Please Upgrade Server
*This Configure to Order has not been created.
*You can still
Contact Us
for a quote on this server.
*Thank you.
The request has been sent.
Thank you.
Price as Configured:
$0
- Up to 2 Intel Xeon 6 processors
- 32 DDR5 DIMM slots – maximum memory 8 TB
- Five to seven system fans
- Up to 10 SFF, or 20 E#.S
- Up to three x16 PCIe Gen5
- OCP 3.0 support
- Up to 2 HPE power supplies
- NS204i-u boot device with 3 install option
- HPE iLO 7 management
- Up to 3 Single-Wide, low-profile GPUs
(Click to View)
Configure the HPE ProLiant Compute DL360 Gen12, a compact 1U 2P rack server built for hybrid cloud and enterprise workloads. Intel Xeon 6 processors (up to 144 cores) and up to 8 TB of DDR5 memory deliver up to 2x higher average compute performance versus prior generations, backed by flexible NVMe storage, up to three GPUs, three cooling options, and HPE iLO 7 management.
LFF P72174-B21
SFF P72175-B21
10SFF/20EDSFF P72176-B21
LFF Chassis Backplane Options
No Drives No ControllerP78963-B21
ODD USB to SATA Signal Cable KitP72199-B21
Display Port/USB Enablement KitP72229-B21
- The 4 LFFx1 12G SAS backplane is embedded as default in 4LFF CTO Server, and selecting one internal controller card is required as essential for SAS./SATA
SFF Chassis Backplane Options
8 SFF L-ShapedP75084-B21
2SFF Side by SideP75086-B21
ODD/Display Port/USB KitP72225-B21
- If P75084-B21 is selected, quantity 1 hardware controller must be selected for SAS/SATA/NVMe drives
- P72225-B21 can be selected without P75084-B21
SFF/EDSFF Chassis Backplane Options
2x SFF 24G x4 TriMode U.3 BCP72223-B21
4x E3.S 32G x4 NVMe backplaneP72221-B21
ODD/Display Port/USB KitP72227-B21
- Max 5 Boxes
- P72227-B21 locates at Box 4 and 5
- 24G x2/x4 TriMode U.3 can be mixed
- 32G x2/x4 NVMe (can be mixed)
NS204i-u Front KitP77198-B21
Primary OCP Box3P72596-B21
Secondary OCP Box3P72597-B21
- P77198-B21 locates at Box 5 with airflow vent hole
- Front OCP NIC(s) Enablement Kit is available at Box 3, max quantity 2
- P72597-B21 cannot be selected without installation of second processor
- Front OCP installed, Bezel kit cannot be selected.
The Intel® Xeon® 6 series of processors offers both E-Core and P-Core processors. Mixing of CPUs is not supported.
Xeon E-CoresThe Intel® Xeon® 6 series single threaded processor stack is comprised entirely of efficiency cores (E-Cores) providing ultra-high core counts optimized for power efficient operations.
• Optimized for single-threaded workloads
• Up to 144 cores at 330 W TDP
• 6400 MT/s DDR5 memory
• Up to four 24 GT/s UPI 2.0
• PCIe 5.0 with up to 88 lanes per CPU
• Security features (SGX)
Xeon P-CoresThe Intel® Xeon® 6 series processor stack is comprised entirely of performance cores (P-Cores), providing high core counts optimized for power and performance.
• Optimized for multi-threaded applications and workloads
• Up to 86 cores at 350 W TDP
• 6400 MT/s DDR5 memory
• Up to four 24 GT/s UPI 2.0
• PCIe 5.0 with up to 88 lanes per CPU
• Security features (SGX)
GPU Server requires Rich I/O CPU to support sufficient PCIe lanes for PCIe slots and drive cages.
Standard Heat SinkP48904-B21
High-performance Heat SinkP74787-B21
Air Baffle KitP84549-B21
- STD Heat Sink: CPU<=185W
-
Performance Heatsink
- HPR Heat Sink: CPU 186W-350W (1CPU/2CPUs)
- NVMe/ SAS4
- 100GbE or above Networking/ InfiniBand
- 256GB DIMM
- Rear NS204i-u V2
- Nvidia L4 GPU.
- 7x 4056 dual-rotor Performance Fan must be selected

Requirment if the follwoing are installed:
- CPU < 271W (1x CPU)
- 100GbE or above Networking/ InfiniBand
- 256GB DIMM
- Rear NS204i-u V2
- Nvidia L4 GPU.
Upgrade Parts:
- P82009-B21 - Upgrade Heat Sink Kit
- P82559-B21 - Upgrade Fan Kit
- P82626-B21 - Upgrade Handle Tool Kit
In the CL LC bundle Kit, with full-speed the 4028 Fan Kit runs at 210W, which requires 42W additional power than DL360 Gen12 Performance 4056 Fan Kitd
7x 4028 single-rotor Performance Fan are embedded

Installed Slots:
- 1. P79273-B21 - Cold Plate Module from NS204 PCIe Slot3
- 2. P74208-B21 - Cold Plate Module from PCIe
- P62046-B21 - Quick Disconnect Tube Set
DLC Required if these are installed:
- NVMe/ SAS4
- 100GbE or above Networking/ InfiniBand
- 256GB DIMM
- Rear NS204i-u V2
- Nvidia L4 GPU.
- If DLC is installed : Mandatory P62046-B21
The P74208-B21 or P79273-B21 contains qty 2x Cold Plate Modules (Heat sinks)and qty 1x Quick Disconnect Module.
7x 4056 single-rotor Performance Fan are embedded
Standard Fan Kit (qty 5)P48907-B21
Standard Fan Kit (qty 2)P54697-B21
High Performance Fan Kit (qty 7)P48908-B21
- P82559-B21 - Closed-loop Liquid Cooling Field Upgrade Fan Kit
- In the CL LC bundle Kit, with full-speed the 4028 Fan Kit runs at 210W, which requires 42W additional power than DL360 Gen12 Performance 4056 Fan Kit

Max 1
- P78279-B21 - V2 480GB NVMe
- P81160-B21 - V2 960GB NVMe
- P81162-B21 - V2 960GB NVMe SED
Front EnablementP77198-B21
- 10SFF/20EDSFF Chassis
- Front Cage Box5
- Hot-plug
Internal EnablementP72595-B21
- All CTO
- Internal
- Not Hot-plug
Rear EnablementP72197-B21
- All CTO
- PCIe Slot 2
- Hot-plug
The NS204i-u will take up PCIe Slot 2 space only. The PCIe Slot 1 (FHHL) and PCIe Slot 3 (to be Low Profile) are available in the system with the selection of optional “HPE ProLiant Compute DL360 Gen11 x16 LP Riser Kit (P48903-B21)”.
The MR (MegaRAID) and SR (Smart Array) controller families use different management tools and cannot be installed together in the same server. With a tri-mode U.3 backplane, both series support SAS, SATA, and NVMe drives, allowing mixed drive types in one system. This server has no built-in hardware RAID, so a storage controller is required for any RAID functionality — direct-attached SATA drives without one run in AHCI mode only.
SR Series (SmartRAID)SR Series
Installation Service Manual
The SR series on this server is limited to one option: HPE Smart Array E208e-p SR Gen10
Type-p (PCIe plug-in) form factor only
8 external SAS lanes, no cache — used for connecting external SAS storage, not internal drive management
No battery or capacitor required (no cache to protect)
MR Series (MegaRAID) - View PDFMR Series
Installation Service Manual
Available in type-o (OCP) and type-p (PCIe plug-in) form factors
Flash-Backed Write Cache (FBWC), requiring a separate energy pack (battery or hybrid capacitor)
MR932i-p (900 series): PCIe Gen5, up to 32 SAS/NVMe drives, onboard battery included
MR200/400 series supports SAS/SATA HDD and SSD only — no NVMe
Choosing Between MR and SR
- HPE MR200/400 RAID controllers support SAS & SATA drives
- MR932i-p supports NVMe
- Need OCP slot deployment → MR type-o only
- Simple RAID, no cache needed → MR216i-o or MR216i-p
- Need cache, moderate drive count → MR408i-o or MR416i-o/p
- Maximum drive count or throughput → MR932i-p
- External SAS storage → E208e-p (Gen10, type-p, external only, no cache)
What is Intel® VROC (Virtual RAID on CPU)?
Intel® VROC (Virtual RAID on CPU) is a software-based RAID solution for direct-attached NVMe SSDs, run through the CPU instead of a hardware storage controller.
- Requires the server boot mode to be set to UEFI Mode
- RAID support is disabled by default — enabled and configured through UEFI System Utilities (not supported in Intelligent Provisioning)
- Requires an Intel VROC driver (OS-specific) and a VROC Hybrid RAID license to enable NVMe RAID
- All drives in a VROC RAID volume must share the same interface and form factor
- Managed via UEFI System Utilities, Intel VROC GUI/CLI (Windows), or mdadm CLI (Linux)
- Intel VROC Premium — R7J59AAE (E-RTU), R7J57A (FIO Software): RAID 0, 1, 5, 10; up to 32 NVMe drives depending on processor
- Intel VROC RAID 1 — S3Q39AAE (E-RTU), S3Q19A (FIO Software): RAID 1 only; up to 32 NVMe drives depending on processor
- SATA drives not supported by either license

Installed Slots:
- P72596-B21 - Front Primary OCP NIC Box3 Bay3
- P72597-B21 - Front Secondary OCP NIC Box3 Bay1
OCP Notes:
- P72597-B21 cannot be selected if the P72596-21 is not selected.
- P72597-B21 cannot be selected without installation of second processor.
- CPU1 can support Slot 14 OCP A with x8 PCIe 5.0 as default, no cable connection is required
- CPU1 can support Slot 14 OCP A with x16 PCIe 5.0 with selection of “P72201-B21, CPU1 to Rear OCP SlotA x16 Cable Kit”.
- Or CPU1 can support Slot 15 OCP B with x8 PCIe 5.0 with selection of “P72203-B21, CPU1 to Rear OCP SlotB x8 Cable Kit”.
- Slot 15 OCP B: x16 PCIe 5.0 (Requires 2nd CPU)
Please Upgrade Server
*This Configure to Order has not been created.
*You can still
Contact Us
for a quote on this server.
*Thank you.
The request has been sent.
Thank you.
Price as Configured:
$0
Base Standard Capabilities
| Processor type | Intel |
|---|---|
| Processor family | Intel® Xeon® 6 Scalable processors |
| Processor number | 1 or 2 |
| Processor core available | 8 to 144 core, depending on processor |
| Processor speed | 4.0 GHz maximum, depending on processor |
| Processor cache | 48 MB to 336 MB L3 cache, depending on processor |
| Memory type | HPE DDR5 Smart Memory |
| Maximum memory | 8 TB with 256 GB DDR5 |
| Memory slots | 32 DDR5 DIMM slots (16 per processor) |
| Memory protection features | On-Die ECC (Error Correction Code) designed to correct bit errors within the DRAM |
| Accelerators | 3 Single-wide GPU in rear |
| System fan features | Standard Fan Kit (Q'ty 5), Standard Fan Kit (Q'ty 2) for 2nd Processor, High performance Fan Kit (Q'ty 7), Close Loop Liquid Cooling Heatsink & Fan kit, Direct Liquid Cooling Solution. |
| Expansion slots | Maximum 3 PCIe Gen5 slots (x16 lanes/each) & Maximum 2 OCP3.0 slots (x16 lanes/each) |
| Form factor | 1U Rack |
| Network controller | Optional - Minimum 1 to be selected. Wide range of speeds, cabling, chipsets and form factors (PCIe stand-up adapter and OCP3.0 in rear/front). Please see QuickSpecs for network card choices. |
| Storage controller | Optional - HPE ProLiant Compute Smart Array Gen12 Storage Controller in variety of protocols — including PCIe Gen5, NVMe, port count, array utilities, and form factors (PCIe stand-up adapter and OCP3.0). Optional - Intel® VROC Hybrid RAID for NVMe. Optional - HPE ProLiant Compute Gen12 OS Boot Device, in rear or front accessible or internal. Please see QuickSpecs for storage controllers selection. |
| Drive supported | Up to 4 LFF SAS/SATA HDDs or SSDs, optional 1 OS Boot device (internal, external accessible from rear wall); Up to 8+2 SFF SAS/SATA HDDs or SATA/SAS/NVMe U.3 SSDs, optional 1 OS Boot device (internal, external accessible from rear wall); Up to 10 SFF/20 E3.S to be mixed, optional 1 OS Boot Device (internal, external accessible from rear wall or front cage), optional 2 front OCP NICs |
| Optical drive type | Optional - HPE 9.5 mm SATA DVD-RW Optical Drive, HPE Mobile USB DVD-RW Drive. |

































