Please Upgrade Server
*This Configure to Order has not been created.
*You can still
Contact Us
for a quote on this server.
*Thank you.
The request has been sent.
Thank you.
Price as Configured:
$0
HPE BLC7000 CTO Blade Enclosure Taa-Compliant Platinum Enclosure With 2X Onboard Admin 6X Ps 10X Fans | 681844-B22
-PLEASE CONTACT FOR CUSTOM CONFIGURATIONS. DISK SHELVES, COMPLETE CONFIGURATIONS & TURN KEY SYSTEMS AVAILABLE.
-SPARE PARTS AVAILABLE FOR EACH MODEL. PLEASE ASK FOR PRICING ON SPARE DISK, CONTROLLERS, POWER SUPPLIES, NICs, HBAs, SFPs, Cables, etc.
The BladeSystem c7000 enclosure provides all the power, cooling, and I/O infrastructure needed to support modular server, interconnect, and storage components today and throughout the next several years.
- RoHS compliance
- 7Tb/s Midplane (40% increase), improved signal integrity; adds:
-
- 16Gb FC
- 4xFDR IB (>1 port/server)
- 16Gb FC
- 1Phase intelligent input module
- Location Discovery Services
- 2650W Platinum power supply options
- High voltage power solution options
The enclosure is 10U high and holds up to 16 server and/or storage blades plus optional redundant network and storage interconnect modules. It includes a shared 7.1 Tbps high-speed NonStop mid-plane for wire-once connectivity of server blades to network and shared storage. Power is delivered through a pooled-power backplane, and power input flexibility is provided with choices of single-phase AC input, 3-phase AC input, -48V DC input, and high voltage DC input.
Each c7000 enclosure is built with the following functions:
- Up to 16 half-height server blades, 8 full-height server blades, and/or 8 expansion blades per enclosure (not exceeding 16 total blades).
- Up to 4 redundant interconnect I/O fabrics (Ethernet, Fibre Channel, InfiniBand, iSCSI, SAS, etc.) supported simultaneously within the enclosure. • Choice of single-phase high-line AC, three-phase high-line AC, single-phase high voltage AC, -48V DC, or high voltage DC power options for flexibility in connecting to datacenter power.
- HPE Thermal Logic technology to minimize power consumption and reduce cooling.
- A minimum of four hot-plug HPE Active Cool 200 Fans. For additional capacity, redundancy, and improved power consumption and acoustics, Active Cool 200 Fan kits can be added for a maximum of 10 fans.
- Redundant hot-plug cooling, redundant hot-plug power supplies, redundant connections, redundant interconnect modules, and optional redundant BladeSystem Onboard Administrator management module.
Extending the foundation for Converged Infrastructure
- The HPE BladeSystem c7000 Enclosure goes beyond just Blade servers. It consolidates server, storage, networking and power management into a single solution that can be managed as a unified environment.
- With demanding workloads, the increased power supply wattage and mid-plane bandwidth aligned with Intelligent Infrastructure technologies such as Platinum Power Supplies, Intelligent Power Module, and Location Discovery Services have enhanced the foundation for converged infrastructure.
- HPE OneView combines server, storage, and networking with control of your data center environment into a single, integrated management platform architected to deliver lifecycle management for the complete Converged Infrastructure.
- With Onboard Administrator, iLO remote management, and HPE OneView you can manage your servers and take complete control regardless of the state of the server operating system.
HPE BladeSystem c7000 Base Knowledge .
The enclosures listed below include an Onboard Administrator with KVM and four (4) hot-plug Active Cool 200 Fans. The power module, power supply kits, power cables, interconnects, additional fans, etc. are added per the steps below.
The HPE c7000 is like the big brother to the HPE c3000. Both can handle the same HPE Blade server with the main difference being the amount each can support. The c3000 can handle up to 8 Blade Servers while the c7000 can handle up to 16 Blade Servers.
The c7000 enclosure is divided into 4 zones by the vertical support metalwork. Within each zone, a removable divider is used to support half-height devices. To install a full-height blade in any zone this divider must be removed. As a consequence, a zone can only contain either full-height server blades or half-height server blades.
An enclosure zone can only contain either full-height server blades or half-height server blades; mixing of the two form factors is not allowed except when connecting an expansion blade to a server partner blade.
NOTE: Insight Control is not supported with Gen10 server blades.
HPE BladeSystem c7000 Interconnect and Networking
The HPE c7000 can handle up to 8 Interconnects and 2 Onboard Administrators. The Interconnect bays 1 and 2 support the network (i.e. Ethernet capable) interconnects. These bays connect to the included network adapter ports in the server blades. Interconnect bays 3 and 4 must contain the same type of interconnect (network, SAN, SAS, etc) as they connect to the same mezzanine slot. Likewise for interconnect bays 5, 6, 7, and 8.
HPE BladeSystem c7000 Cooling
With a total of 10 fans this server can handle configurations with 4 or 6 fans. Ten fans are strongly recommended for maximum cooling efficiency and redundancy, reduced power consumption, and reduced noise. The enclosure supports a minimum of 4 Active Cool 200 Fans to a maximum of 10 Active Cool 200 Fans.
HPE BladeSystem c7000 PSU
Mixing of power supplies is not supported, except during hot swaps to different level or higher efficient power supplies.
Please Upgrade Server
*This Configure to Order has not been created.
*You can still
Contact Us
for a quote on this server.
*Thank you.
The request has been sent.
Thank you.
Price as Configured:
$0
Base Standard Capabilities
Product features
Feature | Description |
|---|---|
Functions |
|
Benefits |
|
Blade system onboard administrator management |
|
HPE blade systemc-Class c3000Enclosure | For users that need a smaller blade system, the HPE BladeSystem c-Class c3000 Enclosure is the perfect solution. Supporting up to 8 blades and 4 inter connects, the c3000 enclosure provides an ideal solution for small and medium businesses and remote sites. |
HPE ProLiant andintegrity serverblades |
|
HPE D2200sb storage blade |
|
HPE ultrium tape Blades1 |
|
Dynamic power capping |
|
Rack airflow requirements | Rack 10000 G2 series cabinets The increasing power of new High-Performance processor technology requires increased cooling efficiency for rack-mounted servers. The G2 10000 Series racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors. |
Factory express portfolio for servers and storage | HPE Factory express offers configuration, customization, integration and deployment services for HP servers and storage products. Users can choose how their factory solutions are built, tested, integrated, shipped and deployed. |
HPE simple configurator |
|
HPE power advisor |
|
Specs 1
Physical specifications
Specifications | Description | |
|---|---|---|
Dimensions (H x W x D): | 442 x 447.04 x 813 mm (17.4 x 17.5 x 32.0 in) | |
Enclosure weight |
| |
Power input module weight | 1.4 kg (3 lb) | |
Power supply weight | 2.7 kg (6 lb) | |
HPE Active cool 200 fan weight | 1.8 kg (4 lb) | |
Onboard administrator weight | 1.4 kg (3 lb) | |
Maximum enclosure weight |
| |
Option kits | Power supply option shipping dimensions | 223 x 219 x 892 mm (8.75 x 8.63 x 35.13 in) |
Weight | 3.85 kg (8.5 lb) | |
Fan option shipping dimensions | 223 x 248 x 403 mm (8.75 x 9.75 x 15.88 in) | |
Weight | 1.8 kg (4.0 lb) | |
BladeSystem onboard administrator option shipping dimensions | 63.5 x 251 x 343 mm (2.50 x 9.88 x 13.50 in) | |
Weight | 1.8 kg (4.0 lb) | |
Specs 2
Environmental specifications
Specifications | Description | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Operating temperature1 | 10° to 35° C (50° to 95° F) | ||||||||||||
Non-operating temperature | -30°C to 60°C (-22°F to 140°F) | ||||||||||||
Operating relative humidity1 | 10% to 90% non-condensing | ||||||||||||
Operating Non-operating humidity | 5% to 95% non-condensing | ||||||||||||
Acoustic noise2 | Listed are the declared A-Weighted sound power levels (LWAd) and declared averagebystander position A-Weighted sound pressure levels (LpAm) when the product isoPerating in a 23°C ambient environment. Noise emissions were measured inaccordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296(ECMA 109)
| ||||||||||||
NOTE: 1.Operating temperature has an altitude derating of 1°C (1.8°F) per 304.8 m (1,000 ft). No direct sunlight. Upper operating limit is 3,048 m (10,000 ft) or 70Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3 Kpa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage is 70 Kpa. 2. Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C (73.4°F) ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). | |||||||||||||
Specs 3
Power specifications
Specifications | Description | |
|---|---|---|
Single phase AC power input module | ||
Single phase AC intelligent power input module | Power connection1 | 6x IEC-320 C20 blue power connectors |
Rated input voltage | 200 to 220 V ac | |
Rated input frequency | 50 to 60 Hz | |
Number of power supplies supported |
| |
2250 W power supply | Maximum output (Per power supply): 2250 W | |
Maximum output (Total for six power supplies): 13,050 W | ||
Maximum input current (Per power supply)
Maximum input power (Per power supply): 2621 VA | ||
2400 W gold power supply | Maximum output (Per power supply): 2450 W | |
Maximum output (Total for six power supplies): 14,210 W | ||
Maximum input current (Per power supply)
| ||
Maximum input power (Per power supply): 2780 VA | ||
2400 W platinum power supply | Maximum output (Per power supply): 2450 W | |
Maximum output (Total for six power supplies): 14,210 W | ||
Maximum input current (Per power supply)
| ||
Maximum input power (Per power supply): 2640 VA | ||
2650 W platinum power supply | Maximum output (Per power supply): 2650 W | |
Maximum output (Total for six power supplies): 15,370 W | ||
Maximum input current (Per power supply)
| ||
Three phase AC NA/JPN power input module | Power connection | Two 3.05 m (10 ft) power cables with NEMA L15-30p connectors |
Rated input voltage |
| |
Rated input frequency | 50 to 60 Hz | |
Number of power supplies supported |
| |
2250 W power supply | Maximum output (Per power supply): 2250 W | |
Maximum output (Total for six power supplies): 13,050 W | ||
Maximum input current Per line cord
Maximum input power Per line cord: 7863 VA | ||
2400 W gold power supply | Maximum output (Per power supply): 2450 W | |
Maximum output (Total for six power supplies): 14,210W | ||
Maximum input current Per line cord
| ||
Maximum input power per line cord: 8352 VA | ||
2400 W platinum power supply | Maximum output (Per power supply): 2450 W | |
Maximum output (Total for six power supplies): 14,210 W | ||
Maximum input current per line cord
| ||
Maximum input power per line cord: 7920 VA | ||
2650 W platinum power supply | Maximum output (Per power supply): 2650 W | |
Maximum output (Total for six power supplies): 15,370 W | ||
Maximum input current per line cord
Maximum input power per line cord: 8640 VA | ||
Three phase AC international power input module | Power connection | Two 3.05 m (10 ft) power cables with IEC-309 220/380 V - 240/415 V, 5-Pin, 6h, 16 A connectors |
Rated input voltage |
| |
Rated input frequency | 50 to 60 Hz | |
Number of power supplies supported |
| |
2250 W power supply | Maximum output (Per power supply): 2250 W | |
Maximum output (Total for six power supplies): 13,050 W | ||
Maximum input current per line cord:
Maximum input power per line cord: 7854 VA | ||
2400 W gold power supply | Maximum output (Per power supply): 2450 W | |
Maximum output (Total for six power supplies): 14,210 W | ||
Maximum input current per line cord:
Maximum input power per line cord: 8316 VA | ||
2400 W platinum power supply | Maximum output (Per power supply): 2450 W | |
Maximum output (Total for six power supplies): 14,700 W | ||
Maximum input current per line cord:
Maximum input power per line cord: 8064 VA | ||
2650 W platinum power supply | Maximum output (Per power supply): 2650 W | |
Maximum output (Total for six power supplies): 15,370 W | ||
Maximum input current Per line cord:
Maximum input power Per line cord: 8646 VA | ||
-48 V dc power input module | Power connection |
|
Rated input voltage | 40 to 60 V dc | |
Number of power supplies supported |
| |
2250 W -48 V dc power supply | Maximum output (Per power supply): 2250 W | |
Maximum output (Total for six power supplies): 13,050 W | ||
Maximum input current (Per power supply): 75 A | ||
2650 W -48 V dc power supply | Maximum input power Per supply: 2700 W | |
Maximum output (Per power supply): 2650 W | ||
Maximum output (Total for six power supplies): 15,370 W | ||
Maximum input current (Per power supply): 73A | ||
Maximum input power per supply:2892 W | ||
High voltage power input module | Power connection | 6x APP Saf-D-Grid receptacle connectors3 |
Rated input voltage | 277 V ac, 380 V dc | |
Rated input frequency | 50 to 60 Hz (AC), N/A (DC) | |
Number of power supplies supported |
| |
2650 W universal power supply | Maximum output (Per power supply): 2650 W | |
Maximum output (Total for six power supplies) 15,370 W | ||
Maximum input current (Per power supply):
| ||
NOTE: 1.The blue power connectors indicate HPE Power Discovery Services capability. HPE Power discovery services are enabled when used with an Intelligent Power Distribution Unit (iPDU), iPDU cables, and a platinum power supply kit. One WW 250 W C19-C20 2.0 m power cable is included per power supply. iPDU power cables are ordered separately. 2. Rated 220 to 240 V ac line-to-neutral. The enclosure will not operate from higher line-to-line voltage with the WYE wall plug configuration. This power input module is configured to provide 220 to 240 V ac to the power supplies. 3. Power cables with APP Saf-D-Grid connectors are ordered separately. | ||