Base Standard Capabilities
Feature | Technical Specifications | |
---|---|---|
Processor | Up to two 4th Generation Intel® Xeon Scalable processor, with up to 32 cores per processor and optional Intel® QuickAssist Technology | |
Memory | • 16 DDR5 DIMM slots, supports RDIMM 1 TB max, speeds up to 4800 MT/s • Supports registered ECC DDR5 DIMMs only | |
Storage controllers | • Internal PERC: fPERC H965i, fPERC H755N, fPERC H755, fPERC H355, fPERC HBA355i • Internal Boot: Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSD drives, or USB • External HBA (non-RAID): PERC HBA355e • Software RAID: S160 (for NVMe drives only) | |
Drive Bays | Front bays: • Up to 12 x 3.5-inch SAS/SATA HDD drives, max 180 TB • Up to 8 x 3.5-inch SAS/SATA HDD drives, max 120 TB • Up to 8 x 3.5-inch SAS/ SATA HDD + 8 x 2.5-inch NVMe SSD drives, max 240 TB • Up to 8 x 2.5-inch SAS/SATA HDD drives, max 120 TB • Up to 16 x 2.5-inch SAS/SATA HDD drives, max 240 TB • Up to 24 x 2.5-inch SAS/SATA HDD drives, max 360 TB | |
Power Supplies | • 2400 W Platinum 100—240 VAC or 2400 W 240 VDC, hot swap redundant • 1800 W Titanium 200—240 VAC or 1800 W 240 VDC, hot swap redundant • 1400 W Platinum 100—240 VAC or 1400 W 240 VDC, hot swap redundant • 1100 W Titanium 100—240 VAC or 1100 W 240 VDC, hot swap redundant • 1100 LVDC -48 — (-60) VDC, hot swap redundant • 800 W Platinum 100—240 VAC or 800 W 240 VDC, hot swap redundant • 700 W Titanium 200—240 VAC or 700 W 240 VDC, hot swap redundant • 600 W Platinum 100—240 VAC or 600 W 240 VDC, hot swap redundant | |
Cooling Options | Air cooling | |
Fans | • Up to eight Standard (STD) fans or High performance (HPR) fans | |
Dimensions | • Height — 464.0 mm (18.26 inches) (with feet) 508.8 mm (20.03 inches) (with caster wheels) 446.0 mm (17.60 inches) (without feet) • Width — 200.0 mm (7.87 inches) • Depth — 678.2 mm (26.70 inches) (with bezel) 660.6 mm (26 inches) (without bezel) | |
Form Factor | 4.5U tower server | |
Embedded Management | • iDRAC9 • iDRAC Direct • iDRAC RESTful API with Redfish • iDRAC Service Module • Quick Sync 2 wireless module | |
Bezel | Optional security bezel | |
OpenManage Software | • OpenManage Enterprise • OpenManage Power Manager plugin • OpenManage Service plugin • OpenManage Update Manager plugin • CloudIQ for PowerEdge plug in • OpenManage Enterprise Integration for VMware vCenter • OpenManage Integration for Microsoft System Center • OpenManage Integration with Windows Admin Center | |
Mobility | OpenManage Mobile | |
OpenManage Integrations | • BMC Truesight • Microsoft System Center • OpenManage Integration with ServiceNow • Red Hat Ansible Modules • Terraform Providers • VMware vCenter and vRealize Operations Manage | |
Security | • Cryptographically signed firmware • Data at Rest Encryption (SEDs with local or external key mgmt) • Secure Boot • Secure Erase • Secured Component Verification (Hardware integrity check) • Silicon Root of Trust • System Lockdown (requires iDRAC9 Enterprise or Datacenter) • TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ | |
Embedded NIC | 2 x 1GbE LOM on Planar | |
Network Options | 1 x OCP x8 card 3.0 Note: The system allows both LOM on planar and OCP card to be installed on the system. | |
GPU Options | Up to 2 x 300 W DW or 6 x 75 W SW | |
Ports | Front Ports • 1 x USB 2.0 • 1 x USB 3.0 • 1 x iDRAC Direct (Micro-AB USB) port | Rear Ports • 1 x USB 2.0 • 1 x USB 3.0 • 1 x Serial port (optional) • 1 x Dedicated iDRAC (RJ45) port • 1 x VGA port • 2 x Ethernet ports |
Internal Ports • 1 x USB 3.0 (optional) | ||
PCIe | Up to six PCIe slots: • Slot 1: x16 Gen5 Full height, Full length • Slot 2: x16 Gen5 Full height, Full length • Slot 3: x16 Gen4 Full height, Half length • Slot 4: x16 Gen4 Full height, Half length • Slot 5: x16 (x8 lanes) Gen4 Full height, Half length • Slot 6: x16 Gen4 Full height, Half length | |
Operating System and Hypervisors | • Canonical Ubuntu Server LTS • Microsoft Windows Server with Hyper-V • Red Hat Enterprise Linux • SUSE Linux Enterprise Server • VMware ESXi |
Compare Servers
Feature | PowerEdge T560 | PowerEdge T550 | ||
---|---|---|---|---|
Processors | Up to two 4th Generation Intel ® Xeon Scalable processors with up to 32 cores per processor | Up to two 3rd Generation Intel Xeon Scalable processors with up to 32 cores | ||
Memory | DIMM Speed • Up to 4800 MT/s Memory Type • RDIMM Memory module slots • 16 DDR5 DIMM slots • Supports registered ECC DDR5 DIMM slots only Maximum RAM • RDIMM 1TB | DIMM Speed • Up to 3200 MT/s Memory Type • RDIMM Memory module slots • 16 DDR4 DIMM slots • Supports registered ECC DDR4 DIMM slots only Maximum RAM • RDIMM 1TB | ||
Storage Controllers | • Internal PERC: fPERC HBA355i, fPERC H755, fPERC
H755N, fPERC H355, fPERC H965i • Internal Boot: Boot Optimized Storage Subsystem (BOSS- N1): HWRAID 2 x M.2 NVMe SSDs drives, or USB • External HBA (non-RAID): PERC HBA355e • Software RAID: S160 (NVMe only) | • Internal controllers: PERC H345,
PERC H755, H755N, HBA355i • Internal Boot: Internal Dual SD Module or Boot Optimized Storage Subsystem (BOSS-S2): HWRAID 2 x M.2 SSDs or USB • External Controller (RAID): PERC H840 • External HBAs (non-RAID): HBA355e • Software RAID: S150 | ||
Drive Bays | Front bays: • Up to 12 x 3.5-inch SAS/SATA HDD drives, max 180 TB • Up to 8 x 3.5-inch SAS/SATA HDD drives, max 120 TB • Up to 8 x 3.5-inch SAS/ SATA HDD + 8 x 2.5-inch NVMe SSD drives, max 240 TB • Up to 8 x 2.5-inch SAS/SATA HDD drives, max 120 TB • Up to 16 x 2.5-inch SAS/SATA HDD drives, max 240 TB • Up to 24 x 2.5-inch SAS/SATA HDD drives, max 360 TB | Front bays: • Up to 8 x 2.5-inch SAS/SATA (hard drive) max 120 TB • 16 x 2.5-inch SAS/SATA (HDD) max 240 TB • 24 x 2.5-inch SAS/SATA (HDD)max 360 TB • 8 x 3.5-inch SAS/SATA (HDD/SAS) max 120 TB • 8 x 3.5-inch SAS/SATA (HDD) + 8 x 2.5-inch NVMe (SSD) max 240 TB | ||
Power Supplies | • 600 W Platinum 100-240 VAC or 600 W 240 HVDC, hot
swap redundant • 800 W Platinum 100-240 VAC or 800 W 240 HVDC, hot swap redundant • 1100 LVDC -48 - (-60) VDC, hot swap redundant • 1400 W Platinum 100-240 VAC or 1400 W 240 HVDC, hot swap redundant • 2400 W Platinum 100-240 VAC or 2400 W 240 HVDC, hot swap redundant • 700 W Titanium 200-240 VAC or 700 W 240 HVDC, hot swap redundant • 1100 W Titanium 100-240 VAC or 1100 W 240 HVDC, hot swap redundant • 1800 W Titanium 200-240 VAC or 1800 W 240 HVDC, hot swap redundant | • 600 W Platinum AC/100 - 240 V • 600 W DC/240 V • 800 W Platinum AC/100 - 240 V • 800 W DC/240 V • 1100 W Titanium AC/100 - 240 V • 1100 W DC/240 V • 1100 W DC/-48 V • 1400 W Platinum AC/100 - 240 V • 1400 W DC/240 V • 2400 W Platinum AC/100 - 240 V • 2400 W DC/240 V | ||
Cooling Options | Air cooling | Air cooling | ||
Fans | Standard (STD) fans or High performance (HPR) fans | Standard (STD) fans /High performance (HPR) silver fans | ||
Up to eight hot swap fans | Up to eight hot swap fans | |||
Dimension | Height: 464.0 mm (18.26 inches) (with feet) | Height: 464.0 mm (18.26 inches) (with feet) | ||
446.0 mm (17.60 inches) (without feet) | 446.0 mm (17.60 inches) (without feet) | |||
508.8 mm (20.03 inches) (with caster wheels) | 508.8 mm (20.03 inches) (with caster wheels) | |||
Width — 200.0 mm (7.87 inches) | Width — 200.0 mm (7.87 inches) | |||
Depth — 678.2 mm (26.70 inches) (with bezel) | Depth — 678.2 mm (26.70 inches) (with bezel) | |||
660.6 mm (26 inches) (without bezel) | 660.6 mm (26 inches) (without bezel) | |||
Form Factor | 4.5U tower server | 4.5U tower server | ||
Embedded Management | • iDRAC9 • iDRAC Direct • iDRAC RESTful API with Redfish • iDRAC Service Module • Quick Sync 2 wireless module | • iDRAC9 • iDRAC Direct • iDRAC RESTful with Redfish • iDRAC Service Manual • Quick Sync 2 wireless module NOTE: iDRAC Direct and Quick Sync 2 are available only as an upsell on T550. | ||
Bezel | Security bezel | Optional LCD bezel or security bezel | ||
OpenManage Software | • OpenManage Enterprise • OpenManage Power Manager plugin • OpenManage Service plugin • OpenManage Update Manager plugin • CloudIQ for PowerEdge plug in • OpenManage Enterprise Integration for VMware vCenter • OpenManage Integration for Microsoft System Center • OpenManage Integration with Windows Admin Center | • OpenManage Enterprise • OpenManage Power Manager plug-in • OpenManage SupportAssist plug-in • OpenManage Update Manager plug-in | ||
Mobility | OpenManage Mobile | OpenManage Mobile | ||
Integrations and Connections | • BMC Truesight • Microsoft System Center • OpenManage Integration with ServiceNow • Red Hat Ansible Modules • Terraform Providers • VMware vCenter and vRealize Operations Manager | OpenManage Integrations • BMC TrueSight • Microsoft System Center • Red Hat Ansible Modules • VMware vCenter and vRealize Operations Manager | OpenManage Connections • IBM Tivoli Netcool/OMNIbus • IBM Tivoli Network Manager IP Edition • Micro Focus Operations Manager • Nagios Core • Nagios XI | |
Security | • Cryptographically signed firmware • Data at Rest Encryption (SEDs with local or external key mgmt) • Secure Boot • Secured Component Verification (Hardware integrity check) • Secure Erase • Silicon Root of Trust • System Lockdown (requires iDRAC9 Enterprise or Datacenter) • TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ | • Cryptographically signed firmware • Secure Boot • Secure Erase • Silicon Root of Trust • System Lockdown (requires iDRAC9 Enterprise or Datacenter) • TPM 1.2/2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ | ||
Embedded NIC | 2 x 1 GbE LOM | 2 x 1 GbE LOM | ||
Networking Options | OCP x8 3.0 | OCP x16 Mezz 3.0 | ||
GPU Options | Up to 2 x double-width 300 W or 6 x single-width 75 W accelerators | Up to 2 x double-width 300 W, or 5 x single-width 70 W accelerators | ||
Ports | Front Ports • 1 x USB 2.0 • 1 x USB 3.0 • 1 x iDRAC Direct (Micro-AB USB) port | Rear Ports • 1 x USB 2.0 • 1 x USB 3.0 • 1 x Serial port (optional) • 1 x Dedicated iDRAC management (RJ45) port • 2 x Ethernet ports • 1 x VGA port | Front Ports
There are 2 SKUs: • Base: Status LED only ○ 1 x USB 2.0 ○ 1 x USB 3.0 • Upsell: Status LED only and Quick Sync 2 ○ 1 x USB 2.0 ○ 1 x USB 3.0 ○ 1 x iDRAC Direct (Micro-AB USB) port | Rear Ports • 1 x USB 2.0 • 1 x iDRAC Direct ethernet port • 1 x USB 3.0 • 1 x Serial port (optioanl) • 1 x VGA |
Internal Port : 1 x USB 3.0 (optional) | Internal Port: 1 x USB 3.0 | |||
PCIe | Up to six PCIe slots: 4 x PCIe Gen4 slots and 2 x PCIe Gen5 slots • Slot 1: x16 Gen5 Full height, full length • Slot 2: x16 Gen5 Full height, full length • Slot 3: x16 Gen4 Full height, half length • Slot 4: x16 Gen4 Full height, half length • Slot 5: x16 (with x8 lanes) Gen4 Full height, half length • Slot 6: x16 Gen4 Full height, half length | 3x PCIe Gen4 slots (all x16) + 1x PCIe Gen3 slot (x8) + Upsell: up to 2 PCIe x16 DW for GPU | ||
Operating System and Hypervisors | • Canonical Ubuntu Server LTS • Microsoft Windows Server with Hyper-V • Red Hat Enterprise Linux • SUSE Linux Enterprise Server • VMware ESXi | • Canonical Ubuntu Server LTS • Citrix Hypervisor • Windows Server with Hyper-V • Red Hat Enterprise Linux • SUSE Linux Enterprise Server • VMware ESXi |