Please remove $0 item(s) from cart - or - Request for Quote

NetApp FAS2750 2-port UTA2 Single Chassis HA Pair Filer Head (FAS2750-UTA2-2P-1C)

 
Price: Request a Quote

Brand:  
MPN:  
FAS2750-UTA2-2P-1C
Type:  
Filer Head
Condition:  
ECS Refurbished & Tested

Request Quote

Note: Please include as much details and relevant options about the item to help us match your request with an accurate price.


-PLEASE CONTACT FOR CUSTOM CONFIGURATIONS. DISK SHELVES, COMPLETE CONFIGURATIONS & TURN KEY SYSTEMS AVAILABLE.
-SPARE PARTS AVAILABLE FOR EACH MODEL. PLEASE ASK FOR PRICING ON SPARE DISK, CONTROLLERS, POWER SUPPLIES, NICs, HBAs, SFPs, Cables, etc.

NetApp FAS2750 2-port UTA2 Single Chassis HA Pair Filer Head (FAS2750-UTA2-2P-1C)

Powered by NetApp® ONTAP® data management software, we can help you build a storage infrastructure that is simple, secure, and trusted. NetApp FAS Storage Arrays provides customers with a balance of performance and capacity.

NetApp FAS2750 specs

Perfectly suited for small and midsized enterprises requiring easy deployment and simplified operations.

  • Maximum raw capacity per HA pair: 1243TB
  • Maximum drives per HA pair: 144
  • NAS scale-out: 1-24 nodes (12 HA pairs)
  • SAN scale-out: 1-12 nodes (6HA pairs)
  • Maximum raw capacity for cluster: 15PB
  • Controller chassis from factor: 2U / 24 internal drives
  • OS version: ONTAP 9.4 RC1 and later
  • Storage protocols supported: FC, FCoE, iSCSI, NFS, pNFS, CIFS/SMB

Flexibly adapt to evolving business needs
Provision storage in minutes.
Go from initial power-on to serving data in less than 10 minutes with provisioning for key business applications.

Simplify ongoing management.
Upgrade software or service storage during regular business hours with zero downtime.

Streamline operations.
Leverage one unified system for SAN and NAS with proven storage efficiency.

Secure and protect your data across your hybrid cloud
On-premise & public clouds, we have you covered
Start small and scale nondisruptively as your data requirements grow, on premises and in the cloud.

The Best Cloud Integration
Connect effortlessly to the cloud with leading integration to Amazon AWS, Microsoft Azure, Google Cloud, and others.

Prevent problems before they affect your business
Optimize your storage environment and reduce costs with the predictive analytics and proactive care of NetApp ® Active IQ® .

Customer proven for diverse workloads
Secure your sensitive information
Protect your data at rest and in transit with our portfolio of security capabilities.

Safeguard against data loss
Efficiently replicate data and accelerate recovery with application-consistent data protection.

Eliminate business disruptions
Maintain access to data at all times during service, failures, and site disasters.

Customer proven, real-world results
IDC Whitepaper validates NetApp customers achieve six-nines availability.

Product Specs

Storage Limits

Max # of Drives (Total) Max # of Internal Drives Max # of NL-SAS Drives Max # of SAS Drives Max # of SATA Drives Max # of SSD Drives Max # of DS212C Shelves Max # of DS2246 Shelves Max # of DS224C Shelves Max # of DS4243 Shelves Max # of DS4246 Shelves Max # of DS460C Shelves
144 24 144 144 144 144 9 external 5 external 1 internal + 5 external 5 external 5 external 2 external

Capacity Limits

Marketing Maximum Raw Capacity - Node HA Pair Cluster Effective Capacity - Node HA Pair Cluster
1963200 1963200 Detailed Matrix 8713663.2 8713663.2 N/A

Core Cluster Limits

Max SVM's - NAS - Node / HA Pair / Cluster Max LIF's - NAS - Node / HA Pair / Cluster Max Connections - NAS - Node / HA Pair(Non-Scalable) Max Flexible Volumes - NAS - Aggregate (Single data Agg. per Node) / Aggregate (Multiple data Agg. per Node) / Node/ HA Pair / Cluster Max Flexible Volumes with DPO - NAS - Node/ HA Pair / Cluster Max Lock Manager Locked Objects - Node/HA Pair/Cluster Max Intercluster LIFs - Node Min Root Aggregate (MiB) - Node Min Root Volume (GiB) - Node Max IPsec Policies - SVM / Cluster Max Auditing-Enabled SVMs - Cluster
N/A / N/A / 512 512 / 512 / 3072 100000 / 100000 N/A / N/A / 1000 / 2000 / 15000 1500 / 3000 / 12000 1200000 / 1200000 / 12288000 8 191488 150 256 / 1500 50

System Maximums and Limits

Max Nodes per Cluster (NAS / SAN) Max FabricPool Size Max Infinite Volume Data Constituent Size Max FlexGroup Data Constituent Size Min Root Volume Size NetApp Volume Encryption
Not Supported / Not Supported 8400 TiB Not Supported 150 GiB  [1] Supported

Processor

Processor Model Processor Architecture Processor Speed Processor Count (Per Node) Processor Count (Per Config) Processor Cores (Per CPU) Processor Cores (Per Node) Processor Cores (Per Config)
64-bit 12-core 1.50 Ghz 64 bit 1.50 Ghz 1 2 12 12 24

Memory

Detailed Memory Matrix NVME (Per Node) NVME (Per Config) NVMEM (Per Node) NVMEM (Per Config) RAM (Per Node) RAM (Per Config)
Platform Memory Specifications 1024 GB 2048 GB 4 GB 8 GB 32 GB 64 GB

Onboard Ports

Full Onboard Ports Matrix Ethernet Ports Fibre Channel Ports UTA2 Ports Expansion Slots SAS Ports
Onboard Ports & Cables 4 x SFP+ (10Gb) - - 4 x MiniSAS HD (12Gb)

Physical Characteristics

Rack Units Chassis Height Chassis Width with Mounting Flanges Chassis Width without Mounting Flanges Chassis Depth with Cable Mgmt Chassis Depth without Cable Mgmt Chassis Weight
2 3.35" (8.5 cm) 18.9" (48 cm) 17.6" (44.7 cm) 24.13" (61.3 cm) 19.02" (48.3 cm) See Below

System Clearance Dimensions

Front Clearance (Cooling) Front Clearance (Maintenance) Rear Clearance (Cooling) Rear Clearance (Maintenance)
6.03" (15.3 cm) 24.03" (61 cm) 6.03" (15.3 cm) 13" (33 cm)

Environmental Requirements

Operating Temp / Humidity / Altitude Storage Temp / Humidity / Altitude Transit Temp / Humidity / Altitude Acoustic Noise - Sound Power / Pressure Input Power Voltage
41 to 113 deg F - 5 to 45 deg C / 8 to 90 % / Up to 10000.0 ft - Up to 3048.0 m -40 to 158 deg F - -40 to 70 deg C / 10 to 95 % / Up to 40000.0 ft - Up to 12192.0 m -40 to 158 deg F - -40 to 70 deg C / 10 to 95 % / Up to 39989.8 ft - Up to 12192 m 6.9 bels / 51 dBA 100 to 120

Storage OS Requirements

Full OS Matrix Recommended Version Minimum OS Maximum OS
View Full OS Report Below 9.11.1 9.11.1RC1 9.11.1

Storage and Firmware

Full Firmware Matrix BIOS BMC
Full Firmware ReportBelow 11.15* 11.8*

Product Standards Compliance

Full Compliance and Certificates Report Cert. EMC/EMI Cert. Safety Cert. Safety/EMC/EMI Cert. Safety/EMC/EMI/RoHS Standard Safety/EMC/EMI Standard Safety
Compliance and Certificates ReportBelow AMCA, FCC, ICES, KC, Morocco, VCCI BIS, CB, CSA, G_K_U-SoR, IRAM, NOM, NRCS, SONCAP, TBS EAC, UKRSEPRO BSMI, CE DoC, UKCA DoC BS-EN-55024, BS-EN55035, CISPR 32, EN55022, EN55024, EN55032, EN55035, EN61000-3-2, EN61000-3-3, FCC Part 15 Class A, IC  more... ANSI/UL60950-1, ANSI/UL62368-1, BS-EN62368-1, CAN/CSA C22.2 No. 60950-1, CAN/CSA C22.2 No. 62368-1, CNS 14336, EN60825-1  more...

NFS Cluster Limits

Max Export Policies Max Export Rules Max NFSv4 Access Control Entries Max Client Objects - Node / HA Pair Max pNFS objects - Node / HA Pair
24000 200000 1024 10000 / 10000 524288 / 524288 / 1048576

WAFL Cluster Limits - All Maximums

Size 64-bit Aggregate (TiB) Size 64-bit Volume (TiB) File size 64-bit Volume (TiB) Snapshot - Volume / Node / HA Pair Char's Snapshot Hard links - File inodes/files - Volume qtrees - Volume / Node / HA Pair / Cluster Concurrent DataMotion for Volumes ops - Node / HA Pair
800 100 16 1023 / 1023000 / 2046000 255 100000 2000000000 4995 / 100000 / 200000 / 400000 16 / 16

Quality of Service Cluster Limits

Max Policy Groups - Cluster Max QoS User Workloads - Cluster
12000 40000

SAN Cluster Limits - All Maximums

SVMs - Node / HA Pair / Cluster Flexible Vol - Node / HA Pair / Cluster Flexible Vol with DPO - Node / HA Pair / Cluster LUNs Vol - Node / HA Pair / Cluster LUN mappings - Node / HA Pair / Cluster LUN size (TiB) - LUN Maximum FC queue depth available SAN Hosts (ITNs) - Port / Node / HA Pair / Cluster LIFS - iSCSI - Port / Portset / Node / HA Pair / Cluster LIFS - FCP - Port / Portset / Node / HA Pair / Cluster igroups - Node / HA Pair / Cluster Initiators - igroup / Node / HA Pair / Cluster Portsets - Node / HA Pair / Cluster iSCSI sessions - Node / HA Pair / Cluster
125 / 250 / 1000 N/A / N/A / 1000 / 2000 / 12000 1500 / 3000 / 12000 1024 / 8192 / 16384 / 65536 8192 / 16384 / 65536 16 2048 512 / 4096 / 8192 / 32768 32 / 32 / 512 / 1024 / 4096 32 / 32 / 512 / 1024 / 4096 2048 / 4096 / 16384 256 / 2048 / 4096 / 16384 2048 / 4096 / 16384 4096 / 8192 / 32768

CIFS Cluster Limits - All Maximums

Connected shares - Node / HA Pair Regular shares - Node / HA Pair / Cluster Open files - Connection / Node / HA Pair Local users - Cluster Local groups - Cluster Local group members - Cluster
Detailed Matrix / 800000 N/A / N/A / 60000 600000 / 600000 / 600000 5000 10000 30000

Data Protection Cluster Limits - All Maximums

NDMP Sessions - Node / HA Pair (Non-Scalable) Data Protection Mirrors - Volume / Node / HA Pair / Cluster Load Sharing Mirrors - NAS SVM Concurrent Snap Mirror / SnapVault transfers - Node DP Mirror fan-out - Volume LS Mirror fan-out - NAS SVM Clusters that can be peered - Cluster Volumes, SnapMirror relationship - FlexGroup / FlexGroup-Node /HA Pair / Cluster SnapMirror Synchronous relationships - Volume / Node / HA Pair (Non-Scalable) Flexible Volumes in SVM DR - SVM / HA Pair SVM Disaster recovery - Cluster
36 / 36 1 / 1000 / 2000 / 15000 2 100 8 2 255 200 / 50 / 1000 / 6000 1 / 20 / 20 300 / 1000 128

NVMe/oF Cluster Limits - All Maximums

Storage virtual machines (SVMs), NVMe/oF - Cluster Flexible volumes, NVMe/oF - Node / HA Pair / Cluster Flexible volumes with DPO, NVMe/oF - Node / HA Pair / Cluster Namespaces - Volume / Node / HA Pair / Cluster Subsystems - SVM / Cluster Namespace Mappings - Subsystem / Node / HA Pair / Cluster Namespace Size Hosts - Subsystem LIFS, NVMe/oF - Port / SVM / Node / HA Pair / Cluster I/O Queue Count, NVMe/TCP - Controller I/O Queue Depth - NVMe/TCP Controllers, NVMe/TCP - Node
32 1000 / 2000 / 12000 1500 / 3000 / 12000 1024 / 8192 / 16384 / 65536 512 / 512 1024 / 8192 / 16384 / 65536 16 64 16 / 8 / 32 / 32 / 32 2 128 1024

FlexCache Cluster Limits - All Maximums Cache

Degree of fan-out - Origin Origin Volumes - Node / HA Pair Constituent Volumes - Node / HA Pair Volumes - Node / HA Pair Origin ConstituentVolumes - Node / HA Pair
100 100 / 200 800 / 1600 100 / 200 800 / 1600

S3 Cluster Limits - All Maximums

Number of Buckets - Vserver / Cluster Number of Objects - Bucket Number of Users - Vserver / Cluster Size of the Bucket (PB) - Vserver
12000 / 12000 400000000000 4000 / 96000 20

Consistency Groups - All Maximums

Number of Consistency Groups - Cluster Number of Parent Consistency Groups - Cluster Consistency Groups and Parents - Cluster Child Consistency Groups in a Parent - Parent Group Flexible Volumes in a Consistency Group Flexible Volumes for Child Consistency Groups under a Parent Group Flexible Volumes in a Child Consistency Group
15000 15000 15000 5 80 80

Platform LED for FAS2750 2-port UTA2 Single Chassis HA Pair

LED Label LED Name Type Status Indicator Description
Front View
1 Chassis Power Config - On Green At least one of the two PSUs is delivering power to the system.
- - - Off Neither PSU is delivering power to the system.
2 Chassis Attention LED, front - On Amber The system halted or a fault occurred in the chassis.
- - - Off The system is operating normally.
3 Location LED on chassis front - On or flashing blue The LED has been manually activated to aid in physically locating equipment
- - - Off The LED has not been manually activated to aid in physically locating equipment
4 Shelf ID Digital Display - Number Displayed Digital Shelf ID
Back View
LED Label LED Name Type Status Indicator Description
- 0a Port SAS 2 LED Onboard Config Attention Yellow SAS link requires attention
- - - Off SAS link operates as normal
- - Link Green Link is established on at least one external SAS lane
- - - Off No link is established on any external SAS lane
- 0b Port SAS 2 LED Onboard Config Attention Yellow SAS link requires attention
- - - Off SAS link operates as normal
- - Link Green Link is established on at least one external SAS lane
- - - Off No link is established on any external SAS lane
- e0a Port Ethernet SFP Config Attention Yellow Ethernet Port requires attention.
- - - Off Ethernet port operates as normal
- - Link Green A connection is established to the port.
- - - Off No connection is established on the port.
- e0b Port Ethernet SFP Config Attention Yellow Ethernet Port requires attention.
- - - Off Ethernet port operates as normal
- - Link Green A connection is established to the port.
- - - Off No connection is established on the port.
- e0c/0c Port UTA2 Config (Ethernet personality) Attention Off Port is operating as normal
- - Link Green A connection is established to the port.
- - - Yellow Port requires attention
- - - Off No connection is established on the port.
- e0c/0c Port UTA2 Config (FC personality) Attention Off Port is operating as normal
- - Link Green A connection is established to the port.
- - - Yellow Port requires attention
- - - Off No connection is established on the port.
- e0d/0d Port UTA2 Config (Ethernet personality) Attention Off Port is operating as normal
- - Link Green A connection is established to the port.
- - - Yellow Port requires attention
- - - Off No connection is established on the port.
- e0d/0d Port UTA2 Config (FC personality) Attention Off Port is operating as normal
- - Link Green A connection is established to the port.
- - - Yellow Port requires attention
- - - Off No connection is established on the port.
- e0m/BMC Ethernet On/Off Port Activity Blinking green Traffic is present on the active link
- - - Off Off
- - Port Link Solid green On
- - - Off No link established

Supported Shelves Drives for FAS2750 2-Port UTA2 Single Chassis HA Pair

Part No.Capacity RPM Drive Type Encryption Root-Data Partitioning Root-Data-Data Partitioning Storage Pool Partitioning Max Drive Count FlexArray
FAS2750A 2-port UTA2 Internal Drives
X319A 7.6TB N/A SSD No No Yes No 24 No
X341A-R6 900GB 10K SAS No Yes No No 24 No
X342A-R6 1.2TB 10K SAS No Yes No No 24 No
X343A-R6 1.8TB 10K SAS No Yes No No 24 No
X356A-R6 3.84TB N/A SSD No No Yes Yes 24 No
X357A 3.84TB N/A SSD No No Yes Yes 24 No
X358A [1] 3.84TB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 24 No
X365A-R6 [1] 1.6TB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 24 No
X371A 960GB N/A SSD No No Yes Yes 24 No
X386A [1] 960GB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 24 No
X416A-R5 [1] 600GB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 24 No
X417A-R6 [1] [2] 900GB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 24 No
X421A-R5 450GB 10K SAS No Yes No No 24 No
X422A-R5 600GB 10K SAS No Yes No No 24 No
X423A-R5 900GB 10K SAS No Yes No No 24 No
X425A-R6 1.2TB 10K SAS No Yes No No 24 No
X426A-R6 1.8TB 10K SAS No Yes No No 24 No
X427A [1] 1.8TB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 24 No
X427B-R6 [1] 1.8TB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 24 No
X438A-R6 400GB N/A SSD No No Yes Yes 24 No
X439A-R6 1.6TB N/A SSD No No Yes Yes 24 No
X440A-R6 [1] 800GB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 24 No
X440B-R6 [1] 800GB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 24 No
X446B-R6 200GB N/A SSD No No No Yes 24 No
X447A-R6 800GB N/A SSD No No Yes Yes 24 No
X670A 15.3TB N/A SSD No No Yes No 24 No
DS212C with IOM12 / IOM12B / IOM12B / IOM12 shelf modules
X302A-R5 1TB 7.2K SATA No Yes No No 108 No
X306A-R5 2TB 7.2K SATA No Yes No No 108 No
X308A-R5 3TB 7.2K SATA No Yes No No 108 No
X315A-R6 [1] [2] 4TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 108 No
X317A [1] 6TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 108 No
X318A-R6 8TB 7.2K NL-SAS No Yes No No 108 No
X322A [1] 10TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 108 No
X336A-R6 4TB 7.2K NL-SAS No Yes No No 108 No
X339A 2TB 7.2K NL-SAS No Yes No No 108 No
X363A-R6 3.84TB N/A SSD No No No Yes 108 No
X364A 3.84TB N/A SSD No No No Yes 108 No
X366A-R6 [1] 1.6TB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 108 No
X374A 960GB N/A SSD No No No Yes 108 No
X380A 10TB 7.2K NL-SAS No Yes No No 108 No
X388A 16TB 7.2K NL-SAS No Yes No No 108 No
X448A-R6 200GB N/A SSD No No No Yes 108 No
X449A-R6 800GB N/A SSD No No No Yes 108 No
X477A-R6 4TB 7.2K NL-SAS No Yes No No 108 No
X488A-R5 900GB 10K SAS No Yes No No 108 No
X489A-R6 1.2TB 10K SAS No Yes No No 108 No
X490A-R6 1.8TB 10K SAS No Yes No No 108 No
X575A-R6 400GB N/A SSD No No No Yes 108 No
X576A-R6 1.6TB N/A SSD No No No Yes 108 No
DS224C with IOM12 / IOM12B / IOM12 / IOM12B shelf modules
X319A 7.6TB N/A SSD No No Yes No 120 No
X341A-R6 900GB 10K SAS No Yes No No 120 No
X342A-R6 1.2TB 10K SAS No Yes No No 120 No
X343A-R6 1.8TB 10K SAS No Yes No No 120 No
X356A-R6 3.84TB N/A SSD No No Yes Yes 120 No
X357A 3.84TB N/A SSD No No Yes Yes 120 No
X358A [1] 3.84TB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 120 No
X365A-R6 [1] 1.6TB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 120 No
X371A 960GB N/A SSD No No Yes Yes 120 No
X386A [1] 960GB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 120 No
X416A-R5 [1] 600GB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X417A-R6 [1] [2] 900GB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X421A-R5 450GB 10K SAS No Yes No No 120 No
X422A-R5 600GB 10K SAS No Yes No No 120 No
X423A-R5 900GB 10K SAS No Yes No No 120 No
X425A-R6 1.2TB 10K SAS No Yes No No 120 No
X426A-R6 1.8TB 10K SAS No Yes No No 120 No
X427A [1] 1.8TB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X427B-R6 [1] 1.8TB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X438A-R6 400GB N/A SSD No No Yes Yes 120 No
X439A-R6 1.6TB N/A SSD No No Yes Yes 120 No
X440A-R6 [1] 800GB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 120 No
X440B-R6 [1] 800GB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 120 No
X446B-R6 200GB N/A SSD No No No Yes 120 No
X447A-R6 800GB N/A SSD No No Yes Yes 120 No
X670A 15.3TB N/A SSD No No Yes No 120 No
DS460C with IOM12 / IOM12B / IOM12B / IOM12 shelf modules
X379A 960GB N/A SSD No No No Yes 20 No
X375A 4TB 7.2K NL-SAS No Yes No No 120 No
X376A 8TB 7.2K NL-SAS No Yes No No 120 No
X377A 10TB 7.2K NL-SAS No Yes No No 120 No
X378A [1] 10TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X387A 16TB 7.2K NL-SAS No Yes No No 120 No
DS2246 with IOM12 / IOM12B / IOM6 / IOM12 / IOM6 / IOM12B shelf modules
X341A-R6 900GB 10K SAS No Yes No No 120 No
X342A-R6 1.2TB 10K SAS No Yes No No 120 No
X343A-R6 1.8TB 10K SAS No Yes No No 120 No
X356A-R6 3.84TB N/A SSD No No Yes Yes 120 No
X357A 3.84TB N/A SSD No No Yes Yes 120 No
X358A [1] 3.84TB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 120 No
X365A-R6 [1] 1.6TB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 120 No
X371A 960GB N/A SSD No No Yes Yes 120 No
X416A-R5 [1] 600GB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X417A-R6 [1] [2] 900GB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X421A-R5 450GB 10K SAS No Yes No No 120 No
X422A-R5 600GB 10K SAS No Yes No No 120 No
X423A-R5 900GB 10K SAS No Yes No No 120 No
X425A-R6 1.2TB 10K SAS No Yes No No 120 No
X426A-R6 1.8TB 10K SAS No Yes No No 120 No
X427A [1] 1.8TB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X427B-R6 [1] 1.8TB 10K SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X438A-R6 400GB N/A SSD No No Yes Yes 120 No
X439A-R6 1.6TB N/A SSD No No Yes Yes 120 No
X440A-R6 [1] 800GB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 120 No
X440B-R6 [1] 800GB N/A SSD FIPS 140-2 Level 2, NSE No Yes Yes 120 No
X446B-R6 200GB N/A SSD No No No Yes 120 No
X447A-R6 800GB N/A SSD No No Yes Yes 120 No
DS4246 with IOM12 / IOM12B / IOM12B / IOM6 / IOM12 / IOM6 shelf modules
X302A-R5 1TB 7.2K SATA No Yes No No 120 No
X306A-R5 2TB 7.2K SATA No Yes No No 120 No
X308A-R5 3TB 7.2K SATA No Yes No No 120 No
X309A-R6 [1] [2] 3TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X315A-R6 [1] [2] 4TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X316A-R6 6TB 7.2K NL-SAS No Yes No No 120 No
X317A [1] 6TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X318A-R6 8TB 7.2K NL-SAS No Yes No No 120 No
X322A [1] 10TB 7.2K NL-SAS FIPS 140-2 Level 2, NSE Yes No No 120 No
X336A-R6 4TB 7.2K NL-SAS No Yes No No 120 No
X363A-R6 3.84TB N/A SSD No No No Yes 120 No
X366A-R6 [1] 1.6TB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 120 No
X374A 960GB N/A SSD No No No Yes 120 No
X380A 10TB 7.2K NL-SAS No Yes No No 120 No
X441A-R5 100GB N/A SSD No No No No 120 No
X442A-R5 [4] 100GB N/A SSD No No No No 120 No
X448A-R6 200GB N/A SSD No No No Yes 120 No
X449A-R6 800GB N/A SSD No No No Yes 120 No
X477A-R6 4TB 7.2K NL-SAS No Yes No No 120 No
X488A-R5 900GB 10K SAS No Yes No No 120 No
X489A-R6 1.2TB 10K SAS No Yes No No 120 No
X490A-R6 1.8TB 10K SAS No Yes No No 120 No
X575A-R6 400GB N/A SSD No No No Yes 120 No
X576A-R6 1.6TB N/A SSD No No No Yes 120 No
X577A-R6 [1] 800GB N/A SSD FIPS 140-2 Level 2, NSE No No Yes 120 No
DS4243 [3] with IOM12 / IOM6 shelf modules
X302A-R5 1TB 7.2K SATA No No No No 120 No
X306A-R5 2TB 7.2K SATA No No No No 120 No
X308A-R5 3TB 7.2K SATA No No No No 120 No
Footnote:
[1] Mixing NSE drives or shelves with any other type of encrypting or non-encrypting drives or shelves across a stand-alone platform or high-availability (HA) pair is not supported.
[2] In Flash Pool NSE SSD drives can only be used with NSE HDD drives.
[3] The DS4243 shelf requires an upgrade to IOM6 or IOM12 Expander Modules starting with ONTAP 9.4RC1 and FAS27x0.
[4] This drive does not support the sanitization feature.

Supported RAID Configurations - FAS2750 2-Port UTA2 Single Chassis HA Pair

Drive Type Drive Capacity Min Drive Capacity Max Minimum Default Maximum
Data Aggregate
RAID4
NL-SAS 0 TB 8 TB 3 7 7
SAS 0 TB 5.999 TB 3 8 14
SATA 0 TB 5.999 TB 3 7 7
SSD 0 TB 15.3 TB 3 8 14
RAID-DP
NL-SAS 0 TB 5.999 TB 5 14 20
NL-SAS 6 TB 10 TB 5 14 14
SAS 0 TB 5.999 TB 5 16 28
SATA 0 TB 5.999 TB 5 14 20
SSD 0 TB 15.3 TB 5 24 28
RAID-TEC
NL-SAS 0 TB 16 TB 7 21 29
SAS 0 TB 8 TB 7 24 29
SATA 0 TB 8 TB 7 21 29
SSD 0 TB 15.3 TB 7 25 29
Root Aggregate
RAID4
NL-SAS 0 TB 8 TB 2 - 7
SAS 0 TB 5.999 TB 2 - 14
SATA 0 TB 5.999 TB 2 - 7
SSD 0 TB 15.3 TB 2 - 14
RAID-DP
NL-SAS 0 TB 5.999 TB 3[1] - 20
NL-SAS 6 TB 16 TB 3[1] - 14
SAS 0 TB 5.999 TB 3[1] - 28
SATA 0 TB 5.999 TB 3[1] - 20
SSD 0 TB 15.3 TB 3[1] - 28
RAID-TEC
NL-SAS 0 TB 16 TB 7 - 29
SAS 0 TB 8 TB 7 - 29
SATA 0 TB 8 TB 7 - 29
SSD 0 TB 15.3 TB 7 - 29
Footnote:
1The minimum number of disks in a RAID-DP group is three: at least one data disk, one regular parity disk, and one double-parity (dParity) disk. However, for non-root aggregates with only one RAID group, you must have at least 5 disks (three data disks and two parity disks).

Supported Adapter Cards - FAS2750 2-port UTA2 Single Chassis HA Pair

Priority Category Bus Type Mktg Part No. Mfg Part No Description Plug Type Optical Module Included? Cables Supported Protocol(s) Min ONTAP Max Qty [1] Priority Slot Assignment
1 Performance Acceleration M.2 PCIe X3311A - 111-03066 Flash Cache,1.0TB,NVMe No N/A 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
Footnote:
[1] Values shown for max quantity are per controller.  HA configurations will support 2x the values shown.

Supported Connections for FAS2750 2-port UTA2 Single Chassis HA Pair

Configuration Type Port Configuration Image Cluster Ports per Node Switch Ports per Node
2-node Switchless Cluster (option 1) Default View Image Above 2 None
2-node Switchless Cluster (option 2) UTA2 ports e0c/e0d View Image Above 2 None
2-node Switchless Cluster (option 3) UTA2 ports e0e/e0f View Image Above 2 None
Switched 10GbE Interconnect Default, Recommended View Image Above 2 2
Switched 40GbE Interconnect (10GbE breakout) Default, Recommended View Image Above 2 1

Platform Mixing Rules - FAS2750 2-port UTA2 Single Chassis HA Pair

Platform Configuration Type Maximum Nodes (NAS) [1] Maximum Nodes (SAN) [1] Min ONTAP Version for Platform Mixing
FAS - Current Configuration(s)
FAS2720A 10GBASE-T 24 Nodes 12 Nodes 9.4RC1
FAS2720A 2-port UTA2 24 Nodes 12 Nodes 9.4RC1
FAS2720A UTA2 24 Nodes 12 Nodes 9.4RC1
FAS2750A 10GBASE-T 24 Nodes 12 Nodes 9.4RC1
FAS2750A 2-port UTA2 24 Nodes 12 Nodes 9.4RC1
FAS2750A UTA2 24 Nodes 12 Nodes 9.4RC1
FAS500fA 24 Nodes 12 Nodes 9.8RC1
FAS8300A Ethernet Bundle 24 Nodes 12 Nodes 9.7RC1
FAS8300A FC Bundle 24 Nodes 12 Nodes 9.7RC1
FAS8700A Ethernet Bundle 24 Nodes 12 Nodes 9.7RC1
FAS8700A FC Bundle 24 Nodes 12 Nodes 9.7RC1
FAS9000A 24 Nodes 12 Nodes 9.4RC1
FAS9500A 24 Nodes 12 Nodes 9.10.1P3
AllFlashFAS - Current Configuration(s)
AFF A250A 24 Nodes 12 Nodes 9.8RC1
AFF A250A 100V 24 Nodes 12 Nodes 9.8P4
AFF A400A Ethernet Bundle 24 Nodes 12 Nodes 9.7RC1
AFF A400A FC Bundle 24 Nodes 12 Nodes 9.7RC1
AFF A700A 24 Nodes 12 Nodes 9.4RC1
AFF A800A 24 Nodes 12 Nodes 9.4RC1
AFF A900A 24 Nodes 12 Nodes 9.10.1
AFF C190A 10GBASE-T 24 Nodes 12 Nodes 9.6RC2
AFF C190A 2-port UTA2 24 Nodes 12 Nodes 9.6RC2
AFF C190A UTA2 24 Nodes 12 Nodes 9.6RC2
FAS - Legacy EOA Configuration(s)
FAS8200A 24 Nodes 12 Nodes 9.4RC1
AllFlashFAS - Legacy EOA Configuration(s)
AFF A220A 10GBASE-T 24 Nodes 12 Nodes 9.4RC1
AFF A220A UTA2 24 Nodes 12 Nodes 9.4RC1
AFF A300A 24 Nodes 12 Nodes 9.4RC1
AFF A320A 24 Nodes 12 Nodes 9.6RC2
AFF A700s 24 Nodes 12 Nodes 9.4RC1
Footnote:
1Maximum number of nodes within a cluster is determined by platform which supports the fewest number of nodes

Product Standard Compliance - FAS2750 2-port UTA2 Single Chassis HA Pair

Standard Description
Certifications EMC/EMI
AMCA Australia and New Zealand (EMC covered by ACMA DoC)
FCC Federal Communications Commission (EMI Declaration of Conformity covering United States and Canada)
ICES ICES
KC Korea Communications Commission (EMC certificate for South Korea)
Morocco Morocco Declaration of Conformity
VCCI EMI Certificate for Japan
Certifications safety
BIS Bureau of Indian Standard (Safety cert for India)
CB Certificate Body issued safety certificate covering International
CSA Canadian Standards Association issued Safety certificate covering North America
G_K_U-SoR Safety certificate for Gabon, Kenya and Uganda
IRAM Instituto Argentino de Normalización y Certificación (safety certificate for Argentina)
NOM Norma Oficial Mexicana (Safety cert for Mexico)
NRCS National Regulator for Compulsory Specifications (Safety cert for South Africa)
SONCAP Standards Organisation of Nigeria Conformity Assessment Programme (Safety cert for Nigeria)
TBS Tanzanian Bureau of Standards (Safety certificate for Tanzania)
Certifications Safety/EMC/EMI
EAC Euro Asia Conformity (EMC and Safety Cert) covering (Russia, Kazakhstan, Belarus, Armenia, Kyrgyzstan Countries)
UKRSEPRO EMC/Safety certificate for Ukraine
Certifications Safety/EMC/EMI/RoHS
BSMI Certificate for Taiwan
CE DoC European Union Declaration of Conformity
UKCA DoC UK Declaration of Conformity
Standards EMC/EMI
BS-EN-55024 EMC standard for Great Britain
BS-EN55035 EMC standard for Great Britain
CISPR 32 EMI
EN55022 EMC Standard fo European Union
EN55024 EMC Standard fo European Union
EN55032 EMI Standard fo European Union
EN55035 EMC Standard for European Union
EN61000-3-2 EMC Standard for European Union
EN61000-3-3 EMC Standard for European Union
FCC Part 15 Class A EMI standard for United States
ICES-003 EMI Standard for Canada
KS C 9832 EMI Standard for South Korea
KS C 9835 EMC Standard for South Korea
Standards Safety
ANSI/UL60950-1 Safety standard for United States
ANSI/UL62368-1 Safety standard for United States
BS-EN62368-1 Safety standard for Great Britain
CAN/CSA C22.2 No. 60950-1 Safety Standard for Canada
CAN/CSA C22.2 No. 62368-1 Safety Standard for Canada
CNS 14336 Safety Standard for Taiwan
EN60825-1 Laser Safety standard for European Union
EN62368-1 Safety standard for European Union
IEC 62368-1 Safety Standard for International
IEC60950-1 Safety standard for International
IS 13252(part 1) Safety Standard for India

Supported OS Version - FAS2750 2-port UTA2 Single Chassis HA Pair

OS Major Version Supported OS Version Supported Milestones Recommend Version
Currently Supported OS
ONTAP 9.11.1 9.11.1, 9.11.1RC1 End of Full Support: 31-Jul-2025
End of Limited Support: 31-Jul-2027
End of Self-Service Support: 31-Jul-2030
9.11.1
ONTAP 9.10.1 9.10.1P5, 9.10.1P6, 9.10.1P4, 9.10.1P3, 9.10.1P2, 9.10.1P1, 9.10.1, 9.10.1RC1 End of Full Support: 31-Jan-2025
End of Limited Support: 31-Jan-2027
End of Self-Service Support: 31-Jan-2030
9.10.1P6
ONTAP 9.9.1 9.9.1P10, 9.9.1P9, 9.9.1P8, 9.9.1P7, 9.9.1P6, 9.9.1P5, 9.9.1P4, 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 End of Full Support: 30-Jun-2024
End of Limited Support: 30-Jun-2026
End of Self-Service Support: 30-Jun-2029
9.9.1P10, 9.9.1P9
ONTAP 9.8 9.8P13, 9.8P12, 9.8P11, 9.8P10, 9.8P9, 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4, 9.8P3, 9.8P2, 9.8P1, 9.8, 9.8RC1 End of Full Support: 31-Dec-2023
End of Limited Support: 31-Dec-2025
End of Self-Service Support: 31-Dec-2028
9.8P13, 9.8P12
ONTAP 9.7 9.7P19, 9.7P18, 9.7P17, 9.7P16, 9.7P15, 9.7P14, 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 End of Full Support: 31-Jan-2023
End of Limited Support: 31-Jan-2025
End of Self-Service Support: 31-Jan-2028
9.7P19
EOS OS
ONTAP 9.7 9.7P19, 9.7P18, 9.7P17, 9.7P16, 9.7P15, 9.7P14, 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 End of Full Support: 31-Jan-2023
End of Limited Support: 31-Jan-2025
End of Self-Service Support: 31-Jan-2028
9.7P19
ONTAP 9.6 9.6P18, 9.6P17, 9.6P16, 9.6P15, 9.6P14, 9.6P13, 9.6P12, 9.6P11, 9.6P10, 9.6P9, 9.6P8, 9.6P7, 9.6P6, 9.6P5, 9.6P4, 9.6P3, 9.6P2, 9.6P1, 9.6, 9.6RC2, 9.6RC1 End of Full Support: 30-Jun-2022
End of Limited Support: 30-Jun-2024
End of Self-Service Support: 30-Jun-2027
9.6P18
ONTAP 9.5 9.5P19, 9.5P18, 9.5P17, 9.5P16, 9.5P15, 9.5P14, 9.5P13, 9.5P12, 9.5P11, 9.5P10, 9.5P9, 9.5P8, 9.5P7, 9.5P6, 9.5P5, 9.5P4, 9.5P3, 9.5P2, 9.5P1, 9.5, 9.5RC1 End of Full Support: 31-Jan-2022
End of Limited Support: 31-Jan-2024
End of Self-Service Support: 31-Jan-2027
9.5P19
Definitions:
[1]End of Full Support: The date marking the end of Full Support for a particular feature version of a NetApp system software and the beginning of Limited Support. Abbreviated as EOES.
[2]End of Limited Support: The date marking the end of Limited Support for a particular feature version of a product and transition to Self-Service Support. Abbreviated as EOVS.
[3]End of Self-Service Support: NetApp does not provide support for a version of a software product, but related documentation is still available on the NetApp Support Site. NetApp customers are expected to utilize documentation to resolve issues.

Supported Power Cords for FAS2750 2-port UTA2 Single Chassis HA Pair

Marketing Part No.End 1 / End 2LengthDescription
Non-Cabinet Power Cords
X-50617-00 IEC60320-C20 / IEC60320-C13 2.00 m Power Cords,In-Cabinet,2m,C20-C13,E-Series
X800B-R6 CEE 7/7 (Schuko) / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Cont Europe/Korea,10A/250V
X800C-R6 BS1363 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,UK/Ireland,10A/250V
X800D-R6 JIS-C-8303 / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,Japan,15A/125V
X800E-R6 NEMA 5-15P / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,North America,15A/125V
X800F-R6 AS/NZS 3112 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Aus/NZ,10A/250V
X800G-R6 SEV 1011 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Switzerland,10A/250V
X800H-R6 IRAM 2073 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Argentina,10A/250V
X800I-R6 GB2099 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,China,10A/250V
X800J-R6 DHCR107-2-D1 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Demark,10A/250V
X800K-R6 SANS 164-1 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,India/S.Africa,10A/250V
X800L-R6 SI32 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Israel,10A/250V
X800M-R6 CEI 23-16 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Italy,10A/250V
X800N EL208 / IEC60320-C13 2.50 m Pwr Cord,10A,250V,2.5m,India
X800P-R6 NEMA 6-15P / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,North America,15A/250V
X800T-R6 CNS 10917-3 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Taiwan,BSMI,15A/125V
X800VB-R6 NBR14136 / IEC60320-C13 2.50 m Pwr Cord,Non-Cabinet,Brazil,10A/250V
X800W-R6 CNS10917/CNS690 / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,Taiwan,10A/250V
X800Y-R6 JIS-C-830 / IEC60320-C13 1.83 m Pwr Cord,Non-Cabinet,Japan,15A/250V
In-Cabinet Power Cords
X-50617-00-0E-C IEC60320-C13 / IEC60320-C20 1.83 m Power Cord,In-Cabinet,2m,C20-C13,E-Series,0E,-C
X1558A-R6 IEC60320-C14 / IEC60320-C13 1.20 m Pwr Cord,In-Cabinet,48-In,C13-C14,10A/250V
X800-42U-35 IEC60320-C14 / IEC60320-C13 0.89 m Pwr Cord,In-Cabinet,C13-C14,35-inch
X800-42U-43 IEC60320-C14 / IEC60320-C13 1.09 m Pwr Cord,In-Cabinet,C13-C14,43-inch
X800-42U-64 IEC60320-C14 / IEC60320-C13 1.63 m Pwr Cord,In-Cabinet,C13-C14,64-inch
X800-42U-R6 IEC60320-C14 / IEC60320-C13 0.68 m Pwr Cord,In-Cabinet,27-In,C13-C14,10A/250V

Onboard Ports Configuration: FAS2750 2-port UTA2 Single Chassis HA Pair

Port Address Description Supported Protocols Port Icon Port Type
0a Serial-Attached SCSI SAS 6/12 Gb SAS MiniSAS HD
0b Serial-Attached SCSI SAS 6/12 Gb SAS MiniSAS HD
e0a Ethernet Ethernet 10Gb Ethernet SFP+
e0b Ethernet Ethernet 10Gb Ethernet SFP+
e0c/0c [1] Unified Target Adapter 2 Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb Ethernet/Fibre Channel SFP+
e0d/0d [1] Unified Target Adapter 2 Ethernet 1/10 Gb, Fibre Channel 4/8/16 Gb Ethernet/Fibre Channel SFP+
e0m/BMC Management Ethernet 10/100/1000 Mb Wrench RJ45
Serial Interface USB Serial Console RS-232 115200bps USB 2.0 USB 2.0 Micro-B
Serial Interface Icon Serial Console RS-232 115200bps Serial Interface RJ45
USB/2 Storage Host Port USB 2.0 USB 2.0 USB Type A
Footnote:
1Connecting tape drives or tape libraries to the FC or UTA2 ports requires the use of a FC switch.

Supported Platform Configurations - FAS2750 2-port UTA2 Single Chassis HA Pair

Platform Configuration Description Chassis Configuration Chassis Count Controller Count (per chassis) IOXM Count (per chassis) Rack Units (Per System) Weight (Per Chassis) Min ONTAP
HA Pair
FAS2750A 10GBASE-T FAS2750 10GBASE-T Single Chassis HA Pair CC 1 2 0 2 42.77 lb (19.4 kg) 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
FAS2750A 2-port UTA2 FAS2750A 2-port UTA2 CC 1 2 0 2 42.77 lb (19.4 kg) 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
FAS2750A UTA2 FAS2750 UTA2 Single Chassis HA Pair CC 1 2 0 2 42.77 lb (19.4 kg) 9.4RC1, 9.5RC1, 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
MetroCluster
FAS2750-4NMCIP 10GBASE-T FAS2750 4-Node MetroCluster IP 10GBASE-T CC-CC 2 2 0 4 42.77 lb (19.4 kg) 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1
FAS2750-4NMCIP UTA2 FAS2750 4-Node Metro Cluster IP UTA2 CC-CC 2 2 0 4 42.77 lb (19.4 kg) 9.6RC1, 9.7RC1, 9.8RC1, 9.9.1RC1, 9.10.1RC1, 9.11.1RC1

Platform Memory Specifications - FAS2750 2-port UTA2 Single Chassis HA Pair

Part Number Description Mfg Part Number Non-Volatile Qty Capacity (GB) NVRAM/NVMEM Used Capacity (GB) RAM Used Capacity (GB)
X3222A R7,IC,SODIMM,16GB,x8,ECC,REG 107-00172 no 4 16 8 64

Supported Rail Kit for FAS2750 2-port UTA2 Single Chassis HA Pair

Marketing Part No.Manufacturing Part No.Description
NetApp System Cabinet Rail Kits
X877B-R6 111-00596 Rail Kit II, NetApp Cabinet, R6
X8783A-R6 111-01110 Rail Kit III, NetApp Cabinet, R6
Third-Party Cabinet Rail Kits
X-02659-00 113-00232 Kit,4-Post,Square or Round-Hole, 24"-32" Rail
X5526A-R6 111-00593 Kit,4-Post.Square-Hole, 24"-32" Rail
X5527A-R6 111-00864 Kit,2-Post,Round-Hole
X5529A-R6 111-00310 Kit,4-Post,Swift,Square-Hole, 24"-32" Rail

Field Replacement Unit Parts - FAS2720 10GBASE-T Single Chassis HA Pair

Marketing Part No.Manufacturing Part No.Description
Adapter Card
X3311A 111-03066 SUB ASSY,NVME,FLASH,1.0TB
Battery
X1847 271-01847 Lithium System Battery CR2032
X1847-R6 271-01847 Lithium System Battery CR2032,R6
X3152A 111-02499 ASSY,BATT,2CELL,HLDR,NV,FAS2650
Bezel
X80109A 111-02980 Bezel,FAS2750
Blank
X5055-R6 111-00812 BLANK,CHASSIS FILLER,REAR,DS2246,R6
Boot Media
X3320A 501-01119 DRIVE,SSD,128GB,mSATA
Cable Management Guide
X3322A 111-02809 SUB ASSY,SM,BKT,CBL MGMNT SET,FAS2650
Chassis
X5721A 111-02889 SHELF,EMPTY,2 PSU,913W,MIDPLANE II,DS224C
Data Cable
X-SFP-H10GB-CU1M-R6 112-00210 Cable,10GBase Copper SFP+ 1m
X-SFP-H10GB-CU1M-R6-C 112-00210 Cable,10GBase Copper SFP+ 1m,-C
X-SFP-H10GB-CU1M-R6-N-C 112-00210 Cable,10GBase Copper SFP+ 1m,-C
X-SFP-H10GB-CU3M-R6 112-00211 Cable,10GBase Copper SFP+ 3m
X-SFP-H10GB-CU3M-R6-C 112-00211 Cable,10GBase Copper SFP+ 3m,-C
X-SFP-H10GB-CU3M-R6-N-C 112-00211 Cable,10GBase Copper SFP+ 3m,-C
X-SFP-H10GB-CU5M-R6 112-00212 Cable,10GBase Copper SFP+ 5m
X-SFP-H10GB-CU5M-R6-C 112-00212 Cable,10GBase Copper SFP+ 5m,-C
X-SFP-H10GB-CU5M-R6-N-C 112-00212 Cable,10GBase Copper SFP+ 5m,-C
X1983-1-R6 112-00210 Cable,Twinax CU,SFP+,1M,X1962/X1963/X1967
X1983-3-R6 112-00211 Cable,Twinax CU,SFP+,3M,X1962/X1963/X1967
X1983-5-R6 112-00212 Cable,Twinax CU,SFP+,5M,X1962/X1963/X1967
X6536-R6 112-00090 Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op
X6536-R6-C 112-00090 Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op,-C
X6536-R6-N-C 112-00090 Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op,-C
X6537-R6 112-00091 Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op
X6537-R6-C 112-00091 Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op,-C
X6537-R6-N-C 112-00091 Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op,-C
X65420 112-00508 Cable,ASSY,USB 2.0 MICRO-B,USB-A,2M
X6546-R6 112-00074 Cable,Cntlr-Shelf/Switch,30m,LC/SC,Op
X6547-R6 112-00073 Cable,Cntlr-Shelf/Switch,5m,LC/SC,Op
X6553-R6 112-00188 Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op
X6553-R6-C 112-00188 Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op,-C
X6553-R6-N-C 112-00188 Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op,-C  
X6554-R6 112-00189 Cable,Cntlr-Shelf/Switch,15m,LC/LC,Op
X6554-R6-C 112-00189 Cable,OPT,50u,2GHz/KM,MM,LC/LC,15M,-C,R6
X6554-R6-N-C 112-00189 Cable,OPT,50u,2GHz/KM,MM,LC/LC,15M,-C,R6,-C
X6560-R6 112-00194 Cable,Ethernet,0.5m RJ45 CAT6
X6560-R6-C 112-00194 Cable,Ethernet,0.5m RJ45 CAT6,-C
X6560-R6-N-C 112-00194 Cable,Ethernet,0.5m RJ45 CAT6
X6561-R6 112-00195 Cable,Ethernet,2m RJ45 CAT6
X6561-R6-C 112-00195 Cable,Ethernet,2m RJ45 CAT6,-C
X6561-R6-N-C 112-00195 Cable,Ethernet,2m RJ45 CAT6,-C
X6562-R6 112-00196 Cable,Ethernet,5m RJ45 CAT6
X6562-R6-C 112-00196 Cable,Ethernet,5m RJ45 CAT6,-C
X6562-R6-N-C 112-00196 Cable,Ethernet,5m RJ45 CAT6,-C
X6566B-05-N-C 112-00297 Cable,Direct Attach CU SFP+ 10G,0.5M,-C
X6566B-05-R6 112-00297 Cable,Direct Attach CU SFP+ 10G,0.5M
X6566B-05-R6-C 112-00297 Cable,Direct Attach CU SFP+ 10G,0.5M,-C
X6566B-2-N-C 112-00299 Cable,Direct Attach CU SFP+ 10G,2M,-C
X6566B-2-R6 112-00299 Cable,Direct Attach CU SFP+ 10G,2M
X6566B-2-R6-C 112-00299 Cable,Direct Attach CU SFP+ 10G,2M,-C
X6566B-3-N-C 112-00300 Cable,Direct Attach CU SFP+ 10G,3M,-C
X6566B-3-R6 112-00300 Cable,Direct Attach CU SFP+ 10G,3M
X6566B-3-R6-C 112-00300 Cable,Direct Attach CU SFP+ 10G,3M,-C
X6566B-5-N-C 112-00301 Cable,Direct Attach CU SFP+ 10G,5M,-C
X6566B-5-R6 112-00301 Cable,Direct Attach CU SFP+ 10G,5M
X6566B-5-R6-C 112-00301 Cable,Direct Attach CU SFP+ 10G,5M,-C
X6577-R6 112-00238 Cable,Ethernet,30m RJ45 CAT6
X6577-R6-C 112-00238 Cable,Ethernet,30m RJ45 CAT6,-C
X6577-R6-N-C 112-00238 Cable,Ethernet,30m RJ45 CAT6,-C
X6584-R6 112-00290 Cable,Ethernet,1m RJ45 CAT6
X6584-R6-C 112-00290 Cable,Ethernet,1m RJ45 CAT6,-C
X6584-R6-N-C 112-00290 Cable,Ethernet,1m RJ45 CAT6,-C
X6585-R6 112-00291 Cable,Ethernet,3m RJ45 CAT6
X6585-R6-C 112-00291 Cable,Ethernet,3m RJ45 CAT6,-C
X6585-R6-N-C 112-00291 Cable,Ethernet,3m RJ45 CAT6,-C
X6592-R6 112-00246 Cable,Ethernet,10m RJ45 CAT6
X6592-R6-N-C 112-00246 Cable,Ethernet,10m RJ45 CAT6,-C
X6593-R6 112-00247 Cable,Ethernet,20m RJ45 CAT6
X6593-R6-C 112-00247 Cable,Ethernet,20m RJ45 CAT6,-C
X6593-R6-N-C 112-00247 Cable,Ethernet,20m RJ45 CAT6,-C
X66020A-R6 112-00429 Cable,Storage,MiniSAS HD,QSFP,12G,1m
X66020A-R6-C 112-00429 Cable,Storage,MiniSAS HD,QSFP,12G,1m,-C
X66021A-R6 112-00430 Cable,Storage,MiniSAS HD,QSFP,12G,2m
X66021A-R6-C 112-00430 Cable,Storage,MiniSAS HD,QSFP,12G,2m,-C
X66022A-R6 112-00431 Cable,Storage,MiniSAS HD,QSFP,12G,5m
X66022A-R6-C 112-00431 Cable,Storage,MiniSAS HD,QSFP,12G,5m,-C
X66030A 112-00435 Cable,12Gb,Mini SAS HD,0.5m
X66030A-C 112-00435 Cable,12Gb,Mini SAS HD,0.5m,-C
X66030A-K-N 112-00435 Cable,12Gb,Mini SAS HD,0.5m
X66030A-N 112-00435 Cable,12Gb,Mini SAS HD,0.5m
X66030A-N-C 112-00435 Cable,12Gb,Mini SAS HD,0.5m,-C
X66031A 112-00436 Cable,12Gb,Mini SAS HD,1m
X66031A-C 112-00436 Cable,12Gb,Mini SAS HD,1m,-C
X66031A-K-N 112-00436 Cable,12Gb,Mini SAS HD,1m
X66031A-N 112-00436 Cable,12Gb,Mini SAS HD,1m
X66031A-N-C 112-00436 Cable,12Gb,Mini SAS HD,1m,-C
X66032A 112-00437 Cable,12Gb,Mini SAS HD,2m
X66032A-C 112-00437 Cable,12Gb,Mini SAS HD,2m,-C
X66032A-K-N 112-00437 Cable,12Gb,Mini SAS HD,2m
X66032A-N 112-00437 Cable,12Gb,Mini SAS HD,2m
X66032A-N-C 112-00437 Cable,12Gb,Mini SAS HD,2m,-C
X66034A 112-00439 Cable,12Gb,Mini SAS HD,5m
X66034A-C 112-00439 Cable,12Gb,Mini SAS HD,5m,-C
X66034A-K-N 112-00439 Cable,12Gb,Mini SAS HD,5m
X66034A-N 112-00439 Cable,12Gb,Mini SAS HD,5m
X66034A-N-C 112-00439 Cable,12Gb,Mini SAS HD,5m,-C
X66040A 112-00449 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m
X66040A-C 112-00449 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m,-C
X66040A-K-N 112-00449 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m
X66040A-N 112-00449 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m
X66040A-N-C 112-00449 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,1m,-C
X66041A 112-00450 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m
X66041A-C 112-00450 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m,-C
X66041A-K-N 112-00450 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m
X66041A-N 112-00450 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m
X66041A-N-C 112-00450 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,2m,-C
X66042A 112-00451 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m
X66042A-C 112-00451 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m,-C
X66042A-K-N 112-00451 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m
X66042A-N 112-00451 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m
X66042A-N-C 112-00451 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,3m,-C
X66043A 112-00452 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m
X66043A-C 112-00452 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m,-C
X66043A-K-N 112-00452 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m
X66043A-N 112-00452 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m
X66043A-N-C 112-00452 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,5m,-C
X66044A 112-00453 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,15m
X66045A 112-00454 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,30m
X66046A 112-00455 Cable,12Gb,SAS Opt,AOC,Mini SAS HD,50m
X66047A 112-00456 Cable,12Gb,SAS Opt,Mini SAS HD to LC,5m
X66047A-C 112-00456 Cable,12Gb,SAS Opt,Mini SAS HD to LC,5m,-C
X66047A-N-C 112-00456 Cable,12Gb,SAS Opt,Mini SAS HD to LC,5m,-C
X66048A 112-00457 Cable,12Gb,SAS Opt,Mini SAS HD to LC,30m
X66048A-C 112-00457 Cable,12Gb,SAS Opt,Mini SAS HD to LC,30m,-C
X66048A-N-C 112-00457 Cable,12Gb,SAS Opt,Mini SAS HD to LC,30m,-C
X66120-3 112-00545 Cable,Direct Attach CU 40G QSFP/4x10G SFP,3m
X66120-3-C 112-00545 Cable,Dir. Attach CU 40G QSFP/4x10G SFP,3m,-C
X66120-3-N-C 112-00545 Cable,Dir Attach CU 40G QSFP/4x10G SFP,3m,-C
X66120-5 112-00546 Cable,Direct Attach CU 40G QSFP/4x10G SFP,5m
X66120-5-C 112-00546 Cable,Dir. Attach CU 40G QSFP/4x10G SFP,5m,-C
X66120-5-N-C 112-00546 Cable,Dir Attach CU 40G QSFP/4x10G SFP,5m,-C
X66205-30 112-00261 Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m
X66205-30-C 112-00261 Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m,-C
X66205-30-N-C 112-00261 Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m,-C
X66205-5 112-00260 Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m
X66205-5-C 112-00260 Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m,-C
X66205-5-N-C 112-00260 Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m,-C
X66250-15 112-00346 Cable,LC-LC,OM4,15m
X66250-15-C 112-00346 Cable,LC-LC,OM4,15m,-C
X66250-15-N-C 112-00346 Cable,LC-LC,OM4,15m,-C
X66250-2 112-00342 Cable,LC-LC,OM4,2m
X66250-2-C 112-00342 Cable,LC-LC,OM4,2m,-C
X66250-2-N-C 112-00342 Cable,LC-LC,OM4,2m,-C
X66250-30 112-00347 Cable,LC-LC,OM4,30m
X66250-30-C 112-00347 Cable,LC-LC,OM4,30m,-C
X66250-30-N-C 112-00347 Cable,LC-LC,OM4,30m,-C
X66250-5 112-00344 Cable,LC-LC,OM4,5m
X66250-5-C 112-00344 Cable,LC-LC,OM4,5m,-C
X66250-5-N-C 112-00344 Cable,LC-LC,OM4,5m,-C
Disk Drive Blank-Filler
X5054-R6 108-00224 BLANK,DSK DRV FILLER,DS2246,R6
Drive
X302A-R5 108-00268 Disk Drive,1.0TB 7.2k,DS424x,FAS2240-4
X306A-R5 108-00270 Disk Drive,2.0TB 7.2k,DS424x,2554/2240-4
X308A-R5 108-00277 Disk Drive,3.0TB 7.2K,DS424x,2554/2240-4
X309A-R6 [1] 108-00301 DSK DRV,3TB 7.2k,NSE,DS424x,FAS2220/2240-4
X315A-R6 [1] 108-00368 DSK DRV,4TB 7.2k,NSE,DS424x,2554/2220/2240-4
X316A-R6 108-00389 Disk Drive,6TB 7.2k,DS4246,FAS2554
X317A [1] 108-00399 DSK DRV,6TB,7.2K,12G,NSE,DS212C
X318A-R6 108-00455 DSK DRV,8TB,7.2K,12G,DS212C
X319A 108-00687 SSD,7.6TB,12G,DS224C
X322A [1] 108-00551 DSK DRV,10TB,7.2K,12G,NSE,DS212C
X336A-R6 108-00427 DSK DRV,4TB,7.2K,12G,DS212C
X339A 108-00426 DSK DRV,2TB,7.2K,12Gb,DS212C,FAS2620
X341A-R6 108-00430 DSK DRV,900GB,10K,12G,DS224C
X342A-R6 108-00432 DSK DRV,1.2TB,10K,12G,DS224C
X343A-R6 108-00433 DSK DRV,1.8TB,10K,12G,DS224C
X356A-R6 108-00468 SSD,3.8TB,DS2246,FAS2552
X357A 108-00572 SSD,3.8TB,12G,DS224C,W/MSW
X358A [1] 108-00575 SSD,3.8TB,12G,NSE,DS224C
X363A-R6 108-00467 SSD,3.8TB,FAS2520/2554
X364A 108-00650 SSD,3.8TB,DS212C,FAS2620,w/MSW
X365A-R6 [1] 108-00477 SSD,1.6TB,NSE,DS2246,FAS2552
X366A-R6 [1] 108-00470 SSD,1.6TB,NSE,DS4246,FAS2554
X371A 108-00546 SSD,960GB,12G,DS224C,W/MSW
X374A 108-00573 SSD,960GB,12G,DS212C,W/MSW
X375A 108-00590 DSK DRV,4TB,7.2K,12G,DS460C
X376A 108-00591 DSK DRV,8TB,7.2K,12G,DS460C
X377A 108-00592 DSK DRV,10TB,7.2K,12G,DS460C
X378A [1] 108-00597 DSK DRV,10TB,7.2K,12G,NSE,DS460C
X379A 108-00598 SSD,960GB,12G,DS460C,W/MSW
X380A 108-00549 DSK DRV,10TB,7.2K,12G,DS212C
X386A [1] 108-00806 SSD,960GB,12G,NSE,DS224C
X387A 108-00886 DSK DRV,16TB,7.2K,12G,DS460C
X388A 108-00885 DSK DRV,16TB,7.2K,12G,DS212C
X416A-R5 [1] 108-00223 Disk Drive,600GB 10k,NSE,DS224x,FAS2240-2
X417A-R6 [1] 108-00246 DSK DRV,900GB,10K,NSE,DS2246,2552/2240-2
X421A-R5 108-00220 Disk Drive,450GB 10k,DS224x,FAS2240-2
X422A-R5 108-00221 Disk Drive,600GB 10k,DS224x,2552/2240-2
X423A-R5 108-00222 DSK DRV,900GB,10K,DS2246,2552/2240-2,R5
X425A-R6 108-00321 DSK DRV,1.2TB,10K,DS2246,2552/2240-2
X426A-R6 108-00424 DSK DRV,1.8TB,10K,DS2246,2552/2240-2
X427A [1] 108-00476 DSK DRV,1.8TB,10k,NSE,DS2246,FAS2552
X427B-R6 [1] 108-00438 DSK DRV,1.8TB,10K,12G,NSE,DS224C
X438A-R6 108-00369 SSD,400GB,DS224x,FAS2552/2240-2
X439A-R6 108-00372 SSD,1.6TB,DS224x,FAS2552/2240-2
X440A-R6 [1] 108-00374 SSD,800GB,NSE,DS224x,FAS2240-2,FAS2552
X440B-R6 [1] 108-00460 SSD,800GB,12G,NSE,DS224C
X441A-R5 108-00278 Solid State Drive,100GB,DS424x
X442A-R5 [2] 108-00249 Solid State Drive,100GB,3Gb,DS4243
X446B-R6 108-00323 SSD,200GB,B,DS224x,FAS2240-2,FAS2552
X447A-R6 108-00260 SSD,800GB,DS224x,FAS2552/2240-2
X448A-R6 108-00253 SSD,200GB,DS4246,FAS2554/2240-4/2220
X449A-R6 108-00319 SSD,800GB,DS4246,FAS2554/2240-4/2220
X477A-R6 108-00315 DSK DRV,4TB 7.2k,DS4246,2554/2220/2240-4
X488A-R5 108-00298 Disk Drive,900GB 10K,2520/2220
X489A-R6 108-00322 Disk Drive,1.2TB 10K,2520/2220
X490A-R6 108-00425 Disk Drive,1.8TB 10K,FAS2520
X575A-R6 108-00370 SSD,400GB,DS424x,FAS2554/2240-4/2220
X576A-R6 108-00373 SSD,1.6TB,DS424x,FAS2554/2240-4/2220
X577A-R6 [1] 108-00375 SSD,800GB,NSE,DS4246,FAS2554
X670A 108-00530 SSD,15.3TB,12G,DS224C
Memory Module
X3222A 107-00172 SODIMM,16GB,ECC,FAS2650
X3311A 111-03066 SUB ASSY,NVME,FLASH,1.0TB
Power Cord
X-50617-00 Jumper Crd,In-Cab,2m,C20-C13,E-Series
X-50617-00-0E-C Jumper Crd,In-Cab,2m,C20-C13,E-Series,0E,-C
X1558A-R6 Jumper Crd,In-Cab,48-IN,C13-C14
X1558A-R6-C Jumper Crd,In-Cab,48-IN,C13-C14-C
X800-42U-35 Jumper Crd,In-Cab,C13-C14,35-inch
X800-42U-35-C Jumper Crd,In-Cab,C13-C14,35-inch,-C
X800-42U-35-K-N Jumper Crd,In-Cab,C13-C14,35-inch
X800-42U-35-N Power Cable,In-Cabinet,C13-C14,35-inch
X800-42U-43 Jumper Crd,In-Cab,C13-C14,43-inch
X800-42U-43-C Jumper Crd,In-Cab,C13-C14,43-inch,-C
X800-42U-43-K-N Jumper Crd,In-Cab,C13-C14,43-inch
X800-42U-43-N Power Cable,In-Cabinet,C13-C14,43-inch
X800-42U-64 Jumper Crd,In-Cab,C13-C14,64-inch
X800-42U-64-C Jumper Crd,In-Cab,C13-C14,64-inch,-C
X800-42U-64-K-N Jumper Crd,In-Cab,C13-C14,64-inch
X800-42U-64-N Power Cable,In-Cabinet,C13-C14,64-inch
X800-42U-R6 Jumper Crd,In-Cab,C13-C14
X800-42U-R6-C Jumper Crd,In-Cab,C13-C14,-C
X800B-R6 Power Cable,Continental Europe,R6
X800B-R6-C Power Cable,Continental Europe,-C,R6
X800C-R6 Power Cable,UK and Ireland,R6
X800C-R6-C Power Cable,UK and Ireland,-C,R6
X800D-R6 Power Cable,Japan,R6
X800D-R6-C Power Cable,Japan,-C,R6
X800E-R6 Power Cable,North America,R6
X800E-R6-C Power Cable,North America,-C,R6
X800F-R6 Power Cable,Australia/New Zealand,R6
X800F-R6-C Power Cable,Australia/New Zealand,-C,R6
X800G-R6 Power Cable,Switzerland,R6
X800G-R6-C Power Cable,Switzerland,-C,R6
X800H-R6 Power Cable,Argentina,R6
X800H-R6-C Power Cable,Argentina,-C,R6
X800I-R6 Power Cable,China,R6
X800I-R6-C Power Cable,China,-C,R6
X800J-R6 Power Cable,Denmark,R6
X800J-R6-C Power Cable,Denmark,-C,R6
X800K-R6 Power Cable,India,South Africa,R6
X800K-R6-C Power Cable,India,South Africa,-C,R6
X800L-R6 Power Cable,Israel,R6
X800L-R6-C Power Cable,Israel,-C,R6
X800M-R6 Power Cable,Italy,R6
X800M-R6-C Power Cable,Italy,-C,R6
X800N POWER CABLE,INDIA BIS
X800N-C Power Cable,India BIS,-C
X800P-R6 Power Cable,North America,250V,R6
X800P-R6-C Power Cable,North America,250V,-C,R6
X800T-R6 Power Cable,Taiwan,BSMI,R6
X800T-R6-C Power Cable,Taiwan,BSMI,-C,R6
X800VB-R6 Power Cable,Brazil,IEC-60906-1-Plug
X800W-R6 Power Cable,Taiwan,250V,BSMI,R6
X800W-R6-C Power Cable,Taiwan,250V,BSMI,-C
X800Y-R6 Power Cable,Japan,250V/15A
X800Y-R6-C Power Cable,Japan,250V/15A,-C
Power Supply Unit
X5726A 114-00148 PSU,913W
Processor Controller Module (PCM)
X3218A 111-03965 Controller,No MEM,CNA,C190,FAS2700
X3218B 111-05221 Controller,No MEM,CNA2,C190,FAS2700
X3219A 111-04043 Controller,No MEM,RJ45,FAS2700
PSU
X5726A 114-00148 PSU,913W
Transceiver
X6567-R6 332-00378 SFP Optical 1GB Shortwave Multimode
X6567-R6-C 332-00378 SFP Optical 1GB Shortwave Multimode,-C
X6567-R6-N-C 332-00378 SFP Optical 1GB Shortwave Multimode,-C
X6568-R6 332-00374 SFP Copper 1GB RJ-45
X6568-R6-C 332-00374 SFP Copper 1GB RJ-45,-C
X6568-R6-N-C 332-00374 SFP Copper 1GB RJ-45,-C
X6588-R6 332-00278R6 SFP+Optical 8Gb Shortwave
X6588-R6-C 332-00278R6 SFP+Optical 8Gb Shortwave,-C
X6588-R6-N-C 332-00278R6 SFP+Optical 8Gb Shortwave,-C
X6589-N-C 332-00279R6 SFP+Optical 10Gb Shortwave,-C
X6589-R6 332-00279R6 SFP+Optical 10Gb Shortwave
X6589-R6-C 332-00279R6 SFP+ Optical 10Gb Shortwave,-C
X6596-R6 332-00331 SFP+ FC Optical 16Gb
X6596-R6-C 332-00331 SFP+ FC Optical 16Gb,-C
X6596-R6-N-C 332-00331 SFP+ FC Optical 16Gb,-C
X6599A-N-C 332-00363 SFP+ Optical 10Gb Shortwave,-C
X6599A-R6 332-00363 SFP+ Optical 10Gb Shortwave
X6599A-R6-C 332-00363 SFP+ Optical 10Gb Shortwave,-C
Footnote:
[1] Mixing NSE drives or shelves with any other type of encrypting or non-encrypting drives or shelves across a stand-alone platform or high-availability (HA) pair is not supported.
[2] This drive does not support the sanitization feature.

Supported Firmware Matrix - FAS2750 2-port UTA2 Single Chassis HA Pair

Major OS Version OS Version Firmeware
BIOS
ONTAP 9.11.1 9.11.1 11.15*
ONTAP 9.11.1 9.11.1RC1 11.16, 11.15*
ONTAP 9.10.1 9.10.1P5-P6 11.16, 11.15*
ONTAP 9.10.1 9.10.1P3-P4, 9.10.1P2, 9.10.1P1 11.16, 11.15, 11.13*
ONTAP 9.10.1 9.10.1, 9.10.1RC1 11.16, 11.15, 11.13, 11.11*
ONTAP 9.9.1 9.9.1P10 11.16, 11.15*
ONTAP 9.9.1 9.9.1P8-P9, 9.9.1P7 11.16, 11.15, 11.13*
ONTAP 9.9.1 9.9.1P4-P6, 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 11.16, 11.15, 11.13, 11.11*
ONTAP 9.8 9.8P13 11.16, 11.15*
ONTAP 9.8 9.8P11-P12 11.16, 11.15, 11.13*
ONTAP 9.8 9.8P10, 9.8P9, 9.8P8, 9.8P7, 9.8P6, 9.8P5, 9.8P4 11.16, 11.15, 11.13, 11.11*
ONTAP 9.8 9.8P3, 9.8P2, 9.8P1, 9.8, 9.8RC1 11.16, 11.15, 11.13, 11.11, 11.9*
ONTAP 9.7 9.7P19, 9.7P17-P18, 9.7P16, 9.7P15, 9.7P14 11.16, 11.15, 11.13, 11.11*
ONTAP 9.7 9.7P13, 9.7P12, 9.7P11, 9.7P10, 9.7P9, 9.7P8 11.16, 11.15, 11.13, 11.11, 11.9*
ONTAP 9.7 9.7P7, 9.7P6, 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7*
ONTAP 9.6 9.6P18, 9.6P17, 9.6P16, 9.6P15 11.16, 11.15, 11.13, 11.11*
ONTAP 9.6 9.6P13-P14, 9.6P12 11.16, 11.15, 11.13, 11.11, 11.9*
ONTAP 9.6 9.6P10-P11 11.16, 11.15, 11.13, 11.11, 11.9, 11.7*
ONTAP 9.6 9.6P9, 9.6P7-P8, 9.6P5-P6, 9.6P4, 9.6P3 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5*
ONTAP 9.6 9.6P2, 9.6, 9.6P1, 9.6RC2, 9.6RC1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5*
ONTAP 9.5 9.5P19, 9.5P18 11.16, 11.15, 11.13, 11.11*
ONTAP 9.5 9.5P17, 9.5P16, 9.5P15 11.16, 11.15, 11.13, 11.11, 11.9*
ONTAP 9.5 9.5P14 11.16, 11.15, 11.13, 11.11, 11.9, 11.7*
ONTAP 9.5 9.5P13, 9.5P12, 9.5P10-P11, 9.5P9, 9.5P8, 9.5P7, 9.5P6, 9.5P5, 9.5P4, 9.5P2-P3, 9.5P1, 9.5, 9.5RC1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4*
ONTAP 9.4 9.4P8, 9.4P7, 9.4P6, 9.4P5, 9.4P4, 9.4P3, 9.4P2, 9.4P1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4, 11.2.1*
ONTAP 9.4 9.4, 9.4RC1 11.16, 11.15, 11.13, 11.11, 11.9, 11.7, 11.5, 11.4, 11.2.1, 11.2*
BMC
ONTAP 9.11.1 9.11.1, 9.11.1RC1 11.8*
ONTAP 9.10.1 9.10.1P5-P6 11.8*
ONTAP 9.10.1 9.10.1P3-P4, 9.10.1P2, 9.10.1P1, 9.10.1, 9.10.1RC1 11.8, 11.7*
ONTAP 9.9.1 9.9.1P10, 9.9.1P8-P9, 9.9.1P7, 9.9.1P4-P6 11.8, 11.7*
ONTAP 9.9.1 9.9.1P3, 9.9.1P2, 9.9.1P1, 9.9.1, 9.9.1RC1 11.8, 11.7, 11.6*
ONTAP 9.8 9.8P13 11.8*
ONTAP 9.8 9.8P11-P12, 9.8P10, 9.8P9, 9.8P8 11.8, 11.7*
ONTAP 9.8 9.8P7, 9.8P6, 9.8P5, 9.8P4, 9.8P3 11.8, 11.7, 11.6*
ONTAP 9.8 9.8P2, 9.8P1 11.8, 11.7, 11.6, 11.5P1*
ONTAP 9.8 9.8, 9.8RC1 11.8, 11.7, 11.6, 11.5P1, 11.5*
ONTAP 9.7 9.7P19, 9.7P17-P18 11.8, 11.7*
ONTAP 9.7 9.7P16, 9.7P15, 9.7P14, 9.7P13 11.8, 11.7, 11.6*
ONTAP 9.7 9.7P12, 9.7P11 11.8, 11.7, 11.6, 11.5P1*
ONTAP 9.7 9.7P10, 9.7P9, 9.7P8, 9.7P7, 9.7P6 11.8, 11.7, 11.6, 11.5P1, 11.5*
ONTAP 9.7 9.7P5, 9.7P4, 9.7P3, 9.7P2, 9.7P1, 9.7, 9.7RC1 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4*
ONTAP 9.6 9.6P18, 9.6P17 11.8, 11.7*
ONTAP 9.6 9.6P16, 9.6P15 11.8, 11.7, 11.6*
ONTAP 9.6 9.6P13-P14 11.8, 11.7, 11.6, 11.5P1*
ONTAP 9.6 9.6P12, 9.6P10-P11 11.8, 11.7, 11.6, 11.5P1, 11.5*
ONTAP 9.6 9.6P9, 9.6P7-P8, 9.6P5-P6 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4*
ONTAP 9.6 9.6P4, 9.6P3 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2*
ONTAP 9.6 9.6P2 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1*
ONTAP 9.6 9.6, 9.6P1, 9.6RC2, 9.6RC1 11.8, 11.7, 11.6, 11.5P1, 11.5*, 11.4, 11.3P2, 11.3P1*
ONTAP 9.5 9.5P19 11.8, 11.7*
ONTAP 9.5 9.5P18 11.8, 11.7, 11.6*
ONTAP 9.5 9.5P17, 9.5P16 11.8, 11.7, 11.6, 11.5P1*
ONTAP 9.5 9.5P15, 9.5P14 11.8, 11.7, 11.6, 11.5P1, 11.5*
ONTAP 9.5 9.5P13, 9.5P12, 9.5P10-P11 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4*
ONTAP 9.5 9.5P9, 9.5P8, 9.5P7 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2*
ONTAP 9.5 9.5P6 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1*
ONTAP 9.5 9.5P5, 9.5P4, 9.5P2-P3, 9.5P1, 9.5, 9.5RC1 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.2*
ONTAP 9.4 9.4P8 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1*
ONTAP 9.4 9.4P7, 9.4P6, 9.4P5, 9.4P4, 9.4P3 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.1P3*
ONTAP 9.4 9.4P2 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.1P3, 11.1P2*
ONTAP 9.4 9.4P1, 9.4, 9.4RC1 11.8, 11.7, 11.6, 11.5P1, 11.5, 11.4, 11.3P2, 11.3P1, 11.3, 11.1P3, 11.1P2, 11.1*
Footnote:
[1]* Indicates that firmware is bundled with Storage OS Version

Product Certificates - FAS2750 2-port UTA2 Single Chassis HA Pair

Certificate Name Geo / Region / Country Associated Products
Battery Pack safety reports
Lithium Battery Safety Doc-Section II/Section IB Shipments,Inventus Power Product Model#271-00045AWB Global Platforms : AFF A220, AFF A320, AFF A400, AFF A700s, AFF A800, AFF C190, FAS2620, FAS2650, FAS2720, FAS2750, FAS8300, FAS8700
EMI and Safety certificates
Declaraion of Similarity NAJ-1502 Global Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 G-K-U-SoR Gabon,Kenya,SaudiArabia,Uganda Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 (FXN Taiwan) BIS BIS - India Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 (Jabil Mexico) BIS BIS - India Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 (Jabil Singapore) BIS BIS - India Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 60950-CB CB - International Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 62368-CB CB - International Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 ACMA ACMA - Australia, New Zealand Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 BSMI BSMI - Taiwan Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 CSA CSA - United States, Canada Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 DoC CE CE - European Union DoC Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 EAC EAC - Armenia, Belarus, Kazakhstan, Kyrgyzstan, Russia Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 IRAM IRAM - Argentina Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 KC KC - South Korea Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 Morocco Morocco Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 NOM NOM - Mexico Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 NRCS NRCS - South Africa (Safety) Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 SONCAP SONCAP - Nigeria Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 TBS TBS - Tanzania Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 UKRSep Global Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 VCCI VCCI - Japan Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 FCC FCC - United States Platforms : E2812, FAS2620, FAS2720, SG5712
NAJ-1502 UKCA DOC UKCA -United Kingdom Platforms : E2812, FAS2620, FAS2720, SG5712
PSU 80+ Platinum Certificates
DCJ9133-01 Energy Star Report Global Platforms : AFF A220, AFF C190, ASA AFF A220, FAS2720, FAS2750
TDPS-900AB A Energy Star Report Global Platforms : AFF A220, AFF C190, ASA AFF A220, FAS2720, FAS2750
Voluntary Product Accessibility Template
VPAT - NetApp Accessibility Conformance Report - NetApp FAS2720 Global Platforms : FAS2720

Size, Weight, Acoustic, Power FAS2750 2-port UTA2 Single Chassis HA Pair

Associated Part No. Configuration Rack Units Weight Sound Power Sound Pressure Line Voltage Actual (Min to Max) Amps Typical Amps Worst Watts Typical Watts Worst BTU / Hr Typical BTU / Hr Worst
Embedded Drive Config (Empty)
FAS2750-100-C FAS2750 2 PCM no drives 2 42.8 lb (19.4 kg) 6.9 Bels 51 dBA 100 (100 to 120) 2.72 4.16 266 407 908 1390
FAS2750-100-C FAS2750 2 PCM no drives 2 42.8 lb (19.4 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.34 2.04 261 399 891 1362
Embedded Drive Config (Half)
FAS2750-101-C FAS2750 2 PCM 12x900GB HDD 2 50.5 lb (22.9 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.95 5.39 387 528 1321 1803
FAS2750-101-C FAS2750 2 PCM 12x900GB HDD 2 50.5 lb (22.9 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.94 2.65 380 518 1297 1768
FAS2750-103-C FAS2750 2 PCM 12x1.2TB HDD 2 50.5 lb (22.9 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.8 5.24 372 513 1270 1751
FAS2750-103-C FAS2750 2 PCM 12x1.2TB HDD 2 50.5 lb (22.9 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.87 2.57 365 503 1246 1717
FAS2750-105-C FAS2750 2 PCM 12x1.8TB HDD 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.76 5.2 368 509 1256 1738
FAS2750-105-C FAS2750 2 PCM 12x1.8TB HDD 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.85 2.55 361 499 1233 1704
FAS2750-105-C FAS2750 2 PCM 12x1.8TB HDD NSE 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.76 5.2 368 509 1256 1738
FAS2750-105-C FAS2750 2 PCM 12x1.8TB HDD NSE 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.85 2.55 361 499 1233 1704
FAS2750-107-C FAS2750 2 PCM 12x1.8TB HDD 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.76 5.2 368 509 1256 1738
FAS2750-107-C FAS2750 2 PCM 12x1.8TB HDD 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.85 2.55 361 499 1233 1704
FAS2750-107-C FAS2750 2 PCM 12x1.8TB HDD NSE 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.76 5.2 368 509 1256 1738
FAS2750-107-C FAS2750 2 PCM 12x1.8TB HDD NSE 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.85 2.55 361 499 1233 1704
FAS2750-109-C FAS2750 2 PCM 12x960GB SSD 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.24 4.67 317 457 1082 1560
FAS2750-109-C FAS2750 2 PCM 12x960GB SSD 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.59 2.29 311 448 1062 1529
FAS2750-111-C FAS2750 2 PCM 12x3.8TB SSD 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.21 4.64 314 454 1072 1550
FAS2750-111-C FAS2750 2 PCM 12x3.8TB SSD 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.58 2.28 308 445 1052 1519
FAS2750-111-C FAS2750 2 PCM 12x3.8TB SSD NSE 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.21 4.64 314 454 1072 1550
FAS2750-111-C FAS2750 2 PCM 12x3.8TB SSD NSE 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.58 2.28 308 445 1052 1519
FAS2750-113-C FAS2750 2 PCM 12x3.8TB SSD 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.21 4.64 314 454 1072 1550
FAS2750-113-C FAS2750 2 PCM 12x3.8TB SSD 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.58 2.28 308 445 1052 1519
FAS2750-113-C FAS2750 2 PCM 12x3.8TB SSD NSE 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.21 4.64 314 454 1072 1550
FAS2750-113-C FAS2750 2 PCM 12x3.8TB SSD NSE 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.58 2.28 308 445 1052 1519
FAS2750-115-C FAS2750 2 PCM 12x7.6TB 2 48.7 lb (22.1 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.32 4.75 325 465 1110 1587
FAS2750-115-C FAS2750 2 PCM 12x7.6TB 2 48.7 lb (22.1 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.63 2.33 319 456 1089 1557
FAS2750-117-C FAS2750 2 PCM 12x15.3TB SSD 2 48.7 lb (22.1 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.34 4.78 327 468 1117 1598
FAS2750-117-C FAS2750 2 PCM 12x15.3TB SSD 2 48.7 lb (22.1 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.64 2.35 321 459 1096 1567
FAS2750-127-C FAS2750 2 PCM 12x960GB SSD 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.24 4.67 317 457 1082 1560
FAS2750-127-C FAS2750 2 PCM 12x960GB SSD 2 51.8 lb (23.5 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.59 2.29 311 448 1062 1529
Embedded Drive Config (Full)
FAS2750-102-C FAS2750 2 PCM 24x900GB HDD 2 58.2 lb (26.4 kg) 6.9 Bels 51 dBA 100 (100 to 120) 5.19 6.62 508 648 1734 2212
FAS2750-102-C FAS2750 2 PCM 24x900GB HDD 2 58.2 lb (26.4 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.55 3.25 498 636 1700 2171
FAS2750-104-C FAS2750 2 PCM 24x1.2TB HDD 2 58.2 lb (26.4 kg) 6.9 Bels 51 dBA 100 (100 to 120) 4.87 6.31 477 618 1628 2110
FAS2750-104-C FAS2750 2 PCM 24x1.2TB HDD 2 58.2 lb (26.4 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.39 3.1 468 606 1598 2069
FAS2750-106-C FAS2750 2 PCM 24x1.8TB HDD 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 4.8 6.23 470 610 1605 2082
FAS2750-106-C FAS2750 2 PCM 24x1.8TB HDD 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.36 3.06 461 598 1574 2041
FAS2750-106-C FAS2750 2 PCM 24x1.8TB HDD NSE 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 4.8 6.23 470 610 1605 2082
FAS2750-106-C FAS2750 2 PCM 24x1.8TB HDD NSE 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.36 3.06 461 598 1574 2041
FAS2750-108-C FAS2750 2 PCM 24x1.8TB HDD 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 4.8 6.23 470 610 1605 2082
FAS2750-108-C FAS2750 2 PCM 24x1.8TB HDD 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.36 3.06 461 598 1574 2041
FAS2750-108-C FAS2750 2 PCM 24x1.8TB HDD NSE 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 4.8 6.23 470 610 1605 2082
FAS2750-108-C FAS2750 2 PCM 24x1.8TB HDD NSE 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.36 3.06 461 598 1574 2041
FAS2750-110-C FAS2750 2 PCM 24x960GB SSD 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.75 5.18 367 507 1253 1731
FAS2750-110-C FAS2750 2 PCM 24x960GB SSD 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.84 2.54 360 497 1229 1697
FAS2750-112-C FAS2750 2 PCM 24x3.8TB SSD 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.69 5.12 361 501 1233 1710
FAS2750-112-C FAS2750 2 PCM 24x3.8TB SSD 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.81 2.51 354 491 1209 1676
FAS2750-112-C FAS2750 2 PCM 24x3.8TB SSD NSE 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.69 5.12 361 501 1233 1710
FAS2750-112-C FAS2750 2 PCM 24x3.8TB SSD NSE 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.81 2.51 354 491 1209 1676
FAS2750-114-C FAS2750 2 PCM 24x3.8TB SSD 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.69 5.12 361 501 1233 1710
FAS2750-114-C FAS2750 2 PCM 24x3.8TB SSD 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.81 2.51 354 491 1209 1676
FAS2750-114-C FAS2750 2 PCM 24x3.8TB SSD NSE 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.69 5.12 361 501 1233 1710
FAS2750-114-C FAS2750 2 PCM 24x3.8TB SSD NSE 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.81 2.51 354 491 1209 1676
FAS2750-116-C FAS2750 2 PCM 24x7.6TB 2 54.5 lb (24.7 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.91 5.35 383 524 1308 1789
FAS2750-116-C FAS2750 2 PCM 24x7.6TB 2 54.5 lb (24.7 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.92 2.63 376 514 1284 1755
FAS2750-118-C FAS2750 2 PCM 24x15.3TB SSD 2 54.5 lb (24.7 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.95 5.39 387 528 1321 1803
FAS2750-118-C FAS2750 2 PCM 24x15.3TB SSD 2 54.5 lb (24.7 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.94 2.65 380 518 1297 1768
FAS2750-128-C FAS2750 2 PCM 24x960GB SSD 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 3.75 5.18 367 507 1253 1731
FAS2750-128-C FAS2750 2 PCM 24x960GB SSD 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 1.84 2.54 360 497 1229 1697
Embedded Drive Config (Mixed)
FAS2750-119-C FAS2750 2 PCM 4x960GB, 20x900GB 2 58.6 lb (26.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 4.94 6.38 484 625 1652 2134
FAS2750-119-C FAS2750 2 PCM 4x960GB, 20x900GB 2 58.6 lb (26.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.43 3.13 475 613 1622 2093
FAS2750-120-C FAS2750 2 PCM 4x960GB, 20x1.2TB 2 58.6 lb (26.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 4.69 6.13 459 600 1567 2048
FAS2750-120-C FAS2750 2 PCM 4x960GB, 20x1.2TB 2 58.6 lb (26.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.3 3 450 588 1536 2007
FAS2750-121-C FAS2750 2 PCM 4x960GB, 20x1.8TB 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 4.62 6.06 452 593 1543 2024
FAS2750-121-C FAS2750 2 PCM 4x960GB, 20x1.8TB 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.27 2.97 443 582 1512 1987
FAS2750-122-C FAS2750 2 PCM 4x3.8TB, 20x900GB 2 58.6 lb (26.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 4.93 6.37 483 624 1649 2130
FAS2750-122-C FAS2750 2 PCM 4x3.8TB, 20x900GB 2 58.6 lb (26.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.42 3.13 474 612 1618 2089
FAS2750-123-C FAS2750 2 PCM 4x3.8TB, 20x1.2TB 2 58.6 lb (26.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 4.68 6.12 458 599 1564 2045
FAS2750-123-C FAS2750 2 PCM 4x3.8TB, 20x1.2TB 2 58.6 lb (26.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.3 3 449 588 1533 2007
FAS2750-124-C FAS2750 2 PCM 4x3.8TB NSE, 20x1.8TB NSE 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 4.61 6.05 451 592 1540 2021
FAS2750-124-C FAS2750 2 PCM 4x3.8TB NSE, 20x1.8TB NSE 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.26 2.97 442 581 1509 1983
FAS2750-124-C FAS2750 2 PCM 4x3.8TB, 20x1.8TB 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 4.61 6.05 451 592 1540 2021
FAS2750-124-C FAS2750 2 PCM 4x3.8TB, 20x1.8TB 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.26 2.97 442 581 1509 1983
FAS2750-125-C FAS2750 2 PCM 4x3.8TB NSE, 20x1.8TB NSE 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 4.61 6.05 451 592 1540 2021
FAS2750-125-C FAS2750 2 PCM 4x3.8TB NSE, 20x1.8TB NSE 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.26 2.97 442 581 1509 1983
FAS2750-125-C FAS2750 2 PCM 4x3.8TB, 20x1.8TB 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 4.61 6.05 451 592 1540 2021
FAS2750-125-C FAS2750 2 PCM 4x3.8TB, 20x1.8TB 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.26 2.97 442 581 1509 1983
FAS2750-126-C FAS2750 2 PCM 4x960GB, 20x1.8TB 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 100 (100 to 120) 4.62 6.06 452 593 1543 2024
FAS2750-126-C FAS2750 2 PCM 4x960GB, 20x1.8TB 2 60.8 lb (27.6 kg) 6.9 Bels 51 dBA 200 (200 to 240) 2.27 2.97 443 582 1512 1987

 

Shipping Information

Express Computer Systems can ship to virtually any address in the world and provides you with the best shipping rates possible. Cost of shipping varies depending on what service you require, your destination and size of the shipment. Shipping costs will be calculated separately from your order and billed to you post purchase. In the notes section of your order please provide us with your preferred shipping method and we will get back to you.

Custom configured orders ship within 2 business days after all required products are in stock.

Please allow 3 business days for products that are not in stock to arrive to our facility in Irvine, California.

Domestic Shipments
  • Standard Ground
    • Shipping time: 2-7 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-10 business days
    • Excludes weekends, holidays or weather delays.
  • 3 Business Days
    • Shipping time: 3 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 3-6 business days
    • Excludes weekends, holidays or weather delays.
  • 2 Business Days
    • Shipping time: 2 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-5 business days
    • Excludes weekends, holidays or weather delays.
  • Overnight / Next Business Day
    • Shipping time: 1 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 1-4 business days
    • Excludes weekends, holidays or weather delays.
International Shipments
  • International Economy
    • Shipping time: 4-6 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 5-9 business days
    • Excludes weekends, holidays or weather delays.
  • International Priority
    • Shipping time: 1-3 business days
    • Order processing time: 0-3 business days
    • Delivery time after order is placed: 2-6 business days
    • Excludes weekends, holidays or weather delays.

For more information on shipping view our Shipping Information page or send us a message

ECS Warranty Information

Express Computer Systems (ECS) provides a 1 year parts warranty against defects in material or workmanship that will affect the products functionality. All refurbished items are tested prior to shipping to guarantee up-time upon arrival. If you are having issues with an item we provided please Contact Us and we will do our best to assist you.

What does our ECS warranty cover?
We offer 1 year warranty as standard and additional years can be added to fit your needs. Please reach out to a sales associate via the Contact Us page or live chat for more information on extended coverage options. During the coverage period if your product fails we will offer a Next Business Day replacement. If we are unable to replace the product we will refund its original selling price. Shipping costs and tax are not refundable. Express Computer Systems retains the right to decide whether the goods will be replaced or refunded.

What is not covered by our warranty?
Our warranty does not cover any problem caused by the following conditions:

  1. accidents; misuse; carelessness; electrostatic discharge; shock; temperature or humidity beyond the specifications of the product; improper installation; operation; modification;
  2. any improper use that contravenes the instructions in the user manual;
  3. problems caused by other equipment. Our warranty is void if the product is returned with damaged, removed, counterfeit labels, or any modifications (including any component or external cover removal). Our warranties do not cover data loss or damages to any other equipment. In addition, our warranties do not cover incidental damages, consequential damages, or costs related to data recovery, removal, and installation.

Important notes:

  • Please ask for additional warranty/coverage that you may require in addition to the standard 1 ECS warranty prior to final purchase. Requesting additional warranty after your purchase can be denied.
  • FREE technical support is provided on purchased items via phone, email, or live chat.

About Express Computer Systems

Express Computer Systems is committed to transforming our customers’ IT infrastructure with high quality products at affordable costs. Our sales reps and customer support engineers understand our customers rely heavily on advanced technology to run their business but need to do so without breaking the bank.

We specialize in building custom server configurations, custom storage solutions, networking solutions, and components from top manufacturers including HPE, Dell, Cisco, NetApp, Dell EMC, HPE Nimble and many others.

Subscribe