.S Gen5 NVMe max 489.6 TB • Up to 8 x 2.5 inch SAS/SATA/NVMe max 122.88 TB • Up to 8 x 2.5-inch Universal max 245.6 TB • Up to 16 x 2.5 inch SAS/SATA max 61.44 TB • Up to 24 x 2.5 inch SAS/SATA max 92.16 TB • Up to 16 x 2.5 inch SAS/SATA + 8 x 2.5-inch NVME) max 92.16 TB • Up to 40 x EDSFF E3.S Gen5 NVMe max 614.4 TB • Up to 4 x EDSFF E3.S Gen5 NVMe max 61.2 TB on the rear |
|
| Hot swap Power Supplies |
• 800 W Platinum 100—240 VAC or 240 VDC • 1100 W Platinium 100—240 VAC or 240 VDC • 1500 W Titanium 100—240 VAC or 240 VDC • 1100 W Titanium 100—240 VAC or 240 VDC • 3200 W Titanium 200—240 VAC or 240 VDC • 800 W Titanium 100—240 VAC or 240 VDC • 3200 W 277 VAC and 336 HVDC Titanium* • 1400 W -48VDC 60mm* • 1500 W 277 VAC and 336 HVDC Titanium* • 2400 W Titanium 100—240 VAC or 240 VDC* • 1800 W HLAC Titanium 200—240 VAC or 240 VDC* |
|
| Cooling Options | • Air cooling and Direct Liquid Cooling • Note: DLC is a rack solution and requires rack manifolds and a cooling distribution unit (CDU) to operate. |
|
| Fans | • High performance Silver (HPR SLVR) fans / High performance Gold (HPR GOLD) fans • Up to 6 sets (dual fan module) hot swappable fans |
|
| Dimensions and Weight | Height – 86.8 mm (3.42 inches) Width – 482 mm (18.98 inches) Weight – 28.53 kg (62.89 pounds) |
Depth (for rear I/O configuration) • 802.40 mm (31.59 inches) with bezel • 801.51 mm (31.56 inches) without bezel Depth (for front I/O configuration) • 814.52 mm (32.07 inches) without bezel Note: The front I/O configuration does not support the bezel. |
| Form Factor | 2U rack server | |
| Embedded Management |
• iDRAC • iDRAC Direct • iDRAC RESTful API with Redfish • RACADM CLI • iDRAC Service Module (iSM) • Quick Sync 2 wireless module • NativeEdge Endpoint • NativeEdge Orchestrator |
|
| Bezel | Optional security bezel | |
| Security |
• Cryptographically signed firmware • Data at Rest Encryption (SEDs with local or external key mgmt) • Secure Boot • Secured Component Verification (Hardware integrity check) • Secure Erase • Silicon Root of Trust • System Lockdown • System Lockdown (requires iDRAC10 Enterprise or Datacenter) • TPM 2.0 FIPS, CC-TCG certified • Chassis Intrusion Detection |
|
| Network options | 4 x OCP NIC 3.0 cards (optional) and 1GbE, 10GbE, 25GbE, 100GbE and 400GbE* • Slot 34 1 x 16 OCP 3.0 on front riser • Slot 38 1 x 16 OCP 3.0 on front riser • Slot 4 1 x 8 or 1 x 16 Gen5 OCP 3.0 • Slot 10 1 x 8 or 1 x 16 OCP 3.0 |
|
| BOSS |
• Slot 34 1 x 4 BOSS • Slot 6 1 x 4 BOSS |
|
| GPU Options |
Up to 6 x 75 W FHHL* or up to 2 x 350 W DWFL |
|
| Ports |
Front Ports: • 1 x USB 2.0 Type C port • 1 x USB 2.0 Type A port (optional) • 1 x Mini-DisplayPort (optional) • 1 x DB9 Serial (with front I/O configuration) • 1 x Dedicated ethernet port for iDRAC management |
Rear Ports: • 1 x Dedicated ethernet port for iDRAC management • 1 x VGA • 2 x USB 3.1 Type A ports |
|
Internal Ports: • 1 x USB 3.1 Type A port |
||
| PCIe |
• Upto two PCIe slots ( x16 connectors) • Slot 31 1 x 16 Gen5 Full Height - Half Length or Full Length on front Riser • Slot 36 1 x 16 Gen5 Full Height - Half Length on front Riser • Upto eight PCIe slots (x8 and x16 connectors) • Slot 1 1 x 8 Gen5 Full Height - Half Length • Slot 2 1 x 16 Gen5 Dual Width Full Length or 1 x 8 Gen5 Full Height - Half Length • Slot 3 1 x 16 Gen5 Full Height - Half Length or 1 x 16 Gen5 Low Profile • Slot 4 1 x 16 Gen5 Full Height - Half Length or 1 x 8 Gen5 Full Height - Half Length or 1 x 8 or 1 x 16 OCP 3.0 • Slot 5 2 x 16 Gen5 Full Height - Half Length or 1 x 8 Gen5 Full Height - Half Length • Slot 7 1 x 16 Gen5 Full Height - Half Length or 1 x 16 Gen5 Dual Width Full Length or 1 x 8 Gen5 Full Height - Half Length • Slot 8 1 x 16 Gen5 Full Height - Half Length or 1 x 8 Gen5 Full Height - Half Length • Slot 9 1 x 16 Gen5 Full Height - Half Length or 1 x 8 Gen5 Full Height - Half Length or 1 x 16 Low Profile- Half Length |
|
| Operating System and Hypervisors |
• Canonical Ubuntu Server LTS • Microsoft Windows Server with Hyper-V (P-Core only) • Red Hat Enterprise Linux • SUSE Linux Enterprise Server • VMware ESXi |
|
| Feature | Technical Specifications | |
|---|---|---|
| Processor | Two Intel Xeon 6 Processors with up to 144 E-cores or 86 P-cores per processor | |
| Memory |
• 32 DDR5 DIMM slots, supports RDIMM 8 TB max, speeds up to 6400 MT/s • Supports registered ECC DDR5 DIMMs only |
|
| Storage controllers |
• Internal Boot: (BOSS-N1): HWRAID 1, 2 x M.2 NVMe SSDs • (BOSS-N1 DC-MHS): M.2 Interposer board (DC-MHS): 2 x M.2 NVMe SSDs • USB • Internal controllers: Front PERC H965i, Front PERC H975i, Front PERC H365i |
|
| Front Bays |
• No Backplane configuration • 8 x EDSFF E3.S NVMe max 122.88 TB also with FIO configuration • 16 x EDSFF E3.S Gen5 NVMe max 245.76 TB • 20 x EDSFF E3.S Gen5 NVMe max 307.2 TB • 8 x 2.5 inch SAS/SATA/NVMe Direct/NVMe Raid max 122.88 TB • 8 x 2.5-inch Universal 245.6 TB • 10 x 2.5 inch SAS/SATA max 38.4 TB • 2 x EDSFF E3.S Gen5 NVMe in the rear max 30.72 TB |
|
| Hot swap Power Supplies |
• 1500 W Titanium 100—240 VAC or 240 VDC • 1100 W Titanium 100—240 VAC or 240 VDC • 800 W Titanium 100—240 VAC or 240 VDC • 1100 W Platinum 100—240 VAC or 240 VDC • 800 W Platinum 100—240 VAC or 240 VDC • 1800 W HLAC Titanium 200—240 VAC or 240 VDC* • 1500 W 277 VAC or 336 VDC* • 1400 W LVDC -48 — -60 VDC* |
|
| Cooling Options | • Air cooling and Direct Liquid Cooling • Note: DLC is a rack solution and requires rack manifolds and a cooling distribution unit (CDU) to operate. |
|
| Fans | • High performance Silver (HPR SLVR) or Standard (STD) fans • Up to 4 sets (dual fan module) hot swappable fans |
|
| Dimensions and Weight | Height – 42.8 mm (1.69 inches) Width – 482 mm (18.98 inches) Weight – 20.42 kg (45.02 pounds) |
Depth (for rear I/O configuration) • 816.92 mm (32.20 inches) with bezel • 815.14 mm (32.09 inches) without bezel Depth (for front I/O configuration) • 829.44 mm (32.66 inches) without bezel Note: The front I/O configuration does not support the bezel. |
| Form Factor | 1U rack server | |
| Embedded Management |
• iDRAC • iDRAC Direct • iDRAC RESTful API with Redfish • RACADM CLI • iDRAC Service Module (iSM) • Quick Sync 2 wireless module • NativeEdge Endpoint • NativeEdge Orchestrator |
|
| Bezel | Optional security bezel | |
| Security |
• Cryptographically signed firmware • Data at Rest Encryption (SEDs with local or external key mgmt) • Secure Boot • Secured Component Verification (Hardware integrity check) • Secure Erase • Silicon Root of Trust • System Lockdown • TPM 2.0 FIPS, CC-TCG certified • Chassis Intrusion Detection |
|
| Network options | 4 x OCP NIC 3.0 cards (optional) and 1GbE, 10GbE, 25GbE, 100GbE and 400GbE* • Slot 31 1 x 16 OCP 3.0 on front riser • Slot 32 1 x 16 OCP 3.0 on front riser • Slot 2 1 x 16 OCP 3.0 • Slot 5 1 x 8 Gen5 OCP 3.0 or 1 x 16 Gen5 OCP 3.0 |
|
| BOSS |
• Slot 34 1 x 4 BOSS • Slot 3 1 x 4 BOSS |
|
| GPU Options | Up to 3 x 75 W SW | |
| Ports |
Front Ports: • 1 x USB 2.0 Type C port • 1 x USB 2.0 Type A port (optional) • 1 x Mini-DisplayPort (optional) • 1 x DB9 Serial (with front I/O configuration) • 1 x Dedicated ethernet port for iDRAC management |
Rear Ports: • 1 x Dedicated ethernet port for iDRAC management • 1 x VGA • 2 x USB 3.1 Type A ports |
|
Internal Ports: • 1 x USB 3.1 Type A port |
||
| PCIe |
• Up to 2 x 16 Gen5 PCIe slots • Slot 31 1 x 16 Full Height - Half Length or Full Height - Full Length or 1 x 16 OCP 3.0 on front riser • Slot 32 1 x 16 Full Height - Half Length or Full Height - Full Length or 1 x 16 OCP 3.0 on front riser • Up to 3 x 16 or 2 x 8 Gen5 PCIe slots • Slot 1 1 x 16 Full Height - Half Length or Full Height - Full Length or 3 x 16 or 1 x 8 Low Profile - Half Length • Slot 2 1 x 16 or 1 x 8 Low Profile - Half Length or 1 x 16 OCP 3.0 • Slot 4 1 x 16 Full Height - Half Length or 1 x 16 Low Profile - Half Length |
|
| Operating System and Hypervisors |
• Canonical Ubuntu Server LTS • Microsoft Windows Server with Hyper-V (P-Core only) • Red Hat Enterprise Linux • SUSE Linux Enterprise Server • VMware ESXi |
|