Multi-Quantity Discounts Available for ALL Line Items
** LARGE DISCOUNTS available for complete systems. Pricing displayed is for single item purchases **
Use the configuration tool to create your solution and submit it us for a quote OR send us a message with your complete build requirements to receive best pricing
READ ME
- Some options may not be displayed until the compatible parent option is chosen ie. Chassis – Drives, Processor – RAM etc.
- “Submit for Quote” items can be added to your cart and sent to us via the cart page
- Click the blue bar to close/open a section from view after choosing your options
Select Processor
Supports up to 2 4th Gen Intel Xeon ProcessorsCPUs
CPU wattage will dictate the which Heatsink, Fan, or Cooling Module you will need to install.
Platinum
Supports up to 2 CPUs
CPU wattage will dictate the which Heatsink, Fan, or Cooling Module you will need to install.
Gold
Supports up to 2 CPUs
CPU wattage will dictate the which Heatsink, Fan, or Cooling Module you will need to install.
Silver
Supports up to 2 CPUs
CPU wattage will dictate the which Heatsink, Fan, or Cooling Module you will need to install.
Bronze
Supports up to 2 CPUs
CPU wattage will dictate the which Heatsink, Fan, or Cooling Module you will need to install.
Heat sinks / Fans / Cooling Modules
If Performance Heatsink or DLC Module is selected, then Performance Fan must be selected
If DLC Module is selected, then "HPE ProLiant Direct Liquid Cooling 450mm Female-male Connection Quick Disconnect Tube Set FIO Kit (P62046-B21)” must be selected.
If Processor Wattage is between 185W - 270W. "Performance Heatsink" and "Performance Fan" must be selected.
If Processor Wattage is more than 270W, then "Closed Loop Liquid Cooling" or "DLC Module" must be selected.
Max 1 of Liquid cooling can be selected
If NVMe/ SAS4 or Networking/ InfiniBand that is 100G or more or 256GB DIMM or external NS204i-u OS Boot Device, is selected, then Performance Heatsink or Closed Loop Liquid cooling Heatsink or DLC Module must be selected.
If “NS204i-u Cage DLC Module” is selected, then "HPE DL360 Gen11 NS204i-u Rear Cbl Kit" or the "Secondary FH Riser" cannot be selected.
If “PCIe DLC Module” is selected, then either "Secondary LP Riser" must be selected
If “PCIe DLC Module” is selected, then PCIe slot# 3 cannot be used.
If Closed-loop Liquid Cooling HeatSink Fan FIO Bundle Kit is selected, then any Fans (Standard Fan or Heatsink Kit or High Performance Fan or Heatsink Kit) cannot be selected.
Please view the items or read the manual for more requirements and limitations.
Drive cage and backplane (8 SFF CTO server only)
You Must choose a Backplane. Either the x1 PCIe lane Backplane or the x4 Pcie lane Backplane.
Only 1 Additional Add on can be installed at a time. Either the 2SFF or the Media Bay kit that supports an ODD.
Memory
x8 and x4 cannot be mixed.
3DS and non-3DS Memory cannot be mixed.
Mixing of different Rank Memory is not allowed if less than 16 quantity of Memory is selected for 1 Processor
configuration.
Mixing of different Rank Memory is not allowed if less than 32 quantity of Memory is selected for 2 Processor configuration.
If different Rank Memory are mixed, then quantity of each Memory part number must be same.
96GB Memory cannot be mixed with any other Memory.
If 256GB Memory is selected, will be limited to 1P1D, thus Maximum of 8 can be selected per Processor.
If 256GB Memory is selected, then high speed Networking/ InfiniBand card (PCIe and OCP), that is 100G or more, cannot be selected.
If 256GB Memory is selected, will be limited using 7x performance fan or CLC fan (not allow standard fan), and limit at 25C. Or DLC must be selected.
If 256GB Memory is selected without DLC Module, then high speed Networking/ InfiniBand card (PCIe and OCP) that is 100G or more cannot be selected.
Storage Devices (Optional)
Max 2 of PCIe and OROC internal controller can be selected per server.
If any of these controller are selected, then "HPE 96W Smart Stg Li-ion Batt 145mm Kit" or "HPE Smart Hybrid
Capacitor w/ 145mm Cbl" must be selected. Vice versa.
Internal MR-series and Internal SR-series controller cannot be selected together.
If there is no Hardware controller selected, the DL360 Gen11 4LFF SATA Signal Cable Kit (P51897-B21) must be selected in order to support embedded SATA (Direct attach) configuration.
Storage Batteries (Optional)
If "HPE 96W Smart Stg Li-ion Batt 145mm Kit" or "HPE Smart Hybrid Capacitor w/ 145mm Cbl" is selected, then "HPE DL360 Gen11 Stg Cntrl Enable Cbl Kit" must be selected. Vice versa.
Max 1 of Storage Battery can be selected per server.
If "HPE FIO No Smart Storage Battery" is selected, then Battery cannot be selected.
Please view the item or the manual for all the rules.
Storage Cables (Optional)
Max 1 of 8SFF cable can be selected per server.
Max 1 of 2SFF cable can be selected per server.
If 8SFF PCIe cable is selected, then any one of 8SFF Drive cage and PCIe form factor internal controller must be selected.
If 8SFF OROC cable is selected, then any one of 8SFF Drive cage and OCP form factor controller (OROC)
must be selected.
If 2SFF TM cable is selected, then any one of 2SFF Drive cage and any controller (PCIe or OCP form factor)
must be selected.
There are a few rules for these cable kit and requirements.
Please View the item or read the manual for all the details.
RAID Settings (Optional)
RAID 0 requires at least 1 drive.
RAID 1 requires at least 2 or even number of drives.
RAID 1 with Spare requires at least 3 drives
RAID 5 requires at least 3 drives.
RAID 5 with Spare requires at least 4 drives.
RAID 6 requires at least 4 drives.
If RAID is being selected in a configuration with Intel® VROC and internal controller, then Customer Defined RAID Setting (389692-B21) must be selected.
There are so many rules we can't place them here. Please read the Manual below for all the RAID rules.
Optical Drive / Cables (Optional)
Both 9.5MM Optical drives require the optical cable (P48914-B21) to install on 4 LFF models.
Max 1 Optical Drive
SFF SSD Drives (Optional)
Max 8 or 10 Drives, based on what backplanes you have installed.
Any missing drive slots must be filled with a SFF Blank.
SFF HDD Drives (Optional)
Max 8 or 10 Drives, based on what backplanes you have installed.
Any missing drive slots must be filled with a SFF Blank.
NVMe Drives (Optional)
Any NVMe drives need upgraded Cooling
Max 8 or 10 Drives, based on what backplanes you have installed.
Any missing drive slots must be filled with an SFF Blank.
There are many rules about Limiting the amount of NVMe drives that are supported when installing certain Storage Controllers with Boot Devices or Cooling Systems.
Please read the manual for all the details about NVMe drives and the limitations.
Riser Card (Optional)
If a secondary riser is selected, then 2 Processors must be selected.
If the secondary riser and "NS204i-u Rear Cbl Kit" are not selected, then maximum quantity of 2 PCIe cards can be selected.
If a secondary riser is not selected and "NS204i-u Rear Cbl Kit" is selected, then a maximum 1 quantity of PCIe cards can be selected.
If a secondary FH riser is selected, then a maximum quantity of 2 PCIe FH cards can be selected, as primary PCIe Slot 2 cannot be used.
If a secondary FH riser is not selected, then a maximum quantity of 1 of FH PCIe cards can be selected.
If secondary LP riser and "NS204i-u Rear Cbl Kit" are selected, then maximum 2 quantity of PCIe cards can selected.
If secondary LP riser is selected and "NS204i-u Rear Cbl Kit" is not selected, then maximum 3 quantity of PCIe cards can selected.
ports base-T Low Profile NIC adapters are not allowed to be installed at Slot 2 (P51178-B21 & P21106-B21)
GPU max 75W
OCP Enablement (Optional)
In 1 Processor configuration, “CPU1 to OCP2 x8 Enablement Kit” will be selected as default as “BCM5719 Ethernet 1Gb 4-port BASE-T OCP3 Adapter” is pre-selected at OCP Slot 2
In 2 Processor configuration, “CPU2 to OCP2 x8 Enablement Kit” will be selected as default.
To read all the rules either view the items or read the manual below.
InfiniBand PCI / OCP (Optional)
High Performance Fan Kit is required for above 100GB NIC
If 500W Power supply is selected, then x16 Networking/ InfiniBand cannot be selected.
“HPE InfiniBand NDR 1x400Gb OSFP Multi-mode 50m HCA-side Transceiver” is available for “InfiniBand NDR 1-port” & “InfiniBand NDR200 1-port”.
OCP Cards at the bottom
Ethernet Adapter PCIe/OCP (Optional)
OCP 3.0 Adapters are at the bottom of the list.
Please look over the manual for ambient temps and other requirements.
Fibre Channel HBA (Optional)
GPU (Optional)
Mixing of different Graphics Option is not allowed.
Requires “Increased Cooling” to be selected in BIOS settings (defualt setting is “Optimal Cooling”).
There is no Energy Star 3.0 certification with Graphic cards.
If GPU is selected, standard heatsink & stanrd fan kits are not supported. Requires high performance fans.
If GPU is selected for best performance across common workloads, HPE recommends system main memory at least twice the memory of all GPU.
Transceiver (Optional)
There are many specs for these Transceivers, Please read the Spec Manual below or view the items to see all the specs about each transceiver.
Security (Optional)
If Bezel lock is selected, then "HPE DL3XX Gen11 1U Bezel Kit" or "HPE OEM Gen11 1U Bezel KIT" must be selected.
Rail Kit (Optional)
Rail Kit does not include Cable Management Arm.
Power Cooling (Optional)
Mixing of 2 different power supplies is NOT supported.
Helpful Tip: Once desired configuration is selected click "Add to Cart". From the cart page you can submit a submit a quote request for best pricing
The HPE ProLiant DL360 Gen11 server is a rack-optimized 1U dense solution that delivers exceptional compute performance, upgraded high-speed data transfer rate, and memory depth with 2P compute capability. Powered by 4th Gen Intel® Xeon® Scalable processors with up to 60 cores, increased memory bandwidth, up to 8 TB of memory, and high-speed PCIe Gen5 I/O, the HPE ProLiant DL360 Gen11 server is a perfect rack-optimized, 1U 2P, dense solution for general-purpose virtualization workloads that require increased compute density with built-in security and flexibility.
The silicon root of trust anchors the server firmware to an HPE-exclusive ASIC, creating an immutable fingerprint for the Secure Intel Processor that must be matched exactly before the server will boot. The HPE ProLiant DL360 Gen11 server is an excellent choice for EDA, CAD, and VDI.
There are Three Chassis to choose from.
Know your Server - CTO Configuration Support
Need help with the configuration? Contact us today!
HPE ProLiant DL360 Gen11 Base Knowledge
Since this Server is so large and has so many configurations, we have broken it up by chassis to make this information a little easier for you to digest.
Chassis
- 8SFF x1 U.3 Tri-Mode Backplane Kit
- 8SFF x4 U.3 Tri-Mode Backplane Kit
- With options for additional 2SFF x4 U.3 BC Tri-Mode Enablement Kit
- With options for additional Display Port/USB/Optical Drive Blank Kit
Processor
The DL360 Gen11 supports the 4 th Gen Intel Xeon Processor with up to 80 cores. CTO server will populate necessary fan kits per system thermal requirements and processor models, minimum of 5 standard fans. Dual processor configurations require 7 fans, either standard or high-performance.
Some Processors can only be installed in a single socket configuration.
- Gold 6421N Processor
- Gold 6414U Processor
- Gold 5411N Processor
Processor Suffix |
Description |
Offering |
H |
DB and Analytics |
Highest core counts. Database and Analytics usages benefit from DSA and IAA accelerators. |
M |
Media Transcode |
Optimized around AVX frequencies to deliver better performance/watt around Media, AI, and HPC workloads. |
N |
Network/5G/Edge (Hight TPT/Low latency) |
Designed for NFV and networking workloads, such as: L3 forwarding, 5G UPF, OVS DPDK, VPP FIB router, VPP IPsec, web server/NGINX, vEPC, vBNG, and vCMTS. |
S |
Storage and HCI |
Optimized for Storage UMA use cases with increased UPI Bandwidth for vs Mainline SKUs. |
P |
Cloud - IaaS |
Designed for cloud IaaS environments to deliver higher frequencies at constrained TDPs. |
Q |
Liquid Cooling |
Liquid cooled processors with higher frequency and performance at same TDP. |
U |
One Socket Optimized |
Optimized for targeted platforms adequately served by the cores, memory bandwidth and IO capacity. Available from a single processor configuration. |
V |
Cloud- SaaS |
Optimized for orchestration efficiency that delivers higher core counts and VMs per rack. |
Y |
Speed Select1 |
Intel® SST-Performance Profile (PP) increases base frequency when fewer cores are enabled. Allows greater flexibility, deployment options and platform longevity. |
Heatsink & Fans
This DL360 Gen11 Rack Server has many fans and heat sink options based of the TDP of the processor. Below is a table showing you the TDP and which Heatsink / Fan system will be supported.
Cooling Option selection in 8+2 SFF and 4LFF CTO Servers |
CPU TDP (Watts) |
125W – 185W |
186W – 270W |#1 |
271W – 350W |#1 |
350W (LC CPU) |
CPU QTY |
1 |
2 |
2 |
2 |
2 |
2 |
Heatsink |
Standard (P48904-B21) |
High Performance (P48905-B21) |
Closed-loop LC Heatsink and Fan FIO Bundle Kit 3 (P48906-B21) |
Direct Liquid Cooling (DLC) Heatsink and High-Performance Fan (P48908-B21) FIO solution |
Fans |
Standard Fan (P48907-B21) |
Standard Fan (P48907-B21) & |
High Performance (P48908-B21) |
2 CPU Standard Fan (P54697-B21) |
Max DIMM |
32x128GB |
32x128 GB or 16x256GB |
16x256GB |
Networking |
10/25GbE PCIe adapter or OCP |
Max Drive |
4LFF SAS or 8+2 NVMe |
8SFF CTO Svr with 0 backplane & 0 drive, 25C |
4LFF SAS or 10NVMe |
No support for 4LFF CTO Server |
Internal OS Boot |
Available for internal NS204i-u |
External OS Boot |#6 |
Available |
30C (4LFF SAS); 30C (8NVMe); |
25C |
Available |
No support, 23C (10 NVMe) |
Alternatives |
Direct Liquid Cooling (DLC) Heatsink and High-Performance Fan FIO solution, for all processors in 2P Configuration. Support up to 32x256GB DIMM, Internal / external NS204i-u, 10x NVMe |
DIMM blanks |
Required, embedded, and shipped as default in all CTO Servers |
Max 1 of the Liquid cooling bundle kit below can be selected:
- Closed Loop Liquid Cooling (P48906-B21)
- DLC Module from NS204i-u Cage (P62026-B21)
- DLC Module from PCIe slot (P62029-B21)
- Required for all DLC in order to function: HPE Rack, Rack Manifold, CDU, Primary Hose Kit, and Secondary Hose Kit
If the DLC Module from NS204i-u Cage (P62026-B21) is selected then both the following are not supported.
- HPE DL360 Gen11 NS204i-u Rear Cbl Kit
- Secondary FH Riser
If the DLC Module from PCIe slot (P62029-B21) is selected then one of the Secondary Risers must be installed and the PCIe slot# 3 cannot be used.
Options listed below would require a Performance Fan kit or Direct Liquid Cooling bundle kit to be implemented.
- CPU TDP (as above table shows)
- 256GB DIMM
- NIC and InfiniBand adapters and OCP cards that go beyond 100GbE/200GbE
- NVMe storage (even Qty 1)
- With GPU
- With hot-plug (external) OS Boot Device NS204i-u
Memory
Maximum capacity (RDIMM) 8.0 TB 32 x 256 GB RDIMM @ 4800 MT/s
Mixing of DIMM types (UDIMM, RDIMM, and LRDIMM) is not supported.
This DL360 Gen 11 can hold up to a total of 8TB of DDR5 memory on 32 DIMMs in a 2-socket configuration. 16 DIMMs per processor.
All DIMMs in a Processor socket must have the same number of ranks (unless explicitly specified otherwise). x8 DIMMs and x4 DIMMs cannot be mixed in the same channel or same Processor socket.
Mixing vendor is allowed for RDIMMs, but it is not allowed for 3DS RDIMMS
If a 350W CPU is selected with Closed Loop Liquid cooling, then 256GB DIMM cannot be selected.
If 256GB of Memory is selected, and without DLC Module. Then a high-speed Networking/ InfiniBand card (PCIe and OCP) that is 100G or more cannot be selected.
If 256GB Memory is selected, will be limited using 7x performance fan or Closed Loop Liquid Cooling fan (not allow standard fan)
All empty DIMM slots must have a HPE DDR4 DIMM Blank Kit (P07818-B21) installed.
RAID Controller
Choice of Intel® VROC Software RAID or HPE ProLiant Gen11 MR and SR PCIe or OCP plug-in Controller. If any of these controllers are selected, then "HPE 96W Smart Stg Li-ion Batt 145mm Kit (P01366-B21 )" or "HPE Smart Hybrid Capacitor w/ 145mm Cbl (P02377-B21 )" must be selected. Vice versa. Now if any of these Storage Batteries get selected. They also need the HPE ProLiant DL360 Gen11 Storage Controller Enablement Cable Kit (P48918-B21).
For 8SFF CTO Model: If MR408i-o is the only controller selected, then 8SFF cable kit cannot be selected for 8SFF x4 drive cages.
For 8SFFx4 U.3 drive cage selection with 2SFF Drive cage: If MR416i-p/ MR216i-p and MR416i-o/ MR216i-o/ MR408i-o are selected, then both "HPE DL360 Gen11 8SFF PCIe Cbl Ki/ P48909-B21 or HPE DL360 Gen11 OROC TM Cbl Kit/ P52416-B21" and "HPE DL360 Gen11 2SFF TM Cbl Kit/ P48910-B21" must be selected.
Requires 8 SFF cables (P48909-B21 HPE ProLiant DL360 Gen11 8SFF PCIe Controller Cable Kit) for Tri-Mode PCIe standup controllers.
Prioritization list for Primary controller selection in HPE ProLiant DL360 Gen11 8SFF NC CTO Server (P52499-B21) is as follows:
- HPE SR932i-p Gen11 24G Controller Kit
- HPE MR416i-o Gen11 12G Controller Kit
- HPE MR416i-p Gen11 12G Controller Kit
- HPE MR408i-o Gen11 SPDM Storage Cntlr
- HPE MR216i-o Gen11 12G Controller Kit
- HPE MR216i-p Gen11 12G Controller Kit
- Intel® VROC
- Direct Attach
If only 1 OROC card is selected, by default connected from 8SFF backplane to OCP Slot1. And there is no controller cable can connect from 8SFF Backplane to OCP Slot 2.
If 2 OROC cards are selected, by default the 8SFF controller cable is connected to OCP Slot1 (the comparably higher-end OROC card to be selected by default) and the 2SFF backplane is connected to OCP Slot2 with another OROC card selected (comparably less high-end one) with 2FF controller cable.
If "HPE FIO No Smart Storage Battery (P06141-B21 )" is selected, then SR932/ MR416/ MR408 controller must be selected.
If RAID is selected and both SAS AND SATA drives are configured, then only the SAS drives will be used in the RAID set. (SAS drives must be the same part number; SATA drives can vary in part numbers).
If RAID is being selected in a configuration with Intel® VROC and an internal controller, then Customer Defined RAID Setting (389692-B21) must be selected.
There are a lot of rules with RAID in the PDF Manual. I recommend you reading the manual to understand all the requirements and limitations of RAID in this system.
Software RAID Controller (VROC) SATA
- RAID Support- 0/1/5/10.
- Intel® VROC SATA is off by default and must be enabled.
Maximum Storage |
Storage |
Capacity |
Configuration |
Hot Plug SFF SAS HDD |
24.0 TB |
8+2 x 2.4 TB (with optional 2 SFF cage on UMB) |
Hot Plug SFF SATA HDD |
20.0 TB |
8+2 x 2.0 TB (with optional 2 SFF cage on UMB) |
Hot Plug SFF SAS SSD |
15.3 TB |
8+2 x 15.36 TB (with optional 2 SFF cage on UMB) |
Hot Plug SFF SATA SSD |
76.8 TB |
8+2 x 7.68 TB (with optional 2 SFF cage on UMB) |
Hot Plug SFF U.3 NVMe PCIe SSD |
153.6 TB |
8+2 x 15.36 TB (with optional 2 SFF cage on UMB) |
Hot Plug LFF SAS HDD |
80.0 TB |
4 x 20 TB |
Hot Plug LFF SATA HDD |
80.0 TB |
4 x 20 TB |
Hot Plug LFF SAS SSD |
30.72 TB |
4 x 7.68 TB |
Hot Plug LFF SATA SSD |
3.84 TB |
4 x 960 GB |
M.2 NVMe SSD |
960 GB |
2 x 480 GB (shipped with optional HPE NS204i-u Gen11 NVMe Hot Plug Boot Optimized Storage Device ): Available with external or internal version |
EDSFF MVMe SSD |
307.2TB |
20 x 15.36 TB |
Expansion Slots
The HPE DL360 Gen 11 has advanced data transfer rates and higher network speeds from the PCIe Gen5 serial expansion bus, with up to 3 x16 PCIe Gen5 and 2 OCP slots.
The system can hold up to 3 PCIe 5.0 slots on two risers. The first riser is a default butterfly riser that comes with the chassis. The default riser is controlled by the first CPU and has two PCIe 5.0 x16 slots. Slot 1 is a full-height while slot 2 is a half-height slot.
The second riser has two options to choose from. One option is the FH Riser makes Slot 2 on Riser 1 not available while the LP Riser does make slot 2 available. With the second option, you are able to get all 3 PCIe 5.0 slots integrated.
If you install the NS204i-u Rear Cable Kit (P54702-B21), then slot 2 of riser 1 will not be available since this is where that card can be installed. You do have another option of installing this Ns204i-u internally (P48920-B21). This OS Boot device includes 2x 480GB M.2 NVMe SSDs, with preconfigured hardware RAID1.
Riser Information |
Part Number |
Description |
Riser Position |
Slot Bus Width (Gen5 Lanes) |
GPU Support |
NVMe Direct Connect |
M.2 Connect |
Prim. |
Sec. |
#1 |
#2 |
#3 |
Connectors |
Max SSDs |
(default in chassis) |
HPE DL360 Gen11 x16/x16 Primary Riser |
D |
N/A |
x16 |
x16 |
N/A |
Y |
N/A |
N/A |
N/A |
P48901-B21 |
HPE ProLiant DL360 Gen11 x16 Full Height Riser Kit |#1 |
N/A |
O |
N/A |
N/A |#1 |
x16 |
Y |
N/A |
N/A |
N/A |
P48903-B21 |
HPE ProLiant DL360 Gen11 x16 LP Riser Kit |
N/A |
O |
N/A |
N/A |
x16 |
Y |#2 |
N/A |
N/A |
N/A |
1 #1 | If secondary FH riser is selected, then maximum 2 quantity of PCIe FH cards can be selected, as primary PCIe Slot 2 cannot be used. #2 | GPU max 75W |
PCIe Expansion Slots |
Primary Riser (default in chassis) |
Expansion Slots # |
Technology |
Bus Width |
Connector Width |
Processor |
Slot Form Factor |
1 |
PCIe 5.0 |
x16 |
x16 |
CPU 1 |
Full-height, up to 9.5” length (or half-length card) |
2 |
PCIe 5.0 |
x16 |
x16 |
CPU 1 |
Half-height (Low-profile), up to 9.5” length (or half length card) |
Secondary Riser |
3 |
PCIe 5.0 |
x16 |
x16 |
CPU 2 |
Full-height, up to 9.5” length (or half-length card). Slot 2 will be not available. |
Half-height (Low-profile), up to 9.5” length (or up half length card). Slot 2 is available. |
GPU
Supports up to 2 single wide (SW) GPUs to accelerate graphic intense workloads. Mixing of different Graphics Option is not allowed. Requires high performance fans.
Integrated Lights-Out 6 (iLO 6)
Software that enables you to securely configure, monitor, and update your HPE ProLiant Gen11 servers seamlessly, from anywhere.
Embedded in Hewlett Packard Enterprise servers, HPE Integrated Lights-Out 6 (iLO 6) is an exclusive core intelligence that monitors server status, providing the means for reporting, ongoing management, service alerting, and local or remote management to quickly identify and resolve issues.
Fan Units
Supports Smart Cooling Modules for highest thermal design points (TDPs)
The DL360 Gen11 will support up to 7 fans with fan redundancy built in. One fan rotor failure will place server in degraded mode but fully functional. Two fan rotor failures could provide warning and imminent server shutdown.
Standard Fan Kit: Dual rotor hot plug Standard Fan kit (includes 5 fans) for processors below 185W TDP.
Optional 2P standard Fan Kit: Dual rotor hot plug 2P Standard Fan Kit (includes 2 fans) for second processor.
Performance Fan Kit (P48908-B21): Dual rotor hot plug High Performance Fan Kit available (includes 7 fans), for one or two processors from 186W to 270W TDP. Or one processor with 300W TDP.
Closed-loop Liquid Cooling Heat Sink Fan FIO Bundle Kit (P48906-B21) supports one or two processors go beyond 271W TDP, as a factory installation kit only. Customer self-repair or self-field upgrade is not allowed. If Closed-loop Liquid Cooling HeatSink Fan FIO Bundle Kit is selected, then any Fans (Standard Fan Kit or High Performance Fan Kit) cannot be selected.
Direct Liquid Cooling Heatsink Fan FIO Bundle Kit supports two processors go beyond 271W TDP, with enhanced thermal condition.
Power
HPE Flexible Slot (Flex Slot) Power Supplies share a common electrical and physical design that allows for hot plug, tool-less installation into HPE ProLiant Gen11 Performance Servers. Flex Slot power supplies are certified for high-efficiency operation and offer multiple power output options, allowing users to "right-size" a power supply for specific server configurations. This flexibility helps to reduce power waste, lower overall energy costs, and avoid "trapped" power capacity in the data center.
Mixing of 2 different power supplies is NOT supported.
HPE 1600W Flex Slot -48VDC Hot Plug Power Supply Kit (P17023-B21). If 1600W DC Power supply is selected, then either "HPE 1600W DC PSU Power Cable Kit (P22173-B21)" or "HPE 1600W DC PSU Power Lug Option Kit (P36877-B21)" must be selected and the quantity must match. vice versa. Both "HPE 1600W DC PSU Power Lug Option Kit" and "HPE 1600W DC PSU Power Cable Kit" cannot be selected together.
Dimensions & Weight:
SFF Drives (Height x Width x Depth)
- 29 x 43.46 x 75.31 cm
- 69 x 17.11 x 29.65 in
EDSFF Drives (Height x Width x Depth)
- 29 x 43.46 x 77.31 cm
- 69 x 17.11 x 30.43 in
Weight (approximate)
14.56 kg (32.1 lb)
- SFF minimum: One drive, one processor, one power supply, two heatsinks, one Smart Array controller, and five fans.
20.44 kg (45.07 lb)
- SFF maximum: Ten drives, two processors, two power supplies, two heatsinks, one Smart Array controller, and seven fans.
14.75kg (32.51lb)
- EDSFF minimum: One drive, two processors, one power supply, two heatsinks, one Smart Array controller, and seven fans.
21.19kg (46.71lb)
- EDSFF maximum: Twenty drives, two processors, two power supplies, two heatsinks, one Smart Array controller, and seven fans.