Quick Specs
ModelsDrive Types
12 Gb/s SAS
6 Gb/s SAS/SATA
PCI-e 3.0
SAS Connectors2x4 External
Cache Memory8 GB NV
Write Back CacheFlash Backed Cache
RAID Levels0,1,5,6,10,50,60
Max Drive Support32
RAID SupportHardware
Part Numbers:
- 2NJ9P
- 4R84R
- 0878M
- 5FMY4
- GP6RN
The PERC H740P RAID Controller from Dell offers reliability and performance in addition to providing management with the tolerant disk subsystem failures. This RAID controller improves the performance of your server systems. The double module channel provides high-speed connectivity. This product has been tested and validated on Dell systems to ensure compatibility with your computer. It is supported by Dell Technical Support when used with a Dell system.
H740P PERC Series Options
H740P Adapter
View PERC
Enclosures per port
0
Cache:8 GB DDR4 2133MT/s
RAID Level:0, 1, 5, 6, 10, 50, 60
Non-RAID:Yes
PCIe:Gen 3
Supported Drives:- 6 Gbps SATA/SAS
- 12 Gbps SAS
- 8 drives per controller
- w/ SAS Expander: Limited by platform offerings
- Not Supported
- 32 SAS/SATA
Front H740P Mini Mono
View PERC
Enclosures per port
0
Cache:8 GB DDR4 2133MT/s
RAID Level:0, 1, 5, 6, 10, 50, 60
Non-RAID:Yes
PCIe:Gen 3
Supported Drives:- 6 Gbps SATA/SAS
- 12 Gbps SAS
- 8 drives per controller
- w/ SAS Expander: Limited by platform offerings
- Not Supported
- 32 SAS/SATA
Summary of RAID levels
Summary of RAID levels Following is a list of the RAID levels supported by the PERC 12 series of cards:
- RAID 0 Uses disk striping to provide high data throughput, especially for large files in an environment that requires no data redundancy.
- RAID 1 Uses disk mirroring so that data written to one physical disk is simultaneously written to another physical disk. RAID 1 is good for small databases or other applications that require small capacity and complete data redundancy.
- RAID 5 Uses disk striping and parity data across all physical disks (distributed parity) to provide high data throughput and data redundancy, especially for small random access.
- RAID 6 Is an extension of RAID 5 and uses an additional parity block. RAID 6 uses block-level striping with two parity blocks distributed across all member disks. RAID 6 provides protection against double disk failures, and failures while a single disk is rebuilding. If you are using only one array, deploying RAID 6 is more effective than deploying a hot spare disk.
- RAID 10 Is a combination of RAID 0 and RAID 1, uses disk striping across mirrored disks. It provides high data throughput and complete data redundancy.
- RAID 50 Is a combination of RAID 0 and RAID 5 where a RAID 0 array is striped across RAID 5 elements. RAID 50 requires at least six disks.
- RAID 60 Is a combination of RAID 0 and RAID 6 where a RAID 0 array is striped across RAID 6 elements. RAID 60 requires at least eight disks.
Compatible With:
- Dell R640
- Dell R6415
- Dell R6515
- Dell R740
- Dell R740xd
- Dell R7415
- Dell R7515
(Click to View)
Spec Sheet 4
| Models | Drive Types | PCI Support | SAS Connectors | Cache Memory | Write Back Cache | RAID Levels | Max Drive Support | RAID Support |
|---|---|---|---|---|---|---|---|---|
| H840 Adapter FH | 12 Gb/s SAS 6 Gb/s SATA |
PCIe 3.1 | 2x4 External | 8 GB NV | Flash Backed Cache | 0,1,5,6,10,50,60 | 255 | Hardware |
| H840 Adapter LP | ||||||||
| H745P MX Adapter | 12 Gb/s SAS 6 Gb/s SATA/SAS 3 Gb/s SATA |
PCIe 3 | Modular Enclosure | 8 GB NV | Flash Backed Cache | 0,1,5,6,10,50,60 | - | Hardware |
| H740P FH | 12 Gb/s SAS 6 Gb/s SATA |
PCIe 3.1 | 2x4 External | 8 GB NV | Flash Backed Cache | 0,1,5,6,10,50,60 | 32 | Hardware |
| H740P LP | ||||||||
| H740P Mini Mono | 12 Gb/s SAS 6 Gb/s SATA |
PCIe 3.1 | 2x4 External | 8 GB NV | Flash Backed Cache | 0,1,5,6,10,50,60 | 32 | Hardware |
| S150 Software RAID | 6 Gb/s SATA/NVMe | PCIe | N/A | No Cache | No Cache | 0,1,5,10 | 30* | Software RAID Windows and Linux |
| S140 Software RAID | 6 Gb/s SATA/NVMe | N/A | N/A | No Cache | No Cache | 0,1,5,10 | 16* | Software RAID Windows and Linux |
| 12 Gbps SAS Ext. HBA | 12 Gb/s SAS | PCIe 3.0 | 2x4 External | No Cache | No Cache | No RAID Pass-Thru Only | 255 | No RAID Pass-Thru Only |
| H745 Adapter | 12 Gb/s SAS 6 Gb/s SATA/SAS 3 Gb/s SATA |
PCIe 3 | 2x8 Internal | 4 GB NV | Flash Backed Cache | 0,1,5,6,10,50,60 | 240 | Hardware |
| H745 Front | 12 Gb/s SAS 6 Gb/s SATA/SAS 3 Gb/s SATA |
PCIe 3 | 2x8 Internal | 4 GB NV | Flash Backed Cache | 0,1,5,6,10,50,60 | 240 | Hardware |
| H345 FH | 12 Gb/s SAS 6 Gb/s SATA/SAS 3 Gb/s SATA |
PCIe 3 | 2x8 Internal | No Cache | No Cache | 0,1,10 | 63 | Hardware |
| H345 LP | ||||||||
| H345 Front | 12 Gb/s SAS 6 Gb/s SATA/SAS 3 Gb/s SATA |
PCIe 3 | 2x8 Internal | No Cache | No Cache | 0,1,10 | 63 | Hardware |
| *The S150 controller supports up to 8 SATA disks (HDD and SSD) depending on system backplane configuration, supports up to 30 NVMe PCIe SSDs. | ||||||||
| *The S140 controller supports up to 16 physical disks (SATA + NVMe) depending on system backplane configuration except the PowerEdge R840 and PowerEdge R940xa supports up to 30 (SATA + NVMe). | ||||||||