Storage Limits
Max # of Drives (Total) | Max # of Internal Drives | Max # of MSATA Drives | Max # of NL-SAS Drives | Max # of SAS Drives | Max # of SATA Drives | Max # of NVMe SSD Drives | Max # of SSD Drives | Max # of DS2126 Shelves | Max # of DS212C Shelves | Max # of DS2246 Shelves | Max # of DS224C Shelves | Max # of DS4243 Shelves | Max # of DS4246 Shelves | Max # of DS4486 Shelves | Max # of DS460C Shelves | Max # of FS424C Shelves | Max # of NS224 Shelves |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
144 | 24 | - | 120 | 144 | 120 | - | 96 | N/A | 1 internal + 5 external | 5 external | 5 external | 5 external | 5 external | - | - | - | - |
Capacity Limits
Marketing Max Raw Capacity - Node | HA Pair | Cluster | Effective Capacity - Node | HA Pair | Cluster |
---|---|---|---|---|---|
1603200 | 1603200 | - | - | - | - |
Core Cluster Limits
Max SVM's - NAS | Max LIF's - NAS | Max Connections - NAS | Max Flexible Volumes - NAS | Max Flexible Volumes with DPO - NAS | Max Lock Manager Locked Objects | Max Intercluster LIFs - Node | Min Root Aggregate (MiB) - Node | Min Root Aggregate (with core dump device) (MiB) | Min Root Volume (GiB) - Node | Min Root Volume (with core dump device) (GiB) | Max IPsec Policies | Max # of IPspaces | Max Auditing-Enabled SVMs - Cluster |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Node:- HA Pair:- Cluster:512 | Node:256 HA Pair:256 Cluster:512 | Node:10000 HA Pair(Non-Scalable):10000 | Aggregate (Single data Agg. per Node):- Aggregate (Multiple data Agg. per Node):- Node:1000 HA Pair:2000 Cluster:2000 | Node:- HA Pair:- Cluster:- | Node:70000 HA Pair:70000 Cluster:140000 | - | 226927.04 | 180 | - | - | SVM:- Cluster:- | - | 50 |
System Maximums and Limits
Max Nodes per Cluster (NAS / SAN) | Max FabricPool Size | Max FlexGroup Data Constituent Size | Max Infinite Volume Data Constituent Size | Min Root Volume Size | NetApp Volume Encryption |
---|---|---|---|---|---|
44655 | Not Supported | 60 TiB | Not Supported | 180 GiB | Not Supported |
Processor
Processor Model | Processor Architecture | Processor Speed | Processor Count (Per Node) | Processor Count (Per Config) | Processor Cores (Per CPU) | Processor Cores (Per Node) | Processor Cores (Per Config) |
---|---|---|---|---|---|---|---|
64-bit 2-core with HT | 64 bit | 1.73 Ghz | 1 | 2 | 2 | 2 | 4 |
Memory
NVRAM (Per Node) | NVRAM (Per Config) | NVME (Per Node) | NVME (Per Config) | NVMEM (Per Node) | NVMEM (Per Config) | RAM (Per Node) | RAM (Per Config) |
---|---|---|---|---|---|---|---|
- | - | - | - | 0 GB | 1 GB | 6 GB | 12 GB |
Onboard Ports
Ethernet Ports | Fibre Channel | Ports UTA2 Ports | Expansion Slots | SAS Ports |
---|---|---|---|---|
8 x RJ45 (1Gb) | - | Not Supported | 2 x Mezzanine | 4 x QSFP (6Gb) |
Physical Characteristics
Rack Units | Chassis Height | Chassis Width with Mounting Flanges | Chassis Width without Mounting Flanges | Chassis Depth with Cable Mgmt | Chassis Depth without Cable Mgmt | Chassis Weight |
---|---|---|---|---|---|---|
2 | 3.34" (8.49 cm) | - | 17.61" (44.72 cm) | 23.13" (58.75 cm) | 19.03" (48.34 cm) | See Weights by configuration |
System Clearance Dimensions
Front Clearance (Cooling) | Front Clearance (Maintenance) | Rear Clearance (Cooling) | Rear Clearance (Maintenance) |
---|---|---|---|
22.02" (55.9 cm) | 22.02" (55.9 cm) | 12.02" (30.5 cm) | 12.02" (30.5 cm) |
Environmental Requirements
Operating | Storage | Transit | Acoustic Noise | Input Power Voltage |
---|---|---|---|---|
Tempature: 50 to 104 deg F - 10 to 40 deg C Humidity: 20 to 80 % Altitude: 0.0 to 10000.0 ft - 0.0 to 3048.0 m | Tempature: -40 to 158 deg F - -40 to 70 deg C Humidity: 5 to 95 % Altitude: 0.0 to 40000.0 ft - 0.0 to 12192.0 m | Tempature: -40 to 158 deg F - -40 to 70 deg C Humidity: 5 to 95 % Altitude: 0 to 39989.8 ft - 0 to 12192 m | Sound Power: 6.9 bels Sound Pressure: 51 dBA | 100 to 120 200 to 240 |
Storage OS Requirements
Full OS Matrix | Recommended Version | Minimum OS | Maximum OS |
---|---|---|---|
View Full OS Report Below | 9.1P20 | 9.1RC1 | 9.1P20 |
Storage and Firmware
Full Firmware Matrix | BIOS | BMC |
---|---|---|
Full Firmware Report Below | 8.3* | - |
Product Standards Compliance
Full Compliance and Certificates Report | Cert. EMC/EMI | Cert. Safety | Service Processor Firmware | Cert. Safety/EMC/EMI | Cert. Safety/EMC/EMI/RoHS | Standard Safety/EMC/EMI | Standard Safety |
---|---|---|---|---|---|---|---|
- Below | - | - | - | - | - | - | - |
NFS Cluster Limits
Max Export Policies - Cluster | Max Export Rules - Cluster | Max NFSv4 Access Control Entries | Max Client Objects | Max pNFS objects |
---|---|---|---|---|
12000 | 140000 | 1024 | Node:10000 HA Pair:10000 | Node:524288 HA Pair:524288 Cluster:1048576 |
WAFL Cluster Limits - All Maximums
Size 64-bit Aggregate (TiB) | Size 64-bit Volume (TiB) | File size 64-bit Volume (TiB) | Volume Snapshot Copies | Character length for Snapshot copy names | Hard links - File | inodes/files - Volume | Number of qtrees | Concurrent DataMotion for Volumes ops |
---|---|---|---|---|---|---|---|---|
120 | 60 | 16 | Volume:255 Node:127500 HA Pair:255000 | 255 | 100000 | 2000000000 | Volume:4995 Node:100000 HA Pair:200000 Cluster:400000 | Node:8 HA Pair:16 |
Quality of Service Cluster Limits
Max Policy Groups - Cluster | Max QoS User Workloads - Cluster |
---|---|
12000 | 12000 |
SAN Cluster Limits - All Maximums
# of storage virtual machines (SVMs) - SAN | # of flexible volumes - SAN | # of Flexible Vol with DPO - | # of LUNs | LUN mappings | LUN size (TiB) - LUN | FC queue depth available | # of SAN Hosts (ITNs) | # of LIFS - iSCSI | # of LIFS - FCP | # of igroups | # of Initiators | # of Portsets | # of iSCSI sessions |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Node:125 HA Pair:250 Cluster:500 | Single data Aggregate: Multiple data Aggregates: Node:500 HA Pair:1000 Cluster:2000 | Node:512 HA Pair:- Cluster:- | Valume:- Node:2048 HA Pair:4096 Cluster:8192 | Node:2048 HA Pair:4096 Cluster:8192 | 16 | 2048 | Port:512 Node:2048 HA Pair:4096 Cluster:8192 | Port:32 Portset:32 Node:256 HA Pair:512 Cluster:1024 | Port:32 Portset:32 Node:512 HA Pair:1024 Cluster:2048 | Node:512 HA Pair:1024 Cluster:2048 | igroup:256 Node:1024 HA Pair:2048 Cluster:4096 | Node:512 HA Pair:1024 Cluster:2048 | Node:2048 HA Pair:4096 Cluster:8192 |
CIFS Cluster Limits - All Maximums
# of Connected Shares | # of Regular Shares | # of Open files | # of Local users - Cluster | # of Local groups - Cluster | # of Local group members - Cluster |
---|---|---|---|---|---|
Node:100000 HA Pair:100000 | Node:- HA Pair:- Cluster:40000 | Connection:35000 Node:35000 HA Pair:35000 | 1000 | 1000 | 20000 |
Data Protection Cluster Limits - All Maximums
NDMP Sessions | Data Protection Mirrors | Load Sharing Mirrors - NAS SVM | Concurrent Snap Mirror / SnapVault transfers - Node | DP Mirror fan-out - Volume | LS Mirror fan-out - NAS SVM | # of Clusters that can be peered - Cluster | Volumes, SnapMirror relationship |
---|---|---|---|---|---|---|---|
Node:8 HA Pair (Non-Scalable):8 | Volume:1 Node:1000 HA Pair:2000 Cluster:2000 | 2 | 20 | 8 | 2 | 255 | FlexGroup:32 FlexGroup-Node:- Node:- HA Pair:- Cluster:100 |
Platform LED for FAS2240-2HA
LED Label | LED Name | Type | Status Indicator | Description | |||||
---|---|---|---|---|---|---|---|---|---|
1 | Chassis Attention LED, front | On Amber | The system halted or a fault occurred in the chassis. | The system is operating normally. | |||||
- | - | Off | The system is operating normally. | At least one of the two PSUs is delivering power to the system. | |||||
2 | Chassis Power Config | On Green | At least one of the two PSUs is delivering power to the system. | Neither PSU is delivering power to the system. | |||||
Back View | |||||||||
0a | Port SAS Onboard Config | Link | Green | Link is established on at least one external SAS lane | |||||
- | - | - | Off | No link is established on any external SAS lane | |||||
0b | Port SAS Onboard Config | Link | Green | Link is established on at least one external SAS lane | |||||
- | - | - | Off | No link is established on any external SAS lane | |||||
e0a | Port Ethernet Config | Port Activity | Blinking amber | Traffic is flowing over the connection | |||||
- | - | - | Off | No traffic is flowing over the connection. | |||||
- | - | Port Link | Green | A connection is established on the port | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0b | Port Ethernet Config | Port Activity | Blinking amber | Traffic is flowing over the connection | |||||
- | - | - | Off | No traffic is flowing over the connection. | |||||
- | - | Port Link | Green | A connection is established on the port | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0c | Port Ethernet Config | Port Activity | Blinking amber | Traffic is flowing over the connection | |||||
- | - | - | Off | No traffic is flowing over the connection. | |||||
- | - | Port Link | Green | A connection is established on the port | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0d | Port Ethernet Config | Port Activity | Blinking amber | Traffic is flowing over the connection | |||||
- | - | - | Off | No traffic is flowing over the connection. | |||||
- | - | Port Link | Green | A connection is established on the port | |||||
- | - | - | Off | No connection is established on the port. | |||||
e0M/SP | Port Remote Management Config | - | Blinking amber | Traffic is flowing over the connection. | |||||
- | - | - | Green | A link is established between the port and some upstream device. | |||||
- | - | - | Off | No link is established. | |||||
- | - | - | Off | No traffic is flowing over the connection. | |||||
e0P | Port Private management Config | - | Blinking amber | Traffic is flowing over the connection. | |||||
- | - | - | Green | A link is established between the port and a downstream disk shelf. | |||||
- | - | - | Off | No link is established. |
Supported Shelves Drives for FAS2240-2HA
Part No. | Capacity | RPM | Drive Type | Encryption | Root-Data Partitioning | Root-Data-Data Partitioning | Storage Pool Partitioning | Max Drive Count | FlexArray |
---|---|---|---|---|---|---|---|---|---|
FAS2240-2HA Internal Drives [4] | |||||||||
X341A-R6 | 900GB | 10K | SAS | No | Yes | No | No | 24 | No |
X342A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 24 | No |
X343A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 24 | No |
X356A-R6 | 3.84TB | N/A | SSD | No | No | Yes | Yes | 24 | No |
X357A | 3.84TB | N/A | SSD | No | No | Yes | Yes | 24 | No |
X358A [1] | 3.84TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 24 | No |
X365A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 24 | No |
X371A | 960GB | N/A | SSD | No | No | Yes | Yes | 24 | No |
X416A-R5 [1] [2] | 600GB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 24 | No |
X417A-R6 [1] [2] | 900GB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 24 | No |
X421A-R5 | 450GB | 10K | SAS | No | Yes | No | No | 24 | No |
X422A-R5 | 600GB | 10K | SAS | No | Yes | No | No | 24 | No |
X423A-R5 | 900GB | 10K | SAS | No | Yes | No | No | 24 | No |
X425A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 24 | No |
X426A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 24 | No |
X427A [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 24 | No |
X427B-R6 [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 24 | No |
X438A-R6 | 400GB | N/A | SSD | No | No | Yes | Yes | 24 | No |
X439A-R6 | 1.6TB | N/A | SSD | No | No | Yes | Yes | 24 | No |
X440A-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 24 | No |
X440B-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 24 | No |
X446B-R6 | 200GB | N/A | SSD | No | No | No | Yes | 24 | No |
X447A-R6 | 800GB | N/A | SSD | No | No | Yes | Yes | 24 | No |
DS212C with IOM12 / IOM12 shelf modules | |||||||||
X363A-R6 | 3.84TB | N/A | SSD | No | No | No | Yes | 60 | No |
X364A | 3.84TB | N/A | SSD | No | No | No | Yes | 60 | No |
X366A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 60 | No |
X374A | 960GB | N/A | SSD | No | No | No | Yes | 60 | No |
X448A-R6 | 200GB | N/A | SSD | No | No | No | Yes | 60 | No |
X449A-R6 | 800GB | N/A | SSD | No | No | No | Yes | 60 | No |
X575A-R6 | 400GB | N/A | SSD | No | No | No | Yes | 60 | No |
X576A-R6 | 1.6TB | N/A | SSD | No | No | No | Yes | 60 | No |
X577A-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 60 | No |
X302A-R5 | 1TB | 7.2K | SATA | No | No | No | No | 60 | No |
X306A-R5 | 2TB | 7.2K | SATA | No | No | No | No | 60 | No |
X308A-R5 | 3TB | 7.2K | SATA | No | No | No | No | 60 | No |
X315A-R6 [1] [2] | 4TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | No | No | No | 60 | No |
X317A [1] [3] | 6TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | No | No | No | 60 | No |
X318A-R6 | 8TB | 7.2K | NL-SAS | No | No | No | No | 60 | No |
X322A [1] | 10TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | No | No | No | 60 | No |
X336A-R6 | 4TB | 7.2K | NL-SAS | No | No | No | No | 60 | No |
X339A | 2TB | 7.2K | NL-SAS | No | No | No | No | 60 | No |
X380A | 10TB | 7.2K | NL-SAS | No | No | No | No | 60 | No |
X388A | 16TB | 7.2K | NL-SAS | No | No | No | No | 60 | No |
X477A-R6 | 4TB | 7.2K | NL-SAS | No | No | No | No | 60 | No |
X488A-R5 | 900GB | 10K | SAS | No | No | No | No | 60 | No |
X489A-R6 | 1.2TB | 10K | SAS | No | No | No | No | 60 | No |
X490A-R6 | 1.8TB | 10K | SAS | No | No | No | No | 60 | No |
DS224C with IOM12 / IOM12 shelf modules | |||||||||
X319A | 7.6TB | N/A | SSD | No | No | Yes | No | 72 | No |
X356A-R6 | 3.84TB | N/A | SSD | No | No | Yes | Yes | 72 | No |
X357A | 3.84TB | N/A | SSD | No | No | Yes | Yes | 72 | No |
X358A [1] | 3.84TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 72 | No |
X365A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 72 | No |
X371A | 960GB | N/A | SSD | No | No | Yes | Yes | 72 | No |
X438A-R6 | 400GB | N/A | SSD | No | No | Yes | Yes | 72 | No |
X439A-R6 | 1.6TB | N/A | SSD | No | No | Yes | Yes | 72 | No |
X440A-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 72 | No |
X440B-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 72 | No |
X446A-R6 | 200GB | N/A | SSD | No | No | No | Yes | 72 | No |
X446B-R6 | 200GB | N/A | SSD | No | No | No | Yes | 72 | No |
X447A-R6 | 800GB | N/A | SSD | No | No | Yes | Yes | 72 | No |
X670A | 15.3TB | N/A | SSD | No | No | Yes | No | 72 | No |
X341A-R6 | 900GB | 10K | SAS | No | No | No | No | 120 | No |
X342A-R6 | 1.2TB | 10K | SAS | No | No | No | No | 120 | No |
X343A-R6 | 1.8TB | 10K | SAS | No | No | No | No | 120 | No |
X416A-R5 [1] [2] | 600GB | 10K | SAS | FIPS 140-2 Level 2, NSE | No | No | No | 120 | No |
X417A-R6 [1] [2] | 900GB | 10K | SAS | FIPS 140-2 Level 2, NSE | No | No | No | 120 | No |
X421A-R5 | 450GB | 10K | SAS | No | No | No | No | 120 | No |
X422A-R5 | 600GB | 10K | SAS | No | No | No | No | 120 | No |
X423A-R5 | 900GB | 10K | SAS | No | No | No | No | 120 | No |
X425A-R6 | 1.2TB | 10K | SAS | No | No | No | No | 120 | No |
X426A-R6 | 1.8TB | 10K | SAS | No | No | No | No | 120 | No |
X427A [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | No | No | No | 120 | No |
X427B-R6 [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | No | No | No | 120 | No |
DS2246 [4] with IOM6 / IOM6 shelf modules | |||||||||
X356A-R6 | 3.84TB | N/A | SSD | No | No | Yes | Yes | 72 | No |
X357A | 3.84TB | N/A | SSD | No | No | Yes | Yes | 72 | No |
X358A [1] | 3.84TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 72 | No |
X365A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 72 | No |
X371A | 960GB | N/A | SSD | No | No | Yes | Yes | 72 | No |
X438A-R6 | 400GB | N/A | SSD | No | No | Yes | Yes | 72 | No |
X439A-R6 | 1.6TB | N/A | SSD | No | No | Yes | Yes | 72 | No |
X440A-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 72 | No |
X440B-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | Yes | Yes | 72 | No |
X446B-R6 | 200GB | N/A | SSD | No | No | No | Yes | 72 | No |
X447A-R6 | 800GB | N/A | SSD | No | No | Yes | Yes | 72 | No |
X341A-R6 | 900GB | 10K | SAS | No | Yes | No | No | 120 | No |
X342A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 120 | No |
X343A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 120 | No |
X416A-R5 [1] [2] | 600GB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 120 | No |
X417A-R6 [1] [2] | 900GB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 120 | No |
X421A-R5 | 450GB | 10K | SAS | No | Yes | No | No | 120 | No |
X422A-R5 | 600GB | 10K | SAS | No | Yes | No | No | 120 | No |
X423A-R5 | 900GB | 10K | SAS | No | Yes | No | No | 120 | No |
X425A-R6 | 1.2TB | 10K | SAS | No | Yes | No | No | 120 | No |
X426A-R6 | 1.8TB | 10K | SAS | No | Yes | No | No | 120 | No |
X427A [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 120 | No |
X427B-R6 [1] | 1.8TB | 10K | SAS | FIPS 140-2 Level 2, NSE | Yes | No | No | 120 | No |
DS4246 [4] with IOM6 / IOM6 shelf modules | |||||||||
X363A-R6 | 3.84TB | N/A | SSD | No | No | No | Yes | 72 | No |
X366A-R6 [1] | 1.6TB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 72 | No |
X374A | 960GB | N/A | SSD | No | No | No | Yes | 72 | No |
X441A-R5 | 100GB | N/A | SSD | No | No | No | No | 72 | No |
X442A-R5 [5] | 100GB | N/A | SSD | No | No | No | No | 72 | No |
X448A-R6 | 200GB | N/A | SSD | No | No | No | Yes | 72 | No |
X449A-R6 | 800GB | N/A | SSD | No | No | No | Yes | 72 | No |
X575A-R6 | 400GB | N/A | SSD | No | No | No | Yes | 72 | No |
X576A-R6 | 1.6TB | N/A | SSD | No | No | No | Yes | 72 | No |
X577A-R6 [1] | 800GB | N/A | SSD | FIPS 140-2 Level 2, NSE | No | No | Yes | 72 | No |
X302A-R5 | 1TB | 7.2K | SATA | No | No | No | No | 120 | No |
X306A-R5 | 2TB | 7.2K | SATA | No | No | No | No | 120 | No |
X308A-R5 | 3TB | 7.2K | SATA | No | No | No | No | 120 | No |
X309A-R6 [1] [2] | 3TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | No | No | No | 120 | No |
X310A-R5 | 500GB | 7.2K | SATA | No | No | No | No | 120 | No |
X315A-R6 [1] [2] | 4TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | No | No | No | 120 | No |
X316A-R6 | 6TB | 7.2K | NL-SAS | No | No | No | No | 120 | No |
X317A [1] [3] | 6TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | No | No | No | 120 | No |
X318A-R6 | 8TB | 7.2K | NL-SAS | No | No | No | No | 120 | No |
X322A [1] | 10TB | 7.2K | NL-SAS | FIPS 140-2 Level 2, NSE | No | No | No | 120 | No |
X336A-R6 | 4TB | 7.2K | NL-SAS | No | No | No | No | 120 | No |
X380A | 10TB | 7.2K | NL-SAS | No | No | No | No | 120 | No |
X410A-R5 | 300GB | 15K | SAS | No | No | No | No | 120 | No |
X411A-R5 | 450GB | 15K | SAS | No | No | No | No | 120 | No |
X412A-R5 | 600GB | 15K | SAS | No | No | No | No | 120 | No |
X414A-R5 [1] [2] | 600GB | 15K | SAS | FIPS 140-2 Level 2, NSE | No | No | No | 120 | No |
X477A-R6 | 4TB | 7.2K | NL-SAS | No | No | No | No | 120 | No |
X488A-R5 | 900GB | 10K | SAS | No | No | No | No | 120 | No |
X489A-R6 | 1.2TB | 10K | SAS | No | No | No | No | 120 | No |
X490A-R6 | 1.8TB | 10K | SAS | No | No | No | No | 120 | No |
DS4243 [4] with IOM3 / IOM6 / IOM6 / IOM3 shelf modules | |||||||||
X441A-R5 | 100GB | N/A | SSD | No | No | No | No | 72 | No |
X442A-R5 [5] | 100GB | N/A | SSD | No | No | No | No | 72 | No |
X302A-R5 | 1TB | 7.2K | SATA | No | No | No | No | 120 | No |
X306A-R5 | 2TB | 7.2K | SATA | No | No | No | No | 120 | No |
X308A-R5 | 3TB | 7.2K | SATA | No | No | No | No | 120 | No |
X310A-R5 | 500GB | 7.2K | SATA | No | No | No | No | 120 | No |
X410A-R5 | 300GB | 15K | SAS | No | No | No | No | 120 | No |
X411A-R5 | 450GB | 15K | SAS | No | No | No | No | 120 | No |
X412A-R5 | 600GB | 15K | SAS | No | No | No | No | 120 | No |
X414A-R5 [1] [2] | 600GB | 15K | SAS | FIPS 140-2 Level 2, NSE | No | No | No | 120 | No |
Footnote: | |||||||||
[1] Mixing NSE drives or shelves with any other type of encrypting or non-encrypting drives or shelves across a stand-alone platform or high-availability (HA) pair is not supported. | |||||||||
[2] In Flash Pool NSE SSD drives can only be used with NSE HDD drives. | |||||||||
[3] Mixing encrypted with unencrypted drives or shelves across a stand-alone platform or high-availability (HA) pair is not supported. | |||||||||
[4] Total number of SSD drives cannot exceed 96 drives on the FAS2240. However, other drive types (SAS/SATA/NL-SAS) can be added to these system to achieve the maximum drive count of 144 drives. | |||||||||
[5] This drive does not support the sanitization feature. |
Supported RAID Configurations - FAS2240-2HA
Drive Type | Drive Capacity Min | Drive Capacity Max | Minimum | Default | Maximum | ||||
---|---|---|---|---|---|---|---|---|---|
Data Aggregate | |||||||||
RAID4 | |||||||||
NL-SAS | 0 TB | 8 TB | 3 | 7 | 7 | ||||
SAS | 0 TB | 5.999 TB | 3 | 8 | 14 | ||||
SATA | 0 TB | 5.999 TB | 3 | 7 | 7 | ||||
SSD | 0 TB | 5.999 TB | 3 | 8 | 14 | ||||
RAID-DP | |||||||||
NL-SAS | 0 TB | 5.999 TB | 5 | 14 | 20 | ||||
NL-SAS | 6 TB | 8 TB | 5 | 14 | 14 | ||||
SAS | 0 TB | 5.999 TB | 5 | 16 | 28 | ||||
SATA | 0 TB | 5.999 TB | 5 | 14 | 20 | ||||
SSD | 0 TB | 5.999 TB | 5 | 23 | 28 | ||||
RAID-TEC | |||||||||
NL-SAS | 0 TB | 10 TB | 7 | 21 | 29 | ||||
SAS | 0 TB | 8 TB | 7 | 24 | 29 | ||||
SATA | 0 TB | 8 TB | 7 | 21 | 29 | ||||
SSD | 0 TB | 8 TB | 7 | 24 | 29 | ||||
Root Aggregate | |||||||||
RAID4 | |||||||||
NL-SAS | 0 TB | 8 TB | 2 | - | 7 | ||||
SAS | 0 TB | 5.999 TB | 2 | - | 14 | ||||
SATA | 0 TB | 5.999 TB | 2 | - | 7 | ||||
SSD | 0 TB | 5.999 TB | 2 | - | 14 | ||||
RAID-DP | |||||||||
NL-SAS | 0 TB | 5.999 TB | 3 | - | 20 | ||||
NL-SAS | 6 TB | 8 TB | 3[1] | - | 14 | ||||
SAS | 0 TB | 5.999 TB | 3[2] | - | 28 | ||||
SATA | 0 TB | 5.999 TB | 3[2] | - | 20 | ||||
SSD | 0 TB | 5.999 TB | 3 | - | 28 | ||||
RAID-TEC | |||||||||
NL-SAS | 0 TB | 10 TB | 7 | - | 29 | ||||
SAS | 0 TB | 8 TB | 7 | - | 29 | ||||
SATA | 0 TB | 8 TB | 7 | - | 29 | ||||
SSD | 0 TB | 8 TB | 7 | - | 29 | ||||
Footnote: | |||||||||
[1] RAID-DP is supported with 10TB NL-SAS drives only if HA pair has 10-14 drives | |||||||||
[2] The minimum number of disks in a RAID-DP group is three: at least one data disk, one regular parity disk, and one double-parity (dParity) disk. However, for non-root aggregates with only one RAID group, you must have at least 5 disks (three data disks and two parity disks). |
Supported Adapter Cards - FAS2240-2HA
Priority | Category | Bus Type | Mktg Part No. | Mfg Part No | Description | Plug Type | Optical Module Included? | Cables | Supported Protocol(s) | Min ONTAP | Max Qty [1] | Priority Slot Assignment | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Networking | Mezzanine | X1160A-R6 [2] | 111-00810 | 2p 10GbE NIC Op | 111-00810 | 2p 10GbE NIC Op | SFP+ | Ethernet 10Gb | View | Ethernet 10Gb | 9.0RC1, 9.1RC1, 8.1, 8.2RC1, 8.3RC1 | |||||||
Footnote: | |||||||||||||||||||
[1] Values shown for max quantity are per controller. HA configurations will support 2x the values shown. | |||||||||||||||||||
[2] Requires X6589-R6 SFP+ optical module or copper twinax cable. The X6589-R6 SFP+ module is optional and NOT included with the 10GbE mezzanine adapter by default. See Ethernet Ports Usage table for Cluster-Mode port assignment. |
Supported Connections for FAS2240-2HA
Configuration Type | Port Configuration | Image | Cluster Ports per Node | Switch Ports per Node | |||||
---|---|---|---|---|---|---|---|---|---|
Cluster Interconnect | |||||||||
2-node Switchless Cluster | Default, Minimum, Recommended | N/A | 2 | None | |||||
Switched 10GbE Interconnect | Default, Minimum, Recommended | N/A | 2 | 2 | |||||
Switched 40GbE Interconnect (10GbE breakout) | Default, Recommended | N/A | 2 | 1 |
Platform Mixing Rules: FAS2240-2HA
Platform Configuration Type | Maximum Nodes (NAS) [1] | Maximum Nodes (SAN) [1] | Min ONTAP Version for Platform Mixing | ||||||
---|---|---|---|---|---|---|---|---|---|
FAS - Legacy EOA Configuration(s) | |||||||||
FAS2220A | 4 Nodes | Not Supported | 9.0RC1 | ||||||
FAS2240-2HA | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
FAS2240-4HA | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
FAS2520HA | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
FAS2552HA | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
FAS2554HA | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
FAS2620A | 4 Nodes | 4 Nodes | 9.1 | ||||||
FAS2650A | 4 Nodes | 4 Nodes | 9.1RC1 | ||||||
FAS3220A | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
FAS3220AE | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
FAS3250AE | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
FAS3270A | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
FAS3270AE | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
FAS6210A | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
FAS6220A | 4 Nodes | 4 Nodes | 9.1 | ||||||
FAS6240A | 4 Nodes | 4 Nodes | 9.1 | ||||||
FAS6250A | 4 Nodes | 4 Nodes | 9.1 | ||||||
FAS6280A | 4 Nodes | 4 Nodes | 9.1 | ||||||
FAS6290A | 4 Nodes | 4 Nodes | 9.1 | ||||||
FAS8020A | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
FAS8040A | 4 Nodes | 4 Nodes | 9.1 | ||||||
FAS8060A | 4 Nodes | 4 Nodes | 9.1 | ||||||
FAS8060AE | 4 Nodes | 4 Nodes | 9.1 | ||||||
FAS8080AE EX | 4 Nodes | 4 Nodes | 9.1 | ||||||
FAS8200A | 4 Nodes | 4 Nodes | 9.1RC1 | ||||||
AllFlashFAS - Legacy EOA Configuration(s) | |||||||||
AFF A200A | 4 Nodes | 4 Nodes | 9.1RC2 | ||||||
AFF A300A | 4 Nodes | 4 Nodes | 9.1RC1 | ||||||
AFF8020A | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
AFF8040A | 4 Nodes | 4 Nodes | 9.1 | ||||||
AFF8060A | 4 Nodes | 4 Nodes | 9.1 | ||||||
AFF8060AE | 4 Nodes | 4 Nodes | 9.1 | ||||||
AFF8080A EX | 4 Nodes | 4 Nodes | 9.1 | ||||||
AFF8080AE EX | 4 Nodes | 4 Nodes | 9.1 | ||||||
V-Series - Legacy EOA Configuration(s) | |||||||||
V3220A | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
V3220AE | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
V3250AE | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
V3270A | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
V3270AE | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
V6210A | 4 Nodes | 4 Nodes | 9.0RC1 | ||||||
V6220A | 4 Nodes | 4 Nodes | 9.1 | ||||||
V6240A | 4 Nodes | 4 Nodes | 9.1 | ||||||
V6250A | 4 Nodes | 4 Nodes | 9.1 | ||||||
V6280A | 4 Nodes | 4 Nodes | 9.1 | ||||||
V6290A | 4 Nodes | 4 Nodes | 9.1 | ||||||
Footnote: | |||||||||
[1] Maximum number of nodes within a cluster is determined by platform which supports the fewest number of nodes |
Product Standard Compliance - FAS2240-2HA
Standard | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|
No Information Found |
Supported OS Version - FAS2240-2HA
OS Major Version | Supported OS Version | Supported Milestones | Recommend Version | ||||||
---|---|---|---|---|---|---|---|---|---|
EOS OS | |||||||||
Clustered Data ONTAP 8.3 | 8.3.2P12, 8.3.2P11, 8.3.2P10, 8.3.2P9, 8.3.2P8, 8.3.2P7, 8.3.2P6, 8.3.2P5, 8.3.2P4, 8.3.2P3, 8.3.2P2, 8.3.2P1, 8.3.2, 8.3.2RC2, 8.3.1P2, 8.3.1P1, 8.3.1, 8.3.1RC1, 8.3P2, 8.3P1, 8.3, 8.3RC2, 8.3RC1 | End of Full Support: 31-Oct-2017 End of Limited Support: 30-Apr-2019 End of Self-Service Support: 30-Apr-2022 | 8.3.2P12 | ||||||
Clustered Data ONTAP 8.2 | 8.2.4P6, 8.2.4P5, 8.2.4P4, 8.2.4P3, 8.2.4P2, 8.2.4P1, 8.2.4, 8.2.3P6, 8.2.3P5, 8.2.3P4, 8.2.3P3, 8.2.3P2, 8.2.3P1, 8.2.3, 8.2.2P2, 8.2.2P1, 8.2.2, 8.2.2RC2, 8.2.2RC1, 8.2.1P3, 8.2.1P2, 8.2.1P1, 8.2.1, 8.2.1RC2, 8.2.1RC1, 8.2P6, 8.2P5, 8.2P4, 8.2P3, 8.2P2, 8.2, 8.2RC1 | End of Full Support: 31-Jul-2017 End of Limited Support: 31-Jan-2019 End of Self-Service Support: 31-Jan-2022 | 8.2.4P6 | ||||||
7-Mode 8.2 | 8.2.5P5, 8.2.5P4, 8.2.5P3, 8.2.5P2, 8.2.5P1, 8.2.5, 8.2.4P6, 8.2.4P5, 8.2.4P4, 8.2.4P3, 8.2.4P2, 8.2.4P1, 8.2.4, 8.2.3P6, 8.2.3P5, 8.2.3P4, 8.2.3P3, 8.2.3P2, 8.2.3P1, 8.2.3, 8.2.2, 8.2.2RC2, 8.2.2RC1, 8.2.1, 8.2.1RC2, 8.2.1RC1, 8.2, 8.2RC1 | End of Full Support: 31-Dec-2020 End of Limited Support: 31-Dec-2022 End of Self-Service Support: 31-Dec-2025 | 8.2.5P5 | ||||||
7-Mode 8.1 | 8.1.4P10, 8.1.4P9, 8.1.4P8, 8.1.4P7, 8.1.4P6, 8.1.4P5, 8.1.4P4, 8.1.4P3, 8.1.4P2, 8.1.4P1, 8.1.4, 8.1.3P3, 8.1.3P2, 8.1.3P1, 8.1.3, 8.1.3RC1, 8.1.2P4, 8.1.2P3, 8.1.2P2, 8.1.2P1, 8.1.2, 8.1.2RC2, 8.1.1P2, 8.1.1P1, 8.1.1, 8.1.1RC1, 8.1P3, 8.1P2, 8.1P1, 8.1 | End of Full Support: 30-Aug-2015 End of Limited Support: 28-Feb-2017 End of Self-Service Support: 28-Feb-2020 | 8.1.4P10 | ||||||
Clustered Data ONTAP 8.1 | 8.1.4P10, 8.1.4P9, 8.1.4P8, 8.1.4P7, 8.1.4P6, 8.1.4P5, 8.1.4P4, 8.1.4P3, 8.1.4P2, 8.1.4P1, 8.1.4, 8.1.3P3, 8.1.3P2, 8.1.3P1, 8.1.3, 8.1.3RC1, 8.1.2P4, 8.1.2P3, 8.1.2P2, 8.1.2P1, 8.1.2, 8.1.2RC2, 8.1.1P2, 8.1.1P1, 8.1.1, 8.1.1RC1, 8.1P3, 8.1P2, 8.1P1, 8.1 | End of Full Support: 30-Aug-2015 End of Limited Support: 28-Feb-2017 End of Self-Service Support: 28-Feb-2020 | 8.1.4P10 | ||||||
ONTAP 9.1 | 9.1P20, 9.1P19, 9.1P18, 9.1P17, 9.1P16, 9.1P15, 9.1P14, 9.1P13, 9.1P12, 9.1P11, 9.1P10, 9.1P9, 9.1P8, 9.1P7, 9.1P6, 9.1P5, 9.1P3, 9.1P2, 9.1P1, 9.1, 9.1RC2, 9.1RC1 | End of Full Support: 31-Jan-2020 End of Limited Support: 31-Jan-2022 End of Self-Service Support: 31-Jan-2025 | 9.1P20 | ||||||
Definitions: | |||||||||
[1]End of Full Support: The date marking the end of Full Support for a particular feature version of a NetApp system software and the beginning of Limited Support. Abbreviated as EOES. | |||||||||
[2]End of Limited Support: The date marking the end of Limited Support for a particular feature version of a product and transition to Self-Service Support. Abbreviated as EOVS. | |||||||||
[3]End of Self-Service Support: NetApp does not provide support for a version of a software product, but related documentation is still available on the NetApp Support Site. NetApp customers are expected to utilize documentation to resolve issues. |
Supported Power Cords for FAS2240-2HA
Marketing Part No. | End 1 / End 2 | Length | Description | |
---|---|---|---|---|
Non-Cabinet Power Cords | ||||
X800B-R6 | CEE 7/7 (Schuko) / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Cont Europe/Korea,10A/250V | |
X800C-R6 | BS1363 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,UK/Ireland,10A/250V | |
X800D-R6 | JIS-C-8303 / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,Japan,15A/125V | |
X800E-R6 | NEMA 5-15P / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,North America,15A/125V | |
X800F-R6 | AS/NZS 3112 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Aus/NZ,10A/250V | |
X800G-R6 | SEV 1011 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Switzerland,10A/250V | |
X800H-R6 | IRAM 2073 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Argentina,10A/250V | |
X800I-R6 | GB2099 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,China,10A/250V | |
X800J-R6 | DHCR107-2-D1 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Demark,10A/250V | |
X800K-R6 | SANS 164-1 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,India/S.Africa,10A/250V | |
X800L-R6 | SI32 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Israel,10A/250V | |
X800M-R6 | CEI 23-16 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Italy,10A/250V | |
X800P-R6 | NEMA 6-15P / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,North America,15A/250V | |
X800T-R6 | CNS 10917-3 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Taiwan,BSMI,15A/125V | |
X800VB-R6 | NBR14136 / IEC60320-C13 | 2.50 m | Pwr Cord,Non-Cabinet,Brazil,10A/250V | |
X800W-R6 | CNS10917/CNS690 / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,Taiwan,10A/250V | |
X800Y-R6 | JIS-C-830 / IEC60320-C13 | 1.83 m | Pwr Cord,Non-Cabinet,Japan,15A/250V | |
In-Cabinet Power Cords | ||||
X1558A-R6 | IEC60320-C14 / IEC60320-C13 | 1.20 m | Pwr Cord,In-Cabinet,48-In,C13-C14,10A/250V | |
X800-42U-35 | IEC60320-C14 / IEC60320-C13 | 0.89 m | Pwr Cord,In-Cabinet,C13-C14,35-inch | |
X800-42U-43 | IEC60320-C14 / IEC60320-C13 | 1.09 m | Pwr Cord,In-Cabinet,C13-C14,43-inch | |
X800-42U-64 | IEC60320-C14 / IEC60320-C13 | 1.63 m | Pwr Cord,In-Cabinet,C13-C14,64-inch | |
X800-42U-R6 | IEC60320-C14 / IEC60320-C13 | 0.68 m | Pwr Cord,In-Cabinet,27-In,C13-C14,10A/250V |
Onboard Ports Configuration: FAS2240-2HA
Port Address | Description | Supported Protocols | Port Icon | Port Type | |||||
---|---|---|---|---|---|---|---|---|---|
0a [1] | Serial-Attached SCSI | SAS 3/6 Gb | SAS | QSFP | |||||
0b [1] | Serial-Attached SCSI | SAS 3/6 Gb | SAS | QSFP | |||||
e0a | Ethernet | Ethernet 10/100/1000 Mb | Ethernet | RJ45 | |||||
e0b | Ethernet | Ethernet 10/100/1000 Mb | Ethernet | RJ45 | |||||
e0c | Ethernet | Ethernet 10/100/1000 Mb | Ethernet | RJ45 | |||||
e0d | Ethernet | Ethernet 10/100/1000 Mb | Ethernet | RJ45 | |||||
e0M/SP [2] | Management | Ethernet 10/100 Mb | Wrench | RJ45 | |||||
e0P | Private Management | Ethernet 10/100 Mb | Wrench w/Padlock | RJ45 | |||||
Serial Interface Icon [3] | Serial Console | RS-232 9600bps | Serial Interface | RJ45 | |||||
Footnote: | |||||||||
[1] 0a (circle) is Expander port, 0b (square) is HBA port.SAS tape supported | |||||||||
[2] Default management port | |||||||||
[3] RS232, RJ45 connector |
Supported Platform Configurations - FAS2240-2HA
Platform Configuration | Description | Chassis Configuration | Chassis Count | Controller Count (per chassis) | IOXM Count (per chassis) | Rack Units (Per System) | Weight (Per Chassis) | Min ONTAP | |
---|---|---|---|---|---|---|---|---|---|
Stand Alone | |||||||||
FAS2240-2 | FAS2240-2 Single Node | Cb | 1 | 1 | 0 | 2 | 37.48 lb (17 kg) | 9.0RC1, 9.1RC1 | |
HA Pair | |||||||||
FAS2240-2HA | FAS2240-2 Single Chassis HA Pair | CC | 1 | 2 | 0 | 2 | 42.55 lb (19.3 kg) | 9.0RC1, 9.1RC1 |
Platform Memory Specifications - FAS2240-2HA
Part Number | Description | Mfg Part Number | Non-Volatile | Qty | Capacity (GB) | NVRAM/NVMEM Used Capacity (GB) | RAM Used Capacity (GB) |
---|---|---|---|---|---|---|---|
X3208A-R6 | 4GB DIMM, ECC, DDR3-800, System | 107-00100 | no | 2 | 4 | - | 12 |
X3209A-R6 | 2GB DIMM, ECC, DDR3-800, NVMEM Slot | 107-00099 | yes | 2 | 2 | 1.53 | - |
Supported Rail Kit for FAS2240-2HA
Marketing Part No. | Manufacturing Part No. | Description | |
---|---|---|---|
NetApp System Cabinet Rail Kits | |||
X877B-R6 | 111-00596 | Rail Kit II, NetApp Cabinet, R6 | |
X8783A-R6 | 111-01110 | Rail Kit III, NetApp Cabinet, R6 | |
Third-Party Cabinet Rail Kits | |||
X-02659-00 | 113-00232 | Kit,4-Post,Square or Round-Hole, 24"-32" Rail | |
X5515A-R6 [1] | 111-00232 | Kit,2-Post (Round) or 4-Post (Square), 24"-32" Rail | |
X5526A-R6 | 111-00593 | Kit,4-Post.Square-Hole, 24"-32" Rail | |
X5527A-R6 | 111-00864 | Kit,2-Post,Round-Hole | |
X5529A-R6 | 111-00310 | Kit,4-Post,Swift,Square-Hole, 24"-32" Rail |
Field Replacement Unit Parts - FAS2240-2HA
Marketing Part No. | Manufacturing Part No. | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Adapter Card | ||||||||||
X1160A-R6 [1] | 111-00810 | CARD Mezzanine 2-port 10GbE | ||||||||
Battery | ||||||||||
X1847 | 271-01847 | Lithium System Battery CR2032 | ||||||||
X1847-R6 | 271-01847 | Lithium System Battery CR2032,R6 | ||||||||
X3117A-R6 | 111-00908 | Battery,FAS22XX,FAS25XX,NVMEM | ||||||||
Bezel | ||||||||||
X80067A-R6 | 111-00814 | Bezel,2U,FAS2240,R6 | ||||||||
Blank | ||||||||||
X5055-R6 | 111-00812 | BLANK,CHASSIS FILLER,REAR,DS2246,R6 | ||||||||
Boot Media | ||||||||||
X1425A-R6 | N/A | MEM,USB Media,2GB,Blank | ||||||||
Chassis | ||||||||||
X559A-R6 | 111-00804 | SHELF,EMPTY,2PSU,AC,DS2246,R6 | ||||||||
Data Cable | ||||||||||
X-SFP-H10GB-CU1M-R6 | 112-00210 | Cable,10GBase Copper SFP+ 1m | ||||||||
X-SFP-H10GB-CU1M-R6-C | 112-00210 | Cable,10GBase Copper SFP+ 1m,-C | ||||||||
X-SFP-H10GB-CU1M-R6-N-C | 112-00210 | Cable,10GBase Copper SFP+ 1m,-C | ||||||||
X-SFP-H10GB-CU3M-R6 | 112-00211 | Cable,10GBase Copper SFP+ 3m | ||||||||
X-SFP-H10GB-CU3M-R6-C | 112-00211 | Cable,10GBase Copper SFP+ 3m,-C | ||||||||
X-SFP-H10GB-CU3M-R6-N-C | 112-00211 | Cable,10GBase Copper SFP+ 3m,-C | ||||||||
X-SFP-H10GB-CU5M-R6 | 112-00212 | Cable,10GBase Copper SFP+ 5m | ||||||||
X-SFP-H10GB-CU5M-R6-C | 112-00212 | Cable,10GBase Copper SFP+ 5m,-C | ||||||||
X-SFP-H10GB-CU5M-R6-N-C | 112-00212 | Cable,10GBase Copper SFP+ 5m,-C | ||||||||
X6536-R6 | 112-00090 | Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op | ||||||||
X6536-R6-C | 112-00090 | Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op,-C | ||||||||
X6536-R6-N-C | 112-00090 | Cable,Cntlr-Shelf/Switch,5m,LC/LC,Op,-C | ||||||||
X6537-R6 | 112-00091 | Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op | ||||||||
X6537-R6-C | 112-00091 | Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op,-C | ||||||||
X6537-R6-N-C | 112-00091 | Cable,Cntlr-Shelf/Switch,30m,LC/LC,Op,-C | ||||||||
X6546-R6 | 112-00074 | Cable,Cntlr-Shelf/Switch,30m,LC/SC,Op | ||||||||
X6547-R6 | 112-00073 | Cable,Cntlr-Shelf/Switch,5m,LC/SC,Op | ||||||||
X6553-R6 | 112-00188 | Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op | ||||||||
X6553-R6-C | 112-00188 | Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op,-C | ||||||||
X6553-R6-N-C | 112-00188 | Cable,Cntlr-Shelf/Switch,2m,LC/LC,Op,-C | ||||||||
X6554-R6 | 112-00189 | Cable,Cntlr-Shelf/Switch,15m,LC/LC,Op | ||||||||
X6554-R6-C | 112-00189 | Cable,OPT,50u,2GHz/KM,MM,LC/LC,15M,-C,R6 | ||||||||
X6554-R6-N-C | 112-00189 | Cable,OPT,50u,2GHz/KM,MM,LC/LC,15M,-C,R6,-C | ||||||||
X6557-EN-R6-C | 112-00176 | Cbl,SAS Cntlr-Shelf/Shelf-Shelf/HA,0.5m,EN,-C | ||||||||
X6557-R6 | 112-00176 | Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,0.5m | ||||||||
X6557-R6-C | 112-00176 | Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,0.5m,-C | ||||||||
X6558-EN-R6-C | 112-00177 | Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,2m,-C | ||||||||
X6558-R6 | 112-00177 | Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,2m | ||||||||
X6558-R6-C | 112-00177 | Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,2m,-C | ||||||||
X6559-EN-R6-C | 112-00178 | Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,5m,-C | ||||||||
X6559-R6 | 112-00178 | Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,5m | ||||||||
X6559-R6-C | 112-00178 | Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,5m,-C | ||||||||
X6560-R6 | 112-00194 | Cable,Ethernet,0.5m RJ45 CAT6 | ||||||||
X6560-R6-C | 112-00194 | Cable,Ethernet,0.5m RJ45 CAT6,-C | ||||||||
X6560-R6-N-C | 112-00194 | Cable,Ethernet,0.5m RJ45 CAT6 | ||||||||
X6561-R6 | 112-00195 | Cable,Ethernet,2m RJ45 CAT6 | ||||||||
X6561-R6-C | 112-00195 | Cable,Ethernet,2m RJ45 CAT6,-C | ||||||||
X6561-R6-N-C | 112-00195 | Cable,Ethernet,2m RJ45 CAT6,-C | ||||||||
X6562-R6 | 112-00196 | Cable,Ethernet,5m RJ45 CAT6 | ||||||||
X6562-R6-C | 112-00196 | Cable,Ethernet,5m RJ45 CAT6,-C | ||||||||
X6562-R6-N-C | 112-00196 | Cable,Ethernet,5m RJ45 CAT6,-C | ||||||||
X6566B-05-N-C | 112-00297 | Cable,Direct Attach CU SFP+ 10G,0.5M,-C | ||||||||
X6566B-05-R6 | 112-00297 | Cable,Direct Attach CU SFP+ 10G,0.5M | ||||||||
X6566B-05-R6-C | 112-00297 | Cable,Direct Attach CU SFP+ 10G,0.5M,-C | ||||||||
X6566B-2-N-C | 112-00299 | Cable,Direct Attach CU SFP+ 10G,2M,-C | ||||||||
X6566B-2-R6 | 112-00299 | Cable,Direct Attach CU SFP+ 10G,2M | ||||||||
X6566B-2-R6-C | 112-00299 | Cable,Direct Attach CU SFP+ 10G,2M,-C | ||||||||
X6566B-3-N-C | 112-00300 | Cable,Direct Attach CU SFP+ 10G,3M,-C | ||||||||
X6566B-3-R6 | 112-00300 | Cable,Direct Attach CU SFP+ 10G,3M | ||||||||
X6566B-3-R6-C | 112-00300 | Cable,Direct Attach CU SFP+ 10G,3M,-C | ||||||||
X6566B-5-N-C | 112-00301 | Cable,Direct Attach CU SFP+ 10G,5M,-C | ||||||||
X6566B-5-R6 | 112-00301 | Cable,Direct Attach CU SFP+ 10G,5M | ||||||||
X6566B-5-R6-C | 112-00301 | Cable,Direct Attach CU SFP+ 10G,5M,-C | ||||||||
X6577-R6 | 112-00238 | Cable,Ethernet,30m RJ45 CAT6 | ||||||||
X6577-R6-C | 112-00238 | Cable,Ethernet,30m RJ45 CAT6,-C | ||||||||
X6577-R6-N-C | 112-00238 | Cable,Ethernet,30m RJ45 CAT6,-C | ||||||||
X6585-R6 | 112-00291 | Cable,Ethernet,3m RJ45 CAT6 | ||||||||
X6585-R6-C | 112-00291 | Cable,Ethernet,3m RJ45 CAT6,-C | ||||||||
X6585-R6-N-C | 112-00291 | Cable,Ethernet,3m RJ45 CAT6,-C | ||||||||
X6590-R6 | 112-00242 | Cable,SAS Cntlr-Shelf/Shelf-Shelf,10m | ||||||||
X6591-R6 | 112-00243 | Cable,SAS Cntlr-Shelf/Shelf-Shelf,20m | ||||||||
X6592-R6 | 112-00246 | Cable,Ethernet,10m RJ45 CAT6 | ||||||||
X6592-R6-N-C | 112-00246 | Cable,Ethernet,10m RJ45 CAT6,-C | ||||||||
X6593-R6 | 112-00247 | Cable,Ethernet,20m RJ45 CAT6 | ||||||||
X6593-R6-C | 112-00247 | Cable,Ethernet,20m RJ45 CAT6,-C | ||||||||
X6593-R6-N-C | 112-00247 | Cable,Ethernet,20m RJ45 CAT6,-C | ||||||||
X6594-R6 | 112-00256 | Cable,SAS Cntlr-Shelf/Shelf-Shelf,HA,1m | ||||||||
X6594-R6-C | 112-00256 | Cable,SAS Cntlr-Shelf/Shelf-Shelf,HA,1m,-C | ||||||||
X6595-R6 | 112-00255 | Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,3m | ||||||||
X6595-R6-C | 112-00255 | Cable,SAS Cntlr-Shelf/Shelf-Shelf/HA,3m,-C | ||||||||
X66020A-R6 | 112-00429 | Cable,Storage,MiniSAS HD,QSFP,12G,1m | ||||||||
X66020A-R6-C | 112-00429 | Cable,Storage,MiniSAS HD,QSFP,12G,1m,-C | ||||||||
X66021A-R6 | 112-00430 | Cable,Storage,MiniSAS HD,QSFP,12G,2m | ||||||||
X66021A-R6-C | 112-00430 | Cable,Storage,MiniSAS HD,QSFP,12G,2m,-C | ||||||||
X66022A-R6 | 112-00431 | Cable,Storage,MiniSAS HD,QSFP,12G,5m | ||||||||
X66022A-R6-C | 112-00431 | Cable,Storage,MiniSAS HD,QSFP,12G,5m,-C | ||||||||
X66120-3 | 112-00545 | Cable,Direct Attach CU 40G QSFP/4x10G SFP,3m | ||||||||
X66120-3-C | 112-00545 | Cable,Dir. Attach CU 40G QSFP/4x10G SFP,3m,-C | ||||||||
X66120-3-N-C | 112-00545 | Cable,Dir Attach CU 40G QSFP/4x10G SFP,3m,-C | ||||||||
X66120-5 | 112-00546 | Cable,Direct Attach CU 40G QSFP/4x10G SFP,5m | ||||||||
X66120-5-C | 112-00546 | Cable,Dir. Attach CU 40G QSFP/4x10G SFP,5m,-C | ||||||||
X66120-5-N-C | 112-00546 | Cable,Dir Attach CU 40G QSFP/4x10G SFP,5m,-C | ||||||||
X66205-30 | 112-00261 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m | ||||||||
X66205-30-C | 112-00261 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m,-C | ||||||||
X66205-30-N-C | 112-00261 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,30m,-C | ||||||||
X66205-5 | 112-00260 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m | ||||||||
X66205-5-C | 112-00260 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m,-C | ||||||||
X66205-5-N-C | 112-00260 | Cable,Cntlr-Switch OM4,MPO/4x10G LC,5m,-C | ||||||||
X66250-15 | 112-00346 | Cable,LC-LC,OM4,15m | ||||||||
X66250-15-C | 112-00346 | Cable,LC-LC,OM4,15m,-C | ||||||||
X66250-15-N-C | 112-00346 | Cable,LC-LC,OM4,15m,-C | ||||||||
X66250-2 | 112-00342 | Cable,LC-LC,OM4,2m | ||||||||
X66250-2-C | 112-00342 | Cable,LC-LC,OM4,2m,-C | ||||||||
X66250-2-N-C | 112-00342 | Cable,LC-LC,OM4,2m,-C | ||||||||
X66250-30 | 112-00347 | Cable,LC-LC,OM4,30m | ||||||||
X66250-30-C | 112-00347 | Cable,LC-LC,OM4,30m,-C | ||||||||
X66250-30-N-C | 112-00347 | Cable,LC-LC,OM4,30m,-C | ||||||||
X66250-5 | 112-00344 | Cable,LC-LC,OM4,5m | ||||||||
X66250-5-C | 112-00344 | Cable,LC-LC,OM4,5m,-C | ||||||||
X66250-5-N-C | 112-00344 | Cable,LC-LC,OM4,5m,-C | ||||||||
Disk Drive Blank-Filler | ||||||||||
X5054-R6 | 108-00224 | BLANK,DSK DRV FILLER,DS2246,R6 | ||||||||
Drive | ||||||||||
X302A-R5 | 108-00268 | Disk Drive,1.0TB 7.2k,DS424x,FAS2240-4 | ||||||||
X306A-R5 | 108-00270 | Disk Drive,2.0TB 7.2k,DS424x,2554/2240-4 | ||||||||
X308A-R5 | 108-00277 | Disk Drive,3.0TB 7.2K,DS424x,2554/2240-4 | ||||||||
X309A-R6 [2] | 108-00301 | DSK DRV,3TB 7.2k,NSE,DS424x,FAS2220/2240-4 | ||||||||
X310A-R5 | 108-00235 | Disk Drive,500GB 7.2k SATA,DS4243 | ||||||||
X315A-R6 [2] | 108-00368 | DSK DRV,4TB 7.2k,NSE,DS424x,2554/2220/2240-4 | ||||||||
X316A-R6 | 108-00389 | Disk Drive,6TB 7.2k,DS4246,FAS2554 | ||||||||
X317A [2] | 108-00399 | DSK DRV,6TB,7.2K,12G,NSE,DS212C | ||||||||
X318A-R6 | 108-00455 | DSK DRV,8TB,7.2K,12G,DS212C | ||||||||
X319A | 108-00687 | SSD,7.6TB,12G,DS224C | ||||||||
X322A [2] | 108-00551 | DSK DRV,10TB,7.2K,12G,NSE,DS212C | ||||||||
X336A-R6 | 108-00427 | DSK DRV,4TB,7.2K,12G,DS212C | ||||||||
X339A | 108-00426 | DSK DRV,2TB,7.2K,12Gb,DS212C,FAS2620 | ||||||||
X341A-R6 | 108-00430 | DSK DRV,900GB,10K,12G,DS224C | ||||||||
X342A-R6 | 108-00432 | DSK DRV,1.2TB,10K,12G,DS224C | ||||||||
X343A-R6 | 108-00433 | DSK DRV,1.8TB,10K,12G,DS224C | ||||||||
X356A-R6 | 108-00468 | SSD,3.8TB,DS2246,FAS2552 | ||||||||
X357A | 108-00572 | SSD,3.8TB,12G,DS224C,W/MSW | ||||||||
X358A [2] | 108-00575 | SSD,3.8TB,12G,NSE,DS224C | ||||||||
X363A-R6 | 108-00467 | SSD,3.8TB,FAS2520/2554 | ||||||||
X364A | 108-00650 | SSD,3.8TB,DS212C,FAS2620,w/MSW | ||||||||
X365A-R6 [2] | 108-00477 | SSD,1.6TB,NSE,DS2246,FAS2552 | ||||||||
X366A-R6 [2] | 108-00470, 108-00478 | SSD,1.6TB,NSE,DS4246,FAS2554 | ||||||||
X371A | 108-00546 | SSD,960GB,12G,DS224C,W/MSW | ||||||||
X374A | 108-00573 | SSD,960GB,12G,DS212C,W/MSW | ||||||||
X380A | 108-00549 | DSK DRV,10TB,7.2K,12G,DS212C | ||||||||
X388A | 108-00885 | DSK DRV,16TB,7.2K,12G,DS212C | ||||||||
X410A-R5 | 108-00232 | Disk Drive,300GB 15k,DS424x | ||||||||
X411A-R5 | 108-00233 | Disk Drive,450GB 15k,DS424x | ||||||||
X412A-R5 | 108-00227 | Disk Drive,600GB 15k,DS424x | ||||||||
X414A-R5 [2] | 108-00159 | Disk Drive,600GB 15K,NSE,DS424x | ||||||||
X416A-R5 [2] | 108-00223 | Disk Drive,600GB 10k,NSE,DS224x,FAS2240-2 | ||||||||
X417A-R6 [2] | 108-00246 | DSK DRV,900GB,10K,NSE,DS2246,2552/2240-2 | ||||||||
X421A-R5 | 108-00220 | Disk Drive,450GB 10k,DS224x,FAS2240-2 | ||||||||
X422A-R5 | 108-00221 | Disk Drive,600GB 10k,DS224x,2552/2240-2 | ||||||||
X423A-R5 | 108-00222 | DSK DRV,900GB,10K,DS2246,2552/2240-2,R5 | ||||||||
X425A-R6 | 108-00321 | DSK DRV,1.2TB,10K,DS2246,2552/2240-2 | ||||||||
X426A-R6 | 108-00424 | DSK DRV,1.8TB,10K,DS2246,2552/2240-2 | ||||||||
X427A [2] | 108-00476 | DSK DRV,1.8TB,10k,NSE,DS2246,FAS2552 | ||||||||
X427B-R6 [2] | 108-00438 | DSK DRV,1.8TB,10K,12G,NSE,DS224C | ||||||||
X438A-R6 | 108-00369 | SSD,400GB,DS224x,FAS2552/2240-2 | ||||||||
X439A-R6 | 108-00372 | SSD,1.6TB,DS224x,FAS2552/2240-2 | ||||||||
X440A-R6 [2] | 108-00374 | SSD,800GB,NSE,DS224x,FAS2240-2,FAS2552 | ||||||||
X440B-R6 [2] | 108-00460 | SSD,800GB,12G,NSE,DS224C | ||||||||
X441A-R5 | 108-00278 | Solid State Drive,100GB,DS424x | ||||||||
X442A-R5 [3] | 108-00249 | Solid State Drive,100GB,3Gb,DS4243 | ||||||||
X446A-R6 | 108-00257 | SSD,200GB,DS224x,FAS2240-2 | ||||||||
X446B-R6 | 108-00323 | SSD,200GB,B,DS224x,FAS2240-2,FAS2552 | ||||||||
X447A-R6 | 108-00260 | SSD,800GB,DS224x,FAS2552/2240-2 | ||||||||
X448A-R6 | 108-00253 | SSD,200GB,DS4246,FAS2554/2240-4/2220 | ||||||||
X449A-R6 | 108-00319 | SSD,800GB,DS4246,FAS2554/2240-4/2220 | ||||||||
X477A-R6 | 108-00315 | DSK DRV,4TB 7.2k,DS4246,2554/2220/2240-4 | ||||||||
X488A-R5 | 108-00298 | Disk Drive,900GB 10K,2520/2220 | ||||||||
X489A-R6 | 108-00322 | Disk Drive,1.2TB 10K,2520/2220 | ||||||||
X490A-R6 | 108-00425 | Disk Drive,1.8TB 10K,FAS2520 | ||||||||
X575A-R6 | 108-00370 | SSD,400GB,DS424x,FAS2554/2240-4/2220 | ||||||||
X576A-R6 | 108-00373 | SSD,1.6TB,DS424x,FAS2554/2240-4/2220 | ||||||||
X577A-R6 [2] | 108-00375 | SSD,800GB,NSE,DS4246,FAS2554 | ||||||||
X670A | 108-00530 | SSD,15.3TB,12G,DS224C | ||||||||
Memory Module | ||||||||||
X3208A-R6 | 107-00100 | DIMM,4GB,Sys Memory,FAS2240,R6 | ||||||||
X3209A | 107-00099 | Controller,MEM,A400,8300 | ||||||||
X3209A-R6 | 107-00099 | DIMM,2GB,NVMEM,Sys Memory,FAS2240,R6 | ||||||||
Mezzanine Blank | ||||||||||
X1165A-R6 | 111-00813 | CARD Mezzanine Filler Blank,FAS2240,R6 | ||||||||
X1558A-R6-C | N/A | Jumper Crd,In-Cab,48-IN,C13-C14-C | ||||||||
X800-42U-35 | N/A | Jumper Crd,In-Cab,C13-C14,35-inch | ||||||||
X800-42U-35-C | N/A | Jumper Crd,In-Cab,C13-C14,35-inch,-C | ||||||||
X800-42U-35-K-N | N/A | Jumper Crd,In-Cab,C13-C14,35-inch | ||||||||
X800-42U-35-N | N/A | Power Cable,In-Cabinet,C13-C14,35-inch | ||||||||
X800-42U-43 | N/A | Jumper Crd,In-Cab,C13-C14,43-inch | ||||||||
X800-42U-43-C | N/A | Jumper Crd,In-Cab,C13-C14,43-inch,-C | ||||||||
X800-42U-43-K-N | N/A | Jumper Crd,In-Cab,C13-C14,43-inch | ||||||||
X800-42U-43-N | N/A | Power Cable,In-Cabinet,C13-C14,43-inch | ||||||||
X800-42U-64 | N/A | Jumper Crd,In-Cab,C13-C14,64-inch | ||||||||
X800-42U-64-C | N/A | Jumper Crd,In-Cab,C13-C14,64-inch,-C | ||||||||
X800-42U-64-K-N | N/A | Jumper Crd,In-Cab,C13-C14,64-inch | ||||||||
X800-42U-64-N | N/A | Power Cable,In-Cabinet,C13-C14,64-inch | ||||||||
X800-42U-R6 | N/A | Jumper Crd,In-Cab,C13-C14 | ||||||||
X800-42U-R6-C | N/A | Jumper Crd,In-Cab,C13-C14,-C | ||||||||
X800B-R6 | N/A | Power Cable,Continental Europe,R6 | ||||||||
X800B-R6-C | N/A | Power Cable,Continental Europe,-C,R6 | ||||||||
X800C-R6 | N/A | Power Cable,UK and Ireland,R6 | ||||||||
X800C-R6-C | N/A | Power Cable,UK and Ireland,-C,R6 | ||||||||
X800D-R6 | N/A | Power Cable,Japan,R6 | ||||||||
X800D-R6-C | N/A | Power Cable,Japan,-C,R6 | ||||||||
X800E-R6 | N/A | Power Cable,North America,R6 | ||||||||
X800E-R6-C | N/A | Power Cable,North America,-C,R6 | ||||||||
X800F-R6 | N/A | Power Cable,Australia/New Zealand,R6 | ||||||||
X800F-R6-C | N/A | Power Cable,Australia/New Zealand,-C,R6 | ||||||||
X800G-R6 | N/A | Power Cable,Switzerland,R6 | ||||||||
X800G-R6-C | N/A | Power Cable,Switzerland,-C,R6 | ||||||||
X800H-R6 | N/A | Power Cable,Argentina,R6 | ||||||||
X800H-R6-C | N/A | Power Cable,Argentina,-C,R6 | ||||||||
X800I-R6 | N/A | Power Cable,China,R6 | ||||||||
X800I-R6-C | N/A | Power Cable,China,-C,R6 | ||||||||
X800J-R6 | N/A | Power Cable,Denmark,R6 | ||||||||
X800J-R6-C | N/A | Power Cable,Denmark,-C,R6 | ||||||||
X800K-R6 | N/A | Power Cable,India,South Africa,R6 | ||||||||
X800K-R6-C | N/A | Power Cable,India,South Africa,-C,R6 | ||||||||
X800L-R6 | N/A | Power Cable,Israel,R6 | ||||||||
X800L-R6-C | N/A | Power Cable,Israel,-C,R6 | ||||||||
X800M-R6 | N/A | Power Cable,Italy,R6 | ||||||||
X800M-R6-C | N/A | Power Cable,Italy,-C,R6 | ||||||||
X800P-R6 | N/A | Power Cable,North America,250V,R6 | ||||||||
X800P-R6-C | N/A | Power Cable,North America,250V,-C,R6 | ||||||||
X800T-R6 | N/A | Power Cable,Taiwan,BSMI,R6 | ||||||||
X800T-R6-C | N/A | Power Cable,Taiwan,BSMI,-C,R6 | ||||||||
X800VB-R6 | N/A | Power Cable,Brazil,IEC-60906-1-Plug | ||||||||
X800W-R6 | N/A | Power Cable,Taiwan,250V,BSMI,R6 | ||||||||
X800W-R6-C | N/A | Power Cable,Taiwan,250V,BSMI,-C | ||||||||
X800Y-R6 | N/A | Power Cable,Japan,250V/15A | ||||||||
X800Y-R6-C | N/A | Power Cable,Japan,250V/15A,-C | ||||||||
Power Supply Unit | ||||||||||
X519A-R6 | 114-00065 | PSU W/FANS,750W,AC,DS2246,R6 | ||||||||
X523A-R6 | 114-00027 | PSU W/FANS,Estar,750W,AC,DS2246 | ||||||||
Processor Controller Module (PCM) | ||||||||||
X3245A-R6 | 111-00846 | FAS2220/2240,Controller,W/O MEM,W/O BATTERY | ||||||||
Transceiver | ||||||||||
X6589-N-C | 332-00279R6 | SFP+Optical 10Gb Shortwave,-C | ||||||||
X6589-R6 | 332-00279R6 | SFP+Optical 10Gb Shortwave | ||||||||
X6589-R6-C | 332-00279R6 | SFP+ Optical 10Gb Shortwave,-C | ||||||||
X6599A-N-C | 332-00363 | SFP+ Optical 10Gb Shortwave,-C | ||||||||
X6599A-R6 | 332-00363 | SFP+ Optical 10Gb Shortwave | ||||||||
X6599A-R6-C | 332-00363 | SFP+ Optical 10Gb Shortwave,-C | ||||||||
Footnote: | ||||||||||
[1] | Requires X6589-R6 SFP+ optical module or copper twinax cable. The X6589-R6 SFP+ module is optional and NOT included with the 10GbE mezzanine adapter by default. See Ethernet Ports Usage table for Cluster-Mode port assignment. | |||||||||
[2] | Mixing NSE drives or shelves with any other type of encrypting or non-encrypting drives or shelves across a stand-alone platform or high-availability (HA) pair is not supported. | |||||||||
[3] | This drive does not support the sanitization feature. |
Supported Firmware Matrix - FAS2240-2HA
Major OS Version | OS Version | Firmeware | |||||||
---|---|---|---|---|---|---|---|---|---|
BIOS | |||||||||
Clustered Data ONTAP 8.3 | 8.3.2, 8.3.2RC2, 8.3.1, 8.3.1RC1, 8.3, 8.3RC2, 8.3RC1 | 8.3* | |||||||
Clustered Data ONTAP 8.2 | 8.2.4, 8.2.3, 8.2.2 | 8.3 (7-Mode)*, 8.3*, 8.2, 8.1* | |||||||
Clustered Data ONTAP 8.2 | 8.2.2RC2, 8.2.2RC1 | 8.3 (7-Mode), 8.3, 8.2, 8.1* | |||||||
Clustered Data ONTAP 8.2 | 8.2.1 | 8.3 (7-Mode), 8.3, 8.2.0 (7-Mode), 8.2.0, 8.2*, 8.1* | |||||||
Clustered Data ONTAP 8.2 | 8.2.1RC2, 8.2.1RC1 | 8.3 (7-Mode), 8.3, 8.2.0 (7-Mode), 8.2.0, 8.2, 8.1* | |||||||
Clustered Data ONTAP 8.2 | 8.2, 8.2RC1 | 8.3 (7-Mode), 8.3, 8.2.0 (7-Mode), 8.2.0, 8.2, 8.1.0 (7-Mode), 8.1.0, 8.1* | |||||||
7-Mode 8.2 | 8.2.5P5 | 8.3 (7-Mode)* | |||||||
7-Mode 8.2 | 8.2.5 | 8.3 (7-Mode)*, 8.2, 8.1* | |||||||
7-Mode 8.2 | 8.2.4, 8.2.3, 8.2.2 | 8.3 (7-Mode)*, 8.3*, 8.2, 8.1* | |||||||
7-Mode 8.2 | 8.2.2RC2, 8.2.2RC1 | 8.3 (7-Mode), 8.3, 8.2, 8.1* | |||||||
7-Mode 8.2 | 8.2.1 | 8.3 (7-Mode), 8.3, 8.2.0 (7-Mode), 8.2.0, 8.2*, 8.1* | |||||||
7-Mode 8.2 | 8.2.1RC2, 8.2.1RC1 | 8.3 (7-Mode), 8.3, 8.2.0 (7-Mode), 8.2.0, 8.2, 8.1* | |||||||
7-Mode 8.2 | 8.2, 8.2RC1 | 8.3 (7-Mode), 8.3, 8.2.0 (7-Mode), 8.2.0, 8.2, 8.1.0 (7-Mode), 8.1.0, 8.1* | |||||||
ONTAP 9.1 | 9.1P17-P20, 9.1P13-P16, 9.1P10-P12, 9.1P9, 9.1P8, 9.1P3-P7, 9.1P1-P2, 9.1, 9.1RC2, 9.1RC1 | 8.3* | |||||||
Clustered Data ONTAP 8.1 | 8.1.4 | 8.3 (7-Mode), 8.3, 8.2.0 (7-Mode), 8.2.0, 8.2* | |||||||
Clustered Data ONTAP 8.1 | 8.1.3, 8.1.3RC1, 8.1.2, 8.1.2RC2, 8.1.1, 8.1.1RC1 | 8.3 (7-Mode), 8.3, 8.2.0 (7-Mode), 8.2.0, 8.1.0 (7-Mode), 8.1.0 | |||||||
Clustered Data ONTAP 8.1 | 8.1 | 8.3 (7-Mode), 8.3, 8.2.0 (7-Mode), 8.2.0, 8.1.0 (7-Mode), 8.1.0, 8.0.0 | |||||||
7-Mode 8.1 | 8.1.4 | 8.3 (7-Mode), 8.3, 8.2.0 (7-Mode), 8.2.0, 8.2* | |||||||
7-Mode 8.1 | 8.1.3, 8.1.3RC1, 8.1.2, 8.1.2RC2, 8.1.1, 8.1.1RC1 | 8.3 (7-Mode), 8.3, 8.2.0 (7-Mode), 8.2.0, 8.1.0 (7-Mode), 8.1.0 | |||||||
7-Mode 8.1 | 8.1 | 8.3 (7-Mode), 8.3, 8.2.0 (7-Mode), 8.2.0, 8.1.0 (7-Mode), 8.1.0, 8.0.0 | |||||||
ONTAP 9.0 | 9.0P1-P4, 9.0, 9.0RC2, 9.0RC1 | 8.3* | |||||||
Footnote: | |||||||||
[1]* Indicates that firmware is bundled with Storage OS Version |
Product Certificates - FAS2240-2HA
Certificate Name | Geo / Region / Country | Associated Products | |||||||
---|---|---|---|---|---|---|---|---|---|
Battery Pack safety reports | |||||||||
Lithium Battery Safety Doc-Section II/Section IB Shipments,Inventus Power Product Model#271-00029 | Global | Platforms : FAS2220, FAS2240-2, FAS2240-4, FAS2520, FAS2552, FAS2554 | |||||||
EMI and Safety certificates | |||||||||
Lithium Battery Safety Doc-Section II/Section IB Shipments,Inventus Power Product Model#271-00029 | Global | Platforms : FAS2220, FAS2240-2, FAS2240-4, FAS2520, FAS2552, FAS2554 | |||||||
Declaraion of Similarity NAJ-1001 | Global | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 G-K-U-SoR | Gabon,Kenya,SaudiArabia,Uganda | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 (FXN Mexico) BIS | BIS - India | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 (FXN Taiwan) BIS | BIS - India | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 ACMA | ACMA - Australia, New Zealand | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 BSMI | BSMI - Taiwan | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 CB | CB - International | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 CE | CE - European Union DoC | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 CSA | CSA - United States, Canada | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 EAC | EAC - Armenia, Belarus, Kazakhstan, Kyrgyzstan, Russia | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 IRAM | IRAM - Argentina | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 KC | KC - South Korea | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 Morocco | Morocco | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 NOM | NOM - Mexico | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 SONCAP | SONCAP - Nigeria | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 TBS | TBS - Tanzania | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 UKRSepro | UKRSepro - Ukraine | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001 VCCI | VCCI - Japan | Platforms : FAS2240-2, FAS2552 | |||||||
NAJ-1001_NRCS | NRCS - South Africa (Safety) | Platforms : FAS2240-2, FAS2552 | |||||||
Voluntary Product Accessibility Template | |||||||||
NAJ-1001_NRCS | NRCS - South Africa (Safety) | Platforms : FAS2240-2, FAS2552 |
Size, Weight, Acoustic, Power FAS2240-2HA
Associated Part No. | Configuration | Rack Units | Weight | Sound Power | Sound Pressure | Line Voltage Actual (Min to Max) | Amps Typical | Amps Worst | Watts Typical | Watts Worst | BTU / Hr Typical | BTU / Hr Worst |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Embedded Drive Config (Half) | ||||||||||||
FAS2240-2-12X450-2-R6 | FAS2240-2 1 PCM 12x450GB SAS | 2 | 451.9 lb (205.0 kg) | 69 Bels | 51 dBA | 100 (100 to 120) | 2.29 | 3.93 | 224 | 385 | 765 | 1314 |
FAS2240-2-12X450-2-R6 | FAS2240-2 1 PCM 12x450GB SAS | 2 | 451.9 lb (205.0 kg) | 69 Bels | 51 dBA | 200 (200 to 240) | 1.13 | 1.93 | 220 | 378 | 751 | 1291 |
FAS2240-2-12X450-2-R6 | FAS2240-2 2 PCM 12x450GB SAS | 2 | 50.0 lb (22.7 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.06 | 4.69 | 299 | 459 | 1021 | 1567 |
FAS2240-2-12X450-2-R6 | FAS2240-2 2 PCM 12x450GB SAS | 2 | 50.0 lb (22.7 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.5 | 2.3 | 294 | 450 | 1004 | 1536 |
FAS2240-2-12X600-2-R6 | FAS2240-2 1 PCM 12x600GB SAS | 2 | 45.2 lb (20.5 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 2.36 | 3.99 | 231 | 391 | 789 | 1335 |
FAS2240-2-12X600-2-R6 | FAS2240-2 1 PCM 12x600GB SAS | 2 | 45.2 lb (20.5 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.16 | 1.96 | 227 | 384 | 775 | 1311 |
FAS2240-2-12X600-2-R6 | FAS2240-2 2 PCM 12x600GB SAS | 2 | 50.0 lb (22.7 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.12 | 4.76 | 305 | 466 | 1041 | 1591 |
FAS2240-2-12X600-2-R6 | FAS2240-2 2 PCM 12x600GB SAS | 2 | 50.0 lb (22.7 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.53 | 2.34 | 299 | 457 | 1021 | 1560 |
FAS2240-2-12X900-2-R6 | FAS2240-2 1 PCM 12x900GB SAS | 2 | 45.2 lb (20.5 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 2.4 | 4.05 | 235 | 396 | 803 | 1352 |
FAS2240-2-12X900-2-R6 | FAS2240-2 1 PCM 12x900GB SAS | 2 | 45.2 lb (20.5 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.18 | 1.99 | 231 | 389 | 789 | 1328 |
FAS2240-2-12X900-2-R6 | FAS2240-2 2 PCM 12x900GB SAS | 2 | 50.0 lb (22.7 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.17 | 4.81 | 310 | 471 | 1058 | 1608 |
FAS2240-2-12X900-2-R6 | FAS2240-2 2 PCM 12x900GB SAS | 2 | 50.0 lb (22.7 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.56 | 2.36 | 304 | 462 | 1038 | 1577 |
Embedded Drive Config (Full) | ||||||||||||
F2240A-2-24X1.2TB-2-R6 | FAS2240-2 2 PCM 24x1.2TB | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.82 | 4.78 | 381 | 477 | 1302 | 1628 |
F2240A-2-24X1.2TB-2-R6 | FAS2240-2 2 PCM 24x1.2TB | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.92 | 2.36 | 373 | 462 | 1274 | 1580 |
F2240A-2-24X200-SSD-2-R6 | FAS2240-2 2 PCM 24x200GB | 2 | 55.3 lb (25.1 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 2.71 | 3 | 270 | 300 | 922 | 1024 |
F2240A-2-24X200-SSD-2-R6 | FAS2240-2 2 PCM 24x200GB | 2 | 55.3 lb (25.1 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.4 | 1.72 | 267 | 335 | 912 | 1144 |
F2240A-2-24X450-2-R6 | FAS2240-2 2 PCM no mezz 24x450GB | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.6 | 4.76 | 356 | 474 | 1215 | 1618 |
F2240A-2-24X450-2-R6 | FAS2240-2 2 PCM no mezz 24x450GB | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.76 | 2.31 | 339 | 456 | 1157 | 1557 |
F2240A-2-24X450-2-R6 | FAS2240-2 2 PCM no mezz 24x450GB | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 215 (200 to 240) | 1.64 | 2.15 | 336 | 456 | 1147 | 1557 |
F2240A-2-24X600-2-R6 | FAS2240-2 2 PCM no mezz 24x600GB | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.6 | 4.76 | 356 | 474 | 1215 | 1618 |
F2240A-2-24X600-2-R6 | FAS2240-2 2 PCM no mezz 24x600GB | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.76 | 2.31 | 339 | 456 | 1157 | 1557 |
F2240A-2-24X600-2-R6 | FAS2240-2 2 PCM no mezz 24x600GB | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 215 (200 to 240) | 1.64 | 2.15 | 336 | 456 | 1147 | 1557 |
F2240A-2-24X600N-2-R6 | FAS2240-2 2 PCM FC mezz 24x600GB | 2 | 56.0 lb (25.4 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.61 | 5.07 | 357 | 509 | 1219 | 1738 |
F2240A-2-24X600N-2-R6 | FAS2240-2 2 PCM FC mezz 24x600GB | 2 | 56.0 lb (25.4 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.78 | 2.47 | 340 | 487 | 1161 | 1663 |
F2240A-2-24X600N-2-R6 | FAS2240-2 2 PCM FC mezz 24x600GB | 2 | 56.0 lb (25.4 kg) | 6.9 Bels | 51 dBA | 215 (200 to 240) | 1.66 | 2.29 | 338 | 487 | 1154 | 1663 |
F2240A-2-24X600N-2-R6 | FAS2240-2 2 PCM no mezz 24x600GB | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.6 | 4.76 | 356 | 474 | 1215 | 1618 |
F2240A-2-24X600N-2-R6 | FAS2240-2 2 PCM no mezz 24x600GB | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.76 | 2.31 | 339 | 456 | 1157 | 1557 |
F2240A-2-24X600N-2-R6 | FAS2240-2 2 PCM no mezz 24x600GB | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 215 (200 to 240) | 1.64 | 2.15 | 336 | 456 | 1147 | 1557 |
F2240A-2-24X900-2-R6 | FAS2240-2 2 PCM 24x900GB | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.71 | 4.45 | 370 | 450 | 1263 | 1536 |
F2240A-2-24X900-2-R6 | FAS2240-2 2 PCM 24x900GB | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.88 | 2.23 | 360 | 420 | 1229 | 1434 |
F2240A-2-24X900N-2-R6 | FAS2240-2 2 PCM 24x900GB | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.71 | 4.45 | 370 | 450 | 1263 | 1536 |
F2240A-2-24X900N-2-R6 | FAS2240-2 2 PCM 24x900GB | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.88 | 2.23 | 360 | 420 | 1229 | 1434 |
Embedded Drive Config (Mixed) | ||||||||||||
F2240A-2-18TB-24M-2-R6 | FAS2240-2 2 PCM 4x200GB SSD 20x900GB HDD | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 100 (100 to 120) | 3.41 | 4.18 | 342 | 420 | 1168 | 1434 |
F2240A-2-18TB-24M-2-R6 | FAS2240-2 2 PCM 4x200GB SSD 20x900GB HDD | 2 | 55.6 lb (25.2 kg) | 6.9 Bels | 51 dBA | 200 (200 to 240) | 1.73 | 2.07 | 356 | 408 | 1215 | 1393 |