Current Configuration
(List below serves as quick links to each section)
Select Chassis
Select Processor
Bezel
Memory
Storage Controllers
HDD (3.5\") Drives
HDD (2.5\") Drives
SSD (2.5\") Drives
SSF NVMe Drives
GPU
OCP 3.0
Boot Optimized Storage Subsystem (BOSS-N1):
IDSDM
Internal USB
Trusted Platform Module
iDRAC9
Power Supplies
ECS Warranty
The request has been sent.
Thank you.
Price as Configured:
$0
Price as Configured:
$0
Tower server | 4.5U (Rackable)
Processor | Max: 32 Cores2x Gen 4 Intel Xeon Scalable Processors
Memory | Max: 1TB16 DDR5 RDIMM 4800Mhz
Storage | Max: 360TB12x 3.5" SAS/SATA (HDD/SSD) Max: 180 TB
8x 3.5" SAS/SATA (HDD/SSD) Max: 120 TB
8x 3.5" SAS/ SATA (HDD/SSD) + 8 x 2.5-inch NVMe SSD Max: 240 TB
8x 2.5" SAS/SATA (HDD/SSD) Max: 120 TB
16x 2.5" SAS/SATA (HDD/SSD) Max: 240 TB
24x 2.5" SAS/SATA (HDD/SSD) Max: 360 TB
Boot Optimized Server Storage (BOSS-N1)
IDSDM
Internal USB
S160 (for NVMe drives only)
fPERC H965i, H755N, H755, H355, HBA355i, HBA355e (non-RAID), H840
1 x OCP 3.0
2 x 1GbE LOM on Planar
Note: The system allows both LOM on Planar and OCP card to be installed on the system.
iDRAC9 with Lifecycle Controller
PCIe Slots:Up to six PCIe slots:
• Slot 1: x16 Gen5 FH, FL
• Slot 2: x16 Gen5 FH, FL
• Slot 3: x16 Gen4 FH, HL
• Slot 4: x16 Gen4 FH, HL
• Slot 5: x16 (x8 lanes) Gen4 FH, HL
• Slot 6: x16 Gen4 FH, HL
2x 300 W DW or 6x 75 W SW
(Click to View)
- Big Data Analytics
- Cloud Servers
- Edge Servers
- Virtualization
The Dell PowerEdge T560, powered by the 4th Generation Intel® Xeon® Scalable processors, is an enterprise-class tower server that offers advanced technologies with accelerators. It is a purpose-built server with office-friendly acoustics that maximizes next-gen technologies to achieve optimal performance in a small footprint. The Dell PowerEdge T560 is an ideal tower server for traditional corporate IT, virtualization, database and analytics, and inferencing for AI/ML, delivering robust compute performance.
Experience balanced expandability and performance for enterprise-level workloads.
- Database applications with expanded storage with up to 12 x 3.5” drives and faster I/O with PCIe Gen5
- Virtualization and AI inferencing with up to two Intel® Xeon® Scalable processors, DDR5 memory and up to 6 GPUs
- Office settings and applications with easy deployment and quiet acoustics
- Enterprise-level security requirements with cyber-resilience to store, process and analyze data
Made to scale
- Maximize your performance with faster 4th Generation Intel® processors, higher bandwidth DDR5, better performance with PCIe Gen 5 and PERC 12
- Flexible and balanced storage capacity with up to 12 x 3.5’’ or 24 x 2.5’’ drives, allowing a mix of HDD, SSD and NVMe support
- Provide mainstream datacenter level cyber-resiliency to store, process and analyze data in a small footprint
This all-in-one powerhouse provides ease of management and expandability for growth and performance.
- Provides additional support for database applications with expanded storage with up to 12 x 3.5-inches drives and 24 x 2.5-inches drives allowing for a mix of HDD, SAS4 SSD, and NVMe support.
- Virtualization and AI inferencing capabilities with up to two Xeon Scalable processors, doubled-bandwidth DDR5 memory, double-speed PCIe Gen5, and up to 6 GPUs.
- Achieves enterprise-level security requirements with cyber-resilience to store, process and analyze data.
Cyber Resilient Architecture for Zero Trust IT environment & operations
Security is integrated into every phase of the PowerEdge lifecycle, including protected supply chain and factory-to-site integrity assurance. Silicon-based root of trust anchors end-to-end boot resilience while Multi-Factor Authentication (MFA) and role-based access controls ensure trusted operations
- 12x 3.5" SAS/SATA HDD drives, max 180 TB
- 8x 3.5" SAS/SATA HDD drives, max 120 TB
- 8x 3.5" SAS/ SATA HDD + 8 x 2.5-inch NVMe SSD drives, max 240 TB
- 8x 2.5" SAS/SATA HDD drives, max 120 TB
- 16x 2.5" SAS/SATA HDD drives, max 240 TB
- 24x 2.5" SAS/SATA HDD drives, max 360 TB

If you install a CPU with a TDP over 150W you will need the High-Performance Heat Sink (HPR HSK) if it's 150 or less then the standard heat sink will be installed. All GPU’s need a high-performance heat sink and Fans. Depending on the wattage used by the GPU you will either need 4 or 7 fans installed. You can find more information in the tech manual under the “Thermal Restrictions”

With a Max of 8 DIMMs per processor and a total of 16 DIMMs per system. Supporting up to 1TB of 4800Mhz DDR5 ECC RDIMM Memory. Keep in mind there is no mixing of DIMMs and a minimum of 1 DIMM must be populated for each installed processor.
| DIMM Capacity (GB) | DIMM Type | Ranks per DIMM | Rated DIMM Speed (MT/s) | Data Width | DIMM Volts (V) |
|---|---|---|---|---|---|
| 16 | RDIMM | 1 | 4800 | x8 | 1.1 |
| 32 | RDIMM | 2 | 4800 | x8 | 1.1 |
| 64 | RDIMM | 2 | 4800 | x4 | 1.1 |
The Dell PowerEdge T560 Tower Sever has up to six PCIe slots. 4 x PCIe Gen4 slots and 2 x PCIe Gen5 slots will accommodate all the expanding configurations you have. The system has 4 PCIe slots on the system board and 2 Riser Cards for GPU support. Riser 1 holds 1 GPU and Riser 2 holds 2 GPUs.
Up to 2 x double-width 300 W or 6 x single-width 75 W. All GPU configurations will need to upgrade the fans from standard to high performance.
| Config No. | Riser configuration | No. of Processors | PERC type supported | Rear storage possible |
|---|---|---|---|---|
| 0 | N/A | 2 | fPERC | No |
| 0-1 | N/A | 2 | fPERC | No |
| 1 | 1 x GPU Riser | 2 | fPERC | No |
| 1-1 | 1 x GPU Riser | 2 | fPERC | No |
| 2 | 2 x GPU Riser | 2 | fPERC | No |
The Dell PowerEdge T560 comes with an onboard LOM board, 2x1Gb with BCM5720 LAN controller, and 1 optional OCP Mezz 3.0 (supported by x8 PCIe lanes).
The OCP has an Air Shroud that needs to be installed whether or not the OCP card is installed. The OCP card can handle up to 4 Ports at 25Gb for a total of 100Gb of networking capacity on a single OCP 3.0 card.

| Feature | OCP 3.0 |
|---|---|
| Form factor | SFF |
| PCIe Gen | Gen4 |
| Max PCIe width | x8 |
| Max no. of ports | 4 |
| Port type | BT/SFP/SFP+/SFP28/SFP56 |
| Max port speed | 100 GbE |
| NC-SI | Yes |
| SNAPI | Yes |
| WoL | Yes |
| Power consumption | 15 W–150 W |
The T560 Tower Server supports PERC 11 / 12 Storage Controllers. The main configuration for this system is to utilize the fPERC for raid so it frees up a PCIe slot for either a GPU or for expanding the networking ability of the server.
The 3.5" and 2.5" backplanes have different spots for the fPERCs. The 3.5" fPERC is on the front of the chassis in a dedicated slot. The 2.5" fPERC sits on the rear of the backplane. For more information about installing the fPERC Storage Controllers, please read the manuals below.

| Performance Level | Controller and Description |
|---|---|
| Entry | S160 (Software RAID: NVMe) |
| Value | H355, HBA355 (internal/external) |
| Value Performance | H755, H755N |
| Premium Performance | H965i, Avenger 1 Memory: 8GB DDR4 NV cache 72-bit memory 2133 MHz Low profile form factors Dual A15 1.2 GHz CPU X8PCIe 3.0, x8 12Gb SAS |
The system has 4 PCIe slots on the system board and 2 Riser Cards for GPU support. Riser 1 holds 1 GPU and Riser 2 holds 2 GPUs.
Up to 2 x double-width 300 W or 6 x single-width 75 W. All GPU configurations will need to upgrade the fans and heat-sinks from standard to high performance.
To find more information please read the manual and look up the "Thermal Restriction Matrix"

Dell PowerEdge T560 supports 2 hot swap redundant PSUs.
- 2400W Platinum 100—240 VAC or 2400 W 240 VDC
- 1800W Titanium 200—240 VAC or 1800 W 240 VDC
- 1400W Platinum 100—240 VAC or 1400 W 240 VDC
- 1100W Titanium 100—240 VAC or 1100 W 240 VDC
- 1100 LVDC -48 — (-60) VDC
- 800W Platinum 100—240 VAC or 800 W 240 VDC
- 700W Titanium 200—240 VAC or 700 W 240 VDC
- 600W Platinum 100—240 VAC or 600 W 240 VDC
Dimensions
Width: 200.0 mm (7.87 inches)
Height:
464.0 mm (18.26 inches) (with feet)
446.0 mm (17.60 inches) (without feet)
508.8 mm (20.03 inches) (with caster wheels)
Length:
678.2 mm (26.70") (with bezel)
660.6 mm (26") (without bezel)
- 12x 3.5" (SAS/SATA) 48 kg (107.32 lb)
- 8x 3.5" (SAS/SATA) 43.16 kg (95.15 lb)
- 8x 3.5" (SAS/SATA) + 8 x 2.5" NVMe 46.84 kg (103.26 lb)
- 8x 2.5" (SAS/SATA) 39.40 kg (86.86 lb)
- 16x 2.5" (SAS/SATA) 42.02 kg (92.63 lb)
- 24x 2.5" (SAS/SATA) 44.64 kg (98.41 lb)
Current Configuration
(List below serves as quick links to each section)
Select Chassis
Select Processor
Bezel
Memory
Storage Controllers
HDD (3.5\") Drives
HDD (2.5\") Drives
SSD (2.5\") Drives
SSF NVMe Drives
GPU
OCP 3.0
Boot Optimized Storage Subsystem (BOSS-N1):
IDSDM
Internal USB
Trusted Platform Module
iDRAC9
Power Supplies
ECS Warranty
The request has been sent.
Thank you.
Price as Configured:
$0
Base Standard Capabilities
| Feature | Technical Specifications | |
|---|---|---|
| Processor | Up to two 4th Generation Intel® Xeon Scalable processor, with up to 32 cores per processor and optional Intel® QuickAssist Technology | |
| Memory | • 16 DDR5 DIMM slots, supports RDIMM 1 TB max, speeds up to 4800 MT/s • Supports registered ECC DDR5 DIMMs only | |
| Storage controllers | • Internal PERC: fPERC H965i, fPERC H755N, fPERC H755, fPERC H355, fPERC HBA355i • Internal Boot: Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSD drives, or USB • External HBA (non-RAID): PERC HBA355e • Software RAID: S160 (for NVMe drives only) | |
| Drive Bays | Front bays: • Up to 12 x 3.5-inch SAS/SATA HDD drives, max 180 TB • Up to 8 x 3.5-inch SAS/SATA HDD drives, max 120 TB • Up to 8 x 3.5-inch SAS/ SATA HDD + 8 x 2.5-inch NVMe SSD drives, max 240 TB • Up to 8 x 2.5-inch SAS/SATA HDD drives, max 120 TB • Up to 16 x 2.5-inch SAS/SATA HDD drives, max 240 TB • Up to 24 x 2.5-inch SAS/SATA HDD drives, max 360 TB | |
| Power Supplies | • 2400 W Platinum 100—240 VAC or 2400 W 240 VDC, hot swap redundant • 1800 W Titanium 200—240 VAC or 1800 W 240 VDC, hot swap redundant • 1400 W Platinum 100—240 VAC or 1400 W 240 VDC, hot swap redundant • 1100 W Titanium 100—240 VAC or 1100 W 240 VDC, hot swap redundant • 1100 LVDC -48 — (-60) VDC, hot swap redundant • 800 W Platinum 100—240 VAC or 800 W 240 VDC, hot swap redundant • 700 W Titanium 200—240 VAC or 700 W 240 VDC, hot swap redundant • 600 W Platinum 100—240 VAC or 600 W 240 VDC, hot swap redundant | |
| Cooling Options | Air cooling | |
| Fans | • Up to eight Standard (STD) fans or High performance (HPR) fans | |
| Dimensions | • Height — 464.0 mm (18.26 inches) (with feet) 508.8 mm (20.03 inches) (with caster wheels) 446.0 mm (17.60 inches) (without feet) • Width — 200.0 mm (7.87 inches) • Depth — 678.2 mm (26.70 inches) (with bezel) 660.6 mm (26 inches) (without bezel) | |
| Form Factor | 4.5U tower server | |
| Embedded Management | • iDRAC9 • iDRAC Direct • iDRAC RESTful API with Redfish • iDRAC Service Module • Quick Sync 2 wireless module | |
| Bezel | Optional security bezel | |
| OpenManage Software | • OpenManage Enterprise • OpenManage Power Manager plugin • OpenManage Service plugin • OpenManage Update Manager plugin • CloudIQ for PowerEdge plug in • OpenManage Enterprise Integration for VMware vCenter • OpenManage Integration for Microsoft System Center • OpenManage Integration with Windows Admin Center | |
| Mobility | OpenManage Mobile | |
| OpenManage Integrations | • BMC Truesight • Microsoft System Center • OpenManage Integration with ServiceNow • Red Hat Ansible Modules • Terraform Providers • VMware vCenter and vRealize Operations Manage | |
| Security | • Cryptographically signed firmware • Data at Rest Encryption (SEDs with local or external key mgmt) • Secure Boot • Secure Erase • Secured Component Verification (Hardware integrity check) • Silicon Root of Trust • System Lockdown (requires iDRAC9 Enterprise or Datacenter) • TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ | |
| Embedded NIC | 2 x 1GbE LOM on Planar | |
| Network Options | 1 x OCP x8 card 3.0 Note: The system allows both LOM on planar and OCP card to be installed on the system. | |
| GPU Options | Up to 2 x 300 W DW or 6 x 75 W SW | |
| Ports | Front Ports • 1 x USB 2.0 • 1 x USB 3.0 • 1 x iDRAC Direct (Micro-AB USB) port | Rear Ports • 1 x USB 2.0 • 1 x USB 3.0 • 1 x Serial port (optional) • 1 x Dedicated iDRAC (RJ45) port • 1 x VGA port • 2 x Ethernet ports |
| Internal Ports • 1 x USB 3.0 (optional) | ||
| PCIe | Up to six PCIe slots: • Slot 1: x16 Gen5 Full height, Full length • Slot 2: x16 Gen5 Full height, Full length • Slot 3: x16 Gen4 Full height, Half length • Slot 4: x16 Gen4 Full height, Half length • Slot 5: x16 (x8 lanes) Gen4 Full height, Half length • Slot 6: x16 Gen4 Full height, Half length | |
| Operating System and Hypervisors | • Canonical Ubuntu Server LTS • Microsoft Windows Server with Hyper-V • Red Hat Enterprise Linux • SUSE Linux Enterprise Server • VMware ESXi | |
Spec Sheet 4
| Feature | PowerEdge T560 | PowerEdge T550 | ||
|---|---|---|---|---|
| Processors | Up to two 4th Generation Intel ® Xeon Scalable processors with up to 32 cores per processor | Up to two 3rd Generation Intel Xeon Scalable processors with up to 32 cores | ||
| Memory | DIMM Speed
• Up to 4800 MT/s Memory Type • RDIMM Memory module slots • 16 DDR5 DIMM slots • Supports registered ECC DDR5 DIMM slots only Maximum RAM • RDIMM 1TB |
DIMM Speed
• Up to 3200 MT/s Memory Type • RDIMM Memory module slots • 16 DDR4 DIMM slots • Supports registered ECC DDR4 DIMM slots only Maximum RAM • RDIMM 1TB |
||
| Storage Controllers | • Internal PERC: fPERC HBA355i, fPERC H755, fPERC
H755N, fPERC H355, fPERC H965i
• Internal Boot: Boot Optimized Storage Subsystem (BOSS- N1): HWRAID 2 x M.2 NVMe SSDs drives, or USB • External HBA (non-RAID): PERC HBA355e • Software RAID: S160 (NVMe only) |
• Internal controllers: PERC H345,
PERC H755, H755N, HBA355i
• Internal Boot: Internal Dual SD Module or Boot Optimized Storage Subsystem (BOSS-S2): HWRAID 2 x M.2 SSDs or USB • External Controller (RAID): PERC H840 • External HBAs (non-RAID): HBA355e • Software RAID: S150 |
||
| Drive Bays | Front bays:
• Up to 12 x 3.5-inch SAS/SATA HDD drives, max 180 TB • Up to 8 x 3.5-inch SAS/SATA HDD drives, max 120 TB • Up to 8 x 3.5-inch SAS/ SATA HDD + 8 x 2.5-inch NVMe SSD drives, max 240 TB • Up to 8 x 2.5-inch SAS/SATA HDD drives, max 120 TB • Up to 16 x 2.5-inch SAS/SATA HDD drives, max 240 TB • Up to 24 x 2.5-inch SAS/SATA HDD drives, max 360 TB |
Front bays:
• Up to 8 x 2.5-inch SAS/SATA (hard drive) max 120 TB • 16 x 2.5-inch SAS/SATA (HDD) max 240 TB • 24 x 2.5-inch SAS/SATA (HDD)max 360 TB • 8 x 3.5-inch SAS/SATA (HDD/SAS) max 120 TB • 8 x 3.5-inch SAS/SATA (HDD) + 8 x 2.5-inch NVMe (SSD) max 240 TB |
||
| Power Supplies | • 600 W Platinum 100-240 VAC or 600 W 240 HVDC, hot
swap redundant
• 800 W Platinum 100-240 VAC or 800 W 240 HVDC, hot swap redundant • 1100 LVDC -48 - (-60) VDC, hot swap redundant • 1400 W Platinum 100-240 VAC or 1400 W 240 HVDC, hot swap redundant • 2400 W Platinum 100-240 VAC or 2400 W 240 HVDC, hot swap redundant • 700 W Titanium 200-240 VAC or 700 W 240 HVDC, hot swap redundant • 1100 W Titanium 100-240 VAC or 1100 W 240 HVDC, hot swap redundant • 1800 W Titanium 200-240 VAC or 1800 W 240 HVDC, hot swap redundant |
• 600 W Platinum AC/100 - 240 V
• 600 W DC/240 V • 800 W Platinum AC/100 - 240 V • 800 W DC/240 V • 1100 W Titanium AC/100 - 240 V • 1100 W DC/240 V • 1100 W DC/-48 V • 1400 W Platinum AC/100 - 240 V • 1400 W DC/240 V • 2400 W Platinum AC/100 - 240 V • 2400 W DC/240 V |
||
| Cooling Options | Air cooling | Air cooling | ||
| Fans | Standard (STD) fans or High performance (HPR) fans | Standard (STD) fans /High performance (HPR) silver fans | ||
| Up to eight hot swap fans | Up to eight hot swap fans | |||
| Dimension | Height: 464.0 mm (18.26 inches) (with feet) | Height: 464.0 mm (18.26 inches) (with feet) | ||
| 446.0 mm (17.60 inches) (without feet) | 446.0 mm (17.60 inches) (without feet) | |||
| 508.8 mm (20.03 inches) (with caster wheels) | 508.8 mm (20.03 inches) (with caster wheels) | |||
| Width — 200.0 mm (7.87 inches) | Width — 200.0 mm (7.87 inches) | |||
| Depth — 678.2 mm (26.70 inches) (with bezel) | Depth — 678.2 mm (26.70 inches) (with bezel) | |||
| 660.6 mm (26 inches) (without bezel) | 660.6 mm (26 inches) (without bezel) | |||
| Form Factor | 4.5U tower server | 4.5U tower server | ||
| Embedded Management | • iDRAC9
• iDRAC Direct • iDRAC RESTful API with Redfish • iDRAC Service Module • Quick Sync 2 wireless module |
• iDRAC9
• iDRAC Direct • iDRAC RESTful with Redfish • iDRAC Service Manual • Quick Sync 2 wireless module NOTE: iDRAC Direct and Quick Sync 2 are available only as an upsell on T550. |
||
| Bezel | Security bezel | Optional LCD bezel or security bezel | ||
| OpenManage Software | • OpenManage Enterprise
• OpenManage Power Manager plugin • OpenManage Service plugin • OpenManage Update Manager plugin • CloudIQ for PowerEdge plug in • OpenManage Enterprise Integration for VMware vCenter • OpenManage Integration for Microsoft System Center • OpenManage Integration with Windows Admin Center |
• OpenManage Enterprise
• OpenManage Power Manager plug-in • OpenManage SupportAssist plug-in • OpenManage Update Manager plug-in |
||
| Mobility | OpenManage Mobile | OpenManage Mobile | ||
| Integrations and Connections | • BMC Truesight
• Microsoft System Center • OpenManage Integration with ServiceNow • Red Hat Ansible Modules • Terraform Providers • VMware vCenter and vRealize Operations Manager |
OpenManage Integrations
• BMC TrueSight • Microsoft System Center • Red Hat Ansible Modules • VMware vCenter and vRealize Operations Manager |
OpenManage Connections
• IBM Tivoli Netcool/OMNIbus • IBM Tivoli Network Manager IP Edition • Micro Focus Operations Manager • Nagios Core • Nagios XI |
|
| Security | • Cryptographically signed firmware
• Data at Rest Encryption (SEDs with local or external key mgmt) • Secure Boot • Secured Component Verification (Hardware integrity check) • Secure Erase • Silicon Root of Trust • System Lockdown (requires iDRAC9 Enterprise or Datacenter) • TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ |
• Cryptographically signed firmware
• Secure Boot • Secure Erase • Silicon Root of Trust • System Lockdown (requires iDRAC9 Enterprise or Datacenter) • TPM 1.2/2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ |
||
| Embedded NIC | 2 x 1 GbE LOM | 2 x 1 GbE LOM | ||
| Networking Options | OCP x8 3.0 | OCP x16 Mezz 3.0 | ||
| GPU Options | Up to 2 x double-width 300 W or 6 x single-width 75 W accelerators | Up to 2 x double-width 300 W, or 5 x single-width 70 W accelerators | ||
| Ports | Front Ports
• 1 x USB 2.0 • 1 x USB 3.0 • 1 x iDRAC Direct (Micro-AB USB) port |
Rear Ports
• 1 x USB 2.0 • 1 x USB 3.0 • 1 x Serial port (optional) • 1 x Dedicated iDRAC management (RJ45) port • 2 x Ethernet ports • 1 x VGA port |
Front Ports
There are 2 SKUs:
• Base: Status LED only ○ 1 x USB 2.0 ○ 1 x USB 3.0 • Upsell: Status LED only and Quick Sync 2 ○ 1 x USB 2.0 ○ 1 x USB 3.0 ○ 1 x iDRAC Direct (Micro-AB USB) port |
Rear Ports
• 1 x USB 2.0 • 1 x iDRAC Direct ethernet port • 1 x USB 3.0 • 1 x Serial port (optioanl) • 1 x VGA |
| Internal Port : 1 x USB 3.0 (optional) | Internal Port: 1 x USB 3.0 | |||
| PCIe | Up to six PCIe slots: 4 x PCIe Gen4 slots and 2 x PCIe Gen5 slots
• Slot 1: x16 Gen5 Full height, full length • Slot 2: x16 Gen5 Full height, full length • Slot 3: x16 Gen4 Full height, half length • Slot 4: x16 Gen4 Full height, half length • Slot 5: x16 (with x8 lanes) Gen4 Full height, half length • Slot 6: x16 Gen4 Full height, half length |
3x PCIe Gen4 slots (all x16) + 1x PCIe Gen3 slot (x8) + Upsell: up to 2 PCIe x16 DW for GPU | ||
| Operating System and Hypervisors | • Canonical Ubuntu Server LTS
• Microsoft Windows Server with Hyper-V • Red Hat Enterprise Linux • SUSE Linux Enterprise Server • VMware ESXi |
• Canonical Ubuntu Server LTS
• Citrix Hypervisor • Windows Server with Hyper-V • Red Hat Enterprise Linux • SUSE Linux Enterprise Server • VMware ESXi |
||