Base Standard Capabilities
Capability / Feature | Description |
---|---|
Chassis | Two rack unit (2RU) chassis |
CPU | One or two 2nd Generation Intel® Xeon® scalable family CPUs |
Chipset | Intel® C621 series chipset |
Memory | 24 slots for registered DIMMs (RDIMMs), load-reduced DIMMs (LRDIMMs), or through silicon via (TSV) DIMMs and support for Intel® Optane™ Persistent Memory (PMem) |
Multi-bit Error Protection | This server supports multi-bit error protection. |
Video | The Cisco Integrated Management Controller (CIMC) provides video using the Matrox G200e video/graphics controller:
|
Power subsystem | Up to two of the following hot-swappable power supplies:
|
Front Panel | A front panel controller provides status indications and control buttons. |
ACPI | This server supports the advanced configuration and power interface (ACPI) 6.2 standard. |
Fans | Six hot-swappable fans for front-to-rear cooling |
Infiniband | The InfiniBand architecture is supported by the PCIe slots. |
Expansion slots | Up to six PCIe slots (on two riser cards)
|
Internal storage devices |
|
I/O Interfaces |
|
Storage controller |
|
Modular LAN on Motherboard (mLOM) slot | The dedicated mLOM slot on the motherboard can flexibly accommodate the following cards:
|
Integrated management processor | Baseboard Management Controller (BMC) running Cisco Integrated Management Controller (CIMC) firmware. Depending on your CIMC settings, the CIMC can be accessed through the 1GE dedicated management port, the 1GE/10GE LOM ports, or a Cisco virtual interface card (VIC). CIMC manages certain components within the server, such as the Cisco 12G SAS HBA. |
UCSM | Unified Computing System Manager (UCSM) runs in the Fabric Interconnect and automatically discovers and provisions some of the server components. |
Tech Specs
Parameter | Value |
---|---|
Height | 3.43 in. (87.1 mm) |
Width (including slam latches) | 17.57 in.(446.3 mm) Including handles: 18.96 in (481.5 mm) |
Depth | 29.56 in. (750.8 mm) Including handles: 30.44 in (773.1 mm) |
Front Clearance | 3 in. (76 mm) |
Side Clearance | 1 in. (25 mm) |
Rear Clearance | 6 in. (152 mm) |
Weight Below | Weight does not include outer rail, which is attached to the rack. |
Maximum (12 front HDDs, 2 rear HDDS, 2 CPUs, 24 DIMMs, 2 power supplies) | 66.0 lbs (29.0 kg) |
Minimum (1 HDD, 1 CPU, 1 DIMM, 1 power supply) | 41.5 lbs (18.8 kg) |
Bare (0 HDD, 0 CPU, 0 DIMM, 1 power supply) | 38.8 lbs (17.6 kg) |
Server Diagram
ID | Description |
---|---|
(Click to enlarge) | |
1 | Front-facing drive bays. |
2 | Cooling Fan modules (six, hot-swappable) |
3 | DIMM sockets on motherboard (up to 12 per CPU; total 24). Not visible under air baffle in this view. |
4 | CPUs and heatsinks (one or two). Not visible under air baffle in this view |
5 | Supercap power module (RAID backup battery) mounting location on air baffle |
6 | Internal, vertical USB 3.0 port on motherboard |
7 | Mini storage module socket Supports either an SD card carrier with two SD card slots; or an M.2 SSD carrier with two slots for either two M.2 SATA or two M.2 NVMe SSDs. |
8 | Chassis intrusion switch (optional) |
9 | PCIe cable connectors for NVMe SSDs, only on these PCIe riser 2 options:
|
10 | Rear-drive backplane assembly |
11 | Power supplies (hot-swappable, redundant as 1+1). |
12 | Rear 2.5-inch drive bays: |
13 | Trusted platform module (TPM) socket on motherboard (not visible in this view) |
14 | PCIe riser 2 (PCIe slots 4, 5, 6), with the following options:
|
15 | Micro-SD card socket on PCIe riser 1 |
16 | PCIe riser 1 (PCIe slot 1, 2, 3), with the following options:
|
17 | Modular LOM (mLOM) card bay on chassis floor (x16 PCIe lane), not visible in this view |
18 | Cisco modular RAID controller PCIe slot (dedicated slot) |
19 | RTC battery on motherboard (not visible in this view) |
20 | Securing clips for GPU cards on air baffle |
Rear View
(Click to enlarge) | |
ID | Description |
---|---|
1 | PCIe riser 1 (slots 1, 2, 3) Two options:
|
2 | PCIe riser 2 (slots 4, 5, 6) Four options:
|
3 | Rear 2.5-inch drive bays:
|
4 | Power supplies (two, redundant as 1+1) |
5 | Screw holes for dual-hole grounding lug |
6 | Modular LAN-on-motherboard (mLOM) card slot (x16) |
7 | USB 3.0 ports (two) |
8 | Dual 1/10 GB Ethernet ports (LAN1, LAN2) LAN1 is left connector, LAN2 is right connector |
9 | VGA video port (DB-15 connector) |
10 | 1-Gb Ethernet dedicated management port |
11 | Serial port (RJ-45 connector) |
12 | Rear Unit Identification button/LED |
Riser Cards (Required)
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
PCIe Riser 1 required | ||||||||||
UCSC-PCI-1-C240M5 | Riser 1. Includes 3 PCIe slots (x8, x16, x8). Slots 1 and 2 controlled with CPU1 | |||||||||
UCSC-PCI-1B-240M5 | Riser 1B. Includes 3 PCIe slots (x8, x8, x8). All slots controlled with CPU1. | |||||||||
UCSC-RIS-1-240M5 | Riser 1 3PCIe slots (x8, x16, x8) | |||||||||
UCSC-RIS-1B-240M5 | Riser 1B 3PCIe slots (x8, x8, x8) | |||||||||
PCIe Riser 2 options (all slots controlled with CPU2) | ||||||||||
UCSC-PCI-2A-240M5 | Riser 2A. Includes 3 PCIe slots (x16, x16, x8) and supports a GPU. | |||||||||
UCSC-PCI-2B-240M5 | Riser 2B. Includes 3 PCIe slots (x8, x16, x8) plus 1 NVMe connector (controls two rear SFF NVMe drives) and supports a GPU. | |||||||||
UCSC-PCI-2C-240M5 | Riser 2C. Includes 3 PCIe slots (x8, x8, x8) plus 2 NVMe connectors (one connector for two front SFF NVMe drives and one connector for two rear SFF NVMe drives). | |||||||||
UCSC-RIS-2A-240M5 | Riser 2A 3PCIe slots (x8, x16, x16) supports GPU, For T4 | |||||||||
UCSC-RIS-2B-240M5 | Riser 2B 3PCIe slot(x8, x16, x8) supports GPU+rear NVMe, For T4 | |||||||||
UCSC-RIS-2C-240M5 | Riser 2C 3PCIe slots (3 x8) supports front+rear NVMe, For T4 | |||||||||
Footnote: | ||||||||||
[1] | Riser 1 is required to be ordered | |||||||||
[2] | If no riser 2 option is selected, a riser blanking panel will be installed that covers PCIe slots 4, 5, and 6. You will not be able to install any PCIe cards in PCIe slots 4, 5, or 6 if the riser 2 option is not selected. You can order a spare riser 2 blanking panel (UCSC-PCIF-240M5=) | |||||||||
[3] | If there is any PCIe slot that does not have a card installed, you must order a blanking panel for that slot (UCSC-PCIF-01F=). |
Available CPU's
Product ID (PID) | Clock Freq (GHz) | Power (W) | Cache Size (MB) | Cores | UPI1 Links (GT/s) | Highest DDR4 DIMM Clock Support (MHz)2 | Workload/Processor type | |||
---|---|---|---|---|---|---|---|---|---|---|
Cisco Recommended CPUs3 (2nd Generation Intel® Xeon® Processors) | ||||||||||
UCS-CPU-I8276 | 2.2 | 165 | 38.5 | 28 | 3 SAP | 2933 | Oracle, SAP | |||
UCS-CPU-I8260 | 2.4 | 165 | 35.75 | 24 | 3 Azure Stack | 2933 | Microsoft Azure Stack | |||
UCS-CPU-I6262V | 1.9 | 135 | 33 | 24 | 3 Server infrastructure | 2400 | Virtual Server infrastructure or VSI | |||
UCS-CPU-I6248R | 3 | 205 | 35.75 | 24 | 2 | 2933 | - | |||
UCS-CPU-I6248 | 2.5 | 150 | 27.5 | 20 | 3 Oracle, SQL, | 2933 | VDI, Oracle, SQL, Microsoft Azure Stack | |||
UCS-CPU-I6238R | 2.2 | 165 | 38.5 | 28 | 2 SAP (2-Socket | 2933 | Oracle, SAP (2-Socket TDI only), Microsoft AzureStack | |||
UCS-CPU-I6238 | 2.1 | 140 | 30.25 | 22 | 3 | 2933 | SAP | |||
UCS-CPU-I6230R | 2.1 | 150 | 35.75 | 26 | 2 Server Infrastructure, | 2933 | Virtual Server Infrastructure, Data Protection, Big Data, Splunk, Microsoft AzureStack | |||
UCS-CPU-I6230 | 2.1 | 125 | 27.5 | 20 | 3 Data, Virtualization | 2933 | Big Data, Virtualization | |||
UCS-CPU-I5220R | 2.2 | 125 | 35.75 | 24 | 2 Server Infrastructure, | 2666 | Virtual Server Infrastructure, Splunk, Microsoft Azure Stack | |||
UCS-CPU-I5220 | 2.2 | 125 | 24.75 | 18 | 2 | 2666 | HCI | |||
UCS-CPU-I5218R | 2.1 | 125 | 27.5 | 20 | 2 Server Infrastructure, | 2666 | Virtual Server Infrastructure, Data Protection, Big Data, Splunk, Scale-out Object Storage, Microsoft AzureStack | |||
UCS-CPU-I5218 | 2.3 | 125 | 22 | 16 | 2 Microsoft Azure | 2666 | Virtualization, Microsoft Azure Stack, Splunk, Data Protection | |||
UCS-CPU-I4216 | 2.1 | 100 | 22 | 16 | 2 Protection, Scale | 2400 | Data Protection, Scale Out Storage | |||
UCS-CPU-I4214R | 2.4 | 100 | 16.5 | 12 | 2 Protection, Splunk, | 2400 | Data Protection, Splunk, Scale-out Object Storage, Microsoft AzureStack | |||
UCS-CPU-I4214 | 2.2 | 85 | 16.5 | 12 | 2 Protection, Scale | 2400 | Data Protection, Scale Out Storage | |||
UCS-CPU-I4210R | 2.4 | 100 | 13.75 | 10 | 2 Server Infrastructure, | 2400 | Virtual Server Infrastructure, Data Protection, Big Data, Splunk | |||
UCS-CPU-I4210 | 2.2 | 85 | 13.75 | 10 | 2 Big Data, | 2400 | Virtualization, Big Data, Splunk | |||
8000 Series Processor | ||||||||||
UCS-CPU-I8280L | 2.7 | 205 | 38.5 | 28 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I8280 | 2.7 | 205 | 38.5 | 28 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I8276L | 2.2 | 165 | 38.5 | 28 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I8276 | 2.2 | 165 | 38.5 | 28 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I8270 | 2.7 | 205 | 35.75 | 26 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I8268 | 2.9 | 205 | 35.75 | 24 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I8260Y | 2.4 | 165 | 35.75 | 24/20/16 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I8260L | 2.3 | 165 | 35.75 | 24 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I8260 | 2.4 | 165 | 35.75 | 24 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I8253 | 2.2 | 125 | 22 | 16 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
6000 Series Processor | ||||||||||
UCS-CPU-I6262V | 1.9 | 135 | 33 | 24 | 3 Gen Intel® | 2400 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6258R | 2.7 | 205 | 38.5 | 28 | 2 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6254 | 3.1 | 200 | 24.75 | 18 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6252N | 2.3 | 150 | 35.75 | 24 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6252 | 2.1 | 150 | 35.75 | 24 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6248R | 3 | 205 | 35.75 | 24 | 2 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6248 | 2.5 | 150 | 27.5 | 20 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6246R | 3.4 | 205 | 35.75 | 16 | 2 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6246 | 3.3 | 165 | 24.75 | 12 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6244 | 3.6 | 150 | 24.75 | 8 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6242R | 3.1 | 205 | 35.75 | 20 | 2 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6242 | 2.8 | 150 | 22 | 16 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6240R | 2.4 | 165 | 35.75 | 24 | 2 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6240Y | 2.6 | 150 | 24.75 | 18/14/8 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6240L | 2.6 | 150 | 24.75 | 18 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6240 | 2.6 | 150 | 24.75 | 18 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6238R | 2.2 | 165 | 38.5 | 28 | 2 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6238L | 2.1 | 140 | 30.25 | 22 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6238 | 2.1 | 140 | 30.25 | 22 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6234 | 3.3 | 130 | 24.75 | 8 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6230R | 2.1 | 150 | 35.75 | 26 | 2 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6230N | 2.3 | 125 | 27.5 | 20 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6230 | 2.1 | 125 | 27.5 | 20 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6226R | 2.9 | 150 | 22 | 16 | 2 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6226 | 2.7 | 125 | 19.25 | 12 | 3 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I6222V | 1.8 | 115 | 27.5 | 20 | 3 Gen Intel® | 2400 | 2nd Gen Intel® Xeon® | |||
5000 Series Processor | ||||||||||
UCS-CPU-I5222 | 3.8 | 105 | 16.5 | 4 | 2 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I5220S | 2.6 | 125 | 19.25 | 18 | 2 Gen Intel® | 2666 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I5220R | 2.2 | 150 | 35.75 | 24 | 2 Gen Intel® | 2666 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I5220 | 2.2 | 125 | 24.75 | 18 | 2 Gen Intel® | 2666 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I5218R | 2.1 | 125 | 27.5 | 20 | 2 Gen Intel® | 2666 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I5218B | 2.3 | 125 | 22 | 16 | 2 Gen Intel® | 2933 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I5218N | 2.3 | 105 | 22 | 16 | 2 Gen Intel® | 2666 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I5218 | 2.3 | 125 | 22 | 16 | 2 Gen Intel® | 2666 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I5217 | 3 | 115 | 11 | 8 | 2 Gen Intel® | 2666 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I5215L | 2.5 | 85 | 13.75 | 10 | 2 Gen Intel® | 2666 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I5215 | 2.5 | 85 | 13.75 | 10 | 2 Gen Intel® | 2666 | 2nd Gen Intel® Xeon® | |||
4000 Series Processor | ||||||||||
UCS-CPU-I4216 | 2.1 | 100 | 22 | 16 | 2 Gen Intel® | 2400 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I4215R | 3.2 | 130 | 11 | 8 | 2 Gen Intel® | 2400 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I4215 | 2.5 | 85 | 11 | 8 | 2 Gen Intel® | 2400 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I4214R | 2.4 | 100 | 16.5 | 12 | 2 Gen Intel® | 2400 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I4214Y | 2.2 | 85 | 16.5 | 12/ 10 8 | 2 Gen Intel® | 2400 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I4214 | 2.2 | 85 | 16.5 | 12 | 2 Gen Intel® | 2400 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I4210R | 2.4 | 100 | 13.75 | 10 | 2 Gen Intel® | 2400 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I4210 | 2.2 | 85 | 13.75 | 10 | 2 Gen Intel® | 2400 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I4208 | 2.1 | 85 | 11 | 8 | 2 Gen Intel® | 2400 | 2nd Gen Intel® Xeon® | |||
3000 Series Processor | ||||||||||
UCS-CPU-I3206R | 1.9 | 85 | 11 | 8 | 2 Gen Intel® | 2133 | 2nd Gen Intel® Xeon® | |||
UCS-CPU-I3204 | 1.9 | 85 | 8.25 | 6 | 2 Gen Intel® | 2133 | 2nd Gen Intel® Xeon® | |||
Footnote: | ||||||||||
[1] | UPI = Ultra Path Interconnect. 2-socket servers support only 2 UPI performance, even if the CPU supports 3 UPI. | |||||||||
[2] | If higher or lower speed DIMMs are selected than what is shown for a given CPU speed, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock. | |||||||||
[Extra Notes] | Approved Configurations | |||||||||
[1] | DIMM only configurations: Select one or two identical CPUs listed | |||||||||
[2] | DIMM/PMem Mixed Configurations You must select two identical CPUs listed | |||||||||
[Caveats] | The selection of 1 or 2 CPUs depends on the desired server functionality. See the following sections: Memory, RAID Controllers, Drives, PCIe Option Card(s) | |||||||||
[1] | See MEMORY, for details on the compatibility of CPUs and DIMM speeds. |
Memory and Mirroring Modes
Product ID (PID) | PID Description | Voltage | Ranks/DIMM | Capacity | memory type | speed | ||||
---|---|---|---|---|---|---|---|---|---|---|
UCS-ML-256G8RT-H | 256 GB DDR4-2933MHz LRDIMM/8Rx4/1.2v | 1.2V | 8 | 256 | DDR4 | 2933 MHz | ||||
UCS-ML-128G4RT-H [1] | 128 GB DDR4-2933MHz LRDIMM/4Rx4 (16Gb) | 1.2V | 4 | 128 | DDR4 | 2933 MHz | ||||
UCS-ML-X64G4RT-H [1] | 64 GB DDR4-2933MHz LRDIMM/4Rx4 (8Gb) | 1.2V | 4 | 64 | DDR4 | 2933 MHz | ||||
UCS-MR-X64G2RT-H [1] | 64 GB DDR4-2933MHz RDIMM/2Rx4 (16Gb) | 1.2V | 2 | 64 | DDR4 | 2933 MHz | ||||
UCS-MR-X32G2RT-H [1] | 32GB DDR4-2933MHz RDIMM/2Rx4 (8Gb) | 1.2V | 2 | 32 | DDR4 | 2933 MHz | ||||
UCS-MR-X16G1RT-H [1] | 16 GB DDR4-2933MHz RDIMM/1Rx4 (8Gb) | 1.2V | 1 | 16 | DDR4 | 2933 MHz | ||||
UCS-ML-128G4RW [2] | 128GB DDR4-3200MHz LRDIMM 4Rx4 (16Gb) | 1.2V | 1 | 128 | DDR4 | 3200 MHz | ||||
UCS-MR-X64G2RW [2] | 64GB DDR4-3200MHz RDIMM 2Rx4 (16Gb) | 1.2V | 1 | 64 | DDR4 | 3200 MHz | ||||
UCS-MR-X32G2RW [2] | 32GB DDR4-3200MHz RDIMM 2Rx4 (8Gb) | 1.2V | 1 | 32 | DDR4 | 3200 MHz | ||||
UCS-MR-X16G1RW [2] | 16GB DDR4-3200MHz RDIMM 1Rx4 (8Gb) | 1.2V | 1 | 16 | DDR4 | 3200 MHz | ||||
Intel® Optane™ Persistent Memory Product | ||||||||||
UCS-MP-128GS-A0 | Intel® Optane™ Persistent Memory, 128GB, 2666 MHz | - | - | 128 | - | 2666 MHz | ||||
UCS-MP-256GS-A0 | Intel® Optane™ Persistent Memory, 256GB, 2666 MHz | - | - | 256 | - | 2666 MHz | ||||
UCS-MP-512GS-A0 | Intel® Optane™ Persistent Memory, 512GB, 2666 MHz | - | - | 512 | - | 2666 MHz | ||||
Intel® Optane™ Persistent Memory Product Operational Modes | ||||||||||
UCS-DCPMM-AD | Intel® Optane™ Persistent Memory - App Direct Mode | - | - | - | - | - | ||||
UCS-DCPMM-MM | Intel® Optane™ Persistent Memory - Memory Mode | - | - | - | - | - | ||||
Memory Mirroring Option | ||||||||||
N01-MMIRROR | Memory mirroring option | - | - | - | - | - | ||||
Memory Modes | ||||||||||
App Direct Mode | PMem operates as a solid-state disk storage device. Data is saved and is non-volatile. Both PMem and DIMM capacity counts towards CPU tiering (both PMem and DIMM capacities count towards the CPU capacity limit) | - | - | - | - | - | ||||
Memory Mode | PMem operates as a 100% memory module. Data is volatile and DRAM acts as a cache for PMem. Only PMem capacity counts towards CPU tiering (only the PMem capacity counts towards the CPU capacity limit). This is the factory default mode. | - | - | - | - | - | ||||
Mix Mode | DRAM as cache. Only PMem capacity counts towards CPU tiering (only the PMem capacity counts towards the CPU capacity limit) | - | - | - | - | - | ||||
Footnote: | ||||||||||
[1] | The available memory for the C220 M5 SFF is as follows: | |||||||||
[2] | Clock speed: Up to 2933 MHz | |||||||||
[3] | Rank per DIMM: 1, 2, 4, or 8 | |||||||||
[4] | Operational voltage: 1.2 V | |||||||||
[5] | Registered ECC DDR4 DIMMS (RDIMMs), Load-reduced DIMMs (LRDIMMs), or Intel® Optane™ Persistent Memory Modules (PMem) | |||||||||
[6] | Memory is organized with six memory channels per CPU, with up to two DIMMs per channel, as shown here. | |||||||||
[7] | Select the memory configuration and whether or not you want the memory mirroring option. The available memory DIMMs and mirroring option are listed above | |||||||||
[8] | When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. | |||||||||
[9] | Memory will operate at the maximum speed of the Intel Xeon Scalable processor memory controller, ranging from 2133 MHz to 2933 MHz for M5 servers. Check CPU specifications for supported speeds | |||||||||
[10] | For Memory Mode, the Intel-recommended DIMM to PMem capacity ratio in the same CPU channel is from 1:2 to 1:16. So if you use a 128 GB DIMM in a channel, you could use a 512 GB PMem for a 1:6 capacity ratio. If you use a 32 GB DIMM in a channel, you could use a 512 GB PMem for a 1:16 capacity ratio. There are several other combinations possible |
RAID Controller Options
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Controllers for Internal Drives Note that if the following Cisco 12G SAS RAID controller or Cisco 12G SAS HBA controller is selected, it is factory-installed in the dedicated internal slot. | ||||||||||
UCSC-RAID-M5 | Cisco 12G SAS RAID Controller with 2GB FBWC
| |||||||||
UCSC-SAS-M5 | Cisco 12G Modular SAS HBA
| |||||||||
Controller for External Drives | ||||||||||
UCSC-9400-8E | Cisco 12G 9400-8e 12G SAS HBA for external JBOD attach. You can install up to two of these and place them in the rear PCIe slots. | |||||||||
RAID Configuration Options (not available for Cisco 12G SAS HBA or embedded software RAID) | ||||||||||
R2XX-SRAID0 | Enable Single Disk Raid 0 Setting | |||||||||
R2XX-RAID0 | Factory preconfigured RAID striping option Enable RAID 0 Setting. Requires a minimum of one hard drive. | |||||||||
R2XX-RAID1 | Factory preconfigured RAID mirroring option Enable RAID 1 Setting. Requires exactly two drives with the same size, speed, capacity. | |||||||||
R2XX-RAID5 | Factory preconfigured RAID option Enable RAID 5 Setting. Requires a minimum of three drives of the same size, speed, capacity. | |||||||||
R2XX-RAID6 | Factory preconfigured RAID option Enable RAID 6 Setting. Requires a minimum of four drives of the same size, speed, capacity. | |||||||||
R2XX-RAID10 | Factory preconfigured RAID option Enable RAID 10 Setting. Requires a even number of drives (minimum of four drives) of the same size, speed, capacity. | |||||||||
Footnote: | ||||||||||
[1] | Although RAID levels 50 and 60 are not orderable from the factory, they are supported for selected controllers as shown above | |||||||||
[2] | For Cisco SAS 9400-8e 12G SAS HBA external drive enclosure support | |||||||||
[Approved Configurations] | - | |||||||||
[1] | The Cisco 12G SAS RAID controller upgrade option supports up to 14 internal drives with RAID 0, 1, 5, 6, 10, 50, 60, and JBOD mode support. | |||||||||
[2] | The Cisco 12G SAS HBA supports up to 14 internal drives with JBOD support. | |||||||||
[3] | The external drive PCIe controller card is the Cisco 12G 9400-8e SAS HBA. Up to two of these can be installed simultaneously with the Cisco 12G SAS Modular RAID controller card (UCSC-RAID-M5)or Cisco 12 Gbps Modular SAS HBA (UCSC-SAS-M5). |
Available Hot-Pluggable Sled-Mounted Front Facing Drives
Product ID (PID) | PID Description | Drive Type | Capacity | |||||||
---|---|---|---|---|---|---|---|---|---|---|
HDDs | ||||||||||
HDDs (10K RPM) | ||||||||||
UCS-HY18TB10K4KN [1] | 1.8 TB 12G SAS 10K RPM LFF HDD (4K) | SAS | 1.8 TB | |||||||
UCS-HY12TB10K12N | 1.2 TB 12G SAS 10K RPM LFF HDD | SAS | 1.2 TB | |||||||
HDDs (7.2K RPM) | ||||||||||
UCS-HD2T7KL12N | 2 TB 12G SAS 7.2K RPM LFF HDD | SAS | 2 TB | |||||||
UCS-HD4T7KL12N | 4 TB 12G SAS 7.2K RPM LFF HDD | SAS | 4 TB | |||||||
UCS-HD6T7KL4KN | 6 TB 12G SAS 7.2K RPM LFF HDD (4K) | SAS | 6 TB | |||||||
UCS-HD8T7K4KAN | 8 TB 12G SAS 7.2K RPM LFF HDD (4K) | SAS | 8 TB | |||||||
UCS-HD10T7K4KAN | 10 TB 12G SAS 7.2K RPM LFF HDD (4K) | SAS | 10 TB | |||||||
UCS-HD10T7KLEM | 10 TB 12G SAS 7.2K RPM LFF HDD (512e) | SAS | 10 TB | |||||||
UCS-HD12T7KL4KN | 12TB-12G SAS 7.2K RPM LFF HDD(4K) | SAS | 12 TB | |||||||
UCS-HD14T7KL4KN | 14TB 12G SAS 7.2K RPM LFF HDD(4K) | SAS | 14 TB | |||||||
UCS-HD16TW7KL4KN | 16TB 12G SAS 7.2K RPM LFF HDD(4K) | SAS | 16 TB | |||||||
UCS-HD18TW7KL4KN | 18TB 12G SAS 7.2K RPM LFF HDD(4K) | SAS | 18 TB | |||||||
UCS-HD14TT7KL4KN | 14TB 12G SAS 7.2K RPM LFF HDD(4K) | SAS | 14 TB | |||||||
UCS-HD16T7KL4KN | 16TB 12G SAS 7.2K RPM LFF HDD(4K) | SAS | 16 TB | |||||||
UCS-HD8T7K6GAN | 8 TB 6G SATA 7.2K RPM LFF HDD (512e) | SATA | 8 TB | |||||||
UCS-HD10T7K6GAN | 10TB 6G SATA 7.2K RPM LFF HDD (512e) | SATA | 10 TB | |||||||
UCS-HD12T7KL6GN | 12 TB 6G SATA 7.2K RPM LFF HDD (512e) | SATA | 12 TB | |||||||
Enterprise Performance SSDs (High endurance, supports up to 10X or 3X DWPD (drive writes per day)) [2] | ||||||||||
SAS SSDs | ||||||||||
UCS-HY800GK3X-EP | 800GB 3.5in Enterprise Performance 12G SAS SSD(3X endurance) | SAS | 800 GB | |||||||
UCS-HY16TK3X-EP | 1.6TB 3.5in Enterprise Performance 12G SAS SSD(3X endurance) | SAS | 1.6 TB | |||||||
SATA SSDs | ||||||||||
UCS-HY480G63X-EP | 480GB 3.5in Enterprise performance 6GSATA SSD(3X endurance S4600/S4610) | SATA | 480 GB | |||||||
UCS-HY960G63X-EP | 960GB 3.5in Enterprise performance 6GSATA SSD(3X endurance S4600/S4610) | SATA | 960 GB | |||||||
UCS-HY19T63X-EP | 1.9TB 3.5in Enterprise performance 6GSATA SSD(3X endurance S4600/S4610) | SATA | 1.9 TB | |||||||
Enterprise Value SSDs (Low endurance, supports up to 1X DWPD (drive writes per day))3 | ||||||||||
SATA SSDs | ||||||||||
UCS-HY240G61X-EV | 240 GB 3.5 inch Enterprise Value 6G SATA SSD (Samsung PM863A/PM883) | SATA | 240 GB | |||||||
UCS-HY480G61X-EV | 480 GB 3.5 inch Enterprise Value 6G SATA SSD (Intel 3520) | SATA | 480 GB | |||||||
UCS-HY960G61X-EV | 960 GB 3.5 inch Enterprise Value 6G SATA SSD (Samsung PM863A/PM883) | SATA | 960 GB | |||||||
UCS-HY19TM1X-EV | 1.9TB 3.5 inch Enterprise Value 6G SATA SSD | SATA | 1.9 TB | |||||||
Self-Encrypted Drives (SED) [4] | ||||||||||
UCS-HD4T12GNK9 | 4 TB 7.2K rpm LFF HDD (SED) FIPS140-2 | SAS | 4 TB | |||||||
UCS-HD6T12GANK9 | 6 TB 7.2K rpm LFF HDD (4K format, SED) FIPS140-2 | SAS | 6 TB | |||||||
UCS-HD12T7KL4NK9 | 12TB 7.2k rpm LFF HDD 4K format SED FIPS140-2 | SAS | 12 TB | |||||||
UCS-HY600G15NK9 | 600 GB 12G SAS 15K RPM LFF HDD (SED) FIPS140-2 | SAS | 600 GB | |||||||
PCIe/NVMe SFF (2.5-inch) drives [5] [6] | ||||||||||
UCSC-NVMEHY-H800 | 800 GB HGST SN200 NVMe High Perf. High Endurance (HGST) | NVMe | 800 GB | |||||||
UCS-NVMEHY-W1600 | 1.6TB 3.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance | NVMe | 1.6 TB | |||||||
UCS-NVMEHY-W3200 | 3.2TB 3.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance | NVMe | 3.2 TB | |||||||
Footnote: | ||||||||||
[NOTE:] | Cisco uses solid state drives from a number of vendors. All solid state drives are subject to physical write limits and have varying maximum usage limitation specifications set by the manufacturer. Cisco will not replace any solid state drives that have exceeded any maximum usage specifications set by Cisco or the manufacturer, as determined solely by Cisco. | |||||||||
[1] | Operating Systems supported on 4K sector size drives are as follows:
| |||||||||
[2] | Targeted for write centric IO applications. Supports endurance of 10 or 3 DWPD (drive writes per day). Target applications are caching, online transaction processing (OLTP), data warehousing, and virtual desktop infrastructure (VDI). | |||||||||
[3] | Targeted for read centric IO applications. Supports endurance of 1 DWPD (drive write per day). Target applications are boot, streaming media, and collaboration. | |||||||||
[4] | For all self-encrypting drives (SED), standalone Management (CIMC) and UCSM is supported for configuring and managing local keys. SED drives can be managed with local and remote key management (third-party key management). | |||||||||
[5] | Two CPUs must be installed in order to include any number of SFF NVMe PCIe SSDs. If you choose one or two PCIe NVMe drives, drive slots 1 and 2 at the front of the chassis are reserved for these drives (see images above for drive slot numbering). With the UCSC-C240-M5SN, you can ONLY have NVME SSDs in front drive bays 1-8. | |||||||||
[6] | Except HGST, Intel and Western Digital (WD) NVMe drives can be mixed anywhere in a C240 M5. | |||||||||
[NOTE: ] | When retrofitting front facing drives with spare NVMe drives, you must order the following along with the spare drives:
| |||||||||
[Caveats] | - | |||||||||
[2] | 2.5-inch SFF NVMe drives are connected directly to the CPU, not managed by the RAID controller. | |||||||||
[3] | You can mix HDDs and SSDs as long as you keep all HDDs in their own RAID volume and all SSDs in their own RAID volume. | |||||||||
[4] | You can mix SAS HDDs and SAS/SATA SSDs when using the Cisco 12G SAS RAID Controller or Cisco 12G SAS HBA. | |||||||||
[5] | If you order any SFF NVMe drives, you must also order two CPUs. | |||||||||
[6] | Except HGST, Intel and Western Digital (WD) NVMe drives can be mixed anywhere in a C240 M5. | |||||||||
[7] | SED drives can be mixed with the non-SED drives in Table Above |
Available Hot-Pluggable Sled-Mounted Rear Facing Drives
Product ID (PID) | PID Description | Drive Type | Capacity | |||||||
---|---|---|---|---|---|---|---|---|---|---|
HDDs | ||||||||||
HDDs (15K RPM) | ||||||||||
UCS-HD300G15K12N | 300 GB 12G SAS 15K RPM SFF HDD | SAS | 300 GB | |||||||
UCS-HD600G15K12N | 600 GB 12G SAS 15K RPM SFF HDD | SAS | 600 GB | |||||||
UCS-HD900G15K12N | 900 GB 12G SAS 15K RPM SFF HDD | SAS | 900 GB | |||||||
HDDs (10K RPM) | ||||||||||
UCS-HD300G10K12N | 300 GB 12G SAS 10K RPM SFF HDD | SAS | 300 GB | |||||||
UCS-HD600G10K12N | 600 GB 12G SAS 10K RPM SFF HDD | SAS | 600 GB | |||||||
UCS-HD12TB10K12N | 1.2 TB 12G SAS 10K RPM SFF HDD | SAS | 1.2 TB | |||||||
UCS-HD18TB10K4KN | 1.8 TB 12G SAS 10K RPM SFF HDD (4K) | SAS | 1.8 TB | |||||||
UCS-HD24TB10K4KN | 2.4 TB 12G SAS 10K RPM SFF HDD (4K) | SAS | 2.4 TB | |||||||
HDDs (7.2K RPM) | ||||||||||
UCS-HD1T7K12N | 1 TB 12G SAS 7.2K RPM SFF HDD | SAS | 1 TB | |||||||
UCS-HD2T7K12N | 2 TB 12G SAS 7.2K RPM SFF HDD | SAS | 2 TB | |||||||
UCS-HD1T7K6GAN | 1 TB 6G SATA 7.2K RPM SFF HDD | SAS | 1 TB | |||||||
Enterprise Performance SSDs (High endurance, supports up to 10X or 3X DWPD (drive writes per day)) | ||||||||||
SAS SSDs | ||||||||||
UCS-SD800GK3X-EP | 800 GB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) | SAS | 800 GB | |||||||
UCS-SD16TK3X-EP | 1.6 TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) | SAS | 1.6 TB | |||||||
UCS-SD32TK3X-EP | 3.2 TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) | SAS | 3.2 TB | |||||||
UCS-SD800GS3X-EP | 800GB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) | SAS | 800 GB | |||||||
UCS-SD16TS3X-EP | 1.6TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) | SAS | 1.6 TB | |||||||
UCS-SD32TS3X-EP | 3.2TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) | SAS | 3.2 TB | |||||||
SATA SSDs | ||||||||||
UCS-SD960G63X-EP | 960GB 2.5in Enterprise performance 6GSATA SSD(3X endurance) | SATA | 960 GB | |||||||
UCS-SD19T63X-EP | 1.9TB 2.5in Enterprise performance 6GSATA SSD(3X endurance) | SATA | 1.9 TB | |||||||
UCS-SD480G63X-EP | 480GB 2.5 inch Enterprise performance 6GSATA SSD(3X endurance) | SATA | 480 GB | |||||||
UCS-SD19TM3X-EP | 1.9TB 2.5in Enterprise performance 6GSATA SSD(3X endurance) | SATA | 1.9 TB | |||||||
UCS-SD480GM3X-EP | 480GB 2.5in Enterprise Performance 6GSATA SSD(3X endurance) | SATA | 480 GB | |||||||
UCS-SD960GM3X-EP | 960GB 2.5in Enterprise performance 6GSATA SSD(3X endurance) | SATA | 960 GB | |||||||
Enterprise Value SSDs (Low endurance, supports up to 1X DWPD (drive writes per day)) | ||||||||||
SAS SSDs | ||||||||||
UCS-SD960GK1X-EV | 960 GB 2.5 inch Enterprise Value 12G SAS SSD | SAS | 960 GB | |||||||
UCS-SD19TK1X-EV | 1.9 TB 2.5 inch Enterprise Value 12G SAS SSD | SAS | 1.9 TB | |||||||
UCS-SD38TK1X-EV | 3.8 TB 2.5 inch Enterprise Value 12G SAS SSD | SAS | 3.8 TB | |||||||
UCS-SD76TK1X-EV | 7.6 TB 2.5 inch Enterprise Value 12G SAS SSD | SAS | 7.6 TB | |||||||
UCS-SD15TK1X-EV | 15.3 TB 2.5 inch Enterprise Value 12G SAS SSD | SAS | 15.3 TB | |||||||
UCS-SD960GS1X-EV | 960GB 2.5 inch Enterprise Value 12G SAS SSD | SAS | 960 GB | |||||||
UCS-SD19TS1X-EV | 1.9TB 2.5 inch Enterprise Value 12G SAS SSD | SAS | 1.9 TB | |||||||
UCS-SD38TS1X-EV | 3.8TB 2.5 inch Enterprise Value 12G SAS SSD | SAS | 3.8 TB | |||||||
SATA SSDs | ||||||||||
UCS-SD480G6I1X-EV | 480GB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500/S4150) | SATA | 480 GB | |||||||
UCS-SD960G6I1X-EV | 960GB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500/S4150) | SATA | 960 GB | |||||||
UCS-SD38T6I1X-EV | 3.8TB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500/S4150) | SATA | 3.8 TB | |||||||
UCS-SD120GM1X-EV | 120 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | SATA | 120 GB | |||||||
UCS-SD240GM1X-EV | 240 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | SATA | 240 GB | |||||||
UCS-SD480GM1X-EV | 480 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | SATA | 480 GB | |||||||
UCS-SD960G61X-EV | 960 GB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863A/PM883) | SATA | 960 GB | |||||||
UCS-SD960GM1X-EV | 960 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | SATA | 960 GB | |||||||
UCS-SD16TM1X-EV | 1.6 TB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | SATA | 1.6 TB | |||||||
UCS-SD19T61X-EV | 1.9 TB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863A/PM883) | SATA | 1.9 TB | |||||||
UCS-SD19TM1X-EV | 1.9 TB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | SATA | 1.9 TB | |||||||
UCS-SD38T61X-EV | 3.8 TB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863A/PM883) | SATA | 3.8 TB | |||||||
UCS-SD38TM1X-EV | 3.8 TB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | SATA | 3.8 TB | |||||||
UCS-SD76T61X-EV | 7.6 TB 2.5 inch Enterprise Value 6G SATA SSD | SATA | 7.6 TB | |||||||
UCS-SD76TM1X-EV | 7.6 TB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | SATA | 7.6 TB | |||||||
UCS-SD960G6S1X-EV | 960GB 2.5 inch Enterprise Value 6G SATA SSD | SATA | 960 GB | |||||||
UCS-SD19T6S1X-EV | 1.9TB 2.5 inch Enterprise Value 6G SATA SSD | SATA | 1.9 TB | |||||||
UCS-SD38T6S1X-EV | 3.8TB 2.5 inch Enterprise Value 6G SATA SSD | SATA | 3.8 TB | |||||||
UCS-SD76T6S1X-EV | 7.6TB 2.5 inch Enterprise Value 6G SATA SSD | SATA | 7.6 TB | |||||||
Self-Encrypted Drives (SED) [1] | ||||||||||
SAS | ||||||||||
UCS-HD600G15NK9 | 600 GB 12G SAS 15K RPM SFF HDD (SED) FIPS140-2 | SAS | 600 GB | |||||||
UCS-HD24T10NK9 | 2.4 TB 12G SAS 10K RPM SFF HDD (4K) (SED) FIPS140-2 | SAS | 2.4 TB | |||||||
UCS-HD18T10NK9 | 1.8 TB 12G SAS 10K RPM SFF HDD (4K format, SED) FIPS140-2 | SAS | 1.8 TB | |||||||
UCS-HD12T10NK9 | 1.2 TB 12G SAS 10K RPM SFF HDD (SED) FIPS140-2 | SAS | 1.2 TB | |||||||
UCS-SD800GBKNK9 | 800GB Enterprise Performance SAS SSD (3X DWPD, SED) FIPS140-2 | SAS | 800 GB | |||||||
UCS-SD960GBKNK9 | 960GB Enterprise Value SAS SSD (1X DWPD, SED) FIPS140-2 | SAS | 960 GB | |||||||
UCS-SD38TBKNK9 | 3.8TB Enterprise Value SAS SSD (1X DWPD, SED) FIPS140-2 | SAS | 3.8 TB | |||||||
UCS-SD16TBKNK9 | 1.6TB Enterprise performance SAS SSD (3X DWPD, SED) FIPS140-2 | SAS | 1.6 TB | |||||||
UCS-SD76TBKNK9 | 7.6TB Enterprise value SAS SSD (1X DWPD, SED-FIPS) FIPS140-2 | SAS | 7.6 TB | |||||||
SATA | ||||||||||
UCS-SD960GBM2NK9 | 960GB Enterprise value SATA SSD (1X, SED) Non FIPS | SATA | 960 GB | |||||||
UCS-SD38TBEM2NK9 | 3.8TB Enterprise value SATA SSD (1X, SED) Non FIPS | SATA | 3.8 TB | |||||||
UCS-SD76TBEM2NK9 | 7.6 TB Enterprise value SATA SSD (1X, SED) Non FIPS | SATA | 7.6 TB | |||||||
UCS-SD19TBEM2NK9 | 1.9TB Enterprise value SATA SSD (1X, SED) Non FIPS | SATA | 1.9 TB | |||||||
PCIe/NVMe LFF (2.5-inch) drives [2], [3] | ||||||||||
UCSC-NVMEHW-H800 | Cisco 2.5in U.2 800GB HGST SN200 NVMe High Perf. High Endurance | NVMe | 800 GB | |||||||
UCSC-NVMEHW-H6400 | Cisco 2.5in U.2 6.4 TB HGST SN200 NVMe High Perf. High Endurance | NVMe | 6.4 TB | |||||||
UCSC-NVMEHW-H7680 | Cisco 2.5in U.2 7.7 TB HGST SN200 NVMe High Perf. Value Endurance | NVMe | 7.7 TB | |||||||
UCSC-NVME2H-I2TBV | Cisco 2.5in U.2 2.0TB Intel P4510 NVMe High Perf. Value Endurance | NVMe | 2.0 TB | |||||||
UCSC-NVMEHW-I8000 | Cisco 2.5in U.2 8TB Intel P4510 NVMe High Perf. Value Endurance | NVMe | 8.0 TB | |||||||
UCSC-NVMEXPB-I375 | Cisco 2.5in 375 GB Intel Optane NVMe Extreme Performance SSD | NVMe | 375 GB | |||||||
UCSC-NVMEXP-I750 | Cisco 2.5in 750 GB Intel Optane NVMe Extreme Performance | NVMe | 750 GB | |||||||
UCSC-NVME2H-I1000 | Cisco 2.5in U.2 1.0 TB Intel P4510 NVMe High Perf. Value Endurance | NVMe | 1.0 TB | |||||||
UCSC-NVME2H-I1600 | Cisco 2.5in U.2 1.6TB Intel P4610 NVMe High Perf. High Endurance | NVMe | 1.6 TB | |||||||
UCSC-NVME2H-I3200 | Cisco 2.5in U.2 3.2TB Intel P4610 NVMe High Perf. High Endurance | NVMe | 3.2 TB | |||||||
UCSC-NVME2H-I4000 | Cisco 2.5in U.2 4.0TB Intel P4510 NVMe High Perf. Value Endurance | NVMe | 4.0 TB | |||||||
UCS-NVMEM6-W1600 | 1.6TB 2.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance | NVMe | 1.6 TB | |||||||
UCS-NVMEM6-W3200 | 3.2TB 2.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance | NVMe | 3.2 TB | |||||||
UCS-NVMEM6-W6400 | 6.4TB 2.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance | NVMe | 6.4 TB | |||||||
UCS-NVMEM6-W7680 | 7.6TB 2.5in U.2 WD SN840 NVMe Extreme Perf. Value Endurance | NVMe | 7.6 TB | |||||||
UCS-NVMEM6-W15300 | 15.3TB 2.5in U.2 WD SN840 NVMe Extreme Perf. Value Endurance | NVMe | 15.3 TB | |||||||
Footnote: | ||||||||||
[NOTE:] | Cisco uses solid state drives from a number of vendors. All solid state drives are subject to physical write limits and have varying maximum usage limitation specifications set by the manufacturer. Cisco will not replace any solid state drives that have exceeded any maximum usage specifications set by Cisco or the manufacturer, as determined solely by Cisco. | |||||||||
[1] | For all self-encrypting drives (SED), standalone Management (CIMC) and UCSM is supported for configuring and managing local keys. SED drives can be managed with local and remote key management (third-party key management). | |||||||||
[2] | If you choose one or two front-facing PCIe SSD or NVMe drives, drive slots 1 and 2 at the front of the chassis are reserved for these drives (see Images Above for drive slot numbering). | |||||||||
[3] | Except HGST, Intel and Western Digital (WD) NVMe drives can be mixed anywhere in a C240 M5. | |||||||||
[4] | When retrofitting rear facing drives with spare NVMe drives, you must order
the following along with the spare drives:
| |||||||||
[Caveats] | - | |||||||||
[1] | 2.5-inch SFF NVMe drives are connected directly to the CPU, not managed by the RAID controller. | |||||||||
[2] | You can mix HDDs and SSDs as long as you keep all HDDs in their own RAID volume and all SSDs in their own RAID volume. | |||||||||
[3] | You can mix SAS HDDs and SAS/SATA SSDs when using the Cisco 12G SAS RAID Controller or Cisco 12G SAS HBA. | |||||||||
[4] | If you order any SFF NVMe drives, you must also order two CPUs. | |||||||||
[5] | Except HGST, Intel and Western Digital (WD) NVMe drives can be mixed anywhere in a C240 M5. | |||||||||
[6] | SED drives can be mixed with the non-SED drives |
Intel® Virtual RAID on CPU (Intel® VROC)
Intel VROC: | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
[1] | The server supports Intel® Virtual RAID on CPU (Intel® VROC). VROC is an enterprise RAID solution used with Intel NVMe SSDs . The Intel® Volume Management Device (Intel® VMD) is a controller integrated into the CPU PCIe root complex. Intel® VMD NVMe SSDs are connected to the CPU, which allows the full performance potential of fast Intel® Optane™ SSDs to be realized. Intel® VROC, when implemented, replaces traditional hardware RAID host bus adapter (HBA) cards placed between the drives and the CPU. | |||||||||
Footnote: | ||||||||||
[1] | Intel® VROC is only supported with Intel drives | |||||||||
[2] | Intel® VROC enablement key factory pre-provisioned to BIOS - no additional licensing required. | |||||||||
VROC has the following features: | ||||||||||
[1] | Small Form Factor (SFF) drive support (only) | |||||||||
[2] | No battery backup (BBU) or external SuperCap needed | |||||||||
[3] | Software-based solution utilizing Intel SFF NVMe direct connected to Intel CPU | |||||||||
[4] | RAID 0/1/5/10 support | |||||||||
[5] | Windows, Linux, VMware OS support. | |||||||||
[6] | Host Tools- Windows GUI/CLI, Linux CLI. | |||||||||
[7] | UEFI Support- HII Utility, OBSE. | |||||||||
[8] | Intel VROC NVMe operates in UEFI mode only |
Available PCIe Option Cards
Product ID (PID) | PID Description | Location | Electrical Slot | Card Height | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Modular LAN on Motherboard (mLOM) | ||||||||||
UCSC-MLOM-C100-04 | Cisco UCS VIC 1497 Dual Port 40/100G QSFP28 CNA mLOM | mLOM | x 16 | - | ||||||
UCSC-MLOM-C25Q-04 | Cisco UCS VIC 1457 Quad Port 10/25G SFP28 mLOM | mLOM | x 16 | - | ||||||
UCSC-MLOM-C40Q-03 | Cisco UCS VIC 1387 Dual Port 40Gb QSFP+ CNA | mLOM | x 8 | - | ||||||
UCSC-MLOM-IRJ45 | Intel i350 Quad Port 1GBase-T NIC | mLOM | x 8 | - | ||||||
Virtual Interface Card (VICs) | ||||||||||
UCSC-PCIE-C100-04 | Cisco UCS VIC 1495 Dual Port 40/100G QSFP28 CNA | Riser 1 or 2 | x 16 | HHHL | ||||||
UCSC-PCIE-C40Q-03 | Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA | Riser 1 or 2 | x 16 | HHHL | ||||||
UCSC-PCIE-C25Q-04 | Cisco VIC 1455 VIC – Quad Port 10/25G SFP28 | Riser 1 or 2 | x 16 | HHHL | ||||||
Network Interface Cards (NICs) | ||||||||||
1 Gb NICs | ||||||||||
UCSC-PCIE-IRJ45 | Intel i350 Quad Port 1GBase-T NIC | Riser 1 or 2 | x 8 | - | ||||||
10 Gb NICs | ||||||||||
N2XX-AIPCI01 | Intel X520 Dual Port 10Gb SFP+ NIC | Riser 1 or 2 | x 8 | HHHL | ||||||
UCSC-PCIE-ID10GC | Intel X550-T2 Dual Port 10GBase-T NIC | Riser 1 or 2 | x 8 | HHHL | ||||||
UCSC-PCIE-ID10GF | Intel X710-DA2 Dual Port 10Gb SFP+ NIC | Riser 1 or 2 | x 8 | HHHL | ||||||
UCSC-PCIE-IQ10GF | Intel X710 Quad Port 10Gb SFP+ NIC | Riser 1 or 2 | x 8 | HHHL | ||||||
UCSC-PCIE-IQ10GC | Intel X710 Quad Port 10GBase-T NIC | Riser 1 or 2 | x 8 | HHHL | ||||||
25 Gb NICs | ||||||||||
UCSC-PCIE-QD25GF | Qlogic QL41212H Dual Port 25Gb NIC | Riser 1 or 2 | x 8 | HHHL | ||||||
UCSC-PCIE-ID25GF | Intel XXV710 Dual Port 25Gb SFP28 NIC | Riser 1 or 2 | x 8 | HHHL | ||||||
UCSC-P-M4D25GF | Mellanox MCX4121A-ACAT dual port 10/25G SFP28 NIC | Riser 1 or 2 | x 8 | HHHL | ||||||
UCSC-P-M5D25GF | Mellanox CX-5 EN MCX512A-ACAT 2x25/10GbE SFP NIC | Riser 1 or 2 | x 8 | HHHL | ||||||
40 Gb NICs | ||||||||||
UCSC-PCIE-QD40GF | Qlogic QL45412H Dual Port 40Gb NIC | Riser 1 or 2 | x 16 | HHHL | ||||||
UCSC-PCIE-ID40GF | Intel XL710 Dual Port 40Gb QSFP+ NIC | Riser 1 or 2 | x 8 | HHHL | ||||||
100 Gb NICs | ||||||||||
UCSC-PCIE-QS100GF | Qlogic QLE45611HLCU single port 100G NIC | Riser 1 or 2 | x 16 | HHHL | ||||||
UCSC-P-M5D100GF | Mellanox CX-5 MCX516A-CDAT 2x100GbE QSFP NIC | Riser 1 or 2 | x 16 | HHHL | ||||||
UCSC-P-M5S100GF | Mellanox CX-5 MCX515A-CCAT 1x100GbE QSFP NIC | Riser 1 or 2 | x 16 | HHHL | ||||||
PCIe - Accelerators/Smart NICs | ||||||||||
UCSC-P-IQAT8970 | Cisco-Intel 8970 QAT Offload PCIe Adapter | Riser 1 or 2 | x 16 | HHHL | ||||||
Host Bus Adapters (HBAs) | ||||||||||
UCSC-PCIE-QD16GF | Qlogic QLE2692 Dual Port 16G Fibre Channel HBA | Riser 1 or 2 | x 8 | HHHL | ||||||
UCSC-PCIE-BD16GF | Emulex LPe31002 Dual Port 16G Fibre Channel HBA | Riser 1 or 2 | x 8 | HHHL | ||||||
UCSC-PCIE-QD32GF | Qlogic QLE2742 Dual Port 32G Fibre Channel HBA | Riser 1 or 2 | x 8 | HHHL | ||||||
UCSC-PCIE-BS32GF | Emulex LPe32000-M2 Single Port 32G Fibre Channel HBA | Riser 1 or 2 | x 8 | HHHL | ||||||
UCSC-PCIE-BD32GF | Emulex LPe32002-M2 Dual Port 32G Fibre Channel HBA | Riser 1 or 2 | x 8 | HHHL | ||||||
UCS NVMe/PCIe Add in Cards [2] | ||||||||||
UCSC-NVME-H64003 | Cisco AIC 6.4TB HGST SN260 NVMe Extreme Performance High Endurance | Riser 1 or 2 | x 8 | HHHL | ||||||
UCSC-NVME-H38401 | Cisco AIC 3.8TB HGST SN260 NVMe Extreme Performance High Endurance | Riser 1 or 2 | x 8 | HHHL | ||||||
UCSC-NVME-H76801 | Cisco AIC 7.7TB HGST SN260 NVMe Extreme Performance Value Endurance [3] | Riser 1 or 2 | x 8 | HHHL | ||||||
Footnote: | ||||||||||
[1] | HHHL= Half Height Half Length | |||||||||
[2] | HHHL PCIe NVMe cards are not bootable. | |||||||||
[3] | QLogic/Emulex HBAs ship with FC optics installed in the HBA. | |||||||||
[Approved Configurations] | - | |||||||||
[1-CPU Systems] | You can select up to one of the PCIe option cards (slot 1) listed above | |||||||||
[2-CPU Systems] | You can select up to two of the PCIe option cards (slots 1 and 2) listed above | |||||||||
[Caveats] | - | |||||||||
[For 1-CPU systems:] |
| |||||||||
[For 2-CPU systems:] |
| |||||||||
[NOTE: ] | UCSM managed servers are discoverable only if a VIC is installed in slot 2 or a VIC is installed in the MLOM slot. If you install two GPUs, they must be located in slots 2 and 5. Therefore, if two GPUs are installed, UCSM managed servers are discoverable only if you install a VIC in the MLOM slot. |
Available Power Supply
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCSC-PSU1-770W | 770W AC power supply for C-Series Servers | |||||||||
UCSC-PSU1-1050W | 1050W AC power supply for C-Series servers | |||||||||
UCSC-PSUV2-1050DC | 1050W DC power supply for C-Series servers | |||||||||
UCSC-PSU1-1600W [1] | 1600W AC power supply for C-Series servers | |||||||||
UCSC-PSU1-1050ELV | Cisco UCS 1050W AC Power Supply for Rack Server Low Line | |||||||||
Footnote: | ||||||||||
[1] | PSU supported on C240/C240/HX | |||||||||
[2] | In a two power supply server, both power supplies must be identical. | |||||||||
[3] | Power supplies share a common electrical and physical design that allows for hot-plug and tool-less installation into M5 C-series servers. Each power supply is certified for high-efficiency operation and offer multiple power output options. This allows users to “right-size” based on server configuration, which improves power efficiency, lower overall energy costs and avoid stranded capacity in the data center. Use the power calculator at the following link to determine the needed power based on the options chosen (CPUs, drives, memory, and so on): |
Available Power Cords
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
R2XX-DMYMPWRCORD | No power cord (dummy PID to allow for a no power cord option) | |||||||||
NO-POWER-CORD | ECO friendly green option, no power cable will be shipped | |||||||||
CAB-48DC-40A-8AWG | C-Series -48VDC PSU Power Cord, 3.5M, 3 Wire, 8AWG, 40A | |||||||||
CAB-N5K6A-NA | Power Cord, 200/240V 6A, North America | |||||||||
CAB-AC-L620-C13 | AC Power Cord, NEMA L6-20 - C13, 2M/6.5ft | |||||||||
CAB-C13-CBN | CABASY,WIRE,JUMPER CORD, 27" L, C13/C14, 10A/250V | |||||||||
CAB-C13-C14-2M | CABASY,WIRE,JUMPER CORD, PWR, 2 Meter, C13/C14,10A/250V | |||||||||
CAB-C13-C14-AC | CORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M | |||||||||
CAB-250V-10A-AR | Power Cord, 250V, 10A, Argentina | |||||||||
CAB-9K10A-AU | Power Cord, 250VAC 10A 3112 Plug, Australia | |||||||||
CAB-250V-10A-CN | AC Power Cord - 250V, 10A - PRC | |||||||||
CAB-9K10A-EU | Power Cord, 250VAC 10A CEE 7/7 Plug, EU | |||||||||
CAB-250V-10A-ID | Power Cord, 250V, 10A, India | |||||||||
CAB-250V-10A-IS | Power Cord, SFS, 250V, 10A, Israel | |||||||||
CAB-9K10A-IT | Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy | |||||||||
CAB-9K10A-SW | Power Cord, 250VAC 10A MP232 Plug, Switzerland | |||||||||
CAB-9K10A-UK | Power Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK | |||||||||
CAB-9K12A-NA [1] | Power Cord, 125VAC 13A NEMA 5-15 Plug, North America | |||||||||
CAB-250V-10A-BR | Power Cord - 250V, 10A - Brazil | |||||||||
CAB-C13-C14-2M-JP | Power Cord C13-C14, 2M/6.5ft Japan PSE mark | |||||||||
CAB-9K10A-KOR [1] | Power Cord, 125VAC 13A KSC8305 Plug, Korea | |||||||||
CAB-ACTW | AC Power Cord (Taiwan), C13, EL 302, 2.3M | |||||||||
CAB-JPN-3PIN | Japan, 90-125VAC 12A NEMA 5-15 Plug, 2.4m | |||||||||
CAB-48DC-40A-INT | -48VDC PSU PWR Cord, 3.5M, 3 Wire, 8AWG, 40A (INT) | |||||||||
CAB-48DC-40A-AS | -48VDC PSU PWR Cord, 3.5M, 3Wire, 8AWG, 40A (AS/NZ) | |||||||||
CAB-C13-C14-IN | Power Cord Jumper,C13-C14 Connectors,1.4 Meter Length, India | |||||||||
CAB-C13-C14-3M-IN | Power Cord Jumper, C13-C14 Connectors, 3 Meter Length, India | |||||||||
Footnote: | ||||||||||
[1] | You can select a minimum of no power cords and a maximum of two. | |||||||||
[2] | If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server. | |||||||||
[Notes:] | This power cord is rated to 125V and only supported for PSU rated at 1050W or less |
Available Tool-less Rail Kit
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCSC-RAIL-NONE | No rail kit option | |||||||||
UCSC-RAILB-M4 | Ball Bearing Rail Kit for C220 and C240 M4/M5 Rack Servers |
Available Cable Management Arms (CMA)
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCSC-CMAF-M4 | Reversible Cable Management Arm (CMA) for C220 M4 and M5 rack servers | |||||||||
Footnote: | ||||||||||
[Notes] | For more information about the tool-less rail kit and cable management arm |
Order Security Devices (Optional)
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCSX-TPM2-001 | Trusted Platform Module 1.2 SPI-based for UCS Servers | |||||||||
UCSX-TPM2-002 | Trusted Platform Module 2.0 for UCS servers | |||||||||
UCSX-TPM2-002B | Trusted Platform Module 2.0 M5 UCS Servers (FIPS 140-2 Compliant) | |||||||||
UCSC-INT-SW01 | C220 M5 and C240 M5 Chassis Intrusion Switch | |||||||||
Footnote: | ||||||||||
[] | A Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy. Authentication (ensuring that the platform can prove that it is what it claims to be) and attestation (a process helping to prove that a platform is trustworthy and has not been breached) are necessary steps to ensure safer computing in all environments. | |||||||||
[] | A chassis intrusion switch gives a notification of any unauthorized mechanical access into the server. | |||||||||
[Notes] | The TPM module used in this system conforms to TPM v1.2 and 2.0, as defined by the Trusted Computing Group (TCG). It is also SPI-based. | |||||||||
[] | TPM installation is supported after-factory. However, a TPM installs with a one-way screw and cannot be replaced, upgraded, or moved to another server. If a server with a TPM is returned, the replacement server must be ordered with a new TPM. |
Cisco SD Card Module (Optional)
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCS-SD-128G | 128 GB SD Card for UCS Servers | |||||||||
UCS-SD-64G-S | 64 GB SD Card for UCS Servers | |||||||||
UCS-SD-32G-S | 32 GB SD Card for UCS Servers | |||||||||
Footnote: | ||||||||||
[1] | Order one or two matching SD cards. See Figure 5 on page 73 for the location of the mini storage module connector, which accommodates an SD module. Each SD module accommodates two SD cards. | |||||||||
[Caveats] | - | |||||||||
[1] | Install either one or two SD cards | |||||||||
[2] | Do not mix SD card sizes | |||||||||
[3] | You cannot mix SD cards with an internal M.2 SATA SSD |
M.2 SATA SSDs (Optional)
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCS-M2-240GB | 240 GB M.2 SATA SSD | |||||||||
UCS-M2-960GB | 960 GB M.2 SATA SSD | |||||||||
Footnote: | ||||||||||
[1] | Order one or two matching M.2 SATA SSDs (see Table 28) along with a mini storage carrier or a boot-optimized RAID controller | |||||||||
[NOTE: ] | It is recommended that M.2 SATA SSDs be used as boot-only devices. | |||||||||
[Caveats] | - | |||||||||
[] | You cannot mix M.2 SATA SSDs with SD cards. | |||||||||
[] | Order either one or two identical M.2 SATA SSDs for the mini-storage carrier or boot-optimized RAID controller. You cannot mix M.2 SATA SSD capacities. | |||||||||
[] | When ordering two M.2 SATA drives with embedded software RAID, the maximum number of internal SATA drives supported is six. To support greater than six internal drives, a Cisco 12G Raid Controller or a Cisco 12G SAS HBA must be ordered |
Mini Storage Carrier/Boot-Optimized RAID Controller
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCS-MSTOR-M2 | Mini Storage Carrier for M.2 SATA (holds up to 2 M.2 SATA SSDs) | |||||||||
UCS-M2-HWRAID | Cisco Boot optimized M.2 RAID controller (holds up to 2 M.2 SATA SSDs) | |||||||||
Footnote: | ||||||||||
[1] | Each mini | |||||||||
[NOTE: ] | - | |||||||||
[1] | The UCS-M2-HWRAID boot-optimized RAID controller supports RAID 1 and JBOD mode | |||||||||
[2] | The UCS-M2-HWRAID controller is available only with 240 GB and 960 GB M.2 SSDs. | |||||||||
[3] | (CIMC/UCSM) is supported for configuring of volumes and monitoring of the controller and installed SATA M.2 drives | |||||||||
[4] | The minimum version of Cisco IMC and Cisco UCS Manager that support this controller is 4.0(4b) and later. The name of the controller in the software is MSTOR-RAID | |||||||||
[5] | The SATA M.2 drives can boot in UEFI mode only. Legacy boot mode is not supported | |||||||||
[6] | Hot-plug replacement is not supported. The server must be powered off. | |||||||||
[7] | The boot-optimized RAID controller is not supported when the server is used as a compute node in HyperFlex configurations | |||||||||
[8] | Order either the Mini Storage carrier or the Boot-Optimized RAID controller | |||||||||
[9] | Choose the UCS-MSTOR-M2 mini storage carrier for controlling the M.2 SATA drives with no RAID control | |||||||||
[10] | Choose the UCS-M2-HWRAID Boot-Optimized RAID controller for hardware RAID across the two internal SATA M.2 drives. The Boot-Optimized RAID controller holds up to 2 matching M.2 SATA drives. | |||||||||
[11] | Order up to two matching M.2 SATA SSDs from | |||||||||
[NOTE: ] | The Boot-Optimized RAID controller supports VMWare, Windows and Linux Operating Systems | |||||||||
[Caveats] | - | |||||||||
[1] | You cannot mix M.2 SATA SSDs with SD cards. | |||||||||
[2] | Order either one or two identical M.2 SATA SSDs for the mini-storage carrier or boot-optimized RAID controller. You cannot mix M.2 SATA SSD capacities. | |||||||||
[3] | When ordering two M.2 SATA drives with embedded software RAID, the maximum number of internal SATA drives supported is six. To support greater than six internal drives, a Cisco 12G Raid Controller or a Cisco 12G SAS HBA must be ordered |
Internal Micro-SD Card Module (Optional)
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCS-MSD-32G | 32GB Micro-SD Card for UCS servers | |||||||||
Footnote: | ||||||||||
[1] | Order a 32 GB micro-SD card. The micro-SD card serves as a dedicated local resource for utilities such as a Host Upgrade Utility (HUU). Images can be pulled from a file share (NFS/CIFS) and uploaded to the card for future use. | |||||||||
[Caveats] | - | |||||||||
[1] | The micro-SD card mounts internally on riser 1. | |||||||||
[2] | The Flexutil user partition does not support OS installation. The user partition must be used for storage only. |
USB 3.0 Drive (Optional)
Product ID (PID) | PID Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
UCS-USBFLSHB-16GB | UCS Servers 16 GB Flash USB Drive | |||||||||
Footnote: | ||||||||||
[1] | Please view the images above to find the location of the USB connector. |
Spare Parts List
Marketing Part No. | Manufacturing Part No. | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Product ID (PID)PID Description | ||||||||||
KVM Cable | ||||||||||
N20-BKVM= KVM local IO cable for UCS servers console port | ||||||||||
CPU Accessories | ||||||||||
UCSC-HS-C240M5= Heat sink for UCS C240 M5 rack servers 150W CPUs & below | ||||||||||
UCSC-HS2-C240M5= Heat sink for UCS C240 M5 rack servers CPUs above 150W | ||||||||||
UCS-CPU-TIM= Single CPU thermal interface material syringe for M5 server HS seal [1] | ||||||||||
UCSX-HSCK=UCS Processor Heat Sink Cleaning Kit (when replacing a CPU) [2] | ||||||||||
UCS-CPUAT= CPU Assembly Tool for M5 Servers | ||||||||||
UCS-M5-CPU-CAR=UCS M5 CPU Carrier | ||||||||||
M.2 SATA SSD | ||||||||||
UCS-MSTOR-SD=SD module (holds up to 2 SD cards) | ||||||||||
UCS-MSTOR-M2= M.2 module (holds up to 2 M.2 SATA drives) | ||||||||||
UCS-M2-HWRAID=Cisco Boot optimized M.2 RAID controller (holds up to 2 M.2 SATA SSDs) | ||||||||||
Memory | ||||||||||
UCS-ML-X64G4RT-H=64 GB DDR4-2933-MHz LRDIMM/4Rx4 (8Gb) 1.2v | ||||||||||
UCS-MR-X64G2RT-H=64 GB DDR4-2933-MHz RDIMM/2Rx4 (16Gb) 1.2v | ||||||||||
DRIVES (Front Facing) | ||||||||||
HDDs | ||||||||||
HDDs (10K RPM) | ||||||||||
UCS-HY18TB10K4KN=1.8 TB 12G SAS 10K RPM LFF HDD (4K) | ||||||||||
UCS-HY12TB10K12N=1.2 TB 12G SAS 10K RPM LFF HDD | ||||||||||
HDDs (7.2K RPM) | ||||||||||
UCS-HD2T7KL12N=2 TB 12G SAS 7.2K RPM LFF HDD | ||||||||||
UCS-HD4T7KL12N=4 TB 12G SAS 7.2K RPM LFF HDD | ||||||||||
UCS-HD6T7KL4KN=6 TB 12G SAS 7.2K RPM LFF HDD (4K) | ||||||||||
UCS-HD8T7K4KAN=8 TB 12G SAS 7.2K RPM LFF HDD (4K) | ||||||||||
UCS-HD12T7KL4KN=12 TB 12G SAS 7.2K RPM LFF HDD (4K) | ||||||||||
UCS-HD14T7KL4KN=14 TB 12G SAS 7.2K RPM LFF HDD(4K) | ||||||||||
UCS-HD10T7KLEM10 TB 12G SAS 7.2K RPM LFF HDD (512e) | ||||||||||
UCS-HD8T7K6GAN=8 TB 6G SATA 7.2K RPM LFF HDD (512e) | ||||||||||
UCS-HD10T7K6GAN=10TB 6G SATA 7.2K RPM LFF HDD (512e) | ||||||||||
UCS-HD12T7KL6GN=12 TB 6G SATA 7.2K RPM LFF HDD (512e) | ||||||||||
SAS/SATA SSDs | ||||||||||
Enterprise Performance SSDs (High endurance, supports up to 10X or 3X DWPD (drive writes per day)) | ||||||||||
SAS SSDs | ||||||||||
UCS-HY800GK3X-EP=800GB 3.5in Enterprise Performance 12G SAS SSD(3X endurance) | ||||||||||
UCS-HY16TK3X-EP=1.6TB 3.5in Enterprise Performance 12G SAS SSD(3X endurance) | ||||||||||
SATA SSDs | ||||||||||
UCS-HY480G63X-EP=480GB 3.5in Enterprise performance 6G SATA SSD(3X endurance) (Intel S4600/S4610) | ||||||||||
UCS-HY960G63X-EP=960GB 3.5in Enterprise performance 6G SATA SSD(3X endurance) (Intel S4600/S4610) | ||||||||||
UCS-HY19T63X-EP=1.9TB 3.5in Enterprise performance 6G SATA SSD(3X endurance) (Intel S4600/S4610) | ||||||||||
Enterprise Value SATA SSDs (Low endurance, supports up to 1X DWPD (drive writes per day)) | ||||||||||
UCS-HY240G61X-EV=240 GB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863a/PM883) | ||||||||||
UCS-HY480G61X-EV=480 GB 2.5 inch Enterprise Value 6G SATA SSD (Intel 3520) | ||||||||||
UCS-HY960G61X-EV=960 GB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863a/PM883) | ||||||||||
UCS-HY19TM1X-EV=1.9TB 3.5 inch Enterprise Value 6G SATA SSD | ||||||||||
Self-Encrypted Drives (SED) | ||||||||||
HDDs | ||||||||||
UCS-HY600G15NK9=600 GB 12G SAS 15K RPM LFF HDD (SED) | ||||||||||
UCS-HD4T12GNK9=4 TB 7.2k RPM LFF HDD (SED) | ||||||||||
UCS-HD6T12GANK9=6 TB 7.2k RPM LFF HDD (4K format, SED) | ||||||||||
UCS-HD12T7KL4NK9=12 TB 7.2 K RPM LFF HDD (4K format SED) | ||||||||||
PCIe/NVMe LFF 2.5” drives | ||||||||||
UCSC-NVMEHY-H800=800 GB HGST SN200 NVMe High Perf. High Endurance (HGST) | ||||||||||
UCS-NVMEHY-W1600=1.6TB 3.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance | ||||||||||
UCS-NVMEHY-W3200=3.2TB 3.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance | ||||||||||
Drives (Rear Facing) | ||||||||||
HDDs | ||||||||||
HDDs (15K RPM) | ||||||||||
UCS-HD300G15K12N=300 GB 12G SAS 15K RPM SFF HDD | ||||||||||
UCS-HD600G15K12N=600 GB 12G SAS 15K RPM SFF HDD | ||||||||||
UCS-HD900G15K12N=900 GB 12G SAS 15K RPM SFF HDD | ||||||||||
HDDs (10K RPM) | ||||||||||
UCS-HD300G10K12N=300 GB 12G SAS 10K RPM SFF HDD | ||||||||||
UCS-HD600G10K12N=600 GB 12G SAS 10K RPM SFF HDD | ||||||||||
UCS-HD12TB10K12N=1.2 TB 12G SAS 10K RPM SFF HDD | ||||||||||
UCS-HD18TB10K4KN=1.8 TB 12G SAS 10K RPM SFF HDD (4K) | ||||||||||
UCS-HD24TB10K4KN=2.4 TB 12G SAS 10K RPM SFF HDD (4K) | ||||||||||
HDDs (7.2K RPM) | ||||||||||
UCS-HD1T7K12N=1 TB 12G SAS 7.2K RPM SFF HDD | ||||||||||
UCS-HD2T7K12N=2 TB 12G SAS 7.2K RPM SFF HDD | ||||||||||
UCS-HD1T7K6GAN=1 TB 6G SATA 7.2K RPM SFF HDD | ||||||||||
SAS/SATA SSDs | ||||||||||
Enterprise Performance SSDs (High endurance, supports up to 10X or 3X DWPD (drive writes per day)) | ||||||||||
UCS-SD960G63X-EP=960GB 2.5in Enterprise performance 6GSATA SSD(3X endurance) | ||||||||||
UCS-SD19T63X-EP=1.9TB 2.5in Enterprise performance 6GSATA SSD(3X endurance) | ||||||||||
UCS-SD480G63X-EP=480GB 2.5 inch Enterprise performance 6GSATA SSD(3X endurance) | ||||||||||
UCS-SD19TM3X-EP=1.9TB 2.5in Enterprise performance 6GSATA SSD(3X endurance | ||||||||||
UCS-SD480GM3X-EP=480GB 2.5in Enterprise Performance 6GSATA SSD(3X endurance) | ||||||||||
UCS-SD960GM3X-EP=960GB 2.5in Enterprise performance 6GSATA SSD(3X endurance) | ||||||||||
UCS-SD800GK3X-EP=800 GB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) | ||||||||||
UCS-SD16TK3X-EP=1.6 TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) | ||||||||||
UCS-SD32TK3X-EP=3.2 TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) | ||||||||||
UCS-SD800GS3X-EP=800GB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) | ||||||||||
UCS-SD16TS3X-EP=1.6TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) | ||||||||||
UCS-SD32TS3X-EP=3.2TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) | ||||||||||
Enterprise Value SSDs (Low endurance, supports up to 1X DWPD (drive writes per day)) | ||||||||||
UCS-SD480G6I1X-EV=480GB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500/S4150) | ||||||||||
UCS-SD960G6I1X-EV=960GB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500/S4150) | ||||||||||
UCS-SD38T6I1X-EV=3.8TB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500/S4150) | ||||||||||
UCS-SD120GM1X-EV=120 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | ||||||||||
UCS-SD240GM1X-EV=240 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | ||||||||||
UCS-SD480GM1X-EV=480 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | ||||||||||
UCS-SD960G61X-EV=960 GB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863A/PM883) | ||||||||||
UCS-SD960GM1X-EV=960 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | ||||||||||
UCS-SD16TM1X-EV=1.6 TB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | ||||||||||
UCS-SD19T61X-EV=1.9 TB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863A/PM883) | ||||||||||
UCS-SD19TM1X-EV=1.9 TB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | ||||||||||
UCS-SD38T61X-EV=3.8 TB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863A/PM883) | ||||||||||
UCS-SD38TM1X-EV=3.8 TB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | ||||||||||
UCS-SD76T61X-EV=7.6 TB 2.5 inch Enterprise Value 6G SATA SSD | ||||||||||
UCS-SD76TM1X-EV=7.6 TB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200) | ||||||||||
UCS-SD960G6S1X-EV=960GB 2.5 inch Enterprise Value 6G SATA SSD | ||||||||||
UCS-SD19T6S1X-EV=1.9TB 2.5 inch Enterprise Value 6G SATA SSD | ||||||||||
UCS-SD38T6S1X-EV=3.8TB 2.5 inch Enterprise Value 6G SATA SSD | ||||||||||
UCS-SD76T6S1X-EV=7.6TB 2.5 inch Enterprise Value 6G SATA SSD | ||||||||||
UCS-SD960GK1X-EV=960 GB 2.5 inch Enterprise Value 12G SAS SSD | ||||||||||
UCS-SD19TK1X-EV=1.9 TB 2.5 inch Enterprise Value 12G SAS SSD | ||||||||||
UCS-SD38TK1X-EV=3.8 TB 2.5 inch Enterprise Value 12G SAS SSD | ||||||||||
UCS-SD76TK1X-EV=7.6 TB 2.5 inch Enterprise Value 12G SAS SSD | ||||||||||
UCS-SD15TK1X-EV=15.3 TB 2.5 inch Enterprise Value 12G SAS SSD | ||||||||||
UCS-SD960GS1X-EV=960GB 2.5 inch Enterprise Value 12G SAS SSD | ||||||||||
UCS-SD19TS1X-EV=1.9TB 2.5 inch Enterprise Value 12G SAS SSD | ||||||||||
UCS-SD38TS1X-EV=3.8TB 2.5 inch Enterprise Value 12G SAS SSD | ||||||||||
Self-Encrypted Drives (SED) | ||||||||||
SAS | ||||||||||
UCS-HD600G15NK9=600 GB 12G SAS 15K RPM SFF HDD (SED) FIPS140-2 | ||||||||||
UCS-HD24T10NK9=2.4 TB 12G SAS 10K RPM SFF HDD (4K) (SED) FIPS140-2 | ||||||||||
UCS-HD18T10NK9=1.8 TB 12G SAS 10K RPM SFF HDD (4K format, SED) FIPS140-2 | ||||||||||
UCS-HD12T10NK9=1.2 TB 12G SAS 10K RPM SFF HDD (SED) FIPS140-2 | ||||||||||
UCS-SD800GBKNK9=800GB Enterprise Performance SAS SSD (3X DWPD, SED) FIPS140-2 | ||||||||||
UCS-SD960GBKNK9=960GB Enterprise Value SAS SSD (1X DWPD, SED) FIPS140-2 | ||||||||||
UCS-SD38TBKNK9=3.8TB Enterprise Value SAS SSD (1X DWPD, SED) FIPS140-2 | ||||||||||
UCS-SD16TBKNK9=1.6TB Enterprise performance SAS SSD (3X DWPD, SED) FIPS140-2 | ||||||||||
UCS-SD76TBKNK9=7.6TB Enterprise value SAS SSD (1 DWPD, SED-FIPS) FIPS140-2 | ||||||||||
SATA | ||||||||||
UCS-SD960GBM2NK9=960GB Enterprise value SATA SSD (1X, SED) Non FIPS | ||||||||||
UCS-SD38TBEM2NK9=3.8TB Enterprise value SATA SSD (1X, SED) Non FIPS | ||||||||||
UCS-SD76TBEM2NK9=7.6 TB Enterprise value SATA SSD (1X, SED) Non FIPS | ||||||||||
UCS-SD19TBEM2NK9=1.9TB Enterprise value SATA SSD (1X, SED) Non FIPS | ||||||||||
PCIe/NVMe LFF (2.5-inch) drives [2] | ||||||||||
UCSC-NVMEHW-H800=U.2 800 GB HGST SN200 NVMe High Perf. High Endurance (HGST) | ||||||||||
UCSC-NVMEHW-H6400=U.2 6.4 TB HGST SN200 NVMe High Perf. High Endurance (HGST) | ||||||||||
UCSC-NVMEHW-H7680=U.2 7.7 TB HGST SN200 NVMe High Perf. Value Endurance (HGST) | ||||||||||
UCSC-NVMEHW-I8000=Cisco 2.5" U.2 8TB Intel P4510 NVMe High Perf. Value Endurance | ||||||||||
UCSC-NVMEXPB-I375=375GB 2.5in Intel Optane NVMe Extreme Performance SSD | ||||||||||
UCSC-NVMEXP-I750=750GB 2.5in Intel Optane NVMe Extreme Perf | ||||||||||
UCSC-NVME2H-I1000=Cisco 2.5" U.2 1.0 TB Intel P4510 NVMe High Perf. Value Endu | ||||||||||
UCSC-NVME2H-I1600=Cisco 2.5in U.2 1.6TB Intel P4610 NVMe High Perf. High Endurance | ||||||||||
UCSC-NVME2H-I3200=Cisco 2.5in U.2 3.2TB Intel P4610 NVMe High Perf. High Endurance | ||||||||||
UCSC-NVME2H-I4000=Cisco 2.5in U.2 4.0TB Intel P4510 NVMe High Perf. Value Endurance | ||||||||||
UCSC-NVME2H-I2TBV=Cisco 2.5" U.2 2.0TB Intel P4510 NVMe High Perf. Value Endu | ||||||||||
UCS-NVMEM6-W1600=1.6TB 2.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance | ||||||||||
UCS-NVMEM6-W3200=3.2TB 2.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance | ||||||||||
UCS-NVMEM6-W6400=6.4TB 2.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance | ||||||||||
UCS-NVMEM6-W7680=7.6TB 2.5in U.2 WD SN840 NVMe Extreme Perf. Value Endurance | ||||||||||
UCS-NVMEM6-W15300=15.3TB 2.5in U.2 WD SN840 NVMe Extreme Perf. Value Endurance | ||||||||||
NVME cable | ||||||||||
CBL-NVME-C240LFF=C240 M5 Front NVMe cable (1) LFF | ||||||||||
UCSC-RNVME-240M5=C240 M5 Rear NVMe CBL(1) kit, Rear NVMe CBL, backplane SFF&LFF | ||||||||||
RAID Controllers | ||||||||||
UCSC-9400-8E=Cisco 9400-8E 12G SAS HBA for external JBOD attach | ||||||||||
UCSC-RSAS-240M5X=C240 Rear UCS-RAID-M5HD SAS cbl(1)kitinclfan,bkpln | ||||||||||
Modular LAN on Motherboard (mLOM) | ||||||||||
UCSC-MLOM-C100-04=Cisco UCS VIC 1497 Dual Port 40/100G QSFP28 CNA mLOM | ||||||||||
UCSC-MLOM-C25Q-04=Cisco UCS VIC 1457 Quad Port 10/25G SFP28 mLOM | ||||||||||
UCSC-MLOM-C40Q-03=Cisco UCS VIC 1387 Dual Port 40Gb QSFP+ CNA | ||||||||||
UCSC-MLOM-IRJ45=Intel i350 Quad Port 1GBase-T NIC | ||||||||||
UCSC-PCIE-C40Q-03= | Cisco UCS VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA | |||||||||
UCSC-PCIE-C25Q-04= | Cisco UCS VIC 1455 Quad Port 10/25G SFP28 CNA PCIE | |||||||||
Network Interface Cards (NICs) | ||||||||||
1 Gb NICs | ||||||||||
UCSC-PCIE-IRJ45= | Intel i350 Quad Port 1GBase-T NIC | |||||||||
10 Gb NICs | ||||||||||
N2XX-AIPCI01= | Intel X520 Dual Port 10Gb SFP+ NIC | |||||||||
UCSC-PCIE-ID10GC= | Intel X550-T2 Dual Port 10GBase-T NIC | |||||||||
UCSC-PCIE-ID10GF= | Intel X710-DA2 Dual Port 10Gb SFP+ NIC | |||||||||
UCSC-PCIE-IQ10GF= | Intel X710 Quad Port 10Gb SFP+ NIC | |||||||||
UCSC-PCIE-IQ10GC= | Intel X710 Quad Port 10GBase-T NIC | |||||||||
25 Gb NICs | ||||||||||
UCSC-PCIE-QD25GF= | Qlogic QL41212H Dual Port 25Gb NIC | |||||||||
UCSC-PCIE-ID25GF= | Intel XXV710 Dual Port 25Gb SFP28 NIC | |||||||||
UCSC-P-M4D25GF= | Mellanox MCX4121A-ACAT dual port 10/25G SFP28 NIC | |||||||||
40 Gb NICs | ||||||||||
UCSC-PCIE-QD40GF= | Qlogic QL45412H Dual Port 40Gb NIC | |||||||||
UCSC-PCIE-ID40GF= | Intel XL710 Dual Port 40Gb QSFP+ NIC | |||||||||
100 Gb NICs | ||||||||||
UCSC-PCIE-QS100GF= | Qlogic QLE45611HLCU single port 100G NIC | |||||||||
Host Bus Adapters (HBAs) | ||||||||||
UCSC-PCIE-QD16GF= | Qlogic QLE2692 Dual Port 16G Fibre Channel HBA | |||||||||
UCSC-PCIE-BD16GF= | Emulex LPe31002 Dual Port 16G Fibre Channel HBA | |||||||||
UCSC-PCIE-QD32GF= | Qlogic QLE2742 Dual Port 32G Fibre Channel HBA | |||||||||
UCSC-PCIE-BS32GF= | Emulex LPe32000-M2 Single Port 32G Fibre Channel HBA | |||||||||
UCSC-PCIE-BD32GF= | Emulex LPe32002-M2 Dual Port 32G Fibre Channel HBA | |||||||||
UCS NVMe/PCIe Add in Cards | ||||||||||
UCSC-NVME-H64003= | Cisco HHHL AIC 6.4TB HGST SN260 NVMe Extreme Performance High Endurance | |||||||||
UCSC-NVME-H38401= | Cisco HHHL AIC 3.8TB HGST SN260 NVMe Extreme Performance High Endurance | |||||||||
UCSC-NVME-H76801= | Cisco HHHL AIC 7.7TB HGST SN260 NVMeExtreme Performance Value Endurance | |||||||||
Other | ||||||||||
UCS-P40CBL-C240M5= | C240 M5 NVIDIA P40 Cable / M60 | |||||||||
UCS-P100CBL-240M5= | C240 M5 NVIDIA P100 / V100 / Cable | |||||||||
UCS-M10CBL-C240M5= | C240 M5 NVIDIA M10 Cable | |||||||||
CBL-SC-MR12GM5P= | Super Cap cable for UCSC-RAID-M5HD | |||||||||
UCSC-SCAP-M5= | Super Cap for Cisco 12G Modular RAID controller | |||||||||
PACK-QSFP-SFP= | Packaging for QSFP 40G and SFP 10G | |||||||||
SD Cards | ||||||||||
UCS-SD-32G-S= | 32 GB SD Card for UCS servers | |||||||||
UCS-SD-64G-S= | 64 GB SD Card for UCS servers | |||||||||
UCS-SD-128G= | 128GB SD Card for UCS servers | |||||||||
GPU PCIe Cards | ||||||||||
UCSC-GPU-P4= | NVIDIA P4 8GB | |||||||||
UCSC-GPU-T4-16= | NVIDIA T4 16GB | |||||||||
UCSC-GPU-M10= | NVIDIA M10 | |||||||||
UCSC-GPU-M60= | NVIDIA M60 | |||||||||
Power Supply | ||||||||||
UCSC-PSU1-770W= | 770W AC power supply for C-Series Servers | |||||||||
UCSC-PSU1-1050W= | 1050W AC power supply for C-Series servers | |||||||||
UCSC-PSUV2-1050DC= | 1050W DC power supply for C-Series servers | |||||||||
UCSC-PSU1-1600W= | 1600W AC power supply for C-Series servers | |||||||||
UCSC-PSU-M5BLK= | Power Supply Blanking Panel for M5 servers | |||||||||
UCSC-BBLKD-L2= | C-Series M5 LFF drive blanking panel | |||||||||
Power Cables | ||||||||||
CAB-48DC-40A-8AWG= | C-Series -48VDC PSU Power Cord, 3.5M, 3 Wire, 8AWG, 40A | |||||||||
CAB-N5K6A-NA= | Power Cord, 200/240V 6A, North America | |||||||||
CAB-AC-L620-C13= | AC Power Cord, NEMA L6-20 - C13, 2M/6.5ft | |||||||||
CAB-C13-CBN= | CABASY,WIRE,JUMPER CORD, 27" L, C13/C14, 10A/250V | |||||||||
CAB-C13-C14-2M= | CABASY,WIRE,JUMPER CORD, PWR, 2 Meter, C13/C14,10A/250V | |||||||||
CAB-C13-C14-AC= | CORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M | |||||||||
CAB-250V-10A-AR= | Power Cord, 250V, 10A, Argentina | |||||||||
CAB-9K10A-AU= | Power Cord, 250VAC 10A 3112 Plug, Australia | |||||||||
CAB-250V-10A-CN= | AC Power Cord - 250V, 10A - PRC | |||||||||
CAB-9K10A-EU= | Power Cord, 250VAC 10A CEE 7/7 Plug, EU | |||||||||
CAB-250V-10A-ID= | Power Cord, SFS, 250V, 10A, India | |||||||||
CAB-250V-10A-IS= | Power Cord, SFS, 250V, 10A, Israel | |||||||||
CAB-9K10A-IT= | Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy | |||||||||
CAB-9K10A-SW= | Power Cord, 250VAC 10A MP232 Plug, Switzerland | |||||||||
CAB-9K10A-UK= | Power Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK | |||||||||
CAB-9K12A-NA= | Power Cord, 125VAC 13A NEMA 5-15 Plug, North America | |||||||||
CAB-250V-10A-BR= | Power Cord - 250V, 10A - Brazil | |||||||||
CAB-C13-C14-2M-JP= | Power Cord C13-C14, 2M/6.5ft Japan PSE mark | |||||||||
CAB-9K10A-KOR= | Power Cord, 125VAC 13A KSC8305 Plug, Korea | |||||||||
CAB-ACTW= | AC Power Cord (Taiwan), C13, EL 302, 2.3M | |||||||||
CAB-JPN-3PIN= | Japan, 90-125VAC 12A NEMA 5-15 Plug, 2.4m | |||||||||
CAB-C13-C14-IN= | Power Cord Jumper,C13-C14 Connectors,1.4 Meter Length, India | |||||||||
CAB-C13-C14-3M-IN= | Power Cord Jumper, C13-C14 Connectors, 3 Meter Length, India | |||||||||
CMA | ||||||||||
UCSC-CMA-M5= | Reversible CMA for C240 M5 rack servers | |||||||||
USB Drive | ||||||||||
UCS-USBFLSHB-16GB= | UCS Servers 16 GB Flash USB Drive (optional) | |||||||||
TPM | ||||||||||
UCSX-TPM2-001= | Trusted Platform Module 1.2 for UCS Servers | |||||||||
UCSX-TPM2-002= | Trusted Platform Module 2.0 for UCS servers | |||||||||
UCSC-INT-SW01= | C220 M5 and C240 M5 Chassis Intrusion Switch | |||||||||
Bezel | ||||||||||
UCSC-BZL-C240M5= | C240 M5 Security Bezel |