Quick Specs
What's New for ML110 Gen10
  • (1) Intel® Xeon® 1st or 2nd Gen Scalable processors up to 16C
  • (6) DDR4 DIMM slots
  • Max Memory 192GB
  • (16) SFF hot-plug drives
  • (5) PCIe 3.0 slots
  • HPE Smart Array S100i SR Gen10 SW RAID (10 SATA)
  • Embedded 2-port 1GbE (Broadcom 5720-based)
  • HPE iLO 5 ASIC
  • GPU Supported

Ideal for:
  • Cloud Servers
  • Corporate IT
  • Data Analytics
  • Database
  • Edge Servers
  • Retail Servers
  • Virtual Desktop Interface (VDI)
  • Virtualization
  • Web Tech

The HPE ProLiant ML110 Gen10 server offers enterprise-class performance, reliability, and scalability in a compact 4.5U tower design. Powered by Intel® Xeon® Scalable processors and supporting up to 192GB of HPE DDR4 SmartMemory, this server delivers exceptional compute power for growing SMBs, branch offices, and remote deployments.


With flexible storage options supporting up to 8 LFF or 16 SFF drives, 5 PCIe expansion slots, and enhanced security features like Silicon Root of Trust, it ensures efficiency and peace of mind. Upgradeable cooling and power supply options further enhance its versatility for demanding workloads.

Looking to Customize?

Configure your ML110 — drives, RAID, rails, and warranty.
Talk to a sales expert today.

Build Your Refurbished ML110 →

Specs 1

Physical specifications

Specifications
Description
Dimensions (H x W x D)
44 x 19.5 x 48.05 cm (17.32 x 7.68 x 18.92 in)
Weight (Approximate)
Minimum: 13.5 kg (29.82 lb)
Maximum: 25.0 kg (55.0 lb)

top

Electrical specifications

Specifications
Description
Input requirements (Per power supply)
Rated line voltage
100 to 120 V ac
Rated input frequency
  • For 350 W and 550 W power supply: 8 A (At 100~240 V ac)

  • 50 to 60 Hz

Rated input power
  • For 550 W power supply: < 639 W (At 100 V ac), < 605 W (At 200 V ac)

  • For 350 W power supply: < 427 W (At 100 V ac), < 427 W (At 200 V ac)

BTU rating
  • For 550 W power supply: 2204 BTU/hr (At 100 V ac), 2113 BTU/hr (At 200 V ac)

  • For 350 W power supply: 1452 BTU/hr (At 100 V ac), 1544 BTU/hr (At 200 V ac)

Power supply output (Per power supply)
Rated Steady-State power
For 550 W power supply: 550 W (At 100 V ac), 550 W (At 200 V ac)
Maximum peak power
For 350 W power supply: 350 W (At 100 V ac), 350 W (At 200 V ac)

top

Environmental specifications

Specifications
Description
System inlet temperature
Standard operating temperature
  • 10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight

  • Maximum rate of change is 20°C/hr (36°F/hr)

  • The upper limit and rate of change may be limited by the type and number of options installed

  • System performance during standard operating support may be reduced if operating with a fan fault or above 30°C (86°F)

Extended ambient operating support
5° to 10°C (41° to 50°F) and 35° to 40°C (95° to 104°F) at sea level with an altitude derating of 1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3048 m (10,000 ft)
Non-Operating temperature
  • -30° to 60°C (-22° to 140°F)

  • Maximum rate of change is 20°C/hr (36°F/hr)

Relative humidity (Rh)
Operating
8% to 90% - Rh, 28°C maximum wet bulb temperature, Non-Condensing
Non-operating
5% to 95% - Rh, 38.7°C (101.7°F) maximum wet bulb temperature, Non-Condensing
Altitude
Operating
  • 3050 m (10,000 ft)

  • Maximum allowable altitude change rate is 457 m/min (1500 ft/min)

Non-operating
  • 9144 m (30,000 ft)

  • Maximum allowable altitude change rate is 457 m/min (1500 ft/min)

Acoustic noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). The listed sound levels apply to standard shipping configurations. Additional options may result in increased sound levels. HPE representative provide information from the HPE EMESC website for further technical details regarding the configurations listed below.
Idle
LWAd
  • 4.0 Bels Entry

  • 4.0 Bels Perf

LpAm
  • 24.8 dBA Entry

  • 24.1 dBA Perf

Operating
LWAd
  • 4.0 Bels Entry

  • 4.0 Bels Perf

LpAm
  • 25.1 dBA Entry

  • 24.1 dBA Perf

top