Base Standard Capabilities
Product features
Feature | Description |
---|---|
Processor(One of the following depending on model) | E5-4600 v2 series Processors
E5-4600 series Processors
|
Cache memory(One of the following depending on model) |
|
Chipset 1 | Intel C600 Series Chipset |
Upgradeability | Upgradeable to four (4) processors |
On System Management Chipset | HPE iLO (Firmware: HP iLO 4)2 |
Memory protection |
|
Memory(One of the following depending on model)3 |
|
Network controller 4 | Two (2) HP FlexibleLOM connectors for one or two dual-port FlexibleLOMs |
Expansion slots |
|
Storage controller (All models) |
|
Maximum internal storage 6 |
|
Interfaces 7 |
|
Graphics |
|
Form factor | HP ProLiant BL660c Gen8 is a single-wide, full-height server blade that plugs into the HP BladeSystem c3000 and c7000 enclosures |
Industry standard compliance |
|
NOTE: 2. Click here for more information on iLO . 3. HP memory from previous generation servers are not qualified or warranted with this server. HP SmartMemory is required to realize the memory performance improvements and enhanced functionality listed in this document for Gen8. Click here for additional information on HP SmartMemory . LRDIMMs and RDIMMs are distinct memory technologies and cannot be mixed within a server.Depending on the memory configuration and processor model, the memory speed may run at 1600 MHz, 1333 MHz or 1066 MHz. 4. FlexibleLOM options include 10Gb FlexFabric, 10Gb Flex-10, and 10Gb Ethernet.FlexFabric capabilities require the use of an HP Virtual Connect FlexFabric module. The server supports one or two FlexibleLOMs, which must be identical. For Pre-configured Model configurations, two FlexibleLOMs are already included; no additional FLexibeLOMs are added.For a Factory Integrated Model configuration with one FlexibleLOM, it is added in the HP Networking section of "Step 2" in the Factory Integrated Models section. For a Factory Integrated Model configuration with two FlexibleLOMs, the second FlexibleLOM (although same technology) is a different part number. User must select the first FlexibleLOM in the "Step 2" HP Networking section and select the second FlexibleLOM in the "Step 4" HP Networking section. All FlexibleLOMs are dual port: one port is routed to interconnect module bay 1 and the other to bay 2. 5. The HP Smart Array P220i includes 512MB flash-backed write cache (FBWC) supporting RAID 0 and 1 on pre-configured models and is optional on factory integrated models.The HPE Smart Array P220i supports upgradeable firmware with recovery ROM. The HP Smart Array P220i supports two (2) small form factor (SFF) hot plug drive bays. 6. The ProLiant BL660c Gen8 server includes the new HP hot plug small form factor (SFF) SmartDrive carrier for enhanced management and reduced maintenance errors. HP drives from previous generation servers are not compatible with the ProLiant BL660c Gen8 drive bays.The mixing of standard SAS drives with SAS SSD drives is supported within the server, but limits the RAID configuration to two separate RAID 0 volumes. Mixing of other drives types is not supported. 7. The above options are for integrated hypervisor virtualization environments needing a low cost boot solution with the highest performance and reliability. |
Specs 1
Software overview
Feature | Description |
---|---|
Operating systems and virtualization software support for ProLiant servers 1 |
|
HP Insight management software |
|
High performance clusters |
|
NOTE: 1. For more information on HPE's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for server, visit the Support Matrix and the driver download page. Click here to access the support matrix . Click here to access the driver download page . |
Physical specifications
Specifications | Description |
---|---|
Dimensions (H x W x D) (with bezel) | 366.27 x 56.54 x 516.67 mm (14.42 x 2.23 x 20.34 in) |
Weight (approximate) |
|
Specs 2
Electrical specifications
Specifications | Description |
---|---|
HP BladeSystem c3000 Enclosure | |
Input requirements (per AC power supply) |
|
BTU rating |
|
Power supply output (per power supply) |
|
HP BladeSystem c7000 Enclosure | |
Input requirements (Single phase model) |
|
Input requirements (Three phase NA/JPN model) |
|
Input requirements (Three phase international model) |
|
Input requirements DC power |
|
Output specifications (per power supply) |
|
Specs 3
Environmental specifications
Specifications | Description |
---|---|
System inlet temperature |
|
Relative humidity (non-condensing) |
|
Altitude |
|
NOTE: 1. Measurement at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1,000 ft) above sea level to a maximum of 3,050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). 2. Maximum rate of change is 20°C/hr (36°F/hr). |