-PLEASE CONTACT FOR CUSTOM CONFIGURATIONS. DISK SHELVES, COMPLETE CONFIGURATIONS & TURN KEY SYSTEMS AVAILABLE.
-SPARE PARTS AVAILABLE FOR EACH MODEL. PLEASE ASK FOR PRICING ON SPARE DISK, CONTROLLERS, POWER SUPPLIES, NICs, HBAs, SFPs, Cables, etc.
- Intel Xeon E5-2400 v2 Series Processors
- New HPE Common Slot Power Supplies providing 96% server power efficiency
- New low voltage DIMMs running at 1600 MHz to reduce energy bills
The HP ProLiant DL380e Gen8 sets the next generation standards of 2U 2-socket rack servers for the industry. With enhanced configuration flexibility, unmatched performance, and leading energy efficient design the DL380e Gen8 offers the perfect solution for the dynamic compute and storage requirements of today's demanding datacenters.
The refurbished HP ProLiant DL380e Gen8 Server Compute and storage, ideal for essential data center needs. The HP ProLiant DL380e Gen8 offers unprecedented configuration flexibility to suit a wide range of infrastructure sizes and compute. With enterprise-class uptime, enhanced storage performance, serviceability, and management capabilities, this dual-socket, 2U rack server is a perfect match for those looking for great value and essential features with the flexibility to boost configurations in the future.
- Cloud Servers
- Corporate IT
- Database
Configure your DL380 — drives, RAID, rails, and warranty.
Talk to a sales expert today.
Build Your Refurbished DL380 →
Specs 1
Software overview
Feature | Description |
|---|---|
Operating System (OS) and virtualization software support for ProLiant servers 1 |
|
Physical specifications
Feature | Description |
|---|---|
Dimensions - with bezel (H x W x D) |
|
Weight (approximate) |
|
Electrical specifications
Feature | Description |
|---|---|
Input requirements | |
Rated line voltage |
|
Rated input current |
|
Rated input frequency | 50 to 60 Hz |
Rated input power |
|
BTU rating (maximum) |
|
Power supply output (per power supply) | |
Rated steady-state power |
|
Maximum peak power |
|
Environmental specifications
Feature | Description | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
System inlet temperature (operating) | 10° to 35°C (50° to 95°F), at sea level with an altitude derating of 1.0°C per every 304.8 m (1.8°F per every 1000 ft) above sea level to a maximum of 3048 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). | ||||||||||||||||||||||||
System inlet temperature (non-operating) | -30° to +60°C (-22° to +140°F). Maximum rate of change is 20°C/hr (36°F/hr). | ||||||||||||||||||||||||
Relative humidity (operating) | 10% to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing | ||||||||||||||||||||||||
Relative humidity (non-operating) | 5% to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing | ||||||||||||||||||||||||
Altitude (operating) | 3048 m (10,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min) | ||||||||||||||||||||||||
Altitude (non-operating) | 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min) | ||||||||||||||||||||||||
Acoustic noise 1 | Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
| ||||||||||||||||||||||||
1. The Listed sound levels apply to standard shipping configurations. Additional options may result in increased sound levels. | |||||||||||||||||||||||||