Please remove $0 item(s) from cart - or - Request for Quote

NetApp FAS8200 2-Node Stretch MetroCluster, Fiber Bridge Filer Head (FAS8200-2NBSMC)

 
Price: Request a Quote

Brand:  
MPN:  
FAS8200-2NBSMC
Type:  
Filer Head
Condition:  
ECS Refurbished & Tested

Request Quote

Note: Please include as much details and relevant options about the item to help us match your request with an accurate price.


-PLEASE CONTACT FOR CUSTOM CONFIGURATIONS. DISK SHELVES, COMPLETE CONFIGURATIONS & TURN KEY SYSTEMS AVAILABLE.
-SPARE PARTS AVAILABLE FOR EACH MODEL. PLEASE ASK FOR PRICING ON SPARE DISK, CONTROLLERS, POWER SUPPLIES, NICs, HBAs, SFPs, Cables, etc.

NetApp FAS8200 2-Node Stretch MetroCluster, Fiber Bridge Filer Head (FAS8200-2NBSMC)

Powered by NetApp® ONTAP® data management software, we can help you build a storage infrastructure that is simple, secure, and trusted. NetApp FAS Storage Arrays provides customers with a balance of performance and capacity.


Flexibly adapt to evolving business needs
The demands of a data-driven business require a new approach to storage with an integrated combination of high-performance hardware and adaptive, scalable storage software. The approach needs to support existing workloads as well as adapt and scale quickly to address new applications and evolving IT models.

FAS8200 hybrid storage systems are engineered specifically to address these needs. Powered by NetApp ONTAP data management software, the FAS8200 unifies your SAN and NAS storage infrastructure. When FAS8200 systems are clustered with NetApp AFF all-flash arrays and integrated with the cloud, you have the control to easily move your data to where it’s needed for your business and place it in the storage environment that delivers the best combination of flash performance, storage capacity, and cost efficiency. With proven agility and data management capabilities, the FAS8200 has the flexibility to keep up with changing business needs while delivering on core IT requirements.Provision storage in minutes.
Go from initial power-on to serving data in less than 10 minutes with provisioning for key business applications.

Simplify ongoing management.
Upgrade software or service storage during regular business hours with zero downtime.

Streamline operations.
Leverage one unified system for SAN and NAS with proven storage efficiency.

Secure and protect your data across your hybrid cloud
On-premise & public clouds, we have you covered
Start small and scale nondisruptively as your data requirements grow, on premises and in the cloud.

The Best Cloud Integration
Connect effortlessly to the cloud with leading integration to Amazon AWS, Microsoft Azure, Google Cloud, and others.

Prevent problems before they affect your business
Optimize your storage environment and reduce costs with the predictive analytics and proactive care of NetApp ® Active IQ® .

Customer proven for diverse workloads
Secure your sensitive information
Protect your data at rest and in transit with our portfolio of security capabilities.

Safeguard against data loss
Efficiently replicate data and accelerate recovery with application-consistent data protection.

Eliminate business disruptions
Maintain access to data at all times during service, failures, and site disasters.

Customer proven, real-world results
IDC Whitepaper validates NetApp customers achieve six-nines availability.

Product Specs

Storage Limits

Max # of Drives (Total) Max # of Internal Drives Max # of MSATA Drives Max # of NL-SAS Drives Max # of SAS Drives Max # of SATA Drives Max # of SSD Drives Max # of DS212C Shelves Max # of DS2246 Shelves Max # of DS224C Shelves Max # of DS4243 Shelves Max # of DS4246 Shelves Max # of DS4486 Shelves Max # of DS460C Shelves
Supported Shelves/Drives 480 N/A N/A 480 480 480 480 40 external 20 external 20 external 20 external 20 external N/A

Capacity Limits

Marketing Max Raw Capacity - Node HA Pair Cluster Effective Capacity - Node HA Pair Cluster
N/A N/A 7680000 N/A N/A 34087680

Core Cluster Limits

Max SVM's Max LIF's - NAS Max Connections - NAS Max Flexible Volumes - NAS Max Lock Manager Locked Objects Max Intercluster LIFs - Node Min Root Aggregate (MiB) - Node Min Root Volume (GiB) - Node Max IPsec Policies Max Auditing-Enabled SVMs - Cluster
Node:64
HA Pair:64
Cluster:64
Node:256
HA Pair:256
Cluster:N/A
Node:2500
HA Pair(Non-Scalable):5000
Aggregate (Single data Agg. per Node):Detailed Matrix
Aggregate (Multiple data Agg. per Node):250
Node:200
HA Pair:500
Cluster:1000
Node:700000
HA Pair:700000
Cluster:N/A
8 441245.29 350 SVM:N/A
Cluster:N/A
25

System Maximums and Limits

Max Nodes per Cluster (NAS / SAN) Max FabricPool Size Max Infinite Volume Data Constituent Size Max FlexGroup Data Constituent Size Min Root Volume Size NetApp Volume Encryption
44562 8400 TiB Not Supported Not Supported 350 GiB Supported

Processor

Processor Model Processor Architecture Processor Speed Processor Count (Per Node) Processor Count (Per Config) Processor Cores (Per CPU) Processor Cores (Per Node) Processor Cores (Per Config)
64-bit 16-core 1.70 Ghz 64 bit 1.70 Ghz 1 2 16 16 32

Memory

NVME (Per Node) NVME (Per Config) NVMEM (Per Node) NVMEM (Per Config) RAM (Per Node) RAM (Per Config)
2048 GB 4096 GB 8 GB 16 GB 128 GB 256 GB

Onboard Ports

Ethernet Ports Fibre Channel Ports UTA2 Ports Expansion Slots SAS Ports
2 x RJ45 (10Gb) / 2 x SFP+ (10Gb) - 4 x SFP+ (10Gb/16Gb)  [1] 2 x PCIe3 4 x MiniSAS HD (12Gb)

Physical Characteristics

Rack Units Chassis Height Chassis Width with Mounting Flanges Chassis Width without Mounting Flanges Chassis Depth with Cable Mgmt Chassis Depth without Cable Mgmt Chassis Weight
6 5.12" (13 cm) 18.98" (48.2 cm) 17.6" (44.7 cm) 28.94" (73.5 cm) 23.94" (60.8 cm) See Weights by configuration

System Clearance Dimensions

Front Clearance (Cooling) Front Clearance (Maintenance) Rear Clearance (Cooling) Rear Clearance (Maintenance)
5.91" (15 cm) 29.94" (76 cm) 5.91" (15 cm) 20.09" (51 cm)

Environmental Requirements

Operating Storage Transit Acoustic Noise Input Power Voltage
Tempature:
41 to 113 deg F - 5 to 45 deg C

Humidity:
8 to 90 %

Altitude:
Up to 10000.0 ft - Up to 3048.0 m
Tempature:
-40 to 158 deg F - -40 to 70 deg C

Humidity:
10 to 95 %

Altitude:
Up to 40000.0 ft - Up to 12192.0 m
Tempature:
-40 to 158 deg F - -40 to 70 deg C

Humidity:
10 to 95 %

Altitude:
Up to 39989.8 ft - Up to 12192 m
Sound Power:
6.9 bels

Sound Pressure:
53.1 dBA
100 to 120 200 to 240

Storage OS Requirements

Full OS Matrix Recommended Version Minimum OS Maximum OS
View Full OS Report Below 9.11.1 9.11.1RC1 9.11.1

Storage and Firmware

Full Firmware Matrix BIOS BMC
Full Firmware Report Below 11.15* -

Product Standards Compliance

Full Compliance and Certificates Report Cert. EMC/EMI Cert. Safety Cert. Safety/EMC/EMI Cert. Safety/EMC/EMI/RoHS Standard Safety/EMC/EMI Standard Safety
Compliance and Certificates Report Below AMCA, FCC, ICES, KC, Morocco, VCCI BIS, CB, CSA, G_K_U-SoR, IRAM, NOM, NRCS, SONCAP, TBS EAC, UKRSEPRO BSMI, CE DoC, UKCA DoC BS-EN-55024, BS-EN55035, CISPR 32, EN55022, EN55024, EN55032, EN55035, EN61000-3-2, EN61000-3-3, FCC Part 15 Class A, IC  more... ANSI/UL60950-1, ANSI/UL62368-1, BS-EN62368-1, CAN/CSA C22.2 No. 60950-1, CAN/CSA C22.2 No. 62368-1, CNS 14336, EN60825-1  more...

NFS Cluster Limits

Max Export Policies - Cluster Max Export Rules - Cluster Max NFSv4 Access Control Entries Max Client Objects Max pNFS objects
6000 70000 1024 Node:102400
HA Pair:102400
Node:1024000
HA Pair:1024000
Cluster:N/A

WAFL Cluster Limits - All Maximums

Size 64-bit Aggregate (TiB) Size 64-bit Volume (TiB) File size 64-bit Volume (TiB) Volume Snapshot Copies Character length for Snapshot copy names Hard links - File inodes/files - Volume Number of qtrees Concurrent DataMotion for Volumes ops
800 4/9/1900 16 Volume:255
Node:63750
HA Pair:127500
255 100000 2000000000 Volume:4995
Node:15000
HA Pair:30000
Cluster:N/A
Node:8
HA Pair:16

Quality of Service Cluster Limits

Max Policy Groups - Cluster Max QoS User Workloads - Cluster
6000 20000

SAN Cluster Limits - All Maximums

# of storage virtual machines (SVMs) - SAN # of flexible volumes - SAN # of Flexible Vol with DPO - # of LUNs LUN mappings LUN size (TiB) - LUN FC queue depth available # of SAN Hosts (ITNs) # of LIFS - iSCSI # of LIFS - FCP # of igroups # of Initiators # of Portsets # of iSCSI sessions
Node:64
HA Pair:64
Cluster:64
Single data Aggregate:250
Multiple data Aggregates:200
Node:500
HA Pair:1000
Cluster:N/A
Node:N/A
HA Pair:N/A
Cluster:N/A
Valume:1024
Node:6144
HA Pair:12288
Cluster:N/A
Node:6144
HA Pair:12288
Cluster:N/A
16 2048 Port:256
Node:4096
HA Pair:8192
Cluster:N/A
Port:16
Portset:32
Node:128
HA Pair:256
Cluster:N/A
Port:16
Portset:32
Node:128
HA Pair:256
Cluster:N/A
Node:2048
HA Pair:4096
Cluster:N/A
igroup:256
Node:2048
HA Pair:4096
Cluster:N/A
Node:2048
HA Pair:4096
Cluster:N/A
Node:4096
HA Pair:8192
Cluster:N/A

CIFS Cluster Limits - All Maximums

# of Connected Shares # of Regular Shares # of Open files # of Local users - Cluster # of Local groups - Cluster # of Local group members - Cluster
Node:500000
HA Pair:500000
Node:150000
HA Pair:150000
Cluster:N/A
Connection:32768
Node:350000
HA Pair:350000
17500 160000 320000

Data Protection Cluster Limits - All Maximums

NDMP Sessions Data Protection Mirrors Load Sharing Mirrors - NAS SVM Concurrent Snap Mirror / SnapVault transfers - Node DP Mirror fan-out - Volume LS Mirror fan-out - NAS SVM # of Clusters that can be peered - Cluster Volumes, SnapMirror relationship SnapMirror Synchronous relationships Flexible Volumes in SVM DR SVM Disaster recovery - Cluster
Node:36
HA Pair (Non-Scalable):36
Volume:1
Node:500
HA Pair:1000
Cluster:N/A
2 100 8 2 8 FlexGroup:N/A
FlexGroup-Node:N/A
HA Pair:N/A
Cluster:N/A
Volume:N/A
Node:N/A
HA Pair (Non-Scalable):N/A
SVM:300
HA Pair:1000
128

NVMe/oF Cluster Limits - All Maximums

# of Storage virtual machines (SVMs), NVMe/oF - Cluster # of Flexible volumes, NVMe/oF # of Flexible volumes with DPO, NVMe/oF # of Namespaces # of Subsystems # of Namespace Mappings Namespace Size I/O queue depth available - NVMe/FC - Queue I/O queue count available - NVMe/FC - Controller Hosts - Subsystem LIFS, NVMe/oF # of Controllers - NVMe/FC - Port I/O Queue Count, NVMe/TCP - Controller I/O Queue Depth - NVMe/TCP Controllers, NVMe/TCP - Node
N/A Node:N/A
HA Pair:N/A
Cluster:N/A
Node:N/A
HA Pair:N/A
Cluster:N/A
Volume:N/A
Node:N/A
HA Pair:N/A
Cluster:N/A
Node:N/A
Node:N/A
Subsystem:N/A
Node:N/A
HA Pair:N/A
Cluster:N/A
N/A N/A N/A N/A



N/A N/A N/A N/A

FlexCache Cluster Limits - All Maximums Cache

Degree of fan-out - Origin Origin Volumes Constituent Volumes Volumes Origin ConstituentVolumes
N/A Node:N/A
HA Pair:N/A
Node:N/A
HA Pair:N/A
Node:N/A
HA Pair:N/A
Node:N/A
HA Pair:N/A

S3 Cluster Limits -

Max # of Buckets Max # of Objects - Bucket Max # of Users Max Size of the Bucket (PB) - Vserver
Vserver:N/A
Cluster:N/A
N/A Vserver:N/A
Cluster:N/A
N/A

Consistency Groups - All Maximums

Number of Consistency Groups - Cluster Consistency Groups and Parents Consistency Groups - Cluster Number of Parent Consistency Groups - Cluster Child Consistency Groups in a Parent Consistency Groups - Parent Group Flexible Volumes in a Consistency Group Flexible Volumes for Child Consistency Groups under a Parent Group Flexible Volumes in a Child Consistency Group
N/A N/A N/A N/A N/A N/A N/A

Flex Array Specifications

Third Party Array Compatibility Array LUN Absolute Min Raw Capacity Array LUN Block Size Default Array LUN RAID Group Size Array LUN Max RAID Groups Per Aggregate Max Array LUN Size Max Array LUN Raid Group Size Min Array LUN Size Min Array LUN Root Vol Size Min Array LUN RAID Group Size Min Array LUN Aggregate Size Array LUN neighborhood Visible Assigned Devices Array LUN Recommended Min RAW Capacity Spare Core Array LUN Min Size
Click here to go to IMT 17,280 GiB 512 bytes 8 150 15,675 GiB 26 1.05 GiB 634 GiB 1 300 GiB 0 28,800 GiB 326 GiB

Platform LED for FAS8200 2-Node Stretch MetroCluster, Fiber Bridge

LED Label LED Name Type Status Indicator Description
Front View
1 Chassis Power Config - On Green At least one of the two PSUs is delivering power to the system.
- - - Off Neither PSU is delivering power to the system.
2 Chassis Attention LED, front - On Amber The system halted or a fault occurred in the chassis.
- - - Off The system is operating normally.
3 Location LED on chassis front - On or flashing blue The LED has been manually activated to aid in physically locating equipment
- - - Off The LED has not been manually activated to aid in physically locating equipment
Back View
LED Label LED Name Type Status Indicator Description
0a Port SAS 2 LED Onboard Config Attention Yellow SAS link requires attention
- - - Off SAS link operates as normal
- - Link Green Link is established on at least one external SAS lane
- - - Off No link is established on any external SAS lane
0a Port SAS Onboard Config Link Green Link is established on at least one external SAS lane
- - - Off No link is established on any external SAS lane
0b Port SAS 2 LED Onboard Config Attention Yellow SAS link requires attention
- - - Off SAS link operates as normal
- - Link Green Link is established on at least one external SAS lane
- - - Off No link is established on any external SAS lane
0b Port SAS Onboard Config Link Green Link is established on at least one external SAS lane
- - - Off No link is established on any external SAS lane
0c Port SAS 2 LED Onboard Config Attention Yellow SAS link requires attention
- - - Off SAS link operates as normal
- - Link Green Link is established on at least one external SAS lane
- - - Off No link is established on any external SAS lane
0c Port SAS Onboard Config Link Green Link is established on at least one external SAS lane
- - - Off No link is established on any external SAS lane
0d Port SAS 2 LED Onboard Config Attention Yellow SAS link requires attention
- - - Off SAS link operates as normal
- - Link Green Link is established on at least one external SAS lane
- - - Off No link is established on any external SAS lane
0d Port SAS Onboard Config Link Green Link is established on at least one external SAS lane
- - - Off No link is established on any external SAS lane
e0a Port Ethernet SFP Config with arrow LEDs (Attention) Ethernet Port LED Amber Port requires attention
- - - Green A connection is established to the port.
- - - Off No connection is established on the port.
- - - Off Port operates normally
e0b Port Ethernet SFP Config with arrow LEDs (Attention) Ethernet Port LED Amber Port requires attention
- - - Green A connection is established to the port.
- - - Off No connection is established on the port.
- - - Off Port operates normally
e0c Port Ethernet Config Port Activity Blinking amber Traffic is flowing over the connection
- - - Off No traffic is flowing over the connection.
- - Port Link Green A connection is established on the port
- - - Off No connection is established on the port.
e0d Port Ethernet Config Port Activity Blinking amber Traffic is flowing over the connection
- - - Off No traffic is flowing over the connection.
- - Port Link Green A connection is established on the port
- - - Off No connection is established on the port.
e0e/0e Port Ethernet SFP Config with arrow LEDs (Attention) Ethernet Port LED Amber Port requires attention
- - - Green A connection is established to the port.
- - - Off No connection is established on the port.
- - - Off Port operates normally
e0e/0e Port UTA2 Arrow LED (FC Personality) Ethernet Port LED Green A connection is established to the port.
- - - Off No connection is established on the port.
e0f/0f Port Ethernet SFP Config with arrow LEDs (Attention) Ethernet Port LED Amber Port requires attention
- - - Green A connection is established to the port.
- - - Off No connection is established on the port.
- - - Off Port operates normally
e0f/0f Port UTA2 Arrow LED (FC Personality) Ethernet Port LED Green A connection is established to the port.
- - - Off No connection is established on the port.
e0g/0g Port Ethernet SFP Config with arrow LEDs (Attention) Ethernet Port LED Amber Port requires attention
- - - Green A connection is established to the port.
- - - Off No connection is established on the port.
- - - Off Port operates normally
e0g/0g Port UTA2 Arrow LED (FC Personality) Ethernet Port LED Green A connection is established to the port.
- - - Off No connection is established on the port.
e0h/0h Port Ethernet SFP Config with arrow LEDs (Attention) Ethernet Port LED Amber Port requires attention
- - - Green A connection is established to the port.
- - - Off No connection is established on the port.
- - - Off Port operates normally
e0h/0h Port UTA2 Arrow LED (FC Personality) Ethernet Port LED Green A connection is established to the port.
- - - Off No connection is established on the port.
e0M/SP Port Remote Management Config - Blinking amber Traffic is flowing over the connection.
- - - Green A link is established between the port and some upstream device.
- - - Off No link is established.
- - - Off No traffic is flowing over the connection.

Supported Shelves Drives for FAS8200 2-Node Stretch MetroCluster, Fiber Bridge

Part No.Capacity RPM Drive Type Encryption Root-Data Partitioning Root-Data-Data Partitioning Storage Pool Partitioning Max Drive Count FlexArray
DS212C with IOM12B / IOM12B / IOM12 / IOM12 shelf modules
X302A-R5 1TB 7.2K SATA No No No No 480 Yes
X306A-R5 2TB 7.2K SATA No No No No 480 Yes
X308A-R5 3TB 7.2K SATA No No No No 480 Yes
X318A-R6 8TB 7.2K NL-SAS No No No No 480 Yes
X336A-R6 4TB 7.2K NL-SAS No No No No 480 Yes
X339A 2TB 7.2K NL-SAS No No No No 480 Yes
X380A 10TB 7.2K NL-SAS No No No No 480 Yes
X388A 16TB 7.2K NL-SAS No No No No 480 Yes
X477A-R6 4TB 7.2K NL-SAS No No No No 480 Yes
X488A-R5 900GB 10K SAS No No No No 480 Yes
X489A-R6 1.2TB 10K SAS No No No No 480 Yes
X490A-R6 1.8TB 10K SAS No No No No 480 Yes
X363A-R6 3.84TB N/A SSD No No No No 480 Yes
X364A 3.84TB N/A SSD No No No No 480 Yes
X374A 960GB N/A SSD No No No No 480 Yes
X448A-R6 200GB N/A SSD No No No No 480 Yes
X449A-R6 800GB N/A SSD No No No No 480 Yes
X575A-R6 400GB N/A SSD No No No No 480 Yes
X576A-R6 1.6TB N/A SSD No No No No 480 Yes
DS224C with IOM12 / IOM12B / IOM12 / IOM12B shelf modules
X341A-R6 900GB 10K SAS No No No No 480 Yes
X342A-R6 1.2TB 10K SAS No No No No 480 Yes
X343A-R6 1.8TB 10K SAS No No No No 480 Yes
X421A-R5 450GB 10K SAS No No No No 480 Yes
X422A-R5 600GB 10K SAS No No No No 480 Yes
X423A-R5 900GB 10K SAS No No No No 480 Yes
X425A-R6 1.2TB 10K SAS No No No No 480 Yes
X426A-R6 1.8TB 10K SAS No No No No 480 Yes
X319A 7.6TB N/A SSD No No No No 480 Yes
X356A-R6 3.84TB N/A SSD No No No No 480 Yes
X357A 3.84TB N/A SSD No No No No 480 Yes
X359A 30.6TB N/A SSD No No No No 480 Yes
X371A 960GB N/A SSD No No No No 480 Yes
X438A-R6 400GB N/A SSD No No No No 480 Yes
X439A-R6 1.6TB N/A SSD No No No No 480 Yes
X446A-R6 200GB N/A SSD No No No No 480 Yes
X446B-R6 200GB N/A SSD No No No No 480 Yes
X447A-R6 800GB N/A SSD No No No No 480 Yes
X670A 15.3TB N/A SSD No No No No 480 Yes
DS460C with IOM12B / IOM12 / IOM12 / IOM12B shelf modules
X375A 4TB 7.2K NL-SAS No No No No 480 Yes
X376A 8TB 7.2K NL-SAS No No No No 480 Yes
X377A 10TB 7.2K NL-SAS No No No No 480 Yes
X379A 960GB N/A SSD No No No No 80 Yes
X387A 16TB 7.2K NL-SAS No No No No 480 Yes
DS2246 with IOM6 / IOM12 / IOM12 / IOM12B / IOM6 / IOM12B shelf modules
X341A-R6 900GB 10K SAS No No No No 480 Yes
X342A-R6 1.2TB 10K SAS No No No No 480 Yes
X343A-R6 1.8TB 10K SAS No No No No 480 Yes
X421A-R5 450GB 10K SAS No No No No 480 Yes
X422A-R5 600GB 10K SAS No No No No 480 Yes
X423A-R5 900GB 10K SAS No No No No 480 Yes
X425A-R6 1.2TB 10K SAS No No No No 480 Yes
X426A-R6 1.8TB 10K SAS No No No No 480 Yes
X356A-R6 3.84TB N/A SSD No No No No 480 Yes
X357A 3.84TB N/A SSD No No No No 480 Yes
X371A 960GB N/A SSD No No No No 480 Yes
X438A-R6 400GB N/A SSD No No No No 480 Yes
X439A-R6 1.6TB N/A SSD No No No No 480 Yes
X446A-R6 200GB N/A SSD No No No No 480 Yes
X446B-R6 200GB N/A SSD No No No No 480 Yes
X447A-R6 800GB N/A SSD No No No No 480 Yes
DS4246 with IOM12 / IOM6 / IOM6 / IOM12 / IOM12B / IOM12B shelf modules
X302A-R5 1TB 7.2K SATA No No No No 480 Yes
X306A-R5 2TB 7.2K SATA No No No No 480 Yes
X308A-R5 3TB 7.2K SATA No No No No 480 Yes
X316A-R6 6TB 7.2K NL-SAS No No No No 480 Yes
X318A-R6 8TB 7.2K NL-SAS No No No No 480 Yes
X336A-R6 4TB 7.2K NL-SAS No No No No 480 Yes
X380A 10TB 7.2K NL-SAS No No No No 480 Yes
X477A-R6 4TB 7.2K NL-SAS No No No No 480 Yes
X488A-R5 900GB 10K SAS No No No No 480 Yes
X489A-R6 1.2TB 10K SAS No No No No 480 Yes
X490A-R6 1.8TB 10K SAS No No No No 480 Yes
X363A-R6 3.84TB N/A SSD No No No No 480 Yes
X374A 960GB N/A SSD No No No No 480 Yes
X441A-R5 100GB N/A SSD No No No No 480 Yes
X442A-R5 [2] 100GB N/A SSD No No No No 480 Yes
X448A-R6 200GB N/A SSD No No No No 480 Yes
X449A-R6 800GB N/A SSD No No No No 480 Yes
X575A-R6 400GB N/A SSD No No No No 480 Yes
X576A-R6 1.6TB N/A SSD No No No No 480 Yes
DS4243 [1] with IOM12 / IOM6 shelf modules
X302A-R5 1TB 7.2K SATA No No No No 480 Yes
X306A-R5 2TB 7.2K SATA No No No No 480 Yes
X308A-R5 3TB 7.2K SATA No No No No 480 Yes
Footnote:
1The DS4243 shelf requires an upgrade to IOM6 or IOM12 Expander Modules for support with FAS26x0, FAS8200, and FAS9000 platforms.
2This drive does not support the sanitization feature.

Supported RAID Configurations - FAS8200 2-Node Stretch MetroCluster, Fiber Bridge

Drive Type Drive Capacity Min Drive Capacity Max Minimum Default Maximum
Data Aggregate
RAID4
NL-SAS 0 TB 8 TB 3 7 7
SAS 0 TB 5.999 TB 3 8 14
SATA 0 TB 5.999 TB 3 7 7
SSD 0 TB 30.6 TB 3 8 14
RAID-DP
NL-SAS 0 TB 5.999 TB 5 14 20
NL-SAS 6 TB 10 TB 5 14 14
SAS 0 TB 5.999 TB 5 16 28
SATA 0 TB 5.999 TB 5 14 20
SSD 0 TB 30.6 TB 5 24 28
RAID-TEC
NL-SAS 0 TB 16 TB 7 21 29
SAS 0 TB 8 TB 7 24 29
SATA 0 TB 8 TB 7 21 29
SSD 0 TB 30.6 TB 7 25 29
Root Aggregate
RAID4
NL-SAS 0 TB 8 TB 2 - 7
SAS 0 TB 5.999 TB 2 - 14
SATA 0 TB 5.999 TB 2 - 7
SSD 0 TB 30.6 TB 2 - 14
RAID-DP
NL-SAS 0 TB 5.999 TB 3[1] - 20
NL-SAS 6 TB 16 TB 3[1] - 14
SAS 0 TB 5.999 TB 3[1] - 28
SATA 0 TB 5.999 TB 3[1] - 20
SSD 0 TB 30.6 TB 3[1] - 28
RAID-TEC
NL-SAS 0 TB 16 TB 7 - 29
SAS 0 TB 8 TB 7 - 29
SATA 0 TB 8 TB 7 - 29
SSD 0 TB 30.6 TB 7 - 29
Footnote:
1The minimum number of disks in a RAID-DP group is three: at least one data disk, one regular parity disk, and one double-parity (dParity) disk. However, for non-root aggregates with only one RAID group, you must have at least 5 disks (three data disks and two parity disks).

Supported Adapter Cards - FAS8200 2-Node Stretch MetroCluster, Fiber Bridge

install long reach SFPs, X65403, in ports 3 and 4.

Priority Category Bus Type Mktg Part No. Mfg Part No Description Plug Type Optical Module Included? Cables Supported Protocol(s) Min ONTAP Max Qty [1] Priority Slot Assignment
1 MetroCluster PCIe X1928A-R6 111-00941 Fibre Channel 4/8/16 Gb 111-00941 2p 16Gb FC-VI SFP+ SFP+ Fibre Channel 4/8/16 Gb View Fibre Channel 4/8/16 Gb 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
2 Networking PCIe X1117A-R6 111-01232,111-00754 Ethernet 10Gb 111-01232, 2p 10GbE NIC Cu|Op SFP+ Ethernet 10Gb View Ethernet 10Gb 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
3 Networking PCIe3 X1144A 111-03380 Ethernet 40Gb,Ethernet 40Gb w/4x10Gb breakout 111-03380 2p 40GbE NIC Cu|Op QSFP+ Ethernet 40Gb,Ethernet 40Gb w/4x10Gb breakout View Ethernet 40Gb, 9.1RC2, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
4 Networking (Target) PCIe X1143A-R6 111-00910 Ethernet 10Gb,Fibre Channel 4/8/16 Gb 111-00910 2p 16Gb|10Gb UTA2 Cu|Op SFP+ Ethernet 10Gb,Fibre Channel 4/8/16 Gb View Ethernet 10Gb, 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
5 Networking PCIe X1120A-R6 111-01688 Ethernet 1/10 Gb 111-01688 2p 10GBASE-T NIC Cu RJ45 Ethernet 1/10 Gb View Ethernet 1/10 Gb 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
6 Block Access (Target) PCIe3 X1134A [2] 111-03249 Fibre Channel 8/16/32 Gb 111-03249 2p 32Gb FC SFP+ Op (Target Only) SFP+ Fibre Channel 8/16/32 Gb View Fibre Channel 8/16/32 Gb 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
7 Block Access (Target) PCIe X1143A-R6 111-00910 Ethernet 10Gb,Fibre Channel 4/8/16 Gb 111-00910 2p 16Gb|10Gb UTA2 Cu|Op SFP+ Ethernet 10Gb,Fibre Channel 4/8/16 Gb View Ethernet 10Gb, 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
8 Block Access (Target) PCIe3 X1133A-R6 111-02451 Fibre Channel 4/8/16 Gb 111-02451 4p 16Gb FC SFP+ Op SFP+ Fibre Channel 4/8/16 Gb View Fibre Channel 4/8/16 Gb 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
9 Block Access (Target) PCIe X1132A-R6 111-00481 Fibre Channel 2/4/8 Gb 111-00481 4p 8Gb FC Op SFP Fibre Channel 2/4/8 Gb View Fibre Channel 2/4/8 Gb 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
10 Performance Acceleration M.2 PCIe X3311A 111-03066 111-03066 Flash Cache,1.0TB,NVMe N/A 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
11 Block Access (Target) PCIe X1130A-R6 111-00416 Fibre Channel 1/2/4 Gb 111-00416 4p 4Gb FC Op LC Fibre Channel 1/2/4 Gb View Fibre Channel 1/2/4 Gb 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
12 Networking PCIe X1049C-R6 111-01034 Ethernet 10/100/1000 Mb 111-01034 4p 1GbE NIC Cu RJ45 Ethernet 10/100/1000 Mb View Ethernet 10/100/1000 Mb 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
13 Networking PCIe X1048A-R6 111-00909 Ethernet 10/100/1000 Mb 111-00909 4p 1GbE NIC Op LC Ethernet 10/100/1000 Mb View Ethernet 10/100/1000 Mb 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
14 Storage (Initiator) PCIe3 X1145A [3] 111-02455 Fibre Channel 4/8/16 Gb 111-02455 4p 16Gb FC Op SFP+ Fibre Channel 4/8/16 Gb View Fibre Channel 4/8/16 Gb 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
15 Storage (Initiator) PCIe3 X1133A-R6 111-02451 Fibre Channel 4/8/16 Gb 111-02451 4p 16Gb FC SFP+ Op SFP+ Fibre Channel 4/8/16 Gb View Fibre Channel 4/8/16 Gb 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
16 Storage (Initiator) PCIe X1132A-R6 [4] 111-00481 Fibre Channel 2/4/8 Gb 111-00481 4p 8Gb FC Op SFP Fibre Channel 2/4/8 Gb View Fibre Channel 2/4/8 Gb 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
17 Storage (Initiator) PCIe X1143A-R6 [5] 111-00910 Ethernet 10Gb,Fibre Channel 4/8/16 Gb 111-00910 2p 16Gb|10Gb UTA2 Cu|Op SFP+ Ethernet 10Gb,Fibre Channel 4/8/16 Gb View Ethernet 10Gb, 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
18 Tape (Initiator) PCIe X1143A-R6 [6] 111-00910 Ethernet 10Gb,Fibre Channel 4/8/16 Gb 111-00910 2p 16Gb|10Gb UTA2 Cu|Op SFP+ Ethernet 10Gb,Fibre Channel 4/8/16 Gb View Ethernet 10Gb, 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
19 Tape (Initiator) PCIe3 X1133A-R6 [6] 111-02451 Fibre Channel 4/8/16 Gb 111-02451 4p 16Gb FC SFP+ Op SFP+ Fibre Channel 4/8/16 Gb View Fibre Channel 4/8/16 Gb 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
20 Tape (Initiator) PCIe X1132A-R6 111-00481 Fibre Channel 2/4/8 Gb 111-00481 4p 8Gb FC Op SFP Fibre Channel 2/4/8 Gb View Fibre Channel 2/4/8 Gb 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
21 Tape (Initiator) PCIe X2069-R6 111-02026 SAS 3/6/12 Gb 111-02026 4p 12Gb SAS Cu|Op QSFP SAS 3/6/12 Gb View SAS 3/6/12 Gb 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
22 Tape (Initiator) PCIe X2054A-R6 111-00285 Fibre Channel 1/2/4 Gb 111-00285 4p 4Gb FC Op LC Fibre Channel 1/2/4 Gb View Fibre Channel 1/2/4 Gb 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
Footnote:
[1] Values shown for max quantity are per controller.  HA configurations will support 2x the values shown.
[2] Target mode adapter only. Foreign LUN import (FLI) requires initiator mode.
[3] Install short reach SFPs, X6596-R6, in ports 1 and 2
Priority Category Bus Type Mktg Part No. Mfg Part No Description Plug Type Optical Module Included? Cables Supported Protocol(s) Min ONTAP Max Qty [1] Priority Slot Assignment
[4] X1132A-R6 adapter card does not support ATTO 7600N switch
[5] UTA2 ports can be configured as FC target/initiator or CNA (10GbE Ethernet) mode. Both ports must be configured for the same mode and use same SFP+ type. Refer to the Cables link in this table to view supported SFP+ modules or copper twinax cables used in FC or CNA mode.
[6] Connecting tape drives or tape libraries to FC or UTA2 ports requires the use of an FC switch.

-

Configuration Type Port Configuration Image Cluster Ports per Node Switch Ports per Node

Platform Mixing Rules - FAS8200 2-Node Stretch MetroCluster

Platform Configuration Type Maximum Nodes (NAS) [1] Maximum Nodes (SAN) [1] Min ONTAP Version for Platform Mixing
FAS - Legacy EOA Configuration(s)
FAS8200-2NBSMC 1 Nodes 1 Nodes 9.1RC1
Footnote:
1Maximum number of nodes within a cluster is determined by platform which supports the fewest number of nodes

Product Standard Compliance - FAS8200 2-Node Stretch MetroCluster, Fiber Bridge

Standard Description
Certifications EMC/EMI
AMCA Australia and New Zealand (EMC covered by ACMA DoC)
FCC Federal Communications Commission (EMI Declaration of Conformity covering United States and Canada)
ICES ICES
KC Korea Communications Commission (EMC certificate for South Korea)
Morocco Morocco Declaration of Conformity
VCCI EMI Certificate for Japan
Certifications safety
BIS Bureau of Indian Standard (Safety cert for India)
CB Certificate Body issued safety certificate covering International
CSA Canadian Standards Association issued Safety certificate covering North America
G_K_U-SoR Safety certificate for Gabon, Kenya and Uganda
IRAM Instituto Argentino de Normalización y Certificación (safety certificate for Argentina)
NOM Norma Oficial Mexicana (Safety cert for Mexico)
NRCS National Regulator for Compulsory Specifications (Safety cert for South Africa)
SONCAP Standards Organisation of Nigeria Conformity Assessment Programme (Safety cert for Nigeria)
TBS Tanzanian Bureau of Standards (Safety certificate for Tanzania)
Certifications Safety/EMC/EMI
EAC Euro Asia Conformity (EMC and Safety Cert) covering (Russia, Kazakhstan, Belarus, Armenia, Kyrgyzstan Countries)
UKRSEPRO EMC/Safety certificate for Ukraine
Certifications Safety/EMC/EMI/RoHS
BSMI Certificate for Taiwan
CE DoC European Union Declaration of Conformity
UKCA DoC UK Declaration of Conformity
Standards EMC/EMI
BS-EN-55024 EMC standard for Great Britain
BS-EN55035 EMC standard for Great Britain
CISPR 32 EMI
EN55022 EMC Standard fo European Union
EN55024 EMC Standard fo European Union
EN55032 EMI Standard fo European Union
EN55035 EMC Standard for European Union
EN61000-3-2 EMC Standard for European Union
EN61000-3-3 EMC Standard for European Union
FCC Part 15 Class A EMI standard for United States
ICES-003 EMI Standard for Canada
KS C 9832 EMI Standard for South Korea
KS C 9835 EMC Standard for South Korea
Standards Safety
ANSI/UL60950-1 Safety standard for United States
ANSI/UL62368-1 Safety standard for United States
BS-EN62368-1 Safety standard for Great Britain
CAN/CSA C22.2 No. 60950-1 Safety Standard for Canada
CAN/CSA C22.2 No. 62368-1 Safety Standard for Canada
CNS 14336 Safety Standard for Taiwan
EN60825-1 Laser Safety standard for European Union
EN62368-1 Safety standard for European Union
IEC 62368-1 Safety Standard for International
IEC60950-1 Safety standard for International
IS 13252(part 1) Safety Standard for India

Supported OS Version - FAS8200 2-Node Stretch MetroCluster, Fiber Bridge

OS Major Version Supported OS Version Supported Milestones Recommend Version
Currently Supported OS
ONTAP 9.11.1 9.11.1, 9.11.1RC1 End of Full Support: 31-Jul-2025
End of Limited Support: 31-Jul-2027
End of Self-Service Support: 31-Jul-2030
9.11.1
ONTAP 9.10.1 9.10.1P5, 9.10.1P6, 9.10.1P4, 9.10.1P3, 9.10.1P2, 9.10.1P1, 9.10.1, 9.10.1RC1 End of Full Support: 31-Jan-2025
End of Limited Support: 31-Jan-2027
End of Self-Service Support: 31-Jan-2030
9.10.1P6
ONTAP 9.9.1 9.9.1P11, 9.9.1P10, 9.9.1P9, 9.9.1P8, 9.9.1P7, 9.9.1P6, 9.9.1P5, 9.9.1P4, 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 End of Full Support: 30-Jun-2024
End of Limited Support: 30-Jun-2026
End of Self-Service Support: 30-Jun-2029
9.9.1P11, 9.9.1P10, 9.9.1P9
ONTAP 9.8 9.8P13, 9.8P12, 9.8P11, 9.8P10, 9.8P9, 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4, 9.8P3, 9.8P2, 9.8P1, 9.8, 9.8RC1 End of Full Support: 31-Dec-2023
End of Limited Support: 31-Dec-2025
End of Self-Service Support: 31-Dec-2028
9.8P13, 9.8P12
ONTAP 9.7 9.7P19, 9.7P18, 9.7P17, 9.7P16, 9.7P15, 9.7P14, 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 End of Full Support: 31-Jan-2023
End of Limited Support: 31-Jan-2025
End of Self-Service Support: 31-Jan-2028
9.7P19
EOS OS
ONTAP 9.7 9.7P19, 9.7P18, 9.7P17, 9.7P16, 9.7P15, 9.7P14, 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 End of Full Support: 31-Jan-2023
End of Limited Support: 31-Jan-2025
End of Self-Service Support: 31-Jan-2028
9.7P19
ONTAP 9.6 9.6P18, 9.6P17, 9.6P16, 9.6P15, 9.6P14, 9.6P13, 9.6P12, 9.6P11, 9.6P10, 9.6P9, 9.6P8, 9.6P7, 9.6P6, 9.6P5, 9.6P4, 9.6P3, 9.6P2, 9.6P1, 9.6, 9.6RC2, 9.6RC1 End of Full Support: 30-Jun-2022
End of Limited Support: 30-Jun-2024
End of Self-Service Support: 30-Jun-2027
9.6P18
ONTAP 9.5 9.5P19, 9.5P18, 9.5P17, 9.5P16, 9.5P15, 9.5P14, 9.5P13, 9.5P12, 9.5P11, 9.5P10, 9.5P9, 9.5P8, 9.5P7, 9.5P6, 9.5P5, 9.5P4, 9.5P3, 9.5P2, 9.5P1, 9.5, 9.5RC1 End of Full Support: 31-Jan-2022
End of Limited Support: 31-Jan-2024
End of Self-Service Support: 31-Jan-2027
9.5P19
ONTAP 9.4 9.4P8, 9.4P7, 9.4P6, 9.4P5, 9.4P4, 9.4P3, 9.4P2, 9.4P1, 9.4, 9.4RC1 End of Full Support: 30-Jun-2019
End of Limited Support: 30-Jun-2021
End of Self-Service Support: 30-Jun-2024
9.4P8
ONTAP 9.3 9.3P21, 9.3P20, 9.3P19, 9.3P18, 9.3P17, 9.3P16, 9.3P15, 9.3P14, 9.3P13, 9.3P12, 9.3P11, 9.3P10, 9.3P9, 9.3P8, 9.3P7, 9.3P6, 9.3P5, 9.3P4, 9.3P3, 9.3P2, 9.3P1, 9.3, 9.3RC1 End of Full Support: 31-Jan-2021
End of Limited Support: 31-Jan-2023
End of Self-Service Support: 31-Jan-2026
9.3P21
ONTAP 9.2 9.2P4, 9.2P3, 9.2P2, 9.2P1, 9.2, 9.2RC1 End of Full Support: 31-Jul-2018
End of Limited Support: 31-Jul-2020
End of Self-Service Support: 31-Jul-2023
9.2P4
Definitions:
[1]End of Full Support: The date marking the end of Full Support for a particular feature version of a NetApp system software and the beginning of Limited Support. Abbreviated as EOES.
[2]End of Limited Support: The date marking the end of Limited Support for a particular feature version of a product and transition to Self-Service Support. Abbreviated as EOVS.
[3]End of Self-Service Support: NetApp does not provide support for a version of a software product, but related documentation is still available on the NetApp Support Site. NetApp customers are expected to utilize documentation to resolve issues.

Supported Power Cords for FAS8200 2-Node Stretch MetroCluster, Fiber Bridge

Marketing Part No.End 1 / End 2LengthDescription
Non-Cabinet Power Cords
X-50617-00 IEC60320-C20 / IEC60320-C13 2.00 m Power Cords,In-Cabinet,2m,C20-C13,E-Series
X800B-R6 CEE 7/7 (Schuko) / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Cont Europe/Korea,10A/250V
X800C-R6 BS1363 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,UK/Ireland,10A/250V
X800D-R6 JIS-C-8303 / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,Japan,15A/125V
X800E-R6 NEMA 5-15P / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,North America,15A/125V
X800F-R6 AS/NZS 3112 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Aus/NZ,10A/250V
X800G-R6 SEV 1011 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Switzerland,10A/250V
X800H-R6 IRAM 2073 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Argentina,10A/250V
X800I-R6 GB2099 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,China,10A/250V
X800J-R6 DHCR107-2-D1 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Demark,10A/250V
X800K-R6 SANS 164-1 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,India/S.Africa,10A/250V
X800L-R6 SI32 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Israel,10A/250V
X800M-R6 CEI 23-16 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Italy,10A/250V
X800P-R6 NEMA 6-15P / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,North America,15A/250V
X800T-R6 CNS 10917-3 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Taiwan,BSMI,15A/125V
X800VB-R6 NBR14136 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Brazil,10A/250V
X800W-R6 CNS10917/CNS690 / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,Taiwan,10A/250V
X800Y-R6 JIS-C-830 / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,Japan,15A/250V
In-Cabinet Power Cords
X-52197-00-R6 IEC60320-C14 / IEC60320-C13 2.00 m Pwr Cord,In-Cabinet, C14-C13,E-Series, 2M
X1558A-R6 IEC60320-C14 / IEC60320-C13 1.20 m Pwr Cord,In-Cabinet,48-In,C13-C14,10A/250V
X800-42U-35 IEC60320-C14 / IEC60320-C13 0.89 m Pwr Cord,In-Cabinet,C13-C14,35-inch
X800-42U-43 IEC60320-C14 / IEC60320-C13 1.09 m Pwr Cord,In-Cabinet,C13-C14,43-inch
X800-42U-64 IEC60320-C14 / IEC60320-C13 1.63 m Pwr Cord,In-Cabinet,C13-C14,64-inch
X800-42U-R6 IEC60320-C14 / IEC60320-C13 0.68 m Pwr Cord,In-Cabinet,27-In,C13-C14,10A/250V

Onboard Ports Configuration: FAS8200 2-Node Stretch MetroCluster

Port Address Description Supported Protocols Port Icon Port Type
0a Serial-Attached SCSI SAS 6/12 Gb SAS MiniSAS HD
0b Serial-Attached SCSI SAS 6/12 Gb SAS MiniSAS HD
0c Serial-Attached SCSI SAS 6/12 Gb SAS MiniSAS HD
0d Serial-Attached SCSI SAS 6/12 Gb SAS MiniSAS HD
e0a [1] Ethernet Ethernet 10Gb Ethernet SFP+
e0b [1] Ethernet Ethernet 10Gb Ethernet SFP+
e0c Ethernet Ethernet 10Gb Base-T (1000/10000 Mb) Ethernet RJ45
e0d Ethernet Ethernet 10Gb Base-T (1000/10000 Mb) Ethernet RJ45
e0e/0e [2] Unified Target Adapter 2 Ethernet 1/10 Gb, FC-VI, Fibre Channel 4/8/16 Gb Ethernet/Fibre Channel SFP+
e0f/0f [2] Unified Target Adapter 2 Ethernet 1/10 Gb, FC-VI, Fibre Channel 4/8/16 Gb Ethernet/Fibre Channel SFP+
e0g/0g [2] Unified Target Adapter 2 Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb Ethernet/Fibre Channel SFP+
e0h/0h [2] Unified Target Adapter 2 Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb Ethernet/Fibre Channel SFP+
e0M/SP [3] Management Ethernet 10/100/1000 Mb Wrench RJ45
Serial Interface Serial Console RS-232 115200bps Serial Interface RJ45
Serial Interface USB Serial Console RS-232 115200bps USB 2.0 USB 2.0 Micro-B
USB/2 Storage Host Port USB 2.0 USB 2.0 USB Type A
Footnote:
[1] See Cluster Interconnect Tab for Cluster-Specific Interconnect Requirements
[2] Connecting tape drives or tape libraries to the FC or UTA2 ports requires the use of a FC switch.
[3] e0M is default management port

Supported Platform Configurations - FAS8200 2-Node Stretch MetroCluster, Fiber Bridge

Platform Configuration Description Chassis Configuration Chassis Count Controller Count (per chassis) IOXM Count (per chassis) Rack Units (Per System) Weight (Per Chassis) Min ONTAP
HA Pair
FAS8200A FAS8200 Single Chassis HA Pair CC 1 2 0 3 76.00 lb (34.473 kg) 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
MetroCluster
FAS8200-2NBSMC FAS8200 2-Node Stretch MetroCluster, Fiber Bridge Cb-HA 2 1 0 6 65.80 lb (29.846 kg) 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
FAS8200-2NDSMC FAS8200 2-Node Stretch MetroCluster, Optical SAS Cb-HA 2 1 0 6 65.80 lb (29.846 kg) 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
FAS8200-2NFMC FAS8200 2-Node Fabric MetroCluster Cb-HA 2 1 0 6 65.80 lb (29.846 kg) 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
FAS8200-4NFMC FAS8200 4-Node Fabric MetroCluster CC-CC 2 2 0 6 76.00 lb (34.473 kg) 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
FAS8200-4NMCIP FAS8200 4-Node MetroCluster IP CC-CC 2 2 0 6 76.00 lb (34.473 kg) 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
FAS8200-8NFMC FAS8200 8-Node Fabric MetroCluster 2x(CC-CC) 4 2 0 12 76.00 lb (34.473 kg) 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
FAS8200-8NMCIP FAS8200 8-Node MetroCluster IP 2x(CC-CC) 4 2 0 12 76.00 lb (34.473 kg) 9.9.1RC1, 9.10.1RC1, 9.11.1RC1

Platform Memory Specifications - FAS8200 2-Node Stretch MetroCluster, Fiber Bridge

Part Number Description Mfg Part Number Non-Volatile Qty Capacity (GB) NVRAM/NVMEM Used Capacity (GB) RAM Used Capacity (GB)
X93142A DIMM,32GB 107-00176 no 8 32 16 256

Supported Rail Kit for FAS8200 2-Node Stretch MetroCluster, Fiber Bridge

Marketing Part No.Manufacturing Part No.Description
NetApp System Cabinet Rail Kits
X8783A-R6 111-01110 Rail Kit III, NetApp Cabinet, R6
X87880A 111-03887 Rail Kit 4,Cabinet
Third-Party Cabinet Rail Kits
X-02659-00 113-00232 Kit,4-Post,Square or Round-Hole, 24"-32" Rail
X5515A-R6 111-00232 Kit,2-Post (Round) or 4-Post (Square), 24"-32" Rail
X5529A-R6 111-00310 Kit,4-Post,Swift,Square-Hole, 24"-32" Rail

Field Replacement Unit Parts - FAS8200 2-Node Stretch MetroCluster, Fiber Bridge

Marketing Part No.Manufacturing Part No.Description
Adapter Card
X1048A-EN-R6-C 111-00909 NIC 4-Port Optical GbE PCIe,EN,-C
X1048A-R6 111-00909 NIC 4-Port Optical GbE PCIe
X1048A-R6-C 111-00909 NIC 4-Port Optical GbE PCIe,-C
X1049C-R6 111-01034 NIC 4-Port Copper GbE II PCIe
X1049C-R6-C 111-01034 NIC 4-Port Copper GbE II PCIe,-C
X1117A-EN-R6-C 111-00754, 111-01232 NICII 2-Port Bare Cage SFP+ 10GbE PCIe,EN,-C
X1117A-N-C 111-00754, 111-01232 NICII 2-Port Bare Cage SFP+ 10GbE PCIe,-C
X1117A-R6 111-00754, 111-01232 NICII 2-Port Bare Cage SFP+ 10GbE PCIe
X1117A-R6-C 111-00754, 111-01232 NICII 2-Port Bare Cage SFP+ 10GbE PCIe,-C
X1120A-N-C [1] 111-01688 NIC II 2-Port RJ45 10GBASE-T PCIe,-C
X1120A-R6 [1] 111-01688 NIC II 2-Port RJ45 10GBASE-T PCIe
X1120A-R6-C [1] 111-01688 NIC II 2-Port RJ45 10GBASE-T PCIe,-C
X1130A-EN-R6-C 111-00416 HBA 4-Port FCP Target 4Gb PCIe,EN,-C
X1130A-R6 111-00416 HBA 4-Port FCP Target 4Gb PCIe
X1132A-EN-R6-C [2] 111-00481 ADPT 4-Port FCP 8Gb Target Adapter PCIe,EN,-C
X1132A-R6 [2] 111-00481 ADPT 4-Pt FC 8Gb Target-Init PCIe
X1132A-R6-C [2] 111-00481 ADPT 4-Pt FC 8Gb Target-Init PCIe,-C
X1133A-N-C [3] [4] 111-02451 HBA,4-Port FCP Trgt/Init 16Gb PCIe w/SFP+,-C
X1133A-R6 [3] [4] 111-02451 HBA,4-Port FCP Trgt/Init 16Gb PCIe w/SFP+
X1133A-R6-C [3] [4] 111-02451 HBA,4-Port FCP Trgt/Init 16Gb PCIe w/SFP+,-C
X1134A [5] 111-03249 HBA,2-Port FCP Target 32Gb PCIe w/SFP+
X1134A-C [5] 111-03249 HBA,2-Port FCP Target 32Gb PCIe w/SFP+,-C
X1134A-N-C [5] 111-03249 HBA,2-Port FCP Target 32Gb PCIe w/SFP+,-C
X1143A-N-C [4] [6] [7] [8] [9] [10] [11] [12] 111-00910 ADPT 2-Pt UTA2,10GbE,16Gb FC BareCage SFP+,-C
X1143A-R6 [4] [6] [7] [8] [9] [10] [11] [12] 111-00910 ADPT 2-Pt UTA2,10GbE,16Gb FC BareCage SFP+
X1143A-R6-C [4] [6] [7] [8] [9] [10] [11] [12] 111-00910 ADPT 2-Pt UTA2,10GbE,16Gb FC BareCage SFP+,-C
X1144A [13] [14] 111-03380 NIC 2-Port Bare Cage 40GbE QSFP+ PCIe
X1144A-C [13] [14] 111-03380 NIC 2-Port Bare Cage 40GbE QSFP+ PCIe,-C
X1144A-N-C [13] [14] 111-03380 NIC 2-Port Bare Cage 40GbE QSFP+ PCIe,-C
X1145A [15] [16] 111-02455 HBA,4-Port FCP Init 16Gb PCIe Bare Cage
X1145A-C [15] [16] 111-02455 HBA,4-Port FCP Init 16Gb PCIe Bare Cage,-C
X1145A-N-C [15] [16] 111-02455 HBA,4-Port FCP Init 16Gb PCIe Bare Cage,-C
X1928A-R6 111-00941 HBA,MC FC-VI 16Gb PCIe w/5M Cbl w/o SFP
X1928A-R6-C 111-00941 HBA,MC FC-VI 16Gb PCIe w/5M Cbl w/o SFP,-C
X1928A-R6-N-C 111-00941 HBA,MC FC-VI 16Gb PCIe w/5M Cbl w/o SFP,-C
X2054A-EN-R6-C 111-00285 HBA 4-Port Optical 4Gb Disk PCIe,EN,-C
X2054A-R6 111-00285 HBA 4-Port Optical 4Gb Disk PCIe
X2069-R6 111-02026 HBA,4-Port SAS 3/6/12Gbps QSFP PCIe
X2069-R6-C 111-02026 HBA,4-Port SAS 3/6/12Gbps QSFP PCIe,-C
X3311A 111-03066 SUB ASSY,NVME,FLASH,1.0TB
Battery
X1847 271-01847 Lithium System Battery CR2032
X1847-R6 271-01847 Lithium System Battery CR2032,R6
X3150A 111-02490 BATT,4CELL,HiAh,HOLDER,FAS8200,A300
Bezel
X80104A 111-02492 Bezel,Sub Assembly,FAS8200
Boot Media
X3320A 501-01119 DRIVE,SSD,128GB,mSATA
Cable Management Guide
X3321A 111-02659 SUB ASSY,SM,BKT,CBL MGMNT SET,FAS8200,A300
Chassis
X3160A 111-02491 CHAS ASSY,W/MIDPLANE,NO FAN/PSU,FAS8200
Controller Blank
X3118-R6 111-00597 Blanking Panel,SYS CNTRL,32XX,8020,A300,8200
X3118-R6-C 111-00597 Blanking Panel,SYS CNTRL,32XX,-C,8020
Data Cable
X-QSFP-4SFP10G-CU3M 112-00602 Cable,Cisco,QSFP/4xSFP10G,CU Passive,3m
X-QSFP-4SFP10G-CU3M-C 112-00602 Cable,Cisco,QSFP/4xSFP10G,CU Passive,3m,-C
X-QSFP-4SFP10G-CU3M-N-C 112-00602 Cable,Cisco,QSFP/4xSFP10G,CU Passive,3m,-C
X-QSFP-4SFP10G-CU5M 112-00603 Cable,Cisco,QSFP/4xSFP10G,CU Passive,5m
X-QSFP-4SFP10G-CU5M-C 112-00603 Cable,Cisco,QSFP/4xSFP10G,CU Passive,5m,-C
X-QSFP-4SFP10G-CU5M-N-C 112-00603 Cable,Cisco,QSFP/4xSFP10G,CU Passive,5m,-C
X-QSFP-H40G-CU1M-R6 112-00307 Cable,Cisco 40GB Twinax Copper QSFP+ 1M
X-QSFP-H40G-CU1M-R6-C 112-00307 Cable,Cisco 40GB Twinax Copper QSFP+ 1M,-C
X-QSFP-H40G-CU1M-R6-N-C 112-00307 Cable,Cisco 40GB Twinax Copper QSFP+ 1M,-C
X-QSFP-H40G-CU3M-R6 112-00604 Cable,Cisco 40GB Twinax Copper QSFP+ 3M
X-QSFP-H40G-CU3M-R6-C 112-00604 Cable,Cisco 40GB Twinax Copper QSFP+ 3M,-C
X-QSFP-H40G-CU3M-R6-N-C 112-00604 Cable,Cisco 40GB Twinax Copper QSFP+ 3M,-C
X-QSFP-H40G-CU5M-R6 112-00604, 112-00605 Cable,Cisco 40GB Twinax Copper QSFP+ 5M
X-QSFP-H40G-CU5M-R6-C 112-00605 Cable,Cisco 40GB Twinax Copper QSFP+ 5M,-C
X-QSFP-H40G-CU5M-R6-N-C 112-00605 Cable,Cisco 40GB Twinax Copper QSFP+ 5M,-C
X-SFP-H10GB-CU1M-R6 112-00210 Cable,10GBase Copper SFP+ 1m
X-SFP-H10GB-CU1M-R6-C 112-00210 Cable,10GBase Copper SFP+ 1m,-C
X-SFP-H10GB-CU1M-R6-N-C 112-00210 Cable,10GBase Copper SFP+ 1m,-C
X-SFP-H10GB-CU3M-R6 112-00211 Cable,10GBase Copper SFP+ 3m
X-SFP-H10GB-CU3M-R6-C 112-00211 Cable,10GBase Copper SFP+ 3m,-C
X-SFP-H10GB-CU3M-R6-N-C 112-00211 Cable,10GBase Copper SFP+ 3m,-C
X-SFP-H10GB-CU5M-R6 112-00212 Cable,10GBase Copper SFP+ 5m
X-SFP-H10GB-CU5M-R6-C 112-00212 Cable,10GBase Copper SFP+ 5m,-C
X-SFP-H10GB-CU5M-R6-N-C 112-00212 Cable,10GBase Copper SFP+ 5m,-C
X1983-1-R6 112-00210 Cable,Twinax CU,SFP+,1M,X1962/X1963/X1967
X1983-3-R6 112-00211 Cable,Twinax CU,SFP+,3M,X1962/X1963/X1967
X1983-5-R6 112-00212 Cable,Twinax CU,SFP+,5M,X1962/X1963/X1967
X6536-R6 112-00090 Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op
X6536-R6-C 112-00090 Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op,-C
X6536-R6-N-C 112-00090 Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op,-C
X6537-R6 112-00091 Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op
X6537-R6-C 112-00091 Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op,-C
X6537-R6-N-C 112-00091 Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op,-C
X65420 112-00508 Cable,ASSY,USB 2.0 MICRO-B,USB-A,2M
X6546-R6 112-00074 Cable,Cntlr-Shelf/Switch,30m,LC/SC,Op
X6547-R6 112-00073 Cable,Cntlr-Shelf/Switch,5m,LC/SC,Op
X6553-R6 112-00188 Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op
X6553-R6-C 112-00188 Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op,-C
X6553-R6-N-C 112-00188 Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op,-C  
X6554-R6 112-00189 Cable,Cntlr-Shelf/Switch,15m,LC/LC,Op
X6554-R6-C 112-00189 Cable,OPT,50u,2GHz/KM,MM,LC/LC,15M,-C,R6
X6554-R6-N-C 112-00189 Cable,OPT,50u,2GHz/KM,MM,LC/LC,15M,-C,R6,-C
X6557-EN-R6-C 112-00176 Cbl,SAS Cntlr-Shelf/Shelf-Shelf/HA,0.5m,EN,-C
X6557-R6 112-00176 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,0.5m
X6557-R6-C 112-00176 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,0.5m,-C
X6558-EN-R6-C 112-00177 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,2m,-C
X6558-R6 112-00177 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,2m
X6558-R6-C 112-00177 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,2m,-C
X6559-EN-R6-C 112-00178 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,5m,-C
X6559-R6 112-00178 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,5m
X6559-R6-C 112-00178 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,5m,-C
X6560-R6 112-00194 Cable,Ethernet,0.5m RJ45 CAT6
X6560-R6-C 112-00194 Cable,Ethernet,0.5m RJ45 CAT6,-C
X6560-R6-N-C 112-00194 Cable,Ethernet,0.5m RJ45 CAT6
X6561-R6 112-00195 Cable,Ethernet,2m RJ45 CAT6
X6561-R6-C 112-00195 Cable,Ethernet,2m RJ45 CAT6,-C
X6561-R6-N-C 112-00195 Cable,Ethernet,2m RJ45 CAT6,-C
X6562-R6 112-00196 Cable,Ethernet,5m RJ45 CAT6
X6562-R6-C 112-00196 Cable,Ethernet,5m RJ45 CAT6,-C
X6562-R6-N-C 112-00196 Cable,Ethernet,5m RJ45 CAT6,-C
X6566B-05-N-C 112-00297 Cable,Direct Attach CU SFP+ 10G,0.5M,-C
X6566B-05-R6 112-00297 Cable,Direct Attach CU SFP+ 10G,0.5M
X6566B-05-R6-C 112-00297 Cable,Direct Attach CU SFP+ 10G,0.5M,-C
X6566B-2-N-C 112-00299 Cable,Direct Attach CU SFP+ 10G,2M,-C
X6566B-2-R6 112-00299 Cable,Direct Attach CU SFP+ 10G,2M
X6566B-2-R6-C 112-00299 Cable,Direct Attach CU SFP+ 10G,2M,-C
X6566B-3-N-C 112-00300 Cable,Direct Attach CU SFP+ 10G,3M,-C
X6566B-3-R6 112-00300 Cable,Direct Attach CU SFP+ 10G,3M
X6566B-3-R6-C 112-00300 Cable,Direct Attach CU SFP+ 10G,3M,-C
X6566B-5-N-C 112-00301 Cable,Direct Attach CU SFP+ 10G,5M,-C
X6566B-5-R6 112-00301 Cable,Direct Attach CU SFP+ 10G,5M
X6566B-5-R6-C 112-00301 Cable,Direct Attach CU SFP+ 10G,5M,-C
X6577-R6 112-00238 Cable,Ethernet,30m RJ45 CAT6
X6577-R6-C 112-00238 Cable,Ethernet,30m RJ45 CAT6,-C
X6577-R6-N-C 112-00238 Cable,Ethernet,30m RJ45 CAT6,-C
X6584-R6 112-00290 Cable,Ethernet,1m RJ45 CAT6
X6584-R6-C 112-00290 Cable,Ethernet,1m RJ45 CAT6,-C
X6584-R6-N-C 112-00290 Cable,Ethernet,1m RJ45 CAT6,-C
X6585-R6 112-00291 Cable,Ethernet,3m RJ45 CAT6
X6585-R6-C 112-00291 Cable,Ethernet,3m RJ45 CAT6,-C
X6585-R6-N-C 112-00291 Cable,Ethernet,3m RJ45 CAT6,-C
X6590-R6 112-00242 Cable,SAS Cntlr-Shelf/Shelf-Shelf,10m
X6591-R6 112-00243 Cable,SAS Cntlr-Shelf/Shelf-Shelf,20m
X6592-R6 112-00246 Cable,Ethernet,10m RJ45 CAT6
X6592-R6-N-C 112-00246 Cable,Ethernet,10m RJ45 CAT6,-C
X6593-R6 112-00247 Cable,Ethernet,20m RJ45 CAT6
X6593-R6-C 112-00247 Cable,Ethernet,20m RJ45 CAT6,-C
X6593-R6-N-C 112-00247 Cable,Ethernet,20m RJ45 CAT6,-C
X6594-R6 112-00256 Cable,SAS Cntlr-Shelf/Shelf-Shelf,HA,1m
X6594-R6-C 112-00256 Cable,SAS Cntlr-Shelf/Shelf-Shelf,HA,1m,-C
X6595-R6 112-00255 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,3m
X6595-R6-C 112-00255 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,3m,-C
X66000A-R6 112-00265 Cable,Storage,SAS-OM4,6G,QSFP,1m
X66000A-R6-C 112-00265 Cable,Storage,SAS-OM4,6G,QSFP,1m,-C
X66001A-R6 112-00266 Cable,Storage,SAS-OM4,6G,QSFP,2m
X66001A-R6-C 112-00266 Cable,Storage,SAS-OM4,6G,QSFP,2m,-C
X66002A-R6 112-00267 Cable,Storage,SAS-OM4,6G,QSFP,3m
X66002A-R6-C 112-00267 Cable,Storage,SAS-OM4,6G,QSFP,3m,-C
X66003A-R6 112-00268 Cable,Storage,SAS-OM4,6G,QSFP,5m
X66003A-R6-C 112-00268 Cable,Storage,SAS-OM4,6G,QSFP,5m,-C
X66004A-R6 112-00269 Cable,Storage,SAS-OM4,6G,QSFP,7m
X66005A-R6 112-00270 Cable,Storage,SAS-OM4,6G,QSFP,15m
X66006A-R6 112-00271 Cable,Storage,SAS-OM4,6G,QSFP,30m
X66007A-R6 112-00280 Cable,Storage,SAS-OM4,6G,QSFP,50m
X66008A-R6 112-00260 Cable,LT 150m-PatchP,OM4,6G,QSFP,LC,5m
X66008A-R6-C 112-00260 Cable,LT 150m-PatchP,OM4,6G,QSFP,LC,5m,-C
X66009A-R6 112-00261 Cable,LT 150m-PatchP,OM4,6G,QSFP,LC,30m
X66009A-R6-C 112-00261 Cable,LT 150m-PatchP,OM4,6G,QSFP,LC,30m,-C
X66010A-R6 112-00263 Cable,<150m-PatchP,OM4,6G,QSFP,SC,5m
X66011A-R6 112-00264 Cable,<150m-PatchP,OM4,6G,QSFP,SC,30m
X66012A-R6 112-00278 Cable,<150m-PatchP,OM4,6G,QSFP-MTRJ,5m
X66013A-R6 112-00279 Cable,<150m-PatchP,OM4,6G,QSFP-MTRJ,30m
X66014A-R6 112-00272 Cable,LT 500m-PatchP,OS1,6G,QSFP,LC,5m
X66014A-R6-C 112-00272 Cable,LT 500m-PatchP,OS1,6G,QSFP,LC,5m,-C
X66015A-R6 112-00273 Cable,LT 500m-PatchP,OS1,6G,QSFP,LC,30m
X66015A-R6-C 112-00273 Cable,LT 500m-PatchP,OS1,6G,QSFP,LC,30m,-C
X66016A-R6 112-00274 Cable,<500m-PatchP,OS1,6G,QSFP,SC,5m
X66017A-R6 112-00276 Cable,<500m-PatchP,OS1,6G,QSFP,SC,30m
X66018A-R6 112-00281 Cable,<500m-PatchP,OS1,6G,QSFP-MTRJ,5m
X66019A-R6 112-00282 Cable,<500m-PatchP,OS1,6G,QSFP-MTRJ,30m
X66020A-R6 112-00429 Cable,Storage,MiniSAS HD,QSFP,12G,1m
X66020A-R6-C 112-00429 Cable,Storage,MiniSAS HD,QSFP,12G,1m,-C
X66021A-R6 112-00430 Cable,Storage,MiniSAS HD,QSFP,12G,2m
X66021A-R6-C 112-00430 Cable,Storage,MiniSAS HD,QSFP,12G,2m,-C
X66022A-R6 112-00431 Cable,Storage,MiniSAS HD,QSFP,12G,5m
X66022A-R6-C 112-00431 Cable,Storage,MiniSAS HD,QSFP,12G,5m,-C
X66030A 112-00435 Cable,12Gb,Mini SAS HD,0.5m
X66030A-C 112-00435 Cable,12Gb,Mini SAS HD,0.5m,-C
X66030A-K-N 112-00435 Cable,12Gb,Mini SAS HD,0.5m
X66030A-N 112-00435 Cable,12Gb,Mini SAS HD,0.5m
X66030A-N-C 112-00435 Cable,12Gb,Mini SAS HD,0.5m,-C
X66031A 112-00436 Cable,12Gb,Mini SAS HD,1m
X66031A-C 112-00436 Cable,12Gb,Mini SAS HD,1m,-C
X66031A-K-N 112-00436 Cable,12Gb,Mini SAS HD,1m
X66031A-N 112-00436 Cable,12Gb,Mini SAS HD,1m
X66031A-N-C 112-00436 Cable,12Gb,Mini SAS HD,1m,-C
X66032A 112-00437 Cable,12Gb,Mini SAS HD,2m
X66032A-C 112-00437 Cable,12Gb,Mini SAS HD,2m,-C
X66032A-K-N 112-00437 Cable,12Gb,Mini SAS HD,2m
X66032A-N 112-00437 Cable,12Gb,Mini SAS HD,2m
X66032A-N-C 112-00437 Cable,12Gb,Mini SAS HD,2m,-C
X66033A 112-00438 Cable,12Gb,Mini SAS HD,3m
X66033A-C 112-00438 Cable,12Gb,Mini SAS HD,3m,-C
X66033A-K-N 112-00438 Cable,12Gb,Mini SAS HD,3m
X66033A-N 112-00438 Cable,12Gb,Mini SAS HD,3m
X66033A-N-C 112-00438 Cable,12Gb,Mini SAS HD,3m,-C
X66034A 112-00439 Cable,12Gb,Mini SAS HD,5m
X66034A-C 112-00439 Cable,12Gb,Mini SAS HD,5m,-C
X66034A-K-N 112-00439 Cable,12Gb,Mini SAS HD,5m
X66034A-N 112-00439 Cable,12Gb,Mini SAS HD,5m
X66034A-N-C 112-00439 Cable,12Gb,Mini SAS HD,5m,-C
X66040A 112-00449 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m
X66040A-C 112-00449 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m,-C
X66040A-K-N 112-00449 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m
X66040A-N 112-00449 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m
X66040A-N-C 112-00449 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m,-C
X66041A 112-00450 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m
X66041A-C 112-00450 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m,-C
X66041A-K-N 112-00450 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m
X66041A-N 112-00450 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m
X66041A-N-C 112-00450 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m,-C
X66042A 112-00451 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m
X66042A-C 112-00451 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m,-C
X66042A-K-N 112-00451 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m
X66042A-N 112-00451 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m
X66042A-N-C 112-00451 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m,-C
X66043A 112-00452 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m
X66043A-C 112-00452 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m,-C
X66043A-K-N 112-00452 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m
X66043A-N 112-00452 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m
X66043A-N-C 112-00452 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m,-C
X66044A 112-00453 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,15m
X66045A 112-00454 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,30m
X66046A 112-00455 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,50m
X66047A 112-00456 Cable,12Gb,SAS Opt,Mini SAS HD to LC,5m
X66047A-C 112-00456 Cable,12Gb,SAS Opt,Mini SAS HD to LC,5m,-C
X66047A-N-C 112-00456 Cable,12Gb,SAS Opt,Mini SAS HD to LC,5m,-C
X66048A 112-00457 Cable,12Gb,SAS Opt,Mini SAS HD to LC,30m
X66048A-C 112-00457 Cable,12Gb,SAS Opt,Mini SAS HD to LC,30m,-C
X66048A-N-C 112-00457 Cable,12Gb,SAS Opt,Mini SAS HD to LC,30m,-C
X66100-1 112-00542 Cable,Direct Attach CU QSFP,40Gb,1m
X66100-1-C 112-00542 Cable,Direct Attach CU QSFP,40Gb,1m,-C
X66100-1-K-N 112-00542 Cable,Direct Attach CU QSFP,40Gb,1m
X66100-1-N 112-00542 Cable,Direct Attach CU QSFP,40Gb,1m
X66100-1-N-C 112-00542 Cable,Direct Attach CU QSFP,40Gb,1m,-C
X66100-3 112-00543 Cable,Direct Attach CU QSFP,40Gb,3m
X66100-3-C 112-00543 Cable,Direct Attach CU QSFP,40Gb,3m,-C
X66100-3-K-N 112-00543 Cable,Direct Attach CU QSFP,40Gb,3m
X66100-3-N 112-00543 Cable,Direct Attach CU QSFP,40Gb,3m
X66100-3-N-C 112-00543 Cable,Direct Attach CU QSFP,40Gb,3m,-C
X66100-5 112-00544 Cable,Direct Attach CU QSFP,40Gb,5m
X66100-5-C 112-00544 Cable,Direct Attach CU QSFP,40Gb,5m,-C
X66100-5-K-N 112-00544 Cable,Direct Attach CU QSFP,40Gb,5m
X66100-5-N 112-00544 Cable,Direct Attach CU QSFP,40Gb,5m
X66100-5-N-C 112-00544 Cable,Direct Attach CU QSFP,40Gb,5m,-C
X66120-3 112-00545 Cable,Direct Attach CU 40G QSFP/4x10G SFP,3m
X66120-3-C 112-00545 Cable,Dir. Attach CU 40G QSFP/4x10G SFP,3m,-C

Supported Firmware Matrix - FAS8200 2-Node Stretch MetroCluster, Fiber Bridge

Major OS Version OS Version Firmeware
BIOS
ONTAP 9.11.1 9.11.1 11.15*
ONTAP 9.11.1 9.11.1RC1 11.16, 11.15*
ONTAP 9.10.1 9.10.1P5-P6 11.16, 11.15*
ONTAP 9.10.1 9.10.1P3-P4, 9.10.1P2, 9.10.1P1 11.16, 11.15, 11.13*
ONTAP 9.10.1 9.10.1, 9.10.1RC1 11.16, 11.15, 11.13, 11.11*
ONTAP 9.9.1 9.9.1P11, 9.9.1P10 11.16, 11.15*
ONTAP 9.9.1 9.9.1P8-P9, 9.9.1P7 11.16, 11.15, 11.13*
ONTAP 9.9.1 9.9.1P4-P6, 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 11.16, 11.15, 11.13, 11.11*
ONTAP 9.8 9.8P13 11.16, 11.15*
ONTAP 9.8 9.8P11-P12 11.16, 11.15, 11.13*
ONTAP 9.8 9.8P10, 9.8P9, 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4 11.16, 11.15, 11.13, 11.11*
ONTAP 9.8 9.8P3, 9.8P2, 9.8P1, 9.8, 9.8RC1 11.16, 11.15, 11.13, 11.11, 11.9*
ONTAP 9.7 9.7P19, 9.7P17-P18, 9.7P16, 9.7P15, 9.7P14 11.16, 11.15, 11.13, 11.11*
ONTAP 9.7 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8 11.16, 11.15, 11.13, 11.11, 11.9*
ONTAP 9.7 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7*
ONTAP 9.6 9.6P18, 9.6P17, 9.6P16, 9.6P15 11.16, 11.15, 11.13, 11.11*
ONTAP 9.6 9.6P13-P14, 9.6P12 11.16, 11.15, 11.13, 11.11, 11.9*
ONTAP 9.6 9.6P10-P11 11.16, 11.15, 11.13, 11.11, 11.9, 11.7*
ONTAP 9.6 9.6P9, 9.6P7-P8, 9.6P5-P6, 9.6P4, 9.6P3 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5*
ONTAP 9.6 9.6P2, 9.6, 9.6P1, 9.6RC2, 9.6RC1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5*
ONTAP 9.5 9.5P19, 9.5P18 11.16, 11.15, 11.13, 11.11*
ONTAP 9.5 9.5P17, 9.5P16, 9.5P15 11.16, 11.15, 11.13, 11.11, 11.9*
ONTAP 9.5 9.5P14 11.16, 11.15, 11.13, 11.11, 11.9, 11.7*
ONTAP 9.5 9.5P13, 9.5P12, 9.5P10-P11, 9.5P9, 9.5P8, 9.5P7, 9.5P6, 9.5P5, 9.5P4, 9.5P2-P3, 9.5P1, 9.5, 9.5RC1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4*
ONTAP 9.4 9.4P8, 9.4P7, 9.4P6, 9.4P5, 9.4P4, 9.4P3, 9.4P2, 9.4P1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4, 11.2.1*
ONTAP 9.4 9.4, 9.4RC1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4, 11.2.1, 11.2*
ONTAP 9.3 9.3P21 11.16, 11.15, 11.13, 11.11, 11.9*
ONTAP 9.3 9.3P20, 9.3P18-P19 11.16, 11.15, 11.13, 11.11, 11.9, 11.7*
ONTAP 9.3 9.3P16-P17, 9.3P15, 9.3P11-P14, 9.3P10, 9.3P7-P9, 9.3P1-P6, 9.3, 9.3RC1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4, 11.2.1, 11.2, 11.1*
ONTAP 9.2 9.2P2-P4, 9.2P1, 9.2, 9.2RC1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4, 11.2.1, 11.2, 11.1*
ONTAP 9.1 9.1P17-P20, 9.1P13-P16, 9.1P10-P12, 9.1P9, 9.1P8, 9.1P3-P7, 9.1P1-P2, 9.1, 9.1RC2, 9.1RC1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4, 11.2.1, 11.2, 11.1*, 11.0.2*
Footnote:
[1]* Indicates that firmware is bundled with Storage OS Version

Product Certificates - FAS8200 2-Node Stretch MetroCluster, Fiber Bridge

Certificate Name Geo / Region / Country Associated Products
Battery Pack safety reports
Lithium Battery Safety Doc-Section II/Section IB Shipments,Inventus Power Product Model#271-00046AWB Global Platforms : AFF A300, AFF A700, FAS8200, FAS9000
EMI and Safety certificates
Lithium Battery Safety Doc-Section II/Section IB Shipments,Inventus Power Product Model#271-00046AWB Global Platforms : AFF A300, AFF A700, FAS8200, FAS9000
Declaraion of Similarity NAF-1601 Global Platforms : AFF A300, FAS8200
NAF-1601 G-K-U-SoR Gabon,Kenya,SaudiArabia,Uganda Platforms : AFF A300, FAS8200
NAF-1601 (Jabil Mexico) BIS BIS - India Platforms : AFF A300, FAS8200
NAF-1601 (Jabil Singapore) BIS BIS - India Platforms : AFF A300, FAS8200
NAF-1601 60950-CB CB - International Platforms : AFF A300, FAS8200
NAF-1601 62368-CB-3rd_Edition CB - International Platforms : AFF A300, FAS8200
NAF-1601 ACMA ACMA - Australia, New Zealand Platforms : AFF A300, FAS8200
NAF-1601 BSMI BSMI - Taiwan Platforms : AFF A300, FAS8200
NAF-1601 CSA CSA - United States, Canada Platforms : AFF A300, FAS8200
NAF-1601 CE DoC CE - European Union DoC Platforms : AFF A300, FAS8200
NAF-1601 EAC EAC - Armenia, Belarus, Kazakhstan, Kyrgyzstan, Russia Platforms : AFF A300, FAS8200
NAF-1601 FCC FCC - United States Platforms : AFF A300, FAS8200
NAF-1601 IRAM IRAM - Argentina Platforms : AFF A300, FAS8200
NAF-1601 KC KC - South Korea Platforms : AFF A300, FAS8200
NAF-1601 Morocco Morocco Platforms : AFF A300, FAS8200
NAF-1601 NOM NOM - Mexico Platforms : AFF A300, FAS8200
NAF-1601 NRCS NRCS - South Africa (Safety) Platforms : AFF A300, FAS8200
NAF-1601 SONCAP SONCAP - Nigeria Platforms : AFF A300, FAS8200
NAF-1601 TBS TBS - Tanzania Platforms : AFF A300, FAS8200
NAF-1601 UKRSepro UKRSepro - Ukraine Platforms : AFF A300, FAS8200
NAF-1601 VCCI VCCI - Japan Platforms : AFF A300, FAS8200
NAF-1601 UKCA DOC UKCA -United Kingdom Platforms : AFF A300, FAS8200
NAF-1601 62368-CB-2nd_Edition CB - International Platforms : AFF A300, FAS8200
PSU 80+ Platinum Certificates
NAF-1601 62368-CB-2nd_Edition CB - International Platforms : AFF A300, FAS8200
DCJ14602-01 Energy Star Report Global
PSU : X5729A
Voluntary Product Accessibility Template
DCJ14602-01 Energy Star Report Global
PSU : X5729A

Size, Weight, Acoustic, Power FAS8200 2-Node Stretch MetroCluster, Fiber Bridge

Associated Part No. Configuration Rack Units Weight Sound Power Sound Pressure Line Voltage Actual (Min to Max) Amps Typical Amps Worst Watts Typical Watts Worst BTU / Hr Typical BTU / Hr Worst
FAS8200
FAS8200A FAS8200 2 PCM 3 76.0 lb (34.5 kg) 6.9 Bels 53.1 dBA 100 (100 to 120) 5.65 6.49 553 636 1888 2171
FAS8200A FAS8200 2 PCM 3 76.0 lb (34.5 kg) 6.9 Bels 53.1 dBA 200 (200 to 240) 2.77 3.19 542 624 1850 2130

 

Shipping Information

Express Computer Systems can ship to virtually any address in the world and provides you with the best shipping rates possible. Cost of shipping varies depending on what service you require, your destination and size of the shipment. Shipping costs will be calculated separately from your order and billed to you post purchase. In the notes section of your order please provide us with your preferred shipping method and we will get back to you.

Custom configured orders ship within 2 business days after all required products are in stock.

Please allow 3 business days for products that are not in stock to arrive to our facility in Irvine, California.

Domestic Shipments
  • Standard Ground
    • Shipping time: 2-7 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-10 business days
    • Excludes weekends, holidays or weather delays.
  • 3 Business Days
    • Shipping time: 3 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 3-6 business days
    • Excludes weekends, holidays or weather delays.
  • 2 Business Days
    • Shipping time: 2 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-5 business days
    • Excludes weekends, holidays or weather delays.
  • Overnight / Next Business Day
    • Shipping time: 1 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 1-4 business days
    • Excludes weekends, holidays or weather delays.
International Shipments
  • International Economy
    • Shipping time: 4-6 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 5-9 business days
    • Excludes weekends, holidays or weather delays.
  • International Priority
    • Shipping time: 1-3 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-6 business days
    • Excludes weekends, holidays or weather delays.

For more information on shipping view our Shipping Information page or send us a message

ECS Warranty Information

Express Computer Systems (ECS) provides a 1 year parts warranty against defects in material or workmanship that will affect the products functionality. All refurbished items are tested prior to shipping to guarantee up-time upon arrival. If you are having issues with an item we provided please Contact Us and we will do our best to assist you.

What does our ECS warranty cover?
We offer 1 year warranty as standard and additional years can be added to fit your needs. Please reach out to a sales associate via the Contact Us page or live chat for more information on extended coverage options. During the coverage period if your product fails we will offer a Next Business Day replacement. If we are unable to replace the product we will refund its original selling price. Shipping costs and tax are not refundable. Express Computer Systems retains the right to decide whether the goods will be replaced or refunded.

What is not covered by our warranty?
Our warranty does not cover any problem caused by the following conditions:

  1. accidents; misuse; carelessness; electrostatic discharge; shock; temperature or humidity beyond the specifications of the product; improper installation; operation; modification;
  2. any improper use that contravenes the instructions in the user manual;
  3. problems caused by other equipment. Our warranty is void if the product is returned with damaged, removed, counterfeit labels, or any modifications (including any component or external cover removal). Our warranties do not cover data loss or damages to any other equipment. In addition, our warranties do not cover incidental damages, consequential damages, or costs related to data recovery, removal, and installation.

Important notes:

  • Please ask for additional warranty/coverage that you may require in addition to the standard 1 ECS warranty prior to final purchase. Requesting additional warranty after your purchase can be denied.
  • FREE technical support is provided on purchased items via phone, email, or live chat.

About Express Computer Systems

Express Computer Systems is committed to transforming our customers’ IT infrastructure with high quality products at affordable costs. Our sales reps and customer support engineers understand our customers rely heavily on advanced technology to run their business but need to do so without breaking the bank.

We specialize in building custom server configurations, custom storage solutions, networking solutions, and components from top manufacturers including HPE, Dell, Cisco, NetApp, Dell EMC, HPE Nimble and many others.

Subscribe