Maximum Raw Capacity (HA): 576TB
Maximum Disk Drives: 144
Maximum Internal Drives: 24
Controller Form Factor: 4U
Max Memory: 36GB
Disk Type: NL-SAS, SAS, SATA
Disk Form Factor: 2.5", 3.5"
Host Connectivity: 16Gb Fibre Channel (FC), 10Gb Fibre Channel over Ethernet (FCoE), 1GbE, 10GbE
Storage Protocols Supported: CIFS (NAS), Fibre Channel (FC), Fibre Channel over Ethernet (FCoE), NFS (NAS), iSCSI (IP SAN)
Supported RAID: RAID 4, RAID 6 (RAID-DP)

*Available in Single or Dual Controller ('C' Cluster / 'A' Active-Active / 'HA' High-Availability). Ask for pricing with disks. Call for Details and Pricing

The NetApp FAS2500 series Hybrid storage arrays provide more value for your money than any other system in its class. Every FAS2554 hybrid storage array includes unified support for NAS or SAN workloads and can be configured as a hybrid or an all-flash system to meet specific price or performance goals.

The FAS2554 is equipped for higher capacity needs and is a great fit for mid-sized organizations, Windows applications and virtual server consolidation with multiple workloads. The FAS2554 is also ideal for customers who require I/O flexibility, cost-effective large capacity systems.

You don't need to be a storage expert to deploy and manage NetApp storage systems. The FAS2500 series offers a powerful range of technologies to help reduce complexity and increase the efficiency of your storage administrators. FAS2500 series has a 3x faster System Setup, allows you to easily manage 2-3 times more storage, and quickly tune and troubleshoot virtual server environments with ease on the fly.

FAS2554 Technical Specifications

SCALE-OUT SPECIFICATIONS
NAS/SAN Scale-Out 1-8 Nodes (4 HA Pairs)

Maximum Drives

576

Maximum Raw Capacity

2.30PB

Maximum Flash Pool

16TB

Maximum Memory

144GB

Cluster Interconnect

10GbE
PER HA PAIR SPECIFICATIONS (ACTIVE-ACTIVE DUAL CONTROLLER)
Maximum Drives 144
Maximum Raw Capacity 576
Controller Form Factor 4U/24 Drives
ECC Memory 36GB
Maximum Flash Pool 4TB
NVMEM/NVRAM 4GB
Onboard I/O: UTA 2 (8Gb FC / 16Gb FC / FCoE / 10GbE) 8
Onboard I/O: 10G Base-T N/A
Onboard I/O: GbE 4
Onboard I/O: 6Gb SAS 4
OS Version Data ONTAP 8.2.2 or Later
Storage Protocols Supported FCP, iSCSI, NFS, CIFS, FCoE
Host/Client Operating Systems Supported Windows 2000, Windows Server 2003, Windows Server 2008, Windows Server 2012, Windows XP, Linux, Oracle Solaris, AIX, HP-UX, Mac OS, VMware, ESX
ADDITIONAL TECHNICAL SPECIFICATIONS FOR SINGLE AND HA CONFIGURATIONS
Maximum Raw Capacity (HA) 576TB
Recommended Min Raw Capacity Array LUNs (GB) N/A
Absolute Min Raw Capacity Array LUNs (GB) N/A
Maximum Storage Devices (HA) 144 Disks
Max DS2246 Shelves (HA) 5
Max DS4243 Shelves (HA) 5
Max DS4246 Shelves (HA) 5
Max DS4486 Shelves (HA) N/A
Max DS14-Class Shelves (HA) N/A
Max Nodes per Cluster (NAS) Not Supported
Max Nodes per Cluster (SAN) Not Supported
Aggregate Size 32 bit (TiB) 16
Aggregate Size 64 bit (TiB) 120
Min Size for an Array LUN Aggregate (GB) N/A
Flex Volume Size 32 bit (TiB) 16
Flex Volume Size 64 bit (TiB) 60
Max Infinite Volume Data Constituent Size (TiB) Not Supported
Max Volume Count (Single) 1000
Max Array LUN Size (GB) N/A
Min Array LUN Size (GB) N/A
Min Array LUN Size - Root Volume (GB) N/A
Min Root Volume Size (Single/HA) 250GB / 250GB
Spare Core Array LUN Min Size (GB) N/A
Max RAID Groups in an Aggregate N/A
Block Size (Bytes) N/A
Chassis Height 7.05"
Chassis Width 17.70"
Chassis Depth 21.94"
Rack Units (Single/HA) 4U/4U
Operating Temperature Range 50°F to 104°F
Storage Temperature Range -40° to 158°F
Input Power Voltage 100v to 120v, 200v to 240v
Processor (Single) 1x 64-bit 2-core with HT 1.73Ghz
Memory (Single/HA) 18GB/36GB
NVRAM (Single) 1.25GB (NVMEM)
Ethernet Ports (Single) 2x RJ45 (1Gbps)
Fibre Channel Ports (Single) N/A
UTA2 Ports (Single) 4x SFP+ (16Gbps)
Expansion Slots (Single) N/A
SAS Ports (Single) 2x QSFP (6Gbps)
Max Back-End FC Loops (HA) 1
Min Version of Data ONTAP 7 N/A
Min Version of Data ONTAP 8 (both modes) 8.2.2RC1, 8.3RC1
Max Version of Data ONTAP 8 (both modes) 8.2.4, 8.3.2RC1

Ask about our NetApp Disk Shelves! We can create custom Turn-Key configurations based on your needs!


Product Specs

Storage Limits

Max # of Drives (Total) Max # of Internal Drives Max # of MSATA Drives Max # of NL-SAS Drives Max # of SAS Drives Max # of SATA Drives Max # of NVMe SSD Drives Max # of SSD Drives Max # of DS212C Shelves Max # of DS2246 Shelves Max # of DS224C Shelves Max # of DS4243 Shelves Max # of DS4246 Shelves Max # of DS4486 Shelves Max # of DS460C Shelves Max # of FS424C Shelves Max # of NS224 Shelves
144 24 - 144 144 144 - 96 9 external 5 external 5 external 5 external 1 internal + 5 external - - - -

Capacity Limits

Marketing Max Raw Capacity - Node HA Pair Cluster Effective Capacity - Node HA Pair Cluster
2088000 2088000 - 9267588 9267588 -

Core Cluster Limits

Max SVM's - NAS Max LIF's - NAS Max Connections - NAS Max Flexible Volumes - NAS Max Flexible Volumes with DPO - NAS Max Lock Manager Locked Objects Max Intercluster LIFs - Node Min Root Aggregate (MiB) - Node Min Root Aggregate (with core dump device) (MiB) Min Root Volume (GiB) - Node Min Root Volume (with core dump device) (GiB) Max IPsec Policies Max # of IPspaces Max Auditing-Enabled SVMs - Cluster
Node:-
HA Pair:-
Cluster:1024
Node:256
HA Pair:256
Cluster:1024
Node:10000
HA Pair(Non-Scalable):10000
Aggregate (Single data Agg. per Node):-
Aggregate (Multiple data Agg. per Node):-
Node:1000
HA Pair:2000
Cluster:8000
Node:600000
HA Pair:600000
Cluster:2400000
Node:-
HA Pair:-
Cluster:-
8 441245.29 - 350 - SVM:256
Cluster:1500
- 50

System Maximums and Limits

Max Nodes per Cluster (NAS / SAN) Max FabricPool Size Max FlexGroup Data Constituent Size Max Infinite Volume Data Constituent Size Max FlexGroup Data Constituent Size Min Root Volume Size NetApp Volume Encryption
44781 Not Supported 60 TiB Not Supported - 350 GiB Not Supported

Processor

Processor Model Processor Architecture Processor Speed Processor Count (Per Node) Processor Count (Per Config) Processor Cores (Per CPU) Processor Cores (Per Node) Processor Cores (Per Config)
64-bit 2-core with HT 64 bit 1.73 Ghz 1 2 2 2 4

Memory

NVRAM (Per Node) NVRAM (Per Config) NVME (Per Node) NVME (Per Config) NVMEM (Per Node) NVMEM (Per Config) RAM (Per Node) RAM (Per Config)
- - - - 1 GB 2 GB 18 GB 36 GB

Onboard Ports

Ethernet Ports Fibre Channel Ports UTA2 Ports Expansion Slots SAS Ports
4 x RJ45 (1Gb) - 8 x SFP+ (10Gb/16Gb)  [1] - 4 x QSFP (6Gb)

Physical Characteristics

Rack Units Chassis Height Chassis Width with Mounting Flanges Chassis Width without Mounting Flanges Chassis Depth with Cable Mgmt Chassis Depth without Cable Mgmt Chassis Weight
4 7.05" (17.9 cm) 19" (48.26 cm) 17.7" (44.96 cm) 23.91" (60.73 cm) 21.94" (55.74 cm) See Weights by configuration

System Clearance Dimensions

Front Clearance (Cooling) Front Clearance (Maintenance) Rear Clearance (Cooling) Rear Clearance (Maintenance)
6.03" (15.3 cm) 26" (66 cm) 16.04" (40.7 cm) 16.04" (40.7 cm)

Environmental Requirements

Operating Storage Transit Acoustic Noise Input Power Voltage
Tempature:
50 to 104 deg F - 10 to 40 deg C

Humidity:
20 to 80 %

Altitude:
Up to 10000.0 ft - Up to 3048.0 m
Tempature:
-40 to 158 deg F - -40 to 70 deg C

Humidity:
5 to 95 %

Altitude:
Up to 40000.0 ft - Up to 12192.0 m
Tempature:
-40 to 158 deg F - -40 to 70 deg C

Humidity:
5 to 95 %

Altitude:
Up to 39989.8 ft - Up to 12192 m
Sound Power:
6.9 bels

Sound Pressure:
49.6 dBA
100 to 120 200 to 240

Storage OS Requirements

Full OS Matrix Recommended Version Minimum OS Maximum OS
View Full OS Report Below 9.8P12, 9.8P13 9.8RC1 9.8P13

Storage and Firmware

Full Firmware Matrix BIOS BMC
Full Firmware Report Below 8.3* -

Product Standards Compliance

Full Compliance and Certificates Report Cert. EMC/EMI Cert. Safety Service Processor Firmware Cert. Safety/EMC/EMI Cert. Safety/EMC/EMI/RoHS Standard Safety/EMC/EMI Standard Safety
Compliance and Certificates Report Below AMCA, FCC, ICES, KC, Morocco, VCCI BIS, CB, CSA, G_K_U-SoR, IRAM, NOM, NRCS, SONCAP, TBS 2.12, 2.11* EAC, UKRSEPRO BSMI, CE DoC CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, FCC Part 15 Class A, ICES-3 ANSI/UL 60950-1, CNS 14336, CSA 60950, EN60825-1, EN60950-1, IEC60825-1

NFS Cluster Limits

Max Export Policies - Cluster Max Export Rules - Cluster Max NFSv4 Access Control Entries Max Client Objects Max pNFS objects
24000 200000 1024 Node:10000
HA Pair:10000
Node:524288
HA Pair:524288
Cluster:2097152

WAFL Cluster Limits - All Maximums

Size 64-bit Aggregate (TiB) Size 64-bit Volume (TiB) File size 64-bit Volume (TiB) Volume Snapshot Copies Character length for Snapshot copy names Hard links - File inodes/files - Volume Number of qtrees Concurrent DataMotion for Volumes ops
120 60 16 Volume:1023
Node:1023000
HA Pair:2046000
255 100000 2000000000 Volume:4995
Node:100000
HA Pair:200000
Cluster:400000
Node:8
HA Pair:16

Quality of Service Cluster Limits

Max Policy Groups - Cluster Max QoS User Workloads - Cluster
12000 12000

SAN Cluster Limits - All Maximums

# of storage virtual machines (SVMs) - SAN # of flexible volumes - SAN # of Flexible Vol with DPO - # of LUNs LUN mappings LUN size (TiB) - LUN FC queue depth available # of SAN Hosts (ITNs) # of LIFS - iSCSI # of LIFS - FCP # of igroups # of Initiators # of Portsets # of iSCSI sessions
Node:125
HA Pair:250
Cluster:1000
Single data Aggregate:-
Multiple data Aggregates:-
Node:1000
HA Pair:2000
Cluster:8000
Node:-
HA Pair:-
Cluster:-
Valume:1024
Node:2048
HA Pair:4096
Cluster:16384
Node:2048
HA Pair:4096
Cluster:16384
16 2048 Port:512
Node:2048
HA Pair:4096
Cluster:16384
Port:32
Portset:32
Node:256
HA Pair:512
Cluster:2048
Port:32
Portset:32
Node:512
HA Pair:1024
Cluster:4096
Node:512
HA Pair:1024
Cluster:4096
igroup:256
Node:1024
HA Pair:2048
Cluster:8192
Node:512
HA Pair:1024
Cluster:4096
Node:2048
HA Pair:4096
Cluster:16384

CIFS Cluster Limits - All Maximums

# of Connected Shares # of Regular Shares # of Open files # of Local users - Cluster # of Local groups - Cluster # of Local group members - Cluster
Node:400000
HA Pair:400000
Node:-
HA Pair:-
Cluster:60000
Connection:65536
Node:300000
HA Pair:300000
5000 10000 30000

Data Protection Cluster Limits - All Maximums

NDMP Sessions Data Protection Mirrors Load Sharing Mirrors - NAS SVM Concurrent Snap Mirror / SnapVault transfers - Node DP Mirror fan-out - Volume LS Mirror fan-out - NAS SVM # of Clusters that can be peered - Cluster Volumes, SnapMirror relationship SnapMirror Synchronous relationships # of Consistency Groups in SM-BC relationships # of Constituent Volumes in SM-BC relationships Flexible Volumes in SVM DR SVM Disaster recovery - Cluster # of Concurrent SVM Migration - Cluster # of Volumes with SVM Migration - SVM # of Cluster for SVM Migration - Cluster
Node:20
HA Pair (Non-Scalable):20
Volume:1
Node:1000
HA Pair:2000
Cluster:8000
2 100 8 2 255 FlexGroup:200
FlexGroup-Node:50
Node:500
HA Pair:1000
Cluster:6000
Volume:1
Node:40
HA Pair (Non-Scalable):40
HA Pair (Non-Scalable):- Consistency group:-
HA Pair (Non-Scalable):-
SVM:300
HA Pair:1000
32 - - -

FlexCache Cluster Limits - All Maximums Cache

Degree of fan-out - Origin Origin Volumes Constituent Volumes Volumes Origin ConstituentVolumes
100 Node:100
HA Pair:200
Node:800
HA Pair:1600
Node:100
HA Pair:200
Node:800
HA Pair:1600

S3 Cluster Limits -

Max # of Buckets Max # of Objects - Bucket Max # of Users Max Size of the Bucket (PB) - Vserver
Vserver:12000
Cluster:12000
400000000000 Vserver:4000
Cluster:96000
20

Footnotes -

Notes ID Notes Description
[1] The onboard UTA2 ports can be configured as FC Target/Initiator or CNA (FCoE target/Ethernet). The UTA2 ports are based on a dual port ASIC and both ports on each ASIC must be set to the same mode (enforced by Data ONTAP). Install X6589-R6 10GbE SFP+ modules or approved copper twinax cables when using in CNA (FCoE target/Ethernet) mode. Install X6596-R6 16Gb FC SFP+ module when using in FC Target/Initiator mode.

Platform LED for FAS2554HA

LED Label LED Name Type Status Indicator Description
1 Chassis Attention LED, front - On Amber The system halted or a fault occurred in the chassis.
- - - Off The system is operating normally.
2 Chassis Power Config - On Green At least one of the two PSUs is delivering power to the system.
- - - Off Neither PSU is delivering power to the system.
Back View
0a Port SAS Onboard Config Link Green Link is established on at least one external SAS lane
- - - Off No link is established on any external SAS lane
0b Port SAS Onboard Config Link Green Link is established on at least one external SAS lane
- - - Off No link is established on any external SAS lane
e0a Port Ethernet Config Port Activity Blinking amber Traffic is flowing over the connection
- - - Off No traffic is flowing over the connection.
- - Port Link Green A connection is established on the port
- - - Off No connection is established on the port.
e0b Port Ethernet Config Port Activity Blinking amber Traffic is flowing over the connection
- - - Off No traffic is flowing over the connection.
- - Port Link Green A connection is established on the port
- - - Off No connection is established on the port.
e0d/0d FAS255x UTA2 Port Config (Ethernet personality) Activity Blinking amber Traffic is flowing over the connection
- - - Off No traffic is flowing over the connection.
- - Link Green A connection is established to the port.
- - - Off No connection is established on the port.
e0d/0d FAS255x UTA2 Port Config (FC personality) Activity Blinking amber Traffic is flowing over the connection
- - - Off No traffic is flowing over the connection.
- - Link Green A connection is established to the port.
- - - Off No connection is established on the port.
e0e/0e FAS255x UTA2 Port Config (Ethernet personality) Activity Blinking amber Traffic is flowing over the connection
- - - Off No traffic is flowing over the connection.
- - Link Green A connection is established to the port.
- - - Off No connection is established on the port.
e0e/0e FAS255x UTA2 Port Config (FC personality) Activity Blinking amber Traffic is flowing over the connection
- - - Off No traffic is flowing over the connection.
- - Link Green A connection is established to the port.
- - - Off No connection is established on the port.
e0f/0f FAS255x UTA2 Port Config (Ethernet personality) Activity Blinking amber Traffic is flowing over the connection
- - - Off No traffic is flowing over the connection.
- - Link Green A connection is established to the port.
- - - Off No connection is established on the port.
e0f/0f FAS255x UTA2 Port Config (FC personality) Activity Blinking amber Traffic is flowing over the connection
- - - Off No traffic is flowing over the connection.
- - Link Green A connection is established to the port.
- - - Off No connection is established on the port.
e0M/SP Port Remote Management Config - Blinking amber Traffic is flowing over the connection.
- - - Green A link is established between the port and some upstream device.
- - - Off No link is established.
- - - Off No traffic is flowing over the connection.
e0P Port Private management Config - Blinking amber Traffic is flowing over the connection.
- - - Green A link is established between the port and a downstream disk shelf.
- - - Off No link is established.

Supported Shelves Drives for FAS2554HA

Part No.Capacity RPM Drive Type Encryption Root-Data Partitioning Root-Data-Data Partitioning Storage Pool Partitioning Max Drive Count FlexArray
FAS2554HA Internal Drives [4]
X302A-R5 1TB 7.2K SATA No Yes No No 24 No
X306A-R5 2TB 7.2K SATA No Yes No No 24 No
X308A-R5 3TB 7.2K SATA No Yes No No 24 No
X315A-R6 [1] [2] 4TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 24 No
X316A-R6 6TB 7.2K NL-SAS No Yes No No 24 No
X317A [1] [3] 6TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 24 No
X318A-R6 8TB 7.2K NL-SAS No Yes No No 24 No
X322A [1] 10TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 24 No
X336A-R6 4TB 7.2K NL-SAS No Yes No No 24 No
X363A-R6 3.84TB N/A SSD No No No Yes 24 No
X366A-R6 [1] 1.6TB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 24 No
X374A 960GB N/A SSD No No No Yes 24 No
X380A 10TB 7.2K NL-SAS No Yes No No 24 No
X448A-R6 200GB N/A SSD No No No Yes 24 No
X449A-R6 800GB N/A SSD No No No Yes 24 No
X477A-R6 4TB 7.2K NL-SAS No Yes No No 24 No
X488A-R5 900GB 10K SAS No Yes No No 24 No
X489A-R6 1.2TB 10K SAS No Yes No No 24 No
X490A-R6 1.8TB 10K SAS No Yes No No 24 No
X575A-R6 400GB N/A SSD No No No Yes 24 No
X576A-R6 1.6TB N/A SSD No No No Yes 24 No
X577A-R6 [1] [2] 800GB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 24 No
DS212C with IOM12 / IOM12 / IOM12B / IOM12B shelf modules
X363A-R6 3.84TB N/A SSD No No No Yes 72 No
X366A-R6 [1] 1.6TB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 72 No
X374A 960GB N/A SSD No No No Yes 72 No
X448A-R6 200GB N/A SSD No No No Yes 72 No
X449A-R6 800GB N/A SSD No No No Yes 72 No
X575A-R6 400GB N/A SSD No No No Yes 72 No
X576A-R6 1.6TB N/A SSD No No No Yes 72 No
X577A-R6 [1] [2] 800GB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 72 No
X302A-R5 1TB 7.2K SATA No Yes No No 108 No
X306A-R5 2TB 7.2K SATA No Yes No No 108 No
X308A-R5 3TB 7.2K SATA No Yes No No 108 No
X315A-R6 [1] [2] 4TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 108 No
X317A [1] [3] 6TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 108 No
X318A-R6 8TB 7.2K NL-SAS No Yes No No 108 No
X322A [1] 10TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 108 No
X336A-R6 4TB 7.2K NL-SAS No Yes No No 108 No
X339A 2TB 7.2K NL-SAS No Yes No No 108 No
X380A 10TB 7.2K NL-SAS No Yes No No 108 No
X388A 16TB 7.2K NL-SAS No Yes No No 108 No
X477A-R6 4TB 7.2K NL-SAS No Yes No No 108 No
X488A-R5 900GB 10K SAS No Yes No No 108 No
X489A-R6 1.2TB 10K SAS No Yes No No 108 No
X490A-R6 1.8TB 10K SAS No Yes No No 108 No
DS224C with IOM12 / IOM12 / IOM12B / IOM12B shelf modules
X319A 7.6TB N/A SSD No No Yes No 72 No
X356A-R6 3.84TB N/A SSD No No Yes Yes 72 No
X357A 3.84TB N/A SSD No No Yes Yes 72 No
X358A [1] 3.84TB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 72 No
X365A-R6 [1] 1.6TB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 72 No
X371A 960GB N/A SSD No No Yes Yes 72 No
X386A [1] 960GB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 96 No
X438A-R6 400GB N/A SSD No No Yes Yes 72 No
X439A-R6 1.6TB N/A SSD No No Yes Yes 72 No
X440A-R6 [1] [2] 800GB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 72 No
X440B-R6 [1] 800GB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 72 No
X446B-R6 200GB N/A SSD No No No Yes 72 No
X447A-R6 800GB N/A SSD No No Yes Yes 72 No
X670A 15.3TB N/A SSD No No Yes No 72 No
X341A-R6 900GB 10K SAS No Yes No No 120 No
X342A-R6 1.2TB 10K SAS No Yes No No 120 No
X343A-R6 1.8TB 10K SAS No Yes No No 120 No
X416A-R5 [1] [2] 600GB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X417A-R6 [1] [2] 900GB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X421A-R5 450GB 10K SAS No Yes No No 120 No
X422A-R5 600GB 10K SAS No Yes No No 120 No
X423A-R5 900GB 10K SAS No Yes No No 120 No
X425A-R6 1.2TB 10K SAS No Yes No No 120 No
X426A-R6 1.8TB 10K SAS No Yes No No 120 No
X427A [1] 1.8TB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X427B-R6 [1] 1.8TB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
DS2246 [4] with IOM6 / IOM12 / IOM12 / IOM6 / IOM12B / IOM12B shelf modules
X356A-R6 3.84TB N/A SSD No No Yes Yes 72 No
X357A 3.84TB N/A SSD No No Yes Yes 72 No
X358A [1] 3.84TB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 72 No
X365A-R6 [1] 1.6TB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 72 No
X371A 960GB N/A SSD No No Yes Yes 72 No
X438A-R6 400GB N/A SSD No No Yes Yes 72 No
X439A-R6 1.6TB N/A SSD No No Yes Yes 72 No
X440A-R6 [1] [2] 800GB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 72 No
X440B-R6 [1] 800GB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 72 No
X446B-R6 200GB N/A SSD No No No Yes 72 No
X447A-R6 800GB N/A SSD No No Yes Yes 72 No
X341A-R6 900GB 10K SAS No Yes No No 120 No
X342A-R6 1.2TB 10K SAS No Yes No No 120 No
X343A-R6 1.8TB 10K SAS No Yes No No 120 No
X416A-R5 [1] [2] 600GB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X417A-R6 [1] [2] 900GB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X421A-R5 450GB 10K SAS No Yes No No 120 No
X422A-R5 600GB 10K SAS No Yes No No 120 No
X423A-R5 900GB 10K SAS No Yes No No 120 No
X425A-R6 1.2TB 10K SAS No Yes No No 120 No
X426A-R6 1.8TB 10K SAS No Yes No No 120 No
X427A [1] 1.8TB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X427B-R6 [1] 1.8TB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
DS4246 [4] with IOM6 / IOM12 / IOM6 / IOM12 / IOM12B / IOM12B shelf modules
X363A-R6 3.84TB N/A SSD No No No Yes 72 No
X366A-R6 [1] 1.6TB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 72 No
X374A 960GB N/A SSD No No No Yes 72 No
X448A-R6 200GB N/A SSD No No No Yes 72 No
X449A-R6 800GB N/A SSD No No No Yes 72 No
X575A-R6 400GB N/A SSD No No No Yes 72 No
X576A-R6 1.6TB N/A SSD No No No Yes 72 No
X577A-R6 [1] [2] 800GB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 72 No
X302A-R5 1TB 7.2K SATA No Yes No No 120 No
X306A-R5 2TB 7.2K SATA No Yes No No 120 No
X308A-R5 3TB 7.2K SATA No Yes No No 120 No
X315A-R6 [1] [2] 4TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X316A-R6 6TB 7.2K NL-SAS No Yes No No 120 No
X317A [1] [3] 6TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X318A-R6 8TB 7.2K NL-SAS No Yes No No 120 No
X322A [1] 10TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X336A-R6 4TB 7.2K NL-SAS No Yes No No 120 No
X380A 10TB 7.2K NL-SAS No Yes No No 120 No
X477A-R6 4TB 7.2K NL-SAS No Yes No No 120 No
X488A-R5 900GB 10K SAS No Yes No No 120 No
X489A-R6 1.2TB 10K SAS No Yes No No 120 No
X490A-R6 1.8TB 10K SAS No Yes No No 120 No
DS4243 with IOM6 shelf modules
X302A-R5 1TB 7.2K SATA No No No No 120 No
X306A-R5 2TB 7.2K SATA No No No No 120 No
X308A-R5 3TB 7.2K SATA No No No No 120 No
Footnote:
[1] Mixing NSE drives or shelves with any other type of encrypting or non-encrypting drives or shelves across a stand-alone platform or high-availability (HA) pair is not supported.
[2] In Flash Pool NSE SSD drives can only be used with NSE HDD drives.
[3] Mixing encrypted with unencrypted drives or shelves across a stand-alone platform or high-availability (HA) pair is not supported.
[4] Total number of SSD drives cannot exceed 96 drives on the FAS255x. However, other drive types (SAS/SATA/NL-SAS) can be added to these system to achieve the maximum drive count of 144 drives.

Supported RAID Configurations - FAS2554HA

Drive Type Drive Capacity Min Drive Capacity Max Minimum Default Maximum
Data Aggregate
RAID4
NL-SAS 0 TB 8 TB 3 7 7
SAS 0 TB 5.999 TB 3 8 14
SATA 0 TB 5.999 TB 3 7 7
SSD 0 TB 15.3 TB 3 8 14
RAID-DP
NL-SAS 0 TB 5.999 TB 5 14 20
NL-SAS 6 TB 8 TB 5 14 14
SAS 0 TB 5.999 TB 5 16 28
SATA 0 TB 5.999 TB 5 14 20
SSD 0 TB 15.3 TB 5 24 28
RAID-TEC
NL-SAS 0 TB 16 TB 7 21 29
SAS 0 TB 8 TB 7 24 29
SATA 0 TB 8 TB 7 21 29
SSD 0 TB 15.3 TB 7 25 29
Root Aggregate
RAID4
NL-SAS 0 TB 8 TB 2 - 7
SAS 0 TB 5.999 TB 2 - 14
SATA 0 TB 5.999 TB 2 - 7
SSD 0 TB 15.3 TB 2 - 14
RAID-DP
NL-SAS 0 TB 5.999 TB 3 - 20
NL-SAS 6 TB 16 TB 3[1] - 14
SAS 0 TB 5.999 TB 3[2] - 28
SATA 0 TB 5.999 TB 3[2] - 20
SSD 0 TB 15.3 TB 3 - 28
RAID-TEC
NL-SAS 0 TB 16 TB 7 - 29
SAS 0 TB 8 TB 7 - 29
SATA 0 TB 8 TB 7 - 29
SSD 0 TB 15.3 TB 7 - 29
Footnote:
[1] RAID-DP is supported with 10TB NL-SAS drives only if HA pair has 10-14 drives
[2] The minimum number of disks in a RAID-DP group is three: at least one data disk, one regular parity disk, and one double-parity (dParity) disk. However, for non-root aggregates with only one RAID group, you must have at least 5 disks (three data disks and two parity disks).

No Supported Cards

Priority Category Bus Type Mktg Part No. Mfg Part No Description Plug Type Optical Module Included? Cables Supported Protocol(s) Min ONTAP Max Qty [1] Priority Slot Assignment

Supported Connections for FAS2554HA

Configuration Type Port Configuration Image Cluster Ports per Node Switch Ports per Node
Cluster Interconnect
2-node Switchless Cluster Default, Maximum, Recommended View Image 2 None
2-node Switchless Cluster Minimum View Image 1 None
Switched 10GbE Interconnect Default, Maximum, Recommended View Image 2 2
Switched 10GbE Interconnect Minimum View Image 1 1
Switched 40GbE Interconnect (10GbE breakout) Maximum, Recommended View Image 2 1

Platform Mixing Rules: FAS2554HA

Platform Configuration Type Maximum Nodes (NAS) [1] Maximum Nodes (SAN) [1] Min ONTAP Version for Platform Mixing
FAS - Current Configuration(s)
FAS2720A 10GBASE-T 8 Nodes 8 Nodes 9.4RC1
FAS2720A UTA2 8 Nodes 8 Nodes 9.4RC1
FAS2750A 10GBASE-T 8 Nodes 8 Nodes 9.4RC1
FAS2750A UTA2 8 Nodes 8 Nodes 9.4RC1
FAS2554HAA 8 Nodes 8 Nodes 9.8RC1
FAS9000A 8 Nodes 8 Nodes 9.1
AllFlashFAS - Current Configuration(s)
AFF A250A 8 Nodes 8 Nodes 9.8RC1
AFF A700A 8 Nodes 8 Nodes 9.1
AFF C190A 10GBASE-T 8 Nodes 8 Nodes 9.6RC2
AFF C190A UTA2 8 Nodes 8 Nodes 9.6RC2
FAS - Legacy EOA Configuration(s)
FAS2520HA 8 Nodes 8 Nodes 9.0RC1
FAS2552HA 8 Nodes 8 Nodes 9.0RC1
FAS2554HA 8 Nodes 8 Nodes 9.0RC1
FAS2620A 8 Nodes 8 Nodes 9.1
FAS2650A 8 Nodes 8 Nodes 9.1RC1
FAS8020A 8 Nodes 8 Nodes 9.0RC1
FAS8040A 8 Nodes 8 Nodes 9.1
FAS8060A 8 Nodes 8 Nodes 9.1
FAS8060AE 8 Nodes 8 Nodes 9.1
FAS8080AE EX 8 Nodes 8 Nodes 9.1
FAS8200A 8 Nodes 8 Nodes 9.1RC1
AllFlashFAS - Legacy EOA Configuration(s)
AFF A200A 8 Nodes 8 Nodes 9.1RC2
AFF A220A 10GBASE-T 8 Nodes 8 Nodes 9.4RC1
AFF A220A UTA2 8 Nodes 8 Nodes 9.4RC1
AFF A300A 8 Nodes 8 Nodes 9.1RC1
AFF A320A 8 Nodes 8 Nodes 9.6RC2
AFF A700s 8 Nodes 8 Nodes 9.1
AFF8020A 8 Nodes 8 Nodes 9.0RC1
AFF8040A 8 Nodes 8 Nodes 9.0RC1
AFF8060A 8 Nodes 8 Nodes 9.1
AFF8060AE 8 Nodes 8 Nodes 9.1
AFF8080A EX 8 Nodes 8 Nodes 9.1
AFF8080AE EX 8 Nodes 8 Nodes 9.1
Footnote:
[1] Maximum number of nodes within a cluster is determined by platform which supports the fewest number of nodes

Product Standard Compliance - FAS2554HA

Standard Description
Certifications EMC/EMI
AMCA Australia and New Zealand (EMC covered by ACMA DoC)
FCC Federal Communications Commission (EMI Declaration of Conformity covering United States and Canada)
ICES ICES
KC Korea Communications Commission (EMC certificate for South Korea)
Morocco Morocco Declaration of Conformity
VCCI EMI Certificate for Japan
Certifications safety
BIS Bureau of Indian Standard (Safety cert for India)
CB Certificate Body issued safety certificate covering International
CSA Canadian Standards Association issued Safety certificate covering North America
G_K_U-SoR Safety certificate for Gabon, Kenya and Uganda
IRAM Instituto Argentino de Normalización y Certificación (safety certificate for Argentina)
NOM Norma Oficial Mexicana (Safety cert for Mexico)
NRCS National Regulator for Compulsory Specifications (Safety cert for South Africa)
SONCAP Standards Organisation of Nigeria Conformity Assessment Programme (Safety cert for Nigeria)
TBS Tanzanian Bureau of Standards (Safety certificate for Tanzania)
Certifications Safety/EMC/EMI
EAC Euro Asia Conformity (EMC and Safety Cert) covering (Russia, Kazakhstan, Belarus, Armenia, Kyrgyzstan Countries)
UKRSEPRO EMC/Safety certificate for Ukraine
Certifications Safety/EMC/EMI/RoHS
BSMI Certificate for Taiwan
CE DoC European Union Declaration of Conformity
Standards EMC/EMI
CISPR 22 EMI
EN55022 EMC Standard fo European Union
EN55024 EMC Standard fo European Union
EN61000-3-2 EMC Standard for European Union
EN61000-3-3 EMC Standard for European Union
FCC Part 15 Class A EMI standard for United States
ICES-3 EMI Stardard for Canada
Standards Safety
ANSI/UL 60950-1 ANSI/UL 60950-1
CNS 14336 Safety Standard for Taiwan
CSA 60950 CSA 60950
EN60825-1 Laser Safety standard for European Union
EN60950-1 EN60950-1
IEC60825-1 Laser Safety Standard for International
Certifications EMC/EMI
AMCA Australia and New Zealand (EMC covered by ACMA DoC)
FCC Federal Communications Commission (EMI Declaration of Conformity covering United States and Canada)
ICES ICES
KC Korea Communications Commission (EMC certificate for South Korea)
Morocco Morocco Declaration of Conformity
VCCI EMI Certificate for Japan
Certifications safety
BIS Bureau of Indian Standard (Safety cert for India)
CB Certificate Body issued safety certificate covering International
CSA Canadian Standards Association issued Safety certificate covering North America
G_K_U-SoR Safety certificate for Gabon, Kenya and Uganda
IRAM Instituto Argentino de Normalización y Certificación (safety certificate for Argentina)
NOM Norma Oficial Mexicana (Safety cert for Mexico)
NRCS National Regulator for Compulsory Specifications (Safety cert for South Africa)
SONCAP Standards Organisation of Nigeria Conformity Assessment Programme (Safety cert for Nigeria)
TBS Tanzanian Bureau of Standards (Safety certificate for Tanzania)
Certifications Safety/EMC/EMI
EAC Euro Asia Conformity (EMC and Safety Cert) covering (Russia, Kazakhstan, Belarus, Armenia, Kyrgyzstan Countries)
UKRSEPRO EMC/Safety certificate for Ukraine
Certifications Safety/EMC/EMI/RoHS
BSMI Certificate for Taiwan
CE DoC European Union Declaration of Conformity
Standards EMC/EMI
CISPR 22 EMI
EN55022 EMC Standard fo European Union
EN55024 EMC Standard fo European Union
EN61000-3-2 EMC Standard for European Union
EN61000-3-3 EMC Standard for European Union
FCC Part 15 Class A EMI standard for United States
ICES-3 EMI Stardard for Canada
Standards Safety
ANSI/UL 60950-1 ANSI/UL 60950-1
CNS 14336 Safety Standard for Taiwan
CSA 60950 CSA 60950
EN60825-1 Laser Safety standard for European Union
EN60950-1 EN60950-1
IEC60825-1 Laser Safety Standard for International

Supported OS Version - FAS2554HA

OS Major Version Supported OS Version Supported Milestones Recommend Version
Currently Supported OS
ONTAP 9.8 9.8P13, 9.8P12, 9.8P11, 9.8P10, 9.8P9, 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4, 9.8P3, 9.8P2, 9.8P1, 9.8, 9.8RC1 End of Full Support: 31-Dec-2023
End of Limited Support: 31-Dec-2025
End of Self-Service Support: 31-Dec-2028
9.8P13, 9.8P12
ONTAP 9.7 9.7P19, 9.7P18, 9.7P17, 9.7P16, 9.7P15, 9.7P14, 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 End of Full Support: 31-Jan-2023
End of Limited Support: 31-Jan-2025
End of Self-Service Support: 31-Jan-2028
9.7P19
EOS OS
ONTAP 9.7 9.7P19, 9.7P18, 9.7P17, 9.7P16, 9.7P15, 9.7P14, 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 End of Full Support: 31-Jan-2023
End of Limited Support: 31-Jan-2025
End of Self-Service Support: 31-Jan-2028
9.7P19
ONTAP 9.6 9.6P18, 9.6P17, 9.6P16, 9.6P15, 9.6P14, 9.6P13, 9.6P12, 9.6P11, 9.6P10, 9.6P9, 9.6P8, 9.6P7, 9.6P6, 9.6P5, 9.6P4, 9.6P3, 9.6P2, 9.6P1, 9.6, 9.6RC2, 9.6RC1 End of Full Support: 30-Jun-2022
End of Limited Support: 30-Jun-2024
End of Self-Service Support: 30-Jun-2027
9.6P18
ONTAP 9.5 9.5P19, 9.5P18, 9.5P17, 9.5P16, 9.5P15, 9.5P14, 9.5P13, 9.5P12, 9.5P11, 9.5P10, 9.5P9, 9.5P8, 9.5P7, 9.5P6, 9.5P5, 9.5P4, 9.5P3, 9.5P2, 9.5P1, 9.5, 9.5RC1 End of Full Support: 31-Jan-2022
End of Limited Support: 31-Jan-2024
End of Self-Service Support: 31-Jan-2027
9.5P19
ONTAP 9.4 9.4P8, 9.4P7, 9.4P6, 9.4P5, 9.4P4, 9.4P3, 9.4P2, 9.4P1, 9.4, 9.4RC1 End of Full Support: 30-Jun-2019
End of Limited Support: 30-Jun-2021
End of Self-Service Support: 30-Jun-2024
9.4P8
Clustered Data ONTAP 8.3 8.3.2P12, 8.3.2P11, 8.3.2P10, 8.3.2P9, 8.3.2P8, 8.3.2P7, 8.3.2P6, 8.3.2P5, 8.3.2P4, 8.3.2P3, 8.3.2P2, 8.3.2P1, 8.3.2, 8.3.2RC2, 8.3.2RC1, 8.3.1P2, 8.3.1P1, 8.3.1, 8.3.1RC1, 8.3P2, 8.3P1, 8.3, 8.3RC2, 8.3RC1 End of Full Support: 31-Oct-2017
End of Limited Support: 30-Apr-2019
End of Self-Service Support: 30-Apr-2022
8.3.2P12
ONTAP 9.3 9.3P21, 9.3P20, 9.3P19, 9.3P18, 9.3P17, 9.3P16, 9.3P15, 9.3P14, 9.3P13, 9.3P12, 9.3P11, 9.3P10, 9.3P9, 9.3P8, 9.3P7, 9.3P6, 9.3P5, 9.3P4, 9.3P3, 9.3P2, 9.3P1, 9.3, 9.3RC1 End of Full Support: 31-Jan-2021
End of Limited Support: 31-Jan-2023
End of Self-Service Support: 31-Jan-2026
9.3P21
Clustered Data ONTAP 8.2 8.2.4P6, 8.2.4P5, 8.2.4P4, 8.2.4P3, 8.2.4P2, 8.2.4P1, 8.2.4, 8.2.3P6, 8.2.3P5, 8.2.3P4, 8.2.3P3, 8.2.3P2, 8.2.3P1, 8.2.3, 8.2.2P2, 8.2.2P1, 8.2.2, 8.2.2RC2, 8.2.2RC1 End of Full Support: 31-Jul-2017
End of Limited Support: 31-Jan-2019
End of Self-Service Support: 31-Jan-2022
8.2.4P6
7-Mode 8.2 8.2.5P5, 8.2.5P4, 8.2.5P3, 8.2.5P2, 8.2.5P1, 8.2.5, 8.2.4P6, 8.2.4P5, 8.2.4P4, 8.2.4P3, 8.2.4P2, 8.2.4P1, 8.2.4, 8.2.3P6, 8.2.3P5, 8.2.3P4, 8.2.3P3, 8.2.3P2, 8.2.3P1, 8.2.3, 8.2.2, 8.2.2RC2, 8.2.2RC1 End of Full Support: 31-Dec-2020
End of Limited Support: 31-Dec-2022
End of Self-Service Support: 31-Dec-2025
8.2.5P5
ONTAP 9.2 9.2P4, 9.2P3, 9.2P2, 9.2P1, 9.2, 9.2RC1 End of Full Support: 31-Jul-2018
End of Limited Support: 31-Jul-2020
End of Self-Service Support: 31-Jul-2023
9.2P4
ONTAP 9.1 9.1P20, 9.1P19, 9.1P18, 9.1P17, 9.1P16, 9.1P15, 9.1P14, 9.1P13, 9.1P12, 9.1P11, 9.1P10, 9.1P9, 9.1P8, 9.1P7, 9.1P6, 9.1P5, 9.1P3, 9.1P2, 9.1P1, 9.1, 9.1RC2, 9.1RC1 End of Full Support: 31-Jan-2020
End of Limited Support: 31-Jan-2022
End of Self-Service Support: 31-Jan-2025
9.1P20
Definitions:
[1]End of Full Support: The date marking the end of Full Support for a particular feature version of a NetApp system software and the beginning of Limited Support. Abbreviated as EOES.
[2]End of Limited Support: The date marking the end of Limited Support for a particular feature version of a product and transition to Self-Service Support. Abbreviated as EOVS.
[3]End of Self-Service Support: NetApp does not provide support for a version of a software product, but related documentation is still available on the NetApp Support Site. NetApp customers are expected to utilize documentation to resolve issues.

Supported Power Cords for FAS2554HA

Marketing Part No.End 1 / End 2LengthDescription
Non-Cabinet Power Cords
X800B-R6 CEE 7/7 (Schuko) / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Cont Europe/Korea,10A/250V
X800C-R6 BS1363 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,UK/Ireland,10A/250V
X800D-R6 JIS-C-8303 / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,Japan,15A/125V
X800E-R6 NEMA 5-15P / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,North America,15A/125V
X800F-R6 AS/NZS 3112 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Aus/NZ,10A/250V
X800G-R6 SEV 1011 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Switzerland,10A/250V
X800H-R6 IRAM 2073 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Argentina,10A/250V
X800I-R6 GB2099 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,China,10A/250V
X800J-R6 DHCR107-2-D1 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Demark,10A/250V
X800K-R6 SANS 164-1 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,India/S.Africa,10A/250V
X800L-R6 SI32 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Israel,10A/250V
X800M-R6 CEI 23-16 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Italy,10A/250V
X800P-R6 NEMA 6-15P / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,North America,15A/250V
X800T-R6 CNS 10917-3 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Taiwan,BSMI,15A/125V
X800VB-R6 NBR14136 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Brazil,10A/250V
X800W-R6 CNS10917/CNS690 / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,Taiwan,10A/250V
X800Y-R6 JIS-C-830 / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,Japan,15A/250V
In-Cabinet Power Cords
X1558A-R6 IEC60320-C14 / IEC60320-C13 1.20 m Pwr Cord,In-Cabinet,48-In,C13-C14,10A/250V
X800-42U-35 IEC60320-C14 / IEC60320-C13 0.89 m Pwr Cord,In-Cabinet,C13-C14,35-inch
X800-42U-43 IEC60320-C14 / IEC60320-C13 1.09 m Pwr Cord,In-Cabinet,C13-C14,43-inch
X800-42U-64 IEC60320-C14 / IEC60320-C13 1.63 m Pwr Cord,In-Cabinet,C13-C14,64-inch
X800-42U-R6 IEC60320-C14 / IEC60320-C13 0.68 m Pwr Cord,In-Cabinet,27-In,C13-C14,10A/250V

Onboard Ports Configuration: FAS2554HA

Port Address Description Supported Protocols Port Icon Port Type
0a Serial-Attached SCSI SAS 3/6 Gb Circle QSFP
0b Serial-Attached SCSI SAS 3/6 Gb Square QSFP
e0a Ethernet Ethernet 10/100/1000 Mb Ethernet RJ45
e0b Ethernet Ethernet 10/100/1000 Mb Ethernet RJ45
e0c/0c [1] Unified Target Adapter 2 Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb Ethernet/Fibre Channel SFP+
e0d/0d [1] Unified Target Adapter 2 Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb Ethernet/Fibre Channel SFP+
e0e/0e [1] Unified Target Adapter 2 Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb Ethernet/Fibre Channel SFP+
e0f/0f [1] Unified Target Adapter 2 Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb Ethernet/Fibre Channel SFP+
e0M/SP Management Ethernet 10/100/1000 Mb Wrench RJ45
e0P Private Management Ethernet 10/100/1000 Mb Wrench w/Padlock RJ45
Serial Interface Icon Serial Console RS-232 9600bps Serial Interface RJ45
Footnote:
[1] Connecting tape drives or tape libraries to the FC or UTA2 ports requires the use of a FC switch.

Supported Platform Configurations - FAS2554HA

Platform Configuration Description Chassis Configuration Chassis Count Controller Count (per chassis) IOXM Count (per chassis) Rack Units (Per System) Weight (Per Chassis) Min ONTAP
Stand Alone
FAS2554 FAS2554 Single Node Cb 1 1 0 4 54.01 lb (24.5 kg) 9.0RC1, 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1
HA Pair
FAS2554HA FAS2554 Single Chassis HA Pair CC 1 2 0 4 59.30 lb (26.9 kg) 9.0RC1, 9.1RC1, 9.2RC1, 9.3RC1, 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1

Platform Memory Specifications - FAS2554HA

Part Number Description Mfg Part Number Non-Volatile Qty Capacity (GB) NVRAM/NVMEM Used Capacity (GB) RAM Used Capacity (GB)
X3221A-R6 DIMM, 16GB, DD3-800 107-00124 no 2 16 - 36
X3220A-R6 DIMM, 2GB, DD3-800, LOW IDD6 107-00165 yes 2 2 2.5 -

Supported Rail Kit for FAS2554HA

Marketing Part No.Manufacturing Part No.Description
NetApp System Cabinet Rail Kits
X877B-R6 111-00596 Rail Kit II, NetApp Cabinet, R6
X8783A-R6 111-01110 Rail Kit III, NetApp Cabinet, R6
Third-Party Cabinet Rail Kits
X-02659-00 113-00232 Kit,4-Post,Square or Round-Hole, 24"-32" Rail
X5515A-R6 [1] 111-00232 Kit,2-Post (Round) or 4-Post (Square), 24"-32" Rail
X5525A-R6 111-00583 Kit,2-Post,Round-Hole
X5526A-R6 111-00593 Kit,4-Post.Square-Hole, 24"-32" Rail
X5529A-R6 111-00310 Kit,4-Post,Swift,Square-Hole, 24"-32" Rail

Field Replacement Unit Parts - FAS2554HA

Marketing Part No.Manufacturing Part No.Description
Battery
X1847 271-01847 Lithium System Battery CR2032
X1847-R6 271-01847 Lithium System Battery CR2032,R6
X3117A-R6 111-00908 Battery,FAS22XX,FAS25XX,NVMEM
Bezel
X80100A-R6 111-01320 Bezel,FAS2554,R6
X80100A-R6-C 111-01320 Bezel,FAS2554,R6,-C
Boot Media
X1425A-R6 N/A MEM,USB Media,2GB,Blank
Data Cable
X-SFP-H10GB-CU1M-R6 112-00210 Cable,10GBase Copper SFP+ 1m
X-SFP-H10GB-CU1M-R6-C 112-00210 Cable,10GBase Copper SFP+ 1m,-C
X-SFP-H10GB-CU1M-R6-N-C 112-00210 Cable,10GBase Copper SFP+ 1m,-C
X-SFP-H10GB-CU3M-R6 112-00211 Cable,10GBase Copper SFP+ 3m
X-SFP-H10GB-CU3M-R6-C 112-00211 Cable,10GBase Copper SFP+ 3m,-C
X-SFP-H10GB-CU3M-R6-N-C 112-00211 Cable,10GBase Copper SFP+ 3m,-C
X-SFP-H10GB-CU5M-R6 112-00212 Cable,10GBase Copper SFP+ 5m
X-SFP-H10GB-CU5M-R6-C 112-00212 Cable,10GBase Copper SFP+ 5m,-C
X-SFP-H10GB-CU5M-R6-N-C 112-00212 Cable,10GBase Copper SFP+ 5m,-C
X1983-1-R6 112-00210 Cable,Twinax CU,SFP+,1M,X1962/X1963/X1967
X1983-3-R6 112-00211 Cable,Twinax CU,SFP+,3M,X1962/X1963/X1967
X1983-5-R6 112-00212 Cable,Twinax CU,SFP+,5M,X1962/X1963/X1967
X6536-R6 112-00090 Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op
X6536-R6-C 112-00090 Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op,-C
X6536-R6-N-C 112-00090 Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op,-C
X6537-R6 112-00091 Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op
X6537-R6-C 112-00091 Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op,-C
X6537-R6-N-C 112-00091 Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op,-C
X6546-R6 112-00074 Cable,Cntlr-Shelf/Switch,30m,LC/SC,Op
X6547-R6 112-00073 Cable,Cntlr-Shelf/Switch,5m,LC/SC,Op
X6553-R6 112-00188 Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op
X6553-R6-C 112-00188 Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op,-C
X6553-R6-N-C 112-00188 Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op,-C  
X6554-R6 112-00189 Cable,Cntlr-Shelf/Switch,15m,LC/LC,Op
X6554-R6-C 112-00189 Cable,OPT,50u,2GHz/KM,MM,LC/LC,15M,-C,R6
X6554-R6-N-C 112-00189 Cable,OPT,50u,2GHz/KM,MM,LC/LC,15M,-C,R6,-C
X6557-EN-R6-C 112-00176 Cbl,SAS Cntlr-Shelf/Shelf-Shelf/HA,0.5m,EN,-C
X6557-R6 112-00176 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,0.5m
X6557-R6-C 112-00176 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,0.5m,-C
X6558-EN-R6-C 112-00177 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,2m,-C
X6558-R6 112-00177 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,2m
X6558-R6-C 112-00177 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,2m,-C
X6559-EN-R6-C 112-00178 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,5m,-C
X6559-R6 112-00178 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,5m
X6559-R6-C 112-00178 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,5m,-C
X6560-R6 112-00194 Cable,Ethernet,0.5m RJ45 CAT6
X6560-R6-C 112-00194 Cable,Ethernet,0.5m RJ45 CAT6,-C
X6560-R6-N-C 112-00194 Cable,Ethernet,0.5m RJ45 CAT6
X6561-R6 112-00195 Cable,Ethernet,2m RJ45 CAT6
X6561-R6-C 112-00195 Cable,Ethernet,2m RJ45 CAT6,-C
X6561-R6-N-C 112-00195 Cable,Ethernet,2m RJ45 CAT6,-C
X6562-R6 112-00196 Cable,Ethernet,5m RJ45 CAT6
X6562-R6-C 112-00196 Cable,Ethernet,5m RJ45 CAT6,-C
X6562-R6-N-C 112-00196 Cable,Ethernet,5m RJ45 CAT6,-C
X6566B-05-N-C 112-00297 Cable,Direct Attach CU SFP+ 10G,0.5M,-C
X6566B-05-R6 112-00297 Cable,Direct Attach CU SFP+ 10G,0.5M
X6566B-05-R6-C 112-00297 Cable,Direct Attach CU SFP+ 10G,0.5M,-C
X6566B-2-N-C 112-00299 Cable,Direct Attach CU SFP+ 10G,2M,-C
X6566B-2-R6 112-00299 Cable,Direct Attach CU SFP+ 10G,2M
X6566B-2-R6-C 112-00299 Cable,Direct Attach CU SFP+ 10G,2M,-C
X6566B-3-N-C 112-00300 Cable,Direct Attach CU SFP+ 10G,3M,-C
X6566B-3-R6 112-00300 Cable,Direct Attach CU SFP+ 10G,3M
X6566B-3-R6-C 112-00300 Cable,Direct Attach CU SFP+ 10G,3M,-C
X6566B-5-N-C 112-00301 Cable,Direct Attach CU SFP+ 10G,5M,-C
X6566B-5-R6 112-00301 Cable,Direct Attach CU SFP+ 10G,5M
X6566B-5-R6-C 112-00301 Cable,Direct Attach CU SFP+ 10G,5M,-C
X6577-R6 112-00238 Cable,Ethernet,30m RJ45 CAT6
X6577-R6-C 112-00238 Cable,Ethernet,30m RJ45 CAT6,-C
X6577-R6-N-C 112-00238 Cable,Ethernet,30m RJ45 CAT6,-C
X6584-R6 112-00290 Cable,Ethernet,1m RJ45 CAT6
X6584-R6-C 112-00290 Cable,Ethernet,1m RJ45 CAT6,-C
X6584-R6-N-C 112-00290 Cable,Ethernet,1m RJ45 CAT6,-C
X6585-R6 112-00291 Cable,Ethernet,3m RJ45 CAT6
X6585-R6-C 112-00291 Cable,Ethernet,3m RJ45 CAT6,-C
X6585-R6-N-C 112-00291 Cable,Ethernet,3m RJ45 CAT6,-C
X6590-R6 112-00242 Cable,SAS Cntlr-Shelf/Shelf-Shelf,10m
X6591-R6 112-00243 Cable,SAS Cntlr-Shelf/Shelf-Shelf,20m
X6592-R6 112-00246 Cable,Ethernet,10m RJ45 CAT6
X6592-R6-N-C 112-00246 Cable,Ethernet,10m RJ45 CAT6,-C
X6593-R6 112-00247 Cable,Ethernet,20m RJ45 CAT6
X6593-R6-C 112-00247 Cable,Ethernet,20m RJ45 CAT6,-C
X6593-R6-N-C 112-00247 Cable,Ethernet,20m RJ45 CAT6,-C
X6594-R6 112-00256 Cable,SAS Cntlr-Shelf/Shelf-Shelf,HA,1m
X6594-R6-C 112-00256 Cable,SAS Cntlr-Shelf/Shelf-Shelf,HA,1m,-C
X6595-R6 112-00255 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,3m
X6595-R6-C 112-00255 Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,3m,-C
X66000A-R6 112-00265 Cable,Storage,SAS-OM4,6G,QSFP,1m
X66000A-R6-C 112-00265 Cable,Storage,SAS-OM4,6G,QSFP,1m,-C
X66001A-R6 112-00266 Cable,Storage,SAS-OM4,6G,QSFP,2m
X66001A-R6-C 112-00266 Cable,Storage,SAS-OM4,6G,QSFP,2m,-C
X66002A-R6 112-00267 Cable,Storage,SAS-OM4,6G,QSFP,3m
X66002A-R6-C 112-00267 Cable,Storage,SAS-OM4,6G,QSFP,3m,-C
X66003A-R6 112-00268 Cable,Storage,SAS-OM4,6G,QSFP,5m
X66003A-R6-C 112-00268 Cable,Storage,SAS-OM4,6G,QSFP,5m,-C
X66004A-R6 112-00269 Cable,Storage,SAS-OM4,6G,QSFP,7m
X66005A-R6 112-00270 Cable,Storage,SAS-OM4,6G,QSFP,15m
X66006A-R6 112-00271 Cable,Storage,SAS-OM4,6G,QSFP,30m
X66007A-R6 112-00280 Cable,Storage,SAS-OM4,6G,QSFP,50m
X66008A-R6 112-00260 Cable,LT 150m-PatchP,OM4,6G,QSFP,LC,5m
X66008A-R6-C 112-00260 Cable,LT 150m-PatchP,OM4,6G,QSFP,LC,5m,-C
X66009A-R6 112-00261 Cable,LT 150m-PatchP,OM4,6G,QSFP,LC,30m
X66009A-R6-C 112-00261 Cable,LT 150m-PatchP,OM4,6G,QSFP,LC,30m,-C
X66010A-R6 112-00263 Cable,<150m-PatchP,OM4,6G,QSFP,SC,5m
X66011A-R6 112-00264 Cable,<150m-PatchP,OM4,6G,QSFP,SC,30m
X66012A-R6 112-00278 Cable,<150m-PatchP,OM4,6G,QSFP-MTRJ,5m
X66013A-R6 112-00279 Cable,<150m-PatchP,OM4,6G,QSFP-MTRJ,30m
X66020A-R6 112-00429 Cable,Storage,MiniSAS HD,QSFP,12G,1m
X66020A-R6-C 112-00429 Cable,Storage,MiniSAS HD,QSFP,12G,1m,-C
X66021A-R6 112-00430 Cable,Storage,MiniSAS HD,QSFP,12G,2m
X66021A-R6-C 112-00430 Cable,Storage,MiniSAS HD,QSFP,12G,2m,-C
X66022A-R6 112-00431 Cable,Storage,MiniSAS HD,QSFP,12G,5m
X66022A-R6-C 112-00431 Cable,Storage,MiniSAS HD,QSFP,12G,5m,-C
X66120-3 112-00545 Cable,Direct Attach CU 40G QSFP/4x10G SFP,3m
X66120-3-C 112-00545 Cable,Dir. Attach CU 40G QSFP/4x10G SFP,3m,-C
X66120-3-N-C 112-00545 Cable,Dir Attach CU 40G QSFP/4x10G SFP,3m,-C
X66120-5 112-00546 Cable,Direct Attach CU 40G QSFP/4x10G SFP,5m
X66120-5-C 112-00546 Cable,Dir. Attach CU 40G QSFP/4x10G SFP,5m,-C
X66120-5-N-C 112-00546 Cable,Dir Attach CU 40G QSFP/4x10G SFP,5m,-C
X66205-30 112-00261 Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m
X66205-30-C 112-00261 Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m,-C
X66205-30-N-C 112-00261 Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m,-C
X66205-5 112-00260 Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m
X66205-5-C 112-00260 Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m,-C
X66205-5-N-C 112-00260 Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m,-C
X66250-15 112-00346 Cable,LC-LC,OM4,15m
X66250-15-C 112-00346 Cable,LC-LC,OM4,15m,-C
X66250-15-N-C 112-00346 Cable,LC-LC,OM4,15m,-C
X66250-2 112-00342 Cable,LC-LC,OM4,2m
X66250-2-C 112-00342 Cable,LC-LC,OM4,2m,-C
X66250-2-N-C 112-00342 Cable,LC-LC,OM4,2m,-C
X66250-30 112-00347 Cable,LC-LC,OM4,30m
X66250-30-C 112-00347 Cable,LC-LC,OM4,30m,-C
X66250-30-N-C 112-00347 Cable,LC-LC,OM4,30m,-C
X66250-5 112-00344 Cable,LC-LC,OM4,5m
X66250-5-C 112-00344 Cable,LC-LC,OM4,5m,-C
X66250-5-N-C 112-00344 Cable,LC-LC,OM4,5m,-C
Drive
X302A-R5 108-00268 Disk Drive,1.0TB 7.2k,DS424x,FAS2240-4
X306A-R5 108-00270 Disk Drive,2.0TB 7.2k,DS424x,2554/2240-4
X308A-R5 108-00277 Disk Drive,3.0TB 7.2K,DS424x,2554/2240-4
X315A-R6 [1] 108-00368 DSK DRV,4TB 7.2k,NSE,DS424x,2554/2220/2240-4
X316A-R6 108-00389 Disk Drive,6TB 7.2k,DS4246,FAS2554
X317A [1] 108-00399 DSK DRV,6TB,7.2K,12G,NSE,DS212C
X318A-R6 108-00455 DSK DRV,8TB,7.2K,12G,DS212C
X319A 108-00687 SSD,7.6TB,12G,DS224C
X322A [1] 108-00551 DSK DRV,10TB,7.2K,12G,NSE,DS212C
X336A-R6 108-00427 DSK DRV,4TB,7.2K,12G,DS212C
X339A 108-00426 DSK DRV,2TB,7.2K,12Gb,DS212C,FAS2620
X341A-R6 108-00430 DSK DRV,900GB,10K,12G,DS224C
X342A-R6 108-00432 DSK DRV,1.2TB,10K,12G,DS224C
X343A-R6 108-00433 DSK DRV,1.8TB,10K,12G,DS224C
X356A-R6 108-00468 SSD,3.8TB,DS2246,FAS2552
X357A 108-00572 SSD,3.8TB,12G,DS224C,W/MSW
X358A [1] 108-00575 SSD,3.8TB,12G,NSE,DS224C
X363A-R6 108-00467 SSD,3.8TB,FAS2520/2554
X365A-R6 [1] 108-00477 SSD,1.6TB,NSE,DS2246,FAS2552
X366A-R6 [1] 108-00470, 108-00478 SSD,1.6TB,NSE,DS4246,FAS2554
X371A 108-00546 SSD,960GB,12G,DS224C,W/MSW
X374A 108-00573 SSD,960GB,12G,DS212C,W/MSW
X380A 108-00549 DSK DRV,10TB,7.2K,12G,DS212C
X386A [1] 108-00806 SSD,960GB,12G,NSE,DS224C
X388A 108-00885 DSK DRV,16TB,7.2K,12G,DS212C
X416A-R5 [1] 108-00223 Disk Drive,600GB 10k,NSE,DS224x,FAS2240-2
X417A-R6 [1] 108-00246 DSK DRV,900GB,10K,NSE,DS2246,2552/2240-2
X421A-R5 108-00220 Disk Drive,450GB 10k,DS224x,FAS2240-2
X422A-R5 108-00221 Disk Drive,600GB 10k,DS224x,2552/2240-2
X423A-R5 108-00222 DSK DRV,900GB,10K,DS2246,2552/2240-2,R5
X425A-R6 108-00321 DSK DRV,1.2TB,10K,DS2246,2552/2240-2
X426A-R6 108-00424 DSK DRV,1.8TB,10K,DS2246,2552/2240-2
X427A [1] 108-00476 DSK DRV,1.8TB,10k,NSE,DS2246,FAS2552
X427B-R6 [1] 108-00438 DSK DRV,1.8TB,10K,12G,NSE,DS224C
X438A-R6 108-00369 SSD,400GB,DS224x,FAS2552/2240-2
X439A-R6 108-00372 SSD,1.6TB,DS224x,FAS2552/2240-2
X440A-R6 [1] 108-00374 SSD,800GB,NSE,DS224x,FAS2240-2,FAS2552
X440B-R6 [1] 108-00460 SSD,800GB,12G,NSE,DS224C
X446B-R6 108-00323 SSD,200GB,B,DS224x,FAS2240-2,FAS2552
X447A-R6 108-00260 SSD,800GB,DS224x,FAS2552/2240-2
X448A-R6 108-00253 SSD,200GB,DS4246,FAS2554/2240-4/2220
X449A-R6 108-00319 SSD,800GB,DS4246,FAS2554/2240-4/2220
X477A-R6 108-00315 DSK DRV,4TB 7.2k,DS4246,2554/2220/2240-4
X488A-R5 108-00298 Disk Drive,900GB 10K,2520/2220
X489A-R6 108-00322 Disk Drive,1.2TB 10K,2520/2220
X490A-R6 108-00425 Disk Drive,1.8TB 10K,FAS2520
X575A-R6 108-00370 SSD,400GB,DS424x,FAS2554/2240-4/2220
X576A-R6 108-00373 SSD,1.6TB,DS424x,FAS2554/2240-4/2220
X577A-R6 [1] 108-00375 SSD,800GB,NSE,DS4246,FAS2554
X670A 108-00530 SSD,15.3TB,12G,DS224C
Memory Module
X3220A-R6 107-00165 DIMM,2GB,DDR3-800,LOW IDD6 for FAS25XX
X3221A-R6 107-00124 DIMM,16GB,DDR3-800 for FAS25XX
MotherBoard
X3400A-R6 111-01317 PCM,No Memory,FAS2554
Power Cord
X1558A-R6 N/A Jumper Crd,In-Cab,48-IN,C13-C14
X1558A-R6-C N/A Jumper Crd,In-Cab,48-IN,C13-C14-C
X800-42U-35 N/A Jumper Crd,In-Cab,C13-C14,35-inch
X800-42U-35-C N/A Jumper Crd,In-Cab,C13-C14,35-inch,-C
X800-42U-35-K-N N/A Jumper Crd,In-Cab,C13-C14,35-inch
X800-42U-35-N N/A Power Cable,In-Cabinet,C13-C14,35-inch
X800-42U-43 N/A Jumper Crd,In-Cab,C13-C14,43-inch
X800-42U-43-C N/A Jumper Crd,In-Cab,C13-C14,43-inch,-C
X800-42U-43-K-N N/A Jumper Crd,In-Cab,C13-C14,43-inch
X800-42U-43-N N/A Power Cable,In-Cabinet,C13-C14,43-inch
X800-42U-64 N/A Jumper Crd,In-Cab,C13-C14,64-inch
X800-42U-64-C N/A Jumper Crd,In-Cab,C13-C14,64-inch,-C
X800-42U-64-K-N N/A Jumper Crd,In-Cab,C13-C14,64-inch
X800-42U-64-N N/A Power Cable,In-Cabinet,C13-C14,64-inch
X800-42U-R6 N/A Jumper Crd,In-Cab,C13-C14
X800-42U-R6-C N/A Jumper Crd,In-Cab,C13-C14,-C
X800B-R6 N/A Power Cable,Continental Europe,R6
X800B-R6-C N/A Power Cable,Continental Europe,-C,R6
X800C-R6 N/A Power Cable,UK and Ireland,R6
X800C-R6-C N/A Power Cable,UK and Ireland,-C,R6
X800D-R6 N/A Power Cable,Japan,R6
X800D-R6-C N/A Power Cable,Japan,-C,R6
X800E-R6 N/A Power Cable,North America,R6
X800E-R6-C N/A Power Cable,North America,-C,R6
X800F-R6 N/A Power Cable,Australia/New Zealand,R6
X800F-R6-C N/A Power Cable,Australia/New Zealand,-C,R6
X800G-R6 N/A Power Cable,Switzerland,R6
X800G-R6-C N/A Power Cable,Switzerland,-C,R6
X800I-R6 N/A Power Cable,China,R6
X800I-R6-C N/A Power Cable,China,-C,R6
X800J-R6 N/A Power Cable,Denmark,R6
X800J-R6-C N/A Power Cable,Denmark,-C,R6
X800K-R6 N/A Power Cable,India,South Africa,R6
X800K-R6-C N/A Power Cable,India,South Africa,-C,R6
X800L-R6 N/A Power Cable,Israel,R6
X800L-R6-C N/A Power Cable,Israel,-C,R6
X800M-R6 N/A Power Cable,Italy,R6
X800M-R6-C N/A Power Cable,Italy,-C,R6
X800P-R6 N/A Power Cable,North America,250V,R6
X800P-R6-C N/A Power Cable,North America,250V,-C,R6
X800T-R6 N/A Power Cable,Taiwan,BSMI,R6
X800T-R6-C N/A Power Cable,Taiwan,BSMI,-C,R6
X800VB-R6 N/A Power Cable,Brazil,IEC-60906-1-Plug
X800W-R6 N/A Power Cable,Taiwan,250V,BSMI,R6
X800W-R6-C N/A Power Cable,Taiwan,250V,BSMI,-C
X800Y-R6 N/A Power Cable,Japan,250V/15A
X800Y-R6-C N/A Power Cable,Japan,250V/15A,-C
Power Supply Unit
X518A-R6 114-00070 PSU W/FANS,580W,AC,DS424x,R6
X522A-R6 114-00026 PSU W/FANS,Estar,580W,AC,DS424x
Transceiver
X65400A-R6 332-00335 QSFP,MPO,Optical Transceiver,6G,LT 150m,OM4
X6567-R6 332-00378 SFP Optical 1GB Shortwave Multimode
X6567-R6-C 332-00378 SFP Optical 1GB Shortwave Multimode,-C
X6567-R6-N-C 332-00378 SFP Optical 1GB Shortwave Multimode,-C
X6568-R6 332-00374 SFP Copper 1GB RJ-45
X6568-R6-C 332-00374 SFP Copper 1GB RJ-45,-C
X6568-R6-N-C 332-00374 SFP Copper 1GB RJ-45,-C
X6588-R6 332-00278R6 SFP+Optical 8Gb Shortwave
X6588-R6-C 332-00278R6 SFP+Optical 8Gb Shortwave,-C
X6588-R6-N-C 332-00278R6 SFP+Optical 8Gb Shortwave,-C
X6589-N-C 332-00279R6 SFP+Optical 10Gb Shortwave,-C
X6589-R6 332-00279R6 SFP+Optical 10Gb Shortwave
X6589-R6-C 332-00279R6 SFP+ Optical 10Gb Shortwave,-C
X6596-R6 332-00331 SFP+ FC Optical 16Gb
X6596-R6-C 332-00331 SFP+ FC Optical 16Gb,-C
X6596-R6-N-C 332-00331 SFP+ FC Optical 16Gb,-C
Footnote:
[1]Mixing NSE drives or shelves with any other type of encrypting or non-encrypting drives or shelves across a stand-alone platform or high-availability (HA) pair is not supported.

Supported Firmware Matrix - FAS2554HA

Major OS Version OS Version Firmeware
BIOS
ONTAP 9.8 9.8P13, 9.8P11-P12, 9.8P10, 9.8P9, 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4, 9.8P3, 9.8P2, 9.8P1, 9.8, 9.8RC1 8.3*
ONTAP 9.7 9.7P19, 9.7P17-P18, 9.7P16, 9.7P15, 9.7P14, 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 8.3*
ONTAP 9.6 9.6P18, 9.6P17, 9.6P16, 9.6P15, 9.6P13-P14, 9.6P12, 9.6P10-P11, 9.6P9, 9.6P7-P8, 9.6P5-P6, 9.6P4, 9.6P3, 9.6P2, 9.6, 9.6P1, 9.6RC2, 9.6RC1 8.3*
ONTAP 9.5 9.5P19, 9.5P18, 9.5P17, 9.5P16, 9.5P15, 9.5P14, 9.5P13, 9.5P12, 9.5P10-P11, 9.5P9, 9.5P8, 9.5P7, 9.5P6, 9.5P5, 9.5P4, 9.5P2-P3, 9.5P1, 9.5, 9.5RC1 8.3*
ONTAP 9.4 9.4P8, 9.4P7, 9.4P6, 9.4P5, 9.4P4, 9.4P3, 9.4P2, 9.4P1, 9.4, 9.4RC1 8.3*
ONTAP 9.3 9.3P21, 9.3P20, 9.3P18-P19, 9.3P16-P17, 9.3P15, 9.3P11-P14, 9.3P10, 9.3P7-P9, 9.3P1-P6, 9.3, 9.3RC1 8.3*
Clustered Data ONTAP 8.3 8.3.2, 8.3.2RC2, 8.3.2RC1, 8.3.1, 8.3.1RC1, 8.3, 8.3RC2, 8.3RC1 8.3*
ONTAP 9.2 9.2P2-P4, 9.2P1, 9.2, 9.2RC1 8.3*
Clustered Data ONTAP 8.2 8.2.4, 8.2.3, 8.2.2 8.3 (7-Mode)*, 8.3*, 8.2, 8.1*
Clustered Data ONTAP 8.2 8.2.2RC2, 8.2.2RC1 8.3 (7-Mode), 8.3, 8.2, 8.1*
7-Mode 8.2 8.2.5P5 8.3 (7-Mode)*
7-Mode 8.2 8.2.5 8.3 (7-Mode)*, 8.2, 8.1*
7-Mode 8.2 8.2.4, 8.2.3, 8.2.2 8.3 (7-Mode)*, 8.3*, 8.2, 8.1*
7-Mode 8.2 8.2.2RC2, 8.2.2RC1 8.3 (7-Mode), 8.3, 8.2, 8.1*
ONTAP 9.1 9.1P17-P20, 9.1P13-P16, 9.1P10-P12, 9.1P9, 9.1P8, 9.1P3-P7, 9.1P1-P2, 9.1, 9.1RC2, 9.1RC1 8.3*
ONTAP 9.0 9.0P1-P4, 9.0, 9.0RC2, 9.0RC1 8.3*
Footnote:
[1]* Indicates that firmware is bundled with Storage OS Version

Product Certificates - FAS2554HA

Certificate Name Geo / Region / Country Associated Products
Battery Pack safety reports
Lithium Battery Safety Doc-Section II/Section IB Shipments,Inventus Power Product Model#271-00029 Global Platforms : FAS2220, FAS2240-2, FAS2240-4, FAS2520, FAS2552, FAS2554
EMI and Safety certificates
Lithium Battery Safety Doc-Section II/Section IB Shipments,Inventus Power Product Model#271-00029 Global Platforms : FAS2220, FAS2240-2, FAS2240-4, FAS2520, FAS2552, FAS2554
Declaraion of Similarity NAJ-0801 Global Platforms : FAS2240-4, FAS2554
NAJ-0801 G-K-U-SoR Gabon,Kenya,SaudiArabia,Uganda Platforms : FAS2240-4, FAS2554
NAJ-0801 (Jabil Mexico) BIS BIS - India Platforms : FAS2240-4, FAS2554
NAJ-0801 (Jabil Singapore) BIS BIS - India Platforms : FAS2240-4, FAS2554
NAJ-0801 ACMA ACMA - Australia, New Zealand Platforms : FAS2240-4, FAS2554
NAJ-0801 BSMI BSMI - Taiwan Platforms : FAS2240-4, FAS2554
NAJ-0801 CB CB - International Platforms : FAS2240-4, FAS2554
NAJ-0801 CE CE - European Union DoC Platforms : FAS2240-4, FAS2554
NAJ-0801 CSA CSA - United States, Canada Platforms : FAS2240-4, FAS2554
NAJ-0801 EAC EAC - Armenia, Belarus, Kazakhstan, Kyrgyzstan, Russia Platforms : FAS2240-4, FAS2554
NAJ-0801 IRAM IRAM - Argentina Platforms : FAS2240-4, FAS2554
NAJ-0801 KC KC - South Korea Platforms : FAS2240-4, FAS2554
NAJ-0801 Morocco Morocco Platforms : FAS2240-4, FAS2554
NAJ-0801 NOM NOM - Mexico Platforms : FAS2240-4, FAS2554
NAJ-0801 NRCS SABS NRCS - South Africa (Safety) Platforms : FAS2240-4, FAS2554
NAJ-0801 SONCAP SONCAP - Nigeria Platforms : FAS2240-4, FAS2554
NAJ-0801 TBS TBS - Tanzania Platforms : FAS2240-4, FAS2554
NAJ-0801 UKRSepro UKRSepro - Ukraine Platforms : FAS2240-4, FAS2554
NAJ-0801 VCCI VCCI - Japan Platforms : FAS2240-4, FAS2554
Voluntary Product Accessibility Template
NAJ-0801 VCCI VCCI - Japan Platforms : FAS2240-4, FAS2554

Size, Weight, Acoustic, Power FAS2554HA

Associated Part No. Configuration Rack Units Weight Sound Power Sound Pressure Line Voltage Actual (Min to Max) Amps Typical Amps Worst Watts Typical Watts Worst BTU / Hr Typical BTU / Hr Worst
Embedded Drive Config (Half)
FAS2554-307-R6-C FAS2554 2PCM 12x2TB 4 86.6 lb (39.3 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 3.79 5.42 370 532 1262 1814
FAS2554-307-R6-C FAS2554 2PCM 12x2TB 4 86.6 lb (39.3 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 1.86 2.62 360 511 1228 1743
FAS2554-308-R6-C FAS2554 2PCM 12x3TB 4 86.6 lb (39.3 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 4.17 5.64 407 547 1388 1865
FAS2554-308-R6-C FAS2554 2PCM 12x3TB 4 86.6 lb (39.3 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.04 2.74 394 534 1344 1821
FAS2554-309-R6-C FAS2554 1PCM 12x4TB 4 81.9 lb (37.2 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 2.68 3.58 262 350 895 1195
FAS2554-309-R6-C FAS2554 1PCM 12x4TB 4 81.9 lb (37.2 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 1.32 1.75 257 343 878 1171
FAS2554-309-R6-C FAS2554 2PCM 12x4TB 4 112.9 lb (51.2 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 4.05 5.85 395 576 1347 1964
FAS2554-309-R6-C FAS2554 2PCM 12x4TB 4 112.9 lb (51.2 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.04 2.89 400 563 1364 1920
FAS2554-310-R6-C FAS2554 1PCM 12x4TB 4 81.9 lb (37.2 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 2.68 3.58 262 350 895 1195
FAS2554-310-R6-C FAS2554 1PCM 12x4TB 4 81.9 lb (37.2 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 1.32 1.75 257 343 878 1171
FAS2554-310-R6-C FAS2554 2PCM 12x4TB 4 112.9 lb (51.2 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 4.05 5.85 395 576 1347 1964
FAS2554-310-R6-C FAS2554 2PCM 12x4TB 4 112.9 lb (51.2 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.04 2.89 400 563 1364 1920
FAS2554-314-R6-C FAS2554 1PCM 12x6TB 4 81.9 lb (37.2 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 2.42 3.33 237 326 809 1113
FAS2554-314-R6-C FAS2554 1PCM 12x6TB 4 81.9 lb (37.2 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 1.19 1.64 233 320 796 1093
FAS2554-314-R6-C FAS2554 2PCM 12x6TB 4 65.9 lb (29.9 kg) 100 (100 to 120) 3.33 4.24 326 415 1113 1417
FAS2554-314-R6-C FAS2554 2PCM 12x6TB 4 65.9 lb (29.9 kg) 200 (200 to 240) 1.64 2.08 320 407 1093 1390
FAS2554-321-C FAS2554 1PCM 12x6TB NSE 4 81.9 lb (37.2 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 2.42 3.33 237 326 809 1113
FAS2554-321-C FAS2554 1PCM 12x6TB NSE 4 81.9 lb (37.2 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 1.19 1.64 233 320 796 1093
FAS2554-325-C FAS2554 1PCM 12x8TB 4 79.8 lb (36.2 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 3.09 3.88 302 380 1031 1297
FAS2554-325-C FAS2554 1PCM 12x8TB 4 79.8 lb (36.2 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 1.52 1.91 296 373 1011 1274
FAS2554-325-C FAS2554 2PCM 12x8TB 4 84.2 lb (38.2 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 3.93 4.73 385 463 1314 1581
FAS2554-325-C FAS2554 2PCM 12x8TB 4 84.2 lb (38.2 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 1.93 2.32 378 454 1291 1550
Embedded Drive Config (Full)
FAS2554-303-R6-C FAS2554 1PCM 24x2TB 4 101.2 lb (45.9 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 4.29 5.92 418 580 1425 1978
FAS2554-303-R6-C FAS2554 1PCM 24x2TB 4 101.2 lb (45.9 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.11 2.87 408 559 1391 1906
FAS2554-303-R6-C FAS2554 2 PCM 24x2TB 4 107.1 lb (48.6 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 4.72 6.28 478 640 1630 2182
FAS2554-303-R6-C FAS2554 2 PCM 24x2TB 4 107.1 lb (48.6 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.46 3.13 468 619 1596 2111
FAS2554-304-R6-C FAS2554 1PCM 24x3TB 4 101.2 lb (45.9 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 4.48 5.89 437 577 1490 1968
FAS2554-304-R6-C FAS2554 1PCM 24x3TB 4 101.2 lb (45.9 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.19 2.89 424 564 1446 1923
FAS2554-304-R6-C FAS2554 2 PCM 24x3TB 4 107.1 lb (48.6 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 5.13 6.48 497 637 1695 2172
FAS2554-304-R6-C FAS2554 2 PCM 24x3TB 4 107.1 lb (48.6 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.48 3.2 484 624 1650 2128
FAS2554-305-R6-C FAS2554 1PCM 24x4TB NL-SAS 4 101.2 lb (45.9 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 4.32 6.12 437 618 1490 2107
FAS2554-305-R6-C FAS2554 1PCM 24x4TB NL-SAS 4 101.2 lb (45.9 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.3 3.05 442 605 1507 2063
FAS2554-305-R6-C FAS2554 2PCM 24x4TB NL-SAS 4 107.1 lb (48.6 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 4.91 6.71 497 678 1695 2312
FAS2554-305-R6-C FAS2554 2PCM 24x4TB NL-SAS 4 107.1 lb (48.6 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.61 3.35 502 665 1712 2268
FAS2554-306-R6-C FAS2554 1PCM 24x4TB NL-SAS 4 101.2 lb (45.9 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 4.32 6.12 437 618 1490 2107
FAS2554-306-R6-C FAS2554 1PCM 24x4TB NL-SAS 4 101.2 lb (45.9 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.3 3.05 442 605 1507 2063
FAS2554-306-R6-C FAS2554 2PCM 24x4TB NL-SAS 4 107.1 lb (48.6 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 4.91 6.71 497 678 1695 2312
FAS2554-306-R6-C FAS2554 2PCM 24x4TB NL-SAS 4 107.1 lb (48.6 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.61 3.35 502 665 1712 2268
FAS2554-313-R6-C FAS2554 1PCM 24x6TB 4 106.7 lb (48.4 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 5.05 5.82 500 577 1705 1968
FAS2554-313-R6-C FAS2554 1PCM 24x6TB 4 106.7 lb (48.4 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.51 2.96 477 562 1627 1916
FAS2554-313-R6-C FAS2554 2PCM 24x6TB 4 111.3 lb (50.5 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 5.65 6.54 562 650 1916 2217
FAS2554-313-R6-C FAS2554 2PCM 24x6TB 4 111.3 lb (50.5 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.83 3.27 538 628 1835 2141
FAS2554-322-C FAS2554 1PCM 24x6TB NSE 4 106.7 lb (48.4 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 5.05 5.82 500 577 1705 1968
FAS2554-322-C FAS2554 1PCM 24x6TB NSE 4 106.7 lb (48.4 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.51 2.96 477 562 1627 1916
FAS2554-322-C FAS2554 2 PCM 24x6TB NSE 4 113.1 lb (51.3 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 5.72 6.52 560 638 1912 2178
FAS2554-322-C FAS2554 2 PCM 24x6TB NSE 4 113.1 lb (51.3 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.81 3.2 549 626 1874 2137
FAS2554-326-C FAS2554 1PCM 24x8TB 4 106.7 lb (48.4 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 4.92 5.72 482 560 1646 1912
FAS2554-326-C FAS2554 1PCM 24x8TB 4 106.7 lb (48.4 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.42 2.81 473 549 1615 1874
FAS2554-326-C FAS2554 2PCM 24x8TB 4 111.1 lb (50.4 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 5.77 6.57 565 643 1929 2195
FAS2554-326-C FAS2554 2PCM 24x8TB 4 111.1 lb (50.4 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.83 3.22 554 631 1891 2154
FAS2554-333-C FAS2554 1PCM 24x10TB SAS FIPS 4 100.3 lb (45.5 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 4.21 5 412 490 1407 1673
FAS2554-333-C FAS2554 1PCM 24x10TB SAS FIPS 4 100.3 lb (45.5 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.07 2.46 404 481 1379 1642
FAS2554-333-C FAS2554 2 PCM 24x10TB SAS FIPS 4 104.7 lb (47.5 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 5.06 5.85 495 573 1690 1956
FAS2554-333-C FAS2554 2 PCM 24x10TB SAS FIPS 4 104.7 lb (47.5 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.48 2.87 486 562 1659 1919
Embedded Drive Config (Mixed)
FAS2554-301-R6-C FAS2554 1PCM 20x2TB, 4x400GB 4 96.3 lb (43.7 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 3.24 4.14 317 405 1082 1383
FAS2554-301-R6-C FAS2554 1PCM 20x2TB, 4x400GB 4 96.3 lb (43.7 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 1.59 2.03 311 397 1062 1355
FAS2554-301-R6-C FAS2554 2 PCM 20x2TB, 4x400GB 4 100.8 lb (45.7 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 5.14 5.93 503 581 1717 1983
FAS2554-301-R6-C FAS2554 2 PCM 20x2TB, 4x400GB 4 100.8 lb (45.7 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.52 2.91 493 570 1683 1946
FAS2554-302-R6-C FAS2554 1PCM 20x4TB, 4x400GB 4 96.3 lb (43.7 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 3.95 4.86 387 476 1321 1625
FAS2554-302-R6-C FAS2554 1PCM 20x4TB, 4x400GB 4 96.3 lb (43.7 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 1.94 2.39 380 467 1297 1594
FAS2554-302-R6-C FAS2554 2PCM 20x4TB, 4x400GB 4 104.3 lb (47.3 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 5.29 6.09 518 596 1768 2035
FAS2554-302-R6-C FAS2554 2PCM 20x4TB, 4x400GB 4 104.3 lb (47.3 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.6 2.99 508 585 1734 1997
FAS2554-311-R6-C FAS2554 1PCM 20x2TB, 4x200GB 4 96.3 lb (43.7 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 3.28 4.19 321 410 1096 1400
FAS2554-311-R6-C FAS2554 1PCM 20x2TB, 4x200GB 4 96.3 lb (43.7 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 1.61 2.06 315 402 1076 1372
FAS2554-311-R6-C FAS2554 2PCM 20x2TB, 4x200GB 4 107.8 lb (48.9 kg) 100 (100 to 120) 4.19 5.1 410 499 1400 1704
FAS2554-311-R6-C FAS2554 2PCM 20x2TB, 4x200GB 4 107.8 lb (48.9 kg) 200 (200 to 240) 2.06 2.5 402 490 1372 1673
FAS2554-312-R6-C FAS2554 1PCM 20x4TB, 4x200GB 4 96.3 lb (43.7 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 3.84 4.74 376 464 1284 1584
FAS2554-312-R6-C FAS2554 1PCM 20x4TB, 4x200GB 4 96.3 lb (43.7 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 1.89 2.33 369 455 1260 1553
FAS2554-312-R6-C FAS2554 2PCM 20x4TB, 4x200GB 4 110.0 lb (49.9 kg) 100 (100 to 120) 4.74 5.65 464 553 1584 1888
FAS2554-312-R6-C FAS2554 2PCM 20x4TB, 4x200GB 4 110.0 lb (49.9 kg) 200 (200 to 240) 2.33 2.77 455 542 1553 1850
FAS2554-315-R6-C FAS2554 1PCM 20x6TB, 4x200GB 4 104.3 lb (47.3 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 4.78 5.46 474 541 1616 1845
FAS2554-315-R6-C FAS2554 1PCM 20x6TB, 4x200GB 4 104.3 lb (47.3 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.43 2.8 462 532 1575 1814
FAS2554-315-R6-C FAS2554 2PCM 20x6TB, 4x200GB 4 108.9 lb (49.4 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 5.38 6.18 535 615 1824 2097
FAS2554-315-R6-C FAS2554 2PCM 20x6TB, 4x200GB 4 108.9 lb (49.4 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.75 3.11 513 599 1749 2043
FAS2554-316-R6-C FAS2554 1PCM 20x6TB, 4x400GB 4 104.3 lb (47.3 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 4.78 5.46 474 541 1616 1845
FAS2554-316-R6-C FAS2554 1PCM 20x6TB, 4x400GB 4 104.3 lb (47.3 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.43 2.8 462 532 1575 1814
FAS2554-316-R6-C FAS2554 2PCM 20x6TB, 4x400GB 4 108.9 lb (49.4 kg) 6.1 Bels 49.6 dBA 100 (100 to 120) 5.38 6.18 535 615 1824 2097
FAS2554-316-R6-C FAS2554 2PCM 20x6TB, 4x400GB 4 108.9 lb (49.4 kg) 6.1 Bels 49.6 dBA 200 (200 to 240) 2.75 3.11 513 599 1749 2043
FAS2554-317-R6-C FAS2554 1PCM 20x2TB SATA, 4x800GB 4 95.5 lb (43.3 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 4.29 5.09 420 498 1434 1700
FAS2554-317-R6-C FAS2554 1PCM 20x2TB SATA, 4x800GB 4 95.5 lb (43.3 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.11 2.5 412 489 1407 1669
FAS2554-317-R6-C FAS2554 2 PCM 20x2TB SATA, 4x800GB 4 100.8 lb (45.7 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 5.14 5.93 503 581 1717 1983
FAS2554-317-R6-C FAS2554 2 PCM 20x2TB SATA, 4x800GB 4 100.8 lb (45.7 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.52 2.91 493 570 1683 1946
FAS2554-318-R6-C FAS2554 1PCM 20x4TB, 4x800GB 4 99.0 lb (44.9 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 4.44 5.24 435 513 1485 1751
FAS2554-318-R6-C FAS2554 1PCM 20x4TB, 4x800GB 4 99.0 lb (44.9 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.18 2.57 427 503 1458 1717
FAS2554-318-R6-C FAS2554 2PCM 20x4TB, 4x800GB 4 104.3 lb (47.3 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 5.29 6.09 518 596 1768 2035
FAS2554-318-R6-C FAS2554 2PCM 20x4TB, 4x800GB 4 104.3 lb (47.3 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.6 2.99 508 585 1734 1997
FAS2554-319-R6-C FAS2554 1PCM 18x4TB, 6x800GB 4 101.2 lb (45.9 kg) 100 (100 to 120) 4.4 4.98 429 492 1463 1678
FAS2554-319-R6-C FAS2554 1PCM 18x4TB, 6x800GB 4 101.2 lb (45.9 kg) 200 (200 to 240) 2.38 2.59 450 510 1535 1739
FAS2554-319-R6-C FAS2554 2PCM 18x4TB, 6x800GB 4 107.1 lb (48.6 kg) 100 (100 to 120) 5 5.7 493 535 1687 1830
FAS2554-319-R6-C FAS2554 2PCM 18x4TB, 6x800GB 4 107.1 lb (48.6 kg) 200 (200 to 240) 2.7 2.9 480 549 1642 1878
FAS2554-320-R6-C FAS2554 1PCM 20x6TB, 4x800GB 4 103.4 lb (46.9 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 4.46 5.27 437 516 1492 1762
FAS2554-320-R6-C FAS2554 1PCM 20x6TB, 4x800GB 4 103.4 lb (46.9 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.19 2.59 429 506 1465 1727
FAS2554-320-R6-C FAS2554 2 PCM 20x6TB, 4x800GB 4 108.7 lb (49.3 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 5.31 6.11 520 598 1775 2041
FAS2554-320-R6-C FAS2554 2 PCM 20x6TB, 4x800GB 4 108.7 lb (49.3 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.61 3 510 587 1741 2004
FAS2554-323-C FAS2554 1PCM 20x6TB, 4x800GB 4 103.4 lb (46.9 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 4.46 5.27 437 516 1492 1762
FAS2554-323-C FAS2554 1PCM 20x6TB, 4x800GB 4 103.4 lb (46.9 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.19 2.59 429 506 1465 1727
FAS2554-323-C FAS2554 2 PCM 20x6TB, 4x800GB 4 108.7 lb (49.3 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 5.31 6.11 520 598 1775 2041
FAS2554-323-C FAS2554 2 PCM 20x6TB, 4x800GB 4 108.7 lb (49.3 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.61 3 510 587 1741 2004
FAS2554-324-C FAS2554 1PCM 18x6TB, 6x800GB 4 10.8 lb (4.9 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 4.27 5.07 418 496 1427 1693
FAS2554-324-C FAS2554 1PCM 18x6TB, 6x800GB 4 10.8 lb (4.9 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.1 2.49 410 487 1400 1663
FAS2554-324-C FAS2554 2 PCM 18x6TB, 6x800GB 4 107.1 lb (48.6 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 5.12 5.91 501 579 1710 1977
FAS2554-324-C FAS2554 2 PCM 18x6TB, 6x800GB 4 107.1 lb (48.6 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.51 2.9 491 568 1676 1939
FAS2554-324-C FAS2554 2PCM 18x6TB, 6x800GB 4 99.7 lb (45.2 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 5.21 6.2 516 600 1760 2046
FAS2554-324-C FAS2554 2PCM 18x6TB, 6x800GB 4 99.7 lb (45.2 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.9 3.1 515 591 1757 2016
FAS2554-327-C FAS2554 1PCM 20x8TB, 4x400GB 4 102.3 lb (46.4 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 4.52 5.31 442 520 1509 1775
FAS2554-327-C FAS2554 1PCM 20x8TB, 4x400GB 4 102.3 lb (46.4 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.22 2.61 434 510 1482 1741
FAS2554-327-C FAS2554 2 PCM 20x8TB, 4x400GB 4 106.7 lb (48.4 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 5.36 6.16 525 603 1792 2058
FAS2554-327-C FAS2554 2 PCM 20x8TB, 4x400GB 4 106.7 lb (48.4 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.63 3.02 515 591 1758 2018
FAS2554-328-C FAS2554 1PCM 20x8TB, 4x800GB 4 102.3 lb (46.4 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 4.52 5.31 442 520 1509 1775
FAS2554-328-C FAS2554 1PCM 20x8TB, 4x800GB 4 102.3 lb (46.4 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.22 2.61 434 510 1482 1741
FAS2554-328-C FAS2554 2 PCM 20x8TB, 4x800GB 4 108.2 lb (49.1 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 4.62 5.41 452 530 1543 1809
FAS2554-328-C FAS2554 2 PCM 20x8TB, 4x800GB 4 108.2 lb (49.1 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.27 2.66 443 520 1512 1775
FAS2554-328-C FAS2554 2PCM 20x8TB, 4x800GB 4 106.7 lb (48.4 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 5.36 6.16 525 603 1792 2058
FAS2554-328-C FAS2554 2PCM 20x8TB, 4x800GB 4 106.7 lb (48.4 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.63 3.02 515 591 1758 2018
FAS2554-329-C FAS2554 2 PCM 18x8TB, 6x800GB NSE 4 107.1 lb (48.6 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 5.12 5.91 501 579 1710 1977
FAS2554-329-C FAS2554 2 PCM 18x8TB, 6x800GB NSE 4 107.1 lb (48.6 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.51 2.9 491 568 1676 1939
FAS2554-330-C FAS2554 1PCM 20x6TB NSE, 4x1.6TB NSE 4 102.7 lb (46.6 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 4.44 5.24 435 513 1485 1751
FAS2554-330-C FAS2554 1PCM 20x6TB NSE, 4x1.6TB NSE 4 102.7 lb (46.6 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.18 2.57 427 503 1458 1717
FAS2554-330-C FAS2554 2 PCM 20x6TB NSE, 4x1.6TB NSE 4 107.1 lb (48.6 kg) 6.9 Bels 49.6 dBA 100 (100 to 120) 5.29 6.09 518 596 1768 2035
FAS2554-330-C FAS2554 2 PCM 20x6TB NSE, 4x1.6TB NSE 4 107.1 lb (48.6 kg) 6.9 Bels 49.6 dBA 200 (200 to 240) 2.6 2.99 508 585 1734 1997

 

Shipping Information

Express Computer Systems can ship to virtually any address in the world and provides you with the best shipping rates possible. Cost of shipping varies depending on what service you require, your destination and size of the shipment. Shipping costs will be calculated separately from your order and billed to you post purchase. In the notes section of your order please provide us with your preferred shipping method and we will get back to you.

Custom configured orders ship within 2 business days after all required products are in stock.

Please allow 3 business days for products that are not in stock to arrive to our facility in Irvine, California.

Domestic Shipments
  • Standard Ground
    • Shipping time: 2-7 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-10 business days
    • Excludes weekends, holidays or weather delays.
  • 3 Business Days
    • Shipping time: 3 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 3-6 business days
    • Excludes weekends, holidays or weather delays.
  • 2 Business Days
    • Shipping time: 2 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-5 business days
    • Excludes weekends, holidays or weather delays.
  • Overnight / Next Business Day
    • Shipping time: 1 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 1-4 business days
    • Excludes weekends, holidays or weather delays.
International Shipments
  • International Economy
    • Shipping time: 4-6 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 5-9 business days
    • Excludes weekends, holidays or weather delays.
  • International Priority
    • Shipping time: 1-3 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-6 business days
    • Excludes weekends, holidays or weather delays.

For more information on shipping view our Shipping Information page or send us a message

ECS Warranty Information

Express Computer Systems (ECS) provides a 1 year parts warranty against defects in material or workmanship that will affect the products functionality. All refurbished items are tested prior to shipping to guarantee up-time upon arrival. If you are having issues with an item we provided please Contact Us and we will do our best to assist you.

What does our ECS warranty cover?
We offer 1 year warranty as standard and additional years can be added to fit your needs. Please reach out to a sales associate via the Contact Us page or live chat for more information on extended coverage options. During the coverage period if your product fails we will offer a Next Business Day replacement. If we are unable to replace the product we will refund its original selling price. Shipping costs and tax are not refundable. Express Computer Systems retains the right to decide whether the goods will be replaced or refunded.

What is not covered by our warranty?
Our warranty does not cover any problem caused by the following conditions:

  1. accidents; misuse; carelessness; electrostatic discharge; shock; temperature or humidity beyond the specifications of the product; improper installation; operation; modification;
  2. any improper use that contravenes the instructions in the user manual;
  3. problems caused by other equipment. Our warranty is void if the product is returned with damaged, removed, counterfeit labels, or any modifications (including any component or external cover removal). Our warranties do not cover data loss or damages to any other equipment. In addition, our warranties do not cover incidental damages, consequential damages, or costs related to data recovery, removal, and installation.

Important notes:

  • Please ask for additional warranty/coverage that you may require in addition to the standard 1 ECS warranty prior to final purchase. Requesting additional warranty after your purchase can be denied.
  • FREE technical support is provided on purchased items via phone, email, or live chat.

About Express Computer Systems

Express Computer Systems is committed to transforming our customers’ IT infrastructure with high quality products at affordable costs. Our sales reps and customer support engineers understand our customers rely heavily on advanced technology to run their business but need to do so without breaking the bank.

We specialize in building custom server configurations, custom storage solutions, networking solutions, and components from top manufacturers including HPE, Dell, Cisco, NetApp, Dell EMC, HPE Nimble and many others.

Subscribe