SKU: 652063-B21

Hpe Proliant Ml350P Gen8 8Sff Rack Server | 652063-B21

Condition: Refurbished ✓ Pulled from working servers & Tested. ✓ 1-year Parts Warranty.

Warranty | Return Policy

-PLEASE CONTACT FOR CUSTOM CONFIGURATIONS. DISK SHELVES, COMPLETE CONFIGURATIONS & TURN KEY SYSTEMS AVAILABLE.

-SPARE PARTS AVAILABLE FOR EACH MODEL. PLEASE ASK FOR PRICING ON SPARE DISK, CONTROLLERS, POWER SUPPLIES, NICs, HBAs, SFPs, Cables, etc.

Quick Specs
What's New for ML350p Gen8
  • Increased performance of up to 35% at the same or lower power levels with the new Intel® Xeon® E5-2600 v2 processors
  • HP SmartMemory for 16.6% better memory performance. HP SmartMemory at 1866MHz @2 DPC vs. 1600MHz @2 DPC
  • GPU support to boost performance in graphic and VDI applications for financial services, education, scientific research, and medical imaging
  • Latest HP Smart Array Controllers designed to maximize data availability, performance and capacity
  • Up to 4x workload performance with HP SmartCache, a controller-based caching solution that caches hot data onto lower latency SSDs.

The refurbished HPE ProLiant ML350p Gen8 Server series is the latest generation of the best-selling ProLiant ML servers delivering best-in-class performance, availability and maximum expandability for enterprise data centers, remote branch offices and growing businesses. Incorporating key HP technologies from the HP ProActive Insight architecture, the ML350p Gen8 provides innovations in memory, server management, firmware management and server storage. It combines these innovations with the latest Intel Xeon processors for a system with unsurpassed flexibility and performance.


Ideal for:
  • Cloud Servers
  • Corporate IT
  • Database
Looking to Customize?

Configure your ML350 — drives, RAID, rails, and warranty.
Talk to a sales expert today.

Build Your Refurbished ML350 →

Specs 1

Physical specifications

Feature
Description
Dimensions (H x W x D) (with feet/bezel)
  • Tower: 46.2 x 21.8 x 74.0 cm (18.19 x 8.58 x 29.13 in)

  • Rack: 21.8 x 48.26 x 73.22 cm (8.58 x 19.0 x 28.83 in)

Weight (approximate)
  • Tower:

    • Maximum (all hard drives, power supplies, and processors installed): 52.09 kg (114.84 lb)

    • Minimum (one hard drive, power supply, and processor installed): 31.9 kg (70.33 lb)

  • Rack:

    • Maximum (all hard drives, power supplies, and processors installed): 50.06 kg (110.36 lb)

    • Minimum (one hard drive, power supply, and processor installed): 27.63 kg (60.91 lb)

Electrical specifications

Feature
Description
Rated line voltage
100 to 240 V ac
Rated input current
7.1 A (at 120 V ac) to 3.5 A (at 240 V ac)
Rated input frequency
50 to 60 Hz
Rated input power
852 W
BTU rating (maximum)
  • 460 W: 1773 BTU/hr (at 120 V ac), 1715 (at 240 V ac)

  • 750 W: 2892 BTU/hr (at 120 V ac), 2797 (at 240 V ac)

  • 1200 W: 3530 BTU/hr (at 120 V ac), 4600 (at 240 V ac)

Rated steady-state power
  • 460 (750) W (at 100 V ac)

  • 460 (750) W (at 200 V ac)

Maximum peak power
  • 460 (750) W (at 100 V ac)

  • 460 (750) W (at 200 V ac)

Environmental specifications

Feature
Description
System inlet temperature (operating)
10° to 35°C (50° to 95°F), at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed.
System performance may be reduced if operating with a fan fault or above 30°C (86°F).
System inlet temperature (non-operating)
-30° to +60°C (-22° to +140°F). Maximum rate of change is 20°C/hr (36°F/hr).
Relative humidity (operating)
10% to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing
Relative humidity (non-operating)
5% to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing
Altitude (operating)
3048 m (10,000 ft)
Altitude (non-operating)
9144 m (30,000 ft)
Acoustic noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
  • Idle:

    • LWAd - 1P Non-Redundant - 3.9 B

    • LWAd - 2P Redundant - 4.2 B

    • LpAm - 1P Non-Redundant - 22 dBA

    • LpAm - 2P Redundant - 24 dBA

  • Operating:

    • LWAd - 1P Non-Redundant - 4.0 B

    • LWAd - 2P Redundant - 4.8 B

    • LpAm - 1P Non-Redundant - 22 dBA

    • LpAm - 2P Redundant - 30 dBA