Current Configuration
(List below serves as quick links to each section)
Chassis
Processors
Backplane for SFF Chassis
Backplane for SFF/EDSFF Chassis
Heat Sink
Closed Loop Liquid Cooling - CL LC
Direct Liquid Cooling - DLC
Memory
Fans
Boot Options
LFF
SFF
NVMe
Drives EDSFF
Storage Controller
Networking
OCP 3.0
Host Bus Adapter
Riser Options
Optical Disk Drive
Power Supply Unit
Rail Kit
ECS Warranty
The request has been sent.
Thank you.
Price as Configured:
$0
Price as Configured:
$0
- Up to 2 Intel Xeon 6 processors
- 32 DDR5 DIMM slots – maximum memory 8 TB
- Five to seven system fans
- Up to 10 SFF, or 20 E#.S
- Up to three x16 PCIe Gen5
- OCP 3.0 support
- Up to 2 HPE power supplies
- NS204i-u boot device with 3 install option
- HPE iLO 7 management
- Up to 3 Single-Wide, low-profile GPUs
(Click to View)
Configure the HPE ProLiant Compute DL360 Gen12, a compact 1U 2P rack server built for hybrid cloud and enterprise workloads. Intel Xeon 6 processors (up to 144 cores) and up to 8 TB of DDR5 memory deliver up to 2x higher average compute performance versus prior generations, backed by flexible NVMe storage, up to three GPUs, three cooling options, and HPE iLO 7 management.
LFF P72174-B21
SFF P72175-B21
10SFF/20EDSFF P72176-B21
LFF Chassis Backplane Options
No Drives No ControllerP78963-B21
ODD USB to SATA Signal Cable KitP72199-B21
Display Port/USB Enablement KitP72229-B21
- The 4 LFFx1 12G SAS backplane is embedded as default in 4LFF CTO Server, and selecting one internal controller card is required as essential for SAS./SATA
SFF Chassis Backplane Options
8 SFF L-ShapedP75084-B21
2SFF Side by SideP75086-B21
ODD/Display Port/USB KitP72225-B21
- If P75084-B21 is selected, quantity 1 hardware controller must be selected for SAS/SATA/NVMe drives
- P72225-B21 can be selected without P75084-B21
SFF/EDSFF Chassis Backplane Options
2x SFF 24G x4 TriMode U.3 BCP72223-B21
4x E3.S 32G x4 NVMe backplaneP72221-B21
ODD/Display Port/USB KitP72227-B21
- Max 5 Boxes
- P72227-B21 locates at Box 4 and 5
- 24G x2/x4 TriMode U.3 can be mixed
- 32G x2/x4 NVMe (can be mixed)
NS204i-u Front KitP77198-B21
Primary OCP Box3P72596-B21
Secondary OCP Box3P72597-B21
- P77198-B21 locates at Box 5 with airflow vent hole
- Front OCP NIC(s) Enablement Kit is available at Box 3, max quantity 2
- P72597-B21 cannot be selected without installation of second processor
- Front OCP installed, Bezel kit cannot be selected.
The Intel® Xeon® 6 series of processors offers both E-Core and P-Core processors. Mixing of CPUs is not supported.
Xeon E-CoresThe Intel® Xeon® 6 series single threaded processor stack is comprised entirely of efficiency cores (E-Cores) providing ultra-high core counts optimized for power efficient operations.
• Optimized for single-threaded workloads
• Up to 144 cores at 330 W TDP
• 6400 MT/s DDR5 memory
• Up to four 24 GT/s UPI 2.0
• PCIe 5.0 with up to 88 lanes per CPU
• Security features (SGX)
Xeon P-CoresThe Intel® Xeon® 6 series processor stack is comprised entirely of performance cores (P-Cores), providing high core counts optimized for power and performance.
• Optimized for multi-threaded applications and workloads
• Up to 86 cores at 350 W TDP
• 6400 MT/s DDR5 memory
• Up to four 24 GT/s UPI 2.0
• PCIe 5.0 with up to 88 lanes per CPU
• Security features (SGX)
GPU Server requires Rich I/O CPU to support sufficient PCIe lanes for PCIe slots and drive cages.
Standard Heat SinkP48904-B21
High-performance Heat SinkP74787-B21
Air Baffle KitP84549-B21
- STD Heat Sink: CPU<=185W
- Performance Heatsink
- HPR Heat Sink: CPU 186W-350W (1CPU/2CPUs)
- NVMe/ SAS4
- 100GbE or above Networking/ InfiniBand
- 256GB DIMM
- Rear NS204i-u V2
- Nvidia L4 GPU.
- 7x 4056 dual-rotor Performance Fan must be selected

Requirment if the follwoing are installed:
- CPU < 271W (1x CPU)
- 100GbE or above Networking/ InfiniBand
- 256GB DIMM
- Rear NS204i-u V2
- Nvidia L4 GPU.
Upgrade Parts:
- P82009-B21 - Upgrade Heat Sink Kit
- P82559-B21 - Upgrade Fan Kit
- P82626-B21 - Upgrade Handle Tool Kit
In the CL LC bundle Kit, with full-speed the 4028 Fan Kit runs at 210W, which requires 42W additional power than DL360 Gen12 Performance 4056 Fan Kitd
7x 4028 single-rotor Performance Fan are embedded

Installed Slots:
- 1. P79273-B21 - Cold Plate Module from NS204 PCIe Slot3
- 2. P74208-B21 - Cold Plate Module from PCIe
- P62046-B21 - Quick Disconnect Tube Set
DLC Required if these are installed:
- NVMe/ SAS4
- 100GbE or above Networking/ InfiniBand
- 256GB DIMM
- Rear NS204i-u V2
- Nvidia L4 GPU.
- If DLC is installed : Mandatory P62046-B21
The P74208-B21 or P79273-B21 contains qty 2x Cold Plate Modules (Heat sinks)and qty 1x Quick Disconnect Module.
7x 4056 single-rotor Performance Fan are embedded
Standard Fan Kit (qty 5)P48907-B21
Standard Fan Kit (qty 2)P54697-B21
High Performance Fan Kit (qty 7)P48908-B21
- P82559-B21 - Closed-loop Liquid Cooling Field Upgrade Fan Kit
- In the CL LC bundle Kit, with full-speed the 4028 Fan Kit runs at 210W, which requires 42W additional power than DL360 Gen12 Performance 4056 Fan Kit

Max 1
- P78279-B21 - V2 480GB NVMe
- P81160-B21 - V2 960GB NVMe
- P81162-B21 - V2 960GB NVMe SED
Front EnablementP77198-B21
- 10SFF/20EDSFF Chassis
- Front Cage Box5
- Hot-plug
Internal EnablementP72595-B21
- All CTO
- Internal
- Not Hot-plug
Rear EnablementP72197-B21
- All CTO
- PCIe Slot 2
- Hot-plug
The NS204i-u will take up PCIe Slot 2 space only. The PCIe Slot 1 (FHHL) and PCIe Slot 3 (to be Low Profile) are available in the system with the selection of optional “HPE ProLiant Compute DL360 Gen11 x16 LP Riser Kit (P48903-B21)”.
The MR (MegaRAID) and SR (Smart Array) controller families use different management tools and cannot be installed together in the same server. With a tri-mode U.3 backplane, both series support SAS, SATA, and NVMe drives, allowing mixed drive types in one system. This server has no built-in hardware RAID, so a storage controller is required for any RAID functionality — direct-attached SATA drives without one run in AHCI mode only.
SR Series (SmartRAID)SR Series
Installation Service Manual
The SR series on this server is limited to one option: HPE Smart Array E208e-p SR Gen10
Type-p (PCIe plug-in) form factor only
8 external SAS lanes, no cache — used for connecting external SAS storage, not internal drive management
No battery or capacitor required (no cache to protect)
MR Series (MegaRAID) - View PDFMR Series
Installation Service Manual
Available in type-o (OCP) and type-p (PCIe plug-in) form factors
Flash-Backed Write Cache (FBWC), requiring a separate energy pack (battery or hybrid capacitor)
MR932i-p (900 series): PCIe Gen5, up to 32 SAS/NVMe drives, onboard battery included
MR200/400 series supports SAS/SATA HDD and SSD only — no NVMe
Choosing Between MR and SR
- HPE MR200/400 RAID controllers support SAS & SATA drives
- MR932i-p supports NVMe
- Need OCP slot deployment → MR type-o only
- Simple RAID, no cache needed → MR216i-o or MR216i-p
- Need cache, moderate drive count → MR408i-o or MR416i-o/p
- Maximum drive count or throughput → MR932i-p
- External SAS storage → E208e-p (Gen10, type-p, external only, no cache)
What is Intel® VROC (Virtual RAID on CPU)?
Intel® VROC (Virtual RAID on CPU) is a software-based RAID solution for direct-attached NVMe SSDs, run through the CPU instead of a hardware storage controller.
- Requires the server boot mode to be set to UEFI Mode
- RAID support is disabled by default — enabled and configured through UEFI System Utilities (not supported in Intelligent Provisioning)
- Requires an Intel VROC driver (OS-specific) and a VROC Hybrid RAID license to enable NVMe RAID
- All drives in a VROC RAID volume must share the same interface and form factor
- Managed via UEFI System Utilities, Intel VROC GUI/CLI (Windows), or mdadm CLI (Linux)
- Intel VROC Premium — R7J59AAE (E-RTU), R7J57A (FIO Software): RAID 0, 1, 5, 10; up to 32 NVMe drives depending on processor
- Intel VROC RAID 1 — S3Q39AAE (E-RTU), S3Q19A (FIO Software): RAID 1 only; up to 32 NVMe drives depending on processor
- SATA drives not supported by either license

Installed Slots:
- P72596-B21 - Front Primary OCP NIC Box3 Bay3
- P72597-B21 - Front Secondary OCP NIC Box3 Bay1
OCP Notes:
- P72597-B21 cannot be selected if the P72596-21 is not selected.
- P72597-B21 cannot be selected without installation of second processor.
- CPU1 can support Slot 14 OCP A with x8 PCIe 5.0 as default, no cable connection is required
- CPU1 can support Slot 14 OCP A with x16 PCIe 5.0 with selection of “P72201-B21, CPU1 to Rear OCP SlotA x16 Cable Kit”.
- Or CPU1 can support Slot 15 OCP B with x8 PCIe 5.0 with selection of “P72203-B21, CPU1 to Rear OCP SlotB x8 Cable Kit”.
- Slot 15 OCP B: x16 PCIe 5.0 (Requires 2nd CPU)
2 PCIe SlotsPrimary + Secondary FH riser
Includes: P75407-B21 + P72598-B21
2 PCIe Slots
Primary Slot 1: x16, Full-height.
Secondary Slot 3: x16, Full-height.
3 PCIe SlotsPrimary + Secondary Low Profile (LP) riser.
Includes: P75407-B21 + P48903-B21
3 PCIe Slots
Primary Slot 1: x16, Full-height.
Primary Slot 2: x16, Low-profile.
Secondary Slot 3: x16, Low-profile.
- All Secondary Risers Require 2nd Processor
- The Primary Riser Slot 1 & Slot 2 are rated for a maximum power draw of 75 W/ each.
- If rear hot-plug NS204i-u V2 is installed, the Slot 2 cage needs to be removed.
- P79273-B21 — DLC cold plate module from NS204 PCIe Slot 2. Takes over Slot 2.
- P74208-B21 — DLC cold plate module from PCIe Slot 3. Takes over Slot 3.
- All PCIe slots are featured with Wake-on-LAN (WoL)
- Silicon Root of Trust
- Firmware is signed with CNSA 2.0 approved algorithms
- Supports quantum-resistant (PQC) cryptography
- Continuous integrity checking and secure recovery
- Dedicated iLO network port
- iLO Service Port (USB) on the front for direct local access
- Remote console and virtual media
- RESTful API / Redfish support
- Integration with HPE Compute Ops Management and OneView
- Real-time server health monitoring
- Integrated Management Log (IML)
- Automatic detection of liquid cooling leaks (sends alerts and can force shutdown)
- Support for chassis intrusion detection
Current Configuration
(List below serves as quick links to each section)
Chassis
Processors
Backplane for SFF Chassis
Backplane for SFF/EDSFF Chassis
Heat Sink
Closed Loop Liquid Cooling - CL LC
Direct Liquid Cooling - DLC
Memory
Fans
Boot Options
LFF
SFF
NVMe
Drives EDSFF
Storage Controller
Networking
OCP 3.0
Host Bus Adapter
Riser Options
Optical Disk Drive
Power Supply Unit
Rail Kit
ECS Warranty
The request has been sent.
Thank you.
Price as Configured:
$0
Base Standard Capabilities
| Processor type | Intel |
|---|---|
| Processor family | Intel® Xeon® 6 Scalable processors |
| Processor number | 1 or 2 |
| Processor core available | 8 to 144 core, depending on processor |
| Processor speed | 4.0 GHz maximum, depending on processor |
| Processor cache | 48 MB to 336 MB L3 cache, depending on processor |
| Memory type | HPE DDR5 Smart Memory |
| Maximum memory | 8 TB with 256 GB DDR5 |
| Memory slots | 32 DDR5 DIMM slots (16 per processor) |
| Memory protection features | On-Die ECC (Error Correction Code) designed to correct bit errors within the DRAM |
| Accelerators | 3 Single-wide GPU in rear |
| System fan features | Standard Fan Kit (Q'ty 5), Standard Fan Kit (Q'ty 2) for 2nd Processor, High performance Fan Kit (Q'ty 7), Close Loop Liquid Cooling Heatsink & Fan kit, Direct Liquid Cooling Solution. |
| Expansion slots | Maximum 3 PCIe Gen5 slots (x16 lanes/each) & Maximum 2 OCP3.0 slots (x16 lanes/each) |
| Form factor | 1U Rack |
| Network controller | Optional - Minimum 1 to be selected. Wide range of speeds, cabling, chipsets and form factors (PCIe stand-up adapter and OCP3.0 in rear/front). Please see QuickSpecs for network card choices. |
| Storage controller | Optional - HPE ProLiant Compute Smart Array Gen12 Storage Controller in variety of protocols — including PCIe Gen5, NVMe, port count, array utilities, and form factors (PCIe stand-up adapter and OCP3.0). Optional - Intel® VROC Hybrid RAID for NVMe. Optional - HPE ProLiant Compute Gen12 OS Boot Device, in rear or front accessible or internal. Please see QuickSpecs for storage controllers selection. |
| Drive supported | Up to 4 LFF SAS/SATA HDDs or SSDs, optional 1 OS Boot device (internal, external accessible from rear wall); Up to 8+2 SFF SAS/SATA HDDs or SATA/SAS/NVMe U.3 SSDs, optional 1 OS Boot device (internal, external accessible from rear wall); Up to 10 SFF/20 E3.S to be mixed, optional 1 OS Boot Device (internal, external accessible from rear wall or front cage), optional 2 front OCP NICs |
| Optical drive type | Optional - HPE 9.5 mm SATA DVD-RW Optical Drive, HPE Mobile USB DVD-RW Drive. |

































