Base Standard Capabilities
Product features
Feature | Description |
---|---|
Chassis | The Apollo z70 chassis provides the following configuration:
Each HPE Apollo z70 chassis is built with the following:
|
Server | The HPE AR44z and AR64z servers provides the following:
|
System fans | The chassis ships standard with 8 single rotor fan modules |
Server tray blank kit | A chassis requires that four (4) server tray slots be populated with either an HPE AR44z or HPE AR64z or server node blank kit to allow adequate air flow |
Rack airflow requirements | The increasing power of new High-Performance processor technology requires increased cooling efficiency for Rack-Mounted servers. For maximum cooling, HPE racks are recommended to allow these racks to be fully loaded with servers using the latest processors. Check the below link for user guide on HPE Apollo z70 Chassis: CAUTION:
|
Bringing change and choice to the HPC community |
|
Designed from the ground up for HPC cluster deployments |
|
Quality and support expected from Hewlett Packard Enterprise design and manufacture |
|
Management features | IPMI 2.0 |
Memory | 16 Dual In-line Memory Module (DIMM) slots, 2666 MT/s, 512GB max (16 x 32GB) |
Physical specifications
Specifications | Description |
---|---|
Dimensions (H x W x D) | 8.73 x 44.81 x 89.37 cm (3.44 x 17.64 x 35.18 in) |
Shipping dimensions (H x W x D) | 31.75 x 60.02 x 95.9 cm (12.5 x 23.63 x 37.76 in) |
Chassis weight | 17.21 kg (37.94 lb) |
Maximum enclosure weight | 22.65 kg (49.93 lb) |
Form factor | 1U / 2U |
Environmental specifications
Specifications | Description |
---|---|
Temperature range | |
Operating | 10° to 35°C (50° to 95°F) |
Non-Operating | (-30°) to 60°C ((-22°) to 140°F) |
Relative humidity (Rh) | |
Operating | Minimum to be higher (More moisture) of - 12°C (10.4°F) dew point or 8% Rh |
Non-Operating | 5% to 95% Rh, 38.7°C (101.7°F) maximum wet bulb temperature, Non-Condensing |
NOTE: Operating temperature has an altitude derating of 1°C (1.8°F) per 304.8 m (1,000 ft). No direct sunlight. Upper operating limit is 3,048 m (10,000 ft) or 70 Kpa/10.1 psia. Upper Non-Operating limit is 9,144 m (30,000 ft) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage is 70 KPa |