Storage Limits
Max # of Drives (Total) | Max # of Internal Drives | Max # of MSATA Drives | Max # of NL-SAS Drives | Max # of SAS Drives | Max # of SATA Drives | Max # of SSD Drives | Max # of DS212C Shelves | Max # of DS2246 Shelves | Max # of DS224C Shelves | Max # of DS4243 Shelves | Max # of DS4246 Shelves | Max # of DS4486 Shelves | Max # of DS460C Shelves |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Supported Shelves/Drives | 720 | N/A | 720 | 720 | 720 | 720 | 480 | 60 external | 30 external | 30 external | N/A | 30 external | 30 external |
Capacity Limits
Marketing Max Raw Capacity - Node | HA Pair | Cluster | Effective Capacity - Node | HA Pair | Cluster |
---|---|---|---|---|---|
11520000 | 11520000 | N/A | 51131520 | 51131520 | N/A |
Core Cluster Limits
Max SVM's | Max LIF's - NAS | Max Connections - NAS | Max Flexible Volumes - NAS | Max Lock Manager Locked Objects | Max Intercluster LIFs - Node | Min Root Aggregate (MiB) - Node | Min Root Volume (GiB) - Node | Max IPsec Policies | Max Auditing-Enabled SVMs - Cluster |
---|---|---|---|---|---|---|---|---|---|
Node:N/A HA Pair:N/A Cluster:1024 | Node:512 HA Pair:512 Cluster:3072 | Node:100000 HA Pair(Non-Scalable):100000 | Aggregate (Single data Agg. per Node):Detailed Matrix Aggregate (Multiple data Agg. per Node):N/A Node:N/A HA Pair:1000 Cluster:2000 | Node:1200000 HA Pair:1200000 Cluster:12288000 | 8 | 191488 | 150 | SVM:256 Cluster:1500 | 50 |
System Maximums and Limits
Max Nodes per Cluster (NAS / SAN) | Max FabricPool Size | Max Infinite Volume Data Constituent Size | Max FlexGroup Data Constituent Size | Min Root Volume Size | NetApp Volume Encryption |
---|---|---|---|---|---|
24 / 12 | 16800 TiB | Not Supported | 100 TiB | 150 GiB [1] | Supported |
Processor
Processor Model | Processor Architecture | Processor Speed | Processor Count (Per Node) | Processor Count (Per Config) | Processor Cores (Per CPU) | Processor Cores (Per Node) | Processor Cores (Per Config) |
---|---|---|---|---|---|---|---|
64-bit 10-core 2.20 Ghz | 64 bit | 2.20 Ghz | 2 | 4 | 10 | 20 | 40 |
Memory
NVME (Per Node) | NVME (Per Config) | NVMEM (Per Node) | NVMEM (Per Config) | RAM (Per Node) | RAM (Per Config) |
---|---|---|---|---|---|
16 GB | 32 GB | 128 GB | N/A | N/A | 256 GB |
Onboard Ports
Ethernet Ports | Fibre Channel | Ports UTA2 Ports | Expansion Slots | SAS Ports |
---|---|---|---|---|
4 x QSFP28 (40Gb) / 8 x SFP28 (25Gb) | - | Not Supported | 4 x M.2 PCIe, 10 x PCIe3 | 8 x MiniSAS HD (12Gb) |
Physical Characteristics
Rack Units | Chassis Height | Chassis Width with Mounting Flanges | Chassis Width without Mounting Flanges | Chassis Depth with Cable Mgmt | Chassis Depth without Cable Mgmt | Chassis Weight |
---|---|---|---|---|---|---|
4 | 6.89" (17.5 cm) | 19.02" (48.3 cm) | 17.6" (44.7 cm) | 34.72" (88.2 cm) | 32.6" (82.8 cm) | See Weights by configuration |
System Clearance Dimensions
Front Clearance (Cooling) | Front Clearance (Maintenance) | Rear Clearance (Cooling) | Rear Clearance (Maintenance) |
---|---|---|---|
6.03" (15.3 cm) | 34.51" (87.6 cm) | 6.03" (15.3 cm) | 36.01" (91.4 cm) |
Environmental Requirements
Operating | Storage | Transit | Acoustic Noise | Input Power Voltage |
---|---|---|---|---|
Tempature: 50 to 95 deg F - 10 to 35 deg C Humidity: 8 to 80 % Altitude: Up to 10000.0 ft - Up to 3048.0 m | Tempature: -40 to 158 deg F - -40 to 70 deg C Humidity: 10 to 95 % Altitude: Up to 40000.0 ft - Up to 12192.0 m | Tempature: -40 to 158 deg F - -40 to 70 deg C Humidity: 10 to 95 % Altitude: Up to 39989.8 ft - Up to 12192 m | Sound Power: 8.5 bels Sound Pressure: 67.2 dBA | 100 to 120 200 to 240 |
Storage OS Requirements
Full OS Matrix | Recommended Version | Minimum OS | Maximum OS |
---|---|---|---|
View Full OS Report Below | 9.11.1 | 9.11.1RC1 | 9.11.1 |
Storage and Firmware
Full Firmware Matrix | BIOS | BMC |
---|---|---|
Full Firmware Report Below | 13.6P1 | - |
Product Standards Compliance
Full Compliance and Certificates Report | Cert. EMC/EMI | Cert. Safety | Cert. Safety/EMC/EMI | Cert. Safety/EMC/EMI/RoHS | Standard Safety/EMC/EMI | Standard Safety |
---|---|---|---|---|---|---|
Compliance and Certificates Report Below | AMCA, FCC, ICES, KC, Morocco, VCCI | BIS, CB, CSA, G_K_U-SoR, IRAM, NOM, NRCS, SONCAP, TBS | EAC, UKRSEPRO | BSMI, CE DoC, UKCA DoC | BS-EN-55024, BS-EN55035, CISPR 32, EN55022, EN55024, EN55032, EN55035, EN61000-3-2, EN61000-3-3, FCC Part 15 Class A, IC more... | ANSI/UL60950-1, ANSI/UL62368-1, BS-EN62368-1, CAN/CSA C22.2 No. 60950-1, CAN/CSA C22.2 No. 62368-1, CNS 14336, EN60825-1 more... |
NFS Cluster Limits
Max Export Policies - Cluster | Max Export Rules - Cluster | Max NFSv4 Access Control Entries | Max Client Objects | Max pNFS objects |
---|---|---|---|---|
24000 | 200000 | 1024 | Node:100000 HA Pair:100000 | Node:1024000 HA Pair:1024000 Cluster:12288000 |
WAFL Cluster Limits - All Maximums
Size 64-bit Aggregate (TiB) | Size 64-bit Volume (TiB) | File size 64-bit Volume (TiB) | Volume Snapshot Copies | Character length for Snapshot copy names | Hard links - File | inodes/files - Volume | Number of qtrees | Concurrent DataMotion for Volumes ops |
---|---|---|---|---|---|---|---|---|
800 | 100 | 16 | Volume:1023 Node:1023000 HA Pair:2046000 | 255 | 100000 | 2000000000 | Volume:4995 Node:100000 HA Pair:200000 Cluster:2400000 | Node:16 HA Pair:16 |
Quality of Service Cluster Limits
Max Policy Groups - Cluster | Max QoS User Workloads - Cluster |
---|---|
12000 | 40000 |
SAN Cluster Limits - All Maximums
# of storage virtual machines (SVMs) - SAN | # of flexible volumes - SAN | # of Flexible Vol with DPO - | # of LUNs | LUN mappings | LUN size (TiB) - LUN | FC queue depth available | # of SAN Hosts (ITNs) | # of LIFS - iSCSI | # of LIFS - FCP | # of igroups | # of Initiators | # of Portsets | # of iSCSI sessions |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Node:125 HA Pair:250 Cluster:1000 | Single data Aggregate:N/A Multiple data Aggregates:N/A Node:1000 HA Pair:2000 Cluster:12000 | Node:2500 HA Pair:5000 Cluster:12000 | Valume:1024 Node:12288 HA Pair:24576 Cluster:98304 | Node:12288 HA Pair:24576 Cluster:98304 | 16 | 2048 | Port:512 Node:8192 HA Pair:16384 Cluster:65536 | Port:32 Portset:32 Node:512 HA Pair:1024 Cluster:4096 | Port:32 Portset:32 Node:512 HA Pair:1024 Cluster:4096 | Node:4096 HA Pair:8192 Cluster:32768 | igroup:256 Node:4096 HA Pair:8192 Cluster:32768 | Node:4096 HA Pair:8192 Cluster:32768 | Node:8192 HA Pair:16384 Cluster:65536 |
CIFS Cluster Limits - All Maximums
# of Connected Shares | # of Regular Shares | # of Open files | # of Local users - Cluster | # of Local groups - Cluster | # of Local group members - Cluster |
---|---|---|---|---|---|
Node:1000000 HA Pair:1000000 | Node:N/A HA Pair:N/A Cluster:300000 | Connection:65536 Node:1500000 HA Pair:1500000 | 35000 | 320000 | 640000 |
Data Protection Cluster Limits - All Maximums
NDMP Sessions | Data Protection Mirrors | Load Sharing Mirrors - NAS SVM | Concurrent Snap Mirror / SnapVault transfers - Node | DP Mirror fan-out - Volume | LS Mirror fan-out - NAS SVM | # of Clusters that can be peered - Cluster | Volumes, SnapMirror relationship | SnapMirror Synchronous relationships | Flexible Volumes in SVM DR | SVM Disaster recovery - Cluster |
---|---|---|---|---|---|---|---|---|---|---|
Node:36 HA Pair (Non-Scalable):36 | Volume:1 Node:1000 HA Pair:2000 Cluster:15000 | 2 | 100 | 8 | 2 | 255 | FlexGroup:200 FlexGroup-Node:50 HA Pair:1000 Cluster:6000 | Volume:1 Node:40 HA Pair (Non-Scalable):40 | SVM:300 HA Pair:1000 | 128 |
NVMe/oF Cluster Limits - All Maximums
# of Storage virtual machines (SVMs), NVMe/oF - Cluster | # of Flexible volumes, NVMe/oF | # of Flexible volumes with DPO, NVMe/oF | # of Namespaces | # of Subsystems | # of Namespace Mappings | Namespace Size | I/O queue depth available - NVMe/FC - Queue | I/O queue count available - NVMe/FC - Controller | Hosts - Subsystem | LIFS, NVMe/oF | # of Controllers - NVMe/FC - Port | I/O Queue Count, NVMe/TCP - Controller | I/O Queue Depth - NVMe/TCP | Controllers, NVMe/TCP - Node |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
32 | Node:1000 HA Pair:2000 Cluster:12000 | Node:2500 HA Pair:5000 Cluster:12000 | Volume:1024 Node:12288 HA Pair:24576 Cluster:98304 | Node:512 Node:512 | Subsystem:1024 Node:12288 HA Pair:24576 Cluster:98304 | 16 | N/A | N/A | 64 | | N/A | 2 | 128 | 1024 |
FlexCache Cluster Limits - All Maximums Cache
Degree of fan-out - Origin | Origin Volumes | Constituent Volumes | Volumes | Origin ConstituentVolumes |
---|---|---|---|---|
100 | Node:100 HA Pair:200 | Node:800 HA Pair:1600 | Node:100 HA Pair:200 | Node:800 HA Pair:1600 |
S3 Cluster Limits -
Max # of Buckets | Max # of Objects - Bucket | Max # of Users | Max Size of the Bucket (PB) - Vserver |
---|---|---|---|
Vserver:12000 Cluster:12000 | 400000000000 | Vserver:4000 Cluster:96000 | 20 |
Consistency Groups - All Maximums
Number of Consistency Groups - Cluster | Consistency Groups and Parents Consistency Groups - Cluster | Number of Parent Consistency Groups - Cluster | Child Consistency Groups in a Parent Consistency Groups - Parent Group | Flexible Volumes in a Consistency Group | Flexible Volumes for Child Consistency Groups under a Parent Group | Flexible Volumes in a Child Consistency Group |
---|---|---|---|---|---|---|
15000 | 15000 | 15000 | 5 | 80 | 80 | 80 |
Platform LED for FAS8300 Single Chassis HA Pair, Ethernet Bundle
LED Label | LED Name | Type | Status Indicator | Description | |||||
---|---|---|---|---|---|---|---|---|---|
Back View | |||||||||
LED Label | LED Name | Type | Status Indicator | Description | |||||
0a | Link is Established - Green No link - off Port requires attention - Amber Port operates as normal- off | Attention | Amber | Port requires attention | |||||
- | - | - | Off | Port operates as Normal | |||||
- | - | Link | Green | Link is established | |||||
- | - | - | Off | No link | |||||
0b | Link is Established - Green No link - off Port requires attention - Amber Port operates as normal- off | Attention | Amber | Port requires attention | |||||
- | - | - | Off | Port operates as Normal | |||||
- | - | Link | Green | Link is established | |||||
- | - | - | Off | No link | |||||
0c | Link is Established - Green No link - off Port requires attention - Amber Port operates as normal- off | Attention | Amber | Port requires attention | |||||
- | - | - | Off | Port operates as Normal | |||||
- | - | Link | Green | Link is established | |||||
- | - | - | Off | No link | |||||
0d | Link is Established - Green No link - off Port requires attention - Amber Port operates as normal- off | Attention | Amber | Port requires attention | |||||
- | - | - | Off | Port operates as Normal | |||||
- | - | Link | Green | Link is established | |||||
- | - | - | Off | No link | |||||
e0a | Port Ethernet SFP Config | Attention | Yellow | Ethernet Port requires attention. | |||||
- | - | - | Off | Ethernet port operates as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0b | Port Ethernet SFP Config | Attention | Yellow | Ethernet Port requires attention. | |||||
- | - | - | Off | Ethernet port operates as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0c | Port Ethernet QSFP Link/Attention | Attention | Amber | Ethernet Port requires attention. | |||||
- | - | - | Off | Ethernet port operates as normal | |||||
- | - | Link | Green | Link is established | |||||
- | - | - | Off | No link | |||||
e0d | Port Ethernet QSFP Link/Attention | Attention | Amber | Ethernet Port requires attention. | |||||
- | - | - | Off | Ethernet port operates as normal | |||||
- | - | Link | Green | Link is established | |||||
- | - | - | Off | No link | |||||
e0e | Port Ethernet SFP Config | Attention | Yellow | Ethernet Port requires attention. | |||||
- | - | - | Off | Ethernet port operates as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0f | Port Ethernet SFP Config | Attention | Yellow | Ethernet Port requires attention. | |||||
- | - | - | Off | Ethernet port operates as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0g | Port Ethernet SFP Config | Attention | Yellow | Ethernet Port requires attention. | |||||
- | - | - | Off | Ethernet port operates as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0h | Port Ethernet SFP Config | Attention | Yellow | Ethernet Port requires attention. | |||||
- | - | - | Off | Ethernet port operates as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0m/BMC | Port Remote Management Config | - | Blinking amber | Traffic is flowing over the connection. | |||||
- | - | - | Green | A link is established between the port and some upstream device. | |||||
- | - | - | Off | No link is established. |
Supported Shelves Drives for FAS8300 Single Chassis HA Pair, Ethernet Bundle
Part No. | Capacity | RPM | Drive Type | Encryption | Root-Data Partitioning | Root-Data-Data Partitioning | Storage Pool Partitioning | Max Drive Count | FlexArray |
---|---|---|---|---|---|---|---|---|---|
DS212C with IOM12B / IOM12 / IOM12 / IOM12B shelf modules | |||||||||
X302A-R5 | 1TB | 7.2K | SATA | No | Yes | No | No | 720 | No |
X306A-R5 | 2TB | 7.2K | SATA | No | Yes | No | No | 720 | No |
X308A-R5 | 3TB | 7.2K | SATA | No | Yes | No | No | 720 | No |
X315A-R6 [1] | 4TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X317A [1] | 6TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X318A-R6 | 8TB | 7.2K | NL-SAS | No | Yes | No | No | 720 | No |
X322A [1] | 10TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X336A-R6 | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 720 | No |
X339A | 2TB | 7.2K | NL-SAS | No | Yes | No | No | 720 | No |
X380A | 10TB | 7.2K | NL-SAS | No | Yes | No | No | 720 | No |
X388A | 16TB | 7.2K | NL-SAS | No | Yes | No | No | 720 | No |
X477A-R6 | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 720 | No |
X488A-R5 | 900GB | 10K | SAS | No | Yes | No | No | 720 | No |
X489A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 720 | No |
X490A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 720 | No |
X363A-R6 | 3.84TB | N/A | SSD | No | No | No | Yes | 480 | No |
X364A | 3.84TB | N/A | SSD | No | No | No | Yes | 480 | No |
X366A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 480 | No |
X374A | 960GB | N/A | SSD | No | No | No | Yes | 480 | No |
X448A-R6 | 200GB | N/A | SSD | No | No | No | Yes | 480 | No |
X449A-R6 | 800GB | N/A | SSD | No | No | No | Yes | 480 | No |
X575A-R6 | 400GB | N/A | SSD | No | No | No | Yes | 480 | No |
X576A-R6 | 1.6TB | N/A | SSD | No | No | No | Yes | 480 | No |
DS224C with IOM12 / IOM12B / IOM12 / IOM12B shelf modules | |||||||||
X341A-R6 | 900GB | 10K | SAS | No | Yes | No | No | 720 | No |
X342A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 720 | No |
X343A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 720 | No |
X416A-R5 [1] | 600GB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X417A-R6 [1] | 900GB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X421A-R5 | 450GB | 10K | SAS | No | Yes | No | No | 720 | No |
X422A-R5 | 600GB | 10K | SAS | No | Yes | No | No | 720 | No |
X423A-R5 | 900GB | 10K | SAS | No | Yes | No | No | 720 | No |
X425A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 720 | No |
X426A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 720 | No |
X427A [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X427B-R6 [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X319A | 7.6TB | N/A | SSD | No | No | Yes | No | 480 | No |
X356A-R6 | 3.84TB | N/A | SSD | No | No | Yes | Yes | 480 | No |
X357A | 3.84TB | N/A | SSD | No | No | Yes | Yes | 480 | No |
X358A [1] | 3.84TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 480 | No |
X359A | 30.6TB | N/A | SSD | No | No | Yes | No | 480 | No |
X365A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 480 | No |
X371A | 960GB | N/A | SSD | No | No | Yes | Yes | 480 | No |
X386A [1] | 960GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 480 | No |
X438A-R6 | 400GB | N/A | SSD | No | No | Yes | Yes | 480 | No |
X439A-R6 | 1.6TB | N/A | SSD | No | No | Yes | Yes | 480 | No |
X440A-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 480 | No |
X440B-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 480 | No |
X446A-R6 | 200GB | N/A | SSD | No | No | No | Yes | 480 | No |
X446B-R6 | 200GB | N/A | SSD | No | No | No | Yes | 480 | No |
X447A-R6 | 800GB | N/A | SSD | No | No | Yes | Yes | 480 | No |
X670A | 15.3TB | N/A | SSD | No | No | Yes | No | 480 | No |
DS460C with IOM12 / IOM12B / IOM12B / IOM12 shelf modules | |||||||||
X375A | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 720 | No |
X376A | 8TB | 7.2K | NL-SAS | No | Yes | No | No | 720 | No |
X377A | 10TB | 7.2K | NL-SAS | No | Yes | No | No | 720 | No |
X378A [1] | 10TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X379A | 960GB | N/A | SSD | No | No | No | No | 120 | No |
X387A | 16TB | 7.2K | NL-SAS | No | Yes | No | No | 720 | No |
DS2246 with IOM6 / IOM12B / IOM12 / IOM6 / IOM12 / IOM12B shelf modules | |||||||||
X341A-R6 | 900GB | 10K | SAS | No | Yes | No | No | 720 | No |
X342A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 720 | No |
X343A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 720 | No |
X416A-R5 [1] | 600GB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X417A-R6 [1] | 900GB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X421A-R5 | 450GB | 10K | SAS | No | Yes | No | No | 720 | No |
X422A-R5 | 600GB | 10K | SAS | No | Yes | No | No | 720 | No |
X423A-R5 | 900GB | 10K | SAS | No | Yes | No | No | 720 | No |
X425A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 720 | No |
X426A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 720 | No |
X427A [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X427B-R6 [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X356A-R6 | 3.84TB | N/A | SSD | No | No | Yes | Yes | 480 | No |
X357A | 3.84TB | N/A | SSD | No | No | Yes | Yes | 480 | No |
X358A [1] | 3.84TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 480 | No |
X365A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 480 | No |
X371A | 960GB | N/A | SSD | No | No | Yes | Yes | 480 | No |
X438A-R6 | 400GB | N/A | SSD | No | No | Yes | Yes | 480 | No |
X439A-R6 | 1.6TB | N/A | SSD | No | No | Yes | Yes | 480 | No |
X440A-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 480 | No |
X440B-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 480 | No |
X446A-R6 | 200GB | N/A | SSD | No | No | No | Yes | 480 | No |
X446B-R6 | 200GB | N/A | SSD | No | No | No | Yes | 480 | No |
X447A-R6 | 800GB | N/A | SSD | No | No | Yes | Yes | 480 | No |
DS4246 with IOM6 / IOM12 / IOM12 / IOM12B / IOM12B / IOM6 shelf modules | |||||||||
X302A-R5 | 1TB | 7.2K | SATA | No | Yes | No | No | 720 | No |
X306A-R5 | 2TB | 7.2K | SATA | No | Yes | No | No | 720 | No |
X308A-R5 | 3TB | 7.2K | SATA | No | Yes | No | No | 720 | No |
X309A-R6 [1] | 3TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X315A-R6 [1] | 4TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X316A-R6 | 6TB | 7.2K | NL-SAS | No | Yes | No | No | 720 | No |
X317A [1] | 6TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X318A-R6 | 8TB | 7.2K | NL-SAS | No | Yes | No | No | 720 | No |
X322A [1] | 10TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 720 | No |
X336A-R6 | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 720 | No |
X380A | 10TB | 7.2K | NL-SAS | No | Yes | No | No | 720 | No |
X477A-R6 | 4TB | 7.2K | NL-SAS | No | Yes | No | No | 720 | No |
X488A-R5 | 900GB | 10K | SAS | No | Yes | No | No | 720 | No |
X489A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 720 | No |
X490A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 720 | No |
X363A-R6 | 3.84TB | N/A | SSD | No | No | No | Yes | 480 | No |
X366A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 480 | No |
X374A | 960GB | N/A | SSD | No | No | No | Yes | 480 | No |
X441A-R5 | 100GB | N/A | SSD | No | No | No | No | 480 | No |
X442A-R5 [2] | 100GB | N/A | SSD | No | No | No | No | 480 | No |
X448A-R6 | 200GB | N/A | SSD | No | No | No | Yes | 480 | No |
X449A-R6 | 800GB | N/A | SSD | No | No | No | Yes | 480 | No |
X575A-R6 | 400GB | N/A | SSD | No | No | No | Yes | 480 | No |
X576A-R6 | 1.6TB | N/A | SSD | No | No | No | Yes | 480 | No |
X577A-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 480 | No |
DS4486 with IOM6 shelf modules | |||||||||
X381A | 10TB | 7.2K | MSATA | No | No | No | No | 720 | No |
X478A-R5 | 3TB | 7.2K | MSATA | No | No | No | No | 720 | No |
X480A-R6 | 4TB | 7.2K | MSATA | No | No | No | No | 720 | No |
X481A-R6 | 6TB | 7.2K | MSATA | No | No | No | No | 720 | No |
X483A-R6 | 8TB | 7.2K | MSATA | No | No | No | No | 720 | No |
Footnote: | |||||||||
[1] Mixing NSE drives or shelves with any other type of encrypting or non-encrypting drives or shelves across a stand-alone platform or high-availability (HA) pair is not supported. | |||||||||
[2] This drive does not support the sanitization feature. |
Supported RAID Configurations - FAS8300 Single Chassis HA Pair, Ethernet Bundle
Drive Type | Drive Capacity Min | Drive Capacity Max | Minimum | Default | Maximum | ||||
---|---|---|---|---|---|---|---|---|---|
Data Aggregate | |||||||||
RAID4 | |||||||||
NL-SAS | 0 TB | 8 TB | 3 | 7 | 7 | ||||
SAS | 0 TB | 5.999 TB | 3 | 8 | 14 | ||||
SATA | 0 TB | 5.999 TB | 3 | 7 | 7 | ||||
SSD | 0 TB | 30.6 TB | 3 | 8 | 14 | ||||
RAID-DP | |||||||||
MSATA | 0 TB | 5.999 TB | 5 | 14 | 20 | ||||
MSATA | 6 TB | 8 TB | 5 | 14 | 14 | ||||
NL-SAS | 0 TB | 5.999 TB | 5 | 14 | 20 | ||||
NL-SAS | 6 TB | 10 TB | 5 | 14 | 14 | ||||
SAS | 0 TB | 5.999 TB | 5 | 16 | 28 | ||||
SATA | 0 TB | 5.999 TB | 5 | 14 | 20 | ||||
SSD | 0 TB | 30.6 TB | 5 | 24 | 28 | ||||
RAID-TEC | |||||||||
MSATA | 0 TB | 10 TB | 7 | 21 | 29 | ||||
NL-SAS | 0 TB | 16 TB | 7 | 21 | 29 | ||||
SAS | 0 TB | 8 TB | 7 | 24 | 29 | ||||
SATA | 0 TB | 8 TB | 7 | 21 | 29 | ||||
SSD | 0 TB | 30.6 TB | 7 | 25 | 29 | ||||
Root Aggregate | |||||||||
RAID4 | |||||||||
NL-SAS | 0 TB | 8 TB | 2 | - | 7 | ||||
SAS | 0 TB | 5.999 TB | 2 | - | 14 | ||||
SATA | 0 TB | 5.999 TB | 2 | - | 7 | ||||
SSD | 0 TB | 30.6 TB | 2 | - | 14 | ||||
RAID-DP | |||||||||
MSATA | 0 TB | 5.999 TB | 3 | - | 20 | ||||
MSATA | 6 TB | 8 TB | 3 | - | 14 | ||||
NL-SAS | 0 TB | 5.999 TB | 3 | - | 20 | ||||
NL-SAS | 6 TB | 16 TB | 3 | - | 14 | ||||
SAS | 0 TB | 5.999 TB | 3 | - | 28 | ||||
SATA | 0 TB | 5.999 TB | 3 | - | 20 | ||||
SSD | 0 TB | 30.6 TB | 3 | - | 28 | ||||
RAID-TEC | |||||||||
MSATA | 0 TB | 10 TB | 7 | - | 29 | ||||
NL-SAS | 0 TB | 16 TB | 7 | - | 29 | ||||
SAS | 0 TB | 8 TB | 7 | - | 29 | ||||
SATA | 0 TB | 8 TB | 7 | - | 29 | ||||
SSD | 0 TB | 30.6 TB | 7 | - | 29 | ||||
Footnote: | |||||||||
[1] The minimum number of disks in a RAID-DP group is three: at least one data disk, one regular parity disk, and one double-parity (dParity) disk. However, for non-root aggregates with only one RAID group, you must have at least 5 disks (three data disks and two parity disks). |
Supported Adapter Cards - FAS8300 Single Chassis HA Pair, Ethernet Bundle
Priority | Category | Bus Type | Mktg Part No. | Mfg Part No | Description | Plug Type | Optical Module Included? | Cables | Supported Protocol(s) | Min ONTAP | Max Qty [1] | Priority Slot Assignment | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Performance Acceleration | M.2 PCIe | X3311A | 111-03066 | 111-03066 | Flash Cache,1.0TB,NVMe | N/A | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||||||
2 | Block Access (Target) | PCIe3 | X1135A | 111-03648 | Fibre Channel 8/16/32 Gb,NVMe/FC 16/32 Gb | 111-03648 | 4p 32Gb FC SFP+ Op | SFP+ | Fibre Channel 8/16/32 Gb,NVMe/FC 16/32 Gb | View | Fibre Channel 8/16/32 Gb, | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
3 | Networking | PCIe3 | X1148A | 111-04025 | Ethernet 40/100 Gb | 111-04025 | 2p 100GbE RoCE QSFP28 | QSFP28 | Ethernet 40/100 Gb | View | Ethernet 40/100 Gb | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
4 | Networking | PCIe3 | X1122A | 111-04027 | Ethernet 10/25Gb,Ethernet 10Gb,Ethernet 25Gb | 111-04027 | 2p 25GbE RoCE SFP28 Cu|Op | SFP28 | Ethernet 10/25Gb,Ethernet 10Gb,Ethernet 25Gb | View | Ethernet 10/25Gb, | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
5 | Networking | PCIe3 | X1147A | 111-03854 | Ethernet 10Gb | 111-03854 | 4p 10GbE SFP+ Cu|Op | SFP+ | Ethernet 10Gb | View | Ethernet 10Gb | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
6 | Networking | PCIe3 | X1149A | 111-04451 | Ethernet 1/10 Gb | 111-04451 | 2p 10GBASE-T NIC Cu | RJ45 | Ethernet 1/10 Gb | View | Ethernet 1/10 Gb | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
7 | Storage (Initiator) | PCIe3 | X2072A | 111-04226 | SAS 6/12 Gb | 111-04226 | 4p 12Gb SAS miniSAS HD Cu|Op | MiniSAS HD | SAS 6/12 Gb | View | SAS 6/12 Gb | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
8 | Storage (Initiator) | PCIe3 | X2071A | 111-03801 | 111-03801 | 4p 12Gb SAS miniSAS HD Cu|Op | MiniSAS HD | View | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | ||||||||||
9 | Storage (Initiator) | PCIe3 | X1135A | 111-03648 | Fibre Channel 8/16/32 Gb,NVMe/FC 16/32 Gb | 111-03648 | 4p 32Gb FC SFP+ Op | SFP+ | Fibre Channel 8/16/32 Gb,NVMe/FC 16/32 Gb | View | Fibre Channel 8/16/32 Gb, | 9.7, 9.8, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
10 | Tape (Initiator) | PCIe3 | X2072A | 111-04226 | SAS 6/12 Gb | 111-04226 | 4p 12Gb SAS miniSAS HD Cu|Op | MiniSAS HD | SAS 6/12 Gb | View | SAS 6/12 Gb | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
11 | Tape (Initiator) | PCIe3 | X2071A | 111-03801 | 111-03801 | 4p 12Gb SAS miniSAS HD Cu|Op | MiniSAS HD | View | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | ||||||||||
12 | Tape (Initiator) | PCIe3 | X1135A [2] | 111-03648 | Fibre Channel 8/16/32 Gb,NVMe/FC 16/32 Gb | 111-03648 | 4p 32Gb FC SFP+ Op | SFP+ | Fibre Channel 8/16/32 Gb,NVMe/FC 16/32 Gb | View | Fibre Channel 8/16/32 Gb, | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |||||||
Footnote: | |||||||||||||||||||
[1] Values shown for max quantity are per controller. HA configurations will support 2x the values shown. | |||||||||||||||||||
[2] Connecting tape drives or tape libraries to FC or UTA2 ports requires the use of an FC switch. |
Supported Connections for FAS8300 Single Chassis HA Pair, Ethernet Bundle
Configuration Type | Port Configuration | Image | Cluster Ports per Node | Switch Ports per Node | |||||
---|---|---|---|---|---|---|---|---|---|
Cluster Interconnect | |||||||||
2-node Switchless Cluster | Default | View Image | 2 | None | |||||
Switched 100GbE or 40GbE | Supported | View Image | 2 | 2 | |||||
Switched 10GbE Interconnect | Supported | View Image | 4 | 4 | |||||
Switched 40GbE Interconnect (10GbE breakout) | Supported | View Image | 4 | 1 | |||||
HA Interconnect | |||||||||
HA Interconnect Switchless | HA Interconnect Switchless | N/A | 2 | 2 |
Platform Mixing Rules - FAS8300 Single Chassis HA Pair
Platform Configuration Type | Maximum Nodes (NAS) [1] | Maximum Nodes (SAN) [1] | Min ONTAP Version for Platform Mixing | ||||||
---|---|---|---|---|---|---|---|---|---|
FAS - Current Configuration(s) | |||||||||
FAS2720A 10GBASE-T | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS2720A 2-port UTA2 | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS2720A UTA2 | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS2750A 10GBASE-T | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS2750A 2-port UTA2 | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS2750A UTA2 | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS500fA | 24 Nodes | 12 Nodes | 9.8RC1 | ||||||
FAS8300A Ethernet Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS8300A FC Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS8700A Ethernet Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS8700A FC Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS9000A | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS9500A | 24 Nodes | 12 Nodes | 9.10.1P3 | ||||||
AllFlashFAS - Current Configuration(s) | |||||||||
AFF A250A | 24 Nodes | 12 Nodes | 9.8RC1 | ||||||
AFF A250A 100V | 24 Nodes | 12 Nodes | 9.8P4 | ||||||
AFF A400A Ethernet Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF A400A FC Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF A700A | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF A800A | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF A900A | 24 Nodes | 12 Nodes | 9.10.1 | ||||||
AFF C190A 10GBASE-T | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF C190A 2-port UTA2 | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF C190A UTA2 | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS - Legacy EOA Configuration(s) | |||||||||
FAS8200A | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AllFlashFAS - Legacy EOA Configuration(s) | |||||||||
AFF A220A 10GBASE-T | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF A220A UTA2 | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF A300A | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF A320A | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF A700s | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
Footnote: | |||||||||
[1] Maximum number of nodes within a cluster is determined by platform which supports the fewest number of nodes |
Product Standard Compliance - FAS8300 Single Chassis HA Pair, Ethernet Bundle
Standard | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|
Certifications EMC/EMI | |||||||||
AMCA | Australia and New Zealand (EMC covered by ACMA DoC) | ||||||||
FCC | Federal Communications Commission (EMI Declaration of Conformity covering United States and Canada) | ||||||||
ICES | ICES | ||||||||
KC | Korea Communications Commission (EMC certificate for South Korea) | ||||||||
Morocco | Morocco Declaration of Conformity | ||||||||
VCCI | EMI Certificate for Japan | ||||||||
Certifications safety | |||||||||
BIS | Bureau of Indian Standard (Safety cert for India) | ||||||||
CB | Certificate Body issued safety certificate covering International | ||||||||
CSA | Canadian Standards Association issued Safety certificate covering North America | ||||||||
G_K_U-SoR | Safety certificate for Gabon, Kenya and Uganda | ||||||||
IRAM | Instituto Argentino de Normalización y Certificación (safety certificate for Argentina) | ||||||||
NOM | Norma Oficial Mexicana (Safety cert for Mexico) | ||||||||
NRCS | National Regulator for Compulsory Specifications (Safety cert for South Africa) | ||||||||
SONCAP | Standards Organisation of Nigeria Conformity Assessment Programme (Safety cert for Nigeria) | ||||||||
TBS | Tanzanian Bureau of Standards (Safety certificate for Tanzania) | ||||||||
Certifications Safety/EMC/EMI | |||||||||
EAC | Euro Asia Conformity (EMC and Safety Cert) covering (Russia, Kazakhstan, Belarus, Armenia, Kyrgyzstan Countries) | ||||||||
UKRSEPRO | EMC/Safety certificate for Ukraine | ||||||||
Certifications Safety/EMC/EMI/RoHS | |||||||||
BSMI | Certificate for Taiwan | ||||||||
CE DoC | European Union Declaration of Conformity | ||||||||
UKCA DoC | UK Declaration of Conformity | ||||||||
Standards EMC/EMI | |||||||||
BS-EN-55024 | EMC standard for Great Britain | ||||||||
BS-EN55035 | EMC standard for Great Britain | ||||||||
CISPR 32 | EMI | ||||||||
EN55022 | EMC Standard fo European Union | ||||||||
EN55024 | EMC Standard fo European Union | ||||||||
EN55032 | EMI Standard fo European Union | ||||||||
EN55035 | EMC Standard for European Union | ||||||||
EN61000-3-2 | EMC Standard for European Union | ||||||||
EN61000-3-3 | EMC Standard for European Union | ||||||||
FCC Part 15 Class A | EMI standard for United States | ||||||||
ICES-003 | EMI Standard for Canada | ||||||||
KS C 9832 | EMI Standard for South Korea | ||||||||
KS C 9835 | EMC Standard for South Korea | ||||||||
Standards Safety | |||||||||
ANSI/UL60950-1 | Safety standard for United States | ||||||||
ANSI/UL62368-1 | Safety standard for United States | ||||||||
BS-EN62368-1 | Safety standard for Great Britain | ||||||||
CAN/CSA C22.2 No. 60950-1 | Safety Standard for Canada | ||||||||
CAN/CSA C22.2 No. 62368-1 | Safety Standard for Canada | ||||||||
CNS 14336 | Safety Standard for Taiwan | ||||||||
EN60825-1 | Laser Safety standard for European Union | ||||||||
EN62368-1 | Safety standard for European Union | ||||||||
IEC 62368-1 | Safety Standard for International | ||||||||
IEC60950-1 | Safety standard for International | ||||||||
IS 13252(part 1) | Safety Standard for India |
Supported OS Version - FAS8300 Single Chassis HA Pair, Ethernet Bundle
OS Major Version | Supported OS Version | Supported Milestones | Recommend Version | ||||||
---|---|---|---|---|---|---|---|---|---|
Currently Supported OS | |||||||||
ONTAP 9.11.1 | 9.11.1, 9.11.1RC1 | End of Full Support: 31-Jul-2025 End of Limited Support: 31-Jul-2027 End of Self-Service Support: 31-Jul-2030 | 9.11.1 | ||||||
ONTAP 9.10.1 | 9.10.1P5, 9.10.1P7, 9.10.1P6, 9.10.1P4, 9.10.1P3, 9.10.1P2, 9.10.1P1, 9.10.1, 9.10.1RC1 | End of Full Support: 31-Jan-2025 End of Limited Support: 31-Jan-2027 End of Self-Service Support: 31-Jan-2030 | 9.10.1P7, 9.10.1P6 | ||||||
ONTAP 9.9.1 | 9.9.1P11, 9.9.1P10, 9.9.1P9, 9.9.1P8, 9.9.1P7, 9.9.1P6, 9.9.1P5, 9.9.1P4, 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 | End of Full Support: 30-Jun-2024 End of Limited Support: 30-Jun-2026 End of Self-Service Support: 30-Jun-2029 | 9.9.1P11, 9.9.1P10, 9.9.1P9 | ||||||
ONTAP 9.8 | 9.8P13, 9.8P12, 9.8P11, 9.8P10, 9.8P9, 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4, 9.8P3, 9.8P2, 9.8P1, 9.8, 9.8RC1 | End of Full Support: 31-Dec-2023 End of Limited Support: 31-Dec-2025 End of Self-Service Support: 31-Dec-2028 | 9.8P13, 9.8P12 | ||||||
Definitions: | |||||||||
[1]End of Full Support: The date marking the end of Full Support for a particular feature version of a NetApp system software and the beginning of Limited Support. Abbreviated as EOES. | |||||||||
[2]End of Limited Support: The date marking the end of Limited Support for a particular feature version of a product and transition to Self-Service Support. Abbreviated as EOVS. | |||||||||
[3]End of Self-Service Support: NetApp does not provide support for a version of a software product, but related documentation is still available on the NetApp Support Site. NetApp customers are expected to utilize documentation to resolve issues. |
Supported Power Cords for FAS8300 Single Chassis HA Pair, Ethernet Bundle
Marketing Part No. | End 1 / End 2 | Length | Description | |
---|---|---|---|---|
Non-Cabinet Power Cords | ||||
X-50617-00 | IEC60320-C20 / IEC60320-C13 | 2.00 m | Power Cords,In-Cabinet,2m,C20-C13,E-Series | |
X800B-R6 | CEE 7/7 (Schuko) / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Cont Europe/Korea,10A/250V | |
X800C-R6 | BS1363 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,UK/Ireland,10A/250V | |
X800D-R6 | JIS-C-8303 / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,Japan,15A/125V | |
X800E-R6 | NEMA 5-15P / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,North America,15A/125V | |
X800F-R6 | AS/NZS 3112 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Aus/NZ,10A/250V | |
X800G-R6 | SEV 1011 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Switzerland,10A/250V | |
X800H-R6 | IRAM 2073 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Argentina,10A/250V | |
X800I-R6 | GB2099 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,China,10A/250V | |
X800J-R6 | DHCR107-2-D1 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Demark,10A/250V | |
X800K-R6 | SANS 164-1 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,India/S.Africa,10A/250V | |
X800L-R6 | SI32 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Israel,10A/250V | |
X800M-R6 | CEI 23-16 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Italy,10A/250V | |
X800N | EL208 / IEC60320-C13 | 2.50 m | Pwr Cord,10A,250V,2.5m,India | |
X800P-R6 | NEMA 6-15P / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,North America,15A/250V | |
X800T-R6 | CNS 10917-3 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Taiwan,BSMI,15A/125V | |
X800VB-R6 | NBR14136 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Brazil,10A/250V | |
X800W-R6 | CNS10917/CNS690 / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,Taiwan,10A/250V | |
X800Y-R6 | JIS-C-830 / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,Japan,15A/250V | |
In-Cabinet Power Cords | ||||
X1558A-R6 | IEC60320-C14 / IEC60320-C13 | 1.20 m | Pwr Cord,In-Cabinet,48-In,C13-C14,10A/250V | |
X800-42U-35 | IEC60320-C14 / IEC60320-C13 | 0.89 m | Pwr Cord,In-Cabinet,C13-C14,35-inch | |
X800-42U-43 | IEC60320-C14 / IEC60320-C13 | 1.09 m | Pwr Cord,In-Cabinet,C13-C14,43-inch | |
X800-42U-64 | IEC60320-C14 / IEC60320-C13 | 1.63 m | Pwr Cord,In-Cabinet,C13-C14,64-inch | |
X800-42U-R6 | IEC60320-C14 / IEC60320-C13 | 0.68 m | Pwr Cord,In-Cabinet,27-In,C13-C14,10A/250V |
Onboard Ports Configuration: FAS8300 Single Chassis HA Pair
Port Address | Description | Supported Protocols | Port Icon | Port Type | |||||
---|---|---|---|---|---|---|---|---|---|
0a | Serial-Attached SCSI | SAS 6/12 Gb | SAS | MiniSAS HD | |||||
0b | Serial-Attached SCSI | SAS 6/12 Gb | SAS | MiniSAS HD | |||||
0c | Serial-Attached SCSI | SAS 6/12 Gb | SAS | MiniSAS HD | |||||
0d | Serial-Attached SCSI | SAS 6/12 Gb | SAS | MiniSAS HD | |||||
e0a | HA Interconnect | Ethernet 25Gb | Ethernet | SFP28 | |||||
e0b | HA Interconnect | Ethernet 25Gb | Ethernet | SFP28 | |||||
e0c | Ethernet (RoCE) | Ethernet 40/100 Gb | Ethernet | QSFP28 | |||||
e0d | Ethernet (RoCE) | Ethernet 40/100 Gb | Ethernet | QSFP28 | |||||
e0e [1] | Ethernet | Ethernet 10/25Gb, Ethernet 1000Mb | Ethernet | SFP28 | |||||
e0f [1] | Ethernet | Ethernet 10/25Gb, Ethernet 1000Mb | Ethernet | SFP28 | |||||
e0g [1] | Ethernet | Ethernet 10/25Gb, Ethernet 1000Mb | Ethernet | SFP28 | |||||
e0h [1] | Ethernet | Ethernet 10/25Gb, Ethernet 1000Mb | Ethernet | SFP28 | |||||
e0m/BMC | Management | Ethernet 10/100/1000 Mb | Wrench | RJ45 | |||||
Serial Interface | USB Serial Console | RS-232 115200bps | USB 3.0 | USB 2.0 Micro-B | |||||
Serial Interface Icon | Serial Console | RS-232 115200bps | Serial Interface | RJ45 | |||||
USB/2 | Storage Host Port | USB 2.0 | USB 3.0 | USB Type A | |||||
Footnote: | |||||||||
[1] Ports e0e – e0h are provided by the 4-port 10/25GbE mezzanine module (X1161A) |
Supported Platform Configurations - FAS8300 Single Chassis HA Pair, Ethernet Bundle
Platform Configuration | Description | Chassis Configuration | Chassis Count | Controller Count (per chassis) | IOXM Count (per chassis) | Rack Units (Per System) | Weight (Per Chassis) | Min ONTAP | |
---|---|---|---|---|---|---|---|---|---|
HA Pair | |||||||||
FAS8300A Ethernet Bundle | FAS8300 Single Chassis HA Pair, Ethernet Bundle | CC | 1 | 2 | 0 | 4 | 108.47 lb (49.2 kg) | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS8300A FC Bundle | FAS8300 Single Chassis HA Pair, FC Bundle | CC | 1 | 2 | 0 | 4 | 108.47 lb (49.2 kg) | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
MetroCluster | |||||||||
FAS8300-2NBSMC Ethernet Bundle | FAS8300 2-Node Stretch MetroCluster, Fiber Bridge, Ethernet Bundle | Cb-HA | 2 | 1 | 0 | 8 | 81.57 lb (37 kg) | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS8300-2NBSMC FC Bundle | FAS8300 2-Node Stretch MetroCluster, Fiber Bridge, FC Bundle | Cb-HA | 2 | 1 | 0 | 8 | 81.57 lb (37 kg) | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS8300-2NDSMC Ethernet Bundle | FAS8300 2-Node Stretch MetroCluster, Optical SAS, Ethernet Bundle | Cb-HA | 2 | 1 | 0 | 8 | 81.57 lb (37 kg) | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS8300-2NDSMC FC Bundle | FAS8300 2-Node Stretch MetroCluster, Optical SAS, FC Bundle | Cb-HA | 2 | 1 | 0 | 8 | 81.57 lb (37 kg) | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS8300-2NFMC Ethernet Bundle | FAS8300 2-Node Fabric MetroCluster, Ethernet Bundle | Cb-HA | 2 | 1 | 0 | 8 | 81.57 lb (37 kg) | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS8300-2NFMC FC Bundle | FAS8300 2-Node Fabric MetroCluster, FC Bundle | Cb-HA | 2 | 1 | 0 | 8 | 81.57 lb (37 kg) | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS8300-4NFMC Ethernet Bundle | FAS8300 4-Node Fabric MetroCluster, Ethernet Bundle | CC-CC | 2 | 2 | 0 | 8 | 108.47 lb (49.2 kg) | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS8300-4NFMC FC Bundle | FAS8300 4-Node Fabric MetroCluster, FC Bundle | CC-CC | 2 | 2 | 0 | 8 | 108.47 lb (49.2 kg) | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS8300-4NMCIP Ethernet Bundle | FAS8300 4-Node MetroCluster IP, Ethernet Bundle | CC-CC | 2 | 2 | 0 | 8 | 108.47 lb (49.2 kg) | 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS8300-4NMCIP FC Bundle | FAS8300 4-Node MetroCluster IP, FC Bundle | CC-CC | 2 | 2 | 0 | 8 | 108.47 lb (49.2 kg) | 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS8300-8NFMC Ethernet Bundle | FAS8300 8-Node Fabric MetroCluster, Ethernet Bundle | 2x(CC-CC) | 4 | 2 | 0 | 16 | 108.47 lb (49.2 kg) | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS8300-8NFMC FC Bundle | FAS8300 8-Node Fabric MetroCluster, FC Bundle | 2x(CC-CC) | 4 | 2 | 0 | 16 | 108.47 lb (49.2 kg) | 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS8300-8NMCIP Ethernet Bundle | FAS8300 8-Node MetroCluster IP, Ethernet Bundle | 2x(CC-CC) | 4 | 2 | 0 | 16 | 108.47 lb (49.2 kg) | 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
FAS8300-8NMCIP FC Bundle | FAS8300 8-Node MetroCluster IP, FC Bundle | 2x(CC-CC) | 4 | 2 | 0 | 16 | 108.47 lb (49.2 kg) | 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 |
Platform Memory Specifications - FAS8300 Single Chassis HA Pair, Ethernet Bundle
Part Number | Description | Mfg Part Number | Non-Volatile | Qty | Capacity (GB) | NVRAM/NVMEM Used Capacity (GB) | RAM Used Capacity (GB) |
---|---|---|---|---|---|---|---|
X93144A | 32GB RDIMM | 107-00215 | no | 8 | 32 | 256 | |
X93143A | 16GB NVDIMM | 107-00216 | yes | 2 | 16 | 32 | - |
X93145A | 16GB NVDIMM | 107-00237 | yes | 2 | 16 | 32 | - |
Supported Rail Kit for FAS8300 Single Chassis HA Pair, Ethernet Bundle
Marketing Part No. | Manufacturing Part No. | Description | |
---|---|---|---|
NetApp System Cabinet Rail Kits | |||
X87880A | 111-03887 | Rail Kit 4,Cabinet | |
Third-Party Cabinet Rail Kits | |||
X-02659-00 | 113-00232 | Kit,4-Post,Square or Round-Hole, 24"-32" Rail |
Field Replacement Unit Parts - FAS8300 Single Chassis HA Pair, Ethernet Bundle
Marketing Part No. | Manufacturing Part No. | Description | |
---|---|---|---|
Adapter Card | |||
X1122A | 111-04027 | NIC 2-Pt Bare Cage 25GbE RoCE SFP28 PCIe | |
X1122A-C | 111-04027 | NIC 2-Pt Bare Cage 25GbE RoCE SFP28 PCIe,-C | |
X1122A-N-C | 111-04027 | NIC 2-Pt Bare Cage 25GbE RoCE SFP28 PCIe,-C | |
X1135A [1] | 111-03648 | HBA,4-port FCP Targt-Init 32Gb PCIe w/SFP+ | |
X1135A-C [1] | 111-03648 | HBA,4-port FCP Targt-Init 32Gb PCIe w/SFP+,-C | |
X1135A-N-C [1] | 111-03648 | HBA,4-port FCP Targt-Init 32Gb PCIe w/SFP+,-C | |
X1147A | 111-03854 | NIC 4-Port Bare Cage 10GbE SFP+ PCIe | |
X1147A-C | 111-03854 | NIC 4-Port Bare Cage 10GbE SFP+ PCIe,-C | |
X1147A-N-C | 111-03854 | NIC 4-Port Bare Cage 10GbE SFP+ PCIe,-C | |
X1148A | 111-04025 | NIC 2-Pt BareCage 100GbE RoCE QSFP28 PCIe | |
X1148A-C | 111-04025 | NIC 2-Pt BareCage 100GbE RoCE QSFP28 PCIe,-C | |
X1148A-N-C | 111-04025 | NIC 2-Pt BareCage 100GbE RoCE QSFP28 PCIe,-C | |
X1149A | 111-04451 | NIC 2-Pt 10G Base-T,HBA | |
X1149A-N-C | 111-04451 | HBA 10GBASE-T,2 PORT,INTEL,-C | |
X2071A | 111-03801 | HBA,4-Port HD-miniSAS,12Gb,PCIe | |
X2071A-C | 111-03801 | HBA,4-Port HD-miniSAS,12Gb,PCIe,-C | |
X2071A-N-C | 111-03801 | HBA,4-Port HD-miniSAS,12Gb,PCIe,-C | |
X2072A | 111-04226 | HBA,4x12Gb miniSAS HD,PCIe | |
X2072A-N-C | 111-04226 | HBA,4x12Gb miniSAS HD,PCIe gen3x16,-C | |
X3311A | 111-03066 | SUB ASSY,NVME,FLASH,1.0TB | |
Battery | |||
X1847 | 271-01847 | Lithium System Battery CR2032 | |
X1847-R6 | 271-01847 | Lithium System Battery CR2032,R6 | |
X3156A | 111-04057 | Batt,LI-ION,7.2V,2-CELL,CYL,GEN5 | |
Bezel | |||
X80115A | 111-04202 | Bezel,FAS8300 | |
Blank | |||
X3119 | 111-04262 | Blanking Panel,SYS CNTRL,8300,8700,A400 | |
X3119-N-C | 111-04262 | Blanking Panel,SYS CNTRL,8300,8700,A400,-C | |
Boot Media | |||
X3323A | 111-04228 | M.2,SATA,FLASH,480GB | |
Chassis | |||
X3164A | 111-04200 | Chassis,W/MIDPLANE/FAN,A400,8300/8700 | |
X3165A | 111-04200, 111-04203 | Chassis,W/MIDPLANE,NO FAN,A400,8300/8700 | |
Data Cable | |||
X-QSFP-4SFP10G-CU3M | 112-00602 | Cable,Cisco,QSFP/4xSFP10G,CU Passive,3m | |
X-QSFP-4SFP10G-CU3M-C | 112-00602 | Cable,Cisco,QSFP/4xSFP10G,CU Passive,3m,-C | |
X-QSFP-4SFP10G-CU3M-N-C | 112-00602 | Cable,Cisco,QSFP/4xSFP10G,CU Passive,3m,-C | |
X-QSFP-4SFP10G-CU5M | 112-00603 | Cable,Cisco,QSFP/4xSFP10G,CU Passive,5m | |
X-QSFP-4SFP10G-CU5M-C | 112-00603 | Cable,Cisco,QSFP/4xSFP10G,CU Passive,5m,-C | |
X-QSFP-4SFP10G-CU5M-N-C | 112-00603 | Cable,Cisco,QSFP/4xSFP10G,CU Passive,5m,-C | |
X-SFP-H10GB-CU1M-R6 | 112-00210 | Cable,10GBase Copper SFP+ 1m | |
X-SFP-H10GB-CU1M-R6-C | 112-00210 | Cable,10GBase Copper SFP+ 1m,-C | |
X-SFP-H10GB-CU1M-R6-N-C | 112-00210 | Cable,10GBase Copper SFP+ 1m,-C | |
X-SFP-H10GB-CU3M-R6 | 112-00211 | Cable,10GBase Copper SFP+ 3m | |
X-SFP-H10GB-CU3M-R6-C | 112-00211 | Cable,10GBase Copper SFP+ 3m,-C | |
X-SFP-H10GB-CU3M-R6-N-C | 112-00211 | Cable,10GBase Copper SFP+ 3m,-C | |
X-SFP-H10GB-CU5M-R6 | 112-00212 | Cable,10GBase Copper SFP+ 5m | |
X-SFP-H10GB-CU5M-R6-C | 112-00212 | Cable,10GBase Copper SFP+ 5m,-C | |
X-SFP-H10GB-CU5M-R6-N-C | 112-00212 | Cable,10GBase Copper SFP+ 5m,-C | |
X1983-1-R6 | 112-00210 | Cable,Twinax CU,SFP+,1M,X1962/X1963/X1967 | |
X1983-3-R6 | 112-00211 | Cable,Twinax CU,SFP+,3M,X1962/X1963/X1967 | |
X1983-5-R6 | 112-00212 | Cable,Twinax CU,SFP+,5M,X1962/X1963/X1967 | |
X6536-R6 | 112-00090 | Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op | |
X6536-R6-C | 112-00090 | Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op,-C | |
X6536-R6-N-C | 112-00090 | Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op,-C | |
X6537-R6 | 112-00091 | Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op | |
X6537-R6-C | 112-00091 | Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op,-C | |
X6537-R6-N-C | 112-00091 | Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op,-C | |
X65420 | 112-00508 | Cable,ASSY,USB 2.0 MICRO-B,USB-A,2M | |
X6546-R6 | 112-00074 | Cable,Cntlr-Shelf/Switch,30m,LC/SC,Op | |
X6547-R6 | 112-00073 | Cable,Cntlr-Shelf/Switch,5m,LC/SC,Op | |
X6553-R6 | 112-00188 | Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op | |
X6553-R6-C | 112-00188 | Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op,-C | |
X6553-R6-N-C | 112-00188 | Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op,-C | |
X6554-R6 | 112-00189 | Cable,Cntlr-Shelf/Switch,15m,LC/LC,Op | |
X6554-R6-C | 112-00189 | Cable,OPT,50u,2GHz/KM,MM,LC/LC,15M,-C,R6 | |
X6554-R6-N-C | 112-00189 | Cable,OPT,50u,2GHz/KM,MM,LC/LC,15M,-C,R6,-C | |
X6560-R6 | 112-00194 | Cable,Ethernet,0.5m RJ45 CAT6 | |
X6560-R6-C | 112-00194 | Cable,Ethernet,0.5m RJ45 CAT6,-C | |
X6560-R6-N-C | 112-00194 | Cable,Ethernet,0.5m RJ45 CAT6 | |
X6561-R6 | 112-00195 | Cable,Ethernet,2m RJ45 CAT6 | |
X6561-R6-C | 112-00195 | Cable,Ethernet,2m RJ45 CAT6,-C | |
X6561-R6-N-C | 112-00195 | Cable,Ethernet,2m RJ45 CAT6,-C | |
X6562-R6 | 112-00196 | Cable,Ethernet,5m RJ45 CAT6 | |
X6562-R6-C | 112-00196 | Cable,Ethernet,5m RJ45 CAT6,-C | |
X6562-R6-N-C | 112-00196 | Cable,Ethernet,5m RJ45 CAT6,-C | |
X6566B-05-N-C | 112-00297 | Cable,Direct Attach CU SFP+ 10G,0.5M,-C | |
X6566B-05-R6 | 112-00297 | Cable,Direct Attach CU SFP+ 10G,0.5M | |
X6566B-05-R6-C | 112-00297 | Cable,Direct Attach CU SFP+ 10G,0.5M,-C | |
X6566B-2-N-C | 112-00299 | Cable,Direct Attach CU SFP+ 10G,2M,-C | |
X6566B-2-R6 | 112-00299 | Cable,Direct Attach CU SFP+ 10G,2M | |
X6566B-2-R6-C | 112-00299 | Cable,Direct Attach CU SFP+ 10G,2M,-C | |
X6566B-3-N-C | 112-00300 | Cable,Direct Attach CU SFP+ 10G,3M,-C | |
X6566B-3-R6 | 112-00300 | Cable,Direct Attach CU SFP+ 10G,3M | |
X6566B-3-R6-C | 112-00300 | Cable,Direct Attach CU SFP+ 10G,3M,-C | |
X6566B-5-N-C | 112-00301 | Cable,Direct Attach CU SFP+ 10G,5M,-C | |
X6566B-5-R6 | 112-00301 | Cable,Direct Attach CU SFP+ 10G,5M | |
X6566B-5-R6-C | 112-00301 | Cable,Direct Attach CU SFP+ 10G,5M,-C | |
X6577-R6 | 112-00238 | Cable,Ethernet,30m RJ45 CAT6 | |
X6577-R6-C | 112-00238 | Cable,Ethernet,30m RJ45 CAT6,-C | |
X6577-R6-N-C | 112-00238 | Cable,Ethernet,30m RJ45 CAT6,-C | |
X6584-R6 | 112-00290 | Cable,Ethernet,1m RJ45 CAT6 | |
X6584-R6-C | 112-00290 | Cable,Ethernet,1m RJ45 CAT6,-C | |
X6584-R6-N-C | 112-00290 | Cable,Ethernet,1m RJ45 CAT6,-C | |
X6585-R6 | 112-00291 | Cable,Ethernet,3m RJ45 CAT6 | |
X6585-R6-C | 112-00291 | Cable,Ethernet,3m RJ45 CAT6,-C | |
X6585-R6-N-C | 112-00291 | Cable,Ethernet,3m RJ45 CAT6,-C | |
X66020A-R6 | 112-00429 | Cable,Storage,MiniSAS HD,QSFP,12G,1m | |
X66020A-R6-C | 112-00429 | Cable,Storage,MiniSAS HD,QSFP,12G,1m,-C | |
X66021A-R6 | 112-00430 | Cable,Storage,MiniSAS HD,QSFP,12G,2m | |
X66021A-R6-C | 112-00430 | Cable,Storage,MiniSAS HD,QSFP,12G,2m,-C | |
X66022A-R6 | 112-00431 | Cable,Storage,MiniSAS HD,QSFP,12G,5m | |
X66022A-R6-C | 112-00431 | Cable,Storage,MiniSAS HD,QSFP,12G,5m,-C | |
X66030A | 112-00435 | Cable,12Gb,Mini SAS HD,0.5m | |
X66030A-C | 112-00435 | Cable,12Gb,Mini SAS HD,0.5m,-C | |
X66030A-K-N | 112-00435 | Cable,12Gb,Mini SAS HD,0.5m | |
X66030A-N | 112-00435 | Cable,12Gb,Mini SAS HD,0.5m | |
X66030A-N-C | 112-00435 | Cable,12Gb,Mini SAS HD,0.5m,-C | |
X66031A | 112-00436 | Cable,12Gb,Mini SAS HD,1m | |
X66031A-C | 112-00436 | Cable,12Gb,Mini SAS HD,1m,-C | |
X66031A-K-N | 112-00436 | Cable,12Gb,Mini SAS HD,1m | |
X66031A-N | 112-00436 | Cable,12Gb,Mini SAS HD,1m | |
X66031A-N-C | 112-00436 | Cable,12Gb,Mini SAS HD,1m,-C | |
X66032A | 112-00437 | Cable,12Gb,Mini SAS HD,2m | |
X66032A-C | 112-00437 | Cable,12Gb,Mini SAS HD,2m,-C | |
X66032A-K-N | 112-00437 | Cable,12Gb,Mini SAS HD,2m | |
X66032A-N | 112-00437 | Cable,12Gb,Mini SAS HD,2m | |
X66032A-N-C | 112-00437 | Cable,12Gb,Mini SAS HD,2m,-C | |
X66033A | 112-00438 | Cable,12Gb,Mini SAS HD,3m | |
X66033A-C | 112-00438 | Cable,12Gb,Mini SAS HD,3m,-C | |
X66033A-K-N | 112-00438 | Cable,12Gb,Mini SAS HD,3m | |
X66033A-N | 112-00438 | Cable,12Gb,Mini SAS HD,3m | |
X66033A-N-C | 112-00438 | Cable,12Gb,Mini SAS HD,3m,-C | |
X66034A | 112-00439 | Cable,12Gb,Mini SAS HD,5m | |
X66034A-C | 112-00439 | Cable,12Gb,Mini SAS HD,5m,-C | |
X66034A-K-N | 112-00439 | Cable,12Gb,Mini SAS HD,5m | |
X66034A-N | 112-00439 | Cable,12Gb,Mini SAS HD,5m | |
X66034A-N-C | 112-00439 | Cable,12Gb,Mini SAS HD,5m,-C | |
X66040A | 112-00449 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m | |
X66040A-C | 112-00449 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m,-C | |
X66040A-K-N | 112-00449 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m | |
X66040A-N | 112-00449 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m | |
X66040A-N-C | 112-00449 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m,-C | |
X66041A | 112-00450 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m | |
X66041A-C | 112-00450 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m,-C | |
X66041A-K-N | 112-00450 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m | |
X66041A-N | 112-00450 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m | |
X66041A-N-C | 112-00450 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m,-C | |
X66042A | 112-00451 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m | |
X66042A-C | 112-00451 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m,-C | |
X66042A-K-N | 112-00451 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m | |
X66042A-N | 112-00451 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m | |
X66042A-N-C | 112-00451 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m,-C | |
X66043A | 112-00452 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m | |
X66043A-C | 112-00452 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m,-C | |
X66043A-K-N | 112-00452 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m | |
X66043A-N | 112-00452 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m | |
X66043A-N-C | 112-00452 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m,-C | |
X66044A | 112-00453 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,15m | |
X66045A | 112-00454 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,30m | |
X66046A | 112-00455 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,50m | |
X66047A | 112-00456 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,5m | |
X66047A-C | 112-00456 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,5m,-C | |
X66047A-N-C | 112-00456 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,5m,-C | |
X66048A | 112-00457 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,30m | |
X66048A-C | 112-00457 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,30m,-C | |
X66048A-N-C | 112-00457 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,30m,-C | |
X66100-1 | 112-00542 | Cable,Direct Attach CU QSFP,40Gb,1m | |
X66100-1-C | 112-00542 | Cable,Direct Attach CU QSFP,40Gb,1m,-C | |
X66100-1-K-N | 112-00542 | Cable,Direct Attach CU QSFP,40Gb,1m | |
X66100-1-N | 112-00542 | Cable,Direct Attach CU QSFP,40Gb,1m | |
X66100-1-N-C | 112-00542 | Cable,Direct Attach CU QSFP,40Gb,1m,-C | |
X66100-3 | 112-00543 | Cable,Direct Attach CU QSFP,40Gb,3m | |
X66100-3-C | 112-00543 | Cable,Direct Attach CU QSFP,40Gb,3m,-C | |
X66100-3-K-N | 112-00543 | Cable,Direct Attach CU QSFP,40Gb,3m | |
X66100-3-N | 112-00543 | Cable,Direct Attach CU QSFP,40Gb,3m | |
X66100-3-N-C | 112-00543 | Cable,Direct Attach CU QSFP,40Gb,3m,-C | |
X66100-5 | 112-00544 | Cable,Direct Attach CU QSFP,40Gb,5m | |
X66100-5-C | 112-00544 | Cable,Direct Attach CU QSFP,40Gb,5m,-C | |
X66100-5-K-N | 112-00544 | Cable,Direct Attach CU QSFP,40Gb,5m | |
X66100-5-N | 112-00544 | Cable,Direct Attach CU QSFP,40Gb,5m | |
X66100-5-N-C | 112-00544 | Cable,Direct Attach CU QSFP,40Gb,5m,-C | |
X66200-15 | 112-00330 | Cable,Cntlr-Switch OM4,MPO/MPO,15m | |
X66200-15-C | 112-00330 | Cable,Cntlr-Switch OM4,MPO/MPO,15m,-C | |
X66200-15-N-C | 112-00330 | Cable,Cntlr-Switch OM4,MPO/MPO,15m,-C | |
X66200-2 | 112-00326 | Cable,Cntlr-Switch OM4,MPO/MPO,2m | |
X66200-2-C | 112-00326 | Cable,Cntlr-Switch OM4,MPO/MPO,2m,-C | |
X66200-2-N-C | 112-00326 | Cable,Cntlr-Switch OM4,MPO/MPO,2m,-C | |
X66200-30 | 112-00331 | Cable,Cntlr-Switch OM4,MPO/MPO,30m | |
X66200-30-C | 112-00331 | Cable,Cntlr-Switch OM4,MPO/MPO,30m,-C | |
X66200-30-N-C | 112-00331 | Cable,Cntlr-Switch OM4,MPO/MPO,30m,-C | |
X66200-5 | 112-00328 | Cable,Cntlr-Switch OM4,MPO/MPO,5m | |
X66200-5-C | 112-00328 | Cable,Cntlr-Switch OM4,MPO/MPO,5m,-C | |
X66200-5-N-C | 112-00328 | Cable,Cntlr-Switch OM4,MPO/MPO,5m,-C | |
X66205-30 | 112-00261 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m | |
X66205-30-C | 112-00261 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m,-C | |
X66205-30-N-C | 112-00261 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m,-C | |
X66205-5 | 112-00260 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m | |
X66205-5-C | 112-00260 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m,-C | |
X66205-5-N-C | 112-00260 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m,-C | |
X66211A-05 | 112-00595 | Cable,100GbE,QSFP28-QSFP28,Cu,0.5m | |
X66211A-05-C | 112-00595 | Cable,100GbE,QSFP28-QSFP28,Cu,0.5m,-C | |
X66211A-05-K-N | 112-00595 | Cable,100GbE,QSFP28-QSFP28,Cu,0.5m | |
X66211A-05-N | 112-00595 | Cable,100GbE,QSFP28-QSFP28,Cu,0.5m | |
X66211A-05-N-C | 112-00595 | Cable,100GbE,QSFP28-QSFP28,Cu,0.5m,-C | |
X66211A-1 | 112-00573 | Cable,100GbE,QSFP28-QSFP28,Cu,1m | |
X66211A-1-K-N | 112-00573 | Cable,100GbE,QSFP28-QSFP28,Cu,1m | |
X66211A-1-N | 112-00573 | Cable,100GbE,QSFP28-QSFP28,Cu,1m | |
X66211A-2 | 112-00574 | Cable,100GbE,QSFP28-QSFP28,Cu,2m | |
X66211A-2-K-N | 112-00574 | Cable,100GbE,QSFP28-QSFP28,Cu,2m | |
X66211A-2-N | 112-00574 | Cable,100GbE,QSFP28-QSFP28,Cu,2m | |
X66211A-5 | 112-00576 | Cable,100GbE,QSFP28-QSFP28,Cu,5m | |
X66211A-5-K-N | 112-00576 | Cable,100GbE,QSFP28-QSFP28,Cu,5m | |
X66211A-5-N | 112-00576 | Cable,100GbE,QSFP28-QSFP28,Cu,5m | |
X66211B-1-C | 112-00573 | Cable,100GbE,QSFP28-QSFP28,Cu,1m,-C | |
X66211B-1-N-C | 112-00573 | Cable,100GbE,QSFP28-QSFP28,Cu,1m,-C | |
X66211B-2-C | 112-00574 | Cable,100GbE,QSFP28-QSFP28,Cu,2m,-C | |
X66211B-2-N-C | 112-00574 | Cable,100GbE,QSFP28-QSFP28,Cu,2m,-C | |
X66211B-5-C | 112-00576 | Cable,100GbE,QSFP28-QSFP28,Cu,5m,-C | |
X66211B-5-N-C | 112-00576 | Cable,100GbE,QSFP28-QSFP28,Cu,5m,-C | |
X66220A-15 | 112-00586 | Cable,100GbE,QSFP28-QSFP28,AOC,15m | |
X66220A-15-N-C | 112-00586 | Cable,100GbE,QSFP28-QSFP28,AOC,15m,-C | |
X66220A-30 | 112-00589 | Cable,100GbE,QSFP28-QSFP28,AOC,30m | |
X66220A-30-N-C | 112-00589 | Cable,100GbE,QSFP28-QSFP28,AOC,30m,-C | |
X66240A-05 | 1111455002, 112-00639, NDCCGF-0006 | Cable,25GbE,SFP28-SFP28,Cu,0.5m | |
X66240A-05-N-C | 1111455002, 112-00639, NDCCGF-0006 | Cable,25GbE,SFP28-SFP28,Cu,0.5m,-C | |
X66240A-2 | 1111455000, 112-00598, NDCCGF-C102, NDCCGF-N102 | Cable,25GbE,SFP28-SFP28,Cu,2m | |
X66240A-2-N-C | 1111455000, 112-00598, NDCCGF-C102, NDCCGF-N102 | Cable,25GbE,SFP28-SFP28,Cu,2m,-C | |
X66240A-5 | 1111455001, 112-00600, NDCCGJ-C102, NDCCGJ-N105 | Cable,25GbE,SFP28-SFP28,Cu,5m | |
X66240A-5-N-C | 1111455001, 112-00600, NDCCGJ-C102, NDCCGJ-N105 | Cable,25GbE,SFP28-SFP28,Cu,5m,-C | |
X66250-15 | 112-00346 | Cable,LC-LC,OM4,15m | |
X66250-15-C | 112-00346 | Cable,LC-LC,OM4,15m,-C | |
X66250-15-N-C | 112-00346 | Cable,LC-LC,OM4,15m,-C | |
X66250-2 | 112-00342 | Cable,LC-LC,OM4,2m | |
X66250-2-C | 112-00342 | Cable,LC-LC,OM4,2m,-C | |
X66250-2-N-C | 112-00342 | Cable,LC-LC,OM4,2m,-C | |
X66250-30 | 112-00347 | Cable,LC-LC,OM4,30m | |
X66250-30-C | 112-00347 | Cable,LC-LC,OM4,30m,-C | |
X66250-30-N-C | 112-00347 | Cable,LC-LC,OM4,30m,-C | |
X66250-5 | 112-00344 | Cable,LC-LC,OM4,5m | |
X66250-5-C | 112-00344 | Cable,LC-LC,OM4,5m,-C | |
X66250-5-N-C | 112-00344 | Cable,LC-LC,OM4,5m,-C | |
X66260-30 | 112-00354 | Cable,LC-LC,OPT,OS2,30M | |
X66260-30-C | 112-00354 | Cable,LC-LC,OPT,OS2,30M,-C | |
X66260-30-N-C | 112-00354 | Cable,LC-LC,OPT,OS2,30M,-C | |
X66260-5 | 112-00353 | Cable,LC-LC,OPT,OS2,5M | |
X66260-5-C | 112-00353 | Cable,LC-LC,OPT,OS2,5M,-C | |
X66260-5-N-C | 112-00353 | Cable,LC-LC,OPT,OS2,5M,-C | |
Drive | |||
X302A-R5 | 108-00268 | Disk Drive,1.0TB 7.2k,DS424x,FAS2240-4 | |
X306A-R5 | 108-00270 | Disk Drive,2.0TB 7.2k,DS424x,2554/2240-4 | |
X308A-R5 | 108-00277 | Disk Drive,3.0TB 7.2K,DS424x,2554/2240-4 | |
X309A-R6 [2] | 108-00301 | DSK DRV,3TB 7.2k,NSE,DS424x,FAS2220/2240-4 | |
X315A-R6 [2] | 108-00368 | DSK DRV,4TB 7.2k,NSE,DS424x,2554/2220/2240-4 | |
X316A-R6 | 108-00389 | Disk Drive,6TB 7.2k,DS4246,FAS2554 | |
X317A [2] | 108-00399 | DSK DRV,6TB,7.2K,12G,NSE,DS212C | |
X318A-R6 | 108-00455 | DSK DRV,8TB,7.2K,12G,DS212C | |
X319A | 108-00687 | SSD,7.6TB,12G,DS224C |
Supported Firmware Matrix - FAS8300 Single Chassis HA Pair, Ethernet Bundle
Major OS Version | OS Version | Firmeware | |||||||
---|---|---|---|---|---|---|---|---|---|
BIOS | |||||||||
ONTAP 9.11.1 | 9.11.1RC1 | 16.7* | |||||||
ONTAP 9.10.1 | 9.10.1P7, 9.10.1P5-P6 | 16.7* | |||||||
ONTAP 9.10.1 | 9.10.1P3-P4, 9.10.1P2, 9.10.1P1 | 16.7, 16.6 Loader 6.4.12* | |||||||
ONTAP 9.10.1 | 9.10.1, 9.10.1RC1 | 16.7, 16.6 Loader 6.4.12, 16.6 Loader 6.4.11* | |||||||
ONTAP 9.9.1 | 9.9.1P11 | 16.7* | |||||||
ONTAP 9.9.1 | 9.9.1P10, 9.9.1P8-P9, 9.9.1P7 | 16.7, 16.6 Loader 6.4.12* | |||||||
ONTAP 9.9.1 | 9.9.1P4-P6 | 16.7, 16.6 Loader 6.4.12, 16.6 Loader 6.4.11* | |||||||
ONTAP 9.9.1 | 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 | 16.7, 16.6 Loader 6.4.12, 16.6 Loader 6.4.11, 16.4* | |||||||
ONTAP 9.8 | 9.8P13 | 16.7* | |||||||
ONTAP 9.8 | 9.8P11-P12 | 16.7, 16.6 Loader 6.4.12* | |||||||
ONTAP 9.8 | 9.8P10, 9.8P9 | 16.7, 16.6 Loader 6.4.12, 16.6 Loader 6.4.11* | |||||||
ONTAP 9.8 | 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4 | 16.7, 16.6 Loader 6.4.12, 16.6 Loader 6.4.11, 16.4* | |||||||
ONTAP 9.8 | 9.8P3, 9.8P2 | 16.7, 16.6 Loader 6.4.12, 16.6 Loader 6.4.11, 16.4, 16.3* | |||||||
ONTAP 9.8 | 9.8P1 | 16.7, 16.6 Loader 6.4.12, 16.6 Loader 6.4.11, 16.4, 16.3, 16.2.1* | |||||||
ONTAP 9.8 | 9.8, 9.8RC1 | 16.7, 16.6 Loader 6.4.12, 16.6 Loader 6.4.11, 16.4, 16.3, 16.2.1, 16.2* | |||||||
ONTAP 9.7 | 9.7P19 | 16.7, 16.6 Loader 6.4.12* | |||||||
ONTAP 9.7 | 9.7P17-P18 | 16.7, 16.6 Loader 6.4.12, 16.6 Loader 6.4.11* | |||||||
ONTAP 9.7 | 9.7P16, 9.7P15, 9.7P14 | 16.7, 16.6 Loader 6.4.12, 16.6 Loader 6.4.11, 16.4* | |||||||
ONTAP 9.7 | 9.7P13, 9.7P12 | 16.7, 16.6 Loader 6.4.12, 16.6 Loader 6.4.11, 16.4, 16.3* | |||||||
ONTAP 9.7 | 9.7P11 | 16.7, 16.6 Loader 6.4.12, 16.6 Loader 6.4.11, 16.4, 16.3, 16.2.1* | |||||||
ONTAP 9.7 | 9.7P10, 9.7P9, 9.7P8 | 16.7, 16.6 Loader 6.4.12, 16.6 Loader 6.4.11, 16.4, 16.3, 16.2.1, 16.2* | |||||||
ONTAP 9.7 | 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1 | 16.7, 16.6 Loader 6.4.12, 16.6 Loader 6.4.11, 16.4, 16.3, 16.2.1, 16.2, 16.1.1, 16.1* | |||||||
ONTAP 9.7 | 9.7, 9.7RC1 | 16.7, 16.6 Loader 6.4.12, 16.6 Loader 6.4.11, 16.4, 16.3, 16.2.1, 16.2, 16.1.1, 16.1, 16.0* | |||||||
BMC | |||||||||
ONTAP 9.11.1 | 9.11.1 | 13.6P1 | |||||||
ONTAP 9.11.1 | 9.11.1RC1 | 13.6P1, 13.6* | |||||||
ONTAP 9.10.1 | 9.10.1P7, 9.10.1P5-P6, 9.10.1P3-P4, 9.10.1P2, 9.10.1P1 | 13.6P1, 13.6, 13.5P1* | |||||||
ONTAP 9.10.1 | 9.10.1, 9.10.1RC1 | 13.6P1, 13.6, 13.5P1, 13.5* | |||||||
ONTAP 9.9.1 | 9.9.1P11, 9.9.1P10, 9.9.1P8-P9, 9.9.1P7 | 13.6P1, 13.6, 13.5P1* | |||||||
ONTAP 9.9.1 | 9.9.1P4-P6 | 13.6P1, 13.6, 13.5P1, 13.5* | |||||||
ONTAP 9.9.1 | 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 | 13.6P1, 13.6, 13.5P1, 13.5, 13.4P2* | |||||||
ONTAP 9.8 | 9.8P13, 9.8P11-P12 | 13.6P1, 13.6, 13.5P1* | |||||||
ONTAP 9.8 | 9.8P10, 9.8P9, 9.8P8 | 13.6P1, 13.6, 13.5P1, 13.5* | |||||||
ONTAP 9.8 | 9.8P7, 9.8P6, 9.8P5 | 13.6P1, 13.6, 13.5P1, 13.5, 13.4P2* | |||||||
ONTAP 9.8 | 9.8P4 | 13.6P1, 13.6, 13.5P1, 13.5, 13.4P2, 13.4P1* | |||||||
ONTAP 9.8 | 9.8P3, 9.8P2, 9.8P1 | 13.6P1, 13.6, 13.5P1, 13.5, 13.4P2, 13.4P1, 13.4* | |||||||
ONTAP 9.8 | 9.8, 9.8RC1 | 13.6P1, 13.6, 13.5P1, 13.5, 13.4P2, 13.4P1, 13.4, 13.3, 13.2P1* | |||||||
ONTAP 9.7 | 9.7P19 | 13.6P1, 13.6, 13.5P1* | |||||||
ONTAP 9.7 | 9.7P17-P18 | 13.6P1, 13.6, 13.5P1, 13.5* | |||||||
ONTAP 9.7 | 9.7P16, 9.7P15, 9.7P14 | 13.6P1, 13.6, 13.5P1, 13.5, 13.4P2* | |||||||
ONTAP 9.7 | 9.7P13, 9.7P12 | 13.6P1, 13.6, 13.5P1, 13.5, 13.4P2, 13.4P1, 13.4* | |||||||
ONTAP 9.7 | 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2 | 13.6P1, 13.6, 13.5P1, 13.5, 13.4P2, 13.4P1, 13.4, 13.3, 13.2P1, 13.2* | |||||||
ONTAP 9.7 | 9.7P1, 9.7, 9.7RC1 | 13.6P1, 13.6, 13.5P1, 13.5, 13.4P2, 13.4P1, 13.4, 13.3, 13.2P1, 13.2, 13.1P1* | |||||||
Footnote: | |||||||||
[1]* Indicates that firmware is bundled with Storage OS Version |
Product Certificates - FAS8300 Single Chassis HA Pair, Ethernet Bundle
Certificate Name | Geo / Region / Country | Associated Products | |||||||
---|---|---|---|---|---|---|---|---|---|
Battery Pack safety reports | |||||||||
Lithium Battery Safety Doc-Section II/Section IB Shipments,Inventus Power Product Model#271-00045AWB | Global | Platforms : AFF A220, AFF A320, AFF A400, AFF A700s, AFF A800, AFF C190, FAS2620, FAS2650, FAS2720, FAS2750, FAS8300, FAS8700 | |||||||
EMI and Safety certificates | |||||||||
Lithium Battery Safety Doc-Section II/Section IB Shipments,Inventus Power Product Model#271-00045AWB | Global | Platforms : AFF A220, AFF A320, AFF A400, AFF A700s, AFF A800, AFF C190, FAS2620, FAS2650, FAS2720, FAS2750, FAS8300, FAS8700 | |||||||
Declaraion of Similarity NAF-1901 | Global | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 G-K-U-SoR | Gabon,Kenya,SaudiArabia,Uganda | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 60950-CB | CB - International | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 62368-CB | CB - International | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 ACMA | ACMA - Australia, New Zealand | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 BIS | BIS - India | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 BSMI | BSMI - Taiwan | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 CE DoC | CE - European Union DoC | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 CSA | CSA - United States, Canada | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 EAC | EAC - Armenia, Belarus, Kazakhstan, Kyrgyzstan, Russia | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 FCC | FCC - United States | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 IRAM | IRAM - Argentina | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 KC | KC - South Korea | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 Morocco | Morocco | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 NOM | NOM - Mexico | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 NRCS SABS | NRCS - South Africa (Safety) | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 SONCAP | SONCAP - Nigeria | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 TBS | TBS - Tanzania | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 UKRSepro | UKRSepro - Ukraine | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 VCCI | VCCI - Japan | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
NAF-1901 UKCA DOC | UKCA -United Kingdom | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
PSU 80+ Platinum Certificates | |||||||||
NAF-1901 UKCA DOC | UKCA -United Kingdom | Platforms : AFF A400, ASA AFF A400, FAS8300, FAS8700 | |||||||
DPS-1600AB-18 B Energy Star Report | Global | PSU : X735A, X736A, X737A | |||||||
PS-2162-8F Energy Star Report | Global | PSU : X735A, X736A, X737A | |||||||
Voluntary Product Accessibility Template | |||||||||
PS-2162-8F Energy Star Report | Global | PSU : X735A, X736A, X737A | |||||||
VPAT - AFF A400, FAS8300, FAS8700 | Global | Platforms : AFF A400, FAS8300, FAS8700 |
Size, Weight, Acoustic, Power FAS8300 Single Chassis HA Pair, Ethernet Bundle
Associated Part No. | Configuration | Rack Units | Weight | Sound Power | Sound Pressure | Line Voltage Actual (Min to Max) | Amps Typical | Amps Worst | Watts Typical | Watts Worst | BTU / Hr Typical | BTU / Hr Worst |
---|---|---|---|---|---|---|---|---|---|---|---|---|
FAS8300 | ||||||||||||
FAS8300A Ethernet Bundle | FAS8300 2 PCM | 4 | 108.5 lb (49.2 kg) | 8.5 Bels | 67.2 dBA | 100 (100 to 120) | 12.09 | 15.43 | 1184 | 1512 | 4041 | 5161 |
FAS8300A Ethernet Bundle | FAS8300 2 PCM | 4 | 108.5 lb (49.2 kg) | 8.5 Bels | 67.2 dBA | 200 (200 to 240) | 6.02 | 7.5 | 1179 | 1470 | 4024 | 5017 |
FAS8300A FC Bundle | FAS8300 2 PCM | 4 | 108.5 lb (49.2 kg) | 8.5 Bels | 67.2 dBA | 100 (100 to 120) | 12.09 | 15.43 | 1184 | 1512 | 4041 | 5161 |
FAS8300A FC Bundle | FAS8300 2 PCM | 4 | 108.5 lb (49.2 kg) | 8.5 Bels | 67.2 dBA | 200 (200 to 240) | 6.02 | 7.5 | 1179 | 1470 | 4024 | 5017 |