Current Configuration

(List below serves as quick links to each section)

Select Chassis

Select Processor

Direct Liquid Cooling (DLC)

Memory

SFF SAS Drives

SFF SATA Drives

NVMe Drives

EDSFF E3.S Drives

Storage Controllers.

Fabric A./B Mezzanine Cards

Mini MX Mezzanine PCIe 4 x16 slot connects to Fabric C

Internal Boot - BOSS-N1

Security

ECS Warranty

The request has been sent.
Thank you.

Price as Configured:
$0

Error Submitting Cart. Please get in touch with us for support.

Please select all the mandatory items in the configuration list before submitting the cart.

One or more items in your cart has no price. This will be submitted as a "Request for a Quote".

Dell PowerEdge MX760c Compute Blade CTO

 

READ ME

  • Some options may not be displayed until the compatible parent option is chosen ie. Chassis – Drives, Processor – RAM etc.
  • “Quote” items can be added to your cart and sent to us via the cart page
  • Click the blue bar to close/open a section from view after choosing your options

Select Chassis

Choose a Chassis to show the supported Processors.

Select Processor

Choose a Chassis to show the supported Processors.
Supports up to 2 Processors

4-Bay & 8-E3.S Chassis - 4th Generation Intel® Xeon® Scalable Processors

Supports up to 2 Processors.
The 4x2.5" and the 8xE3.S Chassis support "Direct Liquid Cooling" (DLC)
Standard is the general Heatsink.
Liquid Cooled Processors are as follows:
8468V 8468 8480+ 8470 8470Q 8458P 6458Q

6-Bay Chassis - 4th Generation Intel® Xeon® Scalable Processors

The 6 Bay is limited in the CPUs it can support.
For more details on this please view the Tech Manual below.

Direct Liquid Cooling (DLC) (Optional)

If this option is not selected, the Air-Cooling option will be installed.
Only two Chassis can support the DLC
Please check the name and make sure you have the right one installed.
The exit port on the DLCs are different.

Memory

Supports up to 32 DIMMs on a 2-Socket configuration.

SFF SAS Drives (Optional)

Supports up to 6 SAS SSD Drives

SFF SATA Drives (Optional)

Supports up to 6 SATA SSD Drives

NVMe Drives (Optional)

Supports up to 6 NVMe SSD Drives

EDSFF E3.S Drives (Optional)

Supports up tp 8 E3.S EDSFF Drives

Storage Controllers. (Optional)

Default SW RAID, S160

Fabric A./B Mezzanine Cards (Optional)

Mezzanine slot A or B (populate A first)
Mezzanine Slot A - PCIe 4 x16 connects to the MX7000 Fabric A
Mezzanine Slot B - PCIe 5 x16 connects to the MX7000 Fabric B

Mini MX Mezzanine PCIe 4 x16 slot connects to Fabric C (Optional)

Dedicated Slot for the MX Mini Mezzanine cards
For Fabric C

Internal Boot - BOSS-N1 (Optional)

The BOSS-N1 holds up to 2 M.2 Drives.
Do not mix drives.

Security

ECS Warranty

Helpful Tip: Once desired configuration is selected click "Add to Cart".
From the cart page you can submit a submit a quote request for best pricing

Quick Specs
Form Factor:

Single Width Compute Sled

Processor | Max: 56 Cores

2 x 4th Generation Intel Xeon Scalable

Memory | Max: 8TB

32 DDR5 RDIMM 4800Mhz

Storage | Max: 92TB

8 E3.S EDSFF Gen 5 NVMe Max: 61TB
6 SFF SAS/SATA/NVMe Max: 92TB
6 SFF SAS/SATA Max: 46.08TB
4 SFF SAS/SATA Max: 61TB

Storage Controller:

S160 (SW RAID SATA/NVMe)
PERC H755 MX, H965i MX, HBA350i MX

Fabrics:

Supports a 100 Gb NIC per port for Mezz A/B

Boot Options:

BOSS-N1 (480GB or 960GB)
USB

Remote Management:

iDRAC9 with Lifecycle Controller

Ideal for:
  • Artificial Intelligence (AI)
  • Big Data Analytics
  • Virtualization
MX7000 Supported Sled Options

Each Node is a separate CTO you must configure.

High performing system:
  • Add up to two 4th generation Intel® Xeon® Scalable processors with up to 56 cores per socket for faster performance
  • Support for higher-speed and dense memory capacity, optimized for 2 DIMMs/channel and up to 32 DDR5 DIMMs 4800 MT/s
  • Storage options include increased storage density with E3.S EDSFF NVME devices/PCIe Gen5, and up to 64 E3.S devices per chassis
  • Introduction of the 100G switch with simplified common management.
A breeze to cool

Thoughtfully designed to fit in your current air-cooled infrastructure

  • Alleviate the worry about expensive liquid cooling retrofitting to your data center
  • Synchronize your workload needs with a tailored performance configuration that is an air-cooled system
  • Minimize the carbon footprint of your data center by better matching the system power consumption with anticipated workload requirements

Increase efficiency and accelerate operations with an autonomous infrastructure

The Dell OpenManage™ systems management portfolio delivers a secure, efficient, and comprehensive solution for PowerEdge servers. Simplify, automate and centralize one-to-many management with the OpenManage Enterprise console and iDRAC.

Cyber Resilient Architecture for Zero Trust IT environment & operations

Security is integrated into every phase of the PowerEdge lifecycle, including protected supply chain and factory-to-site integrity assurance. Silicon-based root of trust anchors end-to-end boot resilience while Multi-Factor Authentication (MFA) and role-based access controls ensure trusted operations.

Mezzanine & PERCs

The MX760c is different from the MX740c and the MX750c. This server does not have a JUMBO PERC. Even though a few of the PERCs seem JUMBO. They do not support the Fab C slot as well as the PERC slot. You will need to install both cards if you want access to the Expansion Storage Array MX5016s.

Image of the Mini-Mezzanine for Fab C
Mini-Mezzanine

The Mini-Mezzanine is installed in the rear of the system near the Fab A and B Mezzanine Cards. This Mini Mezzanine gets connected to the Fab C in the MX7000 Enclosure. Only certain cards are supported here.

Image of the Storage Controller
PERC

These PERCs are only supporting the Storage in this blade server. The large MX PERC do not support the MX5016s like the HBA330 and HBA350i controllers do. You are also able to install any perc with the mezzanine card for fab c.

BOOT Options

The MX760c has the option to install the OS with the BOSS Module or internal USB. If you're trying to boot the Hypervisor you can use the Internal USB.

Image of the Internal USB
Internal USB

The Internal USB is the only other way to handle Booting. This USB can handle both the main OS and the OS on the hypervisor. For iDRAC Support use one front USB 2.0 management port.

Image of the BOSS
BOSS

This Boot Optimized Sub System is ideal for loading the OS onto any server. It saves a drive from being allocated for this job and does not take up any PCIe slots. This system does not support any IDSDM.

Base Standard Capabilities

FeatureTechinal Specifications
Processor• Up to two 4th Generation Intel Xeon Scalable processors with up to 56 cores per processor
• Intel® C741 chipset with optional Intel® QuickAssist Technology
Memory32 DDR5 DIMM slot, supports RDIMM max 8 TB, speeds up to 4800 MT/s
AvailabilitySupports registered ECC DDR5 DIMMs only
Storage controllers• Internal controllers: PERC H755 MX, PERC H965i MX, HBA350i MX
• Internal boot: USB or Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 1, 2 x M.2 SSDs 480 GB or 960 GB
• Software RAID: S160
Drive BaysFront bays:
• Up to 4 x 2.5-inch SAS/SATA (HDD/SSD) max 61 TB
• Up to 6 x 2.5-inch SAS /SATA (HDD/SSD) max 46.08 TB
• Up to 6 x 2.5-inch NVMe/SAS/SATA (HDD/SSD) max 92 TB
• Up to 8 x E3.s NVMe PCIe Gen 5 SSD max 61 TB
Power SuppliesMX7000 chassis: Up to six 3000 W AC Platinum PSU and grid redundancy support
FansMX7000 chassis: 5 rear and 4 front-accessible hot-swap fans with full redundancy (Gen 2 fan required)
Dimensions• Height — 51.0 mm (2 inches)
• Width — 257.0 mm (10 inches)
• Depth — 631.77 mm (24.8 inches)
Weight8.59 kg (18.93 pound)
Form FactorUp to 8 independent hot-swappable, 1U single-width compute sled in a MX7000 chassis
Embedded ManagementMX7000 chassis: OpenManage Enterprise Modular Edition (OME-Modular);
• Up to 2 redundant MX9002m management modules
• Unified control: single management point for server, storage and networking
• Intelligent automation: Operational template methodology and comprehensive RESTful API
• Quick Sync 2 Bluetooth Low Energy (BLE) / wireless module option
On compute sled:
• iDRAC9
• iDRAC Direct
• iDRAC RESTful API with Redfish
• iDRAC Service Module
OpenManage Software• CloudIQ for PowerEdge plug in
• OpenManage Enterprise
• OpenManage Enterprise Integration for VMware vCenter
• OpenManage Integration for Microsoft System Center
• OpenManage Integration with Windows Admin Center
• OpenManage Power Manager plugin
• OpenManage Service plugin
• OpenManage Update Manager plugin
OpenManage Integrations• BMC Truesight
• Microsoft System Center
• OpenManage Integration with ServiceNow
• Red Hat Ansible Modules
• Terraform Providers
• VMware vCenter and vRealize Operations Manager
Security• Cryptographically signed firmware
• Data at Rest Encryption (SEDs with local or external key mgmt)
• Secure Boot
• Secured Component Verification (Hardware integrity check)
• Secure Erase
• Silicon Root of Trust
• System Lockdown (requires iDRAC9 Enterprise or Datacenter)
• TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ
PortsFront ports
• 1 x iDRAC Direct port (Micro-AB USB)
• 1 x USB 3.0
Internal port
• 1 x USB 3.0
Networking_Options (NDC)• MX7000 chassis Fabric options: up to 2 pairs redundant general purpose switch or passthrough modular bays (Fabrics A and B); redundant pair of storage specific switch bays (Fabric C)
• Up to 25 Gb CNA/NIC or 100 Gb NIC per port for Mezz A/B, 32 Gb Fibre Channel
PCIe• One x16 PCIe Gen4 slot for PERC - connected to processor 1
• One x16 PCIe Gen4 slot for Mezz A - connected to processor 1
• One x16 PCIe Gen5 slot for Mezz B - connected to processor 2
• One x16 PCIe Gen4 slot for Mini Mezz - connected to processor 1
• Two x8 PCIe Gen5 (SL1, SL2) connectors for NVMe drive – connected to processor 1
• Two x8 PCIe Gen5 (SL4, SL5) connectors for NVMe drive – connected to processor 2
• One x4 PCIe Gen4 for BOSS-N1 HWRAID card
Operating System and Hypervisors• Canonical Ubuntu Server LTS
• Microsoft Windows Server with Hyper-V
• Red Hat Enterprise Linux
• SUSE Linux Enterprise Server
• VMware vSAN/ESXi

Spec Sheet 4

Feature PowerEdge MX760c PowerEdge MX750c
Processor Up to two 4rd Generation Intel® Xeon® Scalable Processors
DIMM Speed: Up to 4800 MT/s
Up to 56 cores per socket
Max TDP: 350 W
Up to two 3rd Generation Intel® Xeon® Scalable Processors
DIMM Speed: Up to 3200 MT/s
Up to 40 cores per socket
Max TDP: 270 W
Chipset Intel® C741 Intel® C627A
Memory 32 DDR5 DIMM slots
32 slots for RDIMMs
Maximum capacity (RDIMM): 16 TB
32 DDR4 DIMM slots
32 slots for RDIMMs and LRDIMMs
Maximum capacity (RDIMM): 2 TB
Maximum capacity (LRDIMM): 8 TB
Intel Optane PMem 200 Series
Storage Controllers S160 Software RAID
H755 MX Performance RAID, NVMe RAID
H965i MX Performance RAID, Performance RAID, SAS/SATA or NVMe RAID
HBA350i MX
S150 Software RAID
HBA350i MX
H745P MX Performance RAID via PERC 10, internal and external drive connect, 8GB NV cache
H755 Performance RAID, NVMe RAID
HBA330 MX mini-mezz, HBA, external drive connect, no cache
Drive Support 2.5-inch 12 Gb SAS
2.5-inch NVMe 6 Gb SATA
8 x E3.S EDSFF NVMe SSD
2.5-inch 12 Gb SAS
2.5-inch 6 Gb SATA
2.5-inch NVMe
Drive Backplanes 4 x 2.5-inch SAS/SATA/NVMe (universal BP)
6 x 2.5-inch SAS/SATA
6 x 2.5-inch SATA/NVMe (universal BP)
8 x E3.S BP
6 x 2.5-inch SAS/SATA
6 x 2.5-inch SATA/NVMe (universal BP)
4 x 2.5-inch SAS/SATA/NVMe (universal BP)
Internal Boot Choice of BOSS (Boot Optimized Storage Subsystem) Choice of BOSS (Boot Optimized Storage Subsystem) or IDSDM (Internal Dual SD Module)
I/O Slots One PCIe 4.0 x16 Mezz slots (Fabric A)
One PCIe 5.0 x16 Mezz slots (Fabric B)
One PCIe 4.0 x16 Mini-mezz slot (Fabric C)
One PCIe 4.0 x16 PERC slots
One PCIe 4.0 x4 BOSS-N1
Two PCIe 4.0 x16 Mezz slots (Fabric A and B)
One PCIe 4.0 x16 Mini-mezz slot (Fabric C)
USB One internal USB 3.0 port
One front external USB 3.0 port
One front USB 2.0 management port to iDRAC
One internal USB 3.0 port
One external USB 3.0 port
One USB 2.0 management port to iDRAC
One USB 3.0 + USB 2.0 port for IDSDM
Video Integrated VGA controller in iDRAC, VGA over LAN Integrated VGA controller in iDRAC, VGA over LAN
4 Gb DDR4 shared with iDRAC application memory
Management iDRAC9 iDRAC9
Security Optional TPM 2.0
Secure Boot
Power-off security
Optional TPM 1.2/2.0
Cryptographically signed firmware
Silicon Root of Trust
Secure Boot
System Lockdown
System Erase
Fans In chassis Gen 2 fans In chassis
Power Supplies Power provided by chassis Power provided by chassis
Chassis MX7000 MX7000