Base Standard Capabilities
Capability / Feature | Description | ||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Chassis | One rack unit (1RU) chassis | ||||||||||||||||||||||||||||||||||
CPU | One or two Intel® Xeon E5-2600 v3 or v4 series processor family CPUs | ||||||||||||||||||||||||||||||||||
Chipset | Intel® C610 series chipset | ||||||||||||||||||||||||||||||||||
Memory | 24 slots for DDR4 registered DIMMs (RDIMMs) or load-reduced DIMMs (LRDIMMs) | ||||||||||||||||||||||||||||||||||
Multi-bit Error Protection | This server supports multi-bit error protection. | ||||||||||||||||||||||||||||||||||
Embedded NIC | Two embedded (on the motherboard) Intel i350 GbE ports, supporting the following:
| ||||||||||||||||||||||||||||||||||
Expansion slots |
| ||||||||||||||||||||||||||||||||||
Internal storage devices | Drives are installed into front-panel drive bays that provide hot-pluggable access. • Large Form Factor (LFF) drives. Up to four 3.5-inch SAS hot-swappable hard disk drives (HDDs)1.
| ||||||||||||||||||||||||||||||||||
Cisco Flexible Flash drives | The server supports up to two internal 32 GB or two internal 64 GB Cisco Flexible Flash drives (SD cards). The second SD card is blank and can be used to mirror the first SD card. It can be used to protect the Hypervisor Partition with RAID1. | ||||||||||||||||||||||||||||||||||
Video | The Cisco Integrated Management Controller (CIMC) provides video using the Matrox G200e video/graphics controller:
| ||||||||||||||||||||||||||||||||||
Interfaces |
| ||||||||||||||||||||||||||||||||||
Storage controller | Cisco 12G SAS Modular RAID controller card with internal SAS connectivity.
| ||||||||||||||||||||||||||||||||||
Modular LAN on Motherboard (mLOM) slot | The mLOM slot can flexibly accommodate the following cards:
| ||||||||||||||||||||||||||||||||||
WoL | The 1-Gb Base-T Ethernet LAN ports support the wake-on-LAN (WoL) standard. | ||||||||||||||||||||||||||||||||||
Front Panel | A front panel controller provides status indications and control buttons | ||||||||||||||||||||||||||||||||||
Power subsystem | Up to two 770 W (AC) hot swappable power supplies or two 1050 W (DC) power supplies. One is mandatory; one more can be added for 1 + 1 redundancy. | ||||||||||||||||||||||||||||||||||
ACPI | This server supports the advanced configuration and power interface (ACPI) 4.0 standard. | ||||||||||||||||||||||||||||||||||
Fans | Chassis: Six hot-swappable fans for front-to-rear cooling | ||||||||||||||||||||||||||||||||||
Integrated management processor | Baseboard Management Controller (BMC) running Cisco Integrated Management Controller (CIMC) firmware. Depending on your CIMC settings, the CIMC can be accessed through the 1-GbE dedicated management port, the 1-GbE LOM ports, or a Cisco virtual interface card (VIC). | ||||||||||||||||||||||||||||||||||
Notes | |||||||||||||||||||||||||||||||||||
1. The drives are available as both self-encrypted drives (SED) and non self-encrypted drives. |
Available CPU's
Product ID (PID) | Intel Number | Clock Freq (GHz) | Power (W) | Cache Size (MB) | Cores | QPI | Highest DDR4 DIMM Clock Support (MHz) [1] | |||
---|---|---|---|---|---|---|---|---|---|---|
UCS-CPU-E52699AE | E5-2699A v4 | 2.4 | 145 | 55 | 22 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52699E | E5-2699 v4 | 2.2 | 145 | 55 | 22 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52698E | E5-2698 v4 | 2.2 | 135 | 50 | 20 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52697AE | E5-2697A v4 | 2.6 | 145 | 40 | 16 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52697E | E5-2697 v4 | 2.3 | 145 | 45 | 18 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52695E | E5-2695 v4 | 2.1 | 120 | 45 | 18 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52690E | E5-2690 v4 | 2.6 | 135 | 35 | 14 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52683E | E5-2683 v4 | 2.1 | 120 | 40 | 16 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52680E | E5-2680 v4 | 2.4 | 120 | 35 | 14 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52667E | E5-2667 v4 | 3.2 | 135 | 25 | 8 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52660E | E5-2660 v4 | 2 | 105 | 35 | 14 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52650E | E5-2650 v4 | 2.2 | 105 | 30 | 12 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52650LE | E5-2650L v4 | 1.7 | 65 | 35 | 14 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52643E | E5-2643 v4 | 3.4 | 135 | 20 | 6 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52640E | E5-2640 v4 | 2.4 | 90 | 25 | 10 | 8.0 GT/s | 2133 | |||
UCS-CPU-E52637E | E5-2637 v4 | 3.5 | 135 | 15 | 4 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52630E | E5-2630 v4 | 2.2 | 85 | 25 | 10 | 8.0 GT/s | 2133 | |||
UCS-CPU-E52630LE | E5-2630L v4 | 1.8 | 55 | 25 | 10 | 8.0 GT/s | 2133 | |||
UCS-CPU-E52623E | E5-2623 v4 | 2.6 | 85 | 10 | 4 | 8.0 GT/s | 2133 | |||
UCS-CPU-E52620E | E5-2620 v4 | 2.1 | 85 | 20 | 8 | 8.0 GT/s | 2133 | |||
UCS-CPU-E52609E | E5-2609 v4 | 1.7 | 85 | 20 | 8 | 6.4 GT/s | 1866 | |||
UCS-CPU-E52658E | E5-2658 v4 | 2.3 | 105 | 35 | 14 | 9.6 GT/s | 2400 | |||
UCS-CPU-E52680D | E5-2680 v3 | 2.5 | 120 | 30 | 12 | 8.0 GT/s | 2133 | |||
UCS-CPU-E52640D | E5-2640 v3 | 2.6 | 90 | 20 | 8 | 6.4 GT/s | 1866 | |||
UCS-CPU-E52620D | E5-2620 v3 | 2.4 | 85 | 15 | 6 | 6.4 GT/s | 1866 | |||
UCS-CPU-E52609D | E5-2609 v3 | 1.9 | 85 | 15 | 6 | - | 1600 | |||
UCS-CPU-E52658D | E5-2658 v3 | 2.2 | 105 | 30 | 12 | 8.0 GT/s | 2133 | |||
Footnote: | ||||||||||
[1] | If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock | |||||||||
[1] | You can select either one processor or two identical processors. | |||||||||
[2] | For optimal performance, select DIMMs with the highest clock speed for a given processor |
Available DIMMs and Memory Mirroring
Product ID (PID) | PID Description | Voltage | Ranks /DIMM | |||||||
---|---|---|---|---|---|---|---|---|---|---|
2400-MHz DIMM Options | ||||||||||
UCS-ML-1X644RV-A | 64GB DDR4-2400-MHz LRDIMM/PC4-19200/quad rank/x4 | 1.2 V | 4 | |||||||
UCS-MR-1X322RV-A | 32GB DDR4-2400-MHz RDIMM/PC4-19200/dual rank/x4 | 1.2 V | 2 | |||||||
UCS-MR-1X161RV-A | 16GB DDR4-2400-MHz RDIMM/PC4-19200/single rank/x4 | 1.2 V | 1 | |||||||
UCS-MR-1X081RV-A | 8 GB DDR4-2400-MHz RDIMM/PC4-19200/single rank/x4 | 1.2 V | 1 | |||||||
Memory Mirroring Option | ||||||||||
N01-MMIRROR | Memory mirroring option | - | - | |||||||
Footnote: | ||||||||||
[1-CPU] | Without memory mirroring: Select from 1 to 12 DIMMs. | |||||||||
[2-CPU] | Without memory mirroring: Select from 1 to 12 DIMMs. | |||||||||
[1] | System performance is optimized when the DIMM type and quantity are equal for both CPUs, and when all channels are filled equally across the CPUs in the server. | |||||||||
[2] | System speed is dependent on how many DIMMs are populated per channel and the CPU DIMM speed support. | |||||||||
[3] | When you mix 2400 MHz RDIMMs of different sizes (for example, 4x32GB + 4x16GB), the memory speed clocks one step down to 2133 MHz. | |||||||||
[4] | Do not mix RDIMMs with LRDIMMs | |||||||||
[5] | Do not mix 64GB DDR4-2133-MHz TSV-RDIMMs with any other DIMMs | |||||||||
[6] | Single-rank DIMMs can be mixed with dual-rank DIMMs in the same channel | |||||||||
[7] | Do not mix quad-rank DIMMs with single- or dual-rank DIMMs in the same channel | |||||||||
[8] | DIMMs for CPU 1 and CPU 2 (when populated) must always be configured identically. | |||||||||
[9] | When using mirroring, DIMMs must be installed in identical pairs across paired DDR4 buses. That is, mirrored pairs in channels A and B must be identical and pairs in channels C and D must be identical. However, the DIMMs used in channels A and B can be different from those in channels C and D. | |||||||||
[10] | Memory mirroring reduces the amount of available memory by 50% (quantity of DIMMs must be even for mirroring). | |||||||||
[11] | Non-ECC DIMMs are not supported. | |||||||||
[12] | Cisco memory from previous generation servers (DDR3) is not compatible with this server |
Available RAID Controllers
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCSC-MRAID12G | Cisco 12G SAS Modular RAID Controller
| |||||||||
UCSC-SAS12GHBA | Cisco 12 Gbps Modular SAS HBA
| |||||||||
UCSC-PSAS12GHBA [1] | Same functionality as UCSC-SAS12GHBA, but vendor is Microsemi | |||||||||
Flash-Backed Write Cache (FBWC) Upgrade Options for Cisco 12G SAS Modular RAID controller | ||||||||||
UCSC-MRAID12G-512 | 512 MB FBWC, which includes a 512 MB memory plus a SuperCap for data cache power backup for the Cisco 12G SAS Modular RAID controller. Supports JBOD, RAID 0, 1, 5, and 50. | |||||||||
UCSC-MRAID12G-1GB | 1 GB FBWC, which includes a 1 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60. | |||||||||
UCSC-MRAID12G-2GB | 2 GB FBWC, which includes a 2 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60. | |||||||||
UCSC-MRAID12G-4GB | 4 GB FBWC, which includes a 4 GB MB memory plus a SuperCap for write cache backup. Supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60. | |||||||||
SAS HBA for External JBOD Attach Two SFF8644 mini-SAS HD connectors on this card are accessible at the rear of the chassis. | ||||||||||
UCSC-SAS9300-8E | Cisco 9300-8e 12G SAS HBA for external JBOD attach Supports external JBOD using X8 wide SAS ports. | |||||||||
SuperCap Option | ||||||||||
UCSC-MRAID-SC= | Spare SuperCap for Cisco 12G SAS Modular RAID, including all cables. This is a spare SuperCap. It is the exact same SuperCap that ships with the FBWC options listed earlier in this table and can be used as a replacement or upgrade part. | |||||||||
RAID Configuration Options (not available for Cisco 12 Gbps Modular SAS HBA or embedded software RAID) | ||||||||||
R2XX-SRAID0 | Enable Single Disk Raid 0 Setting | |||||||||
R2XX-RAID0 | Factory preconfigured RAID striping option Enable RAID 0 Setting. Requires a minimum of one hard drive. | |||||||||
R2XX-RAID1 | Factory preconfigured RAID mirroring option Enable RAID 1 Setting. Requires exactly two drives with the same size, speed, capacity. | |||||||||
R2XX-RAID5 | Factory preconfigured RAID option Enable RAID 5 Setting. Requires a minimum of three drives of the same size, speed, capacity. | |||||||||
R2XX-RAID6 | Factory preconfigured RAID option Enable RAID 6 Setting. Requires a minimum of four drives of the same size, speed, capacity. | |||||||||
Footnote: | ||||||||||
[1] | Use the same capacity for each drive in each RAID volume | |||||||||
[2] | Embedded RAID = 8 | |||||||||
[3] | Cisco 12G SAS Modular RAID controller = 64 | |||||||||
[4] | The Cisco 12G SAS Modular RAID controller upgrade option supports up to 4 internal drives with up to RAID 0, 1, 10, 5, 6, 50, 60 support (with FBWC option chosen). | |||||||||
[5] | The Cisco 12 Gbps Modular SAS HBA upgrade option supports up to 4 internal drives with JBOD support. | |||||||||
[6] | The Cisco 9300-8e 12G SAS HBA supports up to 8 external SAS ports with JBOD support. |
Available Drives
Product ID (PID) | PID Description | Drive Type | Capacity | |||||||
---|---|---|---|---|---|---|---|---|---|---|
HDDs | ||||||||||
UCS-HD8T7KEM | 8 TB 12G SAS 7.2K RPM LFF HDD (512e) | SAS | 8 TB | |||||||
UCS-HD4T7KL12G | 4 TB 12G SAS 7.2K RPM LFF HDD | SAS | 4 TB | |||||||
UCS-HD2T7KL12G | 2 TB 12G SAS 7.2K RPM LFF HDD | SAS | 2 TB | |||||||
UCS-HD10T7KEM | 10 TB 12G SAS 7.2K RPM LFF HDD (512e) | SAS | 10 TB | |||||||
UCS-HD6T7KEM | 6 TB 12G SAS 7.2K RPM LFF HDD (512e) | SAS | 6 TB | |||||||
UCS-HD1T7KL12G | 1 TB 12G SAS 7.2K RPM LFF HDD | SAS | 1 TB | |||||||
UCS-HD10T7KL4K [1] | 10 TB 12G SAS 7.2K RPM LFF HDD (4K) | SAS | 10 TB | |||||||
UCS-HD8T7KL4KHM | 8 TB 12G SAS 7.2K RPM LFF HDD (4K) | SAS | 8 TB | |||||||
UCS-HD6T7KL4K [1] | 6 TB 12G SAS 7.2K RPM LFF HDD (4K) | SAS | 6 TB | |||||||
UCS-HD12T7KL6GHA | 12 TB 6G SATA 7.2K RPM LFF HDD (512e) | SAS | 12 TB | |||||||
UCS-HD2T7KL6GA | 2 TB 6G SATA 7.2K RPM LFF HDD | SATA | 2 TB | |||||||
UCS-HD6T12GK9 | 6 TB 12G SAS 7.2K RPM LFF HDD (512e) | SAS | 6 TB | |||||||
UCS-HD4T7KS3-E | 4TB SAS 7.2K RPM LFF HDD | SAS | 4 TB | |||||||
UCS-HD8T7KL6GA | 8TB 6G SATA 7.2K RPM LFF HDD | SATA | 8 TB | |||||||
UCS-HD10T7KL6GA | 10TB 6G SATA 7.2K RPM LFF HDD | SATA | 10 TB | |||||||
UCS-HD12T7KL4KHM | 12 TB 12G SAS 7.2K RPM LFF HDD (4K) | SAS | 12 TB | |||||||
UCS-HD12TB10KHY-E | 1.2 TB 3.5 inch 12G SAS 10K RPM HDD | SAS | 1.2 TB | |||||||
UCS-HD600G15KHY-E | 600 GB 3.5 inch Hybrid 6G SAS 15K RPM HDD | SAS | 600 GB | |||||||
UCS-HD300G15KHY-E | 300 GB 3.5 inch Hybrid 6G SAS 15K RPM HDD | SAS | 300 GB | |||||||
SSDs | ||||||||||
UCS-SD16TG1KHY-EP | 1.6TB 3.5 inch Enterprise performance 6G SATA SSD (10X DWPD) | SATA | 1.6 TB | |||||||
UCS-SD400G1KHY-EP | 400GB 3.5 inch Enterprise performance 6G SATA SSD (10X DWPD) | SATA | 400 GB | |||||||
UCS-HY480GIS3-EP | 480GB 3.5in Enterprise performance 6GSATA SSD(3X endurance) (Intel S4600) | SATA | 480 GB | |||||||
UCS-HY19TIS3-EP | 1.9TB 3.5in Enterprise performance 6GSATA SSD(3X endurance) (Intel S4600) | SATA | 1.9 TB | |||||||
UCS-HY16TSAS3-EP | 1.6TB 3.5in Enterprise performance 12G SAS SSD (3X DWPD) | SAS | 1.6 TB | |||||||
UCS-HY800GSAS3-EP | 800GB 3.5in Enterprise performance 12G SAS SSD (3X DWPD) | SAS | 800 GB | |||||||
UCS-HY400GSAS3-EP | 400GB 3.5in Enterprise performance 12G SAS SSD (3X DWPD) | SAS | 400 GB | |||||||
Sled-Mounted Self-Encrypting HDDs and SSDs | ||||||||||
HDDs | ||||||||||
UCS-HD6T12GAK9 [2] | 6 TB 7.2K RPM LFF HDD (4K sector format, SED) | SAS | 6 TB | |||||||
UCS-HD4T12GK9 | 4 TB 7.2K RPM HDD (SED) | SAS | 4 TB | |||||||
UCS-HD600G15CK9 | 600 GB 12G SAS 15K RPM LFF HDD (SED) | SAS | 600 GB | |||||||
SSDs | ||||||||||
UCS-SD800GBCK9 | 800GB Enterprise performance SAS LFF SSD (10X DWPD, SED) | SAS | 800 GB | |||||||
UCS-SD400GBCK9 | 400GB Enterprise performance SAS LFF SSD (10X DWPD, SED) | SAS | 400 GB | |||||||
Footnote: | ||||||||||
[Approved Configurations] | - | |||||||||
[1] | Cisco 12G SAS Modular RAID Controller If you selected a Cisco 12G SAS Modular RAID controller you have the following options:
| |||||||||
[2] | Cisco 12 Gbps Modular SAS HBA If you selected a Cisco 12 Gbps Modular SAS HBA you have the following option: Select up to 4 HDDs | |||||||||
[Caveats] | - | |||||||||
[1] | You can choose only SAS HDDs when using the Cisco 12G SAS Modular RAID Controller. | |||||||||
[2] | SED drives can be mixed with the non-SED drives | |||||||||
[3] | SED drives are compatible with only with the combination of a UCSC-MRAID12G RAID controller along with one of the flash-back write cache modules: UCSC-MRAID12G-1GB, — UCSC-MRAID12G-2GB, — UCSC-MRAID12G-4GB |
Available PCIe Option Cards
Product ID (PID) | PID Description | Card Height | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Modular LAN on Motherboard (mLOM) | ||||||||||
UCSC-MLOM-C10T-02 | Cisco UCS VIC1227T VIC MLOM - Dual Port 10GBaseT | N/A | ||||||||
UCSC-MLOM-CSC-02 | Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+ | N/A | ||||||||
UCSC-MLOM-IRJ45 | Intel i350 quad-port MLOM NIC | N/A | ||||||||
UCSC-MLOM-C40Q-03 | Cisco VIC 1387 Dual Port 40Gb QSFP CNA MLOM | N/A | ||||||||
Virtual Interface Cards (VICs) | ||||||||||
UCSC-PCIE-CSC-02 | Cisco VIC 1225 Dual Port 10Gb SFP+ CNA | Half | ||||||||
UCSC-PCIE-C10T-02 | Cisco VIC 1225T Dual Port 10GBaseT CNA | Half | ||||||||
UCSC-PCIE-C40Q-03 | Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA | Half | ||||||||
Network Interface Cards (NICs) | ||||||||||
1 Gb NICs | ||||||||||
N2XX-ABPCI03-M3 | Broadcom 5709 Quad Port 1Gb w/TOE iSCSI for M3 Servers | Half | ||||||||
N2XX-ABPCI01-M3 | Broadcom 5709 Dual-Port Ethernet PCIe Adapter M3 & later | Half | ||||||||
UCSC-PCIE-IRJ45 | Intel i350 Quad Port 1Gb Adapter | Half | ||||||||
10 Gb NICs | ||||||||||
N2XX-AIPCI01 [2] | Intel X520 Dual Port 10Gb SFP+ Adapter | Half | ||||||||
UCSC-PCIE-ITG | Intel X540 Dual Port 10GBase-T Adapter | Half | ||||||||
UCSC-PCIE-QNICBT | QLogic QLE8442 dual-port 10Gbase-T NIC | Half | ||||||||
UCSC-PCIE-QNICSFP | QLogic QLE8442 dual-port 10G SFP+ NIC | Half | ||||||||
UCSC-PCIE-ID10GC | Intel X550-T2 dual-port 10GBase-T NIC | Half | ||||||||
UCSC-PCIE-ID10GF | Intel X710-DA2 dual-port 10G SFP+ NIC | Half | ||||||||
UCSC-PCIE-IQ10GF | Intel X710 quad-port 10G SFP+ NIC | Half | ||||||||
UCSC-PCIE-ID40GF | Intel XL710 dual-port 40G QSFP+ NIC | Half | ||||||||
10 Gb Converged Network Adapters (CNAs) | ||||||||||
UCSC-PCIE-E14102B | Emulex OCe14102B-UX dual-port 10G SFP+ with iSCSI, FCoE CNA | Half | ||||||||
UCSC-PCIE-E14102 | Emulex OCe14102-UX dual-port 10 GbE FCoE CNA | Half | ||||||||
UCSC-PCIE-Q8362 | Qlogic QLE8362 dual-port 10 GbE FCoE CNA | Half | ||||||||
Host Bus Adapters (HBAs) | ||||||||||
UCSC-PCIE-BS32GF | Broadcom LPe32000 Single-Port 32G FC HBA | Half | ||||||||
UCSC-PCIE-BD32GF | Broadcom LPe32002 Dual-Port 32G FC HBA | Half | ||||||||
UCSC-PCIE-QD32GF | Qlogic QLE2742 dual-port 32G FC HBA N2XX-AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA | Half | ||||||||
N2XX-AQPCI05 | Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA | Half | ||||||||
UCSC-PCIE-Q2672 | Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics N2XX-AEPCI05 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA | Half | ||||||||
N2XX-AEPCI05 | Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA | Half | ||||||||
UCSC-PCIE-E16002 | Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics | Half | ||||||||
UCS Storage Accelerators [3] | ||||||||||
UCSC-F-S13002 | UCS Rack PCIe Storage 1300 GB SanDisk SX350 Medium Endurance | Half | ||||||||
UCSC-F-S16002 | UCS Rack PCIe Storage 1600 GB SanDisk SX350 Medium Endurance | Half | ||||||||
UCSC-F-S32002 | UCS Rack PCIe Storage 3200 GB SanDisk SX350 Medium Endurance | Half | ||||||||
UCSC-F-S64002 | UCS Rack PCIe Storage 6400 GB SanDisk SX350 Medium Endurance | Full | ||||||||
UCS NVMe/PCie Add in Cards | ||||||||||
UCSC-F-H38001 | 3.8 TB NVMe/PCIe storage (HGST SN150) Read Intensive | Half | ||||||||
UCSC-NVME-H64003 | Cisco HHHL AIC 6.4T HGST SN260 NVMe Extreme Perf High Endurance | HHHL* | ||||||||
UCSC-NVME-H76801 | Cisco HHHL 7.7T HGST SN260 NVMe Extreme Perf Value Endurance | HHHL* | ||||||||
UCSC-NVME-H32003 | Cisco HHHL AIC 3.2T HGST SN260 NVMe Extreme Perf High Endurance | HHHL* | ||||||||
*HHHL= Half Height Half Length | ||||||||||
Footnote: | ||||||||||
[1] | The mLOM cards do not plug into any of the riser 1 or riser 2 card slots | |||||||||
[2] | The Intel X520 supports the following Cisco PIDs: UCS-SFP-1WLR and UCS-SFP-1WSR SFPs. Refer to the Intel X520 product brief for a full list of supported optics and cables | |||||||||
[3] | A maximum of two storage accelerator cards are supported if they are half height | |||||||||
[Approved Configurations] | - | |||||||||
[1-CPU Systems] | You can select up to one PCie option card (slot 1 for 1-CPU systems) | |||||||||
[2-CPU Systems] | You can select up to two PCie option cards (slots 1 and 2 for 2-CPU systems) | |||||||||
[Caveats] | - | |||||||||
[1] | A maximum of two storage accelerator cards are supported if they are half height | |||||||||
[2] | For 1-CPU systems: Only the full-height PCIe slot on riser 1 (slot 1) is supported — Only a single plug-in PCIe VIC card is supported and must be installed in slot 1 (the full-height slot). However, in addition to the one PCIe VIC card, you can also choose to install an mLOM VIC card. — If any of the Storage Accelerator cards are installed, they can be installed only in slot 1. | |||||||||
[3] | For 2-CPU systems: Both PCIe slots(slots 1 and 2) are supported — Two plug-in PCIe VIC cards can be installed in 2-CPU systems, using slots 1 and 2. In addition, you can order an mLOM VIC card, which is installed in the mLOM slot inside the chassis and thus have three VIC cards in operation at the same time. —If any of the Storage Accelerator cards are installed, they can be installed only in slot 1 |
Available Power Supply
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCSC-PSU1-770W | 770W AC power supply for C-Series Servers | |||||||||
UCSC-PSU1-1050W | 1050W AC power supply for C-Series servers | |||||||||
Footnote: | ||||||||||
[1] | The C220 M4 LFF server accommodates two power supplies. A lightly loaded server can operate from one 770 W AC power supply or one 1050 W DC power supply. A fully loaded server might need to be powered with two 770 W power supplies | |||||||||
[2] | In a two power supply server, both power supplies must be identical. |
Available Power Cords
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
R2XX-DMYMPWRCORD | No power cord (dummy PID to allow for a no power cord option) | |||||||||
CAB-N5K6A-NA | Power Cord, 200/240V 6A, North America | |||||||||
CAB-AC-L620-C13 | AC Power Cord, NEMA L6-20 - C13, 2M/6.5ft | |||||||||
CAB-C13-CBN | CABASY,WIRE,JUMPER CORD, 27" L, C13/C14, 10A/250V | |||||||||
CAB-C13-C14-2M | CABASY,WIRE,JUMPER CORD, PWR, 2 Meter, C13/C14,10A/250V | |||||||||
CAB-C13-C14-AC | CORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M | |||||||||
CAB-250V-10A-AR | Power Cord, 250V, 10A, Argentina 186571 2500 mm Cordset rating: 10 A, 250/500 V MAX Length: 8.2 ft Plug: EL 219 (IRAM 2073) Connector: EL 701 (IEC60320/C13) | |||||||||
CAB-9K10A-AU | Power Cord, 250VAC 10A 3112 Plug, Australia Plug: Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm 186580 Connector: EL 701C EL 210 (EN 60320/C15) (BS 1363A) 13 AMP fuse | |||||||||
SFS-250V-10A-CN | Power Cord, SFS, 250V, 10A, China | |||||||||
CAB-250V-10A-CN | AC Power Cord - 250V, 10A - PRC | |||||||||
CAB-9K10A-EU | Power Cord, 250VAC 10A CEE 7/7 Plug, EU Connector: VSCC15 Cordset rating: 10A/16 A, 250 V Length: 8 ft 2 in. (2.5 m) Plug: M2511 186576 | |||||||||
SFS-250V-10A-ID | Power Cord, SFS, 250V, 10A, India | |||||||||
SFS-250V-10A-IS | Power Cord, SFS, 250V, 10A, Israel | |||||||||
CAB-9K10A-IT | Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy Plug: I/3G (CEI 23-16) Connector C15M (EN60320/C15 ) Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) 186575 | |||||||||
CAB-9K10A-SW | Power Cord, 250VAC 10A MP232 Plug, Switzerland Plug: MP232-R Cordset rating: 10 A, 250 V Length: 8 ft. 2 in (2.5 m) 186578 Connector: IEC 60320 C15 | |||||||||
CAB-9K10A-UK | Power Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK | |||||||||
CAB-9K12A-NA | Power Cord, 125VAC 13A NEMA 5-15 Plug, North America | |||||||||
CAB-250V-10A-BR | Power Cord - 250V, 10A - Brazil | |||||||||
CAB-48DC-40A-8AWG | Power Cord for -48VDC PSU, 3.5M, 3 Wire, 8AWG, 4 | |||||||||
CAB-JPN-3PIN | Power Cord 3PIN, Japan | |||||||||
CAB-C19-C20-3M-JP | Power Cord C19-C20, 3M/10ft Japan PSE mark |
Available NIC Mode (Optional)
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCSC-DLOM-01 | Dedicated Mode BIOS setting for C-Series Servers | |||||||||
UCSC-CCARD-01 | Cisco Card Mode BIOS setting for C-Series Servers | |||||||||
Footnote: | ||||||||||
[1] | By default, the C220 M4 server NIC mode is configured to be Shared LOM Extended. This NIC mode allows any LOM port or adapter card port to be used to access the Cisco Integrated Management Controller (CIMC). The Cisco VIC card must be installed in a slot with NCSI support. | |||||||||
[2] | To change the default NIC mode to Dedicated, select the UCSC-DLOM-01 PID shown in Table Above. In Dedicated NIC mode, the CIMC can be accessed only through the dedicated management port. | |||||||||
[3] | To change the default NIC mode to Cisco Card Mode, select the UCSC-CCARD-01 PID shown in Table Above. In this mode, you can assign an IP address to the CIMC using DHCP and from there you can fully automate your deployment. |
Cisco SD Card Module (Optional)
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCS-SD-128G | 128 GB SD Card for UCS Servers | |||||||||
UCS-SD-64G-S | 64 GB SD Card for UCS Servers | |||||||||
UCS-SD-32G-S | 32 GB SD Card for UCS Servers | |||||||||
Footnote: | ||||||||||
[1] | Order one or two matching SD cards. See Figure 5 on page 73 for the location of the mini storage module connector, which accommodates an SD module. Each SD module accommodates two SD cards. | |||||||||
[Caveats] | - | |||||||||
[1] | Install either one or two SD cards | |||||||||
[2] | Do not mix SD card sizes | |||||||||
[3] | You cannot mix SD cards with an internal M.2 SATA SSD |
Spare Parts List
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCSC-HS-C220M4= | Heat sink for UCS C220 M4 rack servers | |||||||||
UCS-CPU-GREASE3= | M4 Server CPU thermal grease syringe - needed for heatsink seal | |||||||||
UCS-CPU-CVR-EP-M4= | CPU load plate dust cover (for unpopulated CPU sockets) | |||||||||
UCSX-HSCK= | UCS Processor Heat Sink Cleaning Kit For Replacement of CPU | |||||||||
UCSC-PCI-2A-220M4= | C220 M4 PCIe Riser 1&2 Assy | |||||||||
UCSC-PCI-2C-220M4= | C220 M4 PCIe Riser 3 (HBA) | |||||||||
UCSC-PCIF-01H= | PCIe Low Profile blanking panel for UCS C-Series Server | |||||||||
UCSC-PCIF-01F= | PCIe Full Height blanking panel for UCS C-Series Server | |||||||||
UCSC-BBLKD-L | 3.5-inch HDD blanking panel [1] | |||||||||
UCSC-MLOM-BLK= | MLOM blanking panel | |||||||||
UCSC-RAILF-M4= | Tool-Less Friction Rail Kit for C220 M4 rack servers | |||||||||
UCSC-CMAF-M4= | Reversible CMA for C220 M4 friction & ball bearing rail kits | |||||||||
UCSC-RAILB-M4= | Tool-Less Ball Bearing Rail Kit for C220 M4 and C220 M4 rack servers | |||||||||
UCSC-FAN-C220M4= | C220 M4 Fan Module (one) | |||||||||
UCSC-BAFF-C220M4= | C220 M4 Air Baffle, Plastic Kit | |||||||||
N20-BKVM= | KVM cable for Server console port | |||||||||
UCSC-PSU-BLKP1U= | Power Supply Blanking Panel for C220 M4 servers | |||||||||
UCS-220CBLSR4= | C220 M4 SATA/SW RAID cable (1) for 4 HDD backplane chassis2 | |||||||||
UCS-220CBLMR4= | C220 M4 RAID controller cable (1) for 4HDD bckpln chassis2 | |||||||||
UCSC-EARS-C220M4= | C200 M4 rack ears kit (two ears) | |||||||||
Footnote: | ||||||||||
[1] | A drive blanking panel must be installed if you remove a disk drive from a UCS server. These panels are required to maintain system temperatures at safe operating levels, and to keep dust away from system components. | |||||||||
[2] | Required if ordering the RAID controller as a spare or to replace damaged cables |
PCIe Card Compatibility
PCIe Cards | Twinax Cables | Cisco SFP Modules | ||
---|---|---|---|---|
SFP-10G-SR | SFP-10G-LR | DS-SFP-FC8G-SW | ||
Converged Network Adapters (CNAs) | ||||
UCSC-PCIE-BSFP (Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI) | Yes | Yes | No | |
UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA) | Yes | Yes | Yes | No |
UCSC-PCIE-C10T-02 (Cisco VIC 1225T Dual Port 10GBaseT CNA) | No | No | No | No |
UCSC-MLOM-CSC-02 (Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+) | Yes | Yes | Yes | No |
UCSC-MLOM-C10T-02 (Cisco UCS VIC1227T VIC MLOM - Dual Port 10GBaseT) | No | No | No | No |
UCSC-PCIE-C40Q-02 (Cisco VIC 1285 Dual Port 40Gb QSFP CNA) | Yes | No [1] | No | |
UCSC-PCIE-C40Q-03 (Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA) | Yes | No [1] | No | |
UCSC-PCIE-ESFP (Emulex OCe11102-FX dual-port 10 GbE FCoE CNA (Gen 3 CNA)) | Yes | Yes | No | |
UCSC-PCIE-QSFP (QLogic QLE8242-CU dual-port 10 GbE FCoE CNA) | Yes | Use Qlogic SFP | ||
UCSC-PCIE-B3SFP (Broadcom 57810 10Gb A-FEX SFP+ | Yes | Yes | No | |
UCSC-PCIE-Q8362 (Qlogic QLE8362 dual-port 10 GbE FCoE CNA) | Yes | Use Qlogic SFP | ||
UCSC-PCIE-E14102 (Emulex OCe14102-UX dual-port 10 GbE FCoE CNA) | Yes | Yes | No | |
Network Interface Cards (NICs) | ||||
N2XX-ABPCI01-M3 (Broadcom 5709 Dual-Port Ethernet PCIe Adapter for M3 Servers) | Use RJ45 Ethernet cable | |||
N2XX-ABPCI03-M3 (Broadcom 5709 Quad Port 10/100/1Gb NIC w/TOE iSCSI for M3 Servers | Use RJ45 Ethernet cable | |||
N2XX-AIPCI01 (Intel X520 Dual Port 10Gb SFP+ Adapter) | Yes | Use Intel SFP UCS-SFP-1WLR or UCS-SFP-1WSR | ||
UCSC-PCIE-ITG (Intel X540 Dual Port 10GBase-T Adapter) | Use RJ45 Ethernet cable | |||
UCSC-PCIE-IRJ45 (Intel i350 Quad Port 1Gb Adapter | Use RJ45 Ethernet cable | |||
UCSC-PCIE-BTG(Broadcom 57712 Dual Port 10GBASE-T w/TOE iSCSI) | Yes | No | No | |
Host Bus Adapters (HBAs) | ||||
N2XX-AEPCI03 (Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA | No | Preinstalled - do not change SFP | ||
N2XX-AEPCI05 (Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA) | No | Preinstalled - do not change SFP | ||
N2XX-AQPCI03 (QLogic QLE2462 Dual Port 4Gb Fibre Channel HBA) | No | Preinstalled - do not change SFP | ||
N2XX-AQPCI05 (QLogic QLE2562 Dual Port 8Gb Fibre Channel HBA) | No | Preinstalled - do not change SFP | ||
UCSC-PCIE-Q2672 (Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics) | No | Preinstalled - do not change SFP | ||
UCSC-PCIE-E16002 (Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics) | No | Preinstalled - do not change SFP | ||
Footnotes: | ||||
[1] | This card supports a 4x10 Gbps QSFP to SFP breakout fiber cable. |