Base Standard Capabilities
Feature | Technical Specifications | |
---|---|---|
Processor | One 4th Generation Intel Xeon Scalable processor with up to 32 cores per processor | |
Memory | 8 DDR5 DIMM slots, supports RDIMM 1 TB max, speeds up to 4800 MT/s. Supports registered ECC DDR5 DIMMs only | |
Storage controllers | • Internal Controllers: PERC H965i, PERC H755, PERC H355, HBA355i • Internal Boot: Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 1, 2 x M.2 NVMe SSDs | • External HBA (non-RAID): HBA355e • Software RAID: S160 |
Drive Bays | Front bays: Up to 4 x 2.5-inch SATA, SAS, or NVMe SSDs max 30.72 TB | |
Hot swap redundant Power Supplies | • 1800 W Titanium 200—240 VAC or 240 HVDC • 1400 W Platinum 100—240 VAC or 240 HVDC • 1100 W Titanium 100—240 VAC or 240 HVDC | • 1100 W -48 — (-60) VDC • 800 W Platinum 100—240 VAC or 240 HVD • 800 W -48 — (-60) VDC |
Cooling Options | Air cooling | |
Fans | 6 Standard cold swap fans | |
Dimensions and Weight | Rear Accessed configuration | Front Accessed configuration |
• Height: 42.8 mm (1.68 inches) • Width: 482.6 mm (19 inches) • Depth: 400 mm (15.74 inches) ear to rear wall • Depth: 487.7 mm (19.20 inches) with bezel • Depth: 463 mm (18.22 inches) without bezel • Weight: 11.27 kg (24.84 pounds) | • Height: 42.8 mm (1.68 inches) • Width: 482.6 mm (19 inches) • Depth: 400 mm (15.74 inches) ear to rear wall • Depth: 566.05 mm (22.28 inches) with bezel • Depth: 472.7 mm (18.61 inches) without bezel • Weight: 11.37 kg (25.06 pounds) | |
Form Factor | 1U rack server | |
Embedded Management | iDRAC9, iDRAC Direct, iDRAC RESTful API with Redfish, iDRAC Service Module | |
Bezel | Optional bezel or security bezel with dust filter | |
OpenManage Software | • CloudIQ for PowerEdge plug in • OpenManage Enterprise • OpenManage Enterprise Integration for VMware vCenter • OpenManage Integration for Microsoft System Center | • OpenManage Integration with Windows Admin Center • OpenManage Power Manager plugin • OpenManage Service plugin • OpenManage Update Manager plugin |
Mobility | OpenManage Mobile | |
OpenManage Integrations | • BMC Truesight • Microsoft System Center • OpenManage Integration with ServiceNow | • Red Hat Ansible Modules • Terraform Providers • VMware vCenter and vRealize Operations Manager |
Security | • Cryptographically signed firmware • Data at Rest Encryption (SEDs with local or external key mgmt) • Secure Boot • Secured Component Verification (Hardware integrity check) | • Secure Erase • Silicon Root of Trust • System Lockdown (requires iDRAC9 Enterprise or Datacenter) • TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ |
Embedded NIC | • 4 x 25 GbE SFP+ LOM | |
Network options | • 1 x OCP card 3.0 (optional) | |
Ports | For Rear Accessed configuration | For Front Accessed configuration |
Front Ports • 1 x iDRAC Direct (Micro-AB USB 2.0) port, 1 x USB 2.0 Rear Ports • 1 x iDRAC dedicated port, 1 x USB 3.0, 1 x Serial (Micro- AB USB 2.0) port, 1 x Mini-DisplayPort, 1 x RJ45 for dry contact, 4 x 25 GbE SFP+ LOM | Front Ports • 1 x iDRAC Direct (Micro-AB USB 2.0) port, 1 x iDRAC dedicated port, 1 x USB 3.0, 1 x Serial (Micro-AB USB 2.0) port • 1 x Mini-DisplayPort, 4 x 25 GbE SFP+ LOM, 1 x RJ45 for dry contact Rear Ports • N/A | |
PCIe | 1 CPU configuration: Up to 2 PCIe slots (2 x16 Gen5) | |
GPU | Up to 2 x 75 W GPUs (single-width, full-height, half-length) | |
Operating System and Hypervisors | • Canonical Ubuntu Server LTS • Microsoft Windows Server with Hyper-V • Red Hat Enterprise Linux | • SUSE Linux Enterprise Server • VMware ESXi |
Compare Servers
Features | PowerEdge XR5610 | PowerEdge XR11 | ||
---|---|---|---|---|
Processors | 1x 4th Gen Intel® Xeon® Scalable Processors including Edge Enhanced CPUs with Intel vRAN Boost | 1 x 3rd Generation Intel® Xeon® Processor Scalable Family | ||
CPU interconnect | Intel Ultra Path Interconnect (UPI) | Intel Ultra Path Interconnect (UPI) | ||
Memory | ● 8 x DDR5 RDIMM ● Up to 4800 MT/s | ● 8 x DDR4 RDIMM, LRDIMM ● Two Intel Optane Persistent Memory 200 series configuration: ○ 4+4 ○ 6+1 | ||
Storage Controllers | ● PERC 11G: H755, H355 ● PERC 12G: H965i ● HBA 11: HBA355i, HBA355e ● BOSS-N1 ● Software RAID: S160 | ● PERC 10G: H345 ● PERC 11G: H755, H355 ● HBA 11: HBA355i, HBA355e ● BOSS-S1 adapter ● BOSS-S1 ● Software RAID: S150 | ||
Drive Bays | 4 x 2.5 inches 12 Gb SAS, 6 Gb SATA, NVMe | 4 x 2.5 inches 12 Gb SAS, 6 Gb SATA, NVMe | ||
Power Supplies | ● AC (Platinum): 800 W, 1400 W, 1800 W ● AC (Titanium): 1100 W ● LVDC -48 VDC input: 800 W, 1100 W | ● AC (Platinum): 800 W, 1400 W, ● AC (Titanium): 700 W, 1100 W ● LVDC @-48 VDC Input: 800 W, 1100 W | ||
Chassis Orientation | XR5610 has two chassis options: 1. Rear Accessed Configuration, where power supplies and network cards are in the rear. NOTE: Network, serial, power supplies, USB, Mini DisplayPort, and PCIe slots are accessible in the rear of the platform and the hard drives, power button, Status LED, USB, and Management port are in the front of the system. 2. Front Accessed Configuration, where power supplies and network cards are in the front. NOTE: Power button, network ports, serial, USB, Mini DisplayPort, and PCIe Slots are accessible in the front of the platform and the hard drives and Status LED are in the rear of the system. The location of the control panel changes with the chassis orientation. | XR11 has two chassis options: 1. Rear Accessed Configuration, where power supplies and network cards are in the rear. NOTE: Network, serial, VGA, power supplies and PCIe slots are accessible in the rear of the platform and the hard drives, power button, Status LED, USB, and Management port are in the front of the system. 2. Front Accessed Configuration, where power supplies and network cards are in the front. NOTE: Power button, network ports, serial, VGA, and PCIe Slots are accessible in the front of the platform and the hard drives and Status LED are in the rear of the system. The location of the control panel changes with the chassis orientation. | ||
Fans | Standard fans | Very High Performance fans | ||
Standard fans | Very High Performance fans | |||
Dimension Form Factor | Rear Accessed configuration | Front Accessed configuration | Rear Accessed configuration | Front Accessed configuration |
Height: 42.8 mm (1.68 inches) | Height: 42.8 mm (1.68 inches) | Height: 42.8 mm (1.68 inches) | Height: 42.8 mm (1.68 inches) | |
Width: 482.6 mm (19 inches) | Width: 482.6 mm (19 inches) | Width: 482.6 mm (19 inches) | Width: 482.6 mm (19 inches) | |
Depth: 487.7 mm (19.2 inches) with bezel | Depth: 566.05 mm (22.28 inches) with bezel | Depth: 477 mm (18.77 inches) with bezel | Depth: 400 mm (15.74 inches) ear to rear wall | |
463 mm (18.22 inches) without bezel | 472.7 mm (18.61 inches) without bezel | 463 mm (18.22 inches) without bezel | 463 mm (18.22 inches) without bezel | |
1U rack server | 1U rack server | |||
Embedded Management | ● iDRAC9 ● iDRAC Direct ● iDRAC RESTful API with Redfish ● iDRAC Service Module | ● iDRAC9 ● iDRAC Direct ● iDRAC RESTful API with Redfish ● iDRAC Service Module | ||
Bezel | Optional LCD bezel or security bezel | Optional LCD bezel or security bezel | ||
OpenManage Software | ● CloudIQ for PowerEdge plug in ● OpenManage Enterprise ● OpenManage Enterprise Integration for VMware vCenter ● OpenManage Integration for Microsoft System Center ● OpenManage Integration with Windows Admin Center ● OpenManage Power Manager plug-in ● OpenManage Service plug-in ● OpenManage Update Manager plug-in | ● CloudIQ for PowerEdge plug in ● OpenManage Enterprise ● OpenManage Enterprise Integration for VMware vCenter ● OpenManage Integration for Microsoft System Center ● OpenManage Integration with Windows Admin Center ● OpenManage Power Manager plug-in ● OpenManage Service plug-in ● OpenManage Update Manager plug-in ● OpenManage SupportAssist plug-in | ||
Mobility | OpenManage Mobile | OpenManage Mobile | ||
Integrations and Connections | OpenManage Integrations ● BMC TrueSight ● Microsoft System Center ● OpenManage Integration with ServiceNow ● Red Hat Ansible Modules ● Terraform Providers ● VMware vCenter and vRealize Operations Manager | OpenManage Integrations ● Microsoft System Center ● OpenManage Integration with ServiceNow ● Red Hat Ansible Modules ● VMware vCenter ● Third-party Connectors (Naglos, Tivoli, Microfocus) | ||
Security | ● Cryptographically signed firmware ● Data at Rest Encryption (SEDs with local or external key management) ● Secure Boot ● Secured Component Verification (Hardware integrity check) ● Secure Erase ● Silicon Root of Trust ● System Lockdown (requires iDRAC9 Enterprise or Datacenter) ● TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ | ● Cryptographically signed firmware ● Secure Boot ● Secured Component Verification (Hardware integrity check) ● Secure Enterprise Key Management ● Silicon Root of Trust ● System Lockdown (requires iDRAC9 Enterprise or Datacenter) ● TPM 1.2/2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ | ||
Embedded NIC | 4 x 25 GbE LOM | 4 x 25 GbE LOM | ||
Networking Options | OCP 3.0 Mezz 3.0 (optional) | Not supported | ||
GPU Options | Up to 2 x 75 W/150 W (SW/FH/HL) | Up to 2 x 70 W (SW/FH/HL) | ||
Ports | Rear Accessed Configuration ● Front: ○ 1 x iDRAC Direct (Micro-AB USB 2.0) port ○ 1 x USB 2.0 ● Rear: ○ 1 x USB 3.0 ○ 1 x iDRAC dedicated port ○ 1 x Serial port (Micro-AB USB 2.0-compliant) ○ 1 x Mini-DisplayPort ○ 1 x RJ45 for dry contact ○ 4 x 25 GbE SFP+ LOM | Rear Accessed Configuration ● Front: ○ one standard USB 2.0 port ○ one micro USB 2.0 port dedicated to iDRAC management ● Rear: ○ one standard USB 3.0 port ○ one standard USB 2.0 port ○ one Dedicated 1 GbE ○ one Serial port ○ one VGA port ● Internal: one standard USB 3.0 port on Riser 1 B | ||
Front Accessed Configuration ● Front: ○ 1 x iDRAC Direct (Micro-AB USB 2.0) port ○ 1 x iDRAC dedicated port ○ 1 x USB 3.0 ○ 1 x Serial (Micro-AB USB 2.0-compliant) ○ 1 x Mini-DisplayPort ○ 4 x 25 GbE SFP+ LOM ○ 1 x RJ45 for dry contact ● Rear: N/A | Front Accessed Configuration ● Front: ○ one standard USB 3.0 port, one standard USB 2.0 port, one micro USB 2.0 port that is dedicated to iDRAC management, one Dedicated 1 GbE, one Serial port, one VGA port ● Rear: N/A ● Internal: one standard USB 3.0 port on Riser 1 B | |||
PCIe | One riser configuration: ● Up to 2 x PCIe Gen5 (two x16 PCIe Gen5) | Two riser configuration options: ● 3 x PCIe Gen4 (one x8 PCIe Gen4 + two x16 PCIe Gen4) ● 3 x PCIe Gen4 (one x16 PCIe Gen4 + two x16 PCIe Gen4) (Only supported for Front Accessed Chassis) | ||
Operating System and Hypervisors | ● Canonical Ubuntu Server LTS ● Microsoft Windows Server with Hyper-V ● Red Hat Enterprise Linux ● SUSE Linux Enterprise Server ● VMware ESXi | ● Canonical Ubuntu Server LTS ● Citrix Hypervisor ● Windows Server LTSC with Hyper-V ● Red Hat Enterprise Linux ● SUSE Linux Enterprise Server ● VMware ESXi ● RHEL Realtime |