Current Configuration

(List below serves as quick links to each section)

Server Chassis

Processors

Bezel

Memory for 1st Gen Intel

Memory for 2nd Gen Intel

RAID Controllers

HDD (2.5") Drives

SSD (2.5") Drives

SSD U.2 NVMe Drives

PCIe Risers

Accelerator Options

Network Daughter Card

Boot Optimized Storage Subsystem (BOSS-S1):

Internal Dual SD Module (IDSDM)

Optical Drive

Rail Kit

Trusted Platform Module

iDRAC9 Remote Options

Power Supplies

ECS Warranty

The request has been sent.
Thank you.

Price as Configured:
$0

Error Submitting Cart. Please get in touch with us for support.

Please select all the mandatory items in the configuration list before submitting the cart.

One or more items in your cart has no price. This will be submitted as a "Request for a Quote".

Dell PowerEdge R940xa Rack Server | Configurable

 

READ ME

  • Some options may not be displayed until the compatible parent option is chosen ie. Chassis – Drives, Processor – RAM etc.
  • “Quote” items can be added to your cart and sent to us via the cart page
  • Click the blue bar to close/open a section from view after choosing your options

Server Chassis

Processors

Supports up to (4) processors

Intel Xeon Scalable

Supports up to 4 Processors

Intel 2nd Gen Xeon Scalable

Supports up to 4 Processors

Bezel (Optional)

LCD security bezel

Memory for 1st Gen Intel (Optional)

12 DIMMs per processor (up to 48 DIMMs in a 4-processor configuration)
RDIMMs and LRDIMMs must not be mixed.
NVDIMMs and LRDIMMs must not be mixed.
NVDIMMs and RDIMMs can be mixed.
Maximum of 12 NVDIMM-Ns can be installed in a system.
NVDIMM-Ns or RDIMMs must not be mixed with LRDIMMs.
Maximum of 24 PMem's can be installed in a system 4-Socket Configuration.
PMem is supported on systems with 1600W and 2400W PSU configuration.
PMem supports up to 4 NVMe hard drive (2.5-inches x 32 backplane).
PMem does not support GPU configuration.
Mixing of PMem operating modes (App Direct, Memory Mode) is not supported.
Please read the manual below for all Memory rules.

Memory for 2nd Gen Intel (Optional)

12 DIMMs per processor (up to 48 DIMMs in a 4-processor configuration)
RDIMMs and LRDIMMs must not be mixed.
NVDIMMs and LRDIMMs must not be mixed.
NVDIMMs and RDIMMs can be mixed.
Maximum of 12 NVDIMM-Ns can be installed in a system.
NVDIMM-Ns or RDIMMs must not be mixed with LRDIMMs.
Maximum of 24 PMem's can be installed in a system 4-Socket Configuration.
PMem is supported on systems with 1600W and 2400W PSU configuration.
PMem supports up to 4 NVMe hard drive (2.5-inches x 32 backplane).
PMem does not support GPU configuration.
Mixing of PMem operating modes (App Direct, Memory Mode) is not supported.
Please read the manual below for all Memory rules.

RAID Controllers (Optional)

Embedded S140 software RAID installed by default

HDD (2.5") Drives (Optional)

Supports up to (8), (28), or (32), Drives based on the configuration desired

SSD (2.5") Drives (Optional)

Supports up to (8), (28), or (32), Drives based on the configuration desired

SSD U.2 NVMe Drives (Optional)

Supports up to (4) Drives based on the configuration desired

PCIe Risers (Optional)

There are a lot of PCIe configurations please read the manuals below to make sure you are installing the correct card with the correct riser configurations.
If you need support please chat or call.

Accelerator Options (Optional)

Supports the following:
(4) double-width GPUs
or up to (4) double-width or (8) single-width FPGAs
All GPUs will need to be installed in the x16 Risers.
The FPGA can be installed in the x8 Risers.

Network Daughter Card (Optional)

Boot Optimized Storage Subsystem (BOSS-S1): (Optional)

PCI-e card with up to (2) M.2 SSD Drives

Internal Dual SD Module (IDSDM) (Optional)

Optical Drive (Optional)

Only for 8 bay chassis

Rail Kit (Optional)

Trusted Platform Module (Optional)

iDRAC9 Remote Options (Optional)

Default iDRAC9 Express

Power Supplies

Supports up to (4) AC or DC power supply units (PSUs).

ECS Warranty

Helpful Tip: Once desired configuration is selected click "Add to Cart".
From the cart page you can submit a submit a quote request for best pricing

Quick Specs
Form Factor:

4U rack server

Processor | Max: 112 Cores

Up to 4x 2nd Gen Intel Xeon Scalable

Memory | Max: 15.36TB

48 DDR4 RDIMM, LRDIMM 2933Mhz Max 6TB
Up to 12 NVDIMM, Max 384GB
Up to 24 Intel® Optane™ DC persistent memory PMem, max 12.28TB
(15.36TB max with PMem and LRDIMM)
Supports registered ECC DDR4 DIMMs only

Storage | Max: 245.76TB

Up to 8x 2.5” SAS SATA (HDD/SSD) max 61.44TB
Up to 24 x 2.5” SAS/SATA (HDD/SSD) max 184.32TB
Up to 32 SAS/SATA (HDD/SSD) with 4 NVME SSD max 245.76TB

Rear Storage:

None

Boot Options:

BOSS
USB
IDSDM (Virtualized Platforms only)

PCIe Slots | Gen 3.0

Up to 12 slots, (6x16 slots or 2x16 + 10x8 slots)

Remote management:

iDRAC9 with Lifecycle Controller

LOM / rNDC:

4 x 1GbE, 4 x 10GbE, 2 x 10GbE+2 x 1GbE, or 2 x 25GbE

RAID controllers:

S140 (SW RAID | SATA, NVMe)
PERC H330, H730, H730P, H740P, H750, H840
HBA330, HBA350, HBA355i, HBA355e, 12 Gbps SAS HBA

GPU:

Up to 4 double-width GPUs or
8 single-width full-height FPGAs


Ideal for:
  • Artificial Intelligence (AI)
  • Data Analytics
  • Machine Learning (ML)

The Dell PowerEdge R940xa pairs four CPUs with four GPUs in a 1:1 ratio to accelerate database performance and drive real-time decision-making. With up to 6TB of memory and four-socket compute power, it delivers fast, consistent response times — helping businesses scale on-premises capacity to reduce cloud costs and mitigate security risks.

Drive Configurations:

8 Bay Chassis - 8x2.5" SAS/SATA (HDD/SSD)
Supports the Front USB module and the ODD
32 Bay Chassis - 24x2.5" SAS/SATA (HDD/SSD) + 8x2.5" SAS/SATA (HDD/SSD)
32 Bay Chassis - 20x2.5" SAS/SATA (HDD/SSD) + 4x2.5" Universal SAS/SATA/NVMe (HDD/SSD) + 8x2.5" SAS/SATA (HDD/SSD)
This configuration includes the SAS Expander to support the NVMe front drives


The 32-bay configuration uses two separate backplanes — upper and lower. The upper backplane houses 24 slots and supports a SAS Expander accommodating up to 4 SAS/SATA or NVMe drives, while the lower backplane is limited to the 8-bay layout. Note that the 8-bay upper and lower backplanes differ significantly in drive layout.


Cooling Options:
Fans

The R940xa includes 6 hot-swap fans and offers 4 different air shroud options. If NVDIMMs are installed, the corresponding battery sits on top of the shrouds.

Integrated cooling fans dissipate heat generated during system operation, providing thermal support for processors, expansion cards, and memory modules.

The cooling fan assembly houses the full array of system fans; a failure in this cooling system can lead to server overheating and potential hardware damage.

Image of the Fan Installation for the R940xa Rack server
Memory Options

Each CPU offers 12 memory DIMM slots, totaling 48 DIMMs across the system, organized into six channels with 2 DIMMs per channel. For optimal performance, each CPU's memory channels should be populated evenly — with either 6 or 12 DIMMs per processor.

For complete rules and restrictions on each memory type, refer to the manuals below.

Image of the Dell PowerEdge R940 Memory



PCIe Configuration:

This system supports up to 12 PCIe slots, with slot width — x8 or x16 — depending on the riser installed. GPU installations require x16 risers, while single-wide FPGA cards can run on the x8 PCIe riser instead.

Image of the Riser PCIe slot numbers
Number of processors NVMe GPU Riser size Slot size Slot quantity Available slots Height Length
4 NA GPU Ready/ Double wide accelerators capable X16 PCIe Riser 1 x16 2 2, 4 FH FL
x8 1 5 FH HL
X16 PCIe Riser 2 x16 2 9, 11 FH FL
x8 1 12 FH HL
NA Non-GPU/ Single wide FPGA X8 PCIe Riser 1 x8 5 1, 2, 3, 4, 5 FH HL
X8 PCIe Riser 2 x8 5 8, 9, 10, 11, 12 FH HL
Front NVMe GPU Ready/ Double wide accelerators capable X16 PCIe Riser 1 x16 2 2, 4 FH FL
X16 PCIe Riser 2 x16 2 9, 11 FH FL
Front NVMe Non-GPU/ Single wide FPGA X8 PCIe Riser 1 x8 4 1, 2, 3, 4 FH HL
X8 PCIe Riser 2 x8 4 8, 9, 10, 11 FH HL
2 NA GPU Ready/ Double wide accelerators capable X16 PCIe Riser 1 x16 1 4 FH FL
X16 PCIe Riser 2 x16 1 11 FH FL
NA Non-GPU/ Single wide FPGA X8 PCIe Riser 1 x8 2 3, 4 FH HL
X8 PCIe Riser 2 x8 2 10, 11 FH HL
Networking:

With only 12 PCIe slots to work with, a dedicated rNDC slot helps preserve capacity while expanding networking options — upgrading from 1GbE to 10GbE, or running both simultaneously with a mixed FlexLOM, is fully supported.

The appropriate riser mounts above the rNDC; if no riser is installed, blanks must be fitted in its place.

Image of the dedicated Daughter Card Slot of the R940xa
Storage Controller:

The Dell PowerEdge R940xa rack server supports PERC 9, 10, and 11 storage controllers, along with three boot options — BOSS, IDSDM, and an internal USB drive — with the IDSDM typically favored for loading hypervisors in virtualization workloads.


Performance Level Controller & Description
Entry S140 (SATA, NVMe) SW RAID SATA
Value HBA330 (Internal), 12Gbps SAS HBA (External) Memory: None x8 12 Gb SAS x8 PCIe 3.0, H330, H350, 12Gbps SAS HBA (External), HBA355e (External) Memory: None x8 12 Gb SAS x8 PCIe 3.0, HBA350i
Value Performance H730P Memory: 2GB, NV 72-bit, 866MHz x8 12 Gb SAS x8 PCIe 3.0 , H750
Premium Performance H740P, 8x8 ROC Memory: 4/8GB, NV 72-bit
GPU:

Refer to the PCIe section above for details on the slot availability across each riser configuration.

A number of rules govern GPU and FPGA configurations on this system — refer to the manuals below for the complete list.

  • PMem does not support GPU configurations
  • 256 GB DIMMS do not support GPU configuration.
  • You Must install the GPU air shroud
  • The GPU card can be installed only in a X16 PCIe riser configuration.
  • The FPGA card is installed in the x8 Riser configuration.
Dell PowerEdge R940xa GPU
Power & Dimensions:
Power Supplies

The Dell PowerEdge R940xa supports 4 hot-swap power supply units, configurable in BIOS as either 2+2 for redundancy or 4+0 without redundancy when identical PSUs are installed. In redundant mode with Hot Spare disabled, power draws equally from both PSUs; enabling Hot Spare puts one PSU into sleep mode during low utilization to maximize efficiency.

AC (Platinum) AC (Titanium) DC Mix Mode/HVDC (China and Japan only)
1100 W 1600 W 2000 W 2400 W
750 W 1600 W 2600 W
1100 W Mix Mode: 750 W (for China only)
1100 W

Dimensions

Height: 174.3 mm (6.87”)
Width: 441.16 mm (17.37”)
Depth: 835.9mm (32.9”)
Weight: 56.0kg (123.5lbs.)
*Dimensions do not include bezel

Base Standard Capabilities

FeaturesTechnical specification
ProcessorUp to four 2nd Generation Intel® Xeon® Scalable processors, up to 28 cores each
Memory48 DDR4 DIMM slots, Supports RDIMM /LRDIMM, up to 2933MT/s, 6TB max
Up to 12 NVDIMM, 384GB Max
Up to 24 Intel® Optane™ DC persistent memory PMem, max 12.28TB, (15.36TB max with PMem and LRDIMM)
Supports registered ECC DDR4 DIMMs only
Storage controllersInternal Controllers: PERC H330, H730P, H740P, HBA330
External Controllers: H840, 12 Gbps SAS HBA
Software RAID:S140
Boot Optimized Storage Subsystem (BOSS):HWRAID 2 x M.2 SSDs 240GB, 480GB
Internal Dual SD Module
Drive baysFront bays:
  • Up to 8x 2.5” SAS SATA (HDD/SSD) max 61.44TB
  • Or up 24 x 2.5” SAS/SATA (HDD/SSD) max 184.32TB
  • Or up to 32 SAS/SATA (HDD/SSD) max 245.76TB
  • Or up to 32 SAS/SATA (HDD/SSD) with up to 4 NVME PCIe SSD max 245.76TB
Power suppliesGold:1100W - 48VDC
Platinum 1100W, 1600W, 2000W, 2400W
Hot plug power supplies with full redundancy option
6 hot plugs fans with N +1 redundancy
DimensionsForm factor: Rack (4U)
Height: 174.3 mm (6.87”)
Width: 441.16 mm (17.37”)
Depth: 835.9mm (32.9”)
Weight: 56.0kg (123.5lbs.)
*Dimensions do not include bezel
Embedded managementIPMI 2.0 compliant
iDRAC9,
iDRAC Direct,
Quick Sync 2 BLE/wireless
BezelOptional LCD bezel or security bezel
OpenManage SoftwareOpenManage Enterprise
OpenManage Mobile
OpenManage Power Center
Integrations and connectionsIntegrations:
Microsoft System Center
VMware vCenter
BMC Truesight
Red Hat Ansible Modules
Connections:
IBM Tivoli® Netcool/OMNIbus
Micro Focus Operations Manager i (OMi)
Nagios® Core
Nagios® XI
ToolsDell EMC Repository Manager
Dell EMC Update Package
Dell EMC System Update
Dell EMC Server Update Utility
iDRAC Service Module
iDRAC RESTful API with Redfish
OpenManage Server Administrator
OpenManage Storage Services
SecurityTPM 1.2/2.0 optional
Cryptographically signed firmware
Secure Root of Trust
Secure Boot
Secure Erase
System Lockdown (requires iDRAC Enterprise or Datacenter)
I/O & PortsNetwork daughter card options:
  • 4 x 1GbE
  • 4 x 10GbE
  • 2 x 10GbE + 2 x 1GbE
  • 2 x 25GbE
Front Ports:
  • 2 x USB 2.0
  • 1 x VGA
  • 1 x 1 x Dedicated iDRAC Direct Micro-USB
  • (Optional 1 x USB 3.0 only offered on the 8-drive configuration)
Rear Ports:
  • 1 x Dedicated iDRAC port
  • 1 x Serial
  • 2 x USB 3.0
  • 1 x VGA
Video card:
  • 2 x VGA
PCIe:
  • Up to 12 x Gen3 slots, (6x16 slots or 2x16 + 10x8 slots)
Accelerator OptionsUp to 4 doublewidth GPUs
Or up to 4 double-width full-height FPGAs
Or 8 single-width full-height FPGAs
Supported operating systemsCanonical® Ubuntu® LTS
Citrix® Hypervisor
Microsoft Windows Server® LTSC with Hyper-V
Oracle® Linux
Red Hat® Enterprise Linux
SUSE® Linux Enterprise Server
VMware® ESXi

Spec Sheet 4

Feature PowerEdge R940xa PowerEdge R930
Processor 4x 2nd Generation Intel Xeon Processor Scalable Family (Gold and Platinum) 4x Intel Xeon E5-5600 v3
CPU interconnect Intel Ultra Path Interconnect (UPI) Intel QuickPath Interconnect (QPI)
Memory ● 48x DDR4 RDIMM, LRDIMM, 12x NVDIMM
● Up to 6 TB with 48x 128 GB LRDIMM
● DCPMM 12.28 TB (15.36 TB with LRDIMM)
● 96 x DDR4 RDIMM, LRDIMM
● Up to 3 TB with 96x 32 GB LRDIMM
Disk Drives 2.5 inches - 12 Gb SAS, 6 Gb SATA 2.5 inches - 12 Gb SAS, 6 Gb SATA
Storage Controllers Adapters: HBA330, H330, H350, H730P, H740P, H750, 12G SAS HBA, H840, HBA350i and HBA355e
SW RAID: S140
12 Gbps PERC-9 series
PCIe SSD Up to 4x PCIe SSD 8x PCIe SSD with dedicated slots using two extender cards.
PCIe Slots Max 12 PCIe 3.0 Max 10 PCIe 3.0
rNDC 4x 1 GB, 4x 10 GB, 2x 10 GB+2x 1 GB, or 2x 25 GB 4x 1 Gb, 4x 10 Gb, or 2x 10 Gb+2x 1 Gb
Accelerators Up to 4 double-width GPUs or up to 4 doublewidth or up to 8 single-width FPGAs. Not Available
USB Ports Front: 2 ports (USB 2.0), 1 managed (micro-usb) Rear: 2 ports (USB 3.0) Internal: 1 port (USB 3.0) Optional: 1 Front port (USB 3.0) - only offered on 8-drive configuration Front: 2 ports (USB 2.0) Rear: 2 ports (USB 2.0) Internal: 1 port (USB 2.0)
Rack Height 4U 4U
Power Supplies ● AC (Platinum): 750 W, 1100 W, 1600 W, 2000 W, 2400 W
● Mix Mode: 750 W PSU (DC input for China only)
● AC (Titanium): 750 W, 1600 W, 2600 W
● DC: 1100 W
● Mix Mode/HVDC: 750 W (for China only), 1100 W
● AC: 750 W, 1100 W
● DC: 1100 W
● Mix Mode/HVDC: 750 W
System Management Lifecycle Controller 3.x, OpenManage, QuickSync2.0, OMPC3, Digital License Key, iDRAC Direct (dedicated micro-USB port), Easy Restore, vFlash Lifecycle Controller 2.x, OpenManage, Digital License Key, iDRAC QuickSync, iDRAC Direct, Easy Restore
Availability ● Hot-plug Drives
● Hot-plug Redundant Cooling
● Hot-plug Redundant Power Supplies
● IDSDM
● Hot-plug Drives
● Hot-plug Redundant Cooling
● Hot-plug Redundant Power Supplies
● IDSDM