Base Specs
Feature | Dell PowerVault MD3200 Series |
---|---|
Hard Disk Drives | MD3200i – Up to twelve (12) 3.5 inch SAS, Near-line SAS and SSD drives MD3220i – Up to twenty-four (24) 2.5 inch SAS, Near-line SAS and SSD drives |
3.5” Drive Performance and Capacities | 15,000 RPM SAS drives available in 300 GB, 450 GB and 600 GB 7,200 RPM Near-line SAS drives available in 500 GB, 1TB, 2TB and 3TB |
2.5” Drive Performance and Capacities | 15,000 RPM SAS drives available in 73 GB and 146 GB 10,000 RPM SAS drives available in 146 GB and 300 GB 7,200 RPM Near-line SAS drives available in 500 GB Solid State Drive (SSD) available in 149 GB (available in 3.5” HDD carriers) |
Expansion Capabilities | Expand up to a base of 120 hard drives with an optional Premium Feature Key to scale up to 192 total drives using MD1200 and/or MD1220 expansion enclosures |
Host Connectivity | |
Single Controller Models | Supports up to 4 servers directly connected or up to 32 servers when configured with an Ethernet switch |
Dual Controller Models | Supports up to 8 servers directly connected or up to 32 servers when configured with Ethernet switches |
Storage Controllers and RAID Levels | |
Storage Controllers | Each controller contains 2GB of battery-backed cache Dual controllers operate in an active-active environment mirroring each other’s cache Cache protection is provided via flash memory for permanent data protection |
RAID Levels | Support for RAID levels 0, 1, 10, 5, 6 Up to 120 physical disks per group in RAID 0, 1, 10 Up to 30 physical disks per group in RAID 5, 6 Up to 512 virtual disks |
Array Management and Optional Premium Features | |
Array Management | 2nd generation Modular Disk Storage Manager Multi-path software provides failover management of redundant data paths between the server and storage array |
Optional Premium Features | Snapshots: Up to 16 snap shots per virtual disk and 256 per system Snapshots Plus Virtual Disk Copy: Up to 16 simultaneous virtual disk copies High Performance Tier firmware upgrade increases array IO and throughput performance Additional Hard Drives - capacity up to 192 hard drives |
Back-Panel Connectors (per controller) | |
Host Connectivity | Four RJ-45 1Gb Ethernet |
Expansion Connectivity | One x4 6Gb SAS (8088 mini connector) |
Remote Management | One RJ-45 1Bb Ethernet |
Service Management | One PS/2 Serial |
LED Indicators | |
Front Panel | 1 two-color LED indicator for system status, 1 single-color LED indicator for power, 1 LED unused in this system |
Hard Drive Carrier | 1 single-color activity LED, 1 two-color LED status indicator per drive |
Storage Controller | 1 one-color LED power indicator, 1 one-color LED controller fault indicator, 1 one-color LED controller identifier, 1 one-color LED cache activity indicator, 1 one-color LED battery fault indicator |
Power Supply/Cooling Fan Module | 3 one-color LED status for AC status, DC status and power supply cooling fan fault |
Power Supplies (per supply) | |
Wattage | 600 W peak output |
Maximum Heat Dissipation | 150 W |
Input Voltage Range | 90 to 264 VAC |
Frequency Range | 47 to 63 Hz |
Maximum Input Current at Rated Power | 55 A for 10ms or less, 25 A for 10-150ms |
Available Hard Drive Power (per slot) | |
Supported Continuous Consumption | 3.5” drive: 25 Watts; 2.5” drive: 12 Watts |
Physical | |
Height x Width x Depth | MD3200: 8.68cm (3.42”) x 44.63cm (17.57”) x 56.1cm (22.09”); MD3220: 8.68cm (3.42”) x 44.63cm (17.57”) x 50.8 (20”) |
Weight | MD3200: 29.3kg (64.59 lbs.) (maximum configuration); MD3220: 24.2kg (53.35 lbs.) (maximum configuration) |
Environmental | |
Expanded Temperature Operating Range | Continuous Operation: 10C to 35C, 10% to 80% relative humidity (RH) with a 26C max dew point. De-rate maximum allowable dry bulb
temperature at 1°C/300 meters above 900 meters (1 degree F per 550 feet) 10% of annual operating hours: 5C to 40C, 5% to 85%RH with a 26C max dew point. For temperatures between 35 and 40C, de-rate maximum allowable dry bulb temperature 1°C/175 meters above 950 meters (1 degree F per 319 feet) |
Relative Humidity | 1% of annual operating hours: -5C to 45C, 5% to 90%RH, with a 26C max dew point. For temperatures between 40 and 45C, de-rate maximum allowable dry bulb temperature 1°C/125 meters above 950 meters (1 degree F per 228 feet) |
Altitude | Operating: -16 to 3048 m (-50 to 10,000 ft) Note: For altitudes above 2950 feet, the maximum operating temperature is de-rated 1°F/550 ft. |