Storage Limits
Max # of Drives (Total) | Max # of Internal Drives | Max # of MSATA Drives | Max # of NL-SAS Drives | Max # of SAS Drives | Max # of SATA Drives | Max # of SSD Drives | Max # of DS212C Shelves | Max # of DS2246 Shelves | Max # of DS224C Shelves | Max # of DS4243 Shelves | Max # of DS4246 Shelves | Max # of DS4486 Shelves | Max # of DS460C Shelves |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Supported Shelves/Drives | 1440 | N/A | 1440 | 1440 | 1440 | 1440 | 480 | 80 external | 60 external | 60 external | 60 external | 60 external | 30 external |
Capacity Limits
Marketing Max Raw Capacity - Node | HA Pair | Cluster | Effective Capacity - Node | HA Pair | Cluster |
---|---|---|---|---|---|
15000000 | 15000000 | N/A | 66577500 | 66577500 | N/A |
Core Cluster Limits
Max SVM's - NAS | Max LIF's - NAS | Max Connections - NAS | Max Flexible Volumes - NAS | Max Flexible Volumes with DPO - NAS | Max Lock Manager Locked Objects | Max Intercluster LIFs - Node | Min Root Aggregate (MiB) - Node | Min Root Volume (GiB) - Node | Max IPsec Policies | Max Auditing-Enabled SVMs - Cluster |
---|---|---|---|---|---|---|---|---|---|---|
Node:N/A HA Pair:N/A Cluster:1024 | Node:512 HA Pair:512 Cluster:3072 | Node:100000 HA Pair(Non-Scalable):100000 | Aggregate (Single data Agg. per Node):N/A Aggregate (Multiple data Agg. per Node):N/A Node:1000 HA Pair:2000 Cluster:15000 | Node:2500 HA Pair:5000 Cluster:12000 | Node:3000000 HA Pair:3000000 Cluster:12288000 | 8 | 1222656 | 962 | SVM:256 Cluster:1500 | 50 |
System Maximums and Limits
Max Nodes per Cluster (NAS / SAN) | Max FabricPool Size | Max Infinite Volume Data Constituent Size | Max FlexGroup Data Constituent Size | Min Root Volume Size | NetApp Volume Encryption |
---|---|---|---|---|---|
24 / 12 | 8400 TiB | Not Supported | 100 TiB | 962 GiB | Supported |
Processor
Processor Model | Processor Architecture | Processor Speed | Processor Count (Per Node) | Processor Count (Per Config) | Processor Cores (Per CPU) | Processor Cores (Per Node) | Processor Cores (Per Config) |
---|---|---|---|---|---|---|---|
64-bit 18-core 2.30 Ghz | 64 bit | 2.30 Ghz | 2 | 4 | 18 | 36 | 72 |
Memory
NVRAM (Per Node) | NVRAM (Per Config) | NVME (Per Node) | NVME (Per Config) | NVMEM (Per Node) | NVMEM (Per Config) | RAM (Per Node) | RAM (Per Config) |
---|---|---|---|---|---|---|---|
32 GB | 64 GB | N/A | N/A | N/A | N/A | 512 GB | 1024 GB |
Onboard Ports
Ethernet Ports | Fibre Channel | Ports UTA2 Ports | Expansion Slots | SAS Ports |
---|---|---|---|---|
- | - | - [1] | 20 x IO Module | - |
Physical Characteristics
Rack Units | Chassis Height | Chassis Width with Mounting Flanges | Chassis Width without Mounting Flanges | Chassis Depth with Cable Mgmt | Chassis Depth without Cable Mgmt | Chassis Weight |
---|---|---|---|---|---|---|
8 | N/A | 19.02" (48.3 cm) | 17.72" (45 cm) | 36.81" (93.5 cm) | 30.79" (78.2 cm) | See Weights by configuration |
System Clearance Dimensions
Front Clearance (Cooling) | Front Clearance (Maintenance) | Rear Clearance (Cooling) | Rear Clearance (Maintenance) |
---|---|---|---|
6.03" (15.3 cm) | 31.01" (78.7 cm) | 6.03" (15.3 cm) | 22.02" (55.9 cm) |
Environmental Requirements
Operating | Storage | Transit | Acoustic Noise | Input Power Voltage |
---|---|---|---|---|
Tempature: 41 to 113 deg F - 5 to 45 deg C Humidity: 8 to 90 % Altitude: Up to 10000.0 ft - Up to 3048.0 m | Tempature: -40 to 158 deg F - -40 to 70 deg C Humidity: 10 to 95 % Altitude: Up to 40000.0 ft - Up to 12192.0 m | Tempature: -40 to 158 deg F - -40 to 70 deg C Humidity: 10 to 95 % Altitude: Up to 39989.8 ft - Up to 12192 m | Sound Power: 7.4 bels Sound Pressure: 65 dBA | 100 to 120 200 to 240 |
Storage OS Requirements
Full OS Matrix | Recommended Version | Minimum OS | Maximum OS |
---|---|---|---|
View Full OS Report Below | 9.11.1 | 9.11.1RC1 | 9.11.1 |
Storage and Firmware
Full Firmware Matrix | BIOS | BMC |
---|---|---|
Full Firmware Report Below | N/A | N/A |
Product Standards Compliance
Full Compliance and Certificates Report | Cert. EMC/EMI | Cert. Safety | Cert. Safety/EMC/EMI | Cert. Safety/EMC/EMI/RoHS | Standard Safety/EMC/EMI | Standard Safety |
---|---|---|---|---|---|---|
Compliance and Certificates Report Below | AMCA, FCC, ICES, KC, Morocco, VCCI | BIS, CB, CSA, G_K_U-SoR, IRAM, NOM, NRCS, SONCAP, TBS | EAC, UKRSEPRO | BSMI, CE DoC, UKCA DoC | BS-EN-55024, BS-EN55035, CISPR 32, EN55022, EN55024, EN55032, EN55035, EN61000-3-2, EN61000-3-3, FCC Part 15 Class A, IC more... | ANSI/UL60950-1, ANSI/UL62368-1, BS-EN62368-1, CAN/CSA C22.2 No. 60950-1, CAN/CSA C22.2 No. 62368-1, CNS 14336, EN60825-1 more... |
NFS Cluster Limits
Max Export Policies - Cluster | Max Export Rules - Cluster | Max NFSv4 Access Control Entries | Max Client Objects | Max pNFS objects |
---|---|---|---|---|
24000 | 200000 | 1024 | Node:100000 HA Pair:100000 | Node:1024000 HA Pair:1024000 Cluster:12288000 |
WAFL Cluster Limits - All Maximums
Size 64-bit Aggregate (TiB) | Size 64-bit Volume (TiB) | File size 64-bit Volume (TiB) | Volume Snapshot Copies | Character length for Snapshot copy names | Hard links - File | inodes/files - Volume | Number of qtrees | Concurrent DataMotion for Volumes ops |
---|---|---|---|---|---|---|---|---|
800 | 100 | 16 | Volume:1023 Node:1023000 HA Pair:2046000 | 255 | 100000 | 2000000000 | Volume:4995 Node:100000 HA Pair:200000 Cluster:2400000 | Node:16 HA Pair:16 |
Quality of Service Cluster Limits
Max Policy Groups - Cluster | Max QoS User Workloads - Cluster |
---|---|
12000 | 40000 |
SAN Cluster Limits - All Maximums
# of storage virtual machines (SVMs) - SAN | # of flexible volumes - SAN | # of Flexible Vol with DPO - | # of LUNs | LUN mappings | LUN size (TiB) - LUN | FC queue depth available | # of SAN Hosts (ITNs) | # of LIFS - iSCSI | # of LIFS - FCP | # of igroups | # of Initiators | # of Portsets | # of iSCSI sessions |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Node:125 HA Pair:250 Cluster:1000 | Single data Aggregate:N/A Multiple data Aggregates:N/A Node:1000 HA Pair:2000 Cluster:12000 | Node:2500 HA Pair:5000 Cluster:12000 | Valume:1024 Node:12288 HA Pair:24576 Cluster:98304 | Node:12288 HA Pair:24576 Cluster:98304 | 16 | 2048 | Port:512 Node:8192 HA Pair:16384 Cluster:65536 | Port:32 Portset:32 Node:512 HA Pair:1024 Cluster:4096 | Port:32 Portset:32 Node:512 HA Pair:1024 Cluster:4096 | Node:4096 HA Pair:8192 Cluster:32768 | igroup:256 Node:4096 HA Pair:8192 Cluster:32768 | Node:4096 HA Pair:8192 Cluster:32768 | Node:8192 HA Pair:16384 Cluster:65536 |
CIFS Cluster Limits - All Maximums
# of Connected Shares | # of Regular Shares | # of Open files | # of Local users - Cluster | # of Local groups - Cluster | # of Local group members - Cluster |
---|---|---|---|---|---|
Node:1000000 HA Pair:1000000 | Node:N/A HA Pair:N/A Cluster:300000 | Connection:65536 Node:1500000 HA Pair:1500000 | 35000 | 320000 | 640000 |
Data Protection Cluster Limits - All Maximums
NDMP Sessions | Data Protection Mirrors | Load Sharing Mirrors - NAS SVM | Concurrent Snap Mirror / SnapVault transfers - Node | DP Mirror fan-out - Volume | LS Mirror fan-out - NAS SVM | # of Clusters that can be peered - Cluster | Volumes, SnapMirror relationship | SnapMirror Synchronous relationships | Flexible Volumes in SVM DR | SVM Disaster recovery - Cluster |
---|---|---|---|---|---|---|---|---|---|---|
Node:36 HA Pair (Non-Scalable):36 | Volume:1 Node:1000 HA Pair:2000 Cluster:15000 | 2 | 250 | 8 | 2 | 255 | FlexGroup:200 FlexGroup-Node:50 HA Pair:1000 Cluster:6000 | Volume:1 Node:40 HA Pair (Non-Scalable):40 | SVM:300 HA Pair:1000 | 128 |
NVMe/oF Cluster Limits - All Maximums
# of Storage virtual machines (SVMs), NVMe/oF - Cluster | # of Flexible volumes, NVMe/oF | # of Flexible volumes with DPO, NVMe/oF | # of Namespaces | # of Subsystems | # of Namespace Mappings | Namespace Size | I/O queue depth available - NVMe/FC - Queue | I/O queue count available - NVMe/FC - Controller | Hosts - Subsystem | LIFS, NVMe/oF | # of Controllers - NVMe/FC - Port | I/O Queue Count, NVMe/TCP - Controller | I/O Queue Depth - NVMe/TCP | Controllers, NVMe/TCP - Node |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
32 | Node:1000 HA Pair:2000 Cluster:12000 | Node:2500 HA Pair:5000 Cluster:12000 | Volume:1024 Node:12288 HA Pair:24576 Cluster:98304 | Node:512 Node:512 | Subsystem:1024 Node:12288 HA Pair:24576 Cluster:98304 | 16 | N/A | N/A | 64 | Port:16 SVM:8 Node:32 HA Pair:32 Cluster:32 | N/A | 2 | 128 | 1024 |
FlexCache Cluster Limits - All Maximums Cache
Degree of fan-out - Origin | Origin Volumes | Constituent Volumes | Volumes | Origin ConstituentVolumes |
---|---|---|---|---|
100 | Node:100 HA Pair:200 | Node:800 HA Pair:1600 | Node:100 HA Pair:200 | Node:800 HA Pair:1600 |
S3 Cluster Limits -
Max # of Buckets | Max # of Objects - Bucket | Max # of Users | Max Size of the Bucket (PB) - Vserver |
---|---|---|---|
Vserver:12000 Cluster:12000 | 400000000000 | Vserver:4000 Cluster:96000 | 20 |
Consistency Groups - All Maximums
Number of Consistency Groups - Cluster | Consistency Groups and Parents Consistency Groups - Cluster | Number of Parent Consistency Groups - Cluster | Child Consistency Groups in a Parent Consistency Groups - Parent Group | Flexible Volumes in a Consistency Group | Flexible Volumes for Child Consistency Groups under a Parent Group | Flexible Volumes in a Child Consistency Group |
---|---|---|---|---|---|---|
15000 | 15000 | 15000 | 5 | 80 | 80 | 80 |
Flex Array Specifications
Third Party Array Compatibility | Array LUN Absolute Min Raw Capacity | Array LUN Block Size | Default Array LUN RAID Group Size | Array LUN Max RAID Groups Per Aggregate | Max Array LUN Size | Max Array LUN Raid Group Size | Min Array LUN Size | Min Array LUN Root Vol Size | Min Array LUN RAID Group Size | Min Array LUN Aggregate Size | Array LUN neighborhood Visible Assigned Devices | Array LUN Recommended Min RAW Capacity | Spare Core Array LUN Min Size |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 73,440 GiB | 512 bytes | 8 | 150 | 15,675 GiB | 26 | 1.05 GiB | 1,744 GiB | 1 | 1,280 GiB | 0 | 122,400 GiB | 1,384 GiB |
Footnotes -
Notes ID | Notes Description |
---|---|
[1] | The onboard UTA2 ports can be configured as FC Target/Initiator or CNA (FCoE target/Ethernet). The UTA2 ports are based on a dual port ASIC and both ports on each ASIC must be set to the same mode (enforced by Data ONTAP). Install X6599A-R6 10GbE SFP+ modules or approved copper twinax cables when using in CNA (FCoE target/Ethernet) mode. Install X6596-R6 16Gb FC SFP+ module when using in FC Target/Initiator mode. |
Platform LED for FAS9000 Single Chassis HA Pair
LED Label | LED Name | Type | Status Indicator | Description | |||||
---|---|---|---|---|---|---|---|---|---|
3 | Chassis Attention LED, front | - | On Amber | The system halted or a fault occurred in the chassis. | |||||
- | - | - | Off | The system is operating normally. | |||||
4 | Chassis Power Config | - | On Green | At least one of the two PSUs is delivering power to the system. | |||||
- | - | - | Off | Neither PSU is delivering power to the system. | |||||
5 | Location LED on chassis front | - | On or flashing blue | The LED has been manually activated to aid in physically locating equipment | |||||
- | - | - | Off | The LED has not been manually activated to aid in physically locating equipment | |||||
Back View | |||||||||
LED Label | LED Name | Type | Status Indicator | Description | |||||
e0M/SP | Port Ethernet Config | Port Activity | Blinking amber | Traffic is flowing over the connection | |||||
- | - | - | Off | No traffic is flowing over the connection. | |||||
- | - | Port Link | Green | A connection is established on the port | |||||
- | - | - | Off | No connection is established on the port. |
Supported Shelves Drives for FAS9000 Single Chassis HA Pair
Part No. | Capacity | RPM | Drive Type | Encryption | Root-Data Partitioning | Root-Data-Data Partitioning | Storage Pool Partitioning | Max Drive Count | FlexArray |
---|---|---|---|---|---|---|---|---|---|
DS212C with IOM12 / IOM12B / IOM12 / IOM12B shelf modules | |||||||||
X302A-R5 | 1TB | 7.2K | SATA | No | Yes | No | No | 960 | Yes |
X306A-R5 | 2TB | 7.2K | SATA | No | Yes | No | No | 960 | Yes |
X308A-R5 | 3TB | 7.2K | SATA | No | Yes | No | No | 960 | Yes |
X315A-R6 [1] | 4TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 960 | Yes |
X317A [1] | 6TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 960 | Yes |
X318A-R6 | 8TB | 7.2K | NL-SAS | No | Yes | No | No | 960 | Yes |
X322A [1] | 10TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 960 | Yes |
X336A-R6 | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 960 | Yes |
X339A | 2TB | 7.2K | NL-SAS | No | Yes | No | No | 960 | Yes |
X380A | 10TB | 7.2K | NL-SAS | No | Yes | No | No | 960 | Yes |
X388A | 16TB | 7.2K | NL-SAS | No | Yes | No | No | 937 | Yes |
X477A-R6 | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 960 | Yes |
X488A-R5 | 900GB | 10K | SAS | No | Yes | No | No | 960 | Yes |
X489A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 960 | Yes |
X490A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 960 | Yes |
X363A-R6 | 3.84TB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X364A | 3.84TB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X366A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 480 | Yes |
X374A | 960GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X448A-R6 | 200GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X449A-R6 | 800GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X575A-R6 | 400GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X576A-R6 | 1.6TB | N/A | SSD | No | No | No | Yes | 480 | Yes |
DS224C with IOM12B / IOM12B / IOM12 / IOM12 shelf modules | |||||||||
X341A-R6 | 900GB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X342A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X343A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X416A-R5 [1] | 600GB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 1440 | Yes |
X417A-R6 [1] | 900GB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 1440 | Yes |
X421A-R5 | 450GB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X422A-R5 | 600GB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X423A-R5 | 900GB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X425A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X426A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X427A [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 1440 | Yes |
X427B-R6 [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 1440 | Yes |
X319A | 7.6TB | N/A | SSD | No | No | Yes | No | 480 | Yes |
X356A-R6 | 3.84TB | N/A | SSD | No | No | Yes | Yes | 480 | Yes |
X357A | 3.84TB | N/A | SSD | No | No | Yes | Yes | 480 | Yes |
X358A [1] | 3.84TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 480 | Yes |
X359A | 30.6TB | N/A | SSD | No | No | Yes | No | 480 | Yes |
X365A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 480 | Yes |
X371A | 960GB | N/A | SSD | No | No | Yes | Yes | 480 | Yes |
X386A [1] | 960GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 480 | Yes |
X438A-R6 | 400GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X439A-R6 | 1.6TB | N/A | SSD | No | No | Yes | Yes | 480 | Yes |
X440A-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 480 | Yes |
X440B-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 480 | Yes |
X446A-R6 | 200GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X446B-R6 | 200GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X447A-R6 | 800GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X670A | 15.3TB | N/A | SSD | No | No | Yes | No | 480 | Yes |
DS460C with IOM12B / IOM12 / IOM12B / IOM12 shelf modules | |||||||||
X375A | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 1440 | Yes |
X376A | 8TB | 7.2K | NL-SAS | No | Yes | No | No | 1440 | Yes |
X377A | 10TB | 7.2K | NL-SAS | No | Yes | No | No | 1440 | Yes |
X378A [1] | 10TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 1440 | Yes |
X379A | 960GB | N/A | SSD | No | No | No | Yes | 240 | Yes |
X387A | 16TB | 7.2K | NL-SAS | No | Yes | No | No | 937 | Yes |
DS2246 with IOM12 / IOM12 / IOM12B / IOM6 / IOM12B / IOM6 shelf modules | |||||||||
X341A-R6 | 900GB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X342A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X343A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X416A-R5 [1] | 600GB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 1440 | Yes |
X417A-R6 [1] | 900GB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 1440 | Yes |
X421A-R5 | 450GB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X422A-R5 | 600GB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X423A-R5 | 900GB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X425A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X426A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X427A [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 1440 | Yes |
X427B-R6 [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 1440 | Yes |
X356A-R6 | 3.84TB | N/A | SSD | No | No | Yes | Yes | 480 | Yes |
X357A | 3.84TB | N/A | SSD | No | No | Yes | Yes | 480 | Yes |
X358A [1] | 3.84TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 480 | Yes |
X365A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 480 | Yes |
X371A | 960GB | N/A | SSD | No | No | Yes | Yes | 480 | Yes |
X438A-R6 | 400GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X439A-R6 | 1.6TB | N/A | SSD | No | No | Yes | Yes | 480 | Yes |
X440A-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 480 | Yes |
X440B-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 480 | Yes |
X446A-R6 | 200GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X446B-R6 | 200GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X447A-R6 | 800GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
DS4246 with IOM6 / IOM12 / IOM12B / IOM12B / IOM6 / IOM12 shelf modules | |||||||||
X302A-R5 | 1TB | 7.2K | SATA | No | Yes | No | No | 1440 | Yes |
X306A-R5 | 2TB | 7.2K | SATA | No | Yes | No | No | 1440 | Yes |
X308A-R5 | 3TB | 7.2K | SATA | No | Yes | No | No | 1440 | Yes |
X309A-R6 [1] | 3TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 1440 | Yes |
X315A-R6 [1] | 4TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 1440 | Yes |
X316A-R6 | 6TB | 7.2K | NL-SAS | No | Yes | No | No | 1440 | Yes |
X317A [1] | 6TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 1440 | Yes |
X318A-R6 | 8TB | 7.2K | NL-SAS | No | Yes | No | No | 1440 | Yes |
X322A [1] | 10TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 1440 | Yes |
X336A-R6 | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 1440 | Yes |
X380A | 10TB | 7.2K | NL-SAS | No | Yes | No | No | 1440 | Yes |
X477A-R6 | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 1440 | Yes |
X488A-R5 | 900GB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X489A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X490A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 1440 | Yes |
X363A-R6 | 3.84TB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X366A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 480 | Yes |
X374A | 960GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X441A-R5 | 100GB | N/A | SSD | No | No | No | No | 480 | Yes |
X442A-R5 [3] | 100GB | N/A | SSD | No | No | No | No | 480 | Yes |
X448A-R6 | 200GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X449A-R6 | 800GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X575A-R6 | 400GB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X576A-R6 | 1.6TB | N/A | SSD | No | No | No | Yes | 480 | Yes |
X577A-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 480 | Yes |
DS4486 with IOM6 shelf modules | |||||||||
X381A | 10TB | 7.2K | MSATA | No | No | No | No | 1440 | Yes |
X478A-R5 [4] | 3TB | 7.2K | MSATA | No | No | No | No | 1440 | Yes |
X480A-R6 [4] | 4TB | 7.2K | MSATA | No | No | No | No | 1440 | Yes |
X481A-R6 | 6TB | 7.2K | MSATA | No | No | No | No | 1440 | Yes |
X483A-R6 | 8TB | 7.2K | MSATA | No | No | No | No | 1440 | Yes |
DS4243 [2] with IOM12 / IOM6 shelf modules | |||||||||
X302A-R5 | 1TB | 7.2K | SATA | No | No | No | No | 1440 | Yes |
X306A-R5 | 2TB | 7.2K | SATA | No | No | No | No | 1440 | Yes |
X308A-R5 | 3TB | 7.2K | SATA | No | No | No | No | 1440 | Yes |
Footnote: | |||||||||
[1] Mixing NSE drives or shelves with any other type of encrypting or non-encrypting drives or shelves across a stand-alone platform or high-availability (HA) pair is not supported. | |||||||||
[2] The DS4243 shelf requires an upgrade to IOM6 or IOM12 Expander Modules for support with FAS26x0, FAS8200, and FAS9000 platforms. | |||||||||
[3] This drive does not support the sanitization feature. | |||||||||
[4] SSD drives used for cache in a Flash Pool with DS4486 MSATA HDDs must be configured in a DS2246 shelf. |
Supported RAID Configurations - FAS9000 Single Chassis HA Pair
Drive Type | Drive Capacity Min | Drive Capacity Max | Minimum | Default | Maximum | ||||
---|---|---|---|---|---|---|---|---|---|
Data Aggregate | |||||||||
RAID4 | |||||||||
NL-SAS | 0 TB | 8 TB | 3 | 7 | 7 | ||||
SAS | 0 TB | 5.999 TB | 3 | 8 | 14 | ||||
SATA | 0 TB | 5.999 TB | 3 | 7 | 7 | ||||
SSD | 0 TB | 30.6 TB | 3 | 8 | 14 | ||||
RAID-DP | |||||||||
MSATA | 0 TB | 5.999 TB | 5 | 14 | 20 | ||||
MSATA | 6 TB | 8 TB | 5 | 14 | 14 | ||||
NL-SAS | 0 TB | 5.999 TB | 5 | 14 | 20 | ||||
NL-SAS | 6 TB | 10 TB | 5 | 14 | 14 | ||||
SAS | 0 TB | 5.999 TB | 5 | 16 | 28 | ||||
SATA | 0 TB | 5.999 TB | 5 | 14 | 20 | ||||
SSD | 0 TB | 30.6 TB | 5 | 24 | 28 | ||||
RAID-TEC | |||||||||
MSATA | 0 TB | 10 TB | 7 | 21 | 29 | ||||
NL-SAS | 0 TB | 16 TB | 7 | 21 | 29 | ||||
SAS | 0 TB | 8 TB | 7 | 24 | 29 | ||||
SATA | 0 TB | 8 TB | 7 | 21 | 29 | ||||
SSD | 0 TB | 30.6 TB | 7 | 25 | 29 | ||||
Root Aggregate | |||||||||
RAID4 | |||||||||
NL-SAS | 0 TB | 8 TB | 2 | - | 7 | ||||
SAS | 0 TB | 5.999 TB | 2 | - | 14 | ||||
SATA | 0 TB | 5.999 TB | 2 | - | 7 | ||||
SSD | 0 TB | 30.6 TB | 2 | - | 14 | ||||
RAID-DP | |||||||||
MSATA | 0 TB | 5.999 TB | 3[1] | - | 20 | ||||
MSATA | 6 TB | 8 TB | 3[1] | - | 14 | ||||
NL-SAS | 0 TB | 5.999 TB | 3[1] | - | 20 | ||||
NL-SAS | 6 TB | 16 TB | 3[1] | - | 14 | ||||
SAS | 0 TB | 5.999 TB | 3[1] | - | 28 | ||||
SATA | 0 TB | 5.999 TB | 3[1] | - | 20 | ||||
SSD | 0 TB | 30.6 TB | 3[1] | - | 28 | ||||
RAID-TEC | |||||||||
MSATA | 0 TB | 10 TB | 7 | - | 29 | ||||
NL-SAS | 0 TB | 16 TB | 7 | - | 29 | ||||
SAS | 0 TB | 8 TB | 7 | - | 29 | ||||
SATA | 0 TB | 8 TB | 7 | - | 29 | ||||
SSD | 0 TB | 30.6 TB | 7 | - | 29 | ||||
Footnote: | |||||||||
[1] The minimum number of disks in a RAID-DP group is three: at least one data disk, one regular parity disk, and one double-parity (dParity) disk. However, for non-root aggregates with only one RAID group, you must have at least 5 disks (three data disks and two parity disks). |
Supported Adapter Cards - FAS9000 Single Chassis HA Pair
Priority | Category | Bus Type | Mktg Part No. | Mfg Part No | Description | Plug Type | Optical Module Included? | Cables | Supported Protocol(s) | Min ONTAP | Max Qty [1] | Priority Slot Assignment | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | NVRAM | IO Module | X93140A | 111-03190 | NVRAM10 32GB | 111-03190 | NVRAM10 32GB | None | View | None | 9.1RC2, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | ||||||||
2 | Networking | IO Module | X91148A | 111-04761 | 2p 100GbE, QSFP28, gen3x16, RoCE | 111-04761 | 2p 100GbE, QSFP28, gen3x16, RoCE | QSFP28 | View | 9.8P11, 9.9.1P7, 9.10.1P1, 9.11.1RC1 | |||||||||
3 | Networking | IO Module | X91122A | 111-04764 | 2p 25GbE, SFP28, gen3x8, RoCE | 111-04764 | 2p 25GbE, SFP28, gen3x8, RoCE | SFP28 | View | 9.8P11, 9.9.1P7, 9.10.1P1, 9.11.1RC1 | |||||||||
4 | Networking | IO Module | X91440A [2] | 111-02590 | 2p 40GbE NIC Cu|Op | 111-02590 | 2p 40GbE NIC Cu|Op | QSFP | Ethernet 40Gb, Ethernet 40Gb w/4x10Gb breakout | View | Ethernet 40Gb, | 9.1RC2, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
5 | Block Access (Target) | IO Module | X91135A | 111-03789 | 4p 32Gb FC SFP+ Op | 111-03789 | 4p 32Gb FC SFP+ Op | SFP+ | Fibre Channel 8/16/32 Gb, NVMe/FC 16/32 Gb | View | Fibre Channel 8/16/32 Gb, | 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
6 | Block Access (Target) | IO Module | X91134A | 111-03431 | 2p 32Gb FC Op | 111-03431 | 2p 32Gb FC Op | SFP+ | Fibre Channel 8/16/32 Gb, NVMe/FC 16/32 Gb | View | Fibre Channel 8/16/32 Gb, | 9.1RC2, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
7 | Performance Acceleration | IO Module | X9170A | 108-00421 | NVMe SSD Module (1 TB) | 108-00421 | NVMe SSD Module (1 TB) | N/A | 9.1RC2, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | ||||||||||
8 | Performance Acceleration | IO Module | X9172A | 108-00423 | NVMe SSD Module (4 TB) | 108-00423 | NVMe SSD Module (4 TB) | N/A | 9.1RC2, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | ||||||||||
9 | Block Access | IO Module | X91143A | 111-02397 | 4p 16Gb|10Gb UTA2 Cu|Op | 111-02397 | 4p 16Gb|10Gb UTA2 Cu|Op | SFP+ | Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb | View | Ethernet 1/10 Gb, | 9.1RC2, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
10 | Networking | IO Module | X91143A | 111-02397 | 4p 16Gb|10Gb UTA2 Cu|Op | 111-02397 | 4p 16Gb|10Gb UTA2 Cu|Op | SFP+ | Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb | View | Ethernet 1/10 Gb, | 9.1RC2, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
11 | Networking | IO Module | X91120A | 111-02399 | 4p 10GBASE-T NIC | 111-02399 | 4p 10GBASE-T NIC | RJ45 | Ethernet 1/10 Gb | View | Ethernet 1/10 Gb | 9.1RC2, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
12 | Storage (Initiator) | IO Module | X91135A | 111-03789 | 4p 32Gb FC SFP+ Op | 111-03789 | 4p 32Gb FC SFP+ Op | SFP+ | Fibre Channel 8/16/32 Gb, NVMe/FC 16/32 Gb | View | Fibre Channel 8/16/32 Gb, | 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
13 | Storage | IO Module | X91143A | 111-02397 | 4p 16Gb|10Gb UTA2 Cu|Op | 111-02397 | 4p 16Gb|10Gb UTA2 Cu|Op | SFP+ | Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb | View | Ethernet 1/10 Gb, | 9.1RC2, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
14 | Storage | IO Module | X92071A [2] | 111-02396 | 4p 12Gb SAS Cu | 111-02396 | 4p 12Gb SAS Cu | MiniSAS HD | SAS 6/12 Gb | View | SAS 6/12 Gb | 9.1RC2, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
15 | Tape | IO Module | X92071A [2] | 111-02396 | 4p 12Gb SAS Cu | 111-02396 | 4p 12Gb SAS Cu | MiniSAS HD | SAS 6/12 Gb | View | SAS 6/12 Gb | 9.1RC2, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
16 | Tape (Initiator) | IO Module | X91135A [5] | 111-03789 | 4p 32Gb FC SFP+ Op | 111-03789 | 4p 32Gb FC SFP+ Op | SFP+ | Fibre Channel 8/16/32 Gb, NVMe/FC 16/32 Gb | View | Fibre Channel 8/16/32 Gb, | 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
17 | Tape | IO Module | X91143A [5] | 111-02397 | 4p 16Gb|10Gb UTA2 Cu|Op | 111-02397 | 4p 16Gb|10Gb UTA2 Cu|Op | SFP+ | Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb | View | Ethernet 1/10 Gb, | 9.1RC2, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
Footnote: | |||||||||||||||||||
[1] Values shown for max quantity are per controller. HA configurations will support 2x the values shown. | |||||||||||||||||||
[2] The base FAS9000 or AFF A700 configuration includes a 40GbE adapter in slot 4 (four) and a SAS HBA in slot 9 (nine). | |||||||||||||||||||
[3] The maximum number of all Ethernet ports on FAS9000 and AFF A700 is 32 per node and 64 per HA pair. When using the fan out cable to break down 40GbE ports into 10GbE ports, each resulting 10GbE port counts against the maximum Ethernet port limit | |||||||||||||||||||
[4] The maximum number of all Ethernet ports on FAS9000 and AFF A700 is 32 per node and 64 per HA pair | |||||||||||||||||||
[5] Connecting tape drives or tape libraries to FC or UTA2 ports requires the use of an FC switch. |
Supported Connections for FAS9000 Single Chassis HA Pair
Configuration Type | Port Configuration | Image | Cluster Ports per Node | Switch Ports per Node | |||||
---|---|---|---|---|---|---|---|---|---|
Cluster Interconnect | |||||||||
2-node Switchless Cluster | Default, Single NIC | View Image | 2 | None | |||||
2-node Switchless Cluster | Dual NIC, Recommended | View Image | 2 | None | |||||
Switched 10GbE Interconnect (breakout cabling) | Dual NIC, Recommended | View Image | 8 | 8 | |||||
Switched 10GbE Interconnect (breakout cabling) | Single NIC | View Image | 8 | 8 | |||||
Switched 40GbE Interconnect | Default, Single NIC | View Image | 2 | 2 | |||||
Switched 40GbE Interconnect | Dual NIC, Recommended | View Image | 2 | 2 |
Platform Mixing Rules - FAS9000 Single Chassis HA Pair
Platform Configuration Type | Maximum Nodes (NAS) [1] | Maximum Nodes (SAN) [1] | Min ONTAP Version for Platform Mixing | ||||||
---|---|---|---|---|---|---|---|---|---|
FAS - Current Configuration(s) | |||||||||
FAS2720A 10GBASE-T | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
FAS2720A UTA2 | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
FAS2750A 10GBASE-T | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
FAS2750A UTA2 | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
FAS500fA | 24 Nodes | 12 Nodes | 9.8RC1 | ||||||
FAS8300A Ethernet Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS8300A FC Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS8700A Ethernet Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS8700A FC Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS9000A | 24 Nodes | 12 Nodes | 9.1RC2 | ||||||
FAS9500A | 24 Nodes | 12 Nodes | 9.10.1P3 | ||||||
AllFlashFAS - Current Configuration(s) | |||||||||
AFF A250A | 24 Nodes | 12 Nodes | 9.8RC1 | ||||||
AFF A250A 100V | 24 Nodes | 12 Nodes | 9.8P4 | ||||||
AFF A400A Ethernet Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF A400A FC Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF A700A | 24 Nodes | 12 Nodes | 9.1RC2 | ||||||
AFF A800A | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
AFF A900A | 24 Nodes | 12 Nodes | 9.10.1 | ||||||
AFF C190A 10GBASE-T | 24 Nodes | 12 Nodes | 9.6RC2 | ||||||
AFF C190A UTA2 | 24 Nodes | 12 Nodes | 9.6RC2 | ||||||
FAS - Legacy EOA Configuration(s) | |||||||||
FAS8200A | 24 Nodes | 12 Nodes | 9.1RC2 | ||||||
AllFlashFAS - Legacy EOA Configuration(s) | |||||||||
AFF A220A 10GBASE-T | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
AFF A220A UTA2 | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
AFF A300A | 24 Nodes | 12 Nodes | 9.1RC2 | ||||||
AFF A320A | 24 Nodes | 12 Nodes | 9.6RC2 | ||||||
AFF A700s | 24 Nodes | 12 Nodes | 9.1 | ||||||
Footnote: | |||||||||
[1] Maximum number of nodes within a cluster is determined by platform which supports the fewest number of nodes |
Product Standard Compliance - FAS9000 Single Chassis HA Pair
Standard | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|
Certifications EMC/EMI | |||||||||
AMCA | Australia and New Zealand (EMC covered by ACMA DoC) | ||||||||
FCC | Federal Communications Commission (EMI Declaration of Conformity covering United States and Canada) | ||||||||
ICES | ICES | ||||||||
KC | Korea Communications Commission (EMC certificate for South Korea) | ||||||||
Morocco | Morocco Declaration of Conformity | ||||||||
VCCI | EMI Certificate for Japan | ||||||||
Certifications safety | |||||||||
BIS | Bureau of Indian Standard (Safety cert for India) | ||||||||
CB | Certificate Body issued safety certificate covering International | ||||||||
CSA | Canadian Standards Association issued Safety certificate covering North America | ||||||||
G_K_U-SoR | Safety certificate for Gabon, Kenya and Uganda | ||||||||
IRAM | Instituto Argentino de Normalización y Certificación (safety certificate for Argentina) | ||||||||
NOM | Norma Oficial Mexicana (Safety cert for Mexico) | ||||||||
NRCS | National Regulator for Compulsory Specifications (Safety cert for South Africa) | ||||||||
SONCAP | Standards Organisation of Nigeria Conformity Assessment Programme (Safety cert for Nigeria) | ||||||||
TBS | Tanzanian Bureau of Standards (Safety certificate for Tanzania) | ||||||||
Certifications Safety/EMC/EMI | |||||||||
EAC | Euro Asia Conformity (EMC and Safety Cert) covering (Russia, Kazakhstan, Belarus, Armenia, Kyrgyzstan Countries) | ||||||||
UKRSEPRO | EMC/Safety certificate for Ukraine | ||||||||
Certifications Safety/EMC/EMI/RoHS | |||||||||
BSMI | Certificate for Taiwan | ||||||||
CE DoC | European Union Declaration of Conformity | ||||||||
UKCA DoC | UK Declaration of Conformity | ||||||||
Standards EMC/EMI | |||||||||
BS-EN-55024 | EMC standard for Great Britain | ||||||||
BS-EN55035 | EMC standard for Great Britain | ||||||||
CISPR 32 | EMI | ||||||||
EN55022 | EMC Standard fo European Union | ||||||||
EN55024 | EMC Standard fo European Union | ||||||||
EN55032 | EMI Standard fo European Union | ||||||||
EN55035 | EMC Standard for European Union | ||||||||
EN61000-3-2 | EMC Standard for European Union | ||||||||
EN61000-3-3 | EMC Standard for European Union | ||||||||
FCC Part 15 Class A | EMI standard for United States | ||||||||
ICES-003 | EMI Standard for Canada | ||||||||
KS C 9832 | EMI Standard for South Korea | ||||||||
KS C 9835 | EMC Standard for South Korea | ||||||||
Standards Safety | |||||||||
ANSI/UL60950-1 | Safety standard for United States | ||||||||
ANSI/UL62368-1 | Safety standard for United States | ||||||||
BS-EN62368-1 | Safety standard for Great Britain | ||||||||
CAN/CSA C22.2 No. 60950-1 | Safety Standard for Canada | ||||||||
CAN/CSA C22.2 No. 62368-1 | Safety Standard for Canada | ||||||||
CNS 14336 | Safety Standard for Taiwan | ||||||||
EN60825-1 | Laser Safety standard for European Union | ||||||||
EN62368-1 | Safety standard for European Union | ||||||||
IEC 62368-1 | Safety Standard for International | ||||||||
IEC60950-1 | Safety standard for International | ||||||||
IS 13252(part 1) | Safety Standard for India |
Supported OS Version - FAS9000 Single Chassis HA Pair
OS Major Version | Supported OS Version | Supported Milestones | Recommend Version | ||||||
---|---|---|---|---|---|---|---|---|---|
Currently Supported OS | |||||||||
ONTAP 9.11.1 | 9.11.1, 9.11.1RC1 | End of Full Support: 31-Jul-2025 End of Limited Support: 31-Jul-2027 End of Self-Service Support: 31-Jul-2030 | 9.11.1 | ||||||
ONTAP 9.10.1 | 9.10.1P5, 9.10.1P7, 9.10.1P6, 9.10.1P4, 9.10.1P3, 9.10.1P2, 9.10.1P1, 9.10.1, 9.10.1RC1 | End of Full Support: 31-Jan-2025 End of Limited Support: 31-Jan-2027 End of Self-Service Support: 31-Jan-2030 | 9.10.1P7, 9.10.1P6 | ||||||
ONTAP 9.9.1 | 9.9.1P11, 9.9.1P10, 9.9.1P9, 9.9.1P8, 9.9.1P7, 9.9.1P6, 9.9.1P5, 9.9.1P4, 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 | End of Full Support: 30-Jun-2024 End of Limited Support: 30-Jun-2026 End of Self-Service Support: 30-Jun-2029 | 9.9.1P11, 9.9.1P10, 9.9.1P9 | ||||||
ONTAP 9.8 | 9.8P13, 9.8P12, 9.8P11, 9.8P10, 9.8P9, 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4, 9.8P3, 9.8P2, 9.8P1, 9.8, 9.8RC1 | End of Full Support: 31-Dec-2023 End of Limited Support: 31-Dec-2025 End of Self-Service Support: 31-Dec-2028 | 9.8P13, 9.8P12 | ||||||
ONTAP 9.7 | 9.7P19, 9.7P18, 9.7P17, 9.7P16, 9.7P15, 9.7P14, 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 | End of Full Support: 31-Jan-2023 End of Limited Support: 31-Jan-2025 End of Self-Service Support: 31-Jan-2028 | 9.7P19 | ||||||
EOS OS | |||||||||
ONTAP 9.7 | 9.7P19, 9.7P18, 9.7P17, 9.7P16, 9.7P15, 9.7P14, 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 | End of Full Support: 31-Jan-2023 End of Limited Support: 31-Jan-2025 End of Self-Service Support: 31-Jan-2028 | 9.7P19 | ||||||
ONTAP 9.6 | 9.6P18, 9.6P17, 9.6P16, 9.6P15, 9.6P14, 9.6P13, 9.6P12, 9.6P11, 9.6P10, 9.6P9, 9.6P8, 9.6P7, 9.6P6, 9.6P5, 9.6P4, 9.6P3, 9.6P2, 9.6P1, 9.6, 9.6RC2, 9.6RC1 | End of Full Support: 30-Jun-2022 End of Limited Support: 30-Jun-2024 End of Self-Service Support: 30-Jun-2027 | 9.6P18 | ||||||
ONTAP 9.5 | 9.5P19, 9.5P18, 9.5P17, 9.5P16, 9.5P15, 9.5P14, 9.5P13, 9.5P12, 9.5P11, 9.5P10, 9.5P9, 9.5P8, 9.5P7, 9.5P6, 9.5P5, 9.5P4, 9.5P3, 9.5P2, 9.5P1, 9.5, 9.5RC1 | End of Full Support: 31-Jan-2022 End of Limited Support: 31-Jan-2024 End of Self-Service Support: 31-Jan-2027 | 9.5P19 | ||||||
ONTAP 9.4 | 9.4P8, 9.4P7, 9.4P6, 9.4P5, 9.4P4, 9.4P3, 9.4P2, 9.4P1, 9.4, 9.4RC1 | End of Full Support: 30-Jun-2019 End of Limited Support: 30-Jun-2021 End of Self-Service Support: 30-Jun-2024 | 9.4P8 | ||||||
ONTAP 9.3 | 9.3P21, 9.3P20, 9.3P19, 9.3P18, 9.3P17, 9.3P16, 9.3P15, 9.3P14, 9.3P13, 9.3P12, 9.3P11, 9.3P10, 9.3P9, 9.3P8, 9.3P7, 9.3P6, 9.3P5, 9.3P4, 9.3P3, 9.3P2, 9.3P1, 9.3, 9.3RC1 | End of Full Support: 31-Jan-2021 End of Limited Support: 31-Jan-2023 End of Self-Service Support: 31-Jan-2026 | 9.3P21 | ||||||
ONTAP 9.2 | 9.2P4, 9.2P3, 9.2P2, 9.2P1, 9.2, 9.2RC1 | End of Full Support: 31-Jul-2018 End of Limited Support: 31-Jul-2020 End of Self-Service Support: 31-Jul-2023 | 9.2P4 | ||||||
Definitions: | |||||||||
[1]End of Full Support: The date marking the end of Full Support for a particular feature version of a NetApp system software and the beginning of Limited Support. Abbreviated as EOES. | |||||||||
[2]End of Limited Support: The date marking the end of Limited Support for a particular feature version of a product and transition to Self-Service Support. Abbreviated as EOVS. | |||||||||
[3]End of Self-Service Support: NetApp does not provide support for a version of a software product, but related documentation is still available on the NetApp Support Site. NetApp customers are expected to utilize documentation to resolve issues. |
Supported Power Cords for FAS9000 Single Chassis HA Pair
Marketing Part No. | End 1 / End 2 | Length | Description | |
---|---|---|---|---|
Non-Cabinet Power Cords | ||||
X-50617-00 | IEC60320-C20 / IEC60320-C13 | 2.00 m | Power Cords,In-Cabinet,2m,C20-C13,E-Series | |
X800B-R6 | CEE 7/7 (Schuko) / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Cont Europe/Korea,10A/250V | |
X800C-R6 | BS1363 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,UK/Ireland,10A/250V | |
X800D-R6 | JIS-C-8303 / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,Japan,15A/125V | |
X800E-R6 | NEMA 5-15P / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,North America,15A/125V | |
X800F-R6 | AS/NZS 3112 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Aus/NZ,10A/250V | |
X800G-R6 | SEV 1011 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Switzerland,10A/250V | |
X800H-R6 | IRAM 2073 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Argentina,10A/250V | |
X800I-R6 | GB2099 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,China,10A/250V | |
X800J-R6 | DHCR107-2-D1 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Demark,10A/250V | |
X800K-R6 | SANS 164-1 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,India/S.Africa,10A/250V | |
X800L-R6 | SI32 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Israel,10A/250V | |
X800M-R6 | CEI 23-16 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Italy,10A/250V | |
X800P-R6 | NEMA 6-15P / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,North America,15A/250V | |
X800T-R6 | CNS 10917-3 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Taiwan,BSMI,15A/125V | |
X800W-R6 | CNS10917/CNS690 / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,Taiwan,10A/250V | |
X800Y-R6 | JIS-C-830 / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,Japan,15A/250V | |
In-Cabinet Power Cords | ||||
X1558A-R6 | IEC60320-C14 / IEC60320-C13 | 1.20 m | Pwr Cord,In-Cabinet,48-In,C13-C14,10A/250V | |
X800-42U-35 | IEC60320-C14 / IEC60320-C13 | 0.89 m | Pwr Cord,In-Cabinet,C13-C14,35-inch | |
X800-42U-43 | IEC60320-C14 / IEC60320-C13 | 1.09 m | Pwr Cord,In-Cabinet,C13-C14,43-inch | |
X800-42U-64 | IEC60320-C14 / IEC60320-C13 | 1.63 m | Pwr Cord,In-Cabinet,C13-C14,64-inch | |
X800-42U-R6 | IEC60320-C14 / IEC60320-C13 | 0.68 m | Pwr Cord,In-Cabinet,27-In,C13-C14,10A/250V |
Onboard Ports Configuration: FAS9000 Single Chassis HA Pair
Port Address | Description | Supported Protocols | Port Icon | Port Type |
---|---|---|---|---|
e0M/SP | Management | Ethernet 10/100/1000 Mb | Wrench | RJ45 |
Serial Interface | Serial Console | RS-232 115200bps | Serial Interface | RJ45 |
Serial Interface | USB Serial Console | RS-232 115200bps | Serial Interface | USB 2.0 Micro-B |
Serial Interface | USB Serial Console (front chassis) | RS-232 115200bps | Serial Interface | USB 2.0 Micro-B |
USB | Storage Host Port | USB 2.0 | USB 2.0 | USB Type A |
Supported Platform Configurations - FAS9000 Single Chassis HA Pair
Platform Configuration | Description | Chassis Configuration | Chassis Count | Controller Count (per chassis) | IOXM Count (per chassis) | Rack Units (Per System) | Weight (Per Chassis) | Min ONTAP | |
---|---|---|---|---|---|---|---|---|---|
HA Pair | |||||||||
FAS9000A | FAS9000 Single Chassis HA Pair | CC | 1 | 2 | 0 | 8 | 214.47 lb (97.28 kg) | 9.1RC2, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
MetroCluster | |||||||||
FAS9000-2NBSMC | FAS9000 2-Node Stretch MetroCluster, Fiber Bridge | Cb-HA | 2 | 1 | 0 | 16 | 169.54 lb (76.9 kg) | 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS9000-2NDSMC | FAS9000 2-Node Stretch MetroCluster, Optical SAS | Cb-HA | 2 | 1 | 0 | 16 | 169.54 lb (76.9 kg) | 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS9000-2NFMC | FAS9000 2-Node Fabric MetroCluster | Cb-HA | 2 | 1 | 0 | 16 | 169.54 lb (76.9 kg) | 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS9000-4NFMC | FAS9000 4-Node Fabric MetroCluster | CC-CC | 2 | 2 | 0 | 16 | 214.47 lb (97.28 kg) | 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS9000-4NMCIP | FAS9000 4-Node MetroCluster IP | CC-CC | 2 | 2 | 0 | 16 | 214.47 lb (97.28 kg) | 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS9000-8NFMC | FAS9000 8-Node Fabric MetroCluster | 2x(CC-CC) | 4 | 2 | 0 | 32 | 214.47 lb (97.28 kg) | 9.1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS9000-8NMCIP | FAS9000 8-Node MetroCluster IP | 2x(CC-CC) | 4 | 2 | 0 | 32 | 214.47 lb (97.28 kg) | 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 |
Platform Memory Specifications - FAS9000 Single Chassis HA Pair
Part Number | Description | Mfg Part Number | Non-Volatile | Qty | Capacity (GB) | NVRAM/NVMEM Used Capacity (GB) | RAM Used Capacity (GB) |
---|---|---|---|---|---|---|---|
X93142A | DIMM,32GB | 107-00176 | no | 32 | 32 | - | 1024 |
X93141A | DIMM,16GB (NVS) | 107-00175 | yes | 4 | 16 | 64 | - |
Supported Rail Kit for FAS9000 Single Chassis HA Pair
Marketing Part No. | Manufacturing Part No. | Description | |
---|---|---|---|
NetApp System Cabinet Rail Kits | |||
X8783A-R6 | 111-01110 | Rail Kit III, NetApp Cabinet, R6 | |
X87880A | 111-03887 | Rail Kit 4,Cabinet | |
Third-Party Cabinet Rail Kits | |||
X-02659-00 | 113-00232 | Kit,4-Post,Square or Round-Hole, 24"-32" Rail | |
X90100A | 111-02860 | Kit,2-Post, Front-Mount | |
X90101A | 111-02861 | Kit,2-Post, Mid-Mount |
Field Replacement Unit Parts - FAS9000 Single Chassis HA Pair
Marketing Part No. | Manufacturing Part No. | Description | |
---|---|---|---|
Adapter Card | |||
X91120A [1] | 111-02399 | IO Module,4-PT 10GBASE-T | |
X91120A-C [1] | 111-02399 | IO Module,4-PT 10GBASE-T,-C | |
X91120A-N-C [1] | 111-02399 | IO Module,4-PT 10GBASE-T,-C | |
X91122A | 111-04764 | IO Module,2-Pt Bare Cage 25GbE RoCE SFP28 | |
X91122A-C | 111-04764 | IO Module,2-Pt Bare Cage 25GbE RoCE SFP28,-C | |
X91134A | 111-03431 | IO Module,2-Port FCP Target 32Gb PCIe w/SFP+ | |
X91134A-C | 111-03431 | IO Module,2-Port FCP Trgt 32Gb PCIe w/SFP+,-C | |
X91134A-N-C | 111-03431 | IO Module,2-Port FCP Trgt 32Gb PCIe w/SFP+,-C | |
X91135A [2] | 111-03789 | IO Module,4-pt 32Gb FC Trgt-Init, with SR SFP | |
X91135A-C [2] | 111-03789 | IO Module,4-pt 32Gb FC Trgt-Init, with SR SFP | |
X91135A-N-C [2] | 111-03789 | IO Module,4-pt 32Gb FC Trgt-Init, with SR SFP | |
X91143A [2] | 111-02397 | IO Module,4-PT CNA,10GbE,16GB FC | |
X91143A-C [2] | 111-02397 | IO Module,4-PT CNA,10GbE,16GB FC,-C | |
X91143A-N-C [2] | 111-02397 | IO Module,4-PT CNA,10GbE,16GB FC,-C | |
X91148A | 111-04761 | IO Module,2-Pt BareCage 100GbE RoCE QSFP28 | |
X91148A-C | 111-04761 | IO Module,2-Pt BareCage 100GbE RoCE QSFP28,-C | |
X91440A [3] [4] [5] [6] | 111-02590 | IO Module,2-PT 40GbE | |
X91440A-C [3] [4] [5] [6] | 111-02590 | IO Module,2-PT 40GbE,-C | |
X91440A-N-C [3] [4] [5] [6] | 111-02590 | IO Module,2-PT 40GbE,-C | |
X9170A | 108-00421 | NVMe SSD Module,1.0TB | |
X9170A-C | 108-00421 | NVMe SSD Module,1.0TB,-C | |
X9170A-N-C | 108-00421 | NVMe SSD Module,1.0TB,-C | |
X9172A | 108-00423 | Flash Cache,4.0TB,NVMe SSD Module | |
X9172A-C | 108-00423 | Flash Cache,4.0TB NVMe SSD Module,-C | |
X9172A-I-C | 108-00423 | Flash Cache,4.0TB Included,NVMe SSD Module,-C | |
X9172A-N-C | 108-00423 | Flash Cache,4.0TB NVMe SSD Module,-C | |
X92071A [4] | 111-02396 | IO Module,4-PT SAS,12Gb | |
X92071A-C [4] | 111-02396 | IO Module,4-PT SAS,12Gb,-C | |
X92071A-N-C [4] | 111-02396 | IO Module,4-PT SAS,12Gb,-C | |
X93140A | 111-03190 | NV Base Modules,32GB, 90XX | |
Battery | |||
X1847 | 271-01847 | Lithium System Battery CR2032 | |
X1847-R6 | 271-01847 | Lithium System Battery CR2032,R6 | |
Bezel | |||
X98000A | 111-03258 | Bezel,FAS90XX | |
Blank | |||
X93100A | 111-02414 | Blanking Panel,PCM,A700,90XX | |
X93101A | 111-02416 | Blanking Panel,IO Module,A700,90XX | |
X93102A | 111-02417 | Blanking Panel,NVS,A700,90XX | |
X93103A | 111-02418 | Blanking Panel,NVMe,A700,90XX | |
X93104A | 111-02424 | Blanking Panel,Power Supply,A700,90XX | |
X93105A | 111-02423 | Blanking Panel,Fan Assembly,A700,90XX | |
X93106A | 111-02769 | Blanking Panel,Battery Backup,A700,90XX | |
Boot Media | |||
X3320A | 501-01119 | DRIVE,SSD,128GB,mSATA | |
Cable Management Guide | |||
X98600A | 111-02878 | Cable Management Bracket,FAS90XX | |
Chassis | |||
X9000XA | 111-02392 | Chassis,no PSU, no PCM, no Fan, with MP | |
Data Cable | |||
X-QSFP-4SFP10G-CU3M | 112-00602 | Cable,Cisco,QSFP/4xSFP10G,CU Passive,3m | |
X-QSFP-4SFP10G-CU3M-C | 112-00602 | Cable,Cisco,QSFP/4xSFP10G,CU Passive,3m,-C | |
X-QSFP-4SFP10G-CU3M-N-C | 112-00602 | Cable,Cisco,QSFP/4xSFP10G,CU Passive,3m,-C | |
X-QSFP-4SFP10G-CU5M | 112-00603 | Cable,Cisco,QSFP/4xSFP10G,CU Passive,5m | |
X-QSFP-4SFP10G-CU5M-C | 112-00603 | Cable,Cisco,QSFP/4xSFP10G,CU Passive,5m,-C | |
X-QSFP-4SFP10G-CU5M-N-C | 112-00603 | Cable,Cisco,QSFP/4xSFP10G,CU Passive,5m,-C | |
X-QSFP-H40G-CU1M-R6 | 112-00307 | Cable,Cisco 40GB Twinax Copper QSFP+ 1M | |
X-QSFP-H40G-CU1M-R6-C | 112-00307 | Cable,Cisco 40GB Twinax Copper QSFP+ 1M,-C | |
X-QSFP-H40G-CU1M-R6-N-C | 112-00307 | Cable,Cisco 40GB Twinax Copper QSFP+ 1M,-C | |
X-QSFP-H40G-CU3M-R6 | 112-00604 | Cable,Cisco 40GB Twinax Copper QSFP+ 3M | |
X-QSFP-H40G-CU3M-R6-C | 112-00604 | Cable,Cisco 40GB Twinax Copper QSFP+ 3M,-C | |
X-QSFP-H40G-CU3M-R6-N-C | 112-00604 | Cable,Cisco 40GB Twinax Copper QSFP+ 3M,-C | |
X-QSFP-H40G-CU5M-R6 | 112-00604, 112-00605 | Cable,Cisco 40GB Twinax Copper QSFP+ 5M | |
X-QSFP-H40G-CU5M-R6-C | 112-00605 | Cable,Cisco 40GB Twinax Copper QSFP+ 5M,-C | |
X-QSFP-H40G-CU5M-R6-N-C | 112-00605 | Cable,Cisco 40GB Twinax Copper QSFP+ 5M,-C | |
X-SFP-H10GB-CU1M-R6 | 112-00210 | Cable,10GBase Copper SFP+ 1m | |
X-SFP-H10GB-CU1M-R6-C | 112-00210 | Cable,10GBase Copper SFP+ 1m,-C | |
X-SFP-H10GB-CU1M-R6-N-C | 112-00210 | Cable,10GBase Copper SFP+ 1m,-C | |
X-SFP-H10GB-CU3M-R6 | 112-00211 | Cable,10GBase Copper SFP+ 3m | |
X-SFP-H10GB-CU3M-R6-C | 112-00211 | Cable,10GBase Copper SFP+ 3m,-C | |
X-SFP-H10GB-CU3M-R6-N-C | 112-00211 | Cable,10GBase Copper SFP+ 3m,-C | |
X-SFP-H10GB-CU5M-R6 | 112-00212 | Cable,10GBase Copper SFP+ 5m | |
X-SFP-H10GB-CU5M-R6-C | 112-00212 | Cable,10GBase Copper SFP+ 5m,-C | |
X-SFP-H10GB-CU5M-R6-N-C | 112-00212 | Cable,10GBase Copper SFP+ 5m,-C | |
X6536-R6 | 112-00090 | Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op | |
X6536-R6-C | 112-00090 | Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op,-C | |
X6536-R6-N-C | 112-00090 | Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op,-C | |
X6537-R6 | 112-00091 | Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op | |
X6537-R6-C | 112-00091 | Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op,-C | |
X6537-R6-N-C | 112-00091 | Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op,-C | |
X65420 | 112-00508 | Cable,ASSY,USB 2.0 MICRO-B,USB-A,2M | |
X6546-R6 | 112-00074 | Cable,Cntlr-Shelf/Switch,30m,LC/SC,Op | |
X6547-R6 | 112-00073 | Cable,Cntlr-Shelf/Switch,5m,LC/SC,Op | |
X6553-R6 | 112-00188 | Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op | |
X6553-R6-C | 112-00188 | Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op,-C | |
X6553-R6-N-C | 112-00188 | Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op,-C | |
X6554-R6 | 112-00189 | Cable,Cntlr-Shelf/Switch,15m,LC/LC,Op | |
X6554-R6-C | 112-00189 | Cable,OPT,50u,2GHz/KM,MM,LC/LC,15M,-C,R6 | |
X6554-R6-N-C | 112-00189 | Cable,OPT,50u,2GHz/KM,MM,LC/LC,15M,-C,R6,-C | |
X6560-R6 | 112-00194 | Cable,Ethernet,0.5m RJ45 CAT6 | |
X6560-R6-C | 112-00194 | Cable,Ethernet,0.5m RJ45 CAT6,-C | |
X6560-R6-N-C | 112-00194 | Cable,Ethernet,0.5m RJ45 CAT6 | |
X6561-R6 | 112-00195 | Cable,Ethernet,2m RJ45 CAT6 | |
X6561-R6-C | 112-00195 | Cable,Ethernet,2m RJ45 CAT6,-C | |
X6561-R6-N-C | 112-00195 | Cable,Ethernet,2m RJ45 CAT6,-C | |
X6562-R6 | 112-00196 | Cable,Ethernet,5m RJ45 CAT6 | |
X6562-R6-C | 112-00196 | Cable,Ethernet,5m RJ45 CAT6,-C | |
X6562-R6-N-C | 112-00196 | Cable,Ethernet,5m RJ45 CAT6,-C | |
X6566B-05-N-C | 112-00297 | Cable,Direct Attach CU SFP+ 10G,0.5M,-C | |
X6566B-05-R6 | 112-00297 | Cable,Direct Attach CU SFP+ 10G,0.5M | |
X6566B-05-R6-C | 112-00297 | Cable,Direct Attach CU SFP+ 10G,0.5M,-C | |
X6566B-2-N-C | 112-00299 | Cable,Direct Attach CU SFP+ 10G,2M,-C | |
X6566B-2-R6 | 112-00299 | Cable,Direct Attach CU SFP+ 10G,2M | |
X6566B-2-R6-C | 112-00299 | Cable,Direct Attach CU SFP+ 10G,2M,-C | |
X6566B-3-N-C | 112-00300 | Cable,Direct Attach CU SFP+ 10G,3M,-C | |
X6566B-3-R6 | 112-00300 | Cable,Direct Attach CU SFP+ 10G,3M | |
X6566B-3-R6-C | 112-00300 | Cable,Direct Attach CU SFP+ 10G,3M,-C | |
X6566B-5-N-C | 112-00301 | Cable,Direct Attach CU SFP+ 10G,5M,-C | |
X6566B-5-R6 | 112-00301 | Cable,Direct Attach CU SFP+ 10G,5M | |
X6566B-5-R6-C | 112-00301 | Cable,Direct Attach CU SFP+ 10G,5M,-C | |
X6577-R6 | 112-00238 | Cable,Ethernet,30m RJ45 CAT6 | |
X6577-R6-C | 112-00238 | Cable,Ethernet,30m RJ45 CAT6,-C | |
X6577-R6-N-C | 112-00238 | Cable,Ethernet,30m RJ45 CAT6,-C | |
X6585-R6 | 112-00291 | Cable,Ethernet,3m RJ45 CAT6 | |
X6585-R6-C | 112-00291 | Cable,Ethernet,3m RJ45 CAT6,-C | |
X6585-R6-N-C | 112-00291 | Cable,Ethernet,3m RJ45 CAT6,-C | |
X6592-R6 | 112-00246 | Cable,Ethernet,10m RJ45 CAT6 | |
X6592-R6-N-C | 112-00246 | Cable,Ethernet,10m RJ45 CAT6,-C | |
X6593-R6 | 112-00247 | Cable,Ethernet,20m RJ45 CAT6 | |
X6593-R6-C | 112-00247 | Cable,Ethernet,20m RJ45 CAT6,-C | |
X6593-R6-N-C | 112-00247 | Cable,Ethernet,20m RJ45 CAT6,-C | |
X66020A-R6 | 112-00429 | Cable,Storage,MiniSAS HD,QSFP,12G,1m | |
X66020A-R6-C | 112-00429 | Cable,Storage,MiniSAS HD,QSFP,12G,1m,-C | |
X66021A-R6 | 112-00430 | Cable,Storage,MiniSAS HD,QSFP,12G,2m | |
X66021A-R6-C | 112-00430 | Cable,Storage,MiniSAS HD,QSFP,12G,2m,-C | |
X66022A-R6 | 112-00431 | Cable,Storage,MiniSAS HD,QSFP,12G,5m | |
X66022A-R6-C | 112-00431 | Cable,Storage,MiniSAS HD,QSFP,12G,5m,-C | |
X66030A | 112-00435 | Cable,12Gb,Mini SAS HD,0.5m | |
X66030A-C | 112-00435 | Cable,12Gb,Mini SAS HD,0.5m,-C | |
X66030A-K-N | 112-00435 | Cable,12Gb,Mini SAS HD,0.5m | |
X66030A-N | 112-00435 | Cable,12Gb,Mini SAS HD,0.5m | |
X66030A-N-C | 112-00435 | Cable,12Gb,Mini SAS HD,0.5m,-C | |
X66031A | 112-00436 | Cable,12Gb,Mini SAS HD,1m | |
X66031A-C | 112-00436 | Cable,12Gb,Mini SAS HD,1m,-C | |
X66031A-K-N | 112-00436 | Cable,12Gb,Mini SAS HD,1m | |
X66031A-N | 112-00436 | Cable,12Gb,Mini SAS HD,1m | |
X66031A-N-C | 112-00436 | Cable,12Gb,Mini SAS HD,1m,-C | |
X66032A | 112-00437 | Cable,12Gb,Mini SAS HD,2m | |
X66032A-C | 112-00437 | Cable,12Gb,Mini SAS HD,2m,-C | |
X66032A-K-N | 112-00437 | Cable,12Gb,Mini SAS HD,2m | |
X66032A-N | 112-00437 | Cable,12Gb,Mini SAS HD,2m | |
X66032A-N-C | 112-00437 | Cable,12Gb,Mini SAS HD,2m,-C | |
X66033A | 112-00438 | Cable,12Gb,Mini SAS HD,3m | |
X66033A-C | 112-00438 | Cable,12Gb,Mini SAS HD,3m,-C | |
X66033A-K-N | 112-00438 | Cable,12Gb,Mini SAS HD,3m | |
X66033A-N | 112-00438 | Cable,12Gb,Mini SAS HD,3m | |
X66033A-N-C | 112-00438 | Cable,12Gb,Mini SAS HD,3m,-C | |
X66034A | 112-00439 | Cable,12Gb,Mini SAS HD,5m | |
X66034A-C | 112-00439 | Cable,12Gb,Mini SAS HD,5m,-C | |
X66034A-K-N | 112-00439 | Cable,12Gb,Mini SAS HD,5m | |
X66034A-N | 112-00439 | Cable,12Gb,Mini SAS HD,5m | |
X66034A-N-C | 112-00439 | Cable,12Gb,Mini SAS HD,5m,-C | |
X66040A | 112-00449 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m | |
X66040A-C | 112-00449 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m,-C | |
X66040A-K-N | 112-00449 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m | |
X66040A-N | 112-00449 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m | |
X66040A-N-C | 112-00449 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m,-C | |
X66041A | 112-00450 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m | |
X66041A-C | 112-00450 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m,-C | |
X66041A-K-N | 112-00450 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m | |
X66041A-N | 112-00450 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m | |
X66041A-N-C | 112-00450 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m,-C | |
X66042A | 112-00451 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m | |
X66042A-C | 112-00451 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m,-C | |
X66042A-K-N | 112-00451 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m | |
X66042A-N | 112-00451 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m | |
X66042A-N-C | 112-00451 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m,-C | |
X66043A | 112-00452 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m | |
X66043A-C | 112-00452 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m,-C | |
X66043A-K-N | 112-00452 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m | |
X66043A-N | 112-00452 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m | |
X66043A-N-C | 112-00452 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m,-C | |
X66044A | 112-00453 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,15m | |
X66045A | 112-00454 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,30m | |
X66046A | 112-00455 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,50m | |
X66047A | 112-00456 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,5m | |
X66047A-C | 112-00456 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,5m,-C | |
X66047A-N-C | 112-00456 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,5m,-C | |
X66048A | 112-00457 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,30m | |
X66048A-C | 112-00457 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,30m,-C | |
X66048A-N-C | 112-00457 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,30m,-C | |
X66100-1 | 112-00542 | Cable,Direct Attach CU QSFP,40Gb,1m | |
X66100-1-C | 112-00542 | Cable,Direct Attach CU QSFP,40Gb,1m,-C | |
X66100-1-K-N | 112-00542 | Cable,Direct Attach CU QSFP,40Gb,1m | |
X66100-1-N | 112-00542 | Cable,Direct Attach CU QSFP,40Gb,1m | |
X66100-1-N-C | 112-00542 | Cable,Direct Attach CU QSFP,40Gb,1m,-C | |
X66100-3 | 112-00543 | Cable,Direct Attach CU QSFP,40Gb,3m | |
X66100-3-C | 112-00543 | Cable,Direct Attach CU QSFP,40Gb,3m,-C | |
X66100-3-K-N | 112-00543 | Cable,Direct Attach CU QSFP,40Gb,3m | |
X66100-3-N | 112-00543 | Cable,Direct Attach CU QSFP,40Gb,3m | |
X66100-3-N-C | 112-00543 | Cable,Direct Attach CU QSFP,40Gb,3m,-C | |
X66100-5 | 112-00544 | Cable,Direct Attach CU QSFP,40Gb,5m | |
X66100-5-C | 112-00544 | Cable,Direct Attach CU QSFP,40Gb,5m,-C | |
X66100-5-K-N | 112-00544 | Cable,Direct Attach CU QSFP,40Gb,5m | |
X66100-5-N | 112-00544 | Cable,Direct Attach CU QSFP,40Gb,5m | |
X66100-5-N-C | 112-00544 | Cable,Direct Attach CU QSFP,40Gb,5m,-C | |
X66120-3 | 112-00545 | Cable,Direct Attach CU 40G QSFP/4x10G SFP,3m | |
X66120-3-C | 112-00545 | Cable,Dir. Attach CU 40G QSFP/4x10G SFP,3m,-C | |
X66120-3-N-C | 112-00545 | Cable,Dir Attach CU 40G QSFP/4x10G SFP,3m,-C | |
X66120-5 | 112-00546 | Cable,Direct Attach CU 40G QSFP/4x10G SFP,5m | |
X66120-5-C | 112-00546 | Cable,Dir. Attach CU 40G QSFP/4x10G SFP,5m,-C | |
X66120-5-N-C | 112-00546 | Cable,Dir Attach CU 40G QSFP/4x10G SFP,5m,-C | |
X66200-15 | 112-00330 | Cable,Cntlr-Switch OM4,MPO/MPO,15m | |
X66200-15-C | 112-00330 | Cable,Cntlr-Switch OM4,MPO/MPO,15m,-C | |
X66200-15-N-C | 112-00330 | Cable,Cntlr-Switch OM4,MPO/MPO,15m,-C | |
X66200-2 | 112-00326 | Cable,Cntlr-Switch OM4,MPO/MPO,2m | |
X66200-2-C | 112-00326 | Cable,Cntlr-Switch OM4,MPO/MPO,2m,-C | |
X66200-2-N-C | 112-00326 | Cable,Cntlr-Switch OM4,MPO/MPO,2m,-C | |
X66200-30 | 112-00331 | Cable,Cntlr-Switch OM4,MPO/MPO,30m | |
X66200-30-C | 112-00331 | Cable,Cntlr-Switch OM4,MPO/MPO,30m,-C | |
X66200-30-N-C | 112-00331 | Cable,Cntlr-Switch OM4,MPO/MPO,30m,-C | |
X66200-5 | 112-00328 | Cable,Cntlr-Switch OM4,MPO/MPO,5m | |
X66200-5-C | 112-00328 | Cable,Cntlr-Switch OM4,MPO/MPO,5m,-C | |
X66200-5-N-C | 112-00328 | Cable,Cntlr-Switch OM4,MPO/MPO,5m,-C | |
X66205-30 | 112-00261 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m | |
X66205-30-C | 112-00261 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m,-C | |
X66205-30-N-C | 112-00261 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m,-C | |
X66205-5 | 112-00260 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m | |
X66205-5-C | 112-00260 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m,-C | |
X66205-5-N-C | 112-00260 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m,-C | |
X66211A-05 | 112-00595 | Cable,100GbE,QSFP28-QSFP28,Cu,0.5m | |
X66211A-05-C | 112-00595 | Cable,100GbE,QSFP28-QSFP28,Cu,0.5m,-C | |
X66211A-05-K-N | 112-00595 | Cable,100GbE,QSFP28-QSFP28,Cu,0.5m | |
X66211A-05-N | 112-00595 | Cable,100GbE,QSFP28-QSFP28,Cu,0.5m | |
X66211A-05-N-C | 112-00595 | Cable,100GbE,QSFP28-QSFP28,Cu,0.5m,-C | |
X66211A-1 | 112-00573 | Cable,100GbE,QSFP28-QSFP28,Cu,1m | |
X66211A-1-K-N | 112-00573 | Cable,100GbE,QSFP28-QSFP28,Cu,1m | |
X66211A-1-N | 112-00573 | Cable,100GbE,QSFP28-QSFP28,Cu,1m | |
X66211A-2 | 112-00574 | Cable,100GbE,QSFP28-QSFP28,Cu,2m | |
X66211A-2-K-N | 112-00574 | Cable,100GbE,QSFP28-QSFP28,Cu,2m | |
X66211A-2-N | 112-00574 | Cable,100GbE,QSFP28-QSFP28,Cu,2m | |
X66211A-5 | 112-00576 | Cable,100GbE,QSFP28-QSFP28,Cu,5m | |
X66211A-5-K-N | 112-00576 | Cable,100GbE,QSFP28-QSFP28,Cu,5m | |
X66211A-5-N | 112-00576 | Cable,100GbE,QSFP28-QSFP28,Cu,5m | |
X66211B-1-C | 112-00573 | Cable,100GbE,QSFP28-QSFP28,Cu,1m,-C | |
X66211B-1-N-C | 112-00573 | Cable,100GbE,QSFP28-QSFP28,Cu,1m,-C | |
X66211B-2-C | 112-00574 | Cable,100GbE,QSFP28-QSFP28,Cu,2m,-C | |
X66211B-2-N-C | 112-00574 | Cable,100GbE,QSFP28-QSFP28,Cu,2m,-C | |
X66211B-5-C | 112-00576 | Cable,100GbE,QSFP28-QSFP28,Cu,5m,-C | |
X66211B-5-N-C | 112-00576 | Cable,100GbE,QSFP28-QSFP28,Cu,5m,-C | |
X66220A-15 | 112-00586 | Cable,100GbE,QSFP28-QSFP28,AOC,15m | |
X66220A-15-N-C | 112-00586 | Cable,100GbE,QSFP28-QSFP28,AOC,15m,-C | |
X66220A-30 | 112-00589 | Cable,100GbE,QSFP28-QSFP28,AOC,30m | |
X66220A-30-N-C | 112-00589 | Cable,100GbE,QSFP28-QSFP28,AOC,30m,-C | |
X66240A-05 | 1111455002, 112-00639, NDCCGF-0006 | Cable,25GbE,SFP28-SFP28,Cu,0.5m | |
X66240A-05-N-C | 1111455002, 112-00639, NDCCGF-0006 | Cable,25GbE,SFP28-SFP28,Cu,0.5m,-C | |
X66240A-2 | 1111455000, 112-00598, NDCCGF-C102, NDCCGF-N102 | Cable,25GbE,SFP28-SFP28,Cu,2m | |
X66240A-2-N-C | 1111455000, 112-00598, NDCCGF-C102, NDCCGF-N102 | Cable,25GbE,SFP28-SFP28,Cu,2m,-C | |
X66240A-5 | 1111455001, 112-00600, NDCCGJ-C102, NDCCGJ-N105 | Cable,25GbE,SFP28-SFP28,Cu,5m | |
X66240A-5-N-C | 1111455001, 112-00600, NDCCGJ-C102, NDCCGJ-N105 | Cable,25GbE,SFP28-SFP28,Cu,5m,-C |
Supported Firmware Matrix - FAS9000 Single Chassis HA Pair
Major OS Version | OS Version | Firmeware | |||||||
---|---|---|---|---|---|---|---|---|---|
BIOS | |||||||||
ONTAP 9.11.1 | 9.11.1RC1 | 10.14* | |||||||
ONTAP 9.10.1 | 9.10.1P7, 9.10.1P5-P6 | 10.14* | |||||||
ONTAP 9.10.1 | 9.10.1P3-P4, 9.10.1P2, 9.10.1P1, 9.10.1, 9.10.1RC1 | 10.14, 10.12* | |||||||
ONTAP 9.9.1 | 9.9.1P11, 9.9.1P10 | 10.14* | |||||||
ONTAP 9.9.1 | 9.9.1P8-P9, 9.9.1P7, 9.9.1P4-P6 | 10.14, 10.12* | |||||||
ONTAP 9.9.1 | 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 | 10.14, 10.12, 10.11* | |||||||
ONTAP 9.8 | 9.8P13 | 10.14* | |||||||
ONTAP 9.8 | 9.8P11-P12, 9.8P10, 9.8P9 | 10.14, 10.12* | |||||||
ONTAP 9.8 | 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4 | 10.14, 10.12, 10.11* | |||||||
ONTAP 9.8 | 9.8P3, 9.8P2, 9.8P1, 9.8, 9.8RC1 | 10.14, 10.12, 10.11, 10.9* | |||||||
ONTAP 9.7 | 9.7P19, 9.7P17-P18 | 10.14, 10.12* | |||||||
ONTAP 9.7 | 9.7P16, 9.7P15, 9.7P14 | 10.14, 10.12, 10.11* | |||||||
ONTAP 9.7 | 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8 | 10.14, 10.12, 10.11, 10.9* | |||||||
ONTAP 9.7 | 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 | 10.14, 10.12, 10.11, 10.9, 10.7* | |||||||
ONTAP 9.6 | 9.6P18 | 10.14, 10.12* | |||||||
ONTAP 9.6 | 9.6P17, 9.6P16, 9.6P15 | 10.14, 10.12, 10.11* | |||||||
ONTAP 9.6 | 9.6P13-P14, 9.6P12 | 10.14, 10.12, 10.11, 10.9* | |||||||
ONTAP 9.6 | 9.6P10-P11 | 10.14, 10.12, 10.11, 10.9, 10.7* | |||||||
ONTAP 9.6 | 9.6P9, 9.6P7-P8, 9.6P5-P6, 9.6P4, 9.6P3 | 10.14, 10.12, 10.11, 10.9, 10.7, 10.5* | |||||||
ONTAP 9.6 | 9.6P2, 9.6, 9.6P1, 9.6RC2, 9.6RC1 | 10.14, 10.12, 10.11, 10.9, 10.7, 10.5* | |||||||
ONTAP 9.5 | 9.5P19 | 10.14, 10.12* | |||||||
ONTAP 9.5 | 9.5P18 | 10.14, 10.12, 10.11* | |||||||
ONTAP 9.5 | 9.5P17, 9.5P16, 9.5P15 | 10.14, 10.12, 10.11, 10.9* | |||||||
ONTAP 9.5 | 9.5P14 | 10.14, 10.12, 10.11, 10.9, 10.7* | |||||||
ONTAP 9.5 | 9.5P13, 9.5P12, 9.5P10-P11, 9.5P9, 9.5P8, 9.5P7, 9.5P6, 9.5P5, 9.5P4 | 10.14, 10.12, 10.11, 10.9, 10.7, 10.4* | |||||||
ONTAP 9.5 | 9.5P2-P3, 9.5P1, 9.5, 9.5RC1 | 10.14, 10.12, 10.11, 10.9, 10.7, 10.5, 10.4* | |||||||
ONTAP 9.4 | 9.4P8, 9.4P7, 9.4P6, 9.4P5, 9.4P4, 9.4P3, 9.4P2 | 10.14, 10.12, 10.11, 10.9, 10.7, 10.4, 10.3* | |||||||
ONTAP 9.4 | 9.4P1, 9.4, 9.4RC1 | 10.14, 10.12, 10.11, 10.9, 10.7, 10.5, 10.4, 10.3* | |||||||
ONTAP 9.3 | 9.3P21, 9.3P20 | 10.14, 10.12, 10.11, 10.9* | |||||||
ONTAP 9.3 | 9.3P18-P19 | 10.14, 10.12, 10.11, 10.9, 10.7* | |||||||
ONTAP 9.3 | 9.3P16-P17, 9.3P15, 9.3P11-P14, 9.3P10, 9.3P7-P9 | 10.14, 10.12, 10.11, 10.9, 10.5, 10.4, 10.3, 10.1* | |||||||
ONTAP 9.3 | 9.3P1-P6, 9.3, 9.3RC1 | 10.14, 10.12, 10.11, 10.9, 10.7, 10.5, 10.4, 10.3, 10.1* | |||||||
ONTAP 9.2 | 9.2P2-P4, 9.2P1 | 10.14, 10.12, 10.11, 10.9, 10.5, 10.4, 10.3, 10.1* | |||||||
ONTAP 9.2 | 9.2, 9.2RC1 | 10.14, 10.12, 10.11, 10.9, 10.7, 10.5, 10.4, 10.3, 10.1* | |||||||
ONTAP 9.1 | 9.1P17-P20, 9.1, 9.1RC2 | 10.14, 10.12, 10.11, 10.9, 10.7, 10.5, 10.4, 10.3, 10.1* | |||||||
ONTAP 9.1 | 9.1P13-P16, 9.1P10-P12, 9.1P9, 9.1P8, 9.1P3-P7, 9.1P1-P2 | 10.14, 10.12, 10.11, 10.9, 10.5, 10.4, 10.3, 10.1* | |||||||
Footnote: | |||||||||
[1]* Indicates that firmware is bundled with Storage OS Version |
Product Certificates - FAS9000 Single Chassis HA Pair
Certificate Name | Geo / Region / Country | Associated Products | |||||||
---|---|---|---|---|---|---|---|---|---|
Battery Pack safety reports | |||||||||
Lithium Battery Safety Doc-Section II/Section IB Shipments,Inventus Power Product Model#271-00046AWB | Global | Platforms : AFF A300, AFF A700, FAS8200, FAS9000 | |||||||
EMI and Safety certificates | |||||||||
Lithium Battery Safety Doc-Section II/Section IB Shipments,Inventus Power Product Model#271-00046AWB | Global | Platforms : AFF A300, AFF A700, FAS8200, FAS9000 | |||||||
Declaraion of Similarity NAF-1602 | Global | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 G-K-U-SoR | Gabon,Kenya,SaudiArabia,Uganda | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 60950-CB | CB - International | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 62368-CB | CB - International | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 ACMA | ACMA - Australia, New Zealand | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 (Jabil Mexico) BIS | BIS - India | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 (Jabil Singapore) BIS | BIS - India | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 BSMI | BSMI - Taiwan | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 CE DoC | CE - European Union DoC | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 CSA | CSA - United States, Canada | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 EAC | EAC - Armenia, Belarus, Kazakhstan, Kyrgyzstan, Russia | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 IRAM | IRAM - Argentina | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 KC | KC - South Korea | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 Morocco | Morocco | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 NOM | NOM - Mexico | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 NRCS | NRCS - South Africa (Safety) | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 SONCAP | SONCAP - Nigeria | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 TBS | TBS - Tanzania | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 UKRSep | UKRSepro - Ukraine | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 VCCI | VCCI - Japan | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
NAF-1602 UKCA DOC | UKCA -United Kingdom | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
PSU 80+ Platinum Certificates | |||||||||
NAF-1602 UKCA DOC | UKCA -United Kingdom | Platforms : AFF A700, AFF A900, ASA AFF A700, FAS9000, FAS9500 | |||||||
DPS-1600AB-4 A Energy Star Report | Global | PSU : X97600A | |||||||
Voluntary Product Accessibility Template | |||||||||
DPS-1600AB-4 A Energy Star Report | Global | PSU : X97600A |
Size, Weight, Acoustic, Power FAS9000 Single Chassis HA Pair
Associated Part No. | Configuration | Rack Units | Weight | Sound Power | Sound Pressure | Line Voltage Actual (Min to Max) | Amps Typical | Amps Worst | Watts Typical | Watts Worst | BTU / Hr Typical | BTU / Hr Worst |
---|---|---|---|---|---|---|---|---|---|---|---|---|
FAS9000 | ||||||||||||
FAS9000A | FAS9000 2 PCM 2xSAS, 6xUTA, 6x40G, 4x10Gb-T, 2x8TB | 8 | 214.5 lb (97.3 kg) | 7.4 Bels | 65 dBA | 100 (100 to 120) | 18.97 | 19.84 | 1859 | 1944 | 6345 | 6635 |
FAS9000A | FAS9000 2 PCM 2xSAS, 6xUTA, 6x40G, 4x10Gb-T, 2x8TB | 8 | 214.5 lb (97.3 kg) | 7.4 Bels | 65 dBA | 200 (200 to 240) | 9.3 | 9.73 | 1822 | 1906 | 6219 | 6505 |
FAS9000A | FAS9000 2 PCM 4xSAS, 2xUTA, 6x40G, 2x2TB | 8 | 198.0 lb (89.8 kg) | 7.4 Bels | 65 dBA | 100 (100 to 120) | 17.5 | 18.36 | 1715 | 1799 | 5854 | 6140 |
FAS9000A | FAS9000 2 PCM 4xSAS, 2xUTA, 6x40G, 2x2TB | 8 | 198.0 lb (89.8 kg) | 7.4 Bels | 65 dBA | 200 (200 to 240) | 8.58 | 9 | 1681 | 1764 | 5738 | 6021 |
FAS9000A | FAS9000 2 PCM 4xSAS, 2xUTA, 6x40G, 2x8TB | 8 | 198.0 lb (89.8 kg) | 7.4 Bels | 65 dBA | 100 (100 to 120) | 17.5 | 18.36 | 1715 | 1799 | 5854 | 6140 |
FAS9000A | FAS9000 2 PCM 4xSAS, 2xUTA, 6x40G, 2x8TB | 8 | 198.0 lb (89.8 kg) | 7.4 Bels | 65 dBA | 200 (200 to 240) | 8.58 | 9 | 1681 | 1764 | 5738 | 6021 |