Base Standard Capabilities
Product features
Feature | Description | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Processor (One of the following depending on the model) | E5-2600 v2 series Processors
E5-2600 series Processors
| |||||||||||||||||||||
Cache memory (One of the following depending on the model) |
| |||||||||||||||||||||
Chipset |
| |||||||||||||||||||||
Upgradeability |
| |||||||||||||||||||||
On-system management chipset | HP iLO (Firmware: HP iLO 4) | |||||||||||||||||||||
Memory protection |
| |||||||||||||||||||||
Memory (One of the following depending on the model) |
| |||||||||||||||||||||
Network controller (One of the following depending on the model) | HP 1Gb Ethernet 4-port 331i adapter | |||||||||||||||||||||
Storage controller (One of the following depending on the model) |
| |||||||||||||||||||||
Internal storage devices |
| |||||||||||||||||||||
Maximum internal storage |
| |||||||||||||||||||||
Interfaces |
| |||||||||||||||||||||
Industry standard compliance |
| |||||||||||||||||||||
Graphics | Integrated Matrox G200 video standard
HP iLO 4 On System Management Memory
| |||||||||||||||||||||
System fans (One of the following depending on the model) |
| |||||||||||||||||||||
Form factor | Tower or Rack (5U) |
More Specs
Physical specifications
Feature | Description |
---|---|
Dimensions (H x W x D) (with feet/bezel) |
|
Weight (approximate) |
|
Electrical specifications
Feature | Description |
---|---|
Rated line voltage | 100 to 240 V ac |
Rated input current | 7.1 A (at 120 V ac) to 3.5 A (at 240 V ac) |
Rated input frequency | 50 to 60 Hz |
Rated input power | 852 W |
BTU rating (maximum) |
|
Rated steady-state power |
|
Maximum peak power |
|
Environmental specifications
Feature | Description |
---|---|
System inlet temperature (operating) | 10° to 35°C (50° to 95°F), at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). |
System inlet temperature (non-operating) | -30° to +60°C (-22° to +140°F). Maximum rate of change is 20°C/hr (36°F/hr). |
Relative humidity (operating) | 10% to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing |
Relative humidity (non-operating) | 5% to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing |
Altitude (operating) | 3048 m (10,000 ft) |
Altitude (non-operating) | 9144 m (30,000 ft) |
Acoustic noise | Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
|