Please remove $0 item(s) from cart - or - Request for Quote

Cisco UCS C220 C-Series M4 4x 3.5" LFF Rack Servers CTO

Brand:
Type:
CTO Servers
Condition:
ECS Refurbished & Tested
-PLEASE CONTACT FOR CUSTOM CONFIGURATIONS. DISK SHELVES, COMPLETE CONFIGURATIONS & TURN KEY SYSTEMS AVAILABLE.
-SPARE PARTS AVAILABLE FOR EACH MODEL. PLEASE ASK FOR PRICING ON SPARE DISK, CONTROLLERS, POWER SUPPLIES, NICs, HBAs, SFPs, Cables, etc.

READ ME

  • Some options may not be displayed until the compatible parent option is chosen ie. Chassis – Drives, Processor – RAM etc.
  • “Submit for Quote” items can be added to your cart and sent to us via the cart page
  • Click the blue bar to close/open a section from view after choosing your options

Select Chassis

Does not include power supply, CPU, memory, hard disk drives (HDDs), SD cards, rail kit, plug-in PCIe cards.

Intel E5-2600 Processor Family

You can select either one processor or two identical processors

E5-2600 v4 Series Processor Family CPU

Select Security Bezel (Optional)

An optional locking bezel can be mounted to the front of the chassis to prevent unauthorized access to the drives.

Select Memory

Memory is organized with four memory channels per CPU, with up to three DIMMs per channel
More Detail Below

Select Memory Mode (Optional)

Select RAID Controllers (Optional)

For more details on RAID Controllers. Please look below.

Select HDD Drives (Optional)

You must select either a HDD or SSD drive.
3.5-inch large form factor Hot-pluggable Drives come mounted in sleds
Self-encrypting drives (SED) at bottom of list

Select SSD Drives (Optional)

You must select either and HDD or SSD drive.
3.5-inch large form factor Hot-pluggable Drives come mounted in sleds
Self-encrypting drives (SED) at bottom of list

Select PCIe Option Card(s) (Optional)

For more information, please read below.

Select Network Card Accessories (Optional)

Choose Up to Two Twinax Cables for Each Network Card Ordered
Choose Up to Two SFP+ Modules for Each Network Card Ordered

Select Power Supplies

The C220 M4 LFF server accommodates two power supplies.

Select Power Cable(s) (Optional)

You can select a minimum of no power cords and a maximum of two.

Select Rail Kit (Optional)

Select Cable Management Arm (CMA) (Optional)

Select NIC Mode (Optional)

Select Trusted Platform Module (TPM) (Optional)

Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server).

Select Flash SD Card Module (Optional)

Install either one or two 64, or 32 GB SD cards
Do not mix SD card sizes

Select USB 3.0 Drive (Optional)

You can order one optional USB 3.0 drive.

Select Warranty

Helpful Tip: Once desired configuration is selected click "Add to Cart". From the cart page you can submit a submit a quote request for best pricing

The Cisco® UCS C220 M4 LFF rack server is the newest 2-socket, 1U rack server from Cisco, designed for both performance and expandability over a wide range of storage-intensive infrastructure workloads from web serving to distributed database.

The enterprise-class UFCS C220 M4 LFF server extends the capabilities of Cisco’s Unified Computing System portfolio in a 1U form factor with the addition of the Intel Xeon E5-2600 v3 and v4 series processor family that deliver significant performance and efficiency gains. In addition, the UCS C220 M4 SFF server provides 24 DIMM slots, up to 4 drives and 2 x 1 GbE LAN-on-motherboard (LOM) ports delivering outstanding levels of density and performance in a compact 1U package.

The C220 M4 SFF server includes a modular LAN on motherboard (mLOM) slot for installation of a Cisco Virtual Interface Card (VIC) or third-party network interface card (NIC) without consuming a PCI slot in addition to 2 x 1 GbE embedded (on the motherboard) LOM ports. These features combine to provide outstanding levels of internal memory and storage expandability along with exceptional performance.

The Cisco UCS C240 M4 LFF server can be used standalone, or as part of the Cisco Unified Computing System, which unifies computing, networking, management, virtualization, and storage access into a single integrated architecture enabling end-to-end server visibility, management, and control in both bare metal and virtualized environments.

 

Current Configuration

Select Chassis

Intel E5-2600 Processor Family

Select Security Bezel (Optional)

Select Memory

Select Memory Mode (Optional)

Select RAID Controllers (Optional)

Select HDD Drives (Optional)

Select SSD Drives (Optional)

Select PCIe Option Card(s) (Optional)

Select Network Card Accessories (Optional)

Select Power Supplies

Select Power Cable(s) (Optional)

Select Rail Kit (Optional)

Select Cable Management Arm (CMA) (Optional)

Select NIC Mode (Optional)

Select Trusted Platform Module (TPM) (Optional)

Select Flash SD Card Module (Optional)

Select USB 3.0 Drive (Optional)

Select Warranty

*list also serves as quick links to each section

Welcome to the Request Express Quoting Form!

for: Cisco UCS C220 C-Series M4 4x 3.5" LFF Rack Servers CTO


This streamlined form is designed to simplify the quoting process for you. Whether you're uncertain about specific parts or seeking a hassle-free experience, you're in the right place.

Provide us with the necessary details, and we'll generate a customized quote for your server. Even if you're unsure about the exact components you need, we've got you covered. Our team will tailor a solution based on the information you provide.

Let's get started!
Simply fill out the form, and we'll take care of the rest.


Name *
Email *
Message *
Preferred Brand
Form Factor
Rack Unit of Height (#U)
Processor(s)
Memory
Total Amount of Memory
Total Amount of Usable Storage

Storage Type


RAID

List Networking Connection needed:
Rack Space Restrictions
Which OS do you plan on using:


Price as Configured: 0

Add to Cart

Error Submitting Cart. Please get in touch with us for support.

Please select all the mandatory items in the configuration list before submitting the cart.

One or more items in your cart has no price. This will be submitted as a "Request for a Quote".

Product Specs

Base Standard Capabilities

Capability / FeatureDescription
ChassisOne rack unit (1RU) chassis
CPUOne or two Intel® Xeon E5-2600 v3 or v4 series processor family CPUs
ChipsetIntel® C610 series chipset
Memory24 slots for DDR4 registered DIMMs (RDIMMs) or load-reduced DIMMs (LRDIMMs)
Multi-bit Error ProtectionThis server supports multi-bit error protection.
Embedded NICTwo embedded (on the motherboard) Intel i350 GbE ports, supporting the following:
  • Pre-Execution Boot (PXE boot)
  • iSCSI boot
  • Checksum and segmentation offload
  • NIC teaming
Expansion slots
  • Riser 1 (controlled by CPU 1):
    • One full-height profile, 3/4-length slot with x24 connector and x16 lane
  • Riser 2 (controlled by CPU 2):
    • One half-height profile, half-length slot with x24 connector and x16 lane, or
  • Dedicated Cisco 12G SAS Modular RAID controller slot
    • An internal slot is dedicated for the 12G SAS Modular RAID controller card.
Internal storage devicesDrives are installed into front-panel drive bays that provide hot-pluggable access.
• Large Form Factor (LFF) drives. Up to four 3.5-inch SAS hot-swappable hard disk drives (HDDs)1.
  • The server also contains one internal USB 3.0 port on the motherboard that you can use with a an optional 16 GB USB thumb drive for additional storage
  • UCS Storage Accelerators are also available. These PCIe flash storage devices provide independent high-speed storage.
Cisco Flexible Flash drivesThe server supports up to two internal 32 GB or two internal 64 GB Cisco Flexible Flash drives (SD cards).
The second SD card is blank and can be used to mirror the first SD card. It can be used to protect the Hypervisor Partition with RAID1.
VideoThe Cisco Integrated Management Controller (CIMC) provides video using the Matrox G200e video/graphics controller:
  • Integrated 2D graphics core with hardware acceleration
  • DDR2/3 memory interface supports up to 512 MB of addressable memory (8 MB is allocated by default to video memory)
  • Supports display resolutions up to 1920 x 1200 16bpp @ 60Hz
  • High-speed integrated 24-bit RAMDAC
  • Single lane PCI-Express host interface running at Gen 1 speed
Interfaces
  • Rear panel
    • One DB15 VGA connector
    • One RJ45 serial port connector
    • Two USB 3.0 port connectors
    • One RJ-45 10/100/1000 Ethernet management port, using Cisco Integrated Management Controller (CIMC) firmware
    • Two Intel i350 embedded (on the motherboard) GbE LOM ports
    • One flexible modular LAN on motherboard (mLOM) slot that can accommodate various interface cards
  • Front panel
    • One KVM console connector (supplies two USB 2.0 connectors, one VGA DB15 connector, and one serial port (RS232) RJ45 connector)
  • Various PCIe card ports (dependent on which cards are installed)
    • Virtual Interface Card (VIC) ports
    • Converged Network Adapter (CNA) ports
    • Network Interface Card (NIC) ports
    • Host Bus Adapter (HBA) ports
Storage controllerCisco 12G SAS Modular RAID controller card with internal SAS connectivity.
  • Supports up to 24 internal drives (note however that this server can be configured with a maximum of 4 drives)
  • Plugs into a dedicated RAID controller slot
  • Can be purchased alone, or along with an onboard Flash-Backed Write Cache (FBWC) upgrade option, as shown in the table below
Notes
RAID Card VersionSupported RAID LevelsOnboard TMM Cache
UCSC-MRAID12G [1]JBOD, 0, 1, 10None
UCSC-MRAID12G-512 [2]JBOD, 0, 1, 5, 50512 MB
UCSC-MRAID12G-1GB [2]JBOD, 0, 1, 10, 5, 6, 50, 601 GB
UCSC-MRAID12G-2GB [2]JBOD, 0, 1, 10, 5, 6, 50, 602 GB
UCSC-MRAID12G-4GB [2]JBOD, 0, 1, 10, 5, 6, 50, 604 GB
Base RAID controller card (RAID 0, 1, 10 only)
FBWC option for base RAID controller card (adding the FBWC option extends the RAID levels)
Cisco 12 Gbps Modular SAS HBA with internal SAS connectivity
  • Supports up to 24 internal drives (only 4 drives supported in this server)
  • Plugs into a dedicated PCIe slot at the rear of the server (slot 1 of riser 1)
  • Supports JBOD only, not RAID, as shown in the below table.
HBA Card VersionSupported RAID Levels
UCSC-SAS12GHBAJBOD only
Cisco 9300-8E 12G SAS HBA with external SAS connectivity
  • Provides 8 external SAS ports
  • Plugs into a PCIe slot at the rear of the server
  • No FBWC (cache) or cache power backup
  • SAS 3.0 compliant
Modular LAN on Motherboard (mLOM) slotThe mLOM slot can flexibly accommodate the following cards:
  • Cisco Virtual Interface Cards (VIC)
  • Quad Port Intel i350 1GbE RJ45 Network Interface Card (NIC)
NOTE: The four Intel i350 ports are provided on an optional card that plugs into the mLOM slot, and are separate from the two embedded (on the motherboard) LAN ports
WoLThe 1-Gb Base-T Ethernet LAN ports support the wake-on-LAN (WoL) standard.
Front PanelA front panel controller provides status indications and control buttons
Power subsystemUp to two 770 W (AC) hot swappable power supplies or two 1050 W (DC) power supplies. One is mandatory; one more can be added for 1 + 1 redundancy.
ACPIThis server supports the advanced configuration and power interface (ACPI) 4.0 standard.
FansChassis: Six hot-swappable fans for front-to-rear cooling
Integrated management processorBaseboard Management Controller (BMC) running Cisco Integrated Management Controller (CIMC) firmware.
Depending on your CIMC settings, the CIMC can be accessed through the 1-GbE dedicated management port, the 1-GbE LOM ports, or a Cisco virtual interface card (VIC).
Notes
1. The drives are available as both self-encrypted drives (SED) and non self-encrypted drives.

Available CPU's

Product ID (PID) Intel Number Clock Freq (GHz) Power (W) Cache Size (MB) Cores QPI Highest DDR4 DIMM Clock Support (MHz) [1]
UCS-CPU-E52699AE E5-2699A v4 2.4 145 55 22 9.6 GT/s 2400
UCS-CPU-E52699E E5-2699 v4 2.2 145 55 22 9.6 GT/s 2400
UCS-CPU-E52698E E5-2698 v4 2.2 135 50 20 9.6 GT/s 2400
UCS-CPU-E52697AE E5-2697A v4 2.6 145 40 16 9.6 GT/s 2400
UCS-CPU-E52697E E5-2697 v4 2.3 145 45 18 9.6 GT/s 2400
UCS-CPU-E52695E E5-2695 v4 2.1 120 45 18 9.6 GT/s 2400
UCS-CPU-E52690E E5-2690 v4 2.6 135 35 14 9.6 GT/s 2400
UCS-CPU-E52683E E5-2683 v4 2.1 120 40 16 9.6 GT/s 2400
UCS-CPU-E52680E E5-2680 v4 2.4 120 35 14 9.6 GT/s 2400
UCS-CPU-E52667E E5-2667 v4 3.2 135 25 8 9.6 GT/s 2400
UCS-CPU-E52660E E5-2660 v4 2 105 35 14 9.6 GT/s 2400
UCS-CPU-E52650E E5-2650 v4 2.2 105 30 12 9.6 GT/s 2400
UCS-CPU-E52650LE E5-2650L v4 1.7 65 35 14 9.6 GT/s 2400
UCS-CPU-E52643E E5-2643 v4 3.4 135 20 6 9.6 GT/s 2400
UCS-CPU-E52640E E5-2640 v4 2.4 90 25 10 8.0 GT/s 2133
UCS-CPU-E52637E E5-2637 v4 3.5 135 15 4 9.6 GT/s 2400
UCS-CPU-E52630E E5-2630 v4 2.2 85 25 10 8.0 GT/s 2133
UCS-CPU-E52630LE E5-2630L v4 1.8 55 25 10 8.0 GT/s 2133
UCS-CPU-E52623E E5-2623 v4 2.6 85 10 4 8.0 GT/s 2133
UCS-CPU-E52620E E5-2620 v4 2.1 85 20 8 8.0 GT/s 2133
UCS-CPU-E52609E E5-2609 v4 1.7 85 20 8 6.4 GT/s 1866
UCS-CPU-E52658E E5-2658 v4 2.3 105 35 14 9.6 GT/s 2400
UCS-CPU-E52680D E5-2680 v3 2.5 120 30 12 8.0 GT/s 2133
UCS-CPU-E52640D E5-2640 v3 2.6 90 20 8 6.4 GT/s 1866
UCS-CPU-E52620D E5-2620 v3 2.4 85 15 6 6.4 GT/s 1866
UCS-CPU-E52609D E5-2609 v3 1.9 85 15 6 - 1600
UCS-CPU-E52658D E5-2658 v3 2.2 105 30 12 8.0 GT/s 2133
Footnote:
[1]If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock
[1]You can select either one processor or two identical processors.
[2]For optimal performance, select DIMMs with the highest clock speed for a given processor

Available DIMMs and Memory Mirroring

Product ID (PID) PID Description Voltage Ranks /DIMM
2400-MHz DIMM Options
UCS-ML-1X644RV-A 64GB DDR4-2400-MHz LRDIMM/PC4-19200/quad rank/x4 1.2 V 4
UCS-MR-1X322RV-A 32GB DDR4-2400-MHz RDIMM/PC4-19200/dual rank/x4 1.2 V 2
UCS-MR-1X161RV-A 16GB DDR4-2400-MHz RDIMM/PC4-19200/single rank/x4 1.2 V 1
UCS-MR-1X081RV-A 8 GB DDR4-2400-MHz RDIMM/PC4-19200/single rank/x4 1.2 V 1
Memory Mirroring Option
N01-MMIRROR Memory mirroring option - -
Footnote:
[1-CPU]Without memory mirroring: Select from 1 to 12 DIMMs.
[2-CPU]Without memory mirroring: Select from 1 to 12 DIMMs.
[1]System performance is optimized when the DIMM type and quantity are equal for both CPUs, and when all channels are filled equally across the CPUs in the server.
[2]System speed is dependent on how many DIMMs are populated per channel and the CPU DIMM speed support.
[3]When you mix 2400 MHz RDIMMs of different sizes (for example, 4x32GB + 4x16GB), the memory speed clocks one step down to 2133 MHz.
[4]Do not mix RDIMMs with LRDIMMs
[5]Do not mix 64GB DDR4-2133-MHz TSV-RDIMMs with any other DIMMs
[6]Single-rank DIMMs can be mixed with dual-rank DIMMs in the same channel
[7]Do not mix quad-rank DIMMs with single- or dual-rank DIMMs in the same channel
[8]DIMMs for CPU 1 and CPU 2 (when populated) must always be configured identically.
[9]When using mirroring, DIMMs must be installed in identical pairs across paired DDR4 buses. That is, mirrored pairs in channels A and B must be identical and pairs in channels C and D must be identical. However, the DIMMs used in channels A and B can be different from those in channels C and D.
[10]Memory mirroring reduces the amount of available memory by 50% (quantity of DIMMs must be even for mirroring).
[11]Non-ECC DIMMs are not supported.
[12]Cisco memory from previous generation servers (DDR3) is not compatible with this server

Available RAID Controllers

Product ID (PID) PID Description
UCSC-MRAID12GCisco 12G SAS Modular RAID Controller
  • Supports up to 24 internal SAS HDDs and SAS/SATA SSDs (limited to 4 drives in this server)
  • Supports JBOD, RAID 0, 1, 10 (with no FBWC option chosen) and has the ability to also support RAID 5, 6 if a Flash-Backed Write cache upgrade is chosen (shown below in this table)
  • SED drives are compatible with only with the combination of a UCSC-MRAID12G RAID controller along with one of the flash-back write cache modules (UCSC-MRAID12G-1GB, UCSC-MRAID12G-2GB, or UCSC-MRAID12G-4GB).
  • For all self-encrypting drives (SED), standalone Management (CIMC) is supported for configuring and managing local keys (UCSM is not supported). For now, SED drives are managed with local key management only. In the future, third-party key management will be supported.
UCSC-SAS12GHBACisco 12 Gbps Modular SAS HBA
  • Supports up to 24 internal SAS HDDs and SAS/SATA SSDs (limited to 4 drives in this server)
  • Supports JBOD mode only (no RAID functionality. Ideal for SDS (Software Defined Storage) applications. It is also ideal for environments demanding the highest IOPs (for external SSD attach), where a RAID controller can be an I/O bottleneck.
UCSC-PSAS12GHBA [1]Same functionality as UCSC-SAS12GHBA, but vendor is Microsemi
Flash-Backed Write Cache (FBWC) Upgrade Options for Cisco 12G SAS Modular RAID controller
UCSC-MRAID12G-512512 MB FBWC, which includes a 512 MB memory plus a SuperCap for data cache power backup for the Cisco 12G SAS Modular RAID controller. Supports JBOD, RAID 0, 1, 5, and 50.
UCSC-MRAID12G-1GB1 GB FBWC, which includes a 1 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60.
UCSC-MRAID12G-2GB2 GB FBWC, which includes a 2 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60.
UCSC-MRAID12G-4GB4 GB FBWC, which includes a 4 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60.
SAS HBA for External JBOD Attach Two SFF8644 mini-SAS HD connectors on this card are accessible at the rear of the chassis.
UCSC-SAS9300-8ECisco 9300-8e 12G SAS HBA for external JBOD attach
Supports external JBOD using X8 wide SAS ports.
SuperCap Option
UCSC-MRAID-SC=Spare SuperCap for Cisco 12G SAS Modular RAID, including all cables. This is a spare SuperCap. It is the exact same SuperCap that ships with the FBWC options listed earlier in this table and can be used as a replacement or upgrade part.
RAID Configuration Options (not available for Cisco 12 Gbps Modular SAS HBA or embedded software RAID)
R2XX-SRAID0Enable Single Disk Raid 0 Setting
R2XX-RAID0Factory preconfigured RAID striping option Enable RAID 0 Setting. Requires a minimum of one hard drive.
R2XX-RAID1Factory preconfigured RAID mirroring option Enable RAID 1 Setting. Requires exactly two drives with the same size, speed, capacity.
R2XX-RAID5Factory preconfigured RAID option Enable RAID 5 Setting. Requires a minimum of three drives of the same size, speed, capacity.
R2XX-RAID6Factory preconfigured RAID option Enable RAID 6 Setting. Requires a minimum of four drives of the same size, speed, capacity.
Footnote:
[1]Use the same capacity for each drive in each RAID volume
[2]Embedded RAID = 8
[3]Cisco 12G SAS Modular RAID controller = 64
[4]The Cisco 12G SAS Modular RAID controller upgrade option supports up to 4 internal drives with up to RAID 0, 1, 10, 5, 6, 50, 60 support (with FBWC option chosen).
[5]The Cisco 12 Gbps Modular SAS HBA upgrade option supports up to 4 internal drives with JBOD support.
[6]The Cisco 9300-8e 12G SAS HBA supports up to 8 external SAS ports with JBOD support.

Available Drives

Product ID (PID) PID Description Drive Type Capacity
HDDs
UCS-HD8T7KEM 8 TB 12G SAS 7.2K RPM LFF HDD (512e) SAS 8 TB
UCS-HD4T7KL12G 4 TB 12G SAS 7.2K RPM LFF HDD SAS 4 TB
UCS-HD2T7KL12G 2 TB 12G SAS 7.2K RPM LFF HDD SAS 2 TB
UCS-HD10T7KEM 10 TB 12G SAS 7.2K RPM LFF HDD (512e) SAS 10 TB
UCS-HD6T7KEM 6 TB 12G SAS 7.2K RPM LFF HDD (512e) SAS 6 TB
UCS-HD1T7KL12G 1 TB 12G SAS 7.2K RPM LFF HDD SAS 1 TB
UCS-HD10T7KL4K [1] 10 TB 12G SAS 7.2K RPM LFF HDD (4K) SAS 10 TB
UCS-HD8T7KL4KHM 8 TB 12G SAS 7.2K RPM LFF HDD (4K) SAS 8 TB
UCS-HD6T7KL4K [1] 6 TB 12G SAS 7.2K RPM LFF HDD (4K) SAS 6 TB
UCS-HD12T7KL6GHA 12 TB 6G SATA 7.2K RPM LFF HDD (512e) SAS 12 TB
UCS-HD2T7KL6GA 2 TB 6G SATA 7.2K RPM LFF HDD SATA 2 TB
UCS-HD6T12GK9 6 TB 12G SAS 7.2K RPM LFF HDD (512e) SAS 6 TB
UCS-HD4T7KS3-E 4TB SAS 7.2K RPM LFF HDD SAS 4 TB
UCS-HD8T7KL6GA 8TB 6G SATA 7.2K RPM LFF HDD SATA 8 TB
UCS-HD10T7KL6GA 10TB 6G SATA 7.2K RPM LFF HDD SATA 10 TB
UCS-HD12T7KL4KHM 12 TB 12G SAS 7.2K RPM LFF HDD (4K) SAS 12 TB
UCS-HD12TB10KHY-E 1.2 TB 3.5 inch 12G SAS 10K RPM HDD SAS 1.2 TB
UCS-HD600G15KHY-E 600 GB 3.5 inch Hybrid 6G SAS 15K RPM HDD SAS 600 GB
UCS-HD300G15KHY-E 300 GB 3.5 inch Hybrid 6G SAS 15K RPM HDD SAS 300 GB
SSDs
UCS-SD16TG1KHY-EP 1.6TB 3.5 inch Enterprise performance 6G SATA SSD (10X DWPD) SATA 1.6 TB
UCS-SD400G1KHY-EP 400GB 3.5 inch Enterprise performance 6G SATA SSD (10X DWPD) SATA 400 GB
UCS-HY480GIS3-EP 480GB 3.5in Enterprise performance 6GSATA SSD(3X endurance) (Intel S4600) SATA 480 GB
UCS-HY19TIS3-EP 1.9TB 3.5in Enterprise performance 6GSATA SSD(3X endurance) (Intel S4600) SATA 1.9 TB
UCS-HY16TSAS3-EP 1.6TB 3.5in Enterprise performance 12G SAS SSD (3X DWPD) SAS 1.6 TB
UCS-HY800GSAS3-EP 800GB 3.5in Enterprise performance 12G SAS SSD (3X DWPD) SAS 800 GB
UCS-HY400GSAS3-EP 400GB 3.5in Enterprise performance 12G SAS SSD (3X DWPD) SAS 400 GB
Sled-Mounted Self-Encrypting HDDs and SSDs
HDDs
UCS-HD6T12GAK9 [2] 6 TB 7.2K RPM LFF HDD (4K sector format, SED) SAS 6 TB
UCS-HD4T12GK9 4 TB 7.2K RPM HDD (SED) SAS 4 TB
UCS-HD600G15CK9 600 GB 12G SAS 15K RPM LFF HDD (SED) SAS 600 GB
SSDs
UCS-SD800GBCK9 800GB Enterprise performance SAS LFF SSD (10X DWPD, SED) SAS 800 GB
UCS-SD400GBCK9 400GB Enterprise performance SAS LFF SSD (10X DWPD, SED) SAS 400 GB
Footnote:
[Approved Configurations]-
[1]Cisco 12G SAS Modular RAID Controller
If you selected a Cisco 12G SAS Modular RAID controller you have the following options:
  • — Cisco 12G SAS Modular RAID controller with no FBWC option (supports JBOD, RAID 0, 1, 10)
  • — Cisco 12G SAS Modular RAID controller with FBWC option (supports JBOD and up to RAID 0, 1, 10, 5, 6, 50, and 60)
  • — For either option, select up to eight SAS HDDs, eight SAS SSDs, or eight SATA SSDs listed in Table 10. The Cisco 12G SAS Modular RAID controller does not support SATA HDDs.
[2]Cisco 12 Gbps Modular SAS HBA
If you selected a Cisco 12 Gbps Modular SAS HBA you have the following option: Select up to 4 HDDs
[Caveats]-
[1]You can choose only SAS HDDs when using the Cisco 12G SAS Modular RAID Controller.
[2]SED drives can be mixed with the non-SED drives
[3]SED drives are compatible with only with the combination of a UCSC-MRAID12G RAID controller along with one of the flash-back write cache modules:
UCSC-MRAID12G-1GB,
— UCSC-MRAID12G-2GB,
— UCSC-MRAID12G-4GB

Available PCIe Option Cards

Product ID (PID) PID Description Card Height
Modular LAN on Motherboard (mLOM)
UCSC-MLOM-C10T-02 Cisco UCS VIC1227T VIC MLOM - Dual Port 10GBaseT N/A
UCSC-MLOM-CSC-02 Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+ N/A
UCSC-MLOM-IRJ45 Intel i350 quad-port MLOM NIC N/A
UCSC-MLOM-C40Q-03 Cisco VIC 1387 Dual Port 40Gb QSFP CNA MLOM N/A
Virtual Interface Cards (VICs)
UCSC-PCIE-CSC-02 Cisco VIC 1225 Dual Port 10Gb SFP+ CNA Half
UCSC-PCIE-C10T-02 Cisco VIC 1225T Dual Port 10GBaseT CNA Half
UCSC-PCIE-C40Q-03 Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA Half
Network Interface Cards (NICs)
1 Gb NICs
N2XX-ABPCI03-M3 Broadcom 5709 Quad Port 1Gb w/TOE iSCSI for M3 Servers Half
N2XX-ABPCI01-M3 Broadcom 5709 Dual-Port Ethernet PCIe Adapter M3 & later Half
UCSC-PCIE-IRJ45 Intel i350 Quad Port 1Gb Adapter Half
10 Gb NICs
N2XX-AIPCI01 [2] Intel X520 Dual Port 10Gb SFP+ Adapter Half
UCSC-PCIE-ITG Intel X540 Dual Port 10GBase-T Adapter Half
UCSC-PCIE-QNICBT QLogic QLE8442 dual-port 10Gbase-T NIC Half
UCSC-PCIE-QNICSFP QLogic QLE8442 dual-port 10G SFP+ NIC Half
UCSC-PCIE-ID10GC Intel X550-T2 dual-port 10GBase-T NIC Half
UCSC-PCIE-ID10GF Intel X710-DA2 dual-port 10G SFP+ NIC Half
UCSC-PCIE-IQ10GF Intel X710 quad-port 10G SFP+ NIC Half
UCSC-PCIE-ID40GF Intel XL710 dual-port 40G QSFP+ NIC Half
10 Gb Converged Network Adapters (CNAs)
UCSC-PCIE-E14102B Emulex OCe14102B-UX dual-port 10G SFP+ with iSCSI, FCoE CNA Half
UCSC-PCIE-E14102 Emulex OCe14102-UX dual-port 10 GbE FCoE CNA Half
UCSC-PCIE-Q8362 Qlogic QLE8362 dual-port 10 GbE FCoE CNA Half
Host Bus Adapters (HBAs)
UCSC-PCIE-BS32GF Broadcom LPe32000 Single-Port 32G FC HBA Half
UCSC-PCIE-BD32GF Broadcom LPe32002 Dual-Port 32G FC HBA Half
UCSC-PCIE-QD32GF Qlogic QLE2742 dual-port 32G FC HBA N2XX-AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Half
N2XX-AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Half
UCSC-PCIE-Q2672 Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics N2XX-AEPCI05 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Half
N2XX-AEPCI05 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Half
UCSC-PCIE-E16002 Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics Half
UCS Storage Accelerators [3]
UCSC-F-S13002 UCS Rack PCIe Storage 1300 GB SanDisk SX350 Medium Endurance Half
UCSC-F-S16002 UCS Rack PCIe Storage 1600 GB SanDisk SX350 Medium Endurance Half
UCSC-F-S32002 UCS Rack PCIe Storage 3200 GB SanDisk SX350 Medium Endurance Half
UCSC-F-S64002 UCS Rack PCIe Storage 6400 GB SanDisk SX350 Medium Endurance Full
UCS NVMe/PCie Add in Cards
UCSC-F-H38001 3.8 TB NVMe/PCIe storage (HGST SN150) Read Intensive Half
UCSC-NVME-H64003 Cisco HHHL AIC 6.4T HGST SN260 NVMe Extreme Perf High Endurance HHHL*
UCSC-NVME-H76801 Cisco HHHL 7.7T HGST SN260 NVMe Extreme Perf Value Endurance HHHL*
UCSC-NVME-H32003 Cisco HHHL AIC 3.2T HGST SN260 NVMe Extreme Perf High Endurance HHHL*
*HHHL= Half Height Half Length
Footnote:
[1]The mLOM cards do not plug into any of the riser 1 or riser 2 card slots
[2]The Intel X520 supports the following Cisco PIDs: UCS-SFP-1WLR and UCS-SFP-1WSR SFPs. Refer to the Intel X520 product brief for a full list of supported optics and cables
[3]A maximum of two storage accelerator cards are supported if they are half height
[Approved Configurations]-
[1-CPU Systems]You can select up to one PCie option card (slot 1 for 1-CPU systems)
[2-CPU Systems]You can select up to two PCie option cards (slots 1 and 2 for 2-CPU systems)
[Caveats]-
[1]A maximum of two storage accelerator cards are supported if they are half height
[2]For 1-CPU systems:
Only the full-height PCIe slot on riser 1 (slot 1) is supported
— Only a single plug-in PCIe VIC card is supported and must be installed in slot 1 (the full-height slot). However, in addition to the one PCIe VIC card, you can also choose to install an mLOM VIC card.
— If any of the Storage Accelerator cards are installed, they can be installed only in slot 1.
[3]For 2-CPU systems:
Both PCIe slots(slots 1 and 2) are supported
— Two plug-in PCIe VIC cards can be installed in 2-CPU systems, using slots 1 and 2. In addition, you can order an mLOM VIC card, which is installed in the mLOM slot inside the chassis and thus have three VIC cards in operation at the same time.
—If any of the Storage Accelerator cards are installed, they can be installed only in slot 1

Available Power Supply

Product ID (PID) PID Description
UCSC-PSU1-770W770W AC power supply for C-Series Servers
UCSC-PSU1-1050W1050W AC power supply for C-Series servers
Footnote:
[1]The C220 M4 LFF server accommodates two power supplies. A lightly loaded server can operate from one 770 W AC power supply or one 1050 W DC power supply. A fully loaded server might need to be powered with two 770 W power supplies
[2]In a two power supply server, both power supplies must be identical.

Available Power Cords

Product ID (PID) PID Description
R2XX-DMYMPWRCORDNo power cord (dummy PID to allow for a no power cord option)
CAB-N5K6A-NAPower Cord, 200/240V 6A, North America
CAB-AC-L620-C13AC Power Cord, NEMA L6-20 - C13, 2M/6.5ft
CAB-C13-CBNCABASY,WIRE,JUMPER CORD, 27" L, C13/C14, 10A/250V
CAB-C13-C14-2MCABASY,WIRE,JUMPER CORD, PWR, 2 Meter, C13/C14,10A/250V
CAB-C13-C14-ACCORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M
CAB-250V-10A-ARPower Cord, 250V, 10A, Argentina 186571 2500 mm Cordset rating: 10 A, 250/500 V MAX Length: 8.2 ft Plug: EL 219 (IRAM 2073) Connector: EL 701 (IEC60320/C13)
CAB-9K10A-AUPower Cord, 250VAC 10A 3112 Plug, Australia Plug: Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm 186580 Connector: EL 701C EL 210 (EN 60320/C15) (BS 1363A) 13 AMP fuse
SFS-250V-10A-CNPower Cord, SFS, 250V, 10A, China
CAB-250V-10A-CNAC Power Cord - 250V, 10A - PRC
CAB-9K10A-EUPower Cord, 250VAC 10A CEE 7/7 Plug, EU Connector: VSCC15 Cordset rating: 10A/16 A, 250 V Length: 8 ft 2 in. (2.5 m) Plug: M2511 186576
SFS-250V-10A-IDPower Cord, SFS, 250V, 10A, India
SFS-250V-10A-ISPower Cord, SFS, 250V, 10A, Israel
CAB-9K10A-ITPower Cord, 250VAC 10A CEI 23-16/VII Plug, Italy Plug: I/3G (CEI 23-16) Connector C15M (EN60320/C15 ) Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) 186575
CAB-9K10A-SWPower Cord, 250VAC 10A MP232 Plug, Switzerland Plug: MP232-R Cordset rating: 10 A, 250 V Length: 8 ft. 2 in (2.5 m) 186578 Connector: IEC 60320 C15
CAB-9K10A-UKPower Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK
CAB-9K12A-NAPower Cord, 125VAC 13A NEMA 5-15 Plug, North America
CAB-250V-10A-BRPower Cord - 250V, 10A - Brazil
CAB-48DC-40A-8AWGPower Cord for -48VDC PSU, 3.5M, 3 Wire, 8AWG, 4
CAB-JPN-3PINPower Cord 3PIN, Japan
CAB-C19-C20-3M-JPPower Cord C19-C20, 3M/10ft Japan PSE mark

Available NIC Mode (Optional)

Product ID (PID) PID Description
UCSC-DLOM-01Dedicated Mode BIOS setting for C-Series Servers
UCSC-CCARD-01Cisco Card Mode BIOS setting for C-Series Servers
Footnote:
[1]By default, the C220 M4 server NIC mode is configured to be Shared LOM Extended. This NIC mode allows any LOM port or adapter card port to be used to access the Cisco Integrated Management Controller (CIMC). The Cisco VIC card must be installed in a slot with NCSI support.
[2]To change the default NIC mode to Dedicated, select the UCSC-DLOM-01 PID shown in Table Above. In Dedicated NIC mode, the CIMC can be accessed only through the dedicated management port.
[3]To change the default NIC mode to Cisco Card Mode, select the UCSC-CCARD-01 PID shown in Table Above. In this mode, you can assign an IP address to the CIMC using DHCP and from there you can fully automate your deployment.

Cisco SD Card Module (Optional)

Product ID (PID) PID Description
UCS-SD-128G128 GB SD Card for UCS Servers
UCS-SD-64G-S64 GB SD Card for UCS Servers
UCS-SD-32G-S32 GB SD Card for UCS Servers
Footnote:
[1]Order one or two matching SD cards. See Figure 5 on page 73 for the location of the mini storage module connector, which accommodates an SD module. Each SD module accommodates two SD cards.
[Caveats]-
[1]Install either one or two SD cards
[2]Do not mix SD card sizes
[3]You cannot mix SD cards with an internal M.2 SATA SSD

Spare Parts List

Product ID (PID) PID Description
UCSC-HS-C220M4=Heat sink for UCS C220 M4 rack servers
UCS-CPU-GREASE3=M4 Server CPU thermal grease syringe - needed for heatsink seal
UCS-CPU-CVR-EP-M4=CPU load plate dust cover (for unpopulated CPU sockets)
UCSX-HSCK=UCS Processor Heat Sink Cleaning Kit For Replacement of CPU
UCSC-PCI-2A-220M4=C220 M4 PCIe Riser 1&2 Assy
UCSC-PCI-2C-220M4=C220 M4 PCIe Riser 3 (HBA)
UCSC-PCIF-01H=PCIe Low Profile blanking panel for UCS C-Series Server
UCSC-PCIF-01F=PCIe Full Height blanking panel for UCS C-Series Server
UCSC-BBLKD-L3.5-inch HDD blanking panel [1]
UCSC-MLOM-BLK=MLOM blanking panel
UCSC-RAILF-M4=Tool-Less Friction Rail Kit for C220 M4 rack servers
UCSC-CMAF-M4=Reversible CMA for C220 M4 friction & ball bearing rail kits
UCSC-RAILB-M4=Tool-Less Ball Bearing Rail Kit for C220 M4 and C220 M4 rack servers
UCSC-FAN-C220M4=C220 M4 Fan Module (one)
UCSC-BAFF-C220M4=C220 M4 Air Baffle, Plastic Kit
N20-BKVM=KVM cable for Server console port
UCSC-PSU-BLKP1U=Power Supply Blanking Panel for C220 M4 servers
UCS-220CBLSR4=C220 M4 SATA/SW RAID cable (1) for 4 HDD backplane chassis2
UCS-220CBLMR4=C220 M4 RAID controller cable (1) for 4HDD bckpln chassis2
UCSC-EARS-C220M4=C200 M4 rack ears kit (two ears)
Footnote:
[1]A drive blanking panel must be installed if you remove a disk drive from a UCS server. These panels are required to maintain system temperatures at safe operating levels, and to keep dust away from system components.
[2]Required if ordering the RAID controller as a spare or to replace damaged cables

PCIe Card Compatibility

PCIe Cards Twinax Cables Cisco SFP Modules
SFP-10G-SR SFP-10G-LR DS-SFP-FC8G-SW
Converged Network Adapters (CNAs)
UCSC-PCIE-BSFP (Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI) Yes Yes No
UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA) Yes Yes Yes No
UCSC-PCIE-C10T-02 (Cisco VIC 1225T Dual Port 10GBaseT CNA) No No No No
UCSC-MLOM-CSC-02 (Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+) Yes Yes Yes No
UCSC-MLOM-C10T-02 (Cisco UCS VIC1227T VIC MLOM - Dual Port 10GBaseT) No No No No
UCSC-PCIE-C40Q-02 (Cisco VIC 1285 Dual Port 40Gb QSFP CNA) Yes No [1] No
UCSC-PCIE-C40Q-03 (Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA) Yes No [1] No
UCSC-PCIE-ESFP (Emulex OCe11102-FX dual-port 10 GbE FCoE CNA (Gen 3 CNA)) Yes Yes No
UCSC-PCIE-QSFP (QLogic QLE8242-CU dual-port 10 GbE FCoE CNA) Yes Use Qlogic SFP
UCSC-PCIE-B3SFP (Broadcom 57810 10Gb A-FEX SFP+ Yes Yes No
UCSC-PCIE-Q8362 (Qlogic QLE8362 dual-port 10 GbE FCoE CNA) Yes Use Qlogic SFP
UCSC-PCIE-E14102 (Emulex OCe14102-UX dual-port 10 GbE FCoE CNA) Yes Yes No
Network Interface Cards (NICs)
N2XX-ABPCI01-M3 (Broadcom 5709 Dual-Port Ethernet PCIe Adapter for M3 Servers) Use RJ45 Ethernet cable
N2XX-ABPCI03-M3 (Broadcom 5709 Quad Port 10/100/1Gb NIC w/TOE iSCSI for M3 Servers Use RJ45 Ethernet cable
N2XX-AIPCI01 (Intel X520 Dual Port 10Gb SFP+ Adapter) Yes Use Intel SFP UCS-SFP-1WLR or UCS-SFP-1WSR
UCSC-PCIE-ITG (Intel X540 Dual Port 10GBase-T Adapter) Use RJ45 Ethernet cable
UCSC-PCIE-IRJ45 (Intel i350 Quad Port 1Gb Adapter Use RJ45 Ethernet cable
UCSC-PCIE-BTG(Broadcom 57712 Dual Port 10GBASE-T w/TOE iSCSI) Yes No No
Host Bus Adapters (HBAs)
N2XX-AEPCI03 (Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA No Preinstalled - do not change SFP
N2XX-AEPCI05 (Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA) No Preinstalled - do not change SFP
N2XX-AQPCI03 (QLogic QLE2462 Dual Port 4Gb Fibre Channel HBA) No Preinstalled - do not change SFP
N2XX-AQPCI05 (QLogic QLE2562 Dual Port 8Gb Fibre Channel HBA) No Preinstalled - do not change SFP
UCSC-PCIE-Q2672 (Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics) No Preinstalled - do not change SFP
UCSC-PCIE-E16002 (Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics) No Preinstalled - do not change SFP
Footnotes:
[1] This card supports a 4x10 Gbps QSFP to SFP breakout fiber cable.

Shipping Information

Express Computer Systems can ship to virtually any address in the world and provides you with the best shipping rates possible. Cost of shipping varies depending on what service you require, your destination and size of the shipment. Shipping costs will be calculated separately from your order and billed to you post purchase. In the notes section of your order please provide us with your preferred shipping method and we will get back to you.

Custom configured orders ship within 2 business days after all required products are in stock.

Please allow 3 business days for products that are not in stock to arrive to our facility in Irvine, California.

Domestic Shipments
  • Standard Ground
    • Shipping time: 2-7 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-10 business days
    • Excludes weekends, holidays or weather delays.
  • 3 Business Days
    • Shipping time: 3 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 3-6 business days
    • Excludes weekends, holidays or weather delays.
  • 2 Business Days
    • Shipping time: 2 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-5 business days
    • Excludes weekends, holidays or weather delays.
  • Overnight / Next Business Day
    • Shipping time: 1 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 1-4 business days
    • Excludes weekends, holidays or weather delays.
International Shipments
  • International Economy
    • Shipping time: 4-6 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 5-9 business days
    • Excludes weekends, holidays or weather delays.
  • International Priority
    • Shipping time: 1-3 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-6 business days
    • Excludes weekends, holidays or weather delays.

For more information on shipping view our Shipping Information page or send us a message

ECS Warranty Information

Express Computer Systems (ECS) provides a 1 year parts warranty against defects in material or workmanship that will affect the products functionality. All refurbished items are tested prior to shipping to guarantee up-time upon arrival. If you are having issues with an item we provided please Contact Us and we will do our best to assist you.

What does our ECS warranty cover?
We offer 1 year warranty as standard and additional years can be added to fit your needs. Please reach out to a sales associate via the Contact Us page or live chat for more information on extended coverage options. During the coverage period if your product fails we will offer a Next Business Day replacement. If we are unable to replace the product we will refund its original selling price. Shipping costs and tax are not refundable. Express Computer Systems retains the right to decide whether the goods will be replaced or refunded.

What is not covered by our warranty?
Our warranty does not cover any problem caused by the following conditions:

  1. accidents; misuse; carelessness; electrostatic discharge; shock; temperature or humidity beyond the specifications of the product; improper installation; operation; modification;
  2. any improper use that contravenes the instructions in the user manual;
  3. problems caused by other equipment. Our warranty is void if the product is returned with damaged, removed, counterfeit labels, or any modifications (including any component or external cover removal). Our warranties do not cover data loss or damages to any other equipment. In addition, our warranties do not cover incidental damages, consequential damages, or costs related to data recovery, removal, and installation.

Important notes:

  • Please ask for additional warranty/coverage that you may require in addition to the standard 1 ECS warranty prior to final purchase. Requesting additional warranty after your purchase can be denied.
  • FREE technical support is provided on purchased items via phone, email, or live chat.

About Express Computer Systems

Express Computer Systems is committed to transforming our customers’ IT infrastructure with high quality products at affordable costs. Our sales reps and customer support engineers understand our customers rely heavily on advanced technology to run their business but need to do so without breaking the bank.

We specialize in building custom server configurations, custom storage solutions, networking solutions, and components from top manufacturers including HPE, Dell, Cisco, NetApp, Dell EMC, HPE Nimble and many others.

Subscribe