Please remove $0 item(s) from cart - or - Request for Quote

NetApp FAS2720 2-port UTA2 Single Chassis HA Pair Filer Head (FAS2720-UTA2-2P-1C)

 
Price: Request a Quote

Brand:  
MPN:  
FAS2720-UTA2-2P-1C
Type:  
Filer Head
Condition:  
ECS Refurbished & Tested

Request Quote

Note: Please include as much details and relevant options about the item to help us match your request with an accurate price.


-PLEASE CONTACT FOR CUSTOM CONFIGURATIONS. DISK SHELVES, COMPLETE CONFIGURATIONS & TURN KEY SYSTEMS AVAILABLE.
-SPARE PARTS AVAILABLE FOR EACH MODEL. PLEASE ASK FOR PRICING ON SPARE DISK, CONTROLLERS, POWER SUPPLIES, NICs, HBAs, SFPs, Cables, etc.

NetApp FAS2720 2-port UTA2 Single Chassis HA Pair Filer Head (FAS2720-UTA2-2P-1C)

Powered by NetApp® ONTAP® data management software, we can help you build a storage infrastructure that is simple, secure, and trusted. NetApp FAS Storage Arrays provides customers with a balance of performance and capacity.

NetApp FAS2720 specs

Perfectly suited to high-capacity use cases within small and midsized enterprises. Easy setup and operations are also standard.

  • Maximum raw capacity per HA pair: 1440TB
  • Maximum drives per HA pair: 144
  • NAS scale-out: 1-24 nodes (12 HA pairs)
  • SAN scale-out: 1-12 nodes (6HA pairs)
  • Maximum raw capacity for cluster: 17PB
  • Controller chassis from factor: 2U / 12 internal drives
  • OS version: ONTAP 9.4 RC1 and later
  • Storage protocols supported: FC, FCoE, iSCSI, NFS, pNFS, CIFS/SMB

Flexibly adapt to evolving business needs
Provision storage in minutes.
Go from initial power-on to serving data in less than 10 minutes with provisioning for key business applications.

Simplify ongoing management.
Upgrade software or service storage during regular business hours with zero downtime.

Streamline operations.
Leverage one unified system for SAN and NAS with proven storage efficiency.

Secure and protect your data across your hybrid cloud
On-premise & public clouds, we have you covered
Start small and scale nondisruptively as your data requirements grow, on premises and in the cloud.

The Best Cloud Integration
Connect effortlessly to the cloud with leading integration to Amazon AWS, Microsoft Azure, Google Cloud, and others.

Prevent problems before they affect your business
Optimize your storage environment and reduce costs with the predictive analytics and proactive care of NetApp ® Active IQ® .

Customer proven for diverse workloads
Secure your sensitive information
Protect your data at rest and in transit with our portfolio of security capabilities.

Safeguard against data loss
Efficiently replicate data and accelerate recovery with application-consistent data protection.

Eliminate business disruptions
Maintain access to data at all times during service, failures, and site disasters.

Customer proven, real-world results
IDC Whitepaper validates NetApp customers achieve six-nines availability.

Product Specs

Storage Limits

Max # of Drives (Total) Max # of Internal Drives Max # of NL-SAS Drives Max # of SAS Drives Max # of SATA Drives Max # of SSD Drives Max # of DS212C Shelves Max # of DS2246 Shelves Max # of DS224C Shelves Max # of DS4243 Shelves Max # of DS4246 Shelves Max # of DS460C Shelves
144 12 144 144 144 136 1 internal + 9 external 6 external 6 external 6 external 6 external 2 external

Capacity Limits

Marketing Maximum Raw Capacity - Node HA Pair Cluster Effective Capacity - Node HA Pair Cluster
2304000 2304000 Detailed Matrix 10226304 10226304

Core Cluster Limits

Max SVM's - NAS - Node / HA Pair / Cluster Max LIF's - NAS - Node / HA Pair / Cluster Max Connections - NAS - Node / HA Pair(Non-Scalable) Max Flexible Volumes - NAS - Aggregate (Single data Agg. per Node) / Aggregate (Multiple data Agg. per Node) / Node/ HA Pair / Cluster Max Flexible Volumes with DPO - NAS - Node/ HA Pair / Cluster Max Lock Manager Locked Objects - Node/HA Pair/Cluster Max Intercluster LIFs - Node Min Root Aggregate (MiB) - Node Min Root Volume (GiB) - Node Max IPsec Policies - SVM / Cluster Max Auditing-Enabled SVMs - Cluster
/ / 512 512 / 512 / 3072 100000 / 100000 / / 1000 / 2000 / 15000 1500 / 3000 / 12000 1200000 / 1200000 / 12288000 8 191488 150 256 / 1500 50

System Maximums and Limits

Max Nodes per Cluster (NAS / SAN) Max FabricPool Size Max Infinite Volume Data Constituent Size Max FlexGroup Data Constituent Size Min Root Volume Size NetApp Volume Encryption
Not Supported / Not Supported 8400 TiB Not Supported 150 GiB  [1] Supported

Processor

Processor Model Processor Architecture Processor Speed Processor Count (Per Node) Processor Count (Per Config) Processor Cores (Per CPU) Processor Cores (Per Node) Processor Cores (Per Config)
64-bit 12-core 1.50 Ghz 64 bit 1.50 Ghz 1 2 12 12 24

Memory

Detailed Memory Matrix NVME (Per Node) NVME (Per Config) NVMEM (Per Node) NVMEM (Per Config) RAM (Per Node) RAM (Per Config)
Platform Memory Specifications 1024 GB 2048 GB 4 GB 8 GB 32 GB 64 GB

Onboard Ports

Full Onboard Ports Matrix Ethernet Ports Fibre Channel Ports UTA2 Ports Expansion Slots SAS Ports
Onboard Ports & Cables 4 x SFP+ (10Gb) - - 4 x MiniSAS HD (12Gb)

Physical Characteristics

Rack Units Chassis Height Chassis Width with Mounting Flanges Chassis Width without Mounting Flanges Chassis Depth with Cable Mgmt Chassis Depth without Cable Mgmt Chassis Weight
2 3.42" (8.69 cm) 18.9" (48 cm) 17.6" (44.7 cm) 25.12" (63.8 cm) 20" (50.8 cm) See Weights by configuration

System Clearance Dimensions

Front Clearance (Cooling) Front Clearance (Maintenance) Rear Clearance (Cooling) Rear Clearance (Maintenance)
6.03" (15.3 cm) 24.03" (61 cm) 6.03" (15.3 cm) 13" (33 cm)

Environmental Requirements

Operating Temp / Humidity / Altitude Storage Temp / Humidity / Altitude Transit Temp / Humidity / Altitude Acoustic Noise - Sound Power / Pressure Input Power Voltage
41 to 113 deg F - 5 to 45 deg C / 8 to 90 % / Up to 10000.0 ft - Up to 3048.0 m -40 to 158 deg F - -40 to 70 deg C / 10 to 95 % / Up to 40000.0 ft - Up to 12192.0 m -40 to 158 deg F - -40 to 70 deg C / 10 to 95 % / Up to 39989.8 ft - Up to 12192 m 6.7 bels / 51 dBA 100 to 120

Storage OS Requirements

Full OS Matrix Recommended Version Minimum OS Maximum OS
View Full OS Report Below 9.11.1 9.11.1RC1 9.11.1

Storage and Firmware

Full Firmware Matrix BIOS BMC
Full Firmware ReportBelow 11.15* 11.8*

Product Standards Compliance

Full Compliance and Certificates Report Cert. EMC/EMI Cert. Safety Cert. Safety/EMC/EMI Cert. Safety/EMC/EMI/RoHS Standard Safety/EMC/EMI Standard Safety
Compliance and Certificates ReportBelow AMCA, FCC, ICES, KC, Morocco, VCCI BIS, CB, CSA, G_K_U-SoR, IRAM, NOM, NRCS, SONCAP, TBS EAC, UKRSEPRO BSMI, CE DoC, UKCA DoC BS-EN-55024, BS-EN55035, CISPR 32, EN55022, EN55024, EN55032, EN55035, EN61000-3-2, EN61000-3-3, FCC Part 15 Class A, IC  more... ANSI/UL60950-1, ANSI/UL62368-1, BS-EN62368-1, CAN/CSA C22.2 No. 60950-1, CAN/CSA C22.2 No. 62368-1, CNS 14336, EN60825-1  more...

NFS Cluster Limits

Max Export Policies Max Export Rules Max NFSv4 Access Control Entries Max Client Objects - Node / HA Pair Max pNFS objects - Node / HA Pair
24000 200000 1024 10000 / 10000 524288 / 524288 / 1048576

WAFL Cluster Limits - All Maximums

Size 64-bit Aggregate (TiB) Size 64-bit Volume (TiB) File size 64-bit Volume (TiB) Snapshot - Volume / Node / HA Pair Char's Snapshot Hard links - File inodes/files - Volume qtrees - Volume / Node / HA Pair / Cluster Concurrent DataMotion for Volumes ops - Node / HA Pair
800 100 16 1023 / 1023000 / 2046000 255 100000 2000000000 4995 / 100000 / 200000 / 400000 16 / 16

Quality of Service Cluster Limits

Max Policy Groups - Cluster Max QoS User Workloads - Cluster
12000 40000

SAN Cluster Limits - All Maximums

SVMs - Node / HA Pair / Cluster Flexible Vol - Node / HA Pair / Cluster Flexible Vol with DPO - Node / HA Pair / Cluster LUNs Vol - Node / HA Pair / Cluster LUN mappings - Node / HA Pair / Cluster LUN size (TiB) - LUN Maximum FC queue depth available SAN Hosts (ITNs) - Port / Node / HA Pair / Cluster LIFS - iSCSI - Port / Portset / Node / HA Pair / Cluster LIFS - FCP - Port / Portset / Node / HA Pair / Cluster igroups - Node / HA Pair / Cluster Initiators - igroup / Node / HA Pair / Cluster Portsets - Node / HA Pair / Cluster iSCSI sessions - Node / HA Pair / Cluster
125 / 250 / 1000 / / 1000 / 2000 / 12000 1500 / 3000 / 12000 1024 / 8192 / 16384 / 65536 8192 / 16384 / 65536 16 2048 512 / 4096 / 8192 / 32768 32 / 32 / 512 / 1024 / 4096 32 / 32 / 512 / 1024 / 4096 2048 / 4096 / 16384 256 / 2048 / 4096 / 16384 2048 / 4096 / 16384 4096 / 8192 / 32768

CIFS Cluster Limits - All Maximums

Connected shares - Node / HA Pair Regular shares - Node / HA Pair / Cluster Open files - Connection / Node / HA Pair Local users - Cluster Local groups - Cluster Local group members - Cluster
Detailed Matrix / 800000 N/A / N/A / 60000 600000 / 600000 / 600000 5000 10000 30000

Data Protection Cluster Limits - All Maximums

NDMP Sessions - Node / HA Pair (Non-Scalable) Data Protection Mirrors - Volume / Node / HA Pair / Cluster Load Sharing Mirrors - NAS SVM Concurrent Snap Mirror / SnapVault transfers - Node DP Mirror fan-out - Volume LS Mirror fan-out - NAS SVM Clusters that can be peered - Cluster Volumes, SnapMirror relationship - FlexGroup / FlexGroup-Node /HA Pair / Cluster SnapMirror Synchronous relationships - Volume / Node / HA Pair (Non-Scalable) Flexible Volumes in SVM DR - SVM / HA Pair SVM Disaster recovery - Cluster
36 / 36 1 / 1000 / 2000 / 15000 2 100 8 2 255 200 / 50 / 1000 / 6000 1 / 20 / 20 300 / 1000 128

NVMe/oF Cluster Limits - All Maximums

Storage virtual machines (SVMs), NVMe/oF - Cluster Flexible volumes, NVMe/oF - Node / HA Pair / Cluster Flexible volumes with DPO, NVMe/oF - Node / HA Pair / Cluster Namespaces - Volume / Node / HA Pair / Cluster Subsystems - SVM / Cluster Namespace Mappings - Subsystem / Node / HA Pair / Cluster Namespace Size Hosts - Subsystem LIFS, NVMe/oF - Port / SVM / Node / HA Pair / Cluster I/O Queue Count, NVMe/TCP - Controller I/O Queue Depth - NVMe/TCP Controllers, NVMe/TCP - Node
32 1000 / 2000 / 12000 1500 / 3000 / 12000 1024 / 8192 / 16384 / 65536 512 / 512 1024 / 8192 / 16384 / 65536 16 64 16 / 8 / 32 / 32 / 32 2 128 1024

FlexCache Cluster Limits - All Maximums Cache

Degree of fan-out - Origin Origin Volumes - Node / HA Pair Constituent Volumes - Node / HA Pair Volumes - Node / HA Pair Origin ConstituentVolumes - Node / HA Pair
100 100 / 200 800 / 1600 100 / 200 800 / 1600

S3 Cluster Limits - All Maximums

Number of Buckets - Vserver / Cluster Number of Objects - Bucket Number of Users - Vserver / Cluster Size of the Bucket (PB) - Vserver
12000 / 12000 400000000000 4000 / 96000 20

Consistency Groups - All Maximums

Number of Consistency Groups - Cluster Number of Parent Consistency Groups - Cluster Consistency Groups and Parents - Cluster Child Consistency Groups in a Parent - Parent Group Flexible Volumes in a Consistency Group Flexible Volumes for Child Consistency Groups under a Parent Group Flexible Volumes in a Child Consistency Group
15000 15000 15000 5 80 80

Platform LED for FAS2720 2-Port UTA2 Single Chassis HA Pair

LED Label LED Name Type Status Indicator Description
Front View
1 Chassis Power Config - On Green At least one of the two PSUs is delivering power to the system.
- - - Off Neither PSU is delivering power to the system.
2 Chassis Attention LED, front - On Amber The system halted or a fault occurred in the chassis.
- - - Off The system is operating normally.
3 Location LED on chassis front - On or flashing blue The LED has been manually activated to aid in physically locating equipment
- - - Off The LED has not been manually activated to aid in physically locating equipment
4 Shelf ID Digital Display - Number Displayed Digital Shelf ID
Back View
LED Label LED Name Type Status Indicator Description
0a Port SAS 2 LED Onboard Config Attention Yellow SAS link requires attention
- - - Off SAS link operates as normal
- - Link Green Link is established on at least one external SAS lane
- - - Off No link is established on any external SAS lane
0b Port SAS 2 LED Onboard Config Attention Yellow SAS link requires attention
- - - Off SAS link operates as normal
- - Link Green Link is established on at least one external SAS lane
- - - Off No link is established on any external SAS lane
e0a Port Ethernet SFP Config Attention Yellow Ethernet Port requires attention.
- - - Off Ethernet port operates as normal
- - Link Green A connection is established to the port.
- - - Off No connection is established on the port.
e0b Port Ethernet SFP Config Attention Yellow Ethernet Port requires attention.
- - - Off Ethernet port operates as normal
- - Link Green A connection is established to the port.
- - - Off No connection is established on the port.
e0c/0c Port UTA2 Config (Ethernet personality) Attention Off Port is operating as normal
- - Link Green A connection is established to the port.
- - - Yellow Port requires attention
- - - Off No connection is established on the port.
e0c/0c Port UTA2 Config (FC personality) Attention Off Port is operating as normal
- - Link Green A connection is established to the port.
- - - Yellow Port requires attention
- - - Off No connection is established on the port.
e0d/0d Port UTA2 Config (Ethernet personality) Attention Off Port is operating as normal
- - Link Green A connection is established to the port.
- - - Yellow Port requires attention
- - - Off No connection is established on the port.
e0d/0d Port UTA2 Config (FC personality) Attention Off Port is operating as normal
- - Link Green A connection is established to the port.
- - - Yellow Port requires attention
- - - Off No connection is established on the port.
e0m/BMC Ethernet On/Off Port Activity Blinking green Traffic is present on the active link
- - - Off Off
- - Port Link Solid green On
- - Link Green A connection is established to the port.
- - - Yellow Port requires attention
- - - Off No connection is established on the port.
e0f/0f Port UTA2 Config (Ethernet personality) Attention Off Port is operating as normal
- - Link Green A connection is established to the port.
- - - Yellow Port requires attention
- - - Off No connection is established on the port.
e0f/0f Port UTA2 Config (FC personality) Attention Off Port is operating as normal
- - Link Green A connection is established to the port.
- - - Yellow Port requires attention
- - - Off No connection is established on the port.
e0m/BMC Ethernet On/Off Port Activity Blinking green Traffic is present on the active link
- - - Off Off
- - Port Link Solid green On

Supported Shelves Drives for FAS2720 2-Port UTA2 Single Chassis HA Pair

Part No.Capacity RPM Drive Type Encryption Root-Data Partitioning Root-Data-Data Partitioning Storage Pool Partitioning Max Drive Count FlexArray
FAS2720A 2-port UTA2 Internal Drives
X302A-R5 1TB 7.2K SATA No Yes No No 12 No
X306A-R5 2TB 7.2K SATA No Yes No No 12 No
X308A-R5 3TB 7.2K SATA No Yes No No 12 No
X315A-R6 [1] [2] 4TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 12 No
X318A-R6 8TB 7.2K NL-SAS No Yes No No 12 No
X322A [1] 10TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 12 No
X336A-R6 4TB 7.2K NL-SAS No Yes No No 12 No
X339A 2TB 7.2K NL-SAS No Yes No No 12 No
X363A-R6 3.84TB N/A SSD No No No Yes 4 No
X364A 3.84TB N/A SSD No No No Yes 4 No
X366A-R6 [1] 1.6TB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 4 No
X374A 960GB N/A SSD No No No Yes 4 No
X380A 10TB 7.2K NL-SAS No Yes No No 12 No
X388A 16TB 7.2K NL-SAS No Yes No No 12 No
X448A-R6 200GB N/A SSD No No No Yes 4 No
X449A-R6 800GB N/A SSD No No No Yes 4 No
X477A-R6 4TB 7.2K NL-SAS No Yes No No 12 No
X488A-R5 900GB 10K SAS No Yes No No 12 No
X489A-R6 1.2TB 10K SAS No Yes No No 12 No
X490A-R6 1.8TB 10K SAS No Yes No No 12 No
X575A-R6 400GB N/A SSD No No No Yes 4 No
X576A-R6 1.6TB N/A SSD No No No Yes 4 No
X577A-R6 [1] 800GB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 4 No
DS212C with IOM12 / IOM12B / IOM12 / IOM12B shelf modules
X302A-R5 1TB 7.2K SATA No Yes No No 108 No
X306A-R5 2TB 7.2K SATA No Yes No No 108 No
X308A-R5 3TB 7.2K SATA No Yes No No 108 No
X315A-R6 [1] [2] 4TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 108 No
X317A [1] 6TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 108 No
X318A-R6 8TB 7.2K NL-SAS No Yes No No 108 No
X322A [1] 10TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 108 No
X336A-R6 4TB 7.2K NL-SAS No Yes No No 108 No
X339A 2TB 7.2K NL-SAS No Yes No No 108 No
X363A-R6 3.84TB N/A SSD No No No Yes 108 No
X364A 3.84TB N/A SSD No No No Yes 108 No
X366A-R6 [1] 1.6TB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 108 No
X374A 960GB N/A SSD No No No Yes 108 No
X380A 10TB 7.2K NL-SAS No Yes No No 108 No
X388A 16TB 7.2K NL-SAS No Yes No No 108 No
X448A-R6 200GB N/A SSD No No No Yes 108 No
X449A-R6 800GB N/A SSD No No No Yes 108 No
X477A-R6 4TB 7.2K NL-SAS No Yes No No 108 No
X488A-R5 900GB 10K SAS No Yes No No 108 No
X489A-R6 1.2TB 10K SAS No Yes No No 108 No
X490A-R6 1.8TB 10K SAS No Yes No No 108 No
X575A-R6 400GB N/A SSD No No No Yes 108 No
X576A-R6 1.6TB N/A SSD No No No Yes 108 No
X577A-R6 [1] 800GB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 108 No
DS224C with IOM12B / IOM12B / IOM12 / IOM12 shelf modules
X319A 7.6TB N/A SSD No No No No 132 No
X341A-R6 900GB 10K SAS No Yes No No 132 No
X342A-R6 1.2TB 10K SAS No Yes No No 132 No
X343A-R6 1.8TB 10K SAS No Yes No No 132 No
X356A-R6 3.84TB N/A SSD No No No Yes 132 No
X357A 3.84TB N/A SSD No No No Yes 132 No
X358A [1] 3.84TB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 132 No
X365A-R6 [1] 1.6TB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 132 No
X371A 960GB N/A SSD No No No Yes 132 No
X386A [1] 960GB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 132 No
X417A-R6 [1] [2] 900GB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 132 No
X422A-R5 600GB 10K SAS No Yes No No 132 No
X423A-R5 900GB 10K SAS No Yes No No 132 No
X425A-R6 1.2TB 10K SAS No Yes No No 132 No
X426A-R6 1.8TB 10K SAS No Yes No No 132 No
X427A [1] 1.8TB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 132 No
X427B-R6 [1] 1.8TB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 132 No
X438A-R6 400GB N/A SSD No No No Yes 132 No
X439A-R6 1.6TB N/A SSD No No No Yes 132 No
X440B-R6 [1] 800GB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 132 No
X446B-R6 200GB N/A SSD No No No Yes 132 No
X447A-R6 800GB N/A SSD No No No Yes 132 No
X670A 15.3TB N/A SSD No No No No 132 No
DS460C with IOM12 / IOM12B / IOM12 / IOM12B shelf modules
X379A 960GB N/A SSD No No No Yes 20 No
X375A 4TB 7.2K NL-SAS No Yes No No 120 No
X376A 8TB 7.2K NL-SAS No Yes No No 120 No
X377A 10TB 7.2K NL-SAS No Yes No No 120 No
X378A [1] 10TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X387A 16TB 7.2K NL-SAS No Yes No No 120 No
DS2246 with IOM6 / IOM12 / IOM12 / IOM6 / IOM12B / IOM12B shelf modules
X341A-R6 900GB 10K SAS No Yes No No 132 No
X342A-R6 1.2TB 10K SAS No Yes No No 132 No
X343A-R6 1.8TB 10K SAS No Yes No No 132 No
X356A-R6 3.84TB N/A SSD No No No Yes 120 No
X357A 3.84TB N/A SSD No No No Yes 132 No
X358A [1] 3.84TB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 132 No
X365A-R6 [1] 1.6TB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 132 No
X371A 960GB N/A SSD No No No Yes 132 No
X416A-R5 [1] 600GB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 132 No
X417A-R6 [1] [2] 900GB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 132 No
X421A-R5 450GB 10K SAS No Yes No No 132 No
X422A-R5 600GB 10K SAS No Yes No No 132 No
X423A-R5 900GB 10K SAS No Yes No No 132 No
X425A-R6 1.2TB 10K SAS No Yes No No 132 No
X426A-R6 1.8TB 10K SAS No Yes No No 132 No
X427A [1] 1.8TB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 132 No
X427B-R6 [1] 1.8TB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 132 No
X438A-R6 400GB N/A SSD No No No Yes 132 No
X439A-R6 1.6TB N/A SSD No No No Yes 132 No
X440A-R6 [1] 800GB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 132 No
X440B-R6 [1] 800GB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 132 No
X446B-R6 200GB N/A SSD No No No Yes 132 No
X447A-R6 800GB N/A SSD No No No Yes 132 No
DS4246 with IOM12 / IOM12 / IOM12B / IOM6 / IOM6 / IOM12B shelf modules
X302A-R5 1TB 7.2K SATA No Yes No No 132 No
X306A-R5 2TB 7.2K SATA No Yes No No 132 No
X308A-R5 3TB 7.2K SATA No Yes No No 132 No
X309A-R6 [1] [2] 3TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 132 No
X315A-R6 [1] [2] 4TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 132 No
X316A-R6 6TB 7.2K NL-SAS No Yes No No 132 No
X317A [1] 6TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 132 No
X318A-R6 8TB 7.2K NL-SAS No Yes No No 132 No
X322A [1] 10TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 132 No
X336A-R6 4TB 7.2K NL-SAS No Yes No No 132 No
X363A-R6 3.84TB N/A SSD No No No Yes 132 No
X366A-R6 [1] 1.6TB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 132 No
X374A 960GB N/A SSD No No No Yes 132 No
X380A 10TB 7.2K NL-SAS No Yes No No 132 No
X441A-R5 100GB N/A SSD No No No No 132 No
X448A-R6 200GB N/A SSD No No No Yes 132 No
X449A-R6 800GB N/A SSD No No No Yes 132 No
X477A-R6 4TB 7.2K NL-SAS No Yes No No 132 No
X488A-R5 900GB 10K SAS No Yes No No 132 No
X489A-R6 1.2TB 10K SAS No Yes No No 132 No
X490A-R6 1.8TB 10K SAS No Yes No No 132 No
X575A-R6 400GB N/A SSD No No No Yes 132 No
X576A-R6 1.6TB N/A SSD No No No Yes 132 No
DS4243 [3] with IOM12 / IOM6 shelf modules
X302A-R5 1TB 7.2K SATA No No No No 132 No
X306A-R5 2TB 7.2K SATA No No No No 132 No
X308A-R5 3TB 7.2K SATA No No No No 132 No
Footnote:
[1] Mixing NSE drives or shelves with any other type of encrypting or non-encrypting drives or shelves across a stand-alone platform or high-availability (HA) pair is not supported.
[2] In Flash Pool NSE SSD drives can only be used with NSE HDD drives.
[3] The DS4243 shelf requires an upgrade to IOM6 or IOM12 Expander Modules starting with ONTAP 9.4RC1 and FAS27x0.

Supported RAID Configurations - FAS2720 2-Port UTA2 Single Chassis HA Pair

Drive Type Drive Capacity Min Drive Capacity Max Minimum Default Maximum
Data Aggregate
RAID4
NL-SAS 0 TB 8 TB 3 7 7
SAS 0 TB 5.999 TB 3 8 14
SATA 0 TB 5.999 TB 3 7 7
SSD 0 TB 15.3 TB 3 8 14
RAID-DP
NL-SAS 0 TB 5.999 TB 5 14 20
NL-SAS 6 TB 10 TB 5 14 14
SAS 0 TB 5.999 TB 5 16 28
SATA 0 TB 5.999 TB 5 14 20
SSD 0 TB 15.3 TB 5 24 28
RAID-TEC
NL-SAS 0 TB 16 TB 7 21 29
SAS 0 TB 8 TB 7 24 29
SATA 0 TB 8 TB 7 21 29
SSD 0 TB 15.3 TB 7 25 29
Root Aggregate
RAID-DP
NL-SAS 0 TB 5.999 TB 3 20
NL-SAS 6 TB 16 TB 3[1] 14
SAS 0 TB 5.999 TB 3[2] 28
SATA 0 TB 5.999 TB 3[2] 20
SSD 0 TB 15.3 TB 3 28
RAID-TEC
NL-SAS 0 TB 16 TB 7 29
SAS 0 TB 8 TB 7 29
SATA 0 TB 8 TB 7 29
SSD 0 TB 15.3 TB 7 29
Footnote:
1RAID-DP is supported with 10TB NL-SAS drives only if HA pair has 10-14 drives
2The minimum number of disks in a RAID-DP group is three: at least one data disk, one regular parity disk, and one double-parity (dParity) disk. However, for non-root aggregates with only one RAID group, you must have at least 5 disks (three data disks and two parity disks).

Supported Adapter Cards - FAS2720 2-Port UTA2 Single Chassis HA Pair

Priority Category Bus Type Mktg Part No. Mfg Part No Description Plug Type Optical Module Included? Cables Supported Protocol(s) Min ONTAP Max Qty [1] Priority Slot Assignment
1 Performance Acceleration M.2 PCIe X3311A - 111-03066 Flash Cache,1.0TB,NVMe No N/A 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
Footnote:
[1] Values shown for max quantity are per controller.  HA configurations will support 2x the values shown.

Supported Connections for FAS2720 2-Port UTA2 Single Chassis HA Pair

Configuration Type Port Configuration Image Cluster Ports per Node Switch Ports per Node
Cluster Interconnect
2-node Switchless Cluster (option 1) Default View Image Above 2 None
2-node Switchless Cluster (option 2) UTA2 ports e0c/e0d View Image Above 2 None
2-node Switchless Cluster (option 3) UTA2 ports e0e/e0f View Image Above 2 None
Switched 10GbE Interconnect Default, Recommended View Image Above 2 2
Switched 40GbE Interconnect (10GbE breakout) Default, Recommended View Image Above 2 1

Platform Mixing Rules - FAS2720 2-Port UTA2 Single Chassis HA Pair

Platform Configuration Type Maximum Nodes (NAS) [1] Maximum Nodes (SAN) [1] Min ONTAP Version for Platform Mixing
FAS - Current Configuration(s)
FAS2720A 10GBASE-T 24 Nodes 12 Nodes 9.4RC1
FAS2720A UTA2 24 Nodes 12 Nodes 9.4RC1
FAS2750A 10GBASE-T 24 Nodes 12 Nodes 9.4RC1
FAS2750A UTA2 24 Nodes 12 Nodes 9.4RC1
FAS500fA 24 Nodes 12 Nodes 9.8RC1
FAS8300A Ethernet Bundle 24 Nodes 12 Nodes 9.7RC1
FAS8300A FC Bundle 24 Nodes 12 Nodes 9.7RC1
FAS8700A Ethernet Bundle 24 Nodes 12 Nodes 9.7RC1
FAS8700A FC Bundle 24 Nodes 12 Nodes 9.7RC1
FAS9000A 24 Nodes 12 Nodes 9.4RC1
FAS9500A 24 Nodes 12 Nodes 9.10.1P3
AllFlashFAS - Current Configuration(s)
AFF A250A 24 Nodes 12 Nodes 9.8RC1
AFF A250A 100V 24 Nodes 12 Nodes 9.8P4
AFF A400A Ethernet Bundle 24 Nodes 12 Nodes 9.7RC1
AFF A400A FC Bundle 24 Nodes 12 Nodes 9.7RC1
AFF A700A 24 Nodes 12 Nodes 9.4RC1
AFF A800A 24 Nodes 12 Nodes 9.4RC1
AFF A900A 24 Nodes 12 Nodes 9.10.1
AFF C190A 10GBASE-T 24 Nodes 12 Nodes 9.6RC2
AFF C190A UTA2 24 Nodes 12 Nodes 9.6RC2
FAS - Legacy EOA Configuration(s)
FAS8200A 24 Nodes 12 Nodes 9.4RC1
AllFlashFAS - Legacy EOA Configuration(s)
AFF A220A 10GBASE-T 24 Nodes 12 Nodes 9.4RC1
AFF A220A UTA2 24 Nodes 12 Nodes 9.4RC1
AFF A300A 24 Nodes 12 Nodes 9.4RC1
AFF A320A 24 Nodes 12 Nodes 9.6RC2
AFF A700s 24 Nodes 12 Nodes 9.4RC1
Footnote:
1Maximum number of nodes within a cluster is determined by platform which supports the fewest number of nodes

Product Standard Compliance - FAS2720 2-Port UTA2 Single Chassis HA Pair

Standard Description
Certifications EMC/EMI
AMCA Australia and New Zealand (EMC covered by ACMA DoC)
FCC Federal Communications Commission (EMI Declaration of Conformity covering United States and Canada)
ICES ICES
KC Korea Communications Commission (EMC certificate for South Korea)
Morocco Morocco Declaration of Conformity
VCCI EMI Certificate for Japan
Certifications safety
BIS Bureau of Indian Standard (Safety cert for India)
CB Certificate Body issued safety certificate covering International
CSA Canadian Standards Association issued Safety certificate covering North America
G_K_U-SoR Safety certificate for Gabon, Kenya and Uganda
IRAM Instituto Argentino de Normalización y Certificación (safety certificate for Argentina)
NOM Norma Oficial Mexicana (Safety cert for Mexico)
NRCS National Regulator for Compulsory Specifications (Safety cert for South Africa)
SONCAP Standards Organisation of Nigeria Conformity Assessment Programme (Safety cert for Nigeria)
TBS Tanzanian Bureau of Standards (Safety certificate for Tanzania)
Certifications Safety/EMC/EMI
EAC Euro Asia Conformity (EMC and Safety Cert) covering (Russia, Kazakhstan, Belarus, Armenia, Kyrgyzstan Countries)
UKRSEPRO EMC/Safety certificate for Ukraine
Certifications Safety/EMC/EMI/RoHS
BSMI Certificate for Taiwan
CE DoC European Union Declaration of Conformity
UKCA DoC UK Declaration of Conformity
Standards EMC/EMI
BS-EN-55024 EMC standard for Great Britain
BS-EN55035 EMC standard for Great Britain
CISPR 32 EMI
EN55022 EMC Standard fo European Union
EN55024 EMC Standard fo European Union
EN55032 EMI Standard fo European Union
EN55035 EMC Standard for European Union
EN61000-3-2 EMC Standard for European Union
EN61000-3-3 EMC Standard for European Union
FCC Part 15 Class A EMI standard for United States
ICES-003 EMI Standard for Canada
KS C 9832 EMI Standard for South Korea
KS C 9835 EMC Standard for South Korea
Standards Safety
ANSI/UL60950-1 Safety standard for United States
ANSI/UL62368-1 Safety standard for United States
BS-EN62368-1 Safety standard for Great Britain
CAN/CSA C22.2 No. 60950-1 Safety Standard for Canada
CAN/CSA C22.2 No. 62368-1 Safety Standard for Canada
CNS 14336 Safety Standard for Taiwan
EN60825-1 Laser Safety standard for European Union
EN62368-1 Safety standard for European Union
IEC 62368-1 Safety Standard for International
IEC60950-1 Safety standard for International
IS 13252(part 1) Safety Standard for India

Supported OS Version - FAS2720 2-Port UTA2 Single Chassis HA Pair

OS Major Version Supported OS Version Supported Milestones Recommend Version
Currently Supported OS
ONTAP 9.11.1 9.11.1, 9.11.1RC1 End of Full Support: 31-Jul-2025
End of Limited Support: 31-Jul-2027
End of Self-Service Support: 31-Jul-2030
9.11.1
ONTAP 9.10.1 9.10.1P5, 9.10.1P6, 9.10.1P4, 9.10.1P3, 9.10.1P2, 9.10.1P1, 9.10.1, 9.10.1RC1 End of Full Support: 31-Jan-2025
End of Limited Support: 31-Jan-2027
End of Self-Service Support: 31-Jan-2030
9.10.1P6
ONTAP 9.9.1 9.9.1P10, 9.9.1P9, 9.9.1P8, 9.9.1P7, 9.9.1P6, 9.9.1P5, 9.9.1P4, 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 End of Full Support: 30-Jun-2024
End of Limited Support: 30-Jun-2026
End of Self-Service Support: 30-Jun-2029
9.9.1P10, 9.9.1P9
ONTAP 9.8 9.8P13, 9.8P12, 9.8P11, 9.8P10, 9.8P9, 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4, 9.8P3, 9.8P2, 9.8P1, 9.8, 9.8RC1 End of Full Support: 31-Dec-2023
End of Limited Support: 31-Dec-2025
End of Self-Service Support: 31-Dec-2028
9.8P13, 9.8P12
ONTAP 9.7 9.7P19, 9.7P18, 9.7P17, 9.7P16, 9.7P15, 9.7P14, 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 End of Full Support: 31-Jan-2023
End of Limited Support: 31-Jan-2025
End of Self-Service Support: 31-Jan-2028
9.7P19
EOS OS
ONTAP 9.7 9.7P19, 9.7P18, 9.7P17, 9.7P16, 9.7P15, 9.7P14, 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 End of Full Support: 31-Jan-2023
End of Limited Support: 31-Jan-2025
End of Self-Service Support: 31-Jan-2028
9.7P19
ONTAP 9.6 9.6P18, 9.6P17, 9.6P16, 9.6P15, 9.6P14, 9.6P13, 9.6P12, 9.6P11, 9.6P10, 9.6P9, 9.6P8, 9.6P7, 9.6P6, 9.6P5, 9.6P4, 9.6P3, 9.6P2, 9.6P1, 9.6, 9.6RC2, 9.6RC1 End of Full Support: 30-Jun-2022
End of Limited Support: 30-Jun-2024
End of Self-Service Support: 30-Jun-2027
9.6P18
ONTAP 9.5 9.5P19, 9.5P18, 9.5P17, 9.5P16, 9.5P15, 9.5P14, 9.5P13, 9.5P12, 9.5P11, 9.5P10, 9.5P9, 9.5P8, 9.5P7, 9.5P6, 9.5P5, 9.5P4, 9.5P3, 9.5P2, 9.5P1, 9.5, 9.5RC1 End of Full Support: 31-Jan-2022
End of Limited Support: 31-Jan-2024
End of Self-Service Support: 31-Jan-2027
9.5P19
Definitions:
[1]End of Full Support: The date marking the end of Full Support for a particular feature version of a NetApp system software and the beginning of Limited Support. Abbreviated as EOES.
[2]End of Limited Support: The date marking the end of Limited Support for a particular feature version of a product and transition to Self-Service Support. Abbreviated as EOVS.
[3]End of Self-Service Support: NetApp does not provide support for a version of a software product, but related documentation is still available on the NetApp Support Site. NetApp customers are expected to utilize documentation to resolve issues.

Supported Power Cords for FAS2720 2-Port UTA2 Single Chassis HA Pair

Marketing Part No.End 1 / End 2LengthDescription
Non-Cabinet Power Cords
X-50617-00 IEC60320-C20 / IEC60320-C13 2.00 m Power Cords,In-Cabinet,2m,C20-C13,E-Series
X800B-R6 CEE 7/7 (Schuko) / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Cont Europe/Korea,10A/250V
X800C-R6 BS1363 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,UK/Ireland,10A/250V
X800D-R6 JIS-C-8303 / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,Japan,15A/125V
X800E-R6 NEMA 5-15P / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,North America,15A/125V
X800F-R6 AS/NZS 3112 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Aus/NZ,10A/250V
X800G-R6 SEV 1011 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Switzerland,10A/250V
X800H-R6 IRAM 2073 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Argentina,10A/250V
X800I-R6 GB2099 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,China,10A/250V
X800J-R6 DHCR107-2-D1 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Demark,10A/250V
X800K-R6 SANS 164-1 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,India/S.Africa,10A/250V
X800L-R6 SI32 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Israel,10A/250V
X800M-R6 CEI 23-16 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Italy,10A/250V
X800N EL208 / IEC60320-C13 2.50 m Pwr Cord,10A,250V,2.5m,India
X800P-R6 NEMA 6-15P / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,North America,15A/250V
X800T-R6 CNS 10917-3 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Taiwan,BSMI,15A/125V
X800VB-R6 NBR14136 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Brazil,10A/250V
X800W-R6 CNS10917/CNS690 / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,Taiwan,10A/250V
X800Y-R6 JIS-C-830 / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,Japan,15A/250V
In-Cabinet Power Cords
X-50617-00-0E-C IEC60320-C13 / IEC60320-C20 1.83 m Power Cord,In-Cabinet,2m,C20-C13,E-Series,0E,-C
X1558A-R6 IEC60320-C14 / IEC60320-C13 1.20 m Pwr Cord,In-Cabinet,48-In,C13-C14,10A/250V
X800-42U-35 IEC60320-C14 / IEC60320-C13 0.89 m Pwr Cord,In-Cabinet,C13-C14,35-inch
X800-42U-43 IEC60320-C14 / IEC60320-C13 1.09 m Pwr Cord,In-Cabinet,C13-C14,43-inch
X800-42U-64 IEC60320-C14 / IEC60320-C13 1.63 m Pwr Cord,In-Cabinet,C13-C14,64-inch
X800-42U-R6 IEC60320-C14 / IEC60320-C13 0.68 m Pwr Cord,In-Cabinet,27-In,C13-C14,10A/250V

Onboard Ports Configuration: FAS2720 2-Port UTA2 Single Chassis HA Pair

Port Address Description Supported Protocols Port Icon Port Type
0a Serial-Attached SCSI SAS 6/12 Gb Circle MiniSAS HD
0b Serial-Attached SCSI SAS 6/12 Gb Square MiniSAS HD
e0a Ethernet Ethernet 10Gb Ethernet SFP+
e0b Ethernet Ethernet 10Gb Ethernet SFP+
e0c/0c [1] Unified Target Adapter 2 Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb Ethernet/Fibre Channel SFP+
e0d/0d [1] Unified Target Adapter 2 Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb Ethernet/Fibre Channel SFP+
e0m/BMC Management Ethernet 10/100/1000 Mb Wrench RJ45
Serial Interface USB Serial Console RS-232 115200bps USB 2.0 USB 2.0 Micro-B
Serial Interface Icon Serial Console RS-232 115200bps Serial Interface RJ45
USB/2 Storage Host Port USB 2.0 USB 2.0 USB Type A
Footnote:
1Connecting tape drives or tape libraries to the FC or UTA2 ports requires the use of a FC switch.

Supported Platform Configurations - FAS2720 2-Port UTA2 Single Chassis HA Pair

Platform Configuration Description Chassis Configuration Chassis Count Controller Count (per chassis) IOXM Count (per chassis) Rack Units (Per System) Weight (Per Chassis) Min ONTAP
HA Pair
FAS2720A 10GBASE-T FAS2720 10GBASE-T Single Chassis HA Pair CC 1 2 0 2 41.23 lb (18.7 kg) 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
FAS2720A 2-port UTA2 FAS2720A 2-port UTA2 CC 1 2 0 2 41.23 lb (18.7 kg) 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
FAS2720A UTA2 FAS2720 UTA2 Single Chassis HA Pair CC 1 2 0 2 41.23 lb (18.7 kg) 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1

Platform Memory Specifications - FAS2720 2-Port UTA2 Single Chassis HA Pair

Part Number Description Mfg Part Number Non-Volatile Qty Capacity (GB) NVRAM/NVMEM Used Capacity (GB) RAM Used Capacity (GB)
X3222A R7,IC,SODIMM,16GB,x8,ECC,REG 107-00172 no 4 16 8 64

Supported Rail Kit for FAS2720 2-Port UTA2 Single Chassis HA Pair

Marketing Part No.Manufacturing Part No.Description
Third-Party Cabinet Rail Kits
X-02654-00 111-02852 Kit,2-Post, Thin
X-02657-00 111-02657 Kit,4-Post,Thin,Rnd/Sq-Hole, 24"-32" Rail

Supported Firmware Matrix - FAS2720 2-Port UTA2 Single Chassis HA Pair

Major OS Version OS Version Firmeware
BIOS
ONTAP 9.11.1 9.11.1 11.15*
ONTAP 9.11.1 9.11.1RC1 11.16, 11.15*
ONTAP 9.10.1 9.10.1P5-P6 11.16, 11.15*
ONTAP 9.10.1 9.10.1P3-P4, 9.10.1P2, 9.10.1P1 11.16, 11.15, 11.13*
ONTAP 9.10.1 9.10.1, 9.10.1RC1 11.16, 11.15, 11.13, 11.11*
ONTAP 9.9.1 9.9.1P10 11.16, 11.15*
ONTAP 9.9.1 9.9.1P8-P9, 9.9.1P7 11.16, 11.15, 11.13*
ONTAP 9.9.1 9.9.1P4-P6, 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 11.16, 11.15, 11.13, 11.11*
ONTAP 9.8 9.8P13 11.16, 11.15*
ONTAP 9.8 9.8P11-P12 11.16, 11.15, 11.13*
ONTAP 9.8 9.8P10, 9.8P9, 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4 11.16, 11.15, 11.13, 11.11*
ONTAP 9.8 9.8P3, 9.8P2, 9.8P1, 9.8, 9.8RC1 11.16, 11.15, 11.13, 11.11, 11.9*
ONTAP 9.7 9.7P19, 9.7P17-P18, 9.7P16, 9.7P15, 9.7P14 11.16, 11.15, 11.13, 11.11*
ONTAP 9.7 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8 11.16, 11.15, 11.13, 11.11, 11.9*
ONTAP 9.7 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7*
ONTAP 9.6 9.6P18, 9.6P17, 9.6P16, 9.6P15 11.16, 11.15, 11.13, 11.11*
ONTAP 9.6 9.6P13-P14, 9.6P12 11.16, 11.15, 11.13, 11.11, 11.9*
ONTAP 9.6 9.6P10-P11 11.16, 11.15, 11.13, 11.11, 11.9, 11.7*
ONTAP 9.6 9.6P9, 9.6P7-P8, 9.6P5-P6, 9.6P4, 9.6P3 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5*
ONTAP 9.6 9.6P2, 9.6, 9.6P1, 9.6RC2, 9.6RC1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5*
ONTAP 9.5 9.5P19, 9.5P18 11.16, 11.15, 11.13, 11.11*
ONTAP 9.5 9.5P17, 9.5P16, 9.5P15 11.16, 11.15, 11.13, 11.11, 11.9*
ONTAP 9.5 9.5P14 11.16, 11.15, 11.13, 11.11, 11.9, 11.7*
ONTAP 9.5 9.5P13, 9.5P12, 9.5P10-P11, 9.5P9, 9.5P8, 9.5P7, 9.5P6, 9.5P5, 9.5P4, 9.5P2-P3, 9.5P1, 9.5, 9.5RC1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4*
ONTAP 9.4 9.4P8, 9.4P7, 9.4P6, 9.4P5, 9.4P4, 9.4P3, 9.4P2, 9.4P1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4, 11.2.1*
ONTAP 9.4 9.4, 9.4RC1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4, 11.2.1, 11.2*
BMC
ONTAP 9.11.1 9.11.1, 9.11.1RC1 11.8*
ONTAP 9.10.1 9.10.1P5-P6 11.8*
ONTAP 9.10.1 9.10.1P3-P4, 9.10.1P2, 9.10.1P1, 9.10.1, 9.10.1RC1 11.8, 11.7*
ONTAP 9.9.1 9.9.1P10, 9.9.1P8-P9, 9.9.1P7, 9.9.1P4-P6 11.8, 11.7*
ONTAP 9.9.1 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 11.8, 11.7, 11.6*
ONTAP 9.8 9.8P13 11.8*
ONTAP 9.8 9.8P11-P12, 9.8P10, 9.8P9, 9.8P8 11.8, 11.7*
ONTAP 9.8 9.8P7, 9.8P6, 9.8P5, 9.8P4, 9.8P3 11.8, 11.7, 11.6*
ONTAP 9.8 9.8P2, 9.8P1 11.8, 11.7, 11.6, 11.5P1*
ONTAP 9.8 9.8, 9.8RC1 11.8, 11.7, 11.6, 11.5P1, 11.5*
ONTAP 9.7 9.7P19, 9.7P17-P18 11.8, 11.7*
ONTAP 9.7 9.7P16, 9.7P15, 9.7P14, 9.7P13 11.8, 11.7, 11.6*
ONTAP 9.7 9.7P12, 9.7P11 11.8, 11.7, 11.6, 11.5P1*
ONTAP 9.7 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6 11.8, 11.7, 11.6, 11.5P1, 11.5*
ONTAP 9.7 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4*
ONTAP 9.6 9.6P18, 9.6P17 11.8, 11.7*
ONTAP 9.6 9.6P16, 9.6P15 11.8, 11.7, 11.6*
ONTAP 9.6 9.6P13-P14 11.8, 11.7, 11.6, 11.5P1*
ONTAP 9.6 9.6P12, 9.6P10-P11 11.8, 11.7, 11.6, 11.5P1, 11.5*
ONTAP 9.6 9.6P9, 9.6P7-P8, 9.6P5-P6 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4*
ONTAP 9.6 9.6P4, 9.6P3 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2*
ONTAP 9.6 9.6P2 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1*
ONTAP 9.6 9.6, 9.6P1, 9.6RC2, 9.6RC1 11.8, 11.7, 11.6, 11.5P1, 11.5*, 11.4, 11.3P2, 11.3P1*
ONTAP 9.5 9.5P19 11.8, 11.7*
ONTAP 9.5 9.5P18 11.8, 11.7, 11.6*
ONTAP 9.5 9.5P17, 9.5P16 11.8, 11.7, 11.6, 11.5P1*
ONTAP 9.5 9.5P15, 9.5P14 11.8, 11.7, 11.6, 11.5P1, 11.5*
ONTAP 9.5 9.5P13, 9.5P12, 9.5P10-P11 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4*
ONTAP 9.5 9.5P9, 9.5P8, 9.5P7 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2*
ONTAP 9.5 9.5P6 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1*
ONTAP 9.5 9.5P5, 9.5P4, 9.5P2-P3, 9.5P1, 9.5, 9.5RC1 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.2*
ONTAP 9.4 9.4P8 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1*
ONTAP 9.4 9.4P7, 9.4P6, 9.4P5, 9.4P4, 9.4P3 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.1P3*
ONTAP 9.4 9.4P2 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.1P3, 11.1P2*
ONTAP 9.4 9.4P1, 9.4, 9.4RC1 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.1P3, 11.1P2, 11.1*
Footnote:
[1]* Indicates that firmware is bundled with Storage OS Version

Product Certificates - FAS2720 UTA2 Single Chassis HA Pair

Certificate Name Geo / Region / Country Associated Products
Battery Pack safety reports
Lithium Battery Safety Doc-Section II/Section IB Shipments,Inventus Power Product Model#271-00045AWB Global Platforms : AFF A220, AFF A320, AFF A400, AFF A700s, AFF A800, AFF C190, FAS2620, FAS2650, FAS2720, FAS2750, FAS8300, FAS8700
EMI and Safety certificates
Declaraion of Similarity NAJ-1502 Global Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 G-K-U-SoR Gabon,Kenya,SaudiArabia,Uganda Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 (FXN Taiwan) BIS BIS - India Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 (Jabil Mexico) BIS BIS - India Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 (Jabil Singapore) BIS BIS - India Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 60950-CB CB - International Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 62368-CB CB - International Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 ACMA ACMA - Australia, New Zealand Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 BSMI BSMI - Taiwan Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 CSA CSA - United States, Canada Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 DoC CE CE - European Union DoC Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 EAC EAC - Armenia, Belarus, Kazakhstan, Kyrgyzstan, Russia Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 IRAM IRAM - Argentina Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 KC KC - South Korea Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 Morocco Morocco Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 NOM NOM - Mexico Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 NRCS NRCS - South Africa (Safety) Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 SONCAP SONCAP - Nigeria Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 TBS TBS - Tanzania Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 UKRSep Global Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 VCCI VCCI - Japan Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 FCC FCC - United States Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 UKCA DOC UKCA -United Kingdom Platforms : E2812, FAS2620, FAS2720, SG5712
PSU 80+ Platinum Certificates
DCJ9133-01 Energy Star Report Global Platforms : AFF A220, AFF C190, ASA AFF A220, FAS2720, FAS2750
TDPS-900AB A Energy Star Report Global Platforms : AFF A220, AFF C190, ASA AFF A220, FAS2720, FAS2750
Voluntary Product Accessibility Template
VPAT - NetApp Accessibility Conformance Report - NetApp FAS2720 Global Platforms : FAS2720

Size, Weight, Acoustic, Power FAS2720 2-Port UTA2 Single Chassis HA Pair

Associated Part No. Configuration Rack Units Weight Sound Power Sound Pressure Line Voltage Actual (Min to Max) Amps Typical Amps Worst Watts Typical Watts Worst BTU / Hr Typical BTU / Hr Worst
Embedded Drive Config (Empty)
FAS2720-100-C FAS2720 2 PCM no drives 2 41.2 lb (18.7 kg) 6.7 Bels 51 dBA 100 (100 to 120) 2.53 3.42 247 335 843 1144
FAS2720-100-C FAS2720 2 PCM no drives 2 41.2 lb (18.7 kg) 6.7 Bels 51 dBA 200 (200 to 240) 1.24 1.68 243 329 830 1123
Embedded Drive Config (Full)
FAS2720-101-C FAS2720 2 PCM 12x2TB NL-SAS 2 59.1 lb (26.8 kg) 6.7 Bels 51 dBA 100 (100 to 120) 3.65 4.55 357 445 1219 1519
FAS2720-101-C FAS2720 2 PCM 12x2TB NL-SAS 2 59.1 lb (26.8 kg) 6.7 Bels 51 dBA 200 (200 to 240) 1.79 2.23 350 437 1195 1492
FAS2720-102-C FAS2720 2 PCM 12x4TB 2 61.1 lb (27.7 kg) 6.7 Bels 51 dBA 100 (100 to 120) 4.14 5.04 405 493 1383 1683
FAS2720-102-C FAS2720 2 PCM 12x4TB 2 61.1 lb (27.7 kg) 6.7 Bels 51 dBA 200 (200 to 240) 2.03 2.47 397 484 1355 1652
FAS2720-102-C FAS2720 2 PCM 12x4TB NSE 2 61.1 lb (27.7 kg) 6.7 Bels 51 dBA 100 (100 to 120) 4.14 5.04 405 493 1383 1683
FAS2720-102-C FAS2720 2 PCM 12x4TB NSE 2 61.1 lb (27.7 kg) 6.7 Bels 51 dBA 200 (200 to 240) 2.03 2.47 397 484 1355 1652
FAS2720-103-C FAS2720 2 PCM 12x8TB 2 63.5 lb (28.8 kg) 6.7 Bels 51 dBA 100 (100 to 120) 4.18 5.07 409 496 1396 1693
FAS2720-103-C FAS2720 2 PCM 12x8TB 2 63.5 lb (28.8 kg) 6.7 Bels 51 dBA 200 (200 to 240) 2.05 2.49 401 487 1369 1663
FAS2720-104-C FAS2720 2 PCM 12x10TB 2 60.4 lb (27.4 kg) 6.7 Bels 51 dBA 100 (100 to 120) 3.92 4.82 384 472 1311 1611
FAS2720-104-C FAS2720 2 PCM 12x10TB 2 60.4 lb (27.4 kg) 6.7 Bels 51 dBA 200 (200 to 240) 1.93 2.37 377 463 1287 1581
FAS2720-104-C FAS2720 2 PCM 12x10TB NSE 2 60.4 lb (27.4 kg) 6.7 Bels 51 dBA 100 (100 to 120) 3.92 4.82 384 472 1311 1611
FAS2720-104-C FAS2720 2 PCM 12x10TB NSE 2 60.4 lb (27.4 kg) 6.7 Bels 51 dBA 200 (200 to 240) 1.93 2.37 377 463 1287 1581
FAS2720-105-C FAS2720 2 PCM 12x10TB 2 60.4 lb (27.4 kg) 6.7 Bels 51 dBA 100 (100 to 120) 3.92 4.82 384 472 1311 1611
FAS2720-105-C FAS2720 2 PCM 12x10TB 2 60.4 lb (27.4 kg) 6.7 Bels 51 dBA 200 (200 to 240) 1.93 2.37 377 463 1287 1581
FAS2720-105-C FAS2720 2 PCM 12x10TB NSE 2 60.4 lb (27.4 kg) 6.7 Bels 51 dBA 100 (100 to 120) 3.92 4.82 384 472 1311 1611
FAS2720-105-C FAS2720 2 PCM 12x10TB NSE 2 60.4 lb (27.4 kg) 6.7 Bels 51 dBA 200 (200 to 240) 1.93 2.37 377 463 1287 1581
FAS2720-115-C FAS2720 2 PCM 12x16TB NL-SAS 2 60.6 lb (27.5 kg) 6.7 Bels 51 dBA 100 (100 to 120) 3.89 4.79 381 469 1301 1601
FAS2720-115-C FAS2720 2 PCM 12x16TB NL-SAS 2 60.6 lb (27.5 kg) 6.7 Bels 51 dBA 200 (200 to 240) 1.91 2.35 374 460 1277 1570
Embedded Drive Config (Mixed)
FAS2720-106-C FAS2720 2 PCM 4x960GB, 8x2TB 2 55.1 lb (25.0 kg) 6.7 Bels 51 dBA 100 (100 to 120) 3.8 4.7 372 460 1270 1570
FAS2720-106-C FAS2720 2 PCM 4x960GB, 8x2TB 2 55.1 lb (25.0 kg) 6.7 Bels 51 dBA 200 (200 to 240) 1.87 2.31 365 451 1246 1540
FAS2720-107-C FAS2720 2 PCM 4x960GB, 8x4TB 2 56.4 lb (25.6 kg) 6.7 Bels 51 dBA 100 (100 to 120) 4.05 4.94 396 484 1352 1652
FAS2720-107-C FAS2720 2 PCM 4x960GB, 8x4TB 2 56.4 lb (25.6 kg) 6.7 Bels 51 dBA 200 (200 to 240) 1.99 2.43 389 475 1328 1622
FAS2720-108-C FAS2720 2 PCM 4x960GB, 8x8TB 2 58.0 lb (26.3 kg) 6.7 Bels 51 dBA 100 (100 to 120) 4.07 4.96 398 486 1359 1659
FAS2720-108-C FAS2720 2 PCM 4x960GB, 8x8TB 2 58.0 lb (26.3 kg) 6.7 Bels 51 dBA 200 (200 to 240) 2 2.44 391 477 1335 1628
FAS2720-109-C FAS2720 2 PCM 4x960GB, 8x10TB 2 56.0 lb (25.4 kg) 6.7 Bels 51 dBA 100 (100 to 120) 3.9 4.8 382 470 1304 1605
FAS2720-109-C FAS2720 2 PCM 4x960GB, 8x10TB 2 56.0 lb (25.4 kg) 6.7 Bels 51 dBA 200 (200 to 240) 1.92 2.36 375 461 1280 1574
FAS2720-111-C FAS2720 2 PCM 4x3.8TB, 8x4TB 2 56.4 lb (25.6 kg) 6.7 Bels 51 dBA 100 (100 to 120) 4.08 4.97 399 487 1362 1663
FAS2720-111-C FAS2720 2 PCM 4x3.8TB, 8x4TB 2 56.4 lb (25.6 kg) 6.7 Bels 51 dBA 200 (200 to 240) 2 2.44 392 478 1338 1632
FAS2720-112-C FAS2720 2 PCM 4x3.8TB, 8x8TB 2 58.0 lb (26.3 kg) 6.7 Bels 51 dBA 100 (100 to 120) 4.11 5 402 490 1372 1673
FAS2720-112-C FAS2720 2 PCM 4x3.8TB, 8x8TB 2 58.0 lb (26.3 kg) 6.7 Bels 51 dBA 200 (200 to 240) 2.02 2.46 394 481 1345 1642
FAS2720-116-C FAS2720 2 PCM 4x960GB, 8x16TB 2 54.9 lb (24.9 kg) 6.7 Bels 51 dBA 100 (100 to 120) 3.63 4.53 355 443 1212 1512
FAS2720-116-C FAS2720 2 PCM 4x960GB, 8x16TB 2 54.9 lb (24.9 kg) 6.7 Bels 51 dBA 200 (200 to 240) 1.78 2.22 348 435 1188 1485
FAS2720-117-C FAS2720 2 PCM 4x3.8TB, 8x16TB 2 54.9 lb (24.9 kg) 6.7 Bels 51 dBA 100 (100 to 120) 3.63 4.53 355 443 1212 1512
FAS2720-117-C FAS2720 2 PCM 4x3.8TB, 8x16TB 2 54.9 lb (24.9 kg) 6.7 Bels 51 dBA 200 (200 to 240) 1.78 2.22 348 435 1188 1485

 

Shipping Information

Express Computer Systems can ship to virtually any address in the world and provides you with the best shipping rates possible. Cost of shipping varies depending on what service you require, your destination and size of the shipment. Shipping costs will be calculated separately from your order and billed to you post purchase. In the notes section of your order please provide us with your preferred shipping method and we will get back to you.

Custom configured orders ship within 2 business days after all required products are in stock.

Please allow 3 business days for products that are not in stock to arrive to our facility in Irvine, California.

Domestic Shipments
  • Standard Ground
    • Shipping time: 2-7 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-10 business days
    • Excludes weekends, holidays or weather delays.
  • 3 Business Days
    • Shipping time: 3 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 3-6 business days
    • Excludes weekends, holidays or weather delays.
  • 2 Business Days
    • Shipping time: 2 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-5 business days
    • Excludes weekends, holidays or weather delays.
  • Overnight / Next Business Day
    • Shipping time: 1 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 1-4 business days
    • Excludes weekends, holidays or weather delays.
International Shipments
  • International Economy
    • Shipping time: 4-6 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 5-9 business days
    • Excludes weekends, holidays or weather delays.
  • International Priority
    • Shipping time: 1-3 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-6 business days
    • Excludes weekends, holidays or weather delays.

For more information on shipping view our Shipping Information page or send us a message

ECS Warranty Information

Express Computer Systems (ECS) provides a 1 year parts warranty against defects in material or workmanship that will affect the products functionality. All refurbished items are tested prior to shipping to guarantee up-time upon arrival. If you are having issues with an item we provided please Contact Us and we will do our best to assist you.

What does our ECS warranty cover?
We offer 1 year warranty as standard and additional years can be added to fit your needs. Please reach out to a sales associate via the Contact Us page or live chat for more information on extended coverage options. During the coverage period if your product fails we will offer a Next Business Day replacement. If we are unable to replace the product we will refund its original selling price. Shipping costs and tax are not refundable. Express Computer Systems retains the right to decide whether the goods will be replaced or refunded.

What is not covered by our warranty?
Our warranty does not cover any problem caused by the following conditions:

  1. accidents; misuse; carelessness; electrostatic discharge; shock; temperature or humidity beyond the specifications of the product; improper installation; operation; modification;
  2. any improper use that contravenes the instructions in the user manual;
  3. problems caused by other equipment. Our warranty is void if the product is returned with damaged, removed, counterfeit labels, or any modifications (including any component or external cover removal). Our warranties do not cover data loss or damages to any other equipment. In addition, our warranties do not cover incidental damages, consequential damages, or costs related to data recovery, removal, and installation.

Important notes:

  • Please ask for additional warranty/coverage that you may require in addition to the standard 1 ECS warranty prior to final purchase. Requesting additional warranty after your purchase can be denied.
  • FREE technical support is provided on purchased items via phone, email, or live chat.

About Express Computer Systems

Express Computer Systems is committed to transforming our customers’ IT infrastructure with high quality products at affordable costs. Our sales reps and customer support engineers understand our customers rely heavily on advanced technology to run their business but need to do so without breaking the bank.

We specialize in building custom server configurations, custom storage solutions, networking solutions, and components from top manufacturers including HPE, Dell, Cisco, NetApp, Dell EMC, HPE Nimble and many others.

Subscribe