Base Standard Capabilities
Capability / Features | Description | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Chassis | One rack unit (1RU) chassis | |||||||||||||||||||||||||||
CPU | One or two Intel® Xeon E5-2600 v3 or v4 series processor family CPUs | |||||||||||||||||||||||||||
Chipset | Intel® C610 series chipset | |||||||||||||||||||||||||||
Memory | 24 slots for registered DIMMs (RDIMMs) or load-reduced DIMMs (LRDIMMs) | |||||||||||||||||||||||||||
Multi-bit Error Protection | This server supports multi-bit error protection. | |||||||||||||||||||||||||||
Embedded NIC | Two embedded (on the motherboard) Intel i350 GbE ports, supporting the following:
| |||||||||||||||||||||||||||
Expansion slots |
| |||||||||||||||||||||||||||
Cisco Flexible Flash drives | The server supports up to two internal 32 GB or two internal 64 GB Cisco Flexible Flash drives (SD cards). The second SD card is blank and can be used to mirror the first SD card. It can be used to protect the Hypervisor Partition with RAID1. | |||||||||||||||||||||||||||
Internal storage devices | Drives are installed into front-panel drive bays that provide hot-pluggable access.
UCS Storage Accelerators are also available. These PCIe flash storage devices provide independent high-speed storage. | |||||||||||||||||||||||||||
Video | The Cisco Integrated Management Controller (CIMC) provides video using the Matrox G200e video/graphics controller:
| |||||||||||||||||||||||||||
Interfaces | Rear panel
| |||||||||||||||||||||||||||
Storage controller | Embedded Software RAID (6 Gbps)
Cisco 12 Gbps Modular SAS HBA with internal SAS connectivity
Supported RAID Levels: JBOD only Cisco 9300-8E 12G SAS HBA with external SAS connectivity
| |||||||||||||||||||||||||||
WoL | The 1-Gb Base-T Ethernet LAN ports support the wake-on-LAN (WoL) standard. | |||||||||||||||||||||||||||
Front Panel | A front panel controller provides status indications and control buttons | |||||||||||||||||||||||||||
Modular LAN on Motherboard (mLOM) slot | The mLOM slot can flexibly accommodate the following cards:
| |||||||||||||||||||||||||||
Power subsystem | Up to two 770 W (AC) hot swappable power supplies or two 1050 W (DC) power supplies. One is mandatory; one more can be added for 1 + 1 redundancy. | |||||||||||||||||||||||||||
ACPI | This server supports the advanced configuration and power interface (ACPI) 4.0 standard. | |||||||||||||||||||||||||||
Fans | Six hot-swappable fans for front-to-rear cooling | |||||||||||||||||||||||||||
Integrated management processor | Baseboard Management Controller (BMC) running Cisco Integrated Management Controller (CIMC) firmware. Depending on your CIMC settings, the CIMC can be accessed through the 1-GbE dedicated management port, the 1-GbE LOM ports, or a Cisco virtual interface card (VIC). | |||||||||||||||||||||||||||
Notes | The drives are available as both self-encrypted drives (SED) and non self-encrypted drives. |
Available CPU's
Product ID (PID) | Intel Number | Clock Freq (GHz) | Power (W) | Cache Size (MB) | Cores | QPI | Highest DDR4 DIMM Clock Support (MHz) [1] | |||
---|---|---|---|---|---|---|---|---|---|---|
UCS-CPU-E52699AE | E5-2699A v4 | 2.4 | 145 | 55 | 22 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52699E | E5-2699 v4 | 2.2 | 145 | 55 | 22 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52698E | E5-2698 v4 | 2.2 | 135 | 50 | 20 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52697AE | E5-2697A v4 | 2.6 | 145 | 40 | 16 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52697E | E5-2697 v4 | 2.3 | 145 | 45 | 18 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52695E | E5-2695 v4 | 2.1 | 120 | 45 | 18 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52690E | E5-2690 v4 | 2.6 | 135 | 35 | 14 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52683E | E5-2683 v4 | 2.1 | 120 | 40 | 16 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52680E | E5-2680 v4 | 2.4 | 120 | 35 | 14 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52667E | E5-2667 v4 | 3.2 | 135 | 25 | 8 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52660E | E5-2660 v4 | 2 | 105 | 35 | 14 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52650E | E5-2650 v4 | 2.2 | 105 | 30 | 12 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52650LE | E5-2650L v4 | 1.7 | 65 | 35 | 14 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52643E | E5-2643 v4 | 3.4 | 135 | 20 | 6 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52640E | E5-2640 v4 | 2.4 | 90 | 25 | 10 | 8.0 GT/s | 2133 | |||
UCS-CPU-E52637E | E5-2637 v4 | 3.5 | 135 | 15 | 4 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52630E | E5-2630 v4 | 2.2 | 85 | 25 | 10 | 8.0 GT/s | 2133 | |||
UCS-CPU-E52630LE | E5-2630L v4 | 1.8 | 55 | 25 | 10 | 8.0 GT/s | 2133 | |||
UCS-CPU-E52623E | E5-2623 v4 | 2.6 | 85 | 10 | 4 | 8.0 GT/s | 2133 | |||
UCS-CPU-E52620E | E5-2620 v4 | 2.1 | 85 | 20 | 8 | 8.0 GT/s | 2133 | |||
UCS-CPU-E52609E | E5-2609 v4 | 1.7 | 85 | 20 | 8 | 6.4 GT/s | 1866 | |||
UCS-CPU-E52658E | E5-2658 v4 | 2.3 | 105 | 35 | 14 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52680D | E5-2680 v3 | 2.5 | 120 | 30 | 12 | 8.0 GT/s | 2133 | |||
UCS-CPU-E52640D | E5-2640 v3 | 2.6 | 90 | 20 | 8 | 6.4 GT/s | 1866 | |||
UCS-CPU-E52620D | E5-2620 v3 | 2.4 | 85 | 15 | 6 | 6.4 GT/s | 1866 | |||
UCS-CPU-E52609D | E5-2609 v3 | 1.9 | 85 | 15 | 6 | - | 1600 | |||
UCS-CPU-E52658D | E5-2658 v3 | 2.2 | 105 | 30 | 12 | 8.0 GT/s | 2133 | |||
Footnote: | ||||||||||
[1] | If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock | |||||||||
[1] | You can select either one processor or two identical processors. | |||||||||
[2] | For optimal performance, select DIMMs with the highest clock speed for a given processor |
Available DIMMs and Memory Mirroring
Product ID (PID) | PID Description | Voltage | Ranks /DIMM | |||||||
---|---|---|---|---|---|---|---|---|---|---|
2400-MHz DIMM Options | ||||||||||
UCS-ML-1X644RV-A | 64GB DDR4-2400-MHz LRDIMM/PC4-19200/quad rank/x4 | 1.2 V | 4 | |||||||
UCS-ML-1X324RV-A | 32GB DDR4-2400-MHz LRDIMM/PC4-19200/quad rank/x4 | 1.2 V | 4 | |||||||
UCS-MR-1X322RV-A | 32GB DDR4-2400-MHz RDIMM/PC4-19200/dual rank/x4 | 1.2 V | 2 | |||||||
UCS-MR-1X162RV-A | 16GB DDR4-2400-MHz RDIMM/PC4-19200/dual rank/x4 | 1.2 V | 2 | |||||||
UCS-MR-1X161RV-A | 16GB DDR4-2400-MHz RDIMM/PC4-19200/single rank/x4 | 1.2 V | 1 | |||||||
UCS-MR-1X081RV-A | 8 GB DDR4-2400-MHz RDIMM/PC4-19200/single rank/x4 | 1.2 V | 1 | |||||||
Memory Mirroring Option | ||||||||||
N01-MMIRROR | Memory mirroring option | - | - | |||||||
Footnote: | ||||||||||
[1-CPU] | Without memory mirroring: Select from 1 to 12 DIMMs. | |||||||||
[1-CPU] | With memory mirroring: Select 2, 4, 8, or 12 identical DIMMs. | |||||||||
[2-CPU] | Without memory mirroring: Select from 1 to 12 DIMMs. | |||||||||
[2-CPU] | With memory mirroring: Select 2, 4, 8, or 12 identical DIMMs. | |||||||||
[1] | System performance is optimized when the DIMM type and quantity are equal for both CPUs, and when all channels are filled equally across the CPUs in the server. | |||||||||
[2] | System speed is dependent on how many DIMMs are populated per channel and the CPU DIMM speed support. | |||||||||
[3] | When you mix 2400 MHz RDIMMs of different sizes (for example, 4x32GB + 4x16GB), the memory speed clocks one step down to 2133 MHz. | |||||||||
[4] | Do not mix RDIMMs with LRDIMMs | |||||||||
[5] | Do not mix 64GB DDR4-2133-MHz TSV-RDIMMs with any other DIMMs | |||||||||
[6] | Single-rank DIMMs can be mixed with dual-rank DIMMs in the same channel | |||||||||
[7] | Do not mix quad-rank DIMMs with single- or dual-rank DIMMs in the same channel | |||||||||
[8] | DIMMs for CPU 1 and CPU 2 (when populated) must always be configured identically. | |||||||||
[9] | When using mirroring, DIMMs must be installed in identical pairs across paired DDR4 buses. That is, mirrored pairs in channels A and B must be identical and pairs in channels C and D must be identical. However, the DIMMs used in channels A and B can be different from those in channels C and D. | |||||||||
[10] | Memory mirroring reduces the amount of available memory by 50% (quantity of DIMMs must be even for mirroring). | |||||||||
[11] | Non-ECC DIMMs are not supported. | |||||||||
[12] | Cisco memory from previous generation servers (DDR3) is not compatible with this server |
Available RAID Controllers:
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCSC-MRAID12G | Cisco 12G SAS Modular RAID Controller
| |||||||||
UCSC-SAS12GHBA | Cisco 12 Gbps Modular SAS HBA
| |||||||||
UCSC-PSAS12GHBA [1] | Same functionality as UCSC-SAS12GHBA, but vendor is Microsemi | |||||||||
UCSC-SAS9300-8E | Cisco 12G (non-RAID) SAS HBA with 8 external ports | |||||||||
UCSC-SWRAID5 | Software Raid 5 upgrade key for embedded Raid | |||||||||
Flash-Backed Write Cache (FBWC) Upgrade Options for Cisco 12G SAS Modular RAID controller | ||||||||||
UCSC-MRAID12G-512 | 512 MB FBWC, which includes a 512 MB memory plus a SuperCap for data cache power backup for the Cisco 12G SAS Modular RAID controller. Supports JBOD, RAID 0, 1, 5, and 50. | |||||||||
UCSC-MRAID12G-1GB | 1 GB FBWC, which includes a 1 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60. | |||||||||
UCSC-MRAID12G-2GB | 2 GB FBWC, which includes a 2 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60. | |||||||||
UCSC-MRAID12G-4GB | 4 GB FBWC, which includes a 4 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60. | |||||||||
SAS HBA for External JBOD Attach Two SFF8644 mini-SAS HD connectors on this card are accessible at the rear of the chassis. | ||||||||||
UCSC-SAS9300-8E | Cisco 9300-8e 12G SAS HBA for external JBOD attach Supports external JBOD using X8 wide SAS ports. | |||||||||
SuperCap Option | ||||||||||
UCSC-MRAID-SC= | Spare SuperCap for Cisco 12G SAS Modular RAID, including all cables. This is a spare SuperCap. It is the exact same SuperCap that ships with the FBWC options listed earlier in this table and can be used as a replacement or upgrade part. | |||||||||
RAID Configuration Options (not available for Cisco 12 Gbps Modular SAS HBA or embedded software RAID) | ||||||||||
R2XX-SRAID0 | Enable Single Disk Raid 0 Setting | |||||||||
R2XX-RAID0 | Factory preconfigured RAID striping option Enable RAID 0 Setting. Requires a minimum of one hard drive. | |||||||||
R2XX-RAID1 | Factory preconfigured RAID mirroring option Enable RAID 1 Setting. Requires exactly two drives with the same size, speed, capacity. | |||||||||
R2XX-RAID5 | Factory preconfigured RAID option Enable RAID 5 Setting. Requires a minimum of three drives of the same size, speed, capacity. | |||||||||
R2XX-RAID6 | Factory preconfigured RAID option Enable RAID 6 Setting. Requires a minimum of four drives of the same size, speed, capacity. | |||||||||
Footnote: | ||||||||||
[1] | Use the same capacity for each drive in each RAID volume | |||||||||
[2] | Embedded RAID = 8 | |||||||||
[3] | Cisco 12G SAS Modular RAID controller = 64 | |||||||||
[4] | Embedded software RAID (this is the default if no other selection is made) | |||||||||
[5] | The embedded software RAID default supports up to 8 internal SATA HDDs with RAID 0, 1, 10 support. | |||||||||
[6] | The Cisco 12G SAS Modular RAID controller upgrade option supports up to 8 internal drives with up to RAID 0, 1, 10, 5, 6, 50, 60 support (with FBWC option chosen). | |||||||||
[7] | The Cisco 12 Gbps Modular SAS HBA upgrade option supports up to 8 internal drives with JBOD support. | |||||||||
[8] | The Cisco 9300-8e 12G SAS HBA supports up to 8 external SAS ports with JBOD support. |
Available Drives
Product ID (PID) | Description | Drive Type | Speed | Size | ||||||
---|---|---|---|---|---|---|---|---|---|---|
HDDs (15K RPM) | ||||||||||
UCS-HD900G15K12G | 900 GB 12G SAS 15K RPM SFF HDD | SAS | 15K RPM | 900GB | ||||||
UCS-HD600G15K12G | 600 GB 12G SAS 15K RPM SFF HDD | SAS | 15K RPM | 600 GB | ||||||
UCS-HD450G15K12G | 450 GB 12G SAS 15K RPM SFF HDD | SAS | 15K RPM | 450 GB | ||||||
UCS-HD300G15K12G | 300 GB 12G SAS 15K RPM SFF HDD | SAS | 15K RPM | 300 GB | ||||||
HDDs (10K RPM) | ||||||||||
UCS-HD18TB10KS4K [1] | 1.8 TB 12 Gbps SAS 10K RPM SFF HDD (4K sector format) | SAS | 10K RPM | 1.8 TB | ||||||
UCS-HD12TB10K12G | 1.2 TB 12G SAS 10K RPM SFF HDD | SAS | 10K RPM | 1.2 TB | ||||||
UCS-HD900G10K12G | 900 GB 12G SAS 10K RPM SFF HDD | SAS | 10K RPM | 900 GB | ||||||
UCS-HD600G10K12G | 600 GB 12G SAS 10K RPM SFF HDD (Seagate) | SAS | 10K RPM | 600 GB | ||||||
UCS-HD300G10K12G | 300 GB 12G SAS 10K RPM SFF HDD | SAS | 10K RPM | 300 GB | ||||||
HDDs (7.2K RPM) | ||||||||||
UCS-HD2T7K12G | 2 TB 12G SAS 7.2K RPM SFF HDD | SAS | 7.2K RPM | 2 TB | ||||||
UCS-HD1T7K12GA | 1 TB 12G SAS 7.2K RPM SFF HDD | SAS | 7.2K RPM | 1 TB | ||||||
UCS-HD1T7K6GA | 1 TB 6G SATA 7.2K RPM SFF HDD | SATA | 7.2K RPM | 1 TB | ||||||
SSDs | ||||||||||
Enterprise Performance SSDs (High endurance, supports up to 10X or 3X DWPD (drive writes per day)) [2] | ||||||||||
UCS-SD16TB12S4-EP | 1.6 TB 2.5 inch Enterprise Performance 12G SAS SSD (10X DWPD) (Sandisk Lightning Ascend) | SAS | N/A | 1.6 TB | ||||||
UCS-SD400G12S4-EP | 400 GB 2.5 inch Enterprise Performance 12G SAS SSD (10X DWPD) (Sandisk Lightning Ascend) | SAS | N/A | 400 GB | ||||||
UCS-SD800G12S4-EP | 800 GB 2.5 inch Enterprise Performance 12G SAS SSD (10X DWPD) (Samsung 1635)) | SAS | N/A | 800 GB | ||||||
UCS-SD16TSASS3-EP | 1.6TB 2.5 inch Enterprise performance 12G SAS SSD (3X DWPD) | SAS | N/A | 1.6 TB | ||||||
UCS-SD800GSAS3-EP | 800 GB 2.5 inch Enterprise performance 12G SAS SSD (3X DWPD | SAS | N/A | 800 GB | ||||||
UCS-SD32TSASS3-EP | 3.2 TB 2.5 inch Enterprise performance 12G SAS SSD (3X DWPD) | SAS | N/A | 3.2 TB | ||||||
UCS-SD400GSAS3-EP | 400 GB 2.5 inch Enterprise performance 12G SAS SSD (3X DWPD) | SAS | N/A | 400 Gb | ||||||
UCS-SD480GIS3-EP | 480GB 2.5in Enterprise performance 6G SATA SSD (3X endurance) (Intel S4600) | SATA | N/A | 480 Gb | ||||||
UCS-SD960GIS3-EP | 960 GB 2.5in Enterprise performance 6G SATA SSD (3X endurance) (Intel S4600) | SATA | N/A | 960 Gb | ||||||
UCS-SD19TIS3-EP | 1.9 TB 2.5in Enterprise performance 6G SATA SSD (3X endurance) (Intel S4600) | SATA | N/A | 1.9 TB | ||||||
Enterprise Value SSDs (Low endurance, supports up to 1X DWPD (drive writes per day)) [3] | ||||||||||
UCS-SD38TBKS4-EV | 3.8TB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863) | SATA | - | 3.8 TB | ||||||
UCS-SD19TBKSS-EV | 1.9 TB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863) | SATA | - | 1.9 TB | ||||||
UCS-SD16TBKS4-EV | 1.6 TB 2.5 inch Enterprise Value 6G SATA SSD (Intel 3510) | SATA | - | 1.6 TB | ||||||
UCS-SD480GBKSS-EV | 480 GB 2.5 in Enterprise Value 6G SATA SSD (Samsung PM863) | SATA | - | 480 GB | ||||||
UCS-SD480GBKS4-EV | 480 GB 2.5 inch Enterprise Value 6G SATA SSD (Intel 3510) | SATA | - | 480 GB | ||||||
UCS-SD120GBKS4-EV | 120 GB 2.5 inch Enterprise Value 6G SATA SSD (Intel 3510) | SATA | - | 120 GB | ||||||
UCS-SD960GBKS4-EV | 960 GB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863) | SATA | - | 960 GB | ||||||
UCS-SD240GBKS4-EV | 240 GB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863) | SATA | - | 240 GB | ||||||
UCS-SD960GIKS4-EV | 960 GB 2.5 inch Enterprise Value 6G SATA SSD | SATA | - | 960 GB | ||||||
UCS-SD38TSAS-EV | 3.8 TB 2.5 inch Enterprise Value 12G SAS SSD | SAS | - | 3.8 TB | ||||||
UCS-SD19TSAS-EV | 1.9 TB 2.5 inch Enterprise Value 12G SAS SSD | SAS | - | 1.9 TB | ||||||
UCS-SD960GSAS-EV | 960 GB 2.5 inch Enterprise Value 12G SAS SSD | SAS | - | 960 GB | ||||||
UCS-SD480GSAS-EV | 480 GB 2.5 inch Enterprise Value 12G SAS SSD | SAS | - | 480 GB | ||||||
UCS-SD480GBIS6-EV | 480 GB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500) | SATA | - | 480 GB | ||||||
UCS-SD960GBIS6-EV | 960 GB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500) | SATA | - | 960 GB | ||||||
UCS-SD38TBIS6-EV | 3.8 TB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500) | SATA | - | 3.8 TB | ||||||
UCS-SD76TBMS4-EV | 7.6 TB 2.5 inch Enterprise Value 6G SATA SSD | SATA | - | 7.6 TB | ||||||
UCS-SD38TBMS4-EV | 3.8 TB 2.5 inch Enterprise Value 6G SATA SSD | SATA | - | 3.8 TB | ||||||
UCS-SD19TBMS4-EV | 1.9 TB 2.5 inch Enterprise Value 6G SATA SSD | SATA | - | 1.9 TB | ||||||
UCS-SD16TBMS4-EV | 1.6 TB 2.5 inch Enterprise Value 6G SATA SSD | SATA | - | 1.6 TB | ||||||
UCS-SD960GBMS4-EV | 960 GB 2.5 inch Enterprise Value 6G SATA SSD | SATA | - | 960 GB | ||||||
UCS-SD480GBMS4-EV | 480 GB 2.5 inch Enterprise Value 6G SATA SSD | SATA | - | 480 GB | ||||||
UCS-SD240GBMS4-EV | 240 GB 2.5 inch Enterprise Value 6G SATA SSD | SATA | - | 240 GB | ||||||
UCS-SD120GBMS4-EV | 120 GB 2.5 inch Enterprise Value 6G SATA SSD | SATA | - | 120 GB | ||||||
NVMe SFF 2.5” drives | ||||||||||
UCSC-NVMEM4-H800 | Cisco 2.5in U.2 800GB HGST SN200 NVMe. High Endurance SSD | NVMe | - | 800 GB | ||||||
UCSC-NVMEM4-H1600 | Cisco 2.5in U.2 1.6TB HGST SN200 NVMe. High Endurance SSD | NVMe | - | 1.6 TB | ||||||
C220 M4 NVMe SFF 2.5” drives riser card kit and cables | ||||||||||
UCSC-PCI-2B-220M4 | - | - | - | - | ||||||
Self-Encrypting HDDs and SSDs | ||||||||||
HDDs | ||||||||||
HDDs (15K RPM) | ||||||||||
UCS-HD600G15K9 | 600GB 12G SAS 15K RPM SFF HDD (SED) | SAS | - | 600 GB | ||||||
HDDs (10K RPM) | ||||||||||
UCS-HD18G10K9 [2] | 1.8TB 12G SAS 10K RPM SFF HDD (4K sector format, SED) | SAS | - | 1.8 TB | ||||||
UCS-HD12G10K9 | 1.2 TB 12G SAS 10K RPM SFF HDD (SED) | SAS | - | 1.2 TB | ||||||
UCS-HD300G10K9 | 300GB 12G SAS 10K RPM SFF HDD (SED) | SAS | - | 300 GB | ||||||
SSDs | ||||||||||
Enterprise Performance SSDs (High endurance, supports up to 10X or 3X DWPD (drive writes per day)) [2] | ||||||||||
UCS-SD16TBEK9 | 1.6 TB Enterprise performance SAS SSD (10X DWPD, SED) | SAS | - | 1.6 TB | ||||||
UCS-SD800GBEK9 | 800 GB Enterprise performance SAS SSD (10X DWPD, SED) | SAS | - | 800 GB | ||||||
UCS-SD400GBEK9 | 400 GB Enterprise performance SAS SSD (10X DWPD, SED) | SAS | - | 400 GB | ||||||
UCS-SD600GBE3K9 | 600 GB Enterprise performance SATA SSD (3X DWPD, SED) | SATA | - | 600 GB | ||||||
Enterprise Value SSDs (Low endurance, supports up to 1X DWPD (drive writes per day)) [3] | ||||||||||
UCS-SD960GBE1K9 | 960 GB Enterprise Value SATA SSD (1X DWPD, SED) | SATA | - | 960 GB | ||||||
UCS-SD480GBE1K9 | 480 GB Enterprise Value SATA SSD (1X DWPD, SED) | SATA | - | 480 GB | ||||||
UCS-SD120GBE1K9 | 120 GB Enterprise Value SATA SSD (1X DWPD) | SATA | - | 120 GB | ||||||
UCS-SD240GBM1K9 | 240 GB Enterprise Value SSD (SATA) (1X FWPD, SED) | SATA | - | 240 GB | ||||||
UCS-SD960GBM1K9 | 960 GB Enterprise Value SSD (SATA) (1X FWPD, SED) | SATA | - | 960 GB | ||||||
UCS-SD38TBM1K9 | 3.8 TB Enterprise Value SSD (SATA) (1X FWPD, SED) | SATA | - | 3.8 TB | ||||||
Footnote: | ||||||||||
[Notes:] | - | |||||||||
[1] | UCS Rack Servers require minimum firmware version 2.0(4) to support 4K sector size drives. | |||||||||
[2] | Targeted for write centric IO applications. Supports endurance of 10 or 3 DWPD (drive writes per day). Target applications are caching, online transaction processing (OLTP), data warehousing, and virtual desktop infrastructure (VDI). | |||||||||
[3] | Targeted for read centric IO applications. Supports endurance of 1 DWPD (drive writes per day). Target applications are boot, streaming media, and collaboration. | |||||||||
[4] | If you choose one or two PCIe SSD drives, drive slots 1 and 2 at the front of the chassis are reserved for these drives | |||||||||
[5] | You must order a riser card kit and cables if you order an NVMe SFF 2.5” drive. One riser card kit and cables supports up to two NVMe SFF 2.5” drives. | |||||||||
[Approved Configurations] | - | |||||||||
[1] | Embedded Software RAID Select up to eight SATA-only HDDs | |||||||||
[2] | Cisco 12G SAS Modular RAID Controller If you selected a Cisco 12G SAS Modular RAID controller you have the following options:
| |||||||||
[3] | Cisco 12 Gbps Modular SAS HBA If you selected a Cisco 12 Gbps Modular SAS HBA, select up to eight SAS HDDs or eight SAS/SATA SSDs. | |||||||||
[4] | Systems Using Plug-in NVMe SFF 2.5” drives Systems using NVMe SFF 2.5” drives are controlled through the PCIe bus. If you choose one or two NVMe SFF 2.5” drives they must be plugged into only drive slots 1 and 2 in the front of the chassis. Additionally, any system implementing NVMe SFF 2.5” drives must be ordered with two CPUs. | |||||||||
[Caveats] | - | |||||||||
[1] | You can choose only SATA HDDs when using embedded software RAID. | |||||||||
[2] | You can choose only SAS HDDs or SAS/SATA SSDs when using the Cisco 12G SAS Modular RAID Controller or Cisco 12 Gbps Modular SAS HBA. | |||||||||
[3] | You can mix HDDs and SSDs as long as you keep all HDDs in their own RAID volume and all SSDs in their own RAID volume. | |||||||||
[4] | You can mix SAS HDDs and SAS/SATA SSDs when using the Cisco 12G SAS Modular RAID Controller or Cisco 12 Gbps Modular SAS HBA. | |||||||||
[5] | If you order any NVMe SFF 2.5” drives, you must also order two CPUs. | |||||||||
[6] | A maximum of two NVMe SFF 2.5” drives can be ordered. | |||||||||
[7] | NVMe SFF 2.5"" drives are bootable only in standalone mode with IMC software and in UEFI mode only. | |||||||||
[8] | NVMe HHHL drives are not bootable. | |||||||||
[9] | NVMe SFF 2.5” drives cannot be controlled with a RAID controller | |||||||||
[10] | SED drives are compatible with only with the combination of a UCSC-MRAID12G RAID controller along with one of the flash-back write cache modules: UCSC-MRAID12G-1GB, — UCSC-MRAID12G-2GB, — UCSC-MRAID12G-4GB |
Available PCIe Option Cards
Product ID (PID) | PID Description | Card Height | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Modular LAN on Motherboard (mLOM) | ||||||||||
UCSC-MLOM-C10T-02 | Cisco UCS VIC1227T VIC MLOM - Dual Port 10GBaseT | N/A | ||||||||
UCSC-MLOM-CSC-02 | Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+ | N/A | ||||||||
UCSC-MLOM-IRJ45 | Intel i350 quad-port MLOM NIC | N/A | ||||||||
UCSC-MLOM-C40Q-03 | Cisco VIC 1387 Dual Port 40Gb QSFP CNA MLOM | N/A | ||||||||
Virtual Interface Cards (VICs) | ||||||||||
UCSC-PCIE-CSC-02 | Cisco VIC 1225 Dual Port 10Gb SFP+ CNA | Half | ||||||||
UCSC-PCIE-C10T-02 | Cisco VIC 1225T Dual Port 10GBaseT CNA | Half | ||||||||
UCSC-PCIE-C40Q-03 | Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA | Half | ||||||||
Network Interface Cards (NICs) | ||||||||||
1 Gb NICs | ||||||||||
UCSC-PCIE-IRJ45 | Intel i350 Quad Port 1Gb Adapter | Half | ||||||||
10 Gb NICs | ||||||||||
N2XX-AIPCI012 | Intel X520 Dual Port 10Gb SFP+ Adapter | Half | ||||||||
UCSC-PCIE-ITG | Intel X540 Dual Port 10GBase-T Adapter | Half | ||||||||
UCSC-PCIE-QNICBT | QLogic QLE8442 dual-port 10Gbase-T NIC | Half | ||||||||
UCSC-PCIE-QNICSFP | QLogic QLE8442 dual-port 10G SFP+ NIC | Half | ||||||||
UCSC-PCIE-ID10GF | Intel X710-DA2 dual-port 10G SFP+ NIC | Half | ||||||||
UCSC-PCIE-IQ10GF | Intel X710 quad-port 10G SFP+ NIC | Half | ||||||||
UCSC-PCIE-ID40GF | Intel XL710 dual-port 40G QSFP+ NIC | Half | ||||||||
10 Gb Converged Network Adapters (CNAs) | ||||||||||
UCSC-PCIE-E14102B | Emulex OCe14102B-UX dual-port 10G SFP+ with iSCSI, FCoE CNA | Half | ||||||||
UCSC-PCIE-E14102 | Emulex OCe14102-UX dual-port 10 GbE FCoE CNA | Half | ||||||||
UCSC-PCIE-Q8362 | Qlogic QLE8362 dual-port 10 GbE FCoE CNA | Half | ||||||||
Host Bus Adapters (HBAs) | ||||||||||
UCSC-PCIE-BS32GF | Broadcom LPe32000 Single-Port 32G FC HBA | Half | ||||||||
UCSC-PCIE-BD32GF | Broadcom LPe32002 Dual-Port 32G FC HBA | Half | ||||||||
UCSC-PCIE-QD32GF | Qlogic QLE2742 dual-port 32G FC HBA N2XX-AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA | Half | ||||||||
UCSC-PCIE-Q2672 | Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics N2XX-AEPCI05 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA | Half | ||||||||
UCSC-PCIE-E16002 | Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics | Half | ||||||||
UCS Storage Accelerators [3] | ||||||||||
UCSC-F-S13002 | UCS Rack PCIe Storage 1300 GB SanDisk SX350 Medium Endurance | Half | ||||||||
UCSC-F-S16002 | UCS Rack PCIe Storage 1600 GB SanDisk SX350 Medium Endurance | Half | ||||||||
UCSC-F-S32002 | UCS Rack PCIe Storage 3200 GB SanDisk SX350 Medium Endurance | Half | ||||||||
UCSC-F-S64002 | UCS Rack PCIe Storage 6400 GB SanDisk SX350 Medium Endurance | Full | ||||||||
UCS NVMe/PCie Add in Cards | ||||||||||
UCSC-F-H38001 | 3.8 TB NVMe/PCIe storage (HGST SN150) Read Intensive | Half | ||||||||
UCSC-NVME-H64003 | Cisco HHHL AIC 6.4T HGST SN260 NVMe Extreme Perf High Endurance | HHHL* | ||||||||
UCSC-NVME-H76801 | Cisco HHHL 7.7T HGST SN260 NVMe Extreme Perf Value Endurance | HHHL* | ||||||||
UCSC-NVME-H32003 | Cisco HHHL AIC 3.2T HGST SN260 NVMe Extreme Perf High Endurance | HHHL* | ||||||||
*HHHL= Half Height Half Length | ||||||||||
Footnote: | ||||||||||
[1] | The mLOM cards do not plug into any of the riser 1 or riser 2 card slots | |||||||||
[2] | The Intel X520 supports the following Cisco PIDs: UCS-SFP-1WLR and UCS-SFP-1WSR SFPs. Refer to the Intel X520 product brief for a full list of supported optics and cables | |||||||||
[3] | A maximum of two storage accelerator cards are supported if they are half height | |||||||||
[Approved Configurations] | - | |||||||||
[1-CPU Systems] | You can select up to one PCie option card (slot 1 for 1-CPU systems) | |||||||||
[2-CPU Systems] | You can select up to two PCie option cards (slots 1 and 2 for 2-CPU systems) | |||||||||
[Caveats] | - | |||||||||
[1] | A maximum of two storage accelerator cards are supported if they are half height | |||||||||
[2] | For 1-CPU systems: Only the full-height PCIe slot on riser 1 (slot 1) is supported — Only a single plug-in PCIe VIC card is supported and must be installed in slot 1 (the full-height slot). However, in addition to the one PCIe VIC card, you can also choose to install an mLOM VIC card. — If any of the Storage Accelerator cards are installed, they can be installed only in slot 1. | |||||||||
[3] | For 2-CPU systems: Both PCIe slots(slots 1 and 2) are supported — Two plug-in PCIe VIC cards can be installed in 2-CPU systems, using slots 1 and 2. In addition, you can order an mLOM VIC card, which is installed in the mLOM slot inside the chassis and thus have three VIC cards in operation at the same time. —If any of the Storage Accelerator cards are installed, they can be installed only in slot 1 |
Available Network Card Accessories (Optional)
Product ID(PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Available Twinax Cables | ||||||||||
SFP-H10GB-CU1M | 10GBASE-CU SFP+ Cable (1 M) | |||||||||
SFP-H10GB-CU3M | 10GBASE-CU SFP+ Cable (3 M) | |||||||||
SFP-H10GB-CU5M | 10GBASE-CU SFP+ Cable (5 M) | |||||||||
Available SFP Modules | ||||||||||
SFP-10G-SR | 10GBASE-SR SFP+ Module 850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring | |||||||||
SFP-10G-LR | 10GBASE-LR SFP+ Module 1310 nm, single mode, LR, 3.3 V, with Digital Optical Monitoring | |||||||||
DS-SFP-FC8G-SW | 8 Gbit SFP+ Module 850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring | |||||||||
Footnote: | ||||||||||
[Approved Configurations] | - | |||||||||
[1] | Choose Up to Two Twinax Cables for Each Network Card Ordered
You may choose one or two twinax cables for each compatible PCIe network card ordered. The cables can be different lengths | |||||||||
[2] | Choose Up to Two SFP+ Modules for Each Network Card Ordered
You may choose one or two SFP+ optical modules cables for each compatible PCIe network card ordered. You would normally order two modules for connecting to the primary and redundant network switching equipment. With the SFP+ optical modules, you can use common fiber optic cables, widely available. | |||||||||
[3] | Check the table on for compatibility between the PCIe network cards and SFPs or twinax cables at "PCIe Card Compatibility". |
Available Power Cords
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
R2XX-DMYMPWRCORD | No power cord (dummy PID to allow for a no power cord option) | |||||||||
CAB-N5K6A-NA | Power Cord, 200/240V 6A, North America | |||||||||
CAB-AC-L620-C13 | AC Power Cord, NEMA L6-20 - C13, 2M/6.5ft | |||||||||
CAB-C13-CBN | CABASY,WIRE,JUMPER CORD, 27" L, C13/C14, 10A/250V | |||||||||
CAB-C13-C14-2M | CABASY,WIRE,JUMPER CORD, PWR, 2 Meter, C13/C14,10A/250V | |||||||||
CAB-C13-C14-AC | CORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M | |||||||||
CAB-250V-10A-AR | Power Cord, 250V, 10A, Argentina 186571 2500 mm Cordset rating: 10 A, 250/500 V MAX Length: 8.2 ft Plug: EL 219 (IRAM 2073) Connector: EL 701 (IEC60320/C13) | |||||||||
CAB-9K10A-AU | Power Cord, 250VAC 10A 3112 Plug, Australia Plug: Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm 186580 Connector: EL 701C EL 210 (EN 60320/C15) (BS 1363A) 13 AMP fuse | |||||||||
CAB-250V-10A-CN | AC Power Cord - 250V, 10A - PRC | |||||||||
CAB-9K10A-EU | Power Cord, 250VAC 10A CEE 7/7 Plug, EU Connector: VSCC15 Cordset rating: 10A/16 A, 250 V Length: 8 ft 2 in. (2.5 m) Plug: M2511 186576 | |||||||||
CAB-9K10A-IT | Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy Plug: I/3G (CEI 23-16) Connector C15M (EN60320/C15 ) Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) 186575 | |||||||||
CAB-9K10A-SW | Power Cord, 250VAC 10A MP232 Plug, Switzerland Plug: MP232-R Cordset rating: 10 A, 250 V Length: 8 ft. 2 in (2.5 m) 186578 Connector: IEC 60320 C15 | |||||||||
CAB-9K10A-UK | Power Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK | |||||||||
CAB-9K12A-NA | Power Cord, 125VAC 13A NEMA 5-15 Plug, North America | |||||||||
CAB-250V-10A-BR | Power Cord - 250V, 10A - Brazil | |||||||||
CAB-48DC-40A-8AWG | Power Cord for -48VDC PSU, 3.5M, 3 Wire, 8AWG, 4 | |||||||||
CAB-JPN-3PIN | Power Cord 3PIN, Japan | |||||||||
CAB-C13-C14-2M-JP | Power Cord C13-C14, 2M/6.5ft Japan PSE mark | |||||||||
CAB-250V-10A-IS | AC Power Cord - 250V, 10A - Israel | |||||||||
CAB-250V-10A-ID | AC Power Cord - 250V, 10A, India |
Available NIC Mode (Optional)
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCSC-DLOM-01 | Dedicated Mode BIOS setting for C-Series Servers | |||||||||
UCSC-CCARD-01 | Cisco Card Mode BIOS setting for C-Series Servers | |||||||||
Footnote: | ||||||||||
[1] | By default, the C220 M4 server NIC mode is configured to be Shared LOM Extended. This NIC mode allows any LOM port or adapter card port to be used to access the Cisco Integrated Management Controller (CIMC). The Cisco VIC card must be installed in a slot with NCSI support. | |||||||||
[2] | To change the default NIC mode to Dedicated, select the UCSC-DLOM-01 PID shown in Table Above. In Dedicated NIC mode, the CIMC can be accessed only through the dedicated management port. | |||||||||
[3] | To change the default NIC mode to Cisco Card Mode, select the UCSC-CCARD-01 PID shown in Table Above. In this mode, you can assign an IP address to the CIMC using DHCP and from there you can fully automate your deployment. |
PCIe Card Compatibility
PCIe Cards | Twinax Cables | Cisco SFP Modules | ||
---|---|---|---|---|
SFP-10G-SR | SFP-10G-LR | DS-SFP-FC8G-SW | ||
Converged Network Adapters (CNAs) | ||||
UCSC-PCIE-BSFP (Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI) | Yes | Yes | No | |
UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA) | Yes | Yes | Yes | No |
UCSC-PCIE-C10T-02 (Cisco VIC 1225T Dual Port 10GBaseT CNA) | No | No | No | No |
UCSC-MLOM-CSC-02 (Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+) | Yes | Yes | Yes | No |
UCSC-MLOM-C10T-02 (Cisco UCS VIC1227T VIC MLOM - Dual Port 10GBaseT) | No | No | No | No |
UCSC-PCIE-C40Q-02 (Cisco VIC 1285 Dual Port 40Gb QSFP CNA) | Yes | No [1] | No | |
UCSC-PCIE-C40Q-03 (Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA) | Yes | No [1] | No | |
UCSC-PCIE-ESFP (Emulex OCe11102-FX dual-port 10 GbE FCoE CNA (Gen 3 CNA)) | Yes | Yes | No | |
UCSC-PCIE-QSFP (QLogic QLE8242-CU dual-port 10 GbE FCoE CNA) | Yes | Use Qlogic SFP | ||
UCSC-PCIE-B3SFP (Broadcom 57810 10Gb A-FEX SFP+ | Yes | Yes | No | |
UCSC-PCIE-Q8362 (Qlogic QLE8362 dual-port 10 GbE FCoE CNA) | Yes | Use Qlogic SFP | ||
UCSC-PCIE-E14102 (Emulex OCe14102-UX dual-port 10 GbE FCoE CNA) | Yes | Yes | No | |
Converged Network Adapters (CNAs) | ||||
N2XX-ABPCI01-M3 (Broadcom 5709 Dual-Port Ethernet PCIe Adapter for M3 Servers) | Use RJ45 Ethernet cable | |||
N2XX-ABPCI03-M3 (Broadcom 5709 Quad Port 10/100/1Gb NIC w/TOE iSCSI for M3 Servers | Use RJ45 Ethernet cable | |||
N2XX-AIPCI01 (Intel X520 Dual Port 10Gb SFP+ Adapter) | Yes | Use Intel SFP UCS-SFP-1WLR or UCS-SFP-1WSR | ||
UCSC-PCIE-ITG (Intel X540 Dual Port 10GBase-T Adapter) | Use RJ45 Ethernet cable | |||
UCSC-PCIE-IRJ45 (Intel i350 Quad Port 1Gb Adapter | Use RJ45 Ethernet cable | |||
UCSC-PCIE-IRJ45 (Intel i350 Quad Port 1Gb Adapter | Yes | No | No | |
Host Bus Adapters (HBAs) | ||||
N2XX-AEPCI03 (Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA | No | Preinstalled - do not change SFP | ||
N2XX-AEPCI05 (Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA) | No | Preinstalled - do not change SFP | ||
N2XX-AQPCI03 (QLogic QLE2462 Dual Port 4Gb Fibre Channel HBA) | No | Preinstalled - do not change SFP | ||
N2XX-AQPCI05 (QLogic QLE2562 Dual Port 8Gb Fibre Channel HBA) | No | Preinstalled - do not change SFP | ||
UCSC-PCIE-Q2672 (Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics) | No | Preinstalled - do not change SFP | ||
UCSC-PCIE-E16002 (Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics) | No | Preinstalled - do not change SFP | ||
Footnotes: | ||||
[1] | This card supports a 4x10 Gbps QSFP to SFP breakout fiber cable. |