Base Standard Capabilities
Product features
Feature | Description | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Processor (One of the following depending on Model) | E5-2600 v2 series Processors
E5-2600 series Processors
| ||||||||||||||||||||||||
Cache memory (One of the following depending on Model) |
| ||||||||||||||||||||||||
Chipset |
| ||||||||||||||||||||||||
Upgradeability |
| ||||||||||||||||||||||||
On System Management Processor | HP iLO (Firmware: HP iLO 4) | ||||||||||||||||||||||||
Memory protection |
| ||||||||||||||||||||||||
Memory (One of the following depending on Model) |
| ||||||||||||||||||||||||
Network controller (One of the following depending on Model) | HP ProLiant Gen8 servers offer a new networking technology - FlexNET Technology. The HP ProLiant DL380p Gen8 server offers the customer the choice of 1 Gigabit and/or 10 Gigabit networking solutions.
| ||||||||||||||||||||||||
Storage controller |
| ||||||||||||||||||||||||
Industry standard compliance |
| ||||||||||||||||||||||||
Graphics | Integrated Matrox G200 video standard
| ||||||||||||||||||||||||
Form factor | 2U Rack form factor | ||||||||||||||||||||||||
System fans |
| ||||||||||||||||||||||||
Interfaces |
| ||||||||||||||||||||||||
Maximum internal storage |
|
Software overview
Feature | Description |
---|---|
Operating systems and virtualization software support for ProLiant servers 1 |
|
NOTE: 1: For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for the server, visit Server Operating Systems and Virtualization Software website. Click here to access Server Operating Systems and Virtualization Software website . |
Physical specifications
Specification | Description |
---|---|
Dimensions (H x W x D)(with bezel) |
|
Weight (approximate) |
|
Electrical specifications
Specification | Description |
---|---|
Rated line voltage |
|
Rated input current |
|
Rated input frequency | 50 to 60 Hz |
Rated input power |
|
BTU Rating maximum |
|
Power Supply Output (per power supply) | |
Rated Steady-State power |
|
Maximum peak power |
|
Environmental specifications
Specification | Description |
---|---|
Operating temperature | 10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 304.8 m (1.8°F per every 1000 ft) above sea level to a maximum of 3048 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). |
Non-operating temperature | -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). |
Shipping temperature | -30° to 50°C (-22° to 122°F) |
Storage temperature | -30° to 60°C (-22° to 140°F) |
Maximum wet bulb temperature | 28°C (82.4°F) |
Operating relative humidity | 10% to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing. |
Non-operating relative humidity | 5% to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing. |
Operating altitude | 3048 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). |
Non- |