- Up to 4 Intel® Xeon® 6 Performance-Core (P-Core) processors (8 to 86 cores per processor)
- 64 DDR5 DIMM slots (16 per processor) – maximum memory 16 TB
- Fans typically 4 dual-rotor hot-plug redundant fans (8 rotors total)
- Up to 32 SFF or
up to 32 EDSFF E3.S NVMe drives
(mixed SFF/EDSFF configurations also supported, depending on drive cage layout) - Up to 12 PCIe Gen5 slots (full-height, ¾-length)
- 2x OCP 3.0 slots (rear only)
- Up to 4 Power supplies (1500W, 2400W, or 3200W; 1+1, 2+2, or 3+1 hot-plug redundant HPE Flexible Slot Power Supplies)
- HPE NS204i-u Boot Device V2 (front or rear install options)
- HPE iLO 7 management
(Click to View)
The HPE ProLiant Compute DL580 Gen12 is a high-density, four-socket 4U server built for data-intensive workloads like databases, analytics, and big data. It's powered by Intel Xeon 6 processors (up to 86 cores) and up to 16 TB of DDR5 memory at speeds up to 6400 MT/s, delivering up to 2x higher general-compute performance than previous generations. New upgrades include support for up to 32 mixed SFF/EDSFF E3.S drives, an optional front-accessible NS204i-u boot device, up to 12 PCIe Gen5 slots plus two OCP 3.0 slots, and an available Direct Liquid Cooling module. It's managed via HPE iLO 7, which adds a hardware-based secure enclave and quantum-resistant firmware signing for enhanced security.

- 4U rack chassis (single chassis design)
- 6 front box options for drive/media bay configurations
- Up to 4 Intel® Xeon® 6 processors
- 64 DDR5 DIMM slots – maximum memory 16 TB
- Dimensions:
- Height: 17.47 cm (6.88 in)
- Width: 44.78 cm (17.63 in)
- Depth: 80.26 cm (31.60 in)
- Weight: 28.79–48.75 kg (63.48–107.49 lbs)
8SFF x1 U.3 TM KitP80429-B21
8SFF x4 U.3 TM KitP80430-B21
SFF Universal Media BayP80447-B21
2 SFF U.3 Drive CageP80432-B21
- P80429-B21 – Max 4; requires a Tri-Mode controller
- P80430-B21 – Max 4; Supports Direct Attached (no controller, NVMe only) or Tri-Mode controller
- P80447-B21 – Requires Box 1 to be unused
- The Universal Media Bay installed, max drive cages is 3
- The Universal Media Bay and NS204i-u Front Kit installed, Max Drive Cage 1 in Box 3
- The P80432-B21 requires the UBM P80447-B21 to be installed
- And ODD requires the UBM P80447-B21 to be installed

- no RAID/tri-mode controller required or supported
- Cable Kit P80400-B21 required for a single 8EDSFF cage installed in Box 3
- Up to 32 EDSFF E3.S drives when four 8EDSFF cage
- Must have 4 Sockets
- if a Universal Media Bay Kit is installed, drive support is limited to 8SFF/8EDSFF (Box 3 only)
- NS204i-u boot device (Front Enablement Kit) is installed, the cage in Box 4 is relocated to Box 1
- Box position:
- 8 EDSFF: Box 3 (single kit);
- 16 EDSFF: Box 3+4
- 24 EDSFF: Box 3+4+6
- 32 EDSFF: Box 1+3+4+6
The Intel® Xeon® 6 series of processors offers up to 4 P-Core processors. You need to install the PEM for the 3rd and 4th Processors
The Intel® Xeon® 6 series processor stack is comprised entirely of performance cores (P-Cores), providing high core counts optimized for power and performance.
- Optimized for multi-threaded applications and workloads
- Up to 86 cores at 350 W TDP
- 6400 MT/s DDR5 memory
- Up to four 24 GT/s UPI 2.0
- PCIe 5.0 with up to 88 lanes per CPU
- Security features (SGX)
Heat Sink- Default Heat Sink
- Processor socket 1 must always be populated, or the server will not function
- Heatsink quantity is automatically configured to match the number of processors ordered
- Contains One Heat Sink per Kit
Direct Liquid Cooling (DLC)- Cannot be mixed with any other (air-cooled) heatsinks in the same server
- Requires a Qty 1 55cm Quick Disconnect Tube Set (P62042-B21)
- Facility water supply temperature must not exceed 40°C (104°F)
Server Fans- Server ships with 4 dual-rotor hot-plug fans by default (8 rotors total) for main system cooling
- Redundant fan mode: if one rotor fails, the system switches to nonredundant mode and keeps running, with the system health LED flashing amber
- If a second rotor fails, or a fan is missing, the operating system performs a graceful shutdown
PCIe Fan Adapters- PCIe fans are only used when a DPU (Data Processing Unit) is installed
- Slot pairing is fixed by configuration:
- 1 DPU in Slot 5 requires a PCIe fan in Slot 6 (2P and 4P);
- 2 DPUs in Slots 3+5 (2P) require PCIe fans in Slots 4+6 (2P)
- 2 DPUs in Slots 5+7 (4P) require PCIe fans in Slots 6+8 (4P)
- install DPU and PCIe fan options
The MR (MegaRAID) and SR (Smart Array) controller families use different management tools and cannot be installed together in the same server. With a tri-mode U.3 backplane, both series support SAS, SATA, and NVMe drives, allowing mixed drive types in one system. This server has no built-in hardware RAID, so a storage controller is required for any RAID functionality — direct-attached SATA drives without one run in AHCI mode only.
SR Series (SmartRAID)SR Series
Installation Service Manual
The SR series on this server is limited to one option: HPE Smart Array E208e-p SR Gen10
Type-p (PCIe plug-in) form factor only
8 external SAS lanes, no cache — used for connecting external SAS storage, not internal drive management
No battery or capacitor required (no cache to protect)
MR Series (MegaRAID) - View PDFMR Series
Installation Service Manual
Available in type-o (OCP) and type-p (PCIe plug-in) form factors
Flash-Backed Write Cache (FBWC), requiring a separate energy pack (battery or hybrid capacitor)
MR932i-p (900 series): PCIe Gen5, up to 32 SAS/NVMe drives, onboard battery included
MR200/400 series supports SAS/SATA HDD and SSD only — no NVMe
Choosing Between MR and SR
- MR932i-p – NVMe/SAS support not stated in manuals
- Need OCP slot → MR216i-o, MR416i-o, or MR408i-o
- No cache needed → MR216i-o/p (not valid for 24SFF x4 or 32SFF x4)
- 8SFF x1 only, cache needed → MR408i-o/p
- Cache + scales up to 32SFF x4 → MR416i-o/p
- Highest lane count (x32 PCIe Gen5) → MR932i-p; drive count not specified
- External SAS → E208e-p (Gen10, external, no cache)
Boot Front Install P79031-B21
- Front (Box 4) – only if Box 4 has no drive cage installed
- Requires Front enablement kit P79031-B21
- Cables connect directly to system board
Boot Rear InstallP80440-B21
- Rear (power supply bay) – used if Box 4 is occupied
- Requires Rear enablement kit P80440-B21
- Requires removing GPU cage to install
- Front and Rear Enable kits cannot be selected together
- Front enablement of NS204i-u Boot device requires Box 4 to be available.
- P78279-B21 - HPE NS204i-u v2 480GB NVMe Hot Plug Boot Optimized Storage Device
OCP A — embedded (soldered directly to the system board), PCIe 5.0, x16 connector width but x8 bus width by default
OCP B — optional/cabled (not embedded — needs a cable back to the riser/system board), same PCIe 5.0, x16 connector, x8 bus by default
- P80427-B21 — OCP Slot A x16 Enablement Kit (Slot 14)
- P80428-B21 — OCP Slot B x16 Enablement Kit (Slot 15)
There are 2 OCP 3.0 slots total, both on the rear panel, no front OCP option on this server.
There is only one riser option. Each riser provides 2x PCIe 5.0 slots (full-height, ¾-length), giving up to 12 total PCIe slots when all six positions are populated.
- 2 Socket Config
- Risers 2,3,4 Available
- Default Wired PCIe lanes Riser 2 & 3
- Riser 4 - Cable P80381-B21 Needed
- 4 Socket Config
- Risers 1,2,3,4,5,6 Available
- Default Wired PCIe lanes Riser 3 & 4
- Riser 2 & Riser 5 - Cable P80381-B21 Needed
- Riser 1 & Riser 6 - Cable P81004-B2 Needed
The mixing of 2 different power supplies is NOT allowed.
- 2 Socket Config
- Min PSU: 1
- Max PSU: 2
- 4 Socket Config
- Min PSU: 2
- Max PSU: 4
If you install the P73210-B21 (2200W -48VDC PSU), you also need to select the P79839-B21 (Power Lug Kit)
Current Configuration
(List below serves as quick links to each section)
Chassis
Processors
Backplans / Drive Cages
Cooling Options
Memory
Boot Options
Storage Controller
Networking
OCP
Host Bus Adapter (HBA)
Drives SFF
Drives NVMe
Drives EDSFF
Riser Options
Optical Disk Drive (ODD)
Rail Kit
Power Supply Units (PSU)
ECS Warranty
The request has been sent.
Thank you.
Price as Configured:
$0
Base Standard Capabilities
| Technical specifications | HPE ProLiant Compute DL580 Gen12 |
|---|---|
| Processor type | Intel |
| Processor family | Intel® Xeon® 6 processors |
| Processor number | 2 to 4 |
| Processor core available | 8 to 86, depending on processor |
| Processor speed | 4.0 GHz maximum, depending on processor |
| Processor cache | Up to 336 MB L3, depending on processor |
| Memory type | HPE DDR5 Smart Memory |
| Maximum memory | 16 TB with 256 GB DDR5 |
| Memory slots | 64 |
| Memory protection features | RAS – Advanced ECC, online spare, mirroring, combined channel (lockstep) functionality, and HPE Fast Fault Tolerant Memory (ADDDC) |
| System fan features | High Performance Hot-plug redundant Fan Kit |
| Expansion slots | Up to 12 PCIe Gen5, and 2 OCP 3.0 (rear), for detailed descriptions reference the QuickSpecs |
| Form factor | 4U Rack |
| Network controller | 1 Gb, 10 Gb, 10/25 Gb, 100 Gb, or 200 Gb, in PCIe adapter or OCP 3.0 form factor, depending on model. For detailed descriptions reference the QuickSpecs. |
| Storage controller | HPE MR216i-o and/or MR216i-p, HPE MR416i-o and/or HPE MR416i-p, HPE MR408e-p, HPE MR408i-o and/or HPE MR408i-p, depending on model. For detailed descriptions reference the QuickSpecs. |
| Drive supported | Up to 32 SFF/EDSFF NVMe drives, depending on configuration |
| Optical drive type | Optional DVD-ROM through Universal Media Bay |
| Power supply type | 1500W, 2400W, or 3200W Dual hot-plug redundant 1+1, 2+2, or 3+1 HPE Flexible Slot Power Supplies |
| Infrastructure management | HPE iLO Standard with intelligent provisioning (embedded), HPE OneView Standard (requires download) (standard), HPE iLO Advanced, HPE OneView Advanced (optional, requires licenses), and HPE Compute Ops Management |
| Security | HPE TPM 2.0 standard on motherboard. Optional locking Bezel Kit, Intrusion Detection Kit. |