Storage Limits
Max # of Drives (Total) | Max # of Internal Drives | Max # of NL-SAS Drives | Max # of SAS Drives | Max # of SATA Drives | Max # of SSD Drives | Max # of DS212C Shelves | Max # of DS2246 Shelves | Max # of DS224C Shelves | Max # of DS4243 Shelves | Max # of DS4246 Shelves | Max # of DS460C Shelves |
---|---|---|---|---|---|---|---|---|---|---|---|
144 | 12 | 144 | 144 | 144 | 136 | 1 internal + 9 external | 6 external | 6 external | 6 external | 6 external | 2 external |
Capacity Limits
Marketing Maximum Raw Capacity - Node | HA Pair | Cluster | Effective Capacity - Node | HA Pair | Cluster |
---|---|---|---|---|---|
2304000 | 2304000 | Detailed Matrix | 10226304 | 10226304 |
Core Cluster Limits
Max SVM's - NAS - Node / HA Pair / Cluster | Max LIF's - NAS - Node / HA Pair / Cluster | Max Connections - NAS - Node / HA Pair(Non-Scalable) | Max Flexible Volumes - NAS - Aggregate (Single data Agg. per Node) / Aggregate (Multiple data Agg. per Node) / Node/ HA Pair / Cluster | Max Flexible Volumes with DPO - NAS - Node/ HA Pair / Cluster | Max Lock Manager Locked Objects - Node/HA Pair/Cluster | Max Intercluster LIFs - Node | Min Root Aggregate (MiB) - Node | Min Root Volume (GiB) - Node | Max IPsec Policies - SVM / Cluster | Max Auditing-Enabled SVMs - Cluster |
---|---|---|---|---|---|---|---|---|---|---|
/ / 512 | 512 / 512 / 3072 | 100000 / 100000 | / / 1000 / 2000 / 15000 | 1500 / 3000 / 12000 | 1200000 / 1200000 / 12288000 | 8 | 191488 | 150 | 256 / 1500 | 50 |
System Maximums and Limits
Max Nodes per Cluster (NAS / SAN) | Max FabricPool Size | Max Infinite Volume Data Constituent Size | Max FlexGroup Data Constituent Size | Min Root Volume Size | NetApp Volume Encryption |
---|---|---|---|---|---|
Not Supported / Not Supported | 8400 TiB | Not Supported | 150 GiB [1] | Supported |
Processor
Processor Model | Processor Architecture | Processor Speed | Processor Count (Per Node) | Processor Count (Per Config) | Processor Cores (Per CPU) | Processor Cores (Per Node) | Processor Cores (Per Config) |
---|---|---|---|---|---|---|---|
64-bit 12-core 1.50 Ghz | 64 bit | 1.50 Ghz | 1 | 2 | 12 | 12 | 24 |
Memory
Detailed Memory Matrix | NVME (Per Node) | NVME (Per Config) | NVMEM (Per Node) | NVMEM (Per Config) | RAM (Per Node) | RAM (Per Config) |
---|---|---|---|---|---|---|
Platform Memory Specifications | 1024 GB | 2048 GB | 4 GB | 8 GB | 32 GB | 64 GB |
Onboard Ports
Full Onboard Ports Matrix | Ethernet Ports | Fibre Channel | Ports UTA2 Ports | Expansion Slots | SAS Ports |
---|---|---|---|---|---|
Onboard Ports & Cables | 4 x SFP+ (10Gb) | - | - | 4 x MiniSAS HD (12Gb) |
Physical Characteristics
Rack Units | Chassis Height | Chassis Width with Mounting Flanges | Chassis Width without Mounting Flanges | Chassis Depth with Cable Mgmt | Chassis Depth without Cable Mgmt | Chassis Weight |
---|---|---|---|---|---|---|
2 | 3.42" (8.69 cm) | 18.9" (48 cm) | 17.6" (44.7 cm) | 25.12" (63.8 cm) | 20" (50.8 cm) | See Weights by configuration |
System Clearance Dimensions
Front Clearance (Cooling) | Front Clearance (Maintenance) | Rear Clearance (Cooling) | Rear Clearance (Maintenance) |
---|---|---|---|
6.03" (15.3 cm) | 24.03" (61 cm) | 6.03" (15.3 cm) | 13" (33 cm) |
Environmental Requirements
Operating Temp / Humidity / Altitude | Storage Temp / Humidity / Altitude | Transit Temp / Humidity / Altitude | Acoustic Noise - Sound Power / Pressure | Input Power Voltage |
---|---|---|---|---|
41 to 113 deg F - 5 to 45 deg C / 8 to 90 % / Up to 10000.0 ft - Up to 3048.0 m | -40 to 158 deg F - -40 to 70 deg C / 10 to 95 % / Up to 40000.0 ft - Up to 12192.0 m | -40 to 158 deg F - -40 to 70 deg C / 10 to 95 % / Up to 39989.8 ft - Up to 12192 m | 6.7 bels / 51 dBA | 100 to 120 |
Storage OS Requirements
Full OS Matrix | Recommended Version | Minimum OS | Maximum OS |
---|---|---|---|
View Full OS Report Below | 9.11.1 | 9.11.1RC1 | 9.11.1 |
Storage and Firmware
Full Firmware Matrix | BIOS | BMC |
---|---|---|
Full Firmware ReportBelow | 11.15* | 11.8* |
Product Standards Compliance
Full Compliance and Certificates Report | Cert. EMC/EMI | Cert. Safety | Cert. Safety/EMC/EMI | Cert. Safety/EMC/EMI/RoHS | Standard Safety/EMC/EMI | Standard Safety |
---|---|---|---|---|---|---|
Compliance and Certificates ReportBelow | AMCA, FCC, ICES, KC, Morocco, VCCI | BIS, CB, CSA, G_K_U-SoR, IRAM, NOM, NRCS, SONCAP, TBS | EAC, UKRSEPRO | BSMI, CE DoC, UKCA DoC | BS-EN-55024, BS-EN55035, CISPR 32, EN55022, EN55024, EN55032, EN55035, EN61000-3-2, EN61000-3-3, FCC Part 15 Class A, IC more... | ANSI/UL60950-1, ANSI/UL62368-1, BS-EN62368-1, CAN/CSA C22.2 No. 60950-1, CAN/CSA C22.2 No. 62368-1, CNS 14336, EN60825-1 more... |
NFS Cluster Limits
Max Export Policies | Max Export Rules | Max NFSv4 Access Control Entries | Max Client Objects - Node / HA Pair | Max pNFS objects - Node / HA Pair |
---|---|---|---|---|
24000 | 200000 | 1024 | 10000 / 10000 | 524288 / 524288 / 1048576 |
WAFL Cluster Limits - All Maximums
Size 64-bit Aggregate (TiB) | Size 64-bit Volume (TiB) | File size 64-bit Volume (TiB) | Snapshot - Volume / Node / HA Pair | Char's Snapshot | Hard links - File | inodes/files - Volume | qtrees - Volume / Node / HA Pair / Cluster | Concurrent DataMotion for Volumes ops - Node / HA Pair |
---|---|---|---|---|---|---|---|---|
800 | 100 | 16 | 1023 / 1023000 / 2046000 | 255 | 100000 | 2000000000 | 4995 / 100000 / 200000 / 400000 | 16 / 16 |
Quality of Service Cluster Limits
Max Policy Groups - Cluster | Max QoS User Workloads - Cluster |
---|---|
12000 | 40000 |
SAN Cluster Limits - All Maximums
SVMs - Node / HA Pair / Cluster | Flexible Vol - Node / HA Pair / Cluster | Flexible Vol with DPO - Node / HA Pair / Cluster | LUNs Vol - Node / HA Pair / Cluster | LUN mappings - Node / HA Pair / Cluster | LUN size (TiB) - LUN | Maximum FC queue depth available | SAN Hosts (ITNs) - Port / Node / HA Pair / Cluster | LIFS - iSCSI - Port / Portset / Node / HA Pair / Cluster | LIFS - FCP - Port / Portset / Node / HA Pair / Cluster | igroups - Node / HA Pair / Cluster | Initiators - igroup / Node / HA Pair / Cluster | Portsets - Node / HA Pair / Cluster | iSCSI sessions - Node / HA Pair / Cluster |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
125 / 250 / 1000 | / / 1000 / 2000 / 12000 | 1500 / 3000 / 12000 | 1024 / 8192 / 16384 / 65536 | 8192 / 16384 / 65536 | 16 | 2048 | 512 / 4096 / 8192 / 32768 | 32 / 32 / 512 / 1024 / 4096 | 32 / 32 / 512 / 1024 / 4096 | 2048 / 4096 / 16384 | 256 / 2048 / 4096 / 16384 | 2048 / 4096 / 16384 | 4096 / 8192 / 32768 |
CIFS Cluster Limits - All Maximums
Connected shares - Node / HA Pair | Regular shares - Node / HA Pair / Cluster | Open files - Connection / Node / HA Pair | Local users - Cluster | Local groups - Cluster | Local group members - Cluster |
---|---|---|---|---|---|
Detailed Matrix / 800000 | N/A / N/A / 60000 | 600000 / 600000 / 600000 | 5000 | 10000 | 30000 |
Data Protection Cluster Limits - All Maximums
NDMP Sessions - Node / HA Pair (Non-Scalable) | Data Protection Mirrors - Volume / Node / HA Pair / Cluster | Load Sharing Mirrors - NAS SVM | Concurrent Snap Mirror / SnapVault transfers - Node | DP Mirror fan-out - Volume | LS Mirror fan-out - NAS SVM | Clusters that can be peered - Cluster | Volumes, SnapMirror relationship - FlexGroup / FlexGroup-Node /HA Pair / Cluster | SnapMirror Synchronous relationships - Volume / Node / HA Pair (Non-Scalable) | Flexible Volumes in SVM DR - SVM / HA Pair | SVM Disaster recovery - Cluster |
---|---|---|---|---|---|---|---|---|---|---|
36 / 36 | 1 / 1000 / 2000 / 15000 | 2 | 100 | 8 | 2 | 255 | 200 / 50 / 1000 / 6000 | 1 / 20 / 20 | 300 / 1000 | 128 |
NVMe/oF Cluster Limits - All Maximums
Storage virtual machines (SVMs), NVMe/oF - Cluster | Flexible volumes, NVMe/oF - Node / HA Pair / Cluster | Flexible volumes with DPO, NVMe/oF - Node / HA Pair / Cluster | Namespaces - Volume / Node / HA Pair / Cluster | Subsystems - SVM / Cluster | Namespace Mappings - Subsystem / Node / HA Pair / Cluster | Namespace Size | Hosts - Subsystem | LIFS, NVMe/oF - Port / SVM / Node / HA Pair / Cluster | I/O Queue Count, NVMe/TCP - Controller | I/O Queue Depth - NVMe/TCP | Controllers, NVMe/TCP - Node |
---|---|---|---|---|---|---|---|---|---|---|---|
32 | 1000 / 2000 / 12000 | 1500 / 3000 / 12000 | 1024 / 8192 / 16384 / 65536 | 512 / 512 | 1024 / 8192 / 16384 / 65536 | 16 | 64 | 16 / 8 / 32 / 32 / 32 | 2 | 128 | 1024 |
FlexCache Cluster Limits - All Maximums Cache
Degree of fan-out - Origin | Origin Volumes - Node / HA Pair | Constituent Volumes - Node / HA Pair | Volumes - Node / HA Pair | Origin ConstituentVolumes - Node / HA Pair |
---|---|---|---|---|
100 | 100 / 200 | 800 / 1600 | 100 / 200 | 800 / 1600 |
S3 Cluster Limits - All Maximums
Number of Buckets - Vserver / Cluster | Number of Objects - Bucket | Number of Users - Vserver / Cluster | Size of the Bucket (PB) - Vserver |
---|---|---|---|
12000 / 12000 | 400000000000 | 4000 / 96000 | 20 |
Consistency Groups - All Maximums
Number of Consistency Groups - Cluster | Number of Parent Consistency Groups - Cluster | Consistency Groups and Parents - Cluster | Child Consistency Groups in a Parent - Parent Group | Flexible Volumes in a Consistency Group | Flexible Volumes for Child Consistency Groups under a Parent Group | Flexible Volumes in a Child Consistency Group |
---|---|---|---|---|---|---|
15000 | 15000 | 15000 | 5 | 80 | 80 |
Platform LED for FAS2720 2-Port UTA2 Single Chassis HA Pair
LED Label | LED Name | Type | Status Indicator | Description | |||||
---|---|---|---|---|---|---|---|---|---|
Front View | |||||||||
1 | Chassis Power Config | - | On Green | At least one of the two PSUs is delivering power to the system. | |||||
- | - | - | Off | Neither PSU is delivering power to the system. | |||||
2 | Chassis Attention LED, front | - | On Amber | The system halted or a fault occurred in the chassis. | |||||
- | - | - | Off | The system is operating normally. | |||||
3 | Location LED on chassis front | - | On or flashing blue | The LED has been manually activated to aid in physically locating equipment | |||||
- | - | - | Off | The LED has not been manually activated to aid in physically locating equipment | |||||
4 | Shelf ID Digital Display | - | Number Displayed | Digital Shelf ID | |||||
Back View | |||||||||
LED Label | LED Name | Type | Status Indicator | Description | |||||
0a | Port SAS 2 LED Onboard Config | Attention | Yellow | SAS link requires attention | |||||
- | - | - | Off | SAS link operates as normal | |||||
- | - | Link | Green | Link is established on at least one external SAS lane | |||||
- | - | - | Off | No link is established on any external SAS lane | |||||
0b | Port SAS 2 LED Onboard Config | Attention | Yellow | SAS link requires attention | |||||
- | - | - | Off | SAS link operates as normal | |||||
- | - | Link | Green | Link is established on at least one external SAS lane | |||||
- | - | - | Off | No link is established on any external SAS lane | |||||
e0a | Port Ethernet SFP Config | Attention | Yellow | Ethernet Port requires attention. | |||||
- | - | - | Off | Ethernet port operates as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0b | Port Ethernet SFP Config | Attention | Yellow | Ethernet Port requires attention. | |||||
- | - | - | Off | Ethernet port operates as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0c/0c | Port UTA2 Config (Ethernet personality) | Attention | Off | Port is operating as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Yellow | Port requires attention | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0c/0c | Port UTA2 Config (FC personality) | Attention | Off | Port is operating as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Yellow | Port requires attention | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0d/0d | Port UTA2 Config (Ethernet personality) | Attention | Off | Port is operating as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Yellow | Port requires attention | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0d/0d | Port UTA2 Config (FC personality) | Attention | Off | Port is operating as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Yellow | Port requires attention | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0m/BMC | Ethernet On/Off | Port Activity | Blinking green | Traffic is present on the active link | |||||
- | - | - | Off | Off | |||||
- | - | Port Link | Solid green | On | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Yellow | Port requires attention | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0f/0f | Port UTA2 Config (Ethernet personality) | Attention | Off | Port is operating as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Yellow | Port requires attention | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0f/0f | Port UTA2 Config (FC personality) | Attention | Off | Port is operating as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Yellow | Port requires attention | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0m/BMC | Ethernet On/Off | Port Activity | Blinking green | Traffic is present on the active link | |||||
- | - | - | Off | Off | |||||
- | - | Port Link | Solid green | On |
Supported Shelves Drives for FAS2720 2-Port UTA2 Single Chassis HA Pair
Part No. | Capacity | RPM | Drive Type | Encryption | Root-Data Partitioning | Root-Data-Data Partitioning | Storage Pool Partitioning | Max Drive Count | FlexArray |
---|---|---|---|---|---|---|---|---|---|
FAS2720A 2-port UTA2 Internal Drives | |||||||||
X302A-R5 | 1TB | 7.2K | SATA | No | Yes | No | No | 12 | No |
X306A-R5 | 2TB | 7.2K | SATA | No | Yes | No | No | 12 | No |
X308A-R5 | 3TB | 7.2K | SATA | No | Yes | No | No | 12 | No |
X315A-R6 [1] [2] | 4TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 12 | No |
X318A-R6 | 8TB | 7.2K | NL-SAS | No | Yes | No | No | 12 | No |
X322A [1] | 10TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 12 | No |
X336A-R6 | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 12 | No |
X339A | 2TB | 7.2K | NL-SAS | No | Yes | No | No | 12 | No |
X363A-R6 | 3.84TB | N/A | SSD | No | No | No | Yes | 4 | No |
X364A | 3.84TB | N/A | SSD | No | No | No | Yes | 4 | No |
X366A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 4 | No |
X374A | 960GB | N/A | SSD | No | No | No | Yes | 4 | No |
X380A | 10TB | 7.2K | NL-SAS | No | Yes | No | No | 12 | No |
X388A | 16TB | 7.2K | NL-SAS | No | Yes | No | No | 12 | No |
X448A-R6 | 200GB | N/A | SSD | No | No | No | Yes | 4 | No |
X449A-R6 | 800GB | N/A | SSD | No | No | No | Yes | 4 | No |
X477A-R6 | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 12 | No |
X488A-R5 | 900GB | 10K | SAS | No | Yes | No | No | 12 | No |
X489A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 12 | No |
X490A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 12 | No |
X575A-R6 | 400GB | N/A | SSD | No | No | No | Yes | 4 | No |
X576A-R6 | 1.6TB | N/A | SSD | No | No | No | Yes | 4 | No |
X577A-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 4 | No |
DS212C with IOM12 / IOM12B / IOM12 / IOM12B shelf modules | |||||||||
X302A-R5 | 1TB | 7.2K | SATA | No | Yes | No | No | 108 | No |
X306A-R5 | 2TB | 7.2K | SATA | No | Yes | No | No | 108 | No |
X308A-R5 | 3TB | 7.2K | SATA | No | Yes | No | No | 108 | No |
X315A-R6 [1] [2] | 4TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 108 | No |
X317A [1] | 6TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 108 | No |
X318A-R6 | 8TB | 7.2K | NL-SAS | No | Yes | No | No | 108 | No |
X322A [1] | 10TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 108 | No |
X336A-R6 | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 108 | No |
X339A | 2TB | 7.2K | NL-SAS | No | Yes | No | No | 108 | No |
X363A-R6 | 3.84TB | N/A | SSD | No | No | No | Yes | 108 | No |
X364A | 3.84TB | N/A | SSD | No | No | No | Yes | 108 | No |
X366A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 108 | No |
X374A | 960GB | N/A | SSD | No | No | No | Yes | 108 | No |
X380A | 10TB | 7.2K | NL-SAS | No | Yes | No | No | 108 | No |
X388A | 16TB | 7.2K | NL-SAS | No | Yes | No | No | 108 | No |
X448A-R6 | 200GB | N/A | SSD | No | No | No | Yes | 108 | No |
X449A-R6 | 800GB | N/A | SSD | No | No | No | Yes | 108 | No |
X477A-R6 | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 108 | No |
X488A-R5 | 900GB | 10K | SAS | No | Yes | No | No | 108 | No |
X489A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 108 | No |
X490A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 108 | No |
X575A-R6 | 400GB | N/A | SSD | No | No | No | Yes | 108 | No |
X576A-R6 | 1.6TB | N/A | SSD | No | No | No | Yes | 108 | No |
X577A-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 108 | No |
DS224C with IOM12B / IOM12B / IOM12 / IOM12 shelf modules | |||||||||
X319A | 7.6TB | N/A | SSD | No | No | No | No | 132 | No |
X341A-R6 | 900GB | 10K | SAS | No | Yes | No | No | 132 | No |
X342A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 132 | No |
X343A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 132 | No |
X356A-R6 | 3.84TB | N/A | SSD | No | No | No | Yes | 132 | No |
X357A | 3.84TB | N/A | SSD | No | No | No | Yes | 132 | No |
X358A [1] | 3.84TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 132 | No |
X365A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 132 | No |
X371A | 960GB | N/A | SSD | No | No | No | Yes | 132 | No |
X386A [1] | 960GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 132 | No |
X417A-R6 [1] [2] | 900GB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 132 | No |
X422A-R5 | 600GB | 10K | SAS | No | Yes | No | No | 132 | No |
X423A-R5 | 900GB | 10K | SAS | No | Yes | No | No | 132 | No |
X425A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 132 | No |
X426A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 132 | No |
X427A [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 132 | No |
X427B-R6 [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 132 | No |
X438A-R6 | 400GB | N/A | SSD | No | No | No | Yes | 132 | No |
X439A-R6 | 1.6TB | N/A | SSD | No | No | No | Yes | 132 | No |
X440B-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 132 | No |
X446B-R6 | 200GB | N/A | SSD | No | No | No | Yes | 132 | No |
X447A-R6 | 800GB | N/A | SSD | No | No | No | Yes | 132 | No |
X670A | 15.3TB | N/A | SSD | No | No | No | No | 132 | No |
DS460C with IOM12 / IOM12B / IOM12 / IOM12B shelf modules | |||||||||
X379A | 960GB | N/A | SSD | No | No | No | Yes | 20 | No |
X375A | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 120 | No |
X376A | 8TB | 7.2K | NL-SAS | No | Yes | No | No | 120 | No |
X377A | 10TB | 7.2K | NL-SAS | No | Yes | No | No | 120 | No |
X378A [1] | 10TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 120 | No |
X387A | 16TB | 7.2K | NL-SAS | No | Yes | No | No | 120 | No |
DS2246 with IOM6 / IOM12 / IOM12 / IOM6 / IOM12B / IOM12B shelf modules | |||||||||
X341A-R6 | 900GB | 10K | SAS | No | Yes | No | No | 132 | No |
X342A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 132 | No |
X343A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 132 | No |
X356A-R6 | 3.84TB | N/A | SSD | No | No | No | Yes | 120 | No |
X357A | 3.84TB | N/A | SSD | No | No | No | Yes | 132 | No |
X358A [1] | 3.84TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 132 | No |
X365A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 132 | No |
X371A | 960GB | N/A | SSD | No | No | No | Yes | 132 | No |
X416A-R5 [1] | 600GB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 132 | No |
X417A-R6 [1] [2] | 900GB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 132 | No |
X421A-R5 | 450GB | 10K | SAS | No | Yes | No | No | 132 | No |
X422A-R5 | 600GB | 10K | SAS | No | Yes | No | No | 132 | No |
X423A-R5 | 900GB | 10K | SAS | No | Yes | No | No | 132 | No |
X425A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 132 | No |
X426A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 132 | No |
X427A [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 132 | No |
X427B-R6 [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 132 | No |
X438A-R6 | 400GB | N/A | SSD | No | No | No | Yes | 132 | No |
X439A-R6 | 1.6TB | N/A | SSD | No | No | No | Yes | 132 | No |
X440A-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 132 | No |
X440B-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 132 | No |
X446B-R6 | 200GB | N/A | SSD | No | No | No | Yes | 132 | No |
X447A-R6 | 800GB | N/A | SSD | No | No | No | Yes | 132 | No |
DS4246 with IOM12 / IOM12 / IOM12B / IOM6 / IOM6 / IOM12B shelf modules | |||||||||
X302A-R5 | 1TB | 7.2K | SATA | No | Yes | No | No | 132 | No |
X306A-R5 | 2TB | 7.2K | SATA | No | Yes | No | No | 132 | No |
X308A-R5 | 3TB | 7.2K | SATA | No | Yes | No | No | 132 | No |
X309A-R6 [1] [2] | 3TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 132 | No |
X315A-R6 [1] [2] | 4TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 132 | No |
X316A-R6 | 6TB | 7.2K | NL-SAS | No | Yes | No | No | 132 | No |
X317A [1] | 6TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 132 | No |
X318A-R6 | 8TB | 7.2K | NL-SAS | No | Yes | No | No | 132 | No |
X322A [1] | 10TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 132 | No |
X336A-R6 | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 132 | No |
X363A-R6 | 3.84TB | N/A | SSD | No | No | No | Yes | 132 | No |
X366A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 132 | No |
X374A | 960GB | N/A | SSD | No | No | No | Yes | 132 | No |
X380A | 10TB | 7.2K | NL-SAS | No | Yes | No | No | 132 | No |
X441A-R5 | 100GB | N/A | SSD | No | No | No | No | 132 | No |
X448A-R6 | 200GB | N/A | SSD | No | No | No | Yes | 132 | No |
X449A-R6 | 800GB | N/A | SSD | No | No | No | Yes | 132 | No |
X477A-R6 | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 132 | No |
X488A-R5 | 900GB | 10K | SAS | No | Yes | No | No | 132 | No |
X489A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 132 | No |
X490A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 132 | No |
X575A-R6 | 400GB | N/A | SSD | No | No | No | Yes | 132 | No |
X576A-R6 | 1.6TB | N/A | SSD | No | No | No | Yes | 132 | No |
DS4243 [3] with IOM12 / IOM6 shelf modules | |||||||||
X302A-R5 | 1TB | 7.2K | SATA | No | No | No | No | 132 | No |
X306A-R5 | 2TB | 7.2K | SATA | No | No | No | No | 132 | No |
X308A-R5 | 3TB | 7.2K | SATA | No | No | No | No | 132 | No |
Footnote: | |||||||||
[1] Mixing NSE drives or shelves with any other type of encrypting or non-encrypting drives or shelves across a stand-alone platform or high-availability (HA) pair is not supported. | |||||||||
[2] In Flash Pool NSE SSD drives can only be used with NSE HDD drives. | |||||||||
[3] The DS4243 shelf requires an upgrade to IOM6 or IOM12 Expander Modules starting with ONTAP 9.4RC1 and FAS27x0. |
Supported RAID Configurations - FAS2720 2-Port UTA2 Single Chassis HA Pair
Drive Type | Drive Capacity Min | Drive Capacity Max | Minimum | Default | Maximum | ||||
---|---|---|---|---|---|---|---|---|---|
Data Aggregate | |||||||||
RAID4 | |||||||||
NL-SAS | 0 TB | 8 TB | 3 | 7 | 7 | ||||
SAS | 0 TB | 5.999 TB | 3 | 8 | 14 | ||||
SATA | 0 TB | 5.999 TB | 3 | 7 | 7 | ||||
SSD | 0 TB | 15.3 TB | 3 | 8 | 14 | ||||
RAID-DP | |||||||||
NL-SAS | 0 TB | 5.999 TB | 5 | 14 | 20 | ||||
NL-SAS | 6 TB | 10 TB | 5 | 14 | 14 | ||||
SAS | 0 TB | 5.999 TB | 5 | 16 | 28 | ||||
SATA | 0 TB | 5.999 TB | 5 | 14 | 20 | ||||
SSD | 0 TB | 15.3 TB | 5 | 24 | 28 | ||||
RAID-TEC | |||||||||
NL-SAS | 0 TB | 16 TB | 7 | 21 | 29 | ||||
SAS | 0 TB | 8 TB | 7 | 24 | 29 | ||||
SATA | 0 TB | 8 TB | 7 | 21 | 29 | ||||
SSD | 0 TB | 15.3 TB | 7 | 25 | 29 | ||||
Root Aggregate | |||||||||
RAID-DP | |||||||||
NL-SAS | 0 TB | 5.999 TB | 3 | 20 | |||||
NL-SAS | 6 TB | 16 TB | 3[1] | 14 | |||||
SAS | 0 TB | 5.999 TB | 3[2] | 28 | |||||
SATA | 0 TB | 5.999 TB | 3[2] | 20 | |||||
SSD | 0 TB | 15.3 TB | 3 | 28 | |||||
RAID-TEC | |||||||||
NL-SAS | 0 TB | 16 TB | 7 | 29 | |||||
SAS | 0 TB | 8 TB | 7 | 29 | |||||
SATA | 0 TB | 8 TB | 7 | 29 | |||||
SSD | 0 TB | 15.3 TB | 7 | 29 | |||||
Footnote: | |||||||||
1RAID-DP is supported with 10TB NL-SAS drives only if HA pair has 10-14 drives | |||||||||
2The minimum number of disks in a RAID-DP group is three: at least one data disk, one regular parity disk, and one double-parity (dParity) disk. However, for non-root aggregates with only one RAID group, you must have at least 5 disks (three data disks and two parity disks). |
Supported Adapter Cards - FAS2720 2-Port UTA2 Single Chassis HA Pair
Priority | Category | Bus Type | Mktg Part No. | Mfg Part No | Description | Plug Type | Optical Module Included? | Cables | Supported Protocol(s) | Min ONTAP | Max Qty [1] | Priority Slot Assignment | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Performance Acceleration | M.2 PCIe | X3311A | - | 111-03066 | Flash Cache,1.0TB,NVMe | No | N/A | 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | ||||||||||
Footnote: | |||||||||||||||||||
[1] Values shown for max quantity are per controller. HA configurations will support 2x the values shown. |
Supported Connections for FAS2720 2-Port UTA2 Single Chassis HA Pair
Configuration Type | Port Configuration | Image | Cluster Ports per Node | Switch Ports per Node | |||||
---|---|---|---|---|---|---|---|---|---|
Cluster Interconnect | |||||||||
2-node Switchless Cluster (option 1) | Default | View Image Above | 2 | None | |||||
2-node Switchless Cluster (option 2) | UTA2 ports e0c/e0d | View Image Above | 2 | None | |||||
2-node Switchless Cluster (option 3) | UTA2 ports e0e/e0f | View Image Above | 2 | None | |||||
Switched 10GbE Interconnect | Default, Recommended | View Image Above | 2 | 2 | |||||
Switched 40GbE Interconnect (10GbE breakout) | Default, Recommended | View Image Above | 2 | 1 |
Platform Mixing Rules - FAS2720 2-Port UTA2 Single Chassis HA Pair
Platform Configuration Type | Maximum Nodes (NAS) [1] | Maximum Nodes (SAN) [1] | Min ONTAP Version for Platform Mixing | ||||||
---|---|---|---|---|---|---|---|---|---|
FAS - Current Configuration(s) | |||||||||
FAS2720A 10GBASE-T | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
FAS2720A UTA2 | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
FAS2750A 10GBASE-T | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
FAS2750A UTA2 | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
FAS500fA | 24 Nodes | 12 Nodes | 9.8RC1 | ||||||
FAS8300A Ethernet Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS8300A FC Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS8700A Ethernet Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS8700A FC Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS9000A | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
FAS9500A | 24 Nodes | 12 Nodes | 9.10.1P3 | ||||||
AllFlashFAS - Current Configuration(s) | |||||||||
AFF A250A | 24 Nodes | 12 Nodes | 9.8RC1 | ||||||
AFF A250A 100V | 24 Nodes | 12 Nodes | 9.8P4 | ||||||
AFF A400A Ethernet Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF A400A FC Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF A700A | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
AFF A800A | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
AFF A900A | 24 Nodes | 12 Nodes | 9.10.1 | ||||||
AFF C190A 10GBASE-T | 24 Nodes | 12 Nodes | 9.6RC2 | ||||||
AFF C190A UTA2 | 24 Nodes | 12 Nodes | 9.6RC2 | ||||||
FAS - Legacy EOA Configuration(s) | |||||||||
FAS8200A | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
AllFlashFAS - Legacy EOA Configuration(s) | |||||||||
AFF A220A 10GBASE-T | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
AFF A220A UTA2 | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
AFF A300A | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
AFF A320A | 24 Nodes | 12 Nodes | 9.6RC2 | ||||||
AFF A700s | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
Footnote: | |||||||||
1Maximum number of nodes within a cluster is determined by platform which supports the fewest number of nodes |
Product Standard Compliance - FAS2720 2-Port UTA2 Single Chassis HA Pair
Standard | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|
Certifications EMC/EMI | |||||||||
AMCA | Australia and New Zealand (EMC covered by ACMA DoC) | ||||||||
FCC | Federal Communications Commission (EMI Declaration of Conformity covering United States and Canada) | ||||||||
ICES | ICES | ||||||||
KC | Korea Communications Commission (EMC certificate for South Korea) | ||||||||
Morocco | Morocco Declaration of Conformity | ||||||||
VCCI | EMI Certificate for Japan | ||||||||
Certifications safety | |||||||||
BIS | Bureau of Indian Standard (Safety cert for India) | ||||||||
CB | Certificate Body issued safety certificate covering International | ||||||||
CSA | Canadian Standards Association issued Safety certificate covering North America | ||||||||
G_K_U-SoR | Safety certificate for Gabon, Kenya and Uganda | ||||||||
IRAM | Instituto Argentino de Normalización y Certificación (safety certificate for Argentina) | ||||||||
NOM | Norma Oficial Mexicana (Safety cert for Mexico) | ||||||||
NRCS | National Regulator for Compulsory Specifications (Safety cert for South Africa) | ||||||||
SONCAP | Standards Organisation of Nigeria Conformity Assessment Programme (Safety cert for Nigeria) | ||||||||
TBS | Tanzanian Bureau of Standards (Safety certificate for Tanzania) | ||||||||
Certifications Safety/EMC/EMI | |||||||||
EAC | Euro Asia Conformity (EMC and Safety Cert) covering (Russia, Kazakhstan, Belarus, Armenia, Kyrgyzstan Countries) | ||||||||
UKRSEPRO | EMC/Safety certificate for Ukraine | ||||||||
Certifications Safety/EMC/EMI/RoHS | |||||||||
BSMI | Certificate for Taiwan | ||||||||
CE DoC | European Union Declaration of Conformity | ||||||||
UKCA DoC | UK Declaration of Conformity | ||||||||
Standards EMC/EMI | |||||||||
BS-EN-55024 | EMC standard for Great Britain | ||||||||
BS-EN55035 | EMC standard for Great Britain | ||||||||
CISPR 32 | EMI | ||||||||
EN55022 | EMC Standard fo European Union | ||||||||
EN55024 | EMC Standard fo European Union | ||||||||
EN55032 | EMI Standard fo European Union | ||||||||
EN55035 | EMC Standard for European Union | ||||||||
EN61000-3-2 | EMC Standard for European Union | ||||||||
EN61000-3-3 | EMC Standard for European Union | ||||||||
FCC Part 15 Class A | EMI standard for United States | ||||||||
ICES-003 | EMI Standard for Canada | ||||||||
KS C 9832 | EMI Standard for South Korea | ||||||||
KS C 9835 | EMC Standard for South Korea | ||||||||
Standards Safety | |||||||||
ANSI/UL60950-1 | Safety standard for United States | ||||||||
ANSI/UL62368-1 | Safety standard for United States | ||||||||
BS-EN62368-1 | Safety standard for Great Britain | ||||||||
CAN/CSA C22.2 No. 60950-1 | Safety Standard for Canada | ||||||||
CAN/CSA C22.2 No. 62368-1 | Safety Standard for Canada | ||||||||
CNS 14336 | Safety Standard for Taiwan | ||||||||
EN60825-1 | Laser Safety standard for European Union | ||||||||
EN62368-1 | Safety standard for European Union | ||||||||
IEC 62368-1 | Safety Standard for International | ||||||||
IEC60950-1 | Safety standard for International | ||||||||
IS 13252(part 1) | Safety Standard for India |
Supported OS Version - FAS2720 2-Port UTA2 Single Chassis HA Pair
OS Major Version | Supported OS Version | Supported Milestones | Recommend Version | ||||||
---|---|---|---|---|---|---|---|---|---|
Currently Supported OS | |||||||||
ONTAP 9.11.1 | 9.11.1, 9.11.1RC1 | End of Full Support: 31-Jul-2025 End of Limited Support: 31-Jul-2027 End of Self-Service Support: 31-Jul-2030 | 9.11.1 | ||||||
ONTAP 9.10.1 | 9.10.1P5, 9.10.1P6, 9.10.1P4, 9.10.1P3, 9.10.1P2, 9.10.1P1, 9.10.1, 9.10.1RC1 | End of Full Support: 31-Jan-2025 End of Limited Support: 31-Jan-2027 End of Self-Service Support: 31-Jan-2030 | 9.10.1P6 | ||||||
ONTAP 9.9.1 | 9.9.1P10, 9.9.1P9, 9.9.1P8, 9.9.1P7, 9.9.1P6, 9.9.1P5, 9.9.1P4, 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 | End of Full Support: 30-Jun-2024 End of Limited Support: 30-Jun-2026 End of Self-Service Support: 30-Jun-2029 | 9.9.1P10, 9.9.1P9 | ||||||
ONTAP 9.8 | 9.8P13, 9.8P12, 9.8P11, 9.8P10, 9.8P9, 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4, 9.8P3, 9.8P2, 9.8P1, 9.8, 9.8RC1 | End of Full Support: 31-Dec-2023 End of Limited Support: 31-Dec-2025 End of Self-Service Support: 31-Dec-2028 | 9.8P13, 9.8P12 | ||||||
ONTAP 9.7 | 9.7P19, 9.7P18, 9.7P17, 9.7P16, 9.7P15, 9.7P14, 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 | End of Full Support: 31-Jan-2023 End of Limited Support: 31-Jan-2025 End of Self-Service Support: 31-Jan-2028 | 9.7P19 | ||||||
EOS OS | |||||||||
ONTAP 9.7 | 9.7P19, 9.7P18, 9.7P17, 9.7P16, 9.7P15, 9.7P14, 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 | End of Full Support: 31-Jan-2023 End of Limited Support: 31-Jan-2025 End of Self-Service Support: 31-Jan-2028 | 9.7P19 | ||||||
ONTAP 9.6 | 9.6P18, 9.6P17, 9.6P16, 9.6P15, 9.6P14, 9.6P13, 9.6P12, 9.6P11, 9.6P10, 9.6P9, 9.6P8, 9.6P7, 9.6P6, 9.6P5, 9.6P4, 9.6P3, 9.6P2, 9.6P1, 9.6, 9.6RC2, 9.6RC1 | End of Full Support: 30-Jun-2022 End of Limited Support: 30-Jun-2024 End of Self-Service Support: 30-Jun-2027 | 9.6P18 | ||||||
ONTAP 9.5 | 9.5P19, 9.5P18, 9.5P17, 9.5P16, 9.5P15, 9.5P14, 9.5P13, 9.5P12, 9.5P11, 9.5P10, 9.5P9, 9.5P8, 9.5P7, 9.5P6, 9.5P5, 9.5P4, 9.5P3, 9.5P2, 9.5P1, 9.5, 9.5RC1 | End of Full Support: 31-Jan-2022 End of Limited Support: 31-Jan-2024 End of Self-Service Support: 31-Jan-2027 | 9.5P19 | ||||||
Definitions: | |||||||||
[1]End of Full Support: The date marking the end of Full Support for a particular feature version of a NetApp system software and the beginning of Limited Support. Abbreviated as EOES. | |||||||||
[2]End of Limited Support: The date marking the end of Limited Support for a particular feature version of a product and transition to Self-Service Support. Abbreviated as EOVS. | |||||||||
[3]End of Self-Service Support: NetApp does not provide support for a version of a software product, but related documentation is still available on the NetApp Support Site. NetApp customers are expected to utilize documentation to resolve issues. |
Supported Power Cords for FAS2720 2-Port UTA2 Single Chassis HA Pair
Marketing Part No. | End 1 / End 2 | Length | Description | |
---|---|---|---|---|
Non-Cabinet Power Cords | ||||
X-50617-00 | IEC60320-C20 / IEC60320-C13 | 2.00 m | Power Cords,In-Cabinet,2m,C20-C13,E-Series | |
X800B-R6 | CEE 7/7 (Schuko) / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Cont Europe/Korea,10A/250V | |
X800C-R6 | BS1363 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,UK/Ireland,10A/250V | |
X800D-R6 | JIS-C-8303 / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,Japan,15A/125V | |
X800E-R6 | NEMA 5-15P / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,North America,15A/125V | |
X800F-R6 | AS/NZS 3112 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Aus/NZ,10A/250V | |
X800G-R6 | SEV 1011 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Switzerland,10A/250V | |
X800H-R6 | IRAM 2073 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Argentina,10A/250V | |
X800I-R6 | GB2099 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,China,10A/250V | |
X800J-R6 | DHCR107-2-D1 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Demark,10A/250V | |
X800K-R6 | SANS 164-1 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,India/S.Africa,10A/250V | |
X800L-R6 | SI32 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Israel,10A/250V | |
X800M-R6 | CEI 23-16 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Italy,10A/250V | |
X800N | EL208 / IEC60320-C13 | 2.50 m | Pwr Cord,10A,250V,2.5m,India | |
X800P-R6 | NEMA 6-15P / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,North America,15A/250V | |
X800T-R6 | CNS 10917-3 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Taiwan,BSMI,15A/125V | |
X800VB-R6 | NBR14136 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Brazil,10A/250V | |
X800W-R6 | CNS10917/CNS690 / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,Taiwan,10A/250V | |
X800Y-R6 | JIS-C-830 / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,Japan,15A/250V | |
In-Cabinet Power Cords | ||||
X-50617-00-0E-C | IEC60320-C13 / IEC60320-C20 | 1.83 m | Power Cord,In-Cabinet,2m,C20-C13,E-Series,0E,-C | |
X1558A-R6 | IEC60320-C14 / IEC60320-C13 | 1.20 m | Pwr Cord,In-Cabinet,48-In,C13-C14,10A/250V | |
X800-42U-35 | IEC60320-C14 / IEC60320-C13 | 0.89 m | Pwr Cord,In-Cabinet,C13-C14,35-inch | |
X800-42U-43 | IEC60320-C14 / IEC60320-C13 | 1.09 m | Pwr Cord,In-Cabinet,C13-C14,43-inch | |
X800-42U-64 | IEC60320-C14 / IEC60320-C13 | 1.63 m | Pwr Cord,In-Cabinet,C13-C14,64-inch | |
X800-42U-R6 | IEC60320-C14 / IEC60320-C13 | 0.68 m | Pwr Cord,In-Cabinet,27-In,C13-C14,10A/250V |
Onboard Ports Configuration: FAS2720 2-Port UTA2 Single Chassis HA Pair
Port Address | Description | Supported Protocols | Port Icon | Port Type | |||||
---|---|---|---|---|---|---|---|---|---|
0a | Serial-Attached SCSI | SAS 6/12 Gb | Circle | MiniSAS HD | |||||
0b | Serial-Attached SCSI | SAS 6/12 Gb | Square | MiniSAS HD | |||||
e0a | Ethernet | Ethernet 10Gb | Ethernet | SFP+ | |||||
e0b | Ethernet | Ethernet 10Gb | Ethernet | SFP+ | |||||
e0c/0c [1] | Unified Target Adapter 2 | Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb | Ethernet/Fibre Channel | SFP+ | |||||
e0d/0d [1] | Unified Target Adapter 2 | Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb | Ethernet/Fibre Channel | SFP+ | |||||
e0m/BMC | Management | Ethernet 10/100/1000 Mb | Wrench | RJ45 | |||||
Serial Interface | USB Serial Console | RS-232 115200bps | USB 2.0 | USB 2.0 Micro-B | |||||
Serial Interface Icon | Serial Console | RS-232 115200bps | Serial Interface | RJ45 | |||||
USB/2 | Storage Host Port | USB 2.0 | USB 2.0 | USB Type A | |||||
Footnote: | |||||||||
1Connecting tape drives or tape libraries to the FC or UTA2 ports requires the use of a FC switch. |
Supported Platform Configurations - FAS2720 2-Port UTA2 Single Chassis HA Pair
Platform Configuration | Description | Chassis Configuration | Chassis Count | Controller Count (per chassis) | IOXM Count (per chassis) | Rack Units (Per System) | Weight (Per Chassis) | Min ONTAP | |
---|---|---|---|---|---|---|---|---|---|
HA Pair | |||||||||
FAS2720A 10GBASE-T | FAS2720 10GBASE-T Single Chassis HA Pair | CC | 1 | 2 | 0 | 2 | 41.23 lb (18.7 kg) | 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS2720A 2-port UTA2 | FAS2720A 2-port UTA2 | CC | 1 | 2 | 0 | 2 | 41.23 lb (18.7 kg) | 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS2720A UTA2 | FAS2720 UTA2 Single Chassis HA Pair | CC | 1 | 2 | 0 | 2 | 41.23 lb (18.7 kg) | 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 |
Platform Memory Specifications - FAS2720 2-Port UTA2 Single Chassis HA Pair
Part Number | Description | Mfg Part Number | Non-Volatile | Qty | Capacity (GB) | NVRAM/NVMEM Used Capacity (GB) | RAM Used Capacity (GB) |
---|---|---|---|---|---|---|---|
X3222A | R7,IC,SODIMM,16GB,x8,ECC,REG | 107-00172 | no | 4 | 16 | 8 | 64 |
Supported Rail Kit for FAS2720 2-Port UTA2 Single Chassis HA Pair
Marketing Part No. | Manufacturing Part No. | Description | |
---|---|---|---|
Third-Party Cabinet Rail Kits | |||
X-02654-00 | 111-02852 | Kit,2-Post, Thin | |
X-02657-00 | 111-02657 | Kit,4-Post,Thin,Rnd/Sq-Hole, 24"-32" Rail |
Supported Firmware Matrix - FAS2720 2-Port UTA2 Single Chassis HA Pair
Major OS Version | OS Version | Firmeware | |||||||
---|---|---|---|---|---|---|---|---|---|
BIOS | |||||||||
ONTAP 9.11.1 | 9.11.1 | 11.15* | |||||||
ONTAP 9.11.1 | 9.11.1RC1 | 11.16, 11.15* | |||||||
ONTAP 9.10.1 | 9.10.1P5-P6 | 11.16, 11.15* | |||||||
ONTAP 9.10.1 | 9.10.1P3-P4, 9.10.1P2, 9.10.1P1 | 11.16, 11.15, 11.13* | |||||||
ONTAP 9.10.1 | 9.10.1, 9.10.1RC1 | 11.16, 11.15, 11.13, 11.11* | |||||||
ONTAP 9.9.1 | 9.9.1P10 | 11.16, 11.15* | |||||||
ONTAP 9.9.1 | 9.9.1P8-P9, 9.9.1P7 | 11.16, 11.15, 11.13* | |||||||
ONTAP 9.9.1 | 9.9.1P4-P6, 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 | 11.16, 11.15, 11.13, 11.11* | |||||||
ONTAP 9.8 | 9.8P13 | 11.16, 11.15* | |||||||
ONTAP 9.8 | 9.8P11-P12 | 11.16, 11.15, 11.13* | |||||||
ONTAP 9.8 | 9.8P10, 9.8P9, 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4 | 11.16, 11.15, 11.13, 11.11* | |||||||
ONTAP 9.8 | 9.8P3, 9.8P2, 9.8P1, 9.8, 9.8RC1 | 11.16, 11.15, 11.13, 11.11, 11.9* | |||||||
ONTAP 9.7 | 9.7P19, 9.7P17-P18, 9.7P16, 9.7P15, 9.7P14 | 11.16, 11.15, 11.13, 11.11* | |||||||
ONTAP 9.7 | 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8 | 11.16, 11.15, 11.13, 11.11, 11.9* | |||||||
ONTAP 9.7 | 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7* | |||||||
ONTAP 9.6 | 9.6P18, 9.6P17, 9.6P16, 9.6P15 | 11.16, 11.15, 11.13, 11.11* | |||||||
ONTAP 9.6 | 9.6P13-P14, 9.6P12 | 11.16, 11.15, 11.13, 11.11, 11.9* | |||||||
ONTAP 9.6 | 9.6P10-P11 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7* | |||||||
ONTAP 9.6 | 9.6P9, 9.6P7-P8, 9.6P5-P6, 9.6P4, 9.6P3 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5* | |||||||
ONTAP 9.6 | 9.6P2, 9.6, 9.6P1, 9.6RC2, 9.6RC1 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5* | |||||||
ONTAP 9.5 | 9.5P19, 9.5P18 | 11.16, 11.15, 11.13, 11.11* | |||||||
ONTAP 9.5 | 9.5P17, 9.5P16, 9.5P15 | 11.16, 11.15, 11.13, 11.11, 11.9* | |||||||
ONTAP 9.5 | 9.5P14 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7* | |||||||
ONTAP 9.5 | 9.5P13, 9.5P12, 9.5P10-P11, 9.5P9, 9.5P8, 9.5P7, 9.5P6, 9.5P5, 9.5P4, 9.5P2-P3, 9.5P1, 9.5, 9.5RC1 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4* | |||||||
ONTAP 9.4 | 9.4P8, 9.4P7, 9.4P6, 9.4P5, 9.4P4, 9.4P3, 9.4P2, 9.4P1 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4, 11.2.1* | |||||||
ONTAP 9.4 | 9.4, 9.4RC1 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4, 11.2.1, 11.2* | |||||||
BMC | |||||||||
ONTAP 9.11.1 | 9.11.1, 9.11.1RC1 | 11.8* | |||||||
ONTAP 9.10.1 | 9.10.1P5-P6 | 11.8* | |||||||
ONTAP 9.10.1 | 9.10.1P3-P4, 9.10.1P2, 9.10.1P1, 9.10.1, 9.10.1RC1 | 11.8, 11.7* | |||||||
ONTAP 9.9.1 | 9.9.1P10, 9.9.1P8-P9, 9.9.1P7, 9.9.1P4-P6 | 11.8, 11.7* | |||||||
ONTAP 9.9.1 | 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 | 11.8, 11.7, 11.6* | |||||||
ONTAP 9.8 | 9.8P13 | 11.8* | |||||||
ONTAP 9.8 | 9.8P11-P12, 9.8P10, 9.8P9, 9.8P8 | 11.8, 11.7* | |||||||
ONTAP 9.8 | 9.8P7, 9.8P6, 9.8P5, 9.8P4, 9.8P3 | 11.8, 11.7, 11.6* | |||||||
ONTAP 9.8 | 9.8P2, 9.8P1 | 11.8, 11.7, 11.6, 11.5P1* | |||||||
ONTAP 9.8 | 9.8, 9.8RC1 | 11.8, 11.7, 11.6, 11.5P1, 11.5* | |||||||
ONTAP 9.7 | 9.7P19, 9.7P17-P18 | 11.8, 11.7* | |||||||
ONTAP 9.7 | 9.7P16, 9.7P15, 9.7P14, 9.7P13 | 11.8, 11.7, 11.6* | |||||||
ONTAP 9.7 | 9.7P12, 9.7P11 | 11.8, 11.7, 11.6, 11.5P1* | |||||||
ONTAP 9.7 | 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6 | 11.8, 11.7, 11.6, 11.5P1, 11.5* | |||||||
ONTAP 9.7 | 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4* | |||||||
ONTAP 9.6 | 9.6P18, 9.6P17 | 11.8, 11.7* | |||||||
ONTAP 9.6 | 9.6P16, 9.6P15 | 11.8, 11.7, 11.6* | |||||||
ONTAP 9.6 | 9.6P13-P14 | 11.8, 11.7, 11.6, 11.5P1* | |||||||
ONTAP 9.6 | 9.6P12, 9.6P10-P11 | 11.8, 11.7, 11.6, 11.5P1, 11.5* | |||||||
ONTAP 9.6 | 9.6P9, 9.6P7-P8, 9.6P5-P6 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4* | |||||||
ONTAP 9.6 | 9.6P4, 9.6P3 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2* | |||||||
ONTAP 9.6 | 9.6P2 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1* | |||||||
ONTAP 9.6 | 9.6, 9.6P1, 9.6RC2, 9.6RC1 | 11.8, 11.7, 11.6, 11.5P1, 11.5*, 11.4, 11.3P2, 11.3P1* | |||||||
ONTAP 9.5 | 9.5P19 | 11.8, 11.7* | |||||||
ONTAP 9.5 | 9.5P18 | 11.8, 11.7, 11.6* | |||||||
ONTAP 9.5 | 9.5P17, 9.5P16 | 11.8, 11.7, 11.6, 11.5P1* | |||||||
ONTAP 9.5 | 9.5P15, 9.5P14 | 11.8, 11.7, 11.6, 11.5P1, 11.5* | |||||||
ONTAP 9.5 | 9.5P13, 9.5P12, 9.5P10-P11 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4* | |||||||
ONTAP 9.5 | 9.5P9, 9.5P8, 9.5P7 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2* | |||||||
ONTAP 9.5 | 9.5P6 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1* | |||||||
ONTAP 9.5 | 9.5P5, 9.5P4, 9.5P2-P3, 9.5P1, 9.5, 9.5RC1 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.2* | |||||||
ONTAP 9.4 | 9.4P8 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1* | |||||||
ONTAP 9.4 | 9.4P7, 9.4P6, 9.4P5, 9.4P4, 9.4P3 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.1P3* | |||||||
ONTAP 9.4 | 9.4P2 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.1P3, 11.1P2* | |||||||
ONTAP 9.4 | 9.4P1, 9.4, 9.4RC1 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.1P3, 11.1P2, 11.1* | |||||||
Footnote: | |||||||||
[1]* Indicates that firmware is bundled with Storage OS Version |
Product Certificates - FAS2720 UTA2 Single Chassis HA Pair
Certificate Name | Geo / Region / Country | Associated Products | |||||||
---|---|---|---|---|---|---|---|---|---|
Battery Pack safety reports | |||||||||
Lithium Battery Safety Doc-Section II/Section IB Shipments,Inventus Power Product Model#271-00045AWB | Global | Platforms : AFF A220, AFF A320, AFF A400, AFF A700s, AFF A800, AFF C190, FAS2620, FAS2650, FAS2720, FAS2750, FAS8300, FAS8700 | |||||||
EMI and Safety certificates | |||||||||
Declaraion of Similarity NAJ-1502 | Global | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 G-K-U-SoR | Gabon,Kenya,SaudiArabia,Uganda | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 (FXN Taiwan) BIS | BIS - India | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 (Jabil Mexico) BIS | BIS - India | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 (Jabil Singapore) BIS | BIS - India | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 60950-CB | CB - International | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 62368-CB | CB - International | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 ACMA | ACMA - Australia, New Zealand | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 BSMI | BSMI - Taiwan | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 CSA | CSA - United States, Canada | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 DoC CE | CE - European Union DoC | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 EAC | EAC - Armenia, Belarus, Kazakhstan, Kyrgyzstan, Russia | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 IRAM | IRAM - Argentina | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 KC | KC - South Korea | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 Morocco | Morocco | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 NOM | NOM - Mexico | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 NRCS | NRCS - South Africa (Safety) | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 SONCAP | SONCAP - Nigeria | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 TBS | TBS - Tanzania | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 UKRSep | Global | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 VCCI | VCCI - Japan | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 FCC | FCC - United States | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
NAJ-1502 UKCA DOC | UKCA -United Kingdom | Platforms : E2812, FAS2620, FAS2720, SG5712 | |||||||
PSU 80+ Platinum Certificates | |||||||||
DCJ9133-01 Energy Star Report | Global | Platforms : AFF A220, AFF C190, ASA AFF A220, FAS2720, FAS2750 | |||||||
TDPS-900AB A Energy Star Report | Global | Platforms : AFF A220, AFF C190, ASA AFF A220, FAS2720, FAS2750 | |||||||
Voluntary Product Accessibility Template | |||||||||
VPAT - NetApp Accessibility Conformance Report - NetApp FAS2720 | Global | Platforms : FAS2720 |
Size, Weight, Acoustic, Power FAS2720 2-Port UTA2 Single Chassis HA Pair
Associated Part No. | Configuration | Rack Units | Weight | Sound Power | Sound Pressure | Line Voltage Actual (Min to Max) | Amps Typical | Amps Worst | Watts Typical | Watts Worst | BTU / Hr Typical | BTU / Hr Worst |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Embedded Drive Config (Empty) | ||||||||||||
FAS2720-100-C | FAS2720 2 PCM no drives | 2 | 41.2 lb (18.7 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 2.53 | 3.42 | 247 | 335 | 843 | 1144 |
FAS2720-100-C | FAS2720 2 PCM no drives | 2 | 41.2 lb (18.7 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 1.24 | 1.68 | 243 | 329 | 830 | 1123 |
Embedded Drive Config (Full) | ||||||||||||
FAS2720-101-C | FAS2720 2 PCM 12x2TB NL-SAS | 2 | 59.1 lb (26.8 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 3.65 | 4.55 | 357 | 445 | 1219 | 1519 |
FAS2720-101-C | FAS2720 2 PCM 12x2TB NL-SAS | 2 | 59.1 lb (26.8 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 1.79 | 2.23 | 350 | 437 | 1195 | 1492 |
FAS2720-102-C | FAS2720 2 PCM 12x4TB | 2 | 61.1 lb (27.7 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 4.14 | 5.04 | 405 | 493 | 1383 | 1683 |
FAS2720-102-C | FAS2720 2 PCM 12x4TB | 2 | 61.1 lb (27.7 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 2.03 | 2.47 | 397 | 484 | 1355 | 1652 |
FAS2720-102-C | FAS2720 2 PCM 12x4TB NSE | 2 | 61.1 lb (27.7 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 4.14 | 5.04 | 405 | 493 | 1383 | 1683 |
FAS2720-102-C | FAS2720 2 PCM 12x4TB NSE | 2 | 61.1 lb (27.7 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 2.03 | 2.47 | 397 | 484 | 1355 | 1652 |
FAS2720-103-C | FAS2720 2 PCM 12x8TB | 2 | 63.5 lb (28.8 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 4.18 | 5.07 | 409 | 496 | 1396 | 1693 |
FAS2720-103-C | FAS2720 2 PCM 12x8TB | 2 | 63.5 lb (28.8 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 2.05 | 2.49 | 401 | 487 | 1369 | 1663 |
FAS2720-104-C | FAS2720 2 PCM 12x10TB | 2 | 60.4 lb (27.4 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 3.92 | 4.82 | 384 | 472 | 1311 | 1611 |
FAS2720-104-C | FAS2720 2 PCM 12x10TB | 2 | 60.4 lb (27.4 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 1.93 | 2.37 | 377 | 463 | 1287 | 1581 |
FAS2720-104-C | FAS2720 2 PCM 12x10TB NSE | 2 | 60.4 lb (27.4 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 3.92 | 4.82 | 384 | 472 | 1311 | 1611 |
FAS2720-104-C | FAS2720 2 PCM 12x10TB NSE | 2 | 60.4 lb (27.4 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 1.93 | 2.37 | 377 | 463 | 1287 | 1581 |
FAS2720-105-C | FAS2720 2 PCM 12x10TB | 2 | 60.4 lb (27.4 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 3.92 | 4.82 | 384 | 472 | 1311 | 1611 |
FAS2720-105-C | FAS2720 2 PCM 12x10TB | 2 | 60.4 lb (27.4 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 1.93 | 2.37 | 377 | 463 | 1287 | 1581 |
FAS2720-105-C | FAS2720 2 PCM 12x10TB NSE | 2 | 60.4 lb (27.4 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 3.92 | 4.82 | 384 | 472 | 1311 | 1611 |
FAS2720-105-C | FAS2720 2 PCM 12x10TB NSE | 2 | 60.4 lb (27.4 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 1.93 | 2.37 | 377 | 463 | 1287 | 1581 |
FAS2720-115-C | FAS2720 2 PCM 12x16TB NL-SAS | 2 | 60.6 lb (27.5 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 3.89 | 4.79 | 381 | 469 | 1301 | 1601 |
FAS2720-115-C | FAS2720 2 PCM 12x16TB NL-SAS | 2 | 60.6 lb (27.5 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 1.91 | 2.35 | 374 | 460 | 1277 | 1570 |
Embedded Drive Config (Mixed) | ||||||||||||
FAS2720-106-C | FAS2720 2 PCM 4x960GB, 8x2TB | 2 | 55.1 lb (25.0 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 3.8 | 4.7 | 372 | 460 | 1270 | 1570 |
FAS2720-106-C | FAS2720 2 PCM 4x960GB, 8x2TB | 2 | 55.1 lb (25.0 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 1.87 | 2.31 | 365 | 451 | 1246 | 1540 |
FAS2720-107-C | FAS2720 2 PCM 4x960GB, 8x4TB | 2 | 56.4 lb (25.6 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 4.05 | 4.94 | 396 | 484 | 1352 | 1652 |
FAS2720-107-C | FAS2720 2 PCM 4x960GB, 8x4TB | 2 | 56.4 lb (25.6 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 1.99 | 2.43 | 389 | 475 | 1328 | 1622 |
FAS2720-108-C | FAS2720 2 PCM 4x960GB, 8x8TB | 2 | 58.0 lb (26.3 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 4.07 | 4.96 | 398 | 486 | 1359 | 1659 |
FAS2720-108-C | FAS2720 2 PCM 4x960GB, 8x8TB | 2 | 58.0 lb (26.3 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 2 | 2.44 | 391 | 477 | 1335 | 1628 |
FAS2720-109-C | FAS2720 2 PCM 4x960GB, 8x10TB | 2 | 56.0 lb (25.4 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 3.9 | 4.8 | 382 | 470 | 1304 | 1605 |
FAS2720-109-C | FAS2720 2 PCM 4x960GB, 8x10TB | 2 | 56.0 lb (25.4 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 1.92 | 2.36 | 375 | 461 | 1280 | 1574 |
FAS2720-111-C | FAS2720 2 PCM 4x3.8TB, 8x4TB | 2 | 56.4 lb (25.6 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 4.08 | 4.97 | 399 | 487 | 1362 | 1663 |
FAS2720-111-C | FAS2720 2 PCM 4x3.8TB, 8x4TB | 2 | 56.4 lb (25.6 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 2 | 2.44 | 392 | 478 | 1338 | 1632 |
FAS2720-112-C | FAS2720 2 PCM 4x3.8TB, 8x8TB | 2 | 58.0 lb (26.3 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 4.11 | 5 | 402 | 490 | 1372 | 1673 |
FAS2720-112-C | FAS2720 2 PCM 4x3.8TB, 8x8TB | 2 | 58.0 lb (26.3 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 2.02 | 2.46 | 394 | 481 | 1345 | 1642 |
FAS2720-116-C | FAS2720 2 PCM 4x960GB, 8x16TB | 2 | 54.9 lb (24.9 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 3.63 | 4.53 | 355 | 443 | 1212 | 1512 |
FAS2720-116-C | FAS2720 2 PCM 4x960GB, 8x16TB | 2 | 54.9 lb (24.9 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 1.78 | 2.22 | 348 | 435 | 1188 | 1485 |
FAS2720-117-C | FAS2720 2 PCM 4x3.8TB, 8x16TB | 2 | 54.9 lb (24.9 kg) | 6.7 Bels | 51 dBA | 100 (100 to 120) | 3.63 | 4.53 | 355 | 443 | 1212 | 1512 |
FAS2720-117-C | FAS2720 2 PCM 4x3.8TB, 8x16TB | 2 | 54.9 lb (24.9 kg) | 6.7 Bels | 51 dBA | 200 (200 to 240) | 1.78 | 2.22 | 348 | 435 | 1188 | 1485 |