Storage Limits
Max # of Drives (Total) | Max # of Internal Drives | Max # of MSATA Drives | Max # of NL-SAS Drives | Max # of SAS Drives | Max # of SATA Drives | Max # of SSD Drives | Max # of DS212C Shelves | Max # of DS2246 Shelves | Max # of DS224C Shelves | Max # of DS4243 Shelves | Max # of DS4246 Shelves | Max # of DS4486 Shelves | Max # of DS460C Shelves |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
144 | 24 | - | - | - | - | 144 | - | 5 external | 1 internal + 5 external | - | - | - | - |
Capacity Limits
Marketing Max Raw Capacity - Node | HA Pair | Cluster | Effective Capacity - Node | HA Pair | Cluster |
---|---|---|---|---|---|
4406400 | 4406400 | - | 19557806.4 | 19557806.4 | - |
Core Cluster Limits
Max SVM's - NAS | Max LIF's - NAS | Max Connections - NAS | Max Flexible Volumes - NAS | Max Flexible Volumes with DPO - NAS | Max Lock Manager Locked Objects | Max Intercluster LIFs - Node | Min Root Aggregate (MiB) - Node | Min Root Volume (GiB) - Node | Max IPsec Policies | Max Auditing-Enabled SVMs - Cluster |
---|---|---|---|---|---|---|---|---|---|---|
Node:- HA Pair:- Cluster:512 | Node:512 HA Pair:512 Cluster:3072 | Node:100000 HA Pair(Non-Scalable):100000 | Aggregate (Single data Agg. per Node):- Aggregate (Multiple data Agg. per Node):- Node:1000 HA Pair:2000 Cluster:15000 | Node:1500 HA Pair:3000 Cluster:12000 | Node:1200000 HA Pair:1200000 Cluster:12288000 | 8 | 191488 | 150 | SVM:256 Cluster:1500 | 50 |
System Maximums and Limits
Max Nodes per Cluster (NAS / SAN) | Max FabricPool Size | Max FlexGroup Data Constituent Size | Max Infinite Volume Data Constituent Size | Min Root Volume Size | NetApp Volume Encryption |
---|---|---|---|---|---|
24 / 12 | 16800 TiB | 100 TiB | Not Supported | 150 GiB [1] | Supported |
Processor
Processor Model | Processor Architecture | Processor Speed | Processor Count (Per Node) | Processor Count (Per Config) | Processor Cores (Per CPU) | Processor Cores (Per Node) | Processor Cores (Per Config) |
---|---|---|---|---|---|---|---|
64-bit 12-core 1.50 Ghz | 64 bit | 1.50 Ghz | 1 | 2 | 12 | 12 | 24 |
Memory
NVRAM (Per Node) | NVRAM (Per Config) | NVME (Per Node) | NVME (Per Config) | NVMEM (Per Node) | NVMEM (Per Config) | RAM (Per Node) | RAM (Per Config) |
---|---|---|---|---|---|---|---|
- | - | - | - | 4 GB | 8 GB | 32 GB | 64 GB |
Onboard Ports
Ethernet Ports | Fibre Channel | Ports UTA2 Ports | Expansion Slots | SAS Ports |
---|---|---|---|---|
8 x RJ45 (10Gb) + 4 x SFP+ (10Gb) | - | - | - | 4 x MiniSAS HD (12Gb) |
Physical Characteristics
Rack Units | Chassis Height | Chassis Width with Mounting Flanges | Chassis Width without Mounting Flanges | Chassis Depth with Cable Mgmt | Chassis Depth without Cable Mgmt | Chassis Weight |
---|---|---|---|---|---|---|
2 | 3.35" (8.5 cm) | 18.9" (48 cm) | 17.6" (44.7 cm) | 24.13" (61.3 cm) | 19.02" (48.3 cm) | See Weights by configuration |
System Clearance Dimensions
Front Clearance (Cooling) | Front Clearance (Maintenance) | Rear Clearance (Cooling) | Rear Clearance (Maintenance) |
---|---|---|---|
6.03" (15.3 cm) | 24.03" (61 cm) | 6.03" (15.3 cm) | 13" (33 cm) |
Environmental Requirements
Operating | Storage | Transit | Acoustic Noise | Input Power Voltage |
---|---|---|---|---|
Tempature: 41 to 113 deg F - 5 to 45 deg C Humidity: 8 to 90 % Altitude: Up to 10000.0 ft - Up to 3048.0 m | Tempature: -40 to 158 deg F - -40 to 70 deg C Humidity: 10 to 95 % Altitude: Up to 40000.0 ft - Up to 12192.0 m | Tempature: -40 to 158 deg F - -40 to 70 deg C Humidity: 10 to 95 % Altitude: Up to 39989.8 ft - Up to 12192 m | Sound Power: 6.9 bels Sound Pressure: 51 dBA | 100 to 120 200 to 240 |
Storage OS Requirements
Full OS Matrix | Recommended Version | Minimum OS | Maximum OS |
---|---|---|---|
View Full OS Report Below | 9.11.1 | 9.11.1RC1 | 9.11.1 |
Storage and Firmware
Full Firmware Matrix | BIOS | BMC |
---|---|---|
Full Firmware Report Below | 11.15* | 11.8* |
Product Standards Compliance
Full Compliance and Certificates Report | Cert. EMC/EMI | Cert. Safety | Cert. Safety/EMC/EMI | Cert. Safety/EMC/EMI/RoHS | Standard Safety/EMC/EMI | Standard Safety |
---|---|---|---|---|---|---|
- Below | - | - | - | - | - | - |
NFS Cluster Limits
Max Export Policies - Cluster | Max Export Rules - Cluster | Max NFSv4 Access Control Entries | Max Client Objects | Max pNFS objects |
---|---|---|---|---|
24000 | 200000 | 1024 | Node:10000 HA Pair:10000 | Node:524288 HA Pair:524288 Cluster:1048576 |
WAFL Cluster Limits - All Maximums
Size 64-bit Aggregate (TiB) | Size 64-bit Volume (TiB) | File size 64-bit Volume (TiB) | Volume Snapshot Copies | Character length for Snapshot copy names | Hard links - File | inodes/files - Volume | Number of qtrees | Concurrent DataMotion for Volumes ops |
---|---|---|---|---|---|---|---|---|
800 | 100 | 16 | Volume:1023 Node:1023000 HA Pair:2046000 | 255 | 100000 | 2000000000 | Volume:4995 Node:100000 HA Pair:200000 Cluster:400000 | Node:16 HA Pair:16 |
Quality of Service Cluster Limits
Max Policy Groups - Cluster | Max QoS User Workloads - Cluster |
---|---|
12000 | 40000 |
SAN Cluster Limits - All Maximums
# of storage virtual machines (SVMs) - SAN | # of flexible volumes - SAN | # of Flexible Vol with DPO - | # of LUNs | LUN mappings | LUN size (TiB) - LUN | FC queue depth available | # of SAN Hosts (ITNs) | # of LIFS - iSCSI | # of LIFS - FCP | # of igroups | # of Initiators | # of Portsets | # of iSCSI sessions |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Node:125 HA Pair:250 Cluster:1000 | Single data Aggregate:- Multiple data Aggregates:- Node:1000 HA Pair:2000 Cluster:12000 | Node:1500 HA Pair:3000 Cluster:12000 | Valume:1024 Node:8192 HA Pair:16384 Cluster:65536 | Node:8192 HA Pair:16384 Cluster:65536 | 16 | 2048 | Port:512 Node:4096 HA Pair:8192 Cluster:32768 | Port:32 Portset:32 Node:512 HA Pair:1024 Cluster:4096 | Port:32 Portset:32 Node:512 HA Pair:1024 Cluster:4096 | Node:2048 HA Pair:4096 Cluster:16384 | igroup:256 Node:2048 HA Pair:4096 Cluster:16384 | Node:2048 HA Pair:4096 Cluster:16384 | Node:4096 HA Pair:8192 Cluster:32768 |
CIFS Cluster Limits - All Maximums
# of Connected Shares | # of Regular Shares | # of Open files | # of Local users - Cluster | # of Local groups - Cluster | # of Local group members - Cluster |
---|---|---|---|---|---|
Node:800000 HA Pair:800000 | Node:- HA Pair:- Cluster:60000 | Connection:65536 Node:600000 HA Pair:600000 | 5000 | 10000 | 30000 |
Data Protection Cluster Limits - All Maximums
NDMP Sessions | Data Protection Mirrors | Load Sharing Mirrors - NAS SVM | Concurrent Snap Mirror / SnapVault transfers - Node | DP Mirror fan-out - Volume | LS Mirror fan-out - NAS SVM | # of Clusters that can be peered - Cluster | Volumes, SnapMirror relationship | SnapMirror Synchronous relationships | # of Consistency Groups in SM-BC relationships | # of Constituent Volumes in SM-BC relationships | Flexible Volumes in SVM DR | SVM Disaster recovery - Cluster | # of Concurrent SVM Migration - Cluster | # of Volumes with SVM Migration - SVM | # of Cluster for SVM Migration - Cluster |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Node:36 HA Pair (Non-Scalable):36 | Volume:1 Node:1000 HA Pair:2000 Cluster:15000 | 2 | 100 | 8 | 2 | 255 | FlexGroup:200 FlexGroup-Node:50 HA Pair:1000 Cluster:6000 | Volume:1 Node:400 HA Pair (Non-Scalable):400 | HA Pair (Non-Scalable):50 | Consistency group:16 HA Pair (Non-Scalable):400 | SVM:300 HA Pair:1000 | 128 | 1 | 100 | 6 |
NVMe/oF Cluster Limits - All Maximums
# of Storage virtual machines (SVMs), NVMe/oF - Cluster | # of Flexible volumes, NVMe/oF | # of Flexible volumes with DPO, NVMe/oF | # of Namespaces | # of Subsystems | # of Namespace Mappings | Namespace Size | I/O queue depth available - NVMe/FC - Queue | I/O queue count available - NVMe/FC - Controller | Hosts - Subsystem | LIFS, NVMe/oF | # of Controllers - NVMe/FC - Port | I/O Queue Count, NVMe/TCP - Controller | I/O Queue Depth - NVMe/TCP | Controllers, NVMe/TCP - Node |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
32 | Node:1000 HA Pair:2000 Cluster:12000 | Node:1500 HA Pair:3000 Cluster:12000 | Volume:1024 Node:8192 HA Pair:16384 Cluster:65536 | Node:512 Node:512 | Subsystem:1024 Node:8192 HA Pair:16384 Cluster:65536 | 16 | - | - | 64 | Port:16 SVM:8 Node:32 HA Pair:32 Cluster:32 | - | 2 | 128 | 1024 |
FlexCache Cluster Limits - All Maximums Cache
Degree of fan-out - Origin | Origin Volumes | Constituent Volumes | Volumes | Origin ConstituentVolumes |
---|---|---|---|---|
100 | Node:100 HA Pair:200 | Node:800 HA Pair:1600 | Node:100 HA Pair:200 | Node:800 HA Pair:1600 |
S3 Cluster Limits -
Max # of Buckets | Max # of Objects - Bucket | Max # of Users | Max Size of the Bucket (PB) - Vserver |
---|---|---|---|
Vserver:12000 Cluster:12000 | 400000000000 | Vserver:4000 Cluster:96000 | 20 |
Consistency Groups - All Maximums
Number of Consistency Groups - Cluster | Consistency Groups and Parents Consistency Groups - Cluster | Number of Parent Consistency Groups - Cluster | Child Consistency Groups in a Parent Consistency Groups - Parent Group | Flexible Volumes in a Consistency Group | Flexible Volumes for Child Consistency Groups under a Parent Group | Flexible Volumes in a Child Consistency Group |
---|---|---|---|---|---|---|
15000 | 15000 | 15000 | 5 | 80 | 80 | 80 |
Flex Array Specifications
Third Party Array Compatibility | Array LUN Absolute Min Raw Capacity | Array LUN Block Size | Default Array LUN RAID Group Size | Array LUN Max RAID Groups Per Aggregate | Max Array LUN Size | Max Array LUN Raid Group Size | Min Array LUN Size | Min Array LUN Root Vol Size | Min Array LUN RAID Group Size | Min Array LUN Aggregate Size | Array LUN neighborhood Visible Assigned Devices | Array LUN Recommended Min RAW Capacity | Spare Core Array LUN Min Size |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | - | - | - | - | - | - | - | - | - | - | - | - | - |
Footnotes -
Notes ID | Notes Description |
---|---|
[1] | The root volume and aggregate on this system are significantly smaller than on previous generation systems. Core dump files that used to be written to the root volume are now written to the controller’s boot media, instead. |
Platform LED for AFF A220A 10GBASE-T Single Chassis HA Pair
LED Label | LED Name | Type | Status Indicator | Description | |||||
---|---|---|---|---|---|---|---|---|---|
1 | Chassis Power Config | - | On Green | At least one of the two PSUs is delivering power to the system. | |||||
- | - | - | Off | Neither PSU is delivering power to the system. | |||||
2 | Chassis Attention LED, front | - | On Amber | The system halted or a fault occurred in the chassis. | |||||
- | - | - | Off | The system is operating normally. | |||||
3 | Location LED on chassis front | - | On or flashing blue | The LED has been manually activated to aid in physically locating equipment | |||||
- | - | - | Off | The LED has not been manually activated to aid in physically locating | |||||
Back View | |||||||||
LED Label | LED Name | Type | Status Indicator | Description | |||||
0a | Port SAS 2 LED Onboard Config | Attention | Yellow | SAS link requires attention | |||||
- | - | - | Off | SAS link operates as normal | |||||
- | - | Link | Green | Link is established on at least one external SAS lane | |||||
- | - | - | Off | No link is established on any external SAS lane | |||||
0b | Port SAS 2 LED Onboard Config | Attention | Yellow | SAS link requires attention | |||||
- | - | - | Off | SAS link operates as normal | |||||
- | - | Link | Green | Link is established on at least one external SAS lane | |||||
- | - | - | Off | No link is established on any external SAS lane | |||||
e0a | Port Ethernet SFP Config | Attention | Yellow | Ethernet Port requires attention. | |||||
- | - | - | Off | Ethernet port operates as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0b | Port Ethernet SFP Config | Attention | Yellow | Ethernet Port requires attention. | |||||
- | - | - | Off | Ethernet port operates as normal | |||||
- | - | Link | Green | A connection is established to the port. | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0c | Port Ethernet Config 10GBase-T | Port Activity | Blinking green | Traffic is flowing over the connection | |||||
- | - | - | Off | No traffic is flowing over the connection. | |||||
- | - | Port Link | Green | A connection is established on the port | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0d | Port Ethernet Config 10GBase-T | Port Activity | Blinking green | Traffic is flowing over the connection | |||||
- | - | - | Off | No traffic is flowing over the connection. | |||||
- | - | Port Link | Green | A connection is established on the port | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0e | Port Ethernet Config 10GBase-T | Port Activity | Blinking green | Traffic is flowing over the connection | |||||
- | - | - | Off | No traffic is flowing over the connection. | |||||
- | - | Port Link | Green | A connection is established on the port | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0f | Port Ethernet Config 10GBase-T | Port Activity | Blinking green | Traffic is flowing over the connection | |||||
- | - | - | Off | No traffic is flowing over the connection. | |||||
- | - | Port Link | Green | A connection is established on the port | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0m/BMC | Ethernet On/Off | Port Link | Solid green | On | |||||
- | - | - | Off | No link established |
Supported Shelves Drives for AFF A220A 10GBASE-T Single Chassis HA Pair
Part No. | Capacity | RPM | Drive Type | Encryption | Root-Data Partitioning | Root-Data-Data Partitioning | Storage Pool Partitioning | Max Drive Count | FlexArray |
---|---|---|---|---|---|---|---|---|---|
AFF A220A 10GBASE-T Internal Drives | |||||||||
X319A | 7.6TB | - | SSD | No | No | Yes | No | 24 | No |
X356A-R6 | 3.84TB | - | SSD | No | No | Yes | No | 24 | No |
X357A | 3.84TB | - | SSD | No | No | Yes | No | 24 | No |
X358A [1] | 3.84TB | - | SSD | FIPS 140-2 Level 2, NSE | No | Yes | No | 24 | No |
X359A | 30.6TB | - | SSD | No | No | Yes | No | 24 | No |
X365A-R6 [1] | 1.6TB | - | SSD | FIPS 140-2 Level 2, NSE | No | Yes | No | 24 | No |
X371A | 960GB | - | SSD | No | No | Yes | No | 24 | No |
X386A [1] | 960GB | - | SSD | FIPS 140-2 Level 2, NSE | No | Yes | No | 24 | No |
X438A-R6 | 400GB | - | SSD | No | No | Yes | No | 24 | No |
X439A-R6 | 1.6TB | - | SSD | No | No | Yes | No | 24 | No |
X440A-R6 [1] | 800GB | - | SSD | FIPS 140-2 Level 2, NSE | No | Yes | No | 24 | No |
X440B-R6 [1] | 800GB | - | SSD | FIPS 140-2 Level 2, NSE | No | Yes | No | 24 | No |
X447A-R6 | 800GB | - | SSD | No | No | Yes | No | 24 | No |
X670A | 15.3TB | - | SSD | No | No | Yes | No | 24 | No |
DS224C with IOM12B / IOM12 shelf modules | |||||||||
X319A | 7.6TB | - | SSD | No | No | Yes | No | 120 | No |
X356A-R6 | 3.84TB | - | SSD | No | No | Yes | No | 120 | No |
X357A | 3.84TB | - | SSD | No | No | Yes | No | 120 | No |
X358A [1] | 3.84TB | - | SSD | FIPS 140-2 Level 2, NSE | No | Yes | No | 120 | No |
X359A | 30.6TB | - | SSD | No | No | Yes | No | 120 | No |
X365A-R6 [1] | 1.6TB | - | SSD | FIPS 140-2 Level 2, NSE | No | Yes | No | 120 | No |
X371A | 960GB | - | SSD | No | No | Yes | No | 120 | No |
X386A [1] | 960GB | - | SSD | FIPS 140-2 Level 2, NSE | No | Yes | No | 120 | No |
X438A-R6 | 400GB | - | SSD | No | No | Yes | No | 120 | No |
X439A-R6 | 1.6TB | - | SSD | No | No | Yes | No | 120 | No |
X440A-R6 [1] | 800GB | - | SSD | FIPS 140-2 Level 2, NSE | No | Yes | No | 120 | No |
X440B-R6 [1] | 800GB | - | SSD | FIPS 140-2 Level 2, NSE | No | Yes | No | 120 | No |
X446B-R6 | 200GB | - | SSD | No | No | No | No | 120 | No |
X447A-R6 | 800GB | - | SSD | No | No | Yes | No | 120 | No |
X670A | 15.3TB | - | SSD | No | No | Yes | No | 120 | No |
DS2246 with IOM12 / IOM12B / IOM6 shelf modules | |||||||||
X356A-R6 | 3.84TB | - | SSD | No | No | Yes | No | 120 | No |
X357A | 3.84TB | - | SSD | No | No | Yes | No | 120 | No |
X358A [1] | 3.84TB | - | SSD | FIPS 140-2 Level 2, NSE | No | Yes | No | 120 | No |
X365A-R6 [1] | 1.6TB | - | SSD | FIPS 140-2 Level 2, NSE | No | Yes | No | 120 | No |
X371A | 960GB | - | SSD | No | No | Yes | No | 120 | No |
X438A-R6 | 400GB | - | SSD | No | No | Yes | No | 120 | No |
X439A-R6 | 1.6TB | - | SSD | No | No | Yes | No | 120 | No |
X440A-R6 [1] | 800GB | - | SSD | FIPS 140-2 Level 2, NSE | No | Yes | No | 120 | No |
X440B-R6 [1] | 800GB | - | SSD | FIPS 140-2 Level 2, NSE | No | Yes | No | 120 | No |
X446B-R6 | 200GB | - | SSD | No | No | No | No | 120 | No |
X447A-R6 | 800GB | - | SSD | No | No | Yes | No | 120 | No |
Footnote: | |||||||||
[1] Mixing NSE drives or shelves with any other type of encrypting or non-encrypting drives or shelves across a stand-alone platform or high-availability (HA) pair is not supported. |
Supported RAID Configurations - AFF A220A 10GBASE-T Single Chassis HA Pair
Drive Type | Drive Capacity Min | Drive Capacity Max | Minimum | Default | Maximum | ||||
---|---|---|---|---|---|---|---|---|---|
Data Aggregate | |||||||||
RAID4 | |||||||||
SSD | 0 TB | 30.6 TB | 3 | 8 | 14 | ||||
RAID-DP | |||||||||
SSD | 0 TB | 30.6 TB | 5 | 24 | 28 | ||||
RAID-TEC | |||||||||
SSD | 0 TB | 30.6 TB | 7 | 25 | 29 | ||||
Root Aggregate | |||||||||
RAID-DP | |||||||||
SSD | 0 TB | 30.6 TB | 3[1] | - | 28 | ||||
RAID-TEC | |||||||||
SSD | 0 TB | 30.6 TB | 7 | - | 29 | ||||
Footnote: | |||||||||
[1] The minimum number of disks in a RAID-DP group is three: at least one data disk, one regular parity disk, and one double-parity (dParity) disk. However, for non-root aggregates with only one RAID group, you must have at least 5 disks (three data disks and two parity disks). |
Supported Connections for AFF A220A 10GBASE-T Single Chassis HA Pair
Configuration Type | Port Configuration | Image | Cluster Ports per Node | Switch Ports per Node | |||||
---|---|---|---|---|---|---|---|---|---|
Cluster Interconnect | |||||||||
2-node Switchless Cluster (option 1) | Default | View Image | 2 | None | |||||
2-node Switchless Cluster (option 2) | 10GBASE-T ports e0c/e0e | View Image | 2 | None | |||||
2-node Switchless Cluster (option 3) | 10GBASE-T ports e0d/e0f | View Image | 2 | None | |||||
Switched 10GbE Interconnect | Default, Recommended | View Image | 2 | 2 | |||||
Switched 40GbE Interconnect (10GbE breakout) | Default, Recommended | View Image | 2 | 1 |
Platform Mixing Rules - AFF A220A 10GBASE-T Single Chassis HA Pair
Platform Configuration Type | Maximum Nodes (NAS) [1] | Maximum Nodes (SAN) [1] | Min ONTAP Version for Platform Mixing | ||||||
---|---|---|---|---|---|---|---|---|---|
FAS - Current Configuration(s) | |||||||||
FAS2720A 10GBASE-T | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
FAS2720A UTA2 | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
FAS2750A 10GBASE-T | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
FAS2750A UTA2 | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
FAS500fA | 24 Nodes | 12 Nodes | 9.8RC1 | ||||||
FAS8300A Ethernet Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS8300A FC Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS8700A Ethernet Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS8700A FC Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
FAS9000A | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
FAS9500A | 24 Nodes | 12 Nodes | 9.10.1P3 | ||||||
AllFlashFAS - Current Configuration(s) | |||||||||
AFF A250A | 24 Nodes | 12 Nodes | 9.8RC1 | ||||||
AFF A250A 100V | 24 Nodes | 12 Nodes | 9.8P4 | ||||||
AFF A400A Ethernet Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF A400A FC Bundle | 24 Nodes | 12 Nodes | 9.7RC1 | ||||||
AFF A700A | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
AFF A800A | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
AFF A900A | 24 Nodes | 12 Nodes | 9.10.1 | ||||||
FAS - Legacy EOA Configuration(s) | |||||||||
FAS8200A | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
AllFlashFAS - Legacy EOA Configuration(s) | |||||||||
AFF A220A 10GBASE-T | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
AFF A220A UTA2 | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
AFF A300A | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
AFF A320A | 24 Nodes | 12 Nodes | 9.6RC2 | ||||||
AFF A700s | 24 Nodes | 12 Nodes | 9.4RC1 | ||||||
Footnote: | |||||||||
[1] Maximum number of nodes within a cluster is determined by platform which supports the fewest number of nodes |
Supported OS Version - AFF A220A 10GBASE-T Single Chassis HA Pair
OS Major Version | Supported OS Version | Supported Milestones | Recommend Version | ||||||
---|---|---|---|---|---|---|---|---|---|
Currently Supported OS | |||||||||
ONTAP 9.11.1 | 9.11.1, 9.11.1RC1 | End of Full Support: 31-Jul-2025 End of Limited Support: 31-Jul-2027 End of Self-Service Support: 31-Jul-2030 | 9.11.1 | ||||||
ONTAP 9.10.1 | 9.10.1P5, 9.10.1P7, 9.10.1P6, 9.10.1P4, 9.10.1P3, 9.10.1P2, 9.10.1P1, 9.10.1, 9.10.1RC1 | End of Full Support: 31-Jan-2025 End of Limited Support: 31-Jan-2027 End of Self-Service Support: 31-Jan-2030 | 9.10.1P7, 9.10.1P6 | ||||||
ONTAP 9.9.1 | 9.9.1P11, 9.9.1P10, 9.9.1P9, 9.9.1P8, 9.9.1P7, 9.9.1P6, 9.9.1P5, 9.9.1P4, 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 | End of Full Support: 30-Jun-2024 End of Limited Support: 30-Jun-2026 End of Self-Service Support: 30-Jun-2029 | 9.9.1P11, 9.9.1P10, 9.9.1P9 | ||||||
ONTAP 9.8 | 9.8P13, 9.8P12, 9.8P11, 9.8P10, 9.8P9, 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4, 9.8P3, 9.8P2, 9.8P1, 9.8, 9.8RC1 | End of Full Support: 31-Dec-2023 End of Limited Support: 31-Dec-2025 End of Self-Service Support: 31-Dec-2028 | 9.8P13, 9.8P12 | ||||||
ONTAP 9.7 | 9.7P19, 9.7P18, 9.7P17, 9.7P16, 9.7P15, 9.7P14, 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 | End of Full Support: 31-Jan-2023 End of Limited Support: 31-Jan-2025 End of Self-Service Support: 31-Jan-2028 | 9.7P19 | ||||||
EOS OS | |||||||||
ONTAP 9.7 | 9.7P19, 9.7P18, 9.7P17, 9.7P16, 9.7P15, 9.7P14, 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 | End of Full Support: 31-Jan-2023 End of Limited Support: 31-Jan-2025 End of Self-Service Support: 31-Jan-2028 | 9.7P19 | ||||||
ONTAP 9.6 | 9.6P18, 9.6P17, 9.6P16, 9.6P15, 9.6P14, 9.6P13, 9.6P12, 9.6P11, 9.6P10, 9.6P9, 9.6P8, 9.6P7, 9.6P6, 9.6P5, 9.6P4, 9.6P3, 9.6P2, 9.6P1, 9.6, 9.6RC2, 9.6RC1 | End of Full Support: 30-Jun-2022 End of Limited Support: 30-Jun-2024 End of Self-Service Support: 30-Jun-2027 | 9.6P18 | ||||||
ONTAP 9.5 | 9.5P19, 9.5P18, 9.5P17, 9.5P16, 9.5P15, 9.5P14, 9.5P13, 9.5P12, 9.5P11, 9.5P10, 9.5P9, 9.5P8, 9.5P7, 9.5P6, 9.5P5, 9.5P4, 9.5P3, 9.5P2, 9.5P1, 9.5, 9.5RC1 | End of Full Support: 31-Jan-2022 End of Limited Support: 31-Jan-2024 End of Self-Service Support: 31-Jan-2027 | 9.5P19 | ||||||
Definitions: | |||||||||
[1]End of Full Support: The date marking the end of Full Support for a particular feature version of a NetApp system software and the beginning of Limited Support. Abbreviated as EOES. | |||||||||
[2]End of Limited Support: The date marking the end of Limited Support for a particular feature version of a product and transition to Self-Service Support. Abbreviated as EOVS. | |||||||||
[3]End of Self-Service Support: NetApp does not provide support for a version of a software product, but related documentation is still available on the NetApp Support Site. NetApp customers are expected to utilize documentation to resolve issues. |
Supported Power Cords for AFF A220A 10GBASE-T Single Chassis HA Pair
Marketing Part No. | End 1 / End 2 | Length | Description | |
---|---|---|---|---|
Non-Cabinet Power Cords | ||||
X-50617-00 | IEC60320-C20 / IEC60320-C13 | 2.00 m | Power Cords,In-Cabinet,2m,C20-C13,E-Series | |
X800B-R6 | CEE 7/7 (Schuko) / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Cont Europe/Korea,10A/250V | |
X800C-R6 | BS1363 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,UK/Ireland,10A/250V | |
X800D-R6 | JIS-C-8303 / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,Japan,15A/125V | |
X800E-R6 | NEMA 5-15P / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,North America,15A/125V | |
X800F-R6 | AS/NZS 3112 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Aus/NZ,10A/250V | |
X800G-R6 | SEV 1011 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Switzerland,10A/250V | |
X800H-R6 | IRAM 2073 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Argentina,10A/250V | |
X800I-R6 | GB2099 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,China,10A/250V | |
X800J-R6 | DHCR107-2-D1 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Demark,10A/250V | |
X800K-R6 | SANS 164-1 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,India/S.Africa,10A/250V | |
X800L-R6 | SI32 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Israel,10A/250V | |
X800M-R6 | CEI 23-16 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Italy,10A/250V | |
X800N | EL208 / IEC60320-C13 | 2.50 m | Pwr Cord,10A,250V,2.5m,India | |
X800P-R6 | NEMA 6-15P / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,North America,15A/250V | |
X800T-R6 | CNS 10917-3 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Taiwan,BSMI,15A/125V | |
X800VB-R6 | NBR14136 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Brazil,10A/250V | |
X800W-R6 | CNS10917/CNS690 / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,Taiwan,10A/250V | |
X800Y-R6 | JIS-C-830 / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,Japan,15A/250V | |
In-Cabinet Power Cords | ||||
X-50617-00-0E-C | IEC60320-C13 / IEC60320-C20 | 1.83 m | Power Cord,In-Cabinet,2m,C20-C13,E-Series,0E,-C | |
X1558A-R6 | IEC60320-C14 / IEC60320-C13 | 1.20 m | Pwr Cord,In-Cabinet,48-In,C13-C14,10A/250V | |
X800-42U-35 | IEC60320-C14 / IEC60320-C13 | 0.89 m | Pwr Cord,In-Cabinet,C13-C14,35-inch | |
X800-42U-43 | IEC60320-C14 / IEC60320-C13 | 1.09 m | Pwr Cord,In-Cabinet,C13-C14,43-inch | |
X800-42U-64 | IEC60320-C14 / IEC60320-C13 | 1.63 m | Pwr Cord,In-Cabinet,C13-C14,64-inch | |
X800-42U-R6 | IEC60320-C14 / IEC60320-C13 | 0.68 m | Pwr Cord,In-Cabinet,27-In,C13-C14,10A/250V |
Onboard Ports Configuration: AFF A220A 10GBASE-T Single Chassis HA Pair
Port Address | Description | Supported Protocols | Port Icon | Port Type |
---|---|---|---|---|
0a | Serial-Attached SCSI | SAS 6/12 Gb | SAS | MiniSAS HD |
0b | Serial-Attached SCSI | SAS 6/12 Gb | SAS | MiniSAS HD |
e0a | Ethernet | Ethernet 10Gb | Ethernet | SFP+ |
e0b | Ethernet | Ethernet 10Gb | Ethernet | SFP+ |
e0c | Ethernet | Ethernet 1/10 Gb | Ethernet | RJ45 |
e0d | Ethernet | Ethernet 1/10 Gb | Ethernet | RJ45 |
e0e | Ethernet | Ethernet 1/10 Gb | Ethernet | RJ45 |
e0f | Ethernet | Ethernet 1/10 Gb | Ethernet | RJ45 |
e0m/BMC | Management | Ethernet 10/100/1000 Mb | Wrench | RJ45 |
Serial Interface | USB Serial Console | RS-232 115200bps | USB 2.0 | USB 2.0 Micro-B |
Serial Interface Icon | Serial Console | RS-232 115200bps | Serial Interface | RJ45 |
USB/2 | Storage Host Port | USB 2.0 | USB 2.0 | USB Type A |
Supported Platform Configurations - AFF A220A 10GBASE-T Single Chassis HA Pair
Platform Configuration | Description | Chassis Configuration | Chassis Count | Controller Count (per chassis) | IOXM Count (per chassis) | Rack Units (Per System) | Weight (Per Chassis) | Min ONTAP | |
---|---|---|---|---|---|---|---|---|---|
HA Pair | |||||||||
AFF A220A 10GBASE-T | AFF A220A 10GBASE-T Single Chassis HA Pair | CC | 1 | 2 | 0 | 2 | 42.77 lb (19.4 kg) | 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
AFF A220A UTA2 | AFF A220A UTA2 Single Chassis HA Pair | CC | 1 | 2 | 0 | 2 | 42.77 lb (19.4 kg) | 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
MetroCluster | |||||||||
AFF A220-4NMCIP 10GBASE-T | AFF A220 4-Node MetroCluster IP 10GBASE-T | CC-CC | 2 | 2 | 0 | 4 | 42.77 lb (19.4 kg) | 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 | |
AFF A220-4NMCIP UTA2 | AFF A220 4-Node MetroCluster IP UTA2 | CC-CC | 2 | 2 | 0 | 4 | 42.77 lb (19.4 kg) | 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1 |
Platform Memory Specifications - AFF A220A 10GBASE-T Single Chassis HA Pair
Part Number | Description | Mfg Part Number | Non-Volatile | Qty | Capacity (GB) | NVRAM/NVMEM Used Capacity (GB) | RAM Used Capacity (GB) |
---|---|---|---|---|---|---|---|
X3222A | R7,IC,SODIMM,16GB,x8,ECC,REG | 107-00172 | no | 4 | 16 | 8 | 64 |
Supported Rail Kit for AFF A220A 10GBASE-T Single Chassis HA Pair
Marketing Part No. | Manufacturing Part No. | Description | |
---|---|---|---|
NetApp System Cabinet Rail Kits | |||
X877B-R6 | 111-00596 | Rail Kit II, NetApp Cabinet, R6 | |
X8783A-R6 | 111-01110 | Rail Kit III, NetApp Cabinet, R6 | |
Third-Party Cabinet Rail Kits | |||
X-02659-00 | 113-00232 | Kit,4-Post,Square or Round-Hole, 24"-32" Rail | |
X5526A-R6 | 111-00593 | Kit,4-Post.Square-Hole, 24"-32" Rail | |
X5527A-R6 | 111-00864 | Kit,2-Post,Round-Hole | |
X5529A-R6 | 111-00310 | Kit,4-Post,Swift,Square-Hole, 24"-32" Rail |
Field Replacement Unit Parts - AFF A220A 10GBASE-T Single Chassis HA Pair
Marketing Part No. | Manufacturing Part No. | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Battery | ||||||||||
X1847 | 271-01847 | Lithium System Battery CR2032 | ||||||||
X1847-R6 | 271-01847 | Lithium System Battery CR2032,R6 | ||||||||
X3152A | 111-02499 | ASSY,BATT,2CELL,HLDR,NV,FAS2650 | ||||||||
Bezel | ||||||||||
X80111A | 111-03707 | Bezel,AFF-A220 | ||||||||
Boot Media | ||||||||||
X3320A | 501-01119 | DRIVE,SSD,128GB,mSATA | ||||||||
Cable Management Guide | ||||||||||
X3322A | 111-02809 | SUB ASSY,SM,BKT,CBL MGMNT SET,FAS2650 | ||||||||
Chassis | ||||||||||
X5721A | 111-02889 | SHELF,EMPTY,2 PSU,913W,MIDPLANE II,DS224C | ||||||||
Data Cable | ||||||||||
X-SFP-H10GB-CU1M-R6 | 112-00210 | Cable,10GBase Copper SFP+ 1m | ||||||||
X-SFP-H10GB-CU1M-R6-C | 112-00210 | Cable,10GBase Copper SFP+ 1m,-C | ||||||||
X-SFP-H10GB-CU1M-R6-N-C | 112-00210 | Cable,10GBase Copper SFP+ 1m,-C | ||||||||
X-SFP-H10GB-CU3M-R6 | 112-00211 | Cable,10GBase Copper SFP+ 3m | ||||||||
X-SFP-H10GB-CU3M-R6-C | 112-00211 | Cable,10GBase Copper SFP+ 3m,-C | ||||||||
X-SFP-H10GB-CU3M-R6-N-C | 112-00211 | Cable,10GBase Copper SFP+ 3m,-C | ||||||||
X-SFP-H10GB-CU5M-R6 | 112-00212 | Cable,10GBase Copper SFP+ 5m | ||||||||
X-SFP-H10GB-CU5M-R6-C | 112-00212 | Cable,10GBase Copper SFP+ 5m,-C | ||||||||
X-SFP-H10GB-CU5M-R6-N-C | 112-00212 | Cable,10GBase Copper SFP+ 5m,-C | ||||||||
X1983-1-R6 | 112-00210 | Cable,Twinax CU,SFP+,1M,X1962/X1963/X1967 | ||||||||
X1983-3-R6 | 112-00211 | Cable,Twinax CU,SFP+,3M,X1962/X1963/X1967 | ||||||||
X1983-5-R6 | 112-00212 | Cable,Twinax CU,SFP+,5M,X1962/X1963/X1967 | ||||||||
X6536-R6 | 112-00090 | Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op | ||||||||
X6536-R6-C | 112-00090 | Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op,-C | ||||||||
X6536-R6-N-C | 112-00090 | Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op,-C | ||||||||
X6537-R6 | 112-00091 | Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op | ||||||||
X6537-R6-C | 112-00091 | Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op,-C | ||||||||
X6537-R6-N-C | 112-00091 | Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op,-C | ||||||||
X65420 | 112-00508 | Cable,ASSY,USB 2.0 MICRO-B,USB-A,2M | ||||||||
X6546-R6 | 112-00074 | Cable,Cntlr-Shelf/Switch,30m,LC/SC,Op | ||||||||
X6547-R6 | 112-00073 | Cable,Cntlr-Shelf/Switch,5m,LC/SC,Op | ||||||||
X6553-R6 | 112-00188 | Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op | ||||||||
X6553-R6-C | 112-00188 | Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op,-C | ||||||||
X6553-R6-N-C | 112-00188 | Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op,-C | ||||||||
X6554-R6 | 112-00189 | Cable,Cntlr-Shelf/Switch,15m,LC/LC,Op | ||||||||
X6554-R6-C | 112-00189 | Cable,OPT,50u,2GHz/KM,MM,LC/LC,15M,-C,R6 | ||||||||
X6554-R6-N-C | 112-00189 | Cable,OPT,50u,2GHz/KM,MM,LC/LC,15M,-C,R6,-C | ||||||||
X6560-R6 | 112-00194 | Cable,Ethernet,0.5m RJ45 CAT6 | ||||||||
X6560-R6-C | 112-00194 | Cable,Ethernet,0.5m RJ45 CAT6,-C | ||||||||
X6560-R6-N-C | 112-00194 | Cable,Ethernet,0.5m RJ45 CAT6 | ||||||||
X6561-R6 | 112-00195 | Cable,Ethernet,2m RJ45 CAT6 | ||||||||
X6561-R6-C | 112-00195 | Cable,Ethernet,2m RJ45 CAT6,-C | ||||||||
X6561-R6-N-C | 112-00195 | Cable,Ethernet,2m RJ45 CAT6,-C | ||||||||
X6562-R6 | 112-00196 | Cable,Ethernet,5m RJ45 CAT6 | ||||||||
X6562-R6-C | 112-00196 | Cable,Ethernet,5m RJ45 CAT6,-C | ||||||||
X6562-R6-N-C | 112-00196 | Cable,Ethernet,5m RJ45 CAT6,-C | ||||||||
X6566B-05-N-C | 112-00297 | Cable,Direct Attach CU SFP+ 10G,0.5M,-C | ||||||||
X6566B-05-R6 | 112-00297 | Cable,Direct Attach CU SFP+ 10G,0.5M | ||||||||
X6566B-05-R6-C | 112-00297 | Cable,Direct Attach CU SFP+ 10G,0.5M,-C | ||||||||
X6566B-2-N-C | 112-00299 | Cable,Direct Attach CU SFP+ 10G,2M,-C | ||||||||
X6566B-2-R6 | 112-00299 | Cable,Direct Attach CU SFP+ 10G,2M | ||||||||
X6566B-2-R6-C | 112-00299 | Cable,Direct Attach CU SFP+ 10G,2M,-C | ||||||||
X6566B-3-N-C | 112-00300 | Cable,Direct Attach CU SFP+ 10G,3M,-C | ||||||||
X6566B-3-R6 | 112-00300 | Cable,Direct Attach CU SFP+ 10G,3M | ||||||||
X6566B-3-R6-C | 112-00300 | Cable,Direct Attach CU SFP+ 10G,3M,-C | ||||||||
X6566B-5-N-C | 112-00301 | Cable,Direct Attach CU SFP+ 10G,5M,-C | ||||||||
X6566B-5-R6 | 112-00301 | Cable,Direct Attach CU SFP+ 10G,5M | ||||||||
X6566B-5-R6-C | 112-00301 | Cable,Direct Attach CU SFP+ 10G,5M,-C | ||||||||
X6577-R6 | 112-00238 | Cable,Ethernet,30m RJ45 CAT6 | ||||||||
X6577-R6-C | 112-00238 | Cable,Ethernet,30m RJ45 CAT6,-C | ||||||||
X6577-R6-N-C | 112-00238 | Cable,Ethernet,30m RJ45 CAT6,-C | ||||||||
X6584-R6 | 112-00290 | Cable,Ethernet,1m RJ45 CAT6 | ||||||||
X6584-R6-C | 112-00290 | Cable,Ethernet,1m RJ45 CAT6,-C | ||||||||
X6584-R6-N-C | 112-00290 | Cable,Ethernet,1m RJ45 CAT6,-C | ||||||||
X6585-R6 | 112-00291 | Cable,Ethernet,3m RJ45 CAT6 | ||||||||
X6585-R6-C | 112-00291 | Cable,Ethernet,3m RJ45 CAT6,-C | ||||||||
X6585-R6-N-C | 112-00291 | Cable,Ethernet,3m RJ45 CAT6,-C | ||||||||
X6592-R6 | 112-00246 | Cable,Ethernet,10m RJ45 CAT6 | ||||||||
X6592-R6-N-C | 112-00246 | Cable,Ethernet,10m RJ45 CAT6,-C | ||||||||
X6593-R6 | 112-00247 | Cable,Ethernet,20m RJ45 CAT6 | ||||||||
X6593-R6-C | 112-00247 | Cable,Ethernet,20m RJ45 CAT6,-C | ||||||||
X6593-R6-N-C | 112-00247 | Cable,Ethernet,20m RJ45 CAT6,-C | ||||||||
X66020A-R6 | 112-00429 | Cable,Storage,MiniSAS HD,QSFP,12G,1m | ||||||||
X66020A-R6-C | 112-00429 | Cable,Storage,MiniSAS HD,QSFP,12G,1m,-C | ||||||||
X66021A-R6 | 112-00430 | Cable,Storage,MiniSAS HD,QSFP,12G,2m | ||||||||
X66021A-R6-C | 112-00430 | Cable,Storage,MiniSAS HD,QSFP,12G,2m,-C | ||||||||
X66022A-R6 | 112-00431 | Cable,Storage,MiniSAS HD,QSFP,12G,5m | ||||||||
X66022A-R6-C | 112-00431 | Cable,Storage,MiniSAS HD,QSFP,12G,5m,-C | ||||||||
X66030A | 112-00435 | Cable,12Gb,Mini SAS HD,0.5m | ||||||||
X66030A-C | 112-00435 | Cable,12Gb,Mini SAS HD,0.5m,-C | ||||||||
X66030A-K-N | 112-00435 | Cable,12Gb,Mini SAS HD,0.5m | ||||||||
X66030A-N | 112-00435 | Cable,12Gb,Mini SAS HD,0.5m | ||||||||
X66030A-N-C | 112-00435 | Cable,12Gb,Mini SAS HD,0.5m,-C | ||||||||
X66031A | 112-00436 | Cable,12Gb,Mini SAS HD,1m | ||||||||
X66031A-C | 112-00436 | Cable,12Gb,Mini SAS HD,1m,-C | ||||||||
X66031A-K-N | 112-00436 | Cable,12Gb,Mini SAS HD,1m | ||||||||
X66031A-N | 112-00436 | Cable,12Gb,Mini SAS HD,1m | ||||||||
X66031A-N-C | 112-00436 | Cable,12Gb,Mini SAS HD,1m,-C | ||||||||
X66032A | 112-00437 | Cable,12Gb,Mini SAS HD,2m | ||||||||
X66032A-C | 112-00437 | Cable,12Gb,Mini SAS HD,2m,-C | ||||||||
X66032A-K-N | 112-00437 | Cable,12Gb,Mini SAS HD,2m | ||||||||
X66032A-N | 112-00437 | Cable,12Gb,Mini SAS HD,2m | ||||||||
X66032A-N-C | 112-00437 | Cable,12Gb,Mini SAS HD,2m,-C | ||||||||
X66034A | 112-00439 | Cable,12Gb,Mini SAS HD,5m | ||||||||
X66034A-C | 112-00439 | Cable,12Gb,Mini SAS HD,5m,-C | ||||||||
X66034A-K-N | 112-00439 | Cable,12Gb,Mini SAS HD,5m | ||||||||
X66034A-N | 112-00439 | Cable,12Gb,Mini SAS HD,5m | ||||||||
X66034A-N-C | 112-00439 | Cable,12Gb,Mini SAS HD,5m,-C | ||||||||
X66040A | 112-00449 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m | ||||||||
X66040A-C | 112-00449 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m,-C | ||||||||
X66040A-K-N | 112-00449 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m | ||||||||
X66040A-N | 112-00449 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m | ||||||||
X66040A-N-C | 112-00449 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m,-C | ||||||||
X66041A | 112-00450 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m | ||||||||
X66041A-C | 112-00450 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m,-C | ||||||||
X66041A-K-N | 112-00450 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m | ||||||||
X66041A-N | 112-00450 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m | ||||||||
X66041A-N-C | 112-00450 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m,-C | ||||||||
X66042A | 112-00451 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m | ||||||||
X66042A-C | 112-00451 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m,-C | ||||||||
X66042A-K-N | 112-00451 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m | ||||||||
X66042A-N | 112-00451 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m | ||||||||
X66042A-N-C | 112-00451 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m,-C | ||||||||
X66043A | 112-00452 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m | ||||||||
X66043A-C | 112-00452 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m,-C | ||||||||
X66043A-K-N | 112-00452 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m | ||||||||
X66043A-N | 112-00452 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m | ||||||||
X66043A-N-C | 112-00452 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m,-C | ||||||||
X66044A | 112-00453 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,15m | ||||||||
X66045A | 112-00454 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,30m | ||||||||
X66046A | 112-00455 | Cable,12Gb,SAS Opt,AOC,Mini SAS HD,50m | ||||||||
X66047A | 112-00456 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,5m | ||||||||
X66047A-C | 112-00456 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,5m,-C | ||||||||
X66047A-N-C | 112-00456 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,5m,-C | ||||||||
X66048A | 112-00457 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,30m | ||||||||
X66048A-C | 112-00457 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,30m,-C | ||||||||
X66048A-N-C | 112-00457 | Cable,12Gb,SAS Opt,Mini SAS HD to LC,30m,-C | ||||||||
X66120-3 | 112-00545 | Cable,Direct Attach CU 40G QSFP/4x10G SFP,3m | ||||||||
X66120-3-C | 112-00545 | Cable,Dir. Attach CU 40G QSFP/4x10G SFP,3m,-C | ||||||||
X66120-3-N-C | 112-00545 | Cable,Dir Attach CU 40G QSFP/4x10G SFP,3m,-C | ||||||||
X66120-5 | 112-00546 | Cable,Direct Attach CU 40G QSFP/4x10G SFP,5m | ||||||||
X66120-5-C | 112-00546 | Cable,Dir. Attach CU 40G QSFP/4x10G SFP,5m,-C | ||||||||
X66120-5-N-C | 112-00546 | Cable,Dir Attach CU 40G QSFP/4x10G SFP,5m,-C | ||||||||
X66205-30 | 112-00261 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m | ||||||||
X66205-30-C | 112-00261 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m,-C | ||||||||
X66205-30-N-C | 112-00261 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m,-C | ||||||||
X66205-5 | 112-00260 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m | ||||||||
X66205-5-C | 112-00260 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m,-C | ||||||||
X66205-5-N-C | 112-00260 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m,-C | ||||||||
X66250-15 | 112-00346 | Cable,LC-LC,OM4,15m | ||||||||
X66250-15-C | 112-00346 | Cable,LC-LC,OM4,15m,-C | ||||||||
X66250-15-N-C | 112-00346 | Cable,LC-LC,OM4,15m,-C | ||||||||
X66250-2 | 112-00342 | Cable,LC-LC,OM4,2m | ||||||||
X66250-2-C | 112-00342 | Cable,LC-LC,OM4,2m,-C | ||||||||
X66250-2-N-C | 112-00342 | Cable,LC-LC,OM4,2m,-C | ||||||||
X66250-30 | 112-00347 | Cable,LC-LC,OM4,30m | ||||||||
X66250-30-C | 112-00347 | Cable,LC-LC,OM4,30m,-C | ||||||||
X66250-30-N-C | 112-00347 | Cable,LC-LC,OM4,30m,-C | ||||||||
X66250-5 | 112-00344 | Cable,LC-LC,OM4,5m | ||||||||
X66250-5-C | 112-00344 | Cable,LC-LC,OM4,5m,-C | ||||||||
X66250-5-N-C | 112-00344 | Cable,LC-LC,OM4,5m,-C | ||||||||
Disk Drive Blank-Filler | ||||||||||
X5054-R6 | 108-00224 | BLANK,DSK DRV FILLER,DS2246,R6 | ||||||||
Drive | ||||||||||
X319A | 108-00687 | SSD,7.6TB,12G,DS224C | ||||||||
X356A-R6 | 108-00468 | SSD,3.8TB,DS2246,FAS2552 | ||||||||
X357A | 108-00572 | SSD,3.8TB,12G,DS224C,W/MSW | ||||||||
X358A [1] | 108-00575 | SSD,3.8TB,12G,NSE,DS224C | ||||||||
X359A | 108-00736 | SSD,30.6TB,12G,DS224C | ||||||||
X365A-R6 [1] | 108-00477 | SSD,1.6TB,NSE,DS2246,FAS2552 | ||||||||
X371A | 108-00546 | SSD,960GB,12G,DS224C,W/MSW | ||||||||
X386A [1] | 108-00806 | SSD,960GB,12G,NSE,DS224C | ||||||||
X438A-R6 | 108-00369 | SSD,400GB,DS224x,FAS2552/2240-2 | ||||||||
X439A-R6 | 108-00372 | SSD,1.6TB,DS224x,FAS2552/2240-2 | ||||||||
X440A-R6 [1] | 108-00374 | SSD,800GB,NSE,DS224x,FAS2240-2,FAS2552 | ||||||||
X440B-R6 [1] | 108-00460 | SSD,800GB,12G,NSE,DS224C | ||||||||
X446B-R6 | 108-00323 | SSD,200GB,B,DS224x,FAS2240-2,FAS2552 | ||||||||
X447A-R6 | 108-00260 | SSD,800GB,DS224x,FAS2552/2240-2 | ||||||||
X670A | 108-00530 | SSD,15.3TB,12G,DS224C | ||||||||
Memory Module | ||||||||||
X3222A | 107-00172 | SODIMM,16GB,ECC,FAS2650 | ||||||||
Power Cord | ||||||||||
X-50617-00 | N/A | Jumper Crd,In-Cab,2m,C20-C13,E-Series | ||||||||
X-50617-00-0E-C | N/A | Jumper Crd,In-Cab,2m,C20-C13,E-Series,0E,-C | ||||||||
X1558A-R6 | N/A | Jumper Crd,In-Cab,48-IN,C13-C14 | ||||||||
X1558A-R6-C | N/A | Jumper Crd,In-Cab,48-IN,C13-C14-C | ||||||||
X800-42U-35 | N/A | Jumper Crd,In-Cab,C13-C14,35-inch | ||||||||
X800-42U-35-C | N/A | Jumper Crd,In-Cab,C13-C14,35-inch,-C | ||||||||
X800-42U-35-K-N | N/A | Jumper Crd,In-Cab,C13-C14,35-inch | ||||||||
X800-42U-35-N | N/A | Power Cable,In-Cabinet,C13-C14,35-inch | ||||||||
X800-42U-43 | N/A | Jumper Crd,In-Cab,C13-C14,43-inch | ||||||||
X800-42U-43-C | N/A | Jumper Crd,In-Cab,C13-C14,43-inch,-C | ||||||||
X800-42U-43-K-N | N/A | Jumper Crd,In-Cab,C13-C14,43-inch | ||||||||
X800-42U-43-N | N/A | Power Cable,In-Cabinet,C13-C14,43-inch | ||||||||
X800-42U-64 | N/A | Jumper Crd,In-Cab,C13-C14,64-inch | ||||||||
X800-42U-64-C | N/A | Jumper Crd,In-Cab,C13-C14,64-inch,-C | ||||||||
X800-42U-64-K-N | N/A | Jumper Crd,In-Cab,C13-C14,64-inch | ||||||||
X800-42U-64-N | N/A | Power Cable,In-Cabinet,C13-C14,64-inch | ||||||||
X800-42U-R6 | N/A | Jumper Crd,In-Cab,C13-C14 | ||||||||
X800-42U-R6-C | N/A | Jumper Crd,In-Cab,C13-C14,-C | ||||||||
X800B-R6 | N/A | Power Cable,Continental Europe,R6 | ||||||||
X800B-R6-C | N/A | Power Cable,Continental Europe,-C,R6 | ||||||||
X800C-R6 | N/A | Power Cable,UK and Ireland,R6 | ||||||||
X800C-R6-C | N/A | Power Cable,UK and Ireland,-C,R6 | ||||||||
X800D-R6 | N/A | Power Cable,Japan,R6 | ||||||||
X800D-R6-C | N/A | Power Cable,Japan,-C,R6 | ||||||||
X800E-R6 | N/A | Power Cable,North America,R6 | ||||||||
X800E-R6-C | N/A | Power Cable,North America,-C,R6 | ||||||||
X800F-R6 | N/A | Power Cable,Australia/New Zealand,R6 | ||||||||
X800F-R6-C | N/A | Power Cable,Australia/New Zealand,-C,R6 | ||||||||
X800G-R6 | N/A | Power Cable,Switzerland,R6 | ||||||||
X800G-R6-C | N/A | Power Cable,Switzerland,-C,R6 | ||||||||
X800H-R6 | N/A | Power Cable,Argentina,R6 | ||||||||
X800H-R6-C | N/A | Power Cable,Argentina,-C,R6 | ||||||||
X800I-R6 | N/A | Power Cable,China,R6 | ||||||||
X800I-R6-C | N/A | Power Cable,China,-C,R6 | ||||||||
X800J-R6 | N/A | Power Cable,Denmark,R6 | ||||||||
X800J-R6-C | N/A | Power Cable,Denmark,-C,R6 | ||||||||
X800K-R6 | N/A | Power Cable,India,South Africa,R6 | ||||||||
X800K-R6-C | N/A | Power Cable,India,South Africa,-C,R6 | ||||||||
X800L-R6 | N/A | Power Cable,Israel,R6 | ||||||||
X800L-R6-C | N/A | Power Cable,Israel,-C,R6 | ||||||||
X800M-R6 | N/A | Power Cable,Italy,R6 | ||||||||
X800M-R6-C | N/A | Power Cable,Italy,-C,R6 | ||||||||
X800N | N/A | POWER CABLE,INDIA BIS | ||||||||
X800N-C | N/A | Power Cable,India BIS,-C | ||||||||
X800P-R6 | N/A | Power Cable,North America,250V,R6 | ||||||||
X800P-R6-C | N/A | Power Cable,North America,250V,-C,R6 | ||||||||
X800T-R6 | N/A | Power Cable,Taiwan,BSMI,R6 | ||||||||
X800T-R6-C | N/A | Power Cable,Taiwan,BSMI,-C,R6 | ||||||||
X800VB-R6 | N/A | Power Cable,Brazil,IEC-60906-1-Plug | ||||||||
X800W-R6 | N/A | Power Cable,Taiwan,250V,BSMI,R6 | ||||||||
X800W-R6-C | N/A | Power Cable,Taiwan,250V,BSMI,-C | ||||||||
X800Y-R6 | N/A | Power Cable,Japan,250V/15A | ||||||||
X800Y-R6-C | N/A | Power Cable,Japan,250V/15A,-C | ||||||||
Power Supply Unit | ||||||||||
X5726A | 114-00148 | PSU,913W | ||||||||
Processor Controller Module (PCM) | ||||||||||
X3218A | 111-03965, 111-04373 | Controller,No MEM,CNA,C190,FAS2700 | ||||||||
X3219A | 111-04043 | Controller,No MEM,RJ45,FAS2700 | ||||||||
PSU | ||||||||||
X5726A | 114-00148 | PSU,913W | ||||||||
Transceiver | ||||||||||
X6567-R6 | 332-00378, AFBR-5710PZ-NA1, AFBR-5710PZ-NA2, AFBR-5718PZ, AFBR-5718PZ-NA1, AFBR-5718PZ-NA2, FTLF8519P3BTL-N1, FTLF8519P3BTL-NQ | SFP Optical 1GB Shortwave Multimode | ||||||||
X6567-R6-C | 332-00378, AFBR-5710PZ-NA1, AFBR-5710PZ-NA2, AFBR-5718PZ, AFBR-5718PZ-NA1, AFBR-5718PZ-NA2, FTLF8519P3BTL-N1, FTLF8519P3BTL-NQ | SFP Optical 1GB Shortwave Multimode,-C | ||||||||
X6567-R6-N-C | 332-00378, AFBR-5710PZ-NA1, AFBR-5710PZ-NA2, AFBR-5718PZ, AFBR-5718PZ-NA1, AFBR-5718PZ-NA2, FTLF8519P3BTL-N1, FTLF8519P3BTL-NQ | SFP Optical 1GB Shortwave Multimode,-C | ||||||||
X6568-R6 | 332-00374, FCLF8522P2BTL-N1, FCLF8522P2BTL-NQ | SFP Copper 1GB RJ-45 | ||||||||
X6568-R6-C | 332-00374, FCLF8522P2BTL-N1, FCLF8522P2BTL-NQ | SFP Copper 1GB RJ-45,-C | ||||||||
X6568-R6-N-C | 332-00374, FCLF8522P2BTL-N1, FCLF8522P2BTL-NQ | SFP Copper 1GB RJ-45,-C | ||||||||
X6588-R6 | 332-00278R6, AFBR-57D7AMZ-NA1, AFBR-57D7AMZ-NA2, AFBR-57D7APZ-NA1, AFBR-57D7APZ-NA2, AFBR-57D9AMZ-NA1, AFBR-57D9AMZ-NA2, FTLF8528P2BNV-(N1), FTLF8528P2BNV-(NQ), FTLF8528P3BNV-(N1), FTLF8528P3BNV-N1, FTLF8528P3BNV-NQ | SFP+Optical 8Gb Shortwave | ||||||||
X66250-15-N-C | 112-00346 | Cable,LC-LC,OM4,15m,-C | ||||||||
X66250-2 | 112-00342 | Cable,LC-LC,OM4,2m | ||||||||
X66250-2-C | 112-00342 | Cable,LC-LC,OM4,2m,-C | ||||||||
X66250-2-N-C | 112-00342 | Cable,LC-LC,OM4,2m,-C | ||||||||
X66250-30 | 112-00347 | Cable,LC-LC,OM4,30m | ||||||||
X66250-30-C | 112-00347 | Cable,LC-LC,OM4,30m,-C | ||||||||
X66250-30-N-C | 112-00347 | Cable,LC-LC,OM4,30m,-C | ||||||||
X66250-5 | 112-00344 | Cable,LC-LC,OM4,5m | ||||||||
X66250-5-C | 112-00344 | Cable,LC-LC,OM4,5m,-C | ||||||||
X66250-5-N-C | 112-00344 | Cable,LC-LC,OM4,5m,-C | ||||||||
X66260-30 | 112-00354 | Cable,LC-LC,OPT,OS2,30M | ||||||||
X66260-30-C | 112-00354 | Cable,LC-LC,OPT,OS2,30M,-C | ||||||||
X66260-30-N-C | 112-00354 | Cable,LC-LC,OPT,OS2,30M,-C | ||||||||
X66260-5 | 112-00353 | Cable,LC-LC,OPT,OS2,5M | ||||||||
X66260-5-C | 112-00353 | Cable,LC-LC,OPT,OS2,5M,-C | ||||||||
X66260-5-N-C | 112-00353 | Cable,LC-LC,OPT,OS2,5M,-C | ||||||||
Destage Control Power Module | ||||||||||
X98100A | 111-02591 | DCPM Unit,90XX | ||||||||
Drive | ||||||||||
X302A-R5 | 108-00268 | Disk Drive,1.0TB 7.2k,DS424x,FAS2240-4 | ||||||||
X306A-R5 | 108-00270 | Disk Drive,2.0TB 7.2k,DS424x,2554/2240-4 | ||||||||
X308A-R5 | 108-00277 | Disk Drive,3.0TB 7.2K,DS424x,2554/2240-4 | ||||||||
X309A-R6 [7] | 108-00301 | DSK DRV,3TB 7.2k,NSE,DS424x,FAS2220/2240-4 | ||||||||
X315A-R6 [7] | 108-00368 | DSK DRV,4TB 7.2k,NSE,DS424x,2554/2220/2240-4 | ||||||||
X316A-R6 | 108-00389 | Disk Drive,6TB 7.2k,DS4246,FAS2554 | ||||||||
X317A [7] | 108-00399 | DSK DRV,6TB,7.2K,12G,NSE,DS212C | ||||||||
X318A-R6 | 108-00455 | DSK DRV,8TB,7.2K,12G,DS212C | ||||||||
X319A | 108-00687 | SSD,7.6TB,12G,DS224C | ||||||||
X322A [7] | 108-00551 | DSK DRV,10TB,7.2K,12G,NSE,DS212C | ||||||||
X336A-R6 | 108-00427 | DSK DRV,4TB,7.2K,12G,DS212C | ||||||||
X339A | 108-00426 | DSK DRV,2TB,7.2K,12Gb,DS212C,FAS2620 | ||||||||
X341A-R6 | 108-00430 | DSK DRV,900GB,10K,12G,DS224C | ||||||||
X342A-R6 | 108-00432 | DSK DRV,1.2TB,10K,12G,DS224C | ||||||||
X343A-R6 | 108-00433 | DSK DRV,1.8TB,10K,12G,DS224C | ||||||||
X356A-R6 | 108-00468 | SSD,3.8TB,DS2246,FAS2552 | ||||||||
X357A | 108-00572 | SSD,3.8TB,12G,DS224C,W/MSW | ||||||||
X358A [7] | 108-00575 | SSD,3.8TB,12G,NSE,DS224C | ||||||||
X359A | 108-00736 | SSD,30.6TB,12G,DS224C | ||||||||
X363A-R6 | 108-00467 | SSD,3.8TB,FAS2520/2554 | ||||||||
X364A | 108-00650 | SSD,3.8TB,DS212C,FAS2620,w/MSW | ||||||||
X365A-R6 [7] | 108-00477 | SSD,1.6TB,NSE,DS2246,FAS2552 | ||||||||
X366A-R6 [7] | 108-00470 | SSD,1.6TB,NSE,DS4246,FAS2554 | ||||||||
X371A | 108-00546 | SSD,960GB,12G,DS224C,W/MSW | ||||||||
X374A | 108-00573 | SSD,960GB,12G,DS212C,W/MSW | ||||||||
X375A | 108-00590 | DSK DRV,4TB,7.2K,12G,DS460C | ||||||||
X376A | 108-00591 | DSK DRV,8TB,7.2K,12G,DS460C | ||||||||
X377A | 108-00592 | DSK DRV,10TB,7.2K,12G,DS460C | ||||||||
X378A [7] | 108-00597 | DSK DRV,10TB,7.2K,12G,NSE,DS460C | ||||||||
X379A | 108-00598 | SSD,960GB,12G,DS460C,W/MSW | ||||||||
X380A | 108-00549 | DSK DRV,10TB,7.2K,12G,DS212C | ||||||||
X381A | 108-00550 | Disk Carrier,2x10TB 7.2k,DS4486 | ||||||||
X386A [7] | 108-00806 | SSD,960GB,12G,NSE,DS224C | ||||||||
X387A | 108-00886 | DSK DRV,16TB,7.2K,12G,DS460C | ||||||||
X388A | 108-00885 | DSK DRV,16TB,7.2K,12G,DS212C | ||||||||
X416A-R5 [7] | 108-00223 | Disk Drive,600GB 10k,NSE,DS224x,FAS2240-2 | ||||||||
X417A-R6 [7] | 108-00246 | DSK DRV,900GB,10K,NSE,DS2246,2552/2240-2 | ||||||||
X421A-R5 | 108-00220 | Disk Drive,450GB 10k,DS224x,FAS2240-2 | ||||||||
X422A-R5 | 108-00221 | Disk Drive,600GB 10k,DS224x,2552/2240-2 | ||||||||
X423A-R5 | 108-00222 | DSK DRV,900GB,10K,DS2246,2552/2240-2,R5 | ||||||||
X425A-R6 | 108-00321 | DSK DRV,1.2TB,10K,DS2246,2552/2240-2 | ||||||||
X426A-R6 | 108-00424 | DSK DRV,1.8TB,10K,DS2246,2552/2240-2 | ||||||||
X427A [7] | 108-00476 | DSK DRV,1.8TB,10k,NSE,DS2246,FAS2552 | ||||||||
X427B-R6 [7] | 108-00438 | DSK DRV,1.8TB,10K,12G,NSE,DS224C | ||||||||
X438A-R6 | 108-00369 | SSD,400GB,DS224x,FAS2552/2240-2 | ||||||||
X439A-R6 | 108-00372 | SSD,1.6TB,DS224x,FAS2552/2240-2 | ||||||||
X440A-R6 [7] | 108-00374 | SSD,800GB,NSE,DS224x,FAS2240-2,FAS2552 | ||||||||
X440B-R6 [7] | 108-00460 | SSD,800GB,12G,NSE,DS224C | ||||||||
X441A-R5 | 108-00278 | Solid State Drive,100GB,DS424x | ||||||||
X442A-R5 [8] | 108-00249 | Solid State Drive,100GB,3Gb,DS4243 | ||||||||
X446A-R6 | 108-00257 | SSD,200GB,DS224x,FAS2240-2 | ||||||||
X446B-R6 | 108-00323 | SSD,200GB,B,DS224x,FAS2240-2,FAS2552 | ||||||||
X447A-R6 | 108-00260 | SSD,800GB,DS224x,FAS2552/2240-2 | ||||||||
X448A-R6 | 108-00253 | SSD,200GB,DS4246,FAS2554/2240-4/2220 | ||||||||
X449A-R6 | 108-00319 | SSD,800GB,DS4246,FAS2554/2240-4/2220 | ||||||||
X477A-R6 | 108-00315 | DSK DRV,4TB 7.2k,DS4246,2554/2220/2240-4 | ||||||||
X478A-R5 | 108-00250 | Disk Carrier,2x3TB,DS448x | ||||||||
X480A-R6 | 108-00302 | Disk Carrier,2x4TB 7.2k,DS4486 | ||||||||
X481A-R6 | 108-00398 | Disk Carrier,2x6TB 7.2k,DS4486 | ||||||||
X483A-R6 | 108-00456 | Disk Carrier,2x8TB 7.2k,DS4486 | ||||||||
X488A-R5 | 108-00298 | Disk Drive,900GB 10K,2520/2220 | ||||||||
X489A-R6 | 108-00322 | Disk Drive,1.2TB 10K,2520/2220 | ||||||||
X490A-R6 | 108-00425 | Disk Drive,1.8TB 10K,FAS2520 | ||||||||
X575A-R6 | 108-00370 | SSD,400GB,DS424x,FAS2554/2240-4/2220 | ||||||||
X576A-R6 | 108-00373 | SSD,1.6TB,DS424x,FAS2554/2240-4/2220 | ||||||||
X577A-R6 [7] | 108-00375 | SSD,800GB,NSE,DS4246,FAS2554 | ||||||||
X670A | 108-00530 | SSD,15.3TB,12G,DS224C | ||||||||
Fan | ||||||||||
X98500A | 441-00058 | Fan Assembly,Module,90XX | ||||||||
Hardware Kit | ||||||||||
X90102A | 400-00725 | Hardware Kit,System De-pop Trays | ||||||||
LED USB | ||||||||||
X91400A | 111-02543 | LED Assembly,90XX | ||||||||
Memory Module | ||||||||||
X93141A | 107-00175 | DIMM,16GB (NVS),90XX | ||||||||
X93142A | 107-00176 | DIMM,32GB,90XX,8200,A300 | ||||||||
Power Cord | ||||||||||
X-50617-00 | N/A | Jumper Crd,In-Cab,2m,C20-C13,E-Series | ||||||||
X-50617-00-0E-C | N/A | Jumper Crd,In-Cab,2m,C20-C13,E-Series,0E,-C | ||||||||
X1558A-R6 | N/A | Jumper Crd,In-Cab,48-IN,C13-C14 | ||||||||
X1558A-R6-C | N/A | Jumper Crd,In-Cab,48-IN,C13-C14-C | ||||||||
X800-42U-35 | N/A | Jumper Crd,In-Cab,C13-C14,35-inch | ||||||||
X800-42U-35-C | N/A | Jumper Crd,In-Cab,C13-C14,35-inch,-C | ||||||||
X800-42U-35-K-N | N/A | Jumper Crd,In-Cab,C13-C14,35-inch | ||||||||
X800-42U-35-N | N/A | Power Cable,In-Cabinet,C13-C14,35-inch | ||||||||
X800-42U-43 | N/A | Jumper Crd,In-Cab,C13-C14,43-inch | ||||||||
X800-42U-43-C | N/A | Jumper Crd,In-Cab,C13-C14,43-inch,-C | ||||||||
X800-42U-43-K-N | N/A | Jumper Crd,In-Cab,C13-C14,43-inch | ||||||||
X800-42U-43-N | N/A | Power Cable,In-Cabinet,C13-C14,43-inch | ||||||||
X800-42U-64 | N/A | Jumper Crd,In-Cab,C13-C14,64-inch | ||||||||
X800-42U-64-C | N/A | Jumper Crd,In-Cab,C13-C14,64-inch,-C | ||||||||
X800-42U-64-K-N | N/A | Jumper Crd,In-Cab,C13-C14,64-inch | ||||||||
X800-42U-64-N | N/A | Power Cable,In-Cabinet,C13-C14,64-inch | ||||||||
X800-42U-R6 | N/A | Jumper Crd,In-Cab,C13-C14 | ||||||||
X800-42U-R6-C | N/A | Jumper Crd,In-Cab,C13-C14,-C | ||||||||
X800B-R6 | N/A | Power Cable,Continental Europe,R6 | ||||||||
X800B-R6-C | N/A | Power Cable,Continental Europe,-C,R6 | ||||||||
X800C-R6 | N/A | Power Cable,UK and Ireland,R6 | ||||||||
X800C-R6-C | N/A | Power Cable,UK and Ireland,-C,R6 | ||||||||
X800D-R6 | N/A | Power Cable,Japan,R6 | ||||||||
X800D-R6-C | N/A | Power Cable,Japan,-C,R6 | ||||||||
X800E-R6 | N/A | Power Cable,North America,R6 | ||||||||
X800E-R6-C | N/A | Power Cable,North America,-C,R6 | ||||||||
X800F-R6 | N/A | Power Cable,Australia/New Zealand,R6 | ||||||||
X800F-R6-C | N/A | Power Cable,Australia/New Zealand,-C,R6 | ||||||||
X800G-R6 | N/A | Power Cable,Switzerland,R6 | ||||||||
X800G-R6-C | N/A | Power Cable,Switzerland,-C,R6 | ||||||||
X800H-R6 | N/A | Power Cable,Argentina,R6 | ||||||||
X800H-R6-C | N/A | Power Cable,Argentina,-C,R6 | ||||||||
X800I-R6 | N/A | Power Cable,China,R6 | ||||||||
X800I-R6-C | N/A | Power Cable,China,-C,R6 | ||||||||
X800J-R6 | N/A | Power Cable,Denmark,R6 | ||||||||
X800J-R6-C | N/A | Power Cable,Denmark,-C,R6 | ||||||||
X800K-R6 | N/A | Power Cable,India,South Africa,R6 | ||||||||
X800K-R6-C | N/A | Power Cable,India,South Africa,-C,R6 | ||||||||
X800L-R6 | N/A | Power Cable,Israel,R6 | ||||||||
X800L-R6-C | N/A | Power Cable,Israel,-C,R6 | ||||||||
X800M-R6 | N/A | Power Cable,Italy,R6 | ||||||||
X800M-R6-C | N/A | Power Cable,Italy,-C,R6 | ||||||||
X800P-R6 | N/A | Power Cable,North America,250V,R6 | ||||||||
X800P-R6-C | N/A | Power Cable,North America,250V,-C,R6 | ||||||||
X800T-R6 | N/A | Power Cable,Taiwan,BSMI,R6 | ||||||||
X800T-R6-C | N/A | Power Cable,Taiwan,BSMI,-C,R6 | ||||||||
X800W-R6 | N/A | Power Cable,Taiwan,250V,BSMI,R6 | ||||||||
X800W-R6-C | N/A | Power Cable,Taiwan,250V,BSMI,-C | ||||||||
X800Y-R6 | N/A | Power Cable,Japan,250V/15A | ||||||||
X800Y-R6-C | N/A | Power Cable,Japan,250V/15A,-C | ||||||||
Power Supply Unit | ||||||||||
X97600A | 114-00146 | Power Supply,1600W | ||||||||
X97600A-C | 114-00146 | Power Supply,1600W,-C | ||||||||
X97601A | 114-00146 | Power Supply,1600W | ||||||||
Processor Controller Module (PCM) | ||||||||||
X93400A | 111-03811 | PCM,Memory,mSATA Module,FAS9000 | ||||||||
Transceiver | ||||||||||
X65402 | 332-00389 | QSFP,Opt,40Gb,Shortwave | ||||||||
X65402-C | 332-00389 | QSFP,Opt,40Gb,Shortwave,-C | ||||||||
X65402-N-C | 332-00389 | QSFP,Opt,40Gb,Shortwave,-C | ||||||||
X65403 | 332-00376 | SFP+ Optical,UTA,16GbE LongReach | ||||||||
X65403-C | 332-00376 | SFP+ Optical,UTA,16GbE LongReach,C | ||||||||
X65403-N-C | 332-00376 | SFP+ Optical,UTA,16GbE LongReach,C | ||||||||
X65404 | 332-00436 | SFP28,25GbE,SR | ||||||||
X65404-C | 332-00436 | SFP28,25GbE,SR,-C | ||||||||
X65404-N-C | 332-00436 | SFP28,25GbE,SR,-C | ||||||||
X65405 | 332-00440 | QSFP28,100GbE,SR | ||||||||
X65405-C | 332-00440 | QSFP28,100GbE,SR,-C | ||||||||
X65405-N-C | 332-00440 | QSFP28,100GbE,SR,-C | ||||||||
X65406 | 332-00450 | QSFP28,CWDM4,2KM | ||||||||
X6567-R6 | 332-00378 | SFP Optical 1GB Shortwave Multimode | ||||||||
X6567-R6-C | 332-00378 | SFP Optical 1GB Shortwave Multimode,-C | ||||||||
X6567-R6-N-C | 332-00378 | SFP Optical 1GB Shortwave Multimode,-C | ||||||||
X6589-N-C | 332-00279R6 | SFP+Optical 10Gb Shortwave,-C | ||||||||
X6589-R6 | 332-00279R6 | SFP+Optical 10Gb Shortwave | ||||||||
X6589-R6-C | 332-00279R6 | SFP+ Optical 10Gb Shortwave,-C | ||||||||
X6596-R6 | 332-00331 | SFP+ FC Optical 16Gb | ||||||||
X6596-R6-C | 332-00331 | SFP+ FC Optical 16Gb,-C | ||||||||
X6596-R6-N-C | 332-00331 | SFP+ FC Optical 16Gb,-C | ||||||||
X6599A-N-C | 332-00363 | SFP+ Optical 10Gb Shortwave,-C | ||||||||
X6599A-R6 | 332-00363 | SFP+ Optical 10Gb Shortwave | ||||||||
X6599A-R6-C | 332-00363 | SFP+ Optical 10Gb Shortwave,-C | ||||||||
X6603A | 332-00400 | SFP+ Optical,32Gb FC Shortwave | ||||||||
X6603A-C | 332-00400 | SFP+ Optical,32Gb FC Shortwave,-C | ||||||||
X6603A-N-C | 332-00400 | SFP+ Optical,32Gb FC Shortwave,-C | ||||||||
X6604A | 332-00405 | SFP+ Optical,UTA,10GbE LongReach | ||||||||
X6604A-C | 332-00405 | SFP+ Optical,UTA,10GbE LongReach,-C | ||||||||
X6604A-N-C | 332-00405 | SFP+ Optical,UTA,10GbE LongReach,-C | ||||||||
Footnote: | ||||||||||
[1] | The maximum number of all Ethernet ports on FAS9000 and AFF A700 is 32 per node and 64 per HA pair | |||||||||
[2] | Connecting tape drives or tape libraries to FC or UTA2 ports requires the use of an FC switch. | |||||||||
[3] | Both ports on the X91440A I/O module can be configured as 40GbE or 4 x 10GbE. All combinations are supported. | |||||||||
[4] | The base FAS9000 or AFF A700 configuration includes a 40GbE adapter in slot 4 (four) and a SAS HBA in slot 9 (nine). | |||||||||
[5] | The maximum number of all Ethernet ports on FAS9000 and AFF A700 is 32 per node and 64 per HA pair. When using the fan out cable to break down 40GbE ports into 10GbE ports, each resulting 10GbE port counts against the maximum Ethernet port limit | |||||||||
[6] | Optical breakout cable 4x10GbE configuration supported on both ports. | |||||||||
[7] | Mixing NSE drives or shelves with any other type of encrypting or non-encrypting drives or shelves across a stand-alone platform or high-availability (HA) pair is not supported. | |||||||||
[8] | This drive does not support the sanitization feature. |
Supported Firmware Matrix - AFF A220A 10GBASE-T Single Chassis HA Pair
Major OS Version | OS Version | Firmeware | |||||||
---|---|---|---|---|---|---|---|---|---|
BIOS | |||||||||
ONTAP 9.11.1 | 9.11.1 | 11.15* | |||||||
ONTAP 9.11.1 | 9.11.1RC1 | 11.16, 11.15* | |||||||
ONTAP 9.10.1 | 9.10.1P7, 9.10.1P5-P6 | 11.16, 11.15* | |||||||
ONTAP 9.10.1 | 9.10.1P3-P4, 9.10.1P2, 9.10.1P1 | 11.16, 11.15, 11.13* | |||||||
ONTAP 9.10.1 | 9.10.1, 9.10.1RC1 | 11.16, 11.15, 11.13, 11.11* | |||||||
ONTAP 9.9.1 | 9.9.1P11, 9.9.1P10 | 11.16, 11.15* | |||||||
ONTAP 9.9.1 | 9.9.1P8-P9, 9.9.1P7 | 11.16, 11.15, 11.13* | |||||||
ONTAP 9.9.1 | 9.9.1P4-P6, 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 | 11.16, 11.15, 11.13, 11.11* | |||||||
ONTAP 9.8 | 9.8P13 | 11.16, 11.15* | |||||||
ONTAP 9.8 | 9.8P11-P12 | 11.16, 11.15, 11.13* | |||||||
ONTAP 9.8 | 9.8P10, 9.8P9, 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4 | 11.16, 11.15, 11.13, 11.11* | |||||||
ONTAP 9.8 | 9.8P3, 9.8P2, 9.8P1, 9.8, 9.8RC1 | 11.16, 11.15, 11.13, 11.11, 11.9* | |||||||
ONTAP 9.7 | 9.7P19, 9.7P17-P18, 9.7P16, 9.7P15, 9.7P14 | 11.16, 11.15, 11.13, 11.11* | |||||||
ONTAP 9.7 | 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8 | 11.16, 11.15, 11.13, 11.11, 11.9* | |||||||
ONTAP 9.7 | 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7* | |||||||
ONTAP 9.6 | 9.6P18, 9.6P17, 9.6P16, 9.6P15 | 11.16, 11.15, 11.13, 11.11* | |||||||
ONTAP 9.6 | 9.6P13-P14, 9.6P12 | 11.16, 11.15, 11.13, 11.11, 11.9* | |||||||
ONTAP 9.6 | 9.6P10-P11 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7* | |||||||
ONTAP 9.6 | 9.6P9, 9.6P7-P8, 9.6P5-P6, 9.6P4, 9.6P3 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5* | |||||||
ONTAP 9.6 | 9.6P2, 9.6, 9.6P1, 9.6RC2, 9.6RC1 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5* | |||||||
ONTAP 9.5 | 9.5P19, 9.5P18 | 11.16, 11.15, 11.13, 11.11* | |||||||
ONTAP 9.5 | 9.5P17, 9.5P16, 9.5P15 | 11.16, 11.15, 11.13, 11.11, 11.9* | |||||||
ONTAP 9.5 | 9.5P14 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7* | |||||||
ONTAP 9.5 | 9.5P13, 9.5P12, 9.5P10-P11, 9.5P9, 9.5P8, 9.5P7, 9.5P6, 9.5P5, 9.5P4, 9.5P2-P3, 9.5P1, 9.5, 9.5RC1 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4* | |||||||
ONTAP 9.4 | 9.4P8, 9.4P7, 9.4P6, 9.4P5, 9.4P4, 9.4P3, 9.4P2, 9.4P1 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4, 11.2.1* | |||||||
ONTAP 9.4 | 9.4, 9.4RC1 | 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4, 11.2.1, 11.2* | |||||||
BMC | |||||||||
ONTAP 9.11.1 | 9.11.1, 9.11.1RC1 | 11.8* | |||||||
ONTAP 9.10.1 | 9.10.1P7, 9.10.1P5-P6 | 11.8* | |||||||
ONTAP 9.10.1 | 9.10.1P3-P4, 9.10.1P2, 9.10.1P1, 9.10.1, 9.10.1RC1 | 11.8, 11.7* | |||||||
ONTAP 9.9.1 | 9.9.1P11 | 11.8* | |||||||
ONTAP 9.9.1 | 9.9.1P10, 9.9.1P8-P9, 9.9.1P7, 9.9.1P4-P6 | 11.8, 11.7* | |||||||
ONTAP 9.9.1 | 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 | 11.8, 11.7, 11.6* | |||||||
ONTAP 9.8 | 9.8P13 | 11.8* | |||||||
ONTAP 9.8 | 9.8P11-P12, 9.8P10, 9.8P9, 9.8P8 | 11.8, 11.7* | |||||||
ONTAP 9.8 | 9.8P7, 9.8P6, 9.8P5, 9.8P4, 9.8P3 | 11.8, 11.7, 11.6* | |||||||
ONTAP 9.8 | 9.8P2, 9.8P1 | 11.8, 11.7, 11.6, 11.5P1* | |||||||
ONTAP 9.8 | 9.8, 9.8RC1 | 11.8, 11.7, 11.6, 11.5P1, 11.5* | |||||||
ONTAP 9.7 | 9.7P19, 9.7P17-P18 | 11.8, 11.7* | |||||||
ONTAP 9.7 | 9.7P16, 9.7P15, 9.7P14, 9.7P13 | 11.8, 11.7, 11.6* | |||||||
ONTAP 9.7 | 9.7P12, 9.7P11 | 11.8, 11.7, 11.6, 11.5P1* | |||||||
ONTAP 9.7 | 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6 | 11.8, 11.7, 11.6, 11.5P1, 11.5* | |||||||
ONTAP 9.7 | 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4* | |||||||
ONTAP 9.6 | 9.6P18, 9.6P17 | 11.8, 11.7* | |||||||
ONTAP 9.6 | 9.6P16, 9.6P15 | 11.8, 11.7, 11.6* | |||||||
ONTAP 9.6 | 9.6P13-P14 | 11.8, 11.7, 11.6, 11.5P1* | |||||||
ONTAP 9.6 | 9.6P12, 9.6P10-P11 | 11.8, 11.7, 11.6, 11.5P1, 11.5* | |||||||
ONTAP 9.6 | 9.6P9, 9.6P7-P8, 9.6P5-P6 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4* | |||||||
ONTAP 9.6 | 9.6P4, 9.6P3 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2* | |||||||
ONTAP 9.6 | 9.6P2 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1* | |||||||
ONTAP 9.6 | 9.6, 9.6P1, 9.6RC2, 9.6RC1 | 11.8, 11.7, 11.6, 11.5P1, 11.5*, 11.4, 11.3P2, 11.3P1* | |||||||
ONTAP 9.5 | 9.5P19 | 11.8, 11.7* | |||||||
ONTAP 9.5 | 9.5P18 | 11.8, 11.7, 11.6* | |||||||
ONTAP 9.5 | 9.5P17, 9.5P16 | 11.8, 11.7, 11.6, 11.5P1* | |||||||
ONTAP 9.5 | 9.5P15, 9.5P14 | 11.8, 11.7, 11.6, 11.5P1, 11.5* | |||||||
ONTAP 9.5 | 9.5P13, 9.5P12, 9.5P10-P11 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4* | |||||||
ONTAP 9.5 | 9.5P9, 9.5P8, 9.5P7 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2* | |||||||
ONTAP 9.5 | 9.5P6 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1* | |||||||
ONTAP 9.5 | 9.5P5, 9.5P4, 9.5P2-P3, 9.5P1, 9.5, 9.5RC1 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.2* | |||||||
ONTAP 9.4 | 9.4P8 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1* | |||||||
ONTAP 9.4 | 9.4P7, 9.4P6, 9.4P5, 9.4P4, 9.4P3 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.1P3* | |||||||
ONTAP 9.4 | 9.4P2 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.1P3, 11.1P2* | |||||||
ONTAP 9.4 | 9.4P1, 9.4, 9.4RC1 | 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.1P3, 11.1P2, 11.1* | |||||||
Footnote: | |||||||||
[1]* Indicates that firmware is bundled with Storage OS Version |
Product Certificates - AFF A220A 10GBASE-T Single Chassis HA Pair
Certificate Name | Geo / Region / Country | Associated Products | |||||||
---|---|---|---|---|---|---|---|---|---|
Battery Pack safety reports | |||||||||
Lithium Battery Safety Doc-Section II/Section IB Shipments,Inventus Power Product Model#271-00045AWB | Global | Platforms : AFF A220, AFF A320, AFF A400, AFF A700s, AFF A800, AFF C190, FAS2620, FAS2650, FAS2720, FAS2750, FAS8300, FAS8700 | |||||||
EMI and Safety certificates | |||||||||
Lithium Battery Safety Doc-Section II/Section IB Shipments,Inventus Power Product Model#271-00045AWB | Global | Platforms : AFF A220, AFF A320, AFF A400, AFF A700s, AFF A800, AFF C190, FAS2620, FAS2650, FAS2720, FAS2750, FAS8300, FAS8700 | |||||||
Declaraion of Similarity NAJ-1501 | Global | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 G-K-U-SoR | Gabon,Kenya,SaudiArabia,Uganda | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 (FXN Mexico) BIS | BIS - India | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 (FXN Taiwan) BIS | BIS - India | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 (Jabil Mexico) BIS | BIS - India | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 60950-CB | CB - International | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 62368-CB | CB - International | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 ACMA | ACMA - Australia, New Zealand | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 BSMI | BSMI - Taiwan | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 CSA | CSA - United States, Canada | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 DoC CE | CE - European Union DoC | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 EAC | EAC - Armenia, Belarus, Kazakhstan, Kyrgyzstan, Russia | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 FCC | FCC - United States | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 IRAM | IRAM - Argentina | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 KC | KC - South Korea | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 Morocco | Morocco | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 NOM | NOM - Mexico | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 NRCS | NRCS - South Africa (Safety) | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 SONCAP | SONCAP - Nigeria | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 TBS | TBS - Tanzania | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 UKRSep | UKRSepro - Ukraine | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 VCCI | VCCI - Japan | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 UKCA DOC | VCCI - Japan | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
NAJ-1501 (Jabil Singapore) BIS | TBS - Tanzania | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
PSU 80+ Platinum Certificates | |||||||||
NAJ-1501 (Jabil Singapore) BIS | TBS - Tanzania | Platforms : AFF A200, AFF A220, AFF C190, ASA AFF A220, E2824, E5724, EF280, EF570, FAS2650, FAS2750, SGF6024 | |||||||
DCJ9133-01 Energy Star Report | Global | PSU : X5726A | |||||||
TDPS-900AB A Energy Star Report | Global | PSU : X5726A | |||||||
Voluntary Product Accessibility Template | |||||||||
TDPS-900AB A Energy Star Report | Global | PSU : X5726A | |||||||
VPAT - NetApp AFF A220 and AFF C190 | Global | Platforms : AFF A220, AFF C190 |
Size, Weight, Acoustic, Power AFF A220A 10GBASE-T Single Chassis HA Pair
Associated Part No. | Configuration | Rack Units | Weight | Sound Power | Sound Pressure | Line Voltage Actual (Min to Max) | Amps Typical | Amps Worst | Watts Typical | Watts Worst | BTU / Hr Typical | BTU / Hr Worst |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Embedded Drive Config (Half) | ||||||||||||
AFF-A220-100-C | AFF A220 2 PCM 10GBASE-T 12x960GB SSD | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.24 | 4.67 | 317 | 457 | 1082 | 1560 |
AFF-A220-100-C | AFF A220 2 PCM 10GBASE-T 12x960GB SSD | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.59 | 2.29 | 311 | 448 | 1062 | 1529 |
AFF-A220-100-C | AFF A220 2 PCM UTA2 12x960GB SSD | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.24 | 4.67 | 317 | 457 | 1082 | 1560 |
AFF-A220-100-C | AFF A220 2 PCM UTA2 12x960GB SSD | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.59 | 2.29 | 311 | 448 | 1062 | 1529 |
AFF-A220-102-C | AFF A220 2 PCM 10GBASE-T 3.8TB SSD | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.21 | 4.64 | 314 | 454 | 1072 | 1550 |
AFF-A220-102-C | AFF A220 2 PCM 10GBASE-T 3.8TB SSD | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.58 | 2.28 | 308 | 445 | 1052 | 1519 |
AFF-A220-102-C | AFF A220 2 PCM UTA2 12x3.8TB SSD | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.21 | 4.64 | 314 | 454 | 1072 | 1550 |
AFF-A220-102-C | AFF A220 2 PCM UTA2 12x3.8TB SSD | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.58 | 2.28 | 308 | 445 | 1052 | 1519 |
AFF-A220-104-C | AFF A220 2 PCM 10GBASE-T 12x3.8TB SSD NSE | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.21 | 4.64 | 314 | 454 | 1072 | 1550 |
AFF-A220-104-C | AFF A220 2 PCM 10GBASE-T 12x3.8TB SSD NSE | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.58 | 2.28 | 308 | 445 | 1052 | 1519 |
AFF-A220-104-C | AFF A220 2 PCM UTA2 12x3.8TB SSD NSE | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.21 | 4.64 | 314 | 454 | 1072 | 1550 |
AFF-A220-104-C | AFF A220 2 PCM UTA2 12x3.8TB SSD NSE | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.58 | 2.28 | 308 | 445 | 1052 | 1519 |
AFF-A220-106-C | AFF A220 2 PCM 10GBASE-T 12x7.6TB | 2 | 48.7 lb (22.1 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.32 | 4.75 | 325 | 465 | 1110 | 1587 |
AFF-A220-106-C | AFF A220 2 PCM 10GBASE-T 12x7.6TB | 2 | 48.7 lb (22.1 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.63 | 2.33 | 319 | 456 | 1089 | 1557 |
AFF-A220-106-C | AFF A220 2 PCM UTA2 12x7.6TB | 2 | 48.7 lb (22.1 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.32 | 4.75 | 325 | 465 | 1110 | 1587 |
AFF-A220-106-C | AFF A220 2 PCM UTA2 12x7.6TB | 2 | 48.7 lb (22.1 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.63 | 2.33 | 319 | 456 | 1089 | 1557 |
AFF-A220-108-C | AFF A220 2 PCM 10GBASE-T 12x15.3TB SSD | 2 | 48.7 lb (22.1 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.34 | 4.78 | 327 | 468 | 1117 | 1598 |
AFF-A220-108-C | AFF A220 2 PCM 10GBASE-T 12x15.3TB SSD | 2 | 48.7 lb (22.1 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.64 | 2.35 | 321 | 459 | 1096 | 1567 |
AFF-A220-108-C | AFF A220 2 PCM UTA2 12x15.3TB SSD | 2 | 48.7 lb (22.1 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.34 | 4.78 | 327 | 468 | 1117 | 1598 |
AFF-A220-108-C | AFF A220 2 PCM UTA2 12x15.3TB SSD | 2 | 48.7 lb (22.1 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.64 | 2.35 | 321 | 459 | 1096 | 1567 |
AFF-A220-111-C | AFF A220 2 PCM 10GBASE-T 12x960GB SSD | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.24 | 4.67 | 317 | 457 | 1082 | 1560 |
AFF-A220-111-C | AFF A220 2 PCM 10GBASE-T 12x960GB SSD | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.59 | 2.29 | 311 | 448 | 1062 | 1529 |
AFF-A220-111-C | AFF A220 2 PCM UTA2 12x960GB SSD | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.24 | 4.67 | 317 | 457 | 1082 | 1560 |
AFF-A220-111-C | AFF A220 2 PCM UTA2 12x960GB SSD | 2 | 51.8 lb (23.5 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.59 | 2.29 | 311 | 448 | 1062 | 1529 |
Embedded Drive Config (Full) | ||||||||||||
AFF-A220-101-C | AFF A220 2 PCM 10GBASE-T 24x960GB SSD | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.75 | 5.18 | 367 | 507 | 1253 | 1731 |
AFF-A220-101-C | AFF A220 2 PCM 10GBASE-T 24x960GB SSD | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.84 | 2.54 | 360 | 497 | 1229 | 1697 |
AFF-A220-101-C | AFF A220 2 PCM UTA2 24x960GB SSD | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.75 | 5.18 | 367 | 507 | 1253 | 1731 |
AFF-A220-101-C | AFF A220 2 PCM UTA2 24x960GB SSD | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.84 | 2.54 | 360 | 497 | 1229 | 1697 |
AFF-A220-103-C | AFF A220 2 PCM 10GBASE-T 24x3.8TB SSD | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.69 | 5.12 | 361 | 501 | 1233 | 1710 |
AFF-A220-103-C | AFF A220 2 PCM 10GBASE-T 24x3.8TB SSD | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.81 | 2.51 | 354 | 491 | 1209 | 1676 |
AFF-A220-103-C | AFF A220 2 PCM UTA2 24x3.8TB SSD | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.69 | 5.12 | 361 | 501 | 1233 | 1710 |
AFF-A220-103-C | AFF A220 2 PCM UTA2 24x3.8TB SSD | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.81 | 2.51 | 354 | 491 | 1209 | 1676 |
AFF-A220-105-C | AFF A220 2 PCM 10GBASE-T 24x3.8TB SSD NSE | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.69 | 5.12 | 361 | 501 | 1233 | 1710 |
AFF-A220-105-C | AFF A220 2 PCM 10GBASE-T 24x3.8TB SSD NSE | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.81 | 2.51 | 354 | 491 | 1209 | 1676 |
AFF-A220-105-C | AFF A220 2 PCM UTA2 24x3.8TB SSD NSE | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.69 | 5.12 | 361 | 501 | 1233 | 1710 |
AFF-A220-105-C | AFF A220 2 PCM UTA2 24x3.8TB SSD NSE | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.81 | 2.51 | 354 | 491 | 1209 | 1676 |
AFF-A220-107-C | AFF A220 2 PCM 10GBASE-T 24x7.6TB | 2 | 54.5 lb (24.7 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.91 | 5.35 | 383 | 524 | 1308 | 1789 |
AFF-A220-107-C | AFF A220 2 PCM 10GBASE-T 24x7.6TB | 2 | 54.5 lb (24.7 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.92 | 2.63 | 376 | 514 | 1284 | 1755 |
AFF-A220-107-C | AFF A220 2 PCM UTA2 24x7.6TB | 2 | 54.5 lb (24.7 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.91 | 5.35 | 383 | 524 | 1308 | 1789 |
AFF-A220-107-C | AFF A220 2 PCM UTA2 24x7.6TB | 2 | 54.5 lb (24.7 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.92 | 2.63 | 376 | 514 | 1284 | 1755 |
AFF-A220-109-C | AFF A220 2 PCM 10GBASE-T 24x15.3TB SSD | 2 | 54.5 lb (24.7 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.95 | 5.39 | 387 | 528 | 1321 | 1803 |
AFF-A220-109-C | AFF A220 2 PCM 10GBASE-T 24x15.3TB SSD | 2 | 54.5 lb (24.7 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.94 | 2.65 | 380 | 518 | 1297 | 1768 |
AFF-A220-109-C | AFF A220 2 PCM UTA2 24x15.3TB SSD | 2 | 54.5 lb (24.7 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.95 | 5.39 | 387 | 528 | 1321 | 1803 |
AFF-A220-109-C | AFF A220 2 PCM UTA2 24x15.3TB SSD | 2 | 54.5 lb (24.7 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.94 | 2.65 | 380 | 518 | 1297 | 1768 |
AFF-A220-112-C | AFF A220 2 PCM 10GBASE-T 24x960GB SSD | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.75 | 5.18 | 367 | 507 | 1253 | 1731 |
AFF-A220-112-C | AFF A220 2 PCM 10GBASE-T 24x960GB SSD | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.84 | 2.54 | 360 | 497 | 1229 | 1697 |
AFF-A220-112-C | AFF A220 2 PCM UTA2 24x960GB SSD | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.75 | 5.18 | 367 | 507 | 1253 | 1731 |
AFF-A220-112-C | AFF A220 2 PCM UTA2 24x960GB SSD | 2 | 60.8 lb (27.6 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.84 | 2.54 | 360 | 497 | 1229 | 1697 |