1U rack server
Processor | Max: 4-6 Cores2 x Intel Xeon 5500 or 5600
Memory | Max: 192GB12 ECC DDR3 UDIMM/RDIMM 1333Mhz
Storage | Max: 12TB6 SFF SAS/NL-SAS/SATA (HDD/SSD)
RAID Controller:H200, H700, H800, 6Gb/s SAS HBA
NIC/LOM:Broadcom® BCM5709C 4 x iSCSI TOE
Remote Management:iDRAC6
PCIe Slots:2x PCIe 2.0 + 1 Storage Slot
GPU:None
The Dell PowerEdge R610 offers simplified management, purposeful design, and energy efficiency combined in a rack server that can help you better manage your enterprise.
Strong IT FoundationThe Dell PowerEdge R610 is a key building block for today’s data center. Designed for versatility and high performance, it provides many of the virtualization, system management, and energy efficiency features you need now and the scalability necessary to change as your business grows. This general purpose Intel processor-based 2-socket 1U server is ideal for corporate data centers and remote sites that require a dense, highly available single- or dual-processor server at an excellent value.
The PowerEdge R610 follows the 11th generation PowerEdge portfolio specifications and features the same system design commonality and reliability true to the entire portfolio. All 11th generation servers are designed to make the experience easier. We put all external ports, power supplies, LCD screens, and LED lights in the same location for familiar experience as well as easy installation and deployment.
Robust, metal hard drive carriers and organized cabling are designed to help improve component access and airflow across the server. The PowerEdge R610 provides an interactive LCD screen or LED display positioned on the front of the server for ease of monitoring and troubleshooting condition of the server.
Featuring Intel Xeon processor-based architecture, embedded hypervisors, and expanded memory footprint and I/O, the Dell PowerEdge R610 delivers exceptional overall system performance and significant virtual machine-per-server capacity versus the previous generation. With optional factory-integrated virtualization capabilities, you get tailored solutions—built with the latest technologies from Dell and our trusted partners—which allow you to streamline deployment and simplify virtual infrastructures. Choose your hypervisor from market leaders such as VMware, Citrix, and Microsoft, and enable virtualization with a few mouse clicks.
Dell’s servers offer world class system and image commonality and customer inspired usability. The Dell™ PowerEdge™ R610 takes advantage of Dell’s system commonality; When IT managers learn one system, they have learned the logic required to manage Dell’s next generation servers. The logical layout of components and power supply placement enables a simple and straight forward installation and a simplified redeployment experience in the future.
In addition, Dell’s latest PowerEdge servers provide a graphical and interactive LCD for system health monitoring, alerting and control of basic management configuration right in the front of the server. Customers have an AC power meter and ambient temperature thermometer built into the server which they can monitor on this display without any software tools.
The PowerEdge R610 has embedded Gigabit Ethernet Controllers with TCP Offload Engine (TOE) support. Two embedded Broadcom® 5709C dual-port LAN controllers are on the R610 planar as independent Gigabit Ethernet interface devices. The following information details the features of the LAN devices:
The R610 has two PCI Express risers. The two PCIe risers provide two PCI Express expansion slots, which are detailed as follows:
To ensure proper cooling, only one of the two expansion cards can have a power consumption of greater than 15W (up to 25W maximum), not including the integrated storage controller.
The system does not support hot-plug or hot-removal of PCI Express cards.
The PowerEdge R610 has a single six-drive backplane that supports 2.5” drives. There are six hotswap capable Serial Attached SCSI (SAS) or Serial ATA (SATA) slots with two LED indicators per slot, two Mini-SAS cable connectors for connecting the backplane to the integrated storage controller, and a 14-pin power connector. Mixing SAS and SATA drives is supported.
Need assistance with customization? Our sales experts are here to help you.
Start Customizing Today!
| Feature | Technical specification | |
|---|---|---|
| Form Factor | 1U rack | |
| Processors | Quad-core or six-core Intel® Xeon® processors 5500 and 5600 series | |
| Processor Sockets | 2 | |
| Front Side Bus or HyperTransport | Intel® QuickPath Interconnect (QPI) | |
| Cache | 4MB and 8MB | |
| Chipset | Intel® 5520 | |
| Memory1 | Up to 192GB (12 DIMM slots): 1GB/2GB/4GB/8GB/16GB DDR3 up to 1333MHz | |
| I/O Slots | 2 PCIe G2 slots + 1 storage slot: Two x8 slots One storage x4 slot | |
| RAID Controller | Internal: PERC H200 (6Gb/s) PERC H700 (6Gb/s) with 512MB battery-backed cache; 512MB, 1GB Non-Volatile battery-backed cache SAS 6/iR PERC 6/i with 256MB battery-backed cache | External: PERC H800 (6Gb/s) with 512MB of battery-backed cache; 512MB, 1GB Non-Volatile battery-backed cache PERC 6/E with 256MB or 512MB of battery-backed cache External HBAs (non-RAID): 6Gbps SAS HBA SAS 5/E HBA LSI2032 PCIe SCSI HBA |
| Drive Bays | Internal hard drive bay and hot-plug backplane. Up to six 2.5” SAS, or SSD Drives | |
| Maximum Internal Storage | Up to 12TB | |
| Hard Drives1 | Hot-plug Hard Drive Options: 2.5” SAS SSD, SATA SSD, SAS (10K, 15K), nearline SAS (7.2K), SATA (7.2K) | |
| Communications | Two dual port embedded Broadcom NetXtreme II 5709c Gigabit Ethernet NIC with failover and load balancing. Optional 1GBe and 10GBe add-in NICs Broadcom® NetXtreme® II 57711 Dual Port Direct Attach 10Gb Ethernet PCI-Express Network Interface Card with TOE and iSCSI Offload Intel® Gigabit ET Dual Port Server Adapter and Intel® Gigabit ET Quad Port Server Adapter Dual Port 10GB Enhanced Intel Ethernet Server Adapter X520-DA2 (FCoE Ready for Future Enablement) Brocade® CNA Dual-port adapter Emulex® CNA iSCSI HBA stand up adapter OCE10102-IX-D Emulex® OCE10102-IX-DCNA iSCSI HBA stand-up adapter Optional Add-In HBA’s: Brocade® 8 GB HBAs | |
| Power Supply | Two hot-plug high-efficient 502W Energy Smart PSU or two hot-plug 717W High Output PSUs Uninterruptible Power Supplies: 1000W-5600W 2700W-5600W High Efficiency Online Extended Battery Module (EBM) Network Management Card | |
| Availability | DDR3 memory; ECC; hot-plug hard drives; optional hot-plug redundant power supplies; dual embedded NICs with failover and load balancing support; optional PERC6/i integrated daughtercard controller with battery-backed cache; hotplug redundant cooling; tool-less chassis; fibre and SAS cluster support; validated for Dell/EMC SAN | |
| Video | Integrated Matrox® G200, 8MB shared video memory | |
| Remote Management | iDRAC6 Enterprise (optional) | |
| Systems Management | Dell™ OpenManage™ | |
| Embedded Hypervisor | Optional Embedded SD Media | |
| Rack Support | ReadyRails™ sliding rails with optional cable management arm for 4-post racks (optional adapter brackets required for threaded hole racks); ReadyRails™ static rails for 2-post and 4-post racks | |
| Operating Systems | Microsoft® Windows® Small Business Server 2011 Microsoft® Windows® Small Business Server 2008 Microsoft® Windows Server® 2008 SP2, x86/x64 (x64 includes Hyper-V™) Microsoft® Windows Server® 2008 R2, x64 (includes Hyper-V™ v2) Microsoft® Windows® HPC Server 2008 R2 Novell® SUSE® Linux® Enterprise Server Red Hat® Enterprise Linux® Oracle® Solaris™ Virtualization Options: Citrix® XenServer™ VMware® vSphere™ 4.1 (including VMware ESX® 4.1 or VMware ESXi™ 4.1) For more information on the specific versions and additions, visit www.dell.com/OSsupport. | |
| Featured Database Applications | Microsoft SQL Server solutions (see Dell.com/SQL) Oracle® database solutions (see Dell.com/Oracle) | |
| Feature | R510 | R610 | R710 |
|---|---|---|---|
| Processor | Intel® Xeon® processor 5500 and 5600 series | Intel® Xeon® processor 5500 and 5600 series | Intel® Xeon® processor 5500 and 5600 series |
| Form Factor | 2U rack | 1U rack | 2U rack |
| Front Side Bus | Intel® QuickPath Interconnect (QPI) 6.4GT/s |
Intel® QuickPath Interconnect (QPI) 6.4GT/s |
Intel® QuickPath Interconnect (QPI) 6.4GT/s |
| # Sockets | 2 | 2 | 2 |
| # Cores | 2, 4, or 6 | 2, 4, or 6 | 2, 4, or 6 |
| L2/L3 Cache | 4MB, 8MB, and 12BM | 4MB, 8MB, and 12BM | 4MB, 8MB, and 12BM |
| Chipset | Intel® 5500 | Intel® 5520 | Intel® 5520 |
| DIMMs | 8 DDR3 | 12 DDR3 | 18 DDR3 |
| Min/Max RAM | 1GB/128GB | 1GB/192GB | 1GB/288GB |
| Drive Bays | 4 x 3.5”, or 8 x 3.5” or 2.5”, or 12 x 3.5” or 2.5” + 2 x internal 2.5” |
6 x 2.5” | 4 x 3.5" with optional flex bay, 6 x 3.5" without flex bay, or 8 x 2.5” |
| Hard Drive Types | SAS, SATA, and SSD | Hot-plug SAS and SATA, nearline SAS and SSD | Hot-plug SAS and SATA, nearline SAS and SSD |
| External Drive Bay(s) | Four- and eight-drive chassis: optional internal SATA slimline optical drives such as DVD-ROM or DVD+RW Twelve-drive chassis: N/A | Optional internal SATA slimline optical drives such as DVD-ROM or DVD+RW | Optional flex bay expansion to support half-height tape backup unit |
| Embedded Hard Drive Controller | PERC 6/i, SAS 6/iR, PERC H200, PERC H700, PERC S100, PERC S300 | PERC 6/i, SAS 6/iR, PERC H200, PERC H700 | PERC 6/i, SAS 6/iR, PERC H200, PERC H700 |
| Optional Storage Controller | Non-RAID: SAS 5/E LSI 2032 (for tape backup unit only) 6Gps SAS HBA RAID: SAS 6/iR PERC 6/i PERC 6/E PERC H200 PERC H700 PERC H800 Software RAID: PERC S100 (4-drive chassis only) PERC S300 (4- and 8- drive chassis only) |
Non-RAID: SAS 5/E LSI 2032 (for tape backup unit only) 6Gps SAS HBA RAID: SAS 6/iR PERC 6/i PERC 6/E PERC H200 PERC H700 PERC H800 |
Non-RAID: SAS 5/E LSI 2032 (for tape backup unit only) 6Gps SAS HBA RAID: SAS 6/iR PERC 6/i PERC 6/E PERC H200 PERC H700 PERC H800 |
| Availability | Hot-plug hard drives, redundant power, quad-pack LED diagnostic or LCD (with hot-plug hard drive chassis), memory mirroring | Hot-plug hard drives, hot-plug redundant power and cooling, ECC memory, Single Device Data Correction (SDDC), memory demand and patrol scrubbing, high-availability failover cluster | Hot-plug hard drives, hot-plug redundant power and cooling, ECC memory, Single Device Data Correction (SDDC), memory demand and patrol scrubbing, high-availability failover cluster |
| Server Management | BMC, IPMI 2.0, Dell OpenManage™ Optional: iDRAC6 Express, iDRAC 6 Enterprise, vFlash | iDRAC6 Express, BMC, IPMI 2.0, Dell OpenManage™ Optional: iDRAC6 Enterprise, vFlash | iDRAC6 Express, BMC, IPMI 2.0, Dell OpenManage™ Optional: iDRAC6 Enterprise, vFlash |
| I/O Slots | 3 PCIe + 1 storage slot or 1 PCIe + 1 storage slot |
2 PCIe x8 G2 | 2 PCIe x8 + 2 PCIe x4 G2
or 1 x PCIe x16 + 2 PCIe x4 G2 |
| RAID | SAS 6/iR and PERC H200: RAID 0, 1 PERC 6/i and PERC H700: RAID 0, 1, 5, 6, 10, 50, 60 PERC S100: 0, 1, 5, 10 PERC S300: 0, 1, 5, 10 |
SAS 6/iR and PERC H200: RAID 0, 1 PERC 6/i and PERC H700: RAID 0, 1, 5, 6, 10, 50, 60 |
SAS 6/iR and PERC H200: RAID 0, 1 PERC 6/i and PERC H700: RAID 0, 1, 5, 6, 10, 50, 60 |
| NIC/LOM | Broadcom® BCM5716
2 x iSCSI TOE Optional: various NICs available |
Broadcom® BCM5709C
4 x iSCSI TOE Optional: various NICs available |
Broadcom® BCM5709C
4 x iSCSI TOE Optional: various NICs available |
| USB | 2 front, 2 back, 2 internal | 2 front, 2 back, 1 internal | 2 front, 2 back, 1 internal |
| Power Supplies | Four-drive chassis: non-redundant, 480W Eight-drive and twelvedrive chassis: hot-plug redundant 750W | Two redundant hot-plug high efficiency 502W or two redundant hot-plug high output 717W | Two redundant hot-plug high efficiency 570W or two redundant hot-plug high output 870W |
| Fans | Four-drive chassis: four non-redundant, non-hotpluggable fans Eight-drive chassis: five non-redundant, non-hotpluggable fans Twelve-drive chassis: five redundant, non-hotpluggable, dual-rotor fans |
Six dual-rotor fans (dual processor configuration) or five dual-rotor fans (single processor configuration) |
Five hot-plug fans (default processor configuration) or four hot-plug fans (single processor configuration) |