Current Configuration

(List below serves as quick links to each section)

Server Chassis

HPE Processors

Heat Sinks

HPE Memory v3

HPE Memory v4

HPE Ethernet Mezzanine Cards

HPE FlexibleLOM Adapters

HPE SATA Drives

HPE SAS Drives

HPE NVMe Drive

M.2 enablement kit

Storage controller / NVMe pass-through board

HPE Server Management

Trusted Platform Module (TPM)

ESC Warranty

The request has been sent.
Thank you.

Price as Configured:
$0

Add to Cart

Error Submitting Cart. Please get in touch with us for support.

Please select all the mandatory items in the configuration list before submitting the cart.

One or more items in your cart has no price. This will be submitted as a "Request for a Quote".

HPE ProLiant BL660c Blade Server (G9) CTO

HPE

| CTO Servers |

HPE-BL660C-G9-CTO

 

Multi-Quantity Discounts Available for ALL Line Items

** LARGE DISCOUNTS available for complete systems. Pricing displayed is for single item purchases **

Use the configuration tool to create your solution and submit it us for a quote OR send us a message with your complete build requirements to receive best pricing

READ ME

  • Some options may not be displayed until the compatible parent option is chosen ie. Chassis – Drives, Processor – RAM etc.
  • “Quote” items can be added to your cart and sent to us via the cart page
  • Click the blue bar to close/open a section from view after choosing your options

Server Chassis

HPE Processors

2 Socket and 4 Socket configurations are supported

Intel Xeon E5-4600 v3

Supports up to (4) processors
Supported Configurations are 2 and 4 sockets. 1 and 3 socket configurations are not supported
You must also select Heatsinks for each processor.

Intel Xeon E5-4600 v4

Supports up to (4) processors
Each Processor kit hold (2) Proccessors with Heatsinks

Heat Sinks (Optional)

Supports up to 4 Heat Sinks.
If you only install 2 CPUS please install 2 Blanks.
This server can only be configured with 2 or 4 Processors. 1 and 3 Processor configurations are not supported.

HPE Memory v3 (Optional)

Supports up to 32 DIMMS
LRDIMM and RDIMM are distinct memory technologies and cannot be mixed within a server.

HPE Memory v4 (Optional)

Supports up to 32 DIMMS
LRDIMM and RDIMM are distinct memory technologies and cannot be mixed within a server.

HPE Ethernet Mezzanine Cards (Optional)

Supports up to (3) Mezzanine cards on a (2 or 4) socket configuration
3 Mezzanine Slots (1) Type A and (2) Type A or Type B
The FDR InfiniBand adapter must be installed in mezzanine slot 1 for FDR mode and may be installed in either mezzanine slot if operated in any other mode.
When an InfiniBand adapter is installed in mezzanine slot 1, only one port is active (regardless of operating mode). When installed in mezzanine slot 2, both ports are active.

HPE FlexibleLOM Adapters (Optional)

Supports up to (2)

HPE SATA Drives (Optional)

Supports up to (4) Drives
HPE drives from generation G7 servers and before are not compatible
The mixing of standard SAS drives with SAS SSD is supported within the server, but limits the RAID configuration to two separate RAID 0 volumes. Mixing of other drives types is not supported.

HPE SAS Drives (Optional)

Supports up to (4) Drives
HPE drives from generation G7 servers and before are not compatible
The mixing of standard SAS drives with SAS SSD is supported within the server, but limits the RAID configuration to two separate RAID 0 volumes. Mixing of other drives types is not supported.

HPE NVMe Drive (Optional)

A maximum of two (2) NVMe drives are supported on the BL660c Gen9. When using these drives, the other two drive bays must remain unused.
The NVMe Pass-Through Storage Controller is required to support the NVMe drives
The HPE Gen9 Broadwell NVMe FIO Setting (825555-B21) is required to support up to 2 SFF NVMe SSDs within the system.
NVME FIO Setting is not compatible with the HPE Smart Array P246br.
HPE recommends the use of a dual M.2 solid state drive kit for boot when using this NVME FIO Setting.

M.2 enablement kit (Optional)

If you do not have the riser board you need to install the option with the Enablement Kit as well.
Supports up to (2) M.2 Drives

Storage controller / NVMe pass-through board (Optional)

The HPE Smart Array B140i Controller (chipset SATA) comes standard. If the HPE Smart Array P246br controller is not chosen, SATA cables will be provided to support SATA devices for the four internal drives. If RAID is required when using the B140i, please choose ‘HPE FIO B140i RAID Enable Kit - BIOS Setting’ (784308-B21).

HPE Server Management (Optional)

HPE iLO Management (standard)

Trusted Platform Module (TPM) (Optional)

The TPM key is unique to every TPM deployed server and must be retained. Misplacing or losing the key could result in data loss.

ESC Warranty

Helpful Tip: Once desired configuration is selected click "Add to Cart".
From the cart page you can submit a submit a quote request for best pricing

-PLEASE CONTACT FOR CUSTOM CONFIGURATIONS. DISK SHELVES, COMPLETE CONFIGURATIONS & TURN KEY SYSTEMS AVAILABLE.

-SPARE PARTS AVAILABLE FOR EACH MODEL. PLEASE ASK FOR PRICING ON SPARE DISK, CONTROLLERS, POWER SUPPLIES, NICs, HBAs, SFPs, Cables, etc.

Quick Specs

What's New for BL660c (G9)
  • E5-4600 v4 Intel Xeon processors and HPE 2400MT/s DDR4 SmartMemory.
  • Support for 2 NVMe SSDs for high performance caching
  • Optional 120GB dual M.2 kit
  • Support for 2400 MT/s DDR4 memory
  • HPE PCIe Workload Accelerators for up to 3.2TB of flash based cache
  • 4 SFF Drive bays
  • Upto 4 SFF drives, internal USB 3.0, optional dual micro-SD, and optional M.2 support deliver a variety of system boot options.

The HP ProLiant BL660c (G9) scales workloads and infrastructure without compromise. Designed to deliver a balance of performance, scalability, and manageability, it delivers outstanding cost and accelerated time to value for data centers.


Ideal for:

  • Cloud Servers
  • Corporate IT
  • Database
  • Retail Servers

This blade is ideal for workloads that require a fine-tuned balance between space, price, and performance—such as database, virtualization, business processing, analytics, HPC, and other data-intensive applications.


CTO Configuration Support

Need help with the configuration? Contact us today!

ChassisYou have the choice of 4 CTO Chassis. They are split up for Processor and Drive reasons. Since this system can handle Intel Xeon e5-4600 V3 (759483-001) and V4 (858552-001 ). Both go on their own System board which can handle certain Memory DIMM speeds. The Chassis are also broken out into Drive Type. This system has two different backplanes to be installed on the drive cages. The SAS/SATA backplane (795117-001) and the NVMe backplane (744413-001 ). Below are more details into each type.


NVMe Drives
You must select the NVMe chassis, this has the NVMe backplane installed on it. You must also select the NVMe Pass-through controller along with the HPE BL460c G9 Broadwell NVMe FIO Setting (825555-B21) . This FIO option disables SFF bays 3 and 4 and is not compatible with the HPE Smart Array P246br. Hewlett Packard Enterprise recommends the use of a dual M.2 solid state drive kit for boot when using this option. Once all of these are selected you can only choose up to (2) NVMe SSD Drives. When these Drives are installed the other two drive bays are non-functional and blanks will cover them.


SAS/SATA Drives
This server comes standard with the B140i Controller. This controller only supports SATA drives. If the HPE Smart Array P244br SAS Controller is not selected then 2 SATA cables will need to be installed. If you want to have RAID enabled while using Factory Standard B140i you'll also need to install the HPE FIO B140i SW RAID Enablement Kit (784308-B21).

For SAS Drives the HPE Smart Array P246br/1GB FBWC 12Gb 4 - ports Int SAS Controller (726793-B21) along with SAS cables will enable this server to run 4 SAS Drives.


HPE iLO Management (standard)Monitor your servers for ongoing management, service alerting, reporting and remote management with iLO. Configure and boot your servers securely with industry standard Unified Extensible Firmware Interface (UEFI).

Server Utilities

HPE Smart Update - Optimize firmware and driver updates with HPE Smart Update solutions. HPE OneView Standard - HPE OneView Standard can inventory, monitor, alert, and report on your G6 thru (G9) servers, with use of the REST API and HPE OneView user interface.


Mezzanine Adapters

Up to three (3) optional Fibre Channel mezzanine HBAs and (2) FlexibleLOMs providing four Ethernet ports are supported on the HPE ProLiant BL660c (G9).


When an InfiniBand adapter is installed in mezzanine slot 1, only one port is active (regardless of operating mode). When installed in any other mezzanine slot, both ports are active. The FDR InfiniBand adapter must be installed in mezzanine slot 1 for FDR mode and may be installed in any mezzanine slot if operated in any other mode. Optional dual-port Fibre Channel mezzanine card(s) for redundant SAN connections.