Dell PERC 11 HBA350i SAS 12Gb LP HBA Controller

Thanks for the request. We'll get back to you with in 24 hours.

Condition: Refurbished ✓ Pulled from working servers & Tested. ✓ 1-year Parts Warranty.

Warranty | Return Policy

Quick Specs
  • Models: PCIe Host Bus Adapter
  • Drive Types: 12 Gb/s SAS, 6 Gb/s SAS/SATA, 3Gb/s SAS/SATA
  • PCI Support: PCI-e 4.0
  • SAS Connectors: 2x8 Internal
  • Cache Memory: N/A
  • Write Back Cache: N/A
  • RAID Levels: N/A
  • Max Drive Support: 16/controller, 50 with SAS Expander (Platform limit)
  • RAID Support: N/A
Part Number:
  • FH: NFYVN
The Dell HBA350i SAS 12Gb Adapter FH is a high-speed internal host bus adapter designed for enterprise environments requiring reliable SAS/SATA connectivity without RAID overhead. With support for PCI-e 4.0 and dual 2x8 internal connectors, it ensures fast and efficient data transfer.

Capable of managing up to 16 drives directly or up to 50 with a SAS expander, the HBA350i provides flexible, non-RAID storage scalability. It’s ideal for businesses seeking high-performance internal storage infrastructure with maximum throughput and simplified architecture.

Summary of RAID levels
Summary of RAID levels Following is a list of the RAID levels supported by the PERC 12 series of cards:
  • RAID 0

    Uses disk striping to provide high data throughput, especially for large files in an environment that requires no data redundancy.

  • RAID 1

    Uses disk mirroring so that data written to one physical disk is simultaneously written to another physical disk. RAID 1 is good for small databases or other applications that require small capacity and complete data redundancy.

  • RAID 5

    Uses disk striping and parity data across all physical disks (distributed parity) to provide high data throughput and data redundancy, especially for small random access.

  • RAID 6

    Is an extension of RAID 5 and uses an additional parity block. RAID 6 uses block-level striping with two parity blocks distributed across all member disks. RAID 6 provides protection against double disk failures, and failures while a single disk is rebuilding. If you are using only one array, deploying RAID 6 is more effective than deploying a hot spare disk.

  • RAID 10

    Is a combination of RAID 0 and RAID 1, uses disk striping across mirrored disks. It provides high data throughput and complete data redundancy.

  • RAID 50

    Is a combination of RAID 0 and RAID 5 where a RAID 0 array is striped across RAID 5 elements. RAID 50 requires at least six disks.

  • RAID 60

    Is a combination of RAID 0 and RAID 6 where a RAID 0 array is striped across RAID 6 elements. RAID 60 requires at least eight disks.

Compatible With:
  • Dell R440
  • Dell R540
  • Dell R740xd
  • Dell R940xa

(Click to View)